Flow Data Analysis. Qianjun Zhang Application Scientist, Tree Star Inc. Oregon, USA FLOWJO CYTOMETRY DATA ANALYSIS SOFTWARE

Size: px
Start display at page:

Download "Flow Data Analysis. Qianjun Zhang Application Scientist, Tree Star Inc. Oregon, USA FLOWJO CYTOMETRY DATA ANALYSIS SOFTWARE"

Transcription

1 Flow Data Analysis Qianjun Zhang Application Scientist, Tree Star Inc. Oregon, USA

2 Flow Data Analysis From Cells to Data - data measurement and standard Data display and gating - Data Display options - Gating strategy - Gating controls Statistics

3 From Cells to Data

4 From Cells to Data Informations collected Light Scatter parameters - Forward Scatter: proportional to cell size - Side Scatter: proportional to cell granularity or cell internal complexity Fluorescence parameters Time parameters

5 Flow Cytometry Standard FCS All those information about the cells or particles will be collected and write into a list mode file. The principal goal of the Standard is to provide a clearly defined and uniform file format allowing files created by one type of acquisition instrument to be analyzed by another type on another computer

6 The History of FCS Format Version YEAR FORMAT SOURCE NOTES 1984 FCS 1.0 Robert F. Murphy et al., Cytometry 5: First data format 1990 FCS 2.0 ISAC, Cytometry 11: Data File Standard committee of ISAC revised the FCS1.0 and adopted the format 1997 FCS 3.0 L. C. Seamer et al., Cytometry 28: Handle large files (>100MB), support unicode text as keyword for the need of internalization.

7 The FCS Standard Requires that Each Data Set in a File Contains Three Segments: HEADER, TEXT and DATA, with an Optional ANALYSIS Segment Contain all of the measurements(fsc-h, FSC-A, SSC-H, SSC- A,FL1-H ) for each individual cell processed in a given sample

8 Scatter Profile of Whole Blood Granularity Side Scatter! Smallest and least granular population 0! 200! 400! 600! 800! 1000! 0! 200! 400! 600! 800! 1000! Forward Scatter! Size Largest and most granular population Granulocytes Monocytes Lymphocytes Slide credit to Dr. Holden Maecker Stanford University

9 Fluorescence Data Display Histogram Bivariate plots Multidimensional plots

10 &./01!-"!"" - "!"#$%!"&'((%) * +. * + - * +, * + * Histograms - Histograms display the distributions of the events for one parameter -The X--fluorescence intensity -The Y--number of cells per channel " * + +! " "! "!! " #! " $! " % &'()*+,& * + + * + * * +, * + - * +. Histogram overlays Control $-./0$ ( ), ( ) + ( ) * ( ) ( ) ( ) ) ( ) ( ( ) * ( ) + ( ), ( ) )!"#$%&'! ( ) ) ( ) ( ( ) * ( ) + ( ),! " "! "!! " #! " $! " %

11 Bivariate Displays-Dot Plots Bivariate plots display data with any two parameters, Scatter parameter or Fluorescence parameter Adjunct Histogram!"#$%!&'(($) *+,-./&+($ !"#$! * !"#$%$&'(() *+,#-!".$%$!'(() #/,0-!"#$! * 1 2 1!"#$%$&'(() *+,#-!".$%$!'(() #/, Forward Scatter * 1 2 3!".$ Each dot corresponds one or more cell events - Pro: show rare events very well - Cons: Saturate in areas of high cell density, no indication of the relative density of the events * 1 2 3!".$67 A perfect way to show both histogram and the dot plot. Showing the histogram of each parameter along with traditional dot plots, provide more info to your data

12 Bivariate Displays-More Options Density Plot Contour plot Pseudocolor Plot Pseudocolor Plot(smooth) Dot Plot Zebra Plot

13 Bivariate Displays - Show Outliers Density Plot Contour plot Pseudocolor Plot Pseudocolor Plot(smooth) Dot Plot Zebra Plot

14 3D

15 3D movie i!ustration was generated by FlowJo V7.6 Song by The Black Keys Things Ain t like They Used to Be

16 Flow Data Analysis From Cells to Data - data measurement and standard Data display and gating - Data Display options - Gating strategy - Gating controls Statistics

17 Gating: Define Population(s) of Interest(POI) Gating basic - Gate on population of interest and gate out population not of interest - Gate out debris, dead cells,doublets/cell aggregates, Focus on POI - Is both objective and subjective Gating tools - Hierarchical gating - Show ancestry& Backgating

18 Debris Debris are particles smaller than cells, they can easily distinguished by size %"!# %"!# %!!# %!!# ''()* $"!# $!!#!"#$%&'()*+,-./0 ''()* $"!# $!!# "!# "!#!!! "!# $!!# $"!# %!!# %"!# &'()*! "!# $!!# $"!# %!!# %"!# &'()*

19 Doublets Discrimination What are doublets and why are they harmful? - Doublets are two cells stick together - Doublets can lead to higher background and false positive and especially harmful for cell cycle analysis. Single Cell Doublets Gate on Area Vs Height 1.-/ 2! / '!"#$%' ()'*+,-.'!"#$%&'(&)*+,-& 2! / 0--/!"#$%&'( )*+*,.-/ -!"#$%&!' Flight of time!"#$%./!& -.-/ 0--/ 0.-/ 1--/ 1.-/ 2!346

20 Does It Matter Which Parameter to Use in Doublets *! !"#$%&'()*!+),-. /0123 *!+9: !"#$%&'()*!+),-: /0173 Rule to live by Choose what works best for you *!+9, !! !"#$%&'()!!+),-. /21;3!!+9: !"#$%&'()!!+),-: /81; !!+9,

21 Viability Check Dead cells are sticky and can bind to anything, including your fluorochrome conjugated Ab, generating background and false positive. DNA dyes: penetrate compromised membranes DAPI Hoechst Hoechst AAD PI Other types Annexin V: ca2+dependent phospholipid binding protein, apoptosis cells Invitrogen's violet-excited live/ dead fixable viability dyes:binding to cellular amine

