apoptosis detection Apoptosis assays for the Attune Acoustic Focusing Cytometer Apoptosis detection Attune Acoustic Focusing Cytometer



Similar documents
Annexin V Conjugates for Apoptosis Detection

FITC Annexin V/Dead Cell Apoptosis Kit with FITC annexin V and PI, for Flow Cytometry

Annexin V-EGFP Apoptosis Detection Kit

Annexin V-FITC Apoptosis Detection Kit

Islet Viability Assessment by Single Cell Flow Cytometry

Annexin V-FITC Apoptosis Detection Kit

use. 3,5 Apoptosis Viability Titration Assays

FlowSight. Flow cytometry with vision

Cell Viability Measurement

Flow Cytometry. flow cytometer DNA apoptosis ph

Cell Cycle Tutorial. Contents

Comparison of Trypan Blue and Fluorescence-Based Viability Detection Methods Via Morphological Observation

ab Propidium Iodide Flow Cytometry Kit for Cell Cycle Analysis

ArC Amine Reactive Compensation Bead Kit

EdU Flow Cytometry Kit. User Manual

Introduction to flow cytometry

Immunophenotyping peripheral blood cells

123count ebeads Catalog Number: Also known as: Absolute cell count beads GPR: General Purpose Reagents. For Laboratory Use.

No-wash, no-lyse detection of leukocytes in human whole blood on the Attune NxT Flow Cytometer

Cell Viability Assays: Microtitration (MTT) Viability Test Live/Dead Fluorescence Assay. Proliferation Assay: Anti-PCNA Staining

Uses of Flow Cytometry

Boundary-breaking acoustic focusing cytometry

Real-time PCR: Understanding C t

Knipholone anthrone from Kniphofia foliosa induces a rapid onset of necrotic cell death in cancer cells

15.5 Assays for Apoptosis

Flow Cytometry. What is Flow Cytometry? What Can a Flow Cytometer Tell Us About a Cell? Particle Size. Flow = Fluid Cyto = Cell Metry = Measurement

Labeling and Detection. The best and brightest Alexa Fluor dyes

COMPENSATION MIT Flow Cytometry Core Facility

Application Note. Selecting Reagents for Multicolor Flow Cytometry. Holden Maecker and Joe Trotter BD Biosciences, San Jose

Cell Cycle Phase Determination Kit

Bottlenecks in Clinical Source Material Acquisition. Aby J. Mathew, PhD May 5, 2009 ISCT Annual Meeting San Diego, CA

LIVE/DEAD Fixable Dead Cell Stain Kits

Multicolor Flow Cytometry: Setup and Optimization on the BD Accuri C6 Flow Cytometer

Standard Operating Procedure

Flow cytometric Annexin V/Propidium Iodide measurement in A549 cells

a Beckman Coulter Life Sciences: White Paper

Cytell Cell Imaging System

FLOW CYTOMETRY: PRINCIPLES AND APPLICATIONS. By: Douaa Moh. Sayed

Measuring Cell Viability/Cytotoxicity: Cell Counting Kit-F

Introduction to Flow Cytometry

CFSE Cell Division Assay Kit

2.500 Threshold e Threshold. Exponential phase. Cycle Number

APPLICATION INFORMATION

MEASURABLE PARAMETERS: Flow cytometers are capable of measuring a variety of cellular characteristics such as:

Labeling Antibodies & Biopolymers

Living and Dead Cells Staining: -Cellstain- Double Staining Kit

Application Note No. 2 / July Quantitative Assessment of Cell Quality, Viability and Proliferation. System

Katharina Lückerath (AG Dr. Martin Zörnig) adapted from Dr. Jörg Hildmann BD Biosciences,Customer Service

CyFlow SL. Microbiology. Detection and Analysis of Microorganisms and Small Particles

protocol handbook 3D cell culture mimsys G hydrogel

Zecotek S Light Projection Network Marketing

Selected Topics in Electrical Engineering: Flow Cytometry Data Analysis

Supplementary Material. Free-radical production after post-thaw incubation of ram spermatozoa is related to decreased in vivo fertility

Goat Anti Mouse IgG Antibodies

7.1 A Wide Variety of Protein Conjugates

Fluorescent dyes for use with the

Introduction to Flow Cytometry -- BD LSR II. What is Flow Cytometry? What Can a Flow Cytometer Tell Us About a Cell? Particle Size

Incorporation of a Novel 3D Cell Culture System to Perform in vitro Cytotoxicity Analyses using Human Primary Hepatocytes

Goat Anti Rabbit IgG Antibodies

PROTOCOL. Immunostaining for Flow Cytometry. Background. Materials and equipment required.