22 Dead Cells Exclusion /2-= /--=!"#$%&$''( )*+*, >>37<.2-=.--= 2-= / !"#$89$:;7<%)<<9

23 Gating Strategy Gate out Debris Gate out doublets ''()* %"!# %!!# $"!# $!!#!"#$%&'()*+,-./0 ''()* %"!# %!!# $"!# $!!# Debris(NOT) 2! / 1--/ 0.-/ 0--/ Singlets!"#$%&'( )*+*, "!# "!#.-/!! -! "!# $!!# $"!# %!!# %"!# &'()*! "!# $!!# $"!# %!!# %"!# &'()* -.-/ 0--/ 0.-/ 1--/ 1.-/ 2!346 FlowJo hierarchical gating tree %"!# %!!# Plot on FSC&SSC POI /2-= /--=!"#$%&$''( )*+*, Gate out dead Live cells randparent Parent Child ''()* $"!# $!!# >>37<.2-=.--= "!# 2-=!! "!# $!!# $"!# %!!# %"!# &'()* / !"#$89$:;7<%)<<9

24 Gating Strategy - Continued %"!# %!!# Monocytes POI ()"% "! & "! % "! $ "! #! ''()* $"!# $!!#! "! # "! $ "! % "! & '()$# "!#! #&!' #!!'! "!# $!!# $"!# %!!# %"!# &'()* (()*+ "&!' ),$* "$6"7 ),$-./ %7 "!!' Lymphocytes &!'!! "! # "! $ "! % "! &.),$

25 Backgating as a Gate Validation Tool Loosen Gate Show Ancestry Backgating Tighter Gate Backgating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

26 Summary I - Gating Clean up the cells by gating out debris, doublets, dead cells before proceeding to POI Use hierarchical gating and show ancestry to easily track your gating trees Use backgating tool to validate your gates

27 Yet, to Properly Analyze Data, We Need Controls! Compensation controls - To correct spectra spillover FMO controls : Fluorescence minus one - To define positive population Biological controls - Experimental controls(untreated vs treated) - Unstained controls - Isotype controls(for non-specific binding) - Viability controls

28 Compensation Controls-To Correct Spectra Spillover FITC PE Uncompensated Compensated Wavelength True PE =total FL2 -FITC spill over FITC median fluorescence PE median fluorescence Negative Positive Negative Positive Uncompensated 125 3, ,650 Compensated 125 3, , % Spillover = X 100 3, %spillover remains the same for the same fluorochrome

29 Compensation Rule#1 Compensation is about fluorochrome, not about particular antibody or cell type To set up compensation control Don t have to use the same Abs used in the experiment with the exception of Tandem Dyes Don t have to use the same cell type used in the experiment, alternatives are other cell types or antibody capture beads antibody capture beads are great alternatives due to its brightness and sharp peaks(small CV). there are caveats: beads are not available to every antibody type and beads staining has to be as bright or even brighter than you sample staining.

30 Myths About Compensation Save the compensation setting and use it next time - Almost never, there are exceptions, but you have to know what you are doing Mix positive and negative population of different cell type in one comp control tube - The negative and positive population must have the same autofluorescence, thus the same type - Don t mix comp beads and cells to compensate individual parameter - OK to compensate some parameters with beads and others with cells Set compensation by eye - Never!

31 Ways to Compensate Instrument compensation Out: old school Subjective: Inaccurate manual adjustment Complicated Acquisition Permanent: the matrix wrote into the FCS file and not removable with FCS 2.0 Software compensation In: new generation Objective: Accurate calculate mathematically Simplifies Acquisition Non-permanent: create and modify matrix with ease

32 Biexponential Transformation - to Better Visualize Data After Compensation Y=X Y=log(x) y=arcsinh(x) - Transformation is a bi-exponential display tool by introducing linear scales into your axes to better visualize your data - It does not change your data! Herzenberg et. al. Nature Immunology 2006

33 Use Fluorescence Minus One (FMO) Controls.45*! 67! *2867! *2967!!"!!"! &!!"! %!!"! $!!"! #!!"!!!"! "! Isotype!"! "!!"!!!"! #!!"! $!!"! %! #$%&! - to Identify Positives :! :! :! :! The cells are stained with all the reagents except onefluorescence minus one!"#$%&"'()*+"$,+-!./0)*+"$,+-!.1--2)3$%&"'(! *;<! *;<! :! *;>! *;=! *;=! *;>8?0! *;>8?0!!"#$%&'()#*+," FMO!"#$%&'()*!"! "!!"!!!"! #!!"! $!!"! %!!"! "!!"!!!"! #!!"! $!!"! %! Slide credited to Dr. Mario Roederer

34 FMO Compensated data exhibits spread Bright single positives may change threshold levels between dim and background in other dimensions Isotype is not useful in many cases Unstained cells or complete isotype control stains are improper controls for determining positive vs. negative expression in multi-color experiments. FMO should be used when the antigen expression is low or dim The Best control!! Graph credit to Dr. Cynthia Guidos Hospital for Sick Children Research Institute Toronto

35 Summary II - Controls Always run proper compensation controls and use software compensation instead of hardware Get used to the idea of Biexpoenential display to better visualize and present your data FMO is the best control to distinguish positive from the negative

36 Statistics - Mean, Median & Mode Mean: the sum of the linear values divided by the total number of events. - Require normal distribution - In most case, mean refer to linear armetric mean, if you work on log scale use Geometry mean Median: the point in the distribution where 50% of the population lies to either side - Do not have assumption about the data distribution, it can be in any shape, the same applies to mode - Is less affected by outliers and probably is a better measurement for most flow cytometry data Mode: the value that is of most frequently found in the data MEAN = MEDIAN = MODE MEAN = MEDIAN = MODE > > MEAN MEDIAN MODE MEAN < MEDIAN < MODE

37 SD and CV SD=Standard Deviation CV=Coefficient of Variance Both measure the width of the peak and require a normal distribution - SD has the same units of the mean, is a absolute value - Low SD means the data is tightly distributed around the mean. - Normal distribution, 68% is within 1SD of the mean. with 99.7% of the data within 3 SD of the mean - CV=SD/mean - A relative number, best for comparing between samples MEAN

38 rsd and rcv rsd=robust standard divination rcv=robust coefficient of variance Do not require a normal distribution rsd is based upon the deviation of individual data points to the median of the population rcv=rsd/median Robust statistics is a method to produce estimates not affected by small departures from the assumed model The data is less affected by outliers Is more appropriate for most flow cytometry data MEDIAN

39 MFI=Mean Fluorescence Intensity? MFI=Median Fluorescence Intensity? There is no standard definition for MFI, it must be defined within context From what we learn so far, median fluorescence intensity can be a more appropriate measurement to avoid outliers to skew your data But again it depends on your data

40 Take Home Messages Flow data is prettier than you think! Backgating as a validating tool to check your gates Always use proper gating controls (eg,fmo) and biological controls(eg, viability controls) Never underestimate the importance of compensation Use Median! Credit was given if a slide or part of the slide was borrowed or modified from other people s work. Flow Cyte training materials and Google search were utilized during the preparation of this talk

41 Online Resources Purdue University Cytometry Laboratories Purdue University Cytometry Laboratories Archive Invitrogen s Fluorescence Spectra Viewer BD s Fluorescence Spectra Viewer spectrumviewer/index.jsp The University of Chicago Flow Cytometry Facility Blog

42 FlowJo Session

Fluorescence Compensation. Jennifer Wilshire, PhD [email protected]

Fluorescence Compensation. Jennifer Wilshire, PhD jennifer@flowjo.com Fluorescence Compensation Jennifer Wilshire, PhD [email protected] Outline 1. Compensation Basics 2. Practical Applications -selecting comp controls (cells, stains?) 3. Multicolor Issues -spreading due

More information

Three Rules for Compensation Controls

Three Rules for Compensation Controls From FlowJo s Daily Dongle Three Rules for Compensation Controls First and foremost, there must be a single-stained control for every parameter in the experiment! In addition, there are three rules for

More information

COMPENSATION MIT Flow Cytometry Core Facility

COMPENSATION MIT Flow Cytometry Core Facility COMPENSATION MIT Flow Cytometry Core Facility Why do we need compensation? 1) Because the long emission spectrum tail of dyes causes overlap like with the fluorophores FITC and PE. 2) For sensitivity reasons,

More information

APPLICATION INFORMATION

APPLICATION INFORMATION DRAFT: Rev. D A-2045A APPLICATION INFORMATION Flow Cytometry 3-COLOR COMPENSATION Raquel Cabana,* Mark Cheetham, Jay Enten, Yong Song, Michael Thomas,* and Brendan S. Yee Beckman Coulter, Inc., Miami FL

More information

Technical Bulletin. Threshold and Analysis of Small Particles on the BD Accuri C6 Flow Cytometer

Technical Bulletin. Threshold and Analysis of Small Particles on the BD Accuri C6 Flow Cytometer Threshold and Analysis of Small Particles on the BD Accuri C6 Flow Cytometer Contents 2 Thresholds 2 Setting the Threshold When analyzing small particles, defined as particles smaller than 3.0 µm, on the

More information

FlowJo Basic Tutorial

FlowJo Basic Tutorial FlowJo Basic Tutorial FlowJo is software for the analysis of flow cytometry data. This tutorial will quickly introduce you to FlowJo using an example experiment, where a FITC anti-cd8 reagent is titrated

More information

Immunophenotyping peripheral blood cells

Immunophenotyping peripheral blood cells IMMUNOPHENOTYPING Attune Accoustic Focusing Cytometer Immunophenotyping peripheral blood cells A no-lyse, no-wash, no cell loss method for immunophenotyping nucleated peripheral blood cells using the Attune

More information

Immunophenotyping Flow Cytometry Tutorial. Contents. Experimental Requirements...1. Data Storage...2. Voltage Adjustments...3. Compensation...

Immunophenotyping Flow Cytometry Tutorial. Contents. Experimental Requirements...1. Data Storage...2. Voltage Adjustments...3. Compensation... Immunophenotyping Flow Cytometry Tutorial Contents Experimental Requirements...1 Data Storage...2 Voltage Adjustments...3 Compensation...5 Experimental Requirements For immunophenotyping with FITC and

More information

Cell Cycle Tutorial. Contents

Cell Cycle Tutorial. Contents Cell Cycle Tutorial Contents Experimental Requirements...2 DNA Dyes...2 Protocols...3 PI Parameter & Analysis Setup...4 PI Voltage Adjustments...6 7-AAD Parameter Setup...6 To-Pro3 Parameter Setup...6

More information

Using the BD TM Cytometer Setup and Tracking (CS&T) System for Instrument Characterization and Performance Tracking

Using the BD TM Cytometer Setup and Tracking (CS&T) System for Instrument Characterization and Performance Tracking Using the BD TM Cytometer Setup and Tracking (CS&T) System for Instrument Characterization and Performance Tracking Mark KuKuruga Senior Technical Applications Specialist BD Biosciences 23-14462-00 Outline

More information

Multicolor Flow Cytometry: Setup and Optimization on the BD Accuri C6 Flow Cytometer

Multicolor Flow Cytometry: Setup and Optimization on the BD Accuri C6 Flow Cytometer Multicolor Flow Cytometry: Setup and Optimization on the BD Accuri C6 Flow Cytometer Presented by Clare Rogers, MS Senior Marketing Applications Specialist BD Biosciences 23-13660-00 Webinar Overview Multicolor

More information

Introduction to flow cytometry

Introduction to flow cytometry Introduction to flow cytometry Flow cytometry is a popular laser-based technology. Discover more with our introduction to flow cytometry. Flow cytometry is now a widely used method for analyzing the expression

More information

Compensation Controls Data Visualization Panel Development Gating Quantum Dots

Compensation Controls Data Visualization Panel Development Gating Quantum Dots Compensation Controls Data Visualization Panel Development Gating Quantum Dots FITC Single Stain Control FITC PE Argon Laser FL1 FL2 450 500 550 600 FITC Compensation Control Unwanted signal detected in

More information

Instructions for Use. CyAn ADP. High-speed Analyzer. Summit 4.3. 0000050G June 2008. Beckman Coulter, Inc. 4300 N. Harbor Blvd. Fullerton, CA 92835

Instructions for Use. CyAn ADP. High-speed Analyzer. Summit 4.3. 0000050G June 2008. Beckman Coulter, Inc. 4300 N. Harbor Blvd. Fullerton, CA 92835 Instructions for Use CyAn ADP High-speed Analyzer Summit 4.3 0000050G June 2008 Beckman Coulter, Inc. 4300 N. Harbor Blvd. Fullerton, CA 92835 Overview Summit software is a Windows based application that

More information

Introduction to Flow Cytometry

Introduction to Flow Cytometry Introduction to Flow Cytometry presented by: Flow Cytometry y Core Facility Biomedical Instrumentation Center Uniformed Services University Topics Covered in this Lecture What is flow cytometry? Flow cytometer