Technical Note. Roche Applied Science. No. LC 19/2004. Color Compensation

SmartFlare RNA Detection Probes: Principles, protocols and troubleshooting

MitoPT JC-1 Mitochondrial Permeability Transition Detection Kits MitoPT JC Test Kit catalog # 924 MitoPT JC Test Kit catalog # 911

CyTOF2. Mass cytometry system. Unveil new cell types and function with high-parameter protein detection

Cell, Tissue and Tumor Kinetics

Assays for Cell Viability, Proliferation and Function

Analysis of Apoptosis by Flow-cytometry

MTT Cell Proliferation Assay

Using the BD TM Cytometer Setup and Tracking (CS&T) System for Instrument Characterization and Performance Tracking

Below is a list of things you should be aware of before you schedule your sort.

Hoechst HSC Staining and Stem Cell Purification Protocol (see Goodell, M., et al. (1996) J Exp Med 183, )

Technical Bulletin. An Introduction to Compensation for Multicolor Assays on Digital Flow Cytometers

The use of FACS for the selection of cell lines with superior productivity characteristics

Advantages of the Alexa Fluor 488 secondary antibody conjugates

FCAP Array v3.0 Software: A New Tool to Analyze BD Cytometric Bead Array (CBA) Data. Monisha Sundarrajan, PhD BD Biosciences

Compensation in Flow Cytometry

Application Information Bulletin: Set-Up of the CytoFLEX Set-Up of the CytoFLEX* for Extracellular Vesicle Measurement

CellTiter-Fluor Cell Viability Assay

Transfection reagent for visualizing lipofection with DNA. For ordering information, MSDS, publications and application notes see

CyAn : 11 Parameter Desktop Flow Cytometer

Cell counting, viability and proliferation

Chapter 10 Immunofluorescence

AP Bio Photosynthesis & Respiration

Protein extraction from Tissues and Cultured Cells using Bioruptor Standard & Plus

NyONE - Cell imaging in a bird s eye view 4. NyONE...resolution matters! 8. Features & benefits 10. Fluorescence excitation channels 12

ab Protein Sumoylation Assay Ultra Kit

Flow Data Analysis. Qianjun Zhang Application Scientist, Tree Star Inc. Oregon, USA FLOWJO CYTOMETRY DATA ANALYSIS SOFTWARE

WESTERN BLOT DETECTION KIT Buffers and detection reagents for up to ten 10 x 10 cm 2 blots. Fluorescent detection via: Goat anti-mouse SureLight P3

International Beryllium Conference, Montreal, Canada March 10, 2005

Introduction to Flow Cytometry

FluorChem Q. A Quantitative Western Blot Imaging Solution

Principles of Flowcytometry

Products - Microarray Scanners - SpotLight Two-Color Microarray Fluorescence Scanners New! SpotLight 2 now available!

ab FITC Conjugation Kit Protocol

powerful. Intuitive. Customizable. The new star of benchtop flow cytometry

FluoProbes dyes. FluoProbes dyes directly conjugated to secondary antibodies

PROTOCOL. Immunocytochemistry (ICC) MATERIALS AND EQUIPMENT REQUIRED

RayBio Creatine Kinase (CK) Activity Colorimetric Assay Kit

Results: A plot showing propidium iodide and Annexin is used to determine apoptotic (Annexin only +) from necrotic (PI+ and Annexin +).

CRITICAL ASPECTS OF STAINING FOR FLOW CYTOMETRY

Transcription:

apoptosis detection ttune coustic Focusing Cytometer poptosis detection poptosis assays for the ttune coustic Focusing Cytometer poptosis is a carefully regulated process of cell death that occurs as a normal part of development. poptosis is distinguished from necrosis, or accidental cell death, by characteristic morphological and biochemical changes, including compaction and fragmentation of nuclear chromatin, shrinkage of the cytoplasm, and loss of membrane asymmetry. iochemically, apoptosis is distinguished by fragmentation of the genome and cleavage or degradation of several cellular proteins. s with cell viability, no single parameter fully defines cell death in all systems; therefore, it is often advantageous to use several different approaches when studying apoptosis [1 4]. ife Technologies provides a broad offering of research reagents and kits for apoptosis testing for use with flow cytometry. Here, our most popular kits are demonstrated on the ttune coustic Focusing Cytometer three apoptotic plasma membrane assays and a mitochondrial membrane potential assay. coustic cytometry is compatible with our full range of apoptosis products. poptotic plasma membrane assays for flow cytometry Some of the earliest detectable apoptotic events involve the plasma membrane, including changes in membrane asymmetry and permeability. In addition to annexin V conjugates, ife Technologies provides unique assays to measure membrane changes under conditions where annexin V binding is problematic, such as in adherent cells, and without using special buffers. nnexin V conjugates In apoptotic cells, phosphatidylserine (PS) is translocated from the inner to the outer leaflet of the plasma membrane, thus exposing PS to the external cellular environment. nnexin V labeled with a fluorophore can identify apoptotic cells by binding to PS exposed on the outer leaflet of the membrane. The lexa Fluor series of dyes, used in our nnexin V ead Cell poptosis kits (Figure 1), has proven to make brighter and more photostable bioconjugates than other organic dyes with similar spectral characteristics. Propidium iodide fluorescence Untreated Jurket cells lexa Fluor 488 nnexin V fluorescence Treated Jurket cells lexa Fluor 488 nnexin V fluorescence Figure 1. poptosis detection with the nnexin V ead Cell poptosis Kit. Jurkat cells (T-cell leukemia, human) treated with 10 μm camptothecin for 4 hr () or untreated control (). Cells were stained using the nnexin V ead Cell poptosis Kit and analyzed by flow cytometry with 488 nm excitation on the ttune coustic Focusing Cytometer with 530/30 nm and 575/24 nm bandpass filters. ata were acquired with a standard 100 μ/min collection rate. Note that the camptothecin-treated cells () have a higher percentage of apoptotic cells than the basal level of apoptosis seen in the control cells (). = apoptotic cells, V = viable cells, N = necrotic cells. Propidium iodide fluorescence

Monomeric cyanine dyes There are some situations in which staining cells with annexin V is not the optimal method for detecting apoptosis. These include assays where cells are sensitive to the high calcium concentrations required for annexin V binding, assays where phosphatidylserine detection on adherent cells is adversely affected by trypsinization, and assays where washing of samples is prohibitive. propidium iodide fluorescence Yo-pRo -1 fluorescence Figure 2. poptosis detection using YO-PRO -1 stain. Jurkat cells (human T-cell leukemia) were treated for 4 hr with 10 μm camptothecin. Cells were then stained with 1.5 μm propidium iodide (PI) and 0.1 μm YO-PRO -1 dye and analyzed on the ttune coustic Focusing Cytometer using 488 nm excitation. YO-PRO -1 dye fluorescence was collected with a 530/30 nm bandpass filter and PI fluorescence was collected with a 575/24 nm bandpass filter. Populations are labeled as = live cells, = apoptotic cells, and = dead cells. Three monomeric cyanine dyes (PO-PRO -1, YO-PRO -1, and TO-PRO -3) (Figures 2 and 3) have been shown to penetrate apoptotic cells because of permeability changes associated with the loss in asymmetry of the plasma membrane [5]. These dyes enter apoptotic cells and bind to nucleic acids, while cell-impermeant dead cell stains are excluded. The three dyes have unique excitation wavelengths, providing enhanced flexibility in multiplexed assays. 7-aad fluorescence po-pro -1 dye fluorescence Figure 3. poptosis detection using PO-PRO -1 stain. Jurkat cells (human T-cell leukemia) were treated for 4 hr with 10 μm camptothecin. Cells were then stained with 1.5 μm 7- and 0.1 μm PO-PRO -1 dye and analyzed on the ttune coustic Focusing Cytometer using 405 nm and 488 nm excitation. PO-PRO -1 dye fluorescence was collected with a 450/40 nm bandpass filter and 7- fluorescence was collected with a 640 nm longpass filter. Populations are colored as green = live cells, blue = apoptotic cells, and red = dead cells.