More information

CELL CYCLE BASICS. G0/1 = 1X S Phase G2/M = 2X DYE FLUORESCENCE

CELL CYCLE BASICS. G0/1 = 1X S Phase G2/M = 2X DYE FLUORESCENCE CELL CYCLE BASICS Analysis of a population of cells replication state can be achieved by fluorescence labeling of the nuclei of cells in suspension and then analyzing the fluorescence properties of each

More information

Selected Topics in Electrical Engineering: Flow Cytometry Data Analysis

Selected Topics in Electrical Engineering: Flow Cytometry Data Analysis Selected Topics in Electrical Engineering: Flow Cytometry Data Analysis Bilge Karaçalı, PhD Department of Electrical and Electronics Engineering Izmir Institute of Technology Outline Compensation and gating

More information

CyAn : 11 Parameter Desktop Flow Cytometer

CyAn : 11 Parameter Desktop Flow Cytometer CyAn : 11 Parameter Desktop Flow Cytometer Cyan ADP 3 excitation lines 488nm, 635nm, and UV or violet 11 simultaneous parameters FSC, SSC, and 7-9 colors with simultaneous width, peak, area, and log on

More information

BD FACSDiva 4.1 - TUTORIAL TSRI FLOW CYTOMETRY CORE FACILITY

BD FACSDiva 4.1 - TUTORIAL TSRI FLOW CYTOMETRY CORE FACILITY BD FACSDiva 4.1 - TUTORIAL TSRI FLOW CYTOMETRY CORE FACILITY IMPORTANT NOTES BEFORE READING THIS TUTORIAL This is a very expensive piece of equipment so PLEASE treat it with respect! After you are done

More information

Notes on titering antibodies

Notes on titering antibodies Home Events This Week Bulletin Boards Lab Personnel Lab Policies Protocols MolBio Tetramers Proteins Flow Cytometry Immunoassays Instruments Computers Lab Publications Scientiific Literature Science on

More information

How To Read Flow Cytometry Data

How To Read Flow Cytometry Data 26 Nature Publishing Group http://www.nature.com/natureimmunology Interpreting flow cytometry data: a guide for the perplexed Leonore A Herzenberg, James Tung, Wayne A Moore, Leonard A Herzenberg & David

More information

Katharina Lückerath (AG Dr. Martin Zörnig) adapted from Dr. Jörg Hildmann BD Biosciences,Customer Service

Katharina Lückerath (AG Dr. Martin Zörnig) adapted from Dr. Jörg Hildmann BD Biosciences,Customer Service Introduction into Flow Cytometry Katharina Lückerath (AG Dr. Martin Zörnig) adapted from Dr. Jörg Hildmann BD Biosciences,Customer Service How does a FACS look like? FACSCalibur FACScan What is Flow Cytometry?

More information

Application Information Bulletin: Set-Up of the CytoFLEX Set-Up of the CytoFLEX* for Extracellular Vesicle Measurement

Application Information Bulletin: Set-Up of the CytoFLEX Set-Up of the CytoFLEX* for Extracellular Vesicle Measurement Application Information Bulletin: Set-Up of the CytoFLEX Set-Up of the CytoFLEX* for Extracellular Vesicle Measurement Andreas Spittler, MD, Associate Professor for Pathophysiology, Medical University

More information

FACSCanto RUO Special Order QUICK REFERENCE GUIDE

FACSCanto RUO Special Order QUICK REFERENCE GUIDE FACSCanto RUO Special Order QUICK REFERENCE GUIDE INSTRUMENT: 1. The computer is left on at all times. Note: If not Username: Administrator Password: BDIS 2. Unlock the screen with your PPMS account (UTSW

More information

Multicolor Bead Flow Cytometry Standardization Heba Degheidy MD, PhD, QCYM DB/OSEL/CDRH/FDA Manager of MCM Flow Cytometry Facility

Multicolor Bead Flow Cytometry Standardization Heba Degheidy MD, PhD, QCYM DB/OSEL/CDRH/FDA Manager of MCM Flow Cytometry Facility Multicolor Bead Flow Cytometry Standardization Heba Degheidy MD, PhD, QCYM DB/OSEL/CDRH/FDA Manager of MCM Flow Cytometry Facility The mention of commercial products, their sources, or their use in connection

More information

1. Instrument Layout pg 2. 2. Summit Overview pg 3. 3. Data Storage and Data Files pgs 6-7. 4. Saving Data pg 7. 5. Start Up pg 8

1. Instrument Layout pg 2. 2. Summit Overview pg 3. 3. Data Storage and Data Files pgs 6-7. 4. Saving Data pg 7. 5. Start Up pg 8 Table of Contents 1. Instrument Layout pg 2 2. Summit Overview pg 3 3. Data Storage and Data Files pgs 6-7 4. Saving Data pg 7 5. Start Up pg 8 6. Choosing and Naming Parameters pg 9 7. Creating Histograms

More information

Compensation Basics - Bagwell. Compensation Basics. C. Bruce Bagwell MD, Ph.D. Verity Software House, Inc.

Compensation Basics - Bagwell. Compensation Basics. C. Bruce Bagwell MD, Ph.D. Verity Software House, Inc. Compensation Basics C. Bruce Bagwell MD, Ph.D. Verity Software House, Inc. 2003 1 Intrinsic or Autofluorescence p2 ac 1,2 c 1 ac 1,1 p1 In order to describe how the general process of signal cross-over

More information

Compensation in Flow Cytometry

Compensation in Flow Cytometry Compensation in UNIT.4 The term compensation, as it applies to flow cytometric analysis, refers to the process of correcting for fluorescence spillover, i.e., removing the signal of any given fluorochrome

More information

BD FACSComp Software Tutorial

BD FACSComp Software Tutorial BD FACSComp Software Tutorial This tutorial guides you through a BD FACSComp software lyse/no-wash assay setup run. If you are already familiar with previous versions of BD FACSComp software on Mac OS

More information

Introduction to Flow Cytometry -- BD LSR II. What is Flow Cytometry? What Can a Flow Cytometer Tell Us About a Cell? Particle Size

Introduction to Flow Cytometry -- BD LSR II. What is Flow Cytometry? What Can a Flow Cytometer Tell Us About a Cell? Particle Size Introduction to Flow Cytometry -- BD LSR II Daisy Kuo 郭 正 佼 Assistant Product Manager BD Biosciences [email protected] What is Flow Cytometry? Flow = Fluid Cyto = Cell Metry = Measurement A variety of measurements

More information

Using BD FACSDiva CST To. Evaluate Cytometer Performance, Create Custom Assay Settings. and

Using BD FACSDiva CST To. Evaluate Cytometer Performance, Create Custom Assay Settings. and Using BD FACSDiva CST To Evaluate Cytometer Performance, Create Custom Assay Settings and Implement Cross-Instrument and Cross-Site Standardization of Assays PART 2 Alan M. Stall Director, Advanced Cytometry

More information

Technical Bulletin. Standardizing Application Setup Across Multiple Flow Cytometers Using BD FACSDiva Version 6 Software. Abstract

Technical Bulletin. Standardizing Application Setup Across Multiple Flow Cytometers Using BD FACSDiva Version 6 Software. Abstract arch 212 Standardizing Application Setup Across ultiple Flow Cytometers Using BD FACSDiva Version 6 Ellen einelt, ervi Reunanen, ark Edinger, aria Jaimes, Alan Stall, Dennis Sasaki, Joe Trotter Contents

More information

Application Note. Selecting Reagents for Multicolor Flow Cytometry. Holden Maecker and Joe Trotter BD Biosciences, San Jose

Application Note. Selecting Reagents for Multicolor Flow Cytometry. Holden Maecker and Joe Trotter BD Biosciences, San Jose Selecting Reagents for Multicolor Flow Cytometry Holden Maecker and Joe Trotter BD Biosciences, San Jose Contents 1 The basics: Know your instrument 2 Fluorochromes: Go for the bright 3 Colors and specificities:

More information

Instrument Characterization and Performance Tracking for Digital Flow Cytometers

Instrument Characterization and Performance Tracking for Digital Flow Cytometers Instrument Characterization and Performance Tracking for Digital Flow Cytometers BD Biosciences Cytometer Set-up & Tracking (CS&T) System For Research Use Only. Not for use in diagnostic or therapeutic

More information

These particles have something in common

These particles have something in common These particles have something in common Blood cells Chromosomes Algae Protozoa Certain parameters of these particles can be measured with a flow cytometer Which parameters can be measured? the relative

More information

Using CyTOF Data with FlowJo Version 10.0.7. Revised 2/3/14

Using CyTOF Data with FlowJo Version 10.0.7. Revised 2/3/14 Using CyTOF Data with FlowJo Version 10.0.7 Revised 2/3/14 Table of Contents 1. Background 2. Scaling and Display Preferences 2.1 Cytometer Based Preferences 2.2 Useful Display Preferences 3. Scale and

More information

123count ebeads Catalog Number: 01-1234 Also known as: Absolute cell count beads GPR: General Purpose Reagents. For Laboratory Use.

123count ebeads Catalog Number: 01-1234 Also known as: Absolute cell count beads GPR: General Purpose Reagents. For Laboratory Use. Page 1 of 1 Catalog Number: 01-1234 Also known as: Absolute cell count beads GPR: General Purpose Reagents. For Laboratory Use. Normal human peripheral blood was stained with Anti- Human CD45 PE (cat.

More information

No-wash, no-lyse detection of leukocytes in human whole blood on the Attune NxT Flow Cytometer

No-wash, no-lyse detection of leukocytes in human whole blood on the Attune NxT Flow Cytometer APPLICATION NOTE Attune NxT Flow Cytometer No-wash, no-lyse detection of leukocytes in human whole blood on the Attune NxT Flow Cytometer Introduction Standard methods for isolating and detecting leukocytes

More information

Flow Cytometry Workshop:

Flow Cytometry Workshop: Flow Cytometry Workshop: Section III: DNA Content Analysis Beckman Coulter Taiwan Branch 技 術 支 援 經 理 楊 人 泰 DNA Content Analysis-common sense DNA content analysis is one of the oldest Flow applications.

More information

Technical Bulletin. An Introduction to Compensation for Multicolor Assays on Digital Flow Cytometers

Technical Bulletin. An Introduction to Compensation for Multicolor Assays on Digital Flow Cytometers An Introduction to Compensation for Multicolor Assays on Digital Flow Cytometers BD Biosciences, San Jose, CA Contents 2 Introduction to compensation 5 Tips for setting up compensation 10 Tools for easy,

More information

UCHC Guide to CellQuest Pro. FACS Calibur instruments

UCHC Guide to CellQuest Pro. FACS Calibur instruments UCHC Guide to CellQuest Pro FACS Calibur instruments Startup: Turn on Cytometer using green switch on the side of the cytometer Cytometer Power Switch Within a minute of turning on the cytometer; turn

More information

Analyzer Experiment setup guide for LSRII and Canto s

Analyzer Experiment setup guide for LSRII and Canto s Analyzer Experiment setup guide for LSRII and Canto s 1. Check the instrument configuration on our website to determine the most appropriate cytometer for your experiment, https://depts.washington.edu/flowlab/instrumentation.html,

More information

Automated Quadratic Characterization of Flow Cytometer Instrument Sensitivity (flowqb Package: Introductory Processing Using Data NIH))

Automated Quadratic Characterization of Flow Cytometer Instrument Sensitivity (flowqb Package: Introductory Processing Using Data NIH)) Automated Quadratic Characterization of Flow Cytometer Instrument Sensitivity (flowqb Package: Introductory Processing Using Data NIH)) October 14, 2013 1 Licensing Under the Artistic License, you are

More information

Supplementary Material. Free-radical production after post-thaw incubation of ram spermatozoa is related to decreased in vivo fertility

Supplementary Material. Free-radical production after post-thaw incubation of ram spermatozoa is related to decreased in vivo fertility 10.1071/RD14043_AC CSIRO 2015 Supplementary Material: Reproduction, Fertility and Development, 2015, 27(8), 1187 1196. Supplementary Material Free-radical production after post-thaw incubation of ram spermatozoa

More information

Stepcount. Product Description: Closed transparent tubes with a metal screen, including a white matrix at the bottom. Cat. Reference: STP-25T

Stepcount. Product Description: Closed transparent tubes with a metal screen, including a white matrix at the bottom. Cat. Reference: STP-25T Product Description: Closed transparent tubes with a metal screen, including a white matrix at the bottom Cat. Reference: STP-25T Reagent provided:: 25 Stepcount tubes for 25 test INTENDED USE. Immunostep

More information

Below is a list of things you should be aware of before you schedule your sort.