JC-1 red fluorescence - -3 JC-1 red fluorescence - -3 Violet Ratiometric Membrane symmetry Probe/ead Cell poptosis Kit The Violet Ratiometric Membrane symmetry Probe/ead Cell poptosis Kit (Figure 4) provides a simple and fast method for detecting apoptosis with dead-cell discrimination by flow cytometry. The violet ratiometric membrane asymmetry probe F2N12S (4 -N,N-diethylamino-6-(Ndodecyl-N-methyl-N-(3-sulfopropyl)) ammoniomethyl-3-hydroxyflavone) is a novel violet diode excitable dye for the detection of membrane phospholipid asymmetry changes during apoptosis. This dye exhibits an excited-state intramolecular proton transfer (ESIPT) reaction, resulting in dual fluorescence with two emission bands corresponding to 530 nm and 585 nm and producing a two-color ratiometric response to variations in surface charge [6]. This ratiometric probe is therefore a self-calibrating absolute parameter of apoptotic transformation, independent of probe concentration, cell size, and instrument variations. Mitochondrial JC-1 apoptosis assay for flow cytometry distinctive feature of the early stages of apoptosis is the disruption of the mitochondria, including changes in membrane and redox potential [7 9]. ife Technologies exclusively offers a number of fluorescent probes for analyzing mitochondrial activity in live cells by flow cytometry the MitoProbe assays. The JC-1 dye (Figure 5) exhibits potential-dependent accumulation in mitochondria, indicated by a fluorescence emission shift from green (~529 nm) to red (~590 nm). Consequently, mitochondrial depolarization is indicated by a decrease in the red/green fluorescence intensity ratio, which is dependent only on the membrane potential and not on other factors such as mitochondrial size, shape, and density, which may influence single-component fluorescence measurements. F2n12s green fluorescence V2-H ( ) C sytox aadvanced fluorescence 3-H ( ) 1.4 1.2 1.0 0.8 0.6 0.4 0.2 + 0.0 0.0 0.5 1.0 1.5 2.0 0 1,000 2,000 3,000 4,000 5,000 JC-1 Jc-1 green fluorescence -- 1-H Jc-1 JC-1 green fluorescence - - 1-H Figure 5. Jurkat cells stained with 2 μm JC-1. Cells were stained for 20 min at 37ºC and Figure 5. Jurkat cells stained with 2 μm JC-1. Cells were stained for 20 min at 37 C and 5% CO 2, washed with PS, and analyzed on the ttune coustic Focusing Cytometer using 488 nm excitation with 530/30 nm bandpass and >640 longpass emission filters. Untreated cultured cells () are shown compared to treated cells (), which were induced to undergo apoptosis with 10 μm camptothecin for 5 hr at 37ºC. 1.4 1.2 1.0 0.8 0.6 0.4 0.2 + 0.0 0.0 0.5 1.0 1.5 2.0 F2n12s orange fluorescence V3-H ( ) F2n12s orange fluorescence V3-H ( ) 0 1,000 2,000 3,000 4,000 5,000 Figure 4. The Violet Ratiometric Membrane symmetry Probe/ead Cell poptosis Kit. Jurkat cells (T-cell leukemia, human) were treated with 10 μm camptothecin for 4 hr ( and ) or left untreated ( and C). Cells were stained according to the protocol and analyzed on the ttune coustic Focusing Cytometer. For F2N12S, 405 nm excitation and 522/31 nm and 603/48 nm bandpass filters were used; for SYTOX vanced dead cell stain, 488 nm excitation and a 640 nm longpass filter was used. In panels and, live cells can be discriminated from apoptotic and dead cells by the relative intensities of the two emission bands from F2N12S. In panels C and, SYTOX vanced dead cell stain fluorescence is plotted against a derived ratio parameter from the two emission bands (585/530 nm) of F2N12S. = apoptotic cells, = live cells, = dead cells. Jc-1 red fluorescence - -3 F2n12s Ratio 585 nm/530 nm fluorescence x 1000 V3-H/V2-H Untreated F2n12s green fluorescence V2-H ( ) sytox aadvanced fluorescence 3-H ( ) Jc-1 red fluorescence - -3 F2n12s Ratio 585 nm/530 nm fluorescence x 1000 V3-H/V2-H treated