Below is a list of things you should be aware of before you schedule your sort. Sorting at the Flow Cytometry Facility At the present time, the assistance of a trained cell sorter operator is needed for all sorting applications. As such, if you are planning a first time sort you will

More information

CELL CYCLE BASICS. G0/1 = 1X S Phase G2/M = 2X DYE FLUORESCENCE

CELL CYCLE BASICS. G0/1 = 1X S Phase G2/M = 2X DYE FLUORESCENCE CELL CYCLE BASICS Analysis of a population of cells replication state can be achieved by fluorescence labeling of the nuclei of cells in suspension and then analyzing the fluorescence properties of each

More information

Spherotech, Inc. 27845 Irma Lee Circle, Unit 101, Lake Forest, Illinois 60045 1

Spherotech, Inc. 27845 Irma Lee Circle, Unit 101, Lake Forest, Illinois 60045 1 78 Irma Lee Circle, Unit 0, Lake Forest, Illinois 00 SPHERO TM Technical Note STN- Rev B 008 DETERMINING PMT LINEARITY IN FLOW CYTOMETERS USING THE SPHERO TM PMT QUALITY CONTROL EXCEL TEMPLATE Introduction

More information

Introduction to Flow Cytometry

Introduction to Flow Cytometry Outline Introduction to Flow Cytometry Basic Concept of Flow Cytometry Introduction to Instrument Subsystems Daisy Kuo Assistant Product Manager E-mail: [email protected] BDBiosciences Application Examples

More information

Flow Cytometry. What is Flow Cytometry? What Can a Flow Cytometer Tell Us About a Cell? Particle Size. Flow = Fluid Cyto = Cell Metry = Measurement

Flow Cytometry. What is Flow Cytometry? What Can a Flow Cytometer Tell Us About a Cell? Particle Size. Flow = Fluid Cyto = Cell Metry = Measurement What is Flow Cytometry? Flow Cytometry Basic Principle and Applications BD Biosciences Daisy Kuo ([email protected]) Flow = Fluid Cyto = Cell Metry = Measurement A variety of measurements are made on cells,

More information

LSR II Users Guide Stanford Shared FACS Facility 06/10/13

LSR II Users Guide Stanford Shared FACS Facility 06/10/13 LSR II Users Guide Stanford Shared FACS Facility 06/10/13 A configuration sheet is located on the Website in the Instrument Overview area Do I need to run beads when I collect data using Diva Digital?

More information

--Verity Software House, ModFit for Proliferation http://www.vsh.com/ offers online tutorials

--Verity Software House, ModFit for Proliferation http://www.vsh.com/ offers online tutorials Customers may want to use another analysis software package with data collected on Attune. Reason for this include: they already have the SW and are confortable with using it, their institution may provide

More information

MEASURABLE PARAMETERS: Flow cytometers are capable of measuring a variety of cellular characteristics such as:

MEASURABLE PARAMETERS: Flow cytometers are capable of measuring a variety of cellular characteristics such as: INTRODUCTION Flow Cytometry involves the use of a beam of laser light projected through a liquid stream that contains cells, or other particles, which when struck by the focused light give out signals

More information

FlowSight. Flow cytometry with vision

FlowSight. Flow cytometry with vision FlowSight Flow cytometry with vision Flow cytometry with vision Introducing FlowSight Capable: Sensitive and flexible for every need Intuitive: Easy-to-use, with imagery for every cell Affordable: Designed

More information

use. 3,5 Apoptosis Viability Titration Assays

use. 3,5 Apoptosis Viability Titration Assays Introduction Monitoring cell viability can provide critical insights into the effectiveness of biological protocols and the stability of biological systems including: the efficacy of cell harvesting procedures,

More information

Standardization, Calibration and Quality Control

Standardization, Calibration and Quality Control Standardization, Calibration and Quality Control Ian Storie Flow cytometry has become an essential tool in the research and clinical diagnostic laboratory. The range of available flow-based diagnostic

More information

PROTOCOL. Immunostaining for Flow Cytometry. Background. Materials and equipment required.

PROTOCOL. Immunostaining for Flow Cytometry. Background. Materials and equipment required. PROTOCOL Immunostaining for Flow Cytometry 1850 Millrace Drive, Suite 3A Eugene, Oregon 97403 Rev.0 Background The combination of single cell analysis using flow cytometry and the specificity of antibody-based

More information

A Basic Guide. Institute of Medical Biology, University of Southern Denmark. Ungated Gate 1 (= R1) Gate 4 (=R4) Gate3 (=R3) Gate 2 (= R2) R3 R4

A Basic Guide. Institute of Medical Biology, University of Southern Denmark. Ungated Gate 1 (= R1) Gate 4 (=R4) Gate3 (=R3) Gate 2 (= R2) R3 R4 Flow Cytometry A Basic Guide R1 Ungated Gate 1 (= R1) R2 R3 R4 Gate 2 (= R2) Gate3 (=R3) Gate 4 (=R4) Graham Leslie, PhD Institute of Medical Biology, University of Southern Denmark Graham Leslie, PhD

More information

Application Note 10. Measurement of Cell Recovery. After Sorting with a Catcher-Tube-Based. Cell Sorter. Introduction

Application Note 10. Measurement of Cell Recovery. After Sorting with a Catcher-Tube-Based. Cell Sorter. Introduction Application Note 10 Measurement of Cell Recovery After Sorting with a Catcher-Tube-Based Cell Sorter Introduction In many experiments using sorted cells, it is important to be able to count the number

More information

Compensation: An Instrumental Perspective

Compensation: An Instrumental Perspective Compensation: An Instrumental Perspective Why Digital? Visualization Issues Boston User s Group September 10, 2003 Joe Trotter [email protected] Review: Instrument Sensitivity Measuring Sensitivity -

More information

Introduction into Flow Cytometry

Introduction into Flow Cytometry Introduction into Flow Cytometry Stephanie Gurka, Andreas Hutloff, Timo Lischke, Kroczek-Lab, Robert Koch Institute, Berlin Flow Cytometry - FCM FACS = Fluorescence Activated Cell Sorting (also used for

More information

Descriptive Statistics

Descriptive Statistics Y520 Robert S Michael Goal: Learn to calculate indicators and construct graphs that summarize and describe a large quantity of values. Using the textbook readings and other resources listed on the web

More information

Data Mining: Exploring Data. Lecture Notes for Chapter 3. Introduction to Data Mining

Data Mining: Exploring Data. Lecture Notes for Chapter 3. Introduction to Data Mining Data Mining: Exploring Data Lecture Notes for Chapter 3 Introduction to Data Mining by Tan, Steinbach, Kumar What is data exploration? A preliminary exploration of the data to better understand its characteristics.

More information

Too Many B Cells: Chronic Lymphocytic Leukemia and the Role of Flow Cytometry

Too Many B Cells: Chronic Lymphocytic Leukemia and the Role of Flow Cytometry Too Many B Cells: Chronic Lymphocytic Leukemia and the Role of Flow Cytometry by Debby R. Walser-Kuntz Biology Department Carleton College, Northfield, MN Taylor goes in to see her doctor, Dr. Chavez,

More information

Science is hard. Flow cytometry should be easy.

Science is hard. Flow cytometry should be easy. Science is hard. Flow cytometry should be easy. TABLE OF CONTENTS 1 INTRODUCTION TO BD ACCURI C6 SOFTWARE... 1 1.1 Starting BD Accuri C6 Software... 1 1.2 BD Accuri C6 Software Workspace... 2 1.3 Opening

More information

Exploratory data analysis (Chapter 2) Fall 2011

Exploratory data analysis (Chapter 2) Fall 2011 Exploratory data analysis (Chapter 2) Fall 2011 Data Examples Example 1: Survey Data 1 Data collected from a Stat 371 class in Fall 2005 2 They answered questions about their: gender, major, year in school,

More information

LIVE/DEAD Fixable Dead Cell Stain Kits

LIVE/DEAD Fixable Dead Cell Stain Kits USER GUIDE LIVE/DEAD Fixable Dead Cell Stain Kits Pub. No. MAN0002416 (MP34955) Rev. A.0 Table 1. Contents and storage Material Amount Storage Stability Individual Kits: Blue, violet, aqua, yellow-, green,

More information

STATS8: Introduction to Biostatistics. Data Exploration. Babak Shahbaba Department of Statistics, UCI

STATS8: Introduction to Biostatistics. Data Exploration. Babak Shahbaba Department of Statistics, UCI STATS8: Introduction to Biostatistics Data Exploration Babak Shahbaba Department of Statistics, UCI Introduction After clearly defining the scientific problem, selecting a set of representative members

More information

FLOW CYTOMETRY: PRINCIPLES AND APPLICATIONS. By: Douaa Moh. Sayed

FLOW CYTOMETRY: PRINCIPLES AND APPLICATIONS. By: Douaa Moh. Sayed FLOW CYTOMETRY: PRINCIPLES AND APPLICATIONS By: Douaa Moh. Sayed Definition Flow cytometry is a technique for counting, examining, and sorting microscopic particles suspended in a stream of fluid. It allows

More information

1) Write the following as an algebraic expression using x as the variable: Triple a number subtracted from the number

1) Write the following as an algebraic expression using x as the variable: Triple a number subtracted from the number 1) Write the following as an algebraic expression using x as the variable: Triple a number subtracted from the number A. 3(x - x) B. x 3 x C. 3x - x D. x - 3x 2) Write the following as an algebraic expression

More information

Uses of Flow Cytometry

Uses of Flow Cytometry Uses of Flow Cytometry 1. Multicolour analysis... 2 2. Cell Cycle and Proliferation... 3 a. Analysis of Cellular DNA Content... 4 b. Cell Proliferation Assays... 5 3. Immunology... 6 4. Apoptosis... 7

More information

Describing, Exploring, and Comparing Data

Describing, Exploring, and Comparing Data 24 Chapter 2. Describing, Exploring, and Comparing Data Chapter 2. Describing, Exploring, and Comparing Data There are many tools used in Statistics to visualize, summarize, and describe data. This chapter

More information

ab139418 Propidium Iodide Flow Cytometry Kit for Cell Cycle Analysis

ab139418 Propidium Iodide Flow Cytometry Kit for Cell Cycle Analysis ab139418 Propidium Iodide Flow Cytometry Kit for Cell Cycle Analysis Instructions for Use To determine cell cycle status in tissue culture cell lines by measuring DNA content using a flow cytometer. This

More information

ArC Amine Reactive Compensation Bead Kit

ArC Amine Reactive Compensation Bead Kit ArC Amine Reactive Compensation Bead Kit Catalog no. A1346 Table 1. Contents and storage information. Material Amount Composition Storage Stability ArC reactive beads (Component A) ArC negative beads (Component

More information

UCHC Guide to FACS DiVa. LSR II instruments

UCHC Guide to FACS DiVa. LSR II instruments UCHC Guide to FACS DiVa LSR II instruments Start Up: Turn on the instrument using the Green power button. Fluidics pump power, LSR II-B & C LSR II-B and LSRII-C-> Turn on the fluidics pump and ensure that

More information

Flow Cytometry for Everyone Else Susan McQuiston, J.D., MLS(ASCP), C.Cy.

Flow Cytometry for Everyone Else Susan McQuiston, J.D., MLS(ASCP), C.Cy. Flow Cytometry for Everyone Else Susan McQuiston, J.D., MLS(ASCP), C.Cy. At the end of this session, the participant will be able to: 1. Describe the components of a flow cytometer 2. Describe the gating

More information

BD CellQuest Pro Software Analysis Tutorial

BD CellQuest Pro Software Analysis Tutorial BD CellQuest Pro Analysis Tutorial This tutorial guides you through an analysis example using BD CellQuest Pro software. If you are already familiar with BD CellQuest Pro software on Mac OS 9, refer to

More information

Becton-Dickinson FACSCalibur Flow Cytometer Instructions

Becton-Dickinson FACSCalibur Flow Cytometer Instructions Start-up 1. Turn on flow cytometer by pushing green button on right side of instrument, toward the back. Give it 30 minutes to warm up before collecting data. 2. Turn on monitor. 3. Turn on computer. If

More information

How to operate the BD FACSCanto flow cytometer

How to operate the BD FACSCanto flow cytometer How to operate the BD FACSCanto flow cytometer Preface Dear colleague, the BD FACSCanto flow cytometer is use to operate, however, it is a delicate instrument for measuring fluorescence of single cells.

More information

Hoechst 33342 HSC Staining and Stem Cell Purification Protocol (see Goodell, M., et al. (1996) J Exp Med 183, 1797-806)

Hoechst 33342 HSC Staining and Stem Cell Purification Protocol (see Goodell, M., et al. (1996) J Exp Med 183, 1797-806) Hoechst 33342 HSC Staining and Stem Cell Purification Protocol (see Goodell, M., et al. (1996) J Exp Med 183, 1797-86) The Hoechst purification was established for murine hematopoietic stem cells (HSC)

More information

Exploratory Data Analysis

Exploratory Data Analysis Exploratory Data Analysis Johannes Schauer [email protected] Institute of Statistics Graz University of Technology Steyrergasse 17/IV, 8010 Graz www.statistics.tugraz.at February 12, 2008 Introduction

More information

NyONE - Cell imaging in a bird s eye view 4. NyONE...resolution matters! 8. Features & benefits 10. Fluorescence excitation channels 12

NyONE - Cell imaging in a bird s eye view 4. NyONE...resolution matters! 8. Features & benefits 10. Fluorescence excitation channels 12 Envisions confirmed Content NyONE - Cell imaging in a bird s eye view 4 From cells to numbers 6 NyONE...resolution matters! 8 Features & benefits 10 Fluorescence excitation channels 12 Technical specifications

More information

Chapter 6. Antigen-Antibody Properties 10/3/2012. Antigen-Antibody Interactions: Principles and Applications. Precipitin reactions

Chapter 6. Antigen-Antibody Properties 10/3/2012. Antigen-Antibody Interactions: Principles and Applications. Precipitin reactions Chapter 6 Antigen-Antibody Interactions: Principles and Applications Antigen-Antibody Properties You must remember antibody affinity (single) VS avidity (multiple) High affinity: bound tightly and longer!

More information

DELPHI 27 V 2016 CYTOMETRY STRATEGIES IN THE DIAGNOSIS OF HEMATOLOGICAL DISEASES

DELPHI 27 V 2016 CYTOMETRY STRATEGIES IN THE DIAGNOSIS OF HEMATOLOGICAL DISEASES DELPHI 27 V 2016 CYTOMETRY STRATEGIES IN THE DIAGNOSIS OF HEMATOLOGICAL DISEASES CLAUDIO ORTOLANI UNIVERSITY OF URBINO - ITALY SUN TZU (544 b.c. 496 b.c) SUN TZU (544 b.c. 496 b.c.) THE ART OF CYTOMETRY

More information

Flow Cytometry 101. Jodi Moore, PhD Jan 2012 Goldenson 113

Flow Cytometry 101. Jodi Moore, PhD Jan 2012 Goldenson 113 Flow Cytometry 101 Jodi Moore, PhD Jan 2012 Goldenson 113 Origins:? Dye Chemistry 1940-1980 s Electronics Microscopy Automated Clinical Cytology ID Apps Computers Cytometry vs. Flow Cytometry Microspectrophotometry

More information

Flow Cytometry. flow cytometer DNA apoptosis ph

Flow Cytometry. flow cytometer DNA apoptosis ph Flow Cytometry flow cytometer DNA apoptosis ph flow cytometry flow cytometer (a) (b) cell counting instrument (c) 1960 ink-jet technology 17 19 1940 1950 fluorescence microscopy fluorescent dye DNA polyclonal

More information

GETTING STARTED. 6. Click the New Specimen icon.

GETTING STARTED. 6. Click the New Specimen icon. BD FACSDiva Software Basic Experiment Guide Please note, this guide is not intended to take the place of in-person training but is to be used as a reference as needed after completing training with Unified

More information

Summary of Formulas and Concepts. Descriptive Statistics (Ch. 1-4)

Summary of Formulas and Concepts. Descriptive Statistics (Ch. 1-4) Summary of Formulas and Concepts Descriptive Statistics (Ch. 1-4) Definitions Population: The complete set of numerical information on a particular quantity in which an investigator is interested. We assume

More information

Boundary-breaking acoustic focusing cytometry

Boundary-breaking acoustic focusing cytometry Boundary-breaking acoustic focusing cytometry Introducing the Attune NxT Acoustic Focusing Cytometer a high-performance system that s flexible enough for any lab One of the main projects in my laboratory

More information

Descriptive statistics Statistical inference statistical inference, statistical induction and inferential statistics

Descriptive statistics Statistical inference statistical inference, statistical induction and inferential statistics Descriptive statistics is the discipline of quantitatively describing the main features of a collection of data. Descriptive statistics are distinguished from inferential statistics (or inductive statistics),

More information

BD LSR II and FACSDiVa Software. Dr. Jens Fleischer, Basel Dr. Norbert Leclere,, Berlin

BD LSR II and FACSDiVa Software. Dr. Jens Fleischer, Basel Dr. Norbert Leclere,, Berlin BD LSR II and FACSDiVa Software, Basel Dr. Norbert Leclere,, Berlin Overview Electronics Covers Fluidics Connectors Controlpanel Sample Port On/Off The Control Panel Ease of Use The basic procedures to

More information

CyFlow SL. Healthcare Immunology. Portable FCM System for 3-colour Immunophenotyping

CyFlow SL. Healthcare Immunology. Portable FCM System for 3-colour Immunophenotyping CyFlow SL Healthcare Immunology Portable FCM System for 3-colour Immunophenotyping 01 COMPANY Flow Cytometry made in Germany New sophisticated applications and increasing requirements for reliable results

More information

WHOLE BLOOD LYSING SOLUTION FOR FLOW CYTOMETRIC APPLICATIONS

WHOLE BLOOD LYSING SOLUTION FOR FLOW CYTOMETRIC APPLICATIONS FOR IN-VITRO DIAGNOSTIC USE INVITROGEN CAL-LYSE TM Lysing Solution WHOLE BLOOD LYSING SOLUTION FOR FLOW CYTOMETRIC APPLICATIONS CAL-LYSE TM CATALOG No. GAS-010 250 tests 25 ml CATALOG No. GAS-010S-100

More information

II. DISTRIBUTIONS distribution normal distribution. standard scores

II. DISTRIBUTIONS distribution normal distribution. standard scores Appendix D Basic Measurement And Statistics The following information was developed by Steven Rothke, PhD, Department of Psychology, Rehabilitation