Ordering Information Current prices may be obtained from our website or by contacting Customer Service. Product Quantity Cat. No. lexa Fluor 488 nnexin V/ead Cell poptosis Kit with lexa Fluor 488 nnexin V and PI (for flow cytometry) 1 kit (50 assays) V13241 lexa Fluor 488 nnexin V/ead Cell poptosis Kit with lexa Fluor 488 nnexin V and PI (for flow cytometry) 1 kit (250 assays) V13245 Membrane Permeability/ead Cell poptosis Kit with YO-PRO -1 and PI (for flow cytometry) 1 kit (200 assays) V13243 Membrane Permeability/ead Cell poptosis Kit with PO-PRO -1 and 7-aminoactinomycin (for flow cytometry) 1 kit (200 assays) V35123 Violet Ratiometric Membrane symmetry Probe/ead Cell poptosis Kit (for flow cytometry) 1 kit (100 assays) 35137 MitoProbe JC-1 ssay Kit 1 kit (100 assays) M34152 Related Products (these products are compatible with the ttune coustic Cytometer and the performance will be similar to the results shown on the previous pages) Product Quantity Cat. No. Single Channel nnexin V/ ead Cell poptosis Kit (lexa Fluor 488 nnexin V/SYTOX Green) (for flow cytometry) 1 kit (50 assays) V13240 nnexin-binding buffer (5X concentrate) (for flow cytometry) 50 m V13246 PE nnexin V/ ead Cell poptosis Kit (with SYTOX Green) (for flow cytometry) 1 kit (50 assays) V35112 Violet nnexin V/ead Cell poptosis Kit (Pacific lue nnexin V/SYTOX vanced ) (for flow cytometry) 1 kit (50 assays) V35136 nnexin V, lexa Fluor 350 conjugate 100 assays 23202 nnexin V, lexa Fluor 488 conjugate 100 assays 13201 nnexin V, lexa Fluor 555 conjugate 100 assays 35108 nnexin V, lexa Fluor 568 conjugate 100 assays 13202 nnexin V, lexa Fluor 594 conjugate 100 assays 13203 nnexin V, lexa Fluor 647 conjugate 100 assays 23204 nnexin V, lexa Fluor 680 conjugate 100 assays 35109 nnexin V, allophycocyanin conjugate (PC nnexin V) 50 assays 35110 nnexin V, biotin-x conjugate 100 assays 13204 nnexin V, fluorescein conjugate (FITC nnexin V) 100 assays 13199 nnexin V, Oregon Green 488 conjugate 100 assays 13200 nnexin V, R-phycoerythrin conjugate (R-PE nnexin V) 50 assays 35111 nnexin V, Pacific lue conjugate (for flow cytometry) 100 assays 35122 PO-PRO -1 iodide (435/455) (1 mm solution in MSO) 1 m P3581 YO-PRO -1 iodide (491/509) (1 mm solution in MSO) 1 m Y3603 TO-PRO -3 iodide (642/661) (1 mm solution in MSO) 1 m T3605 MitoProbe ioc 2 (3) (for flow cytometry) 100 assays M34150 MitoProbe iic 1 (5) ssay Kit (for flow cytometry) 100 assays M34151 MitoTracker Orange CMTMRos (special packaging) 20 50 μg M7510 MitoTracker Red CMXRos (special packaging) 20 50 μg M7512 MitoProbe Transition Pore ssay Kit (for flow cytometry) 100 assays M34153 Vybrant FM Poly Caspases ssay Kit (for flow cytometry) 1 kit V35117 Vybrant FM Caspase-3 and -7 ssay Kit (for flow cytometry) 1 kit V35118 Vybrant FM Caspase-8 ssay Kit (for flow cytometry) 1 kit V35119 nti-prp FITC poptosis Kit 1 kit HM2011 Hoechst 33342 100 mg H1399 Vybrant yecycle Violet stain (5 mm solution in MSO) 200 assays V35003 PO-rdU TUNE ssay Kit (with lexa Fluor 488 anti-rdu) 60 assays 23210

FITC nnexin V/ead Cell poptosis Kit with FITC nnexin V and PI (flow cytometry) 50 assays V13242 Chromatin Condensation/ead Cell poptosis Kit with Hoechst 33342 and PI (for flow cytometry) 200 assays V13244 Chromatin Condensation/Membrane Permeability/ead Cell poptosis Kit with Hoechst 33342/YO-PRO -1 200 assays V23201 and PI (flow cytometry) PC nnexin V/ead Cell poptosis Kit with PC nnexin V and SYTOX Green (for flow cytometry) 50 assays V35113 Metabolic ctivity/nnexin V/ead Cell poptosis Kit with C 12 Resazurin, PC nnexin V, and SYTOX 50 assays V35114 Green (flow cytometry) Mitochondrial Membrane Potential/nnexin V poptosis Kit with MitoTracker Red and lexa Fluor 488 50 assays V35116 nnexin V (flow cytometry) Violet nnexin V/ead Cell poptosis Kit with Pacific lue nnexin V/SYTOX vanced (for flow cytometry) 50 assays 35136 Violet Chromatin Condensation/ead Cell poptosis Kit with Vybrant yecycle Violet and SYTOX 200 assays 35135 vanced (for flow cytometry) References 1. poptosis (2007) 12:803 813. 2. Cell eath iffer (2009) 16:3 11. 3. Methods Mol iol (2009) 559:19 32. 4. Methods (2008) 44:222 228. 5. J Immunol Meth 185:249 258. 6. J m Chem Soc (2007) 129:2187 2193. 7. Trends Cell iol (2000) 10:369 377. 8. Science (2000) 289:1150 1151. 9. Science (2001) 292:624 626. ife Technologies offers a breadth of products N RN protein cell culture instruments For Research Use Only. Not intended for any animal or human therapeutic or diagnostic use. 2011 ife Technologies Corporation. ll rights reserved. The trademarks mentioned herein are the property of ife Technologies Corporation or their respective owners. Printed in the US. CO23104 0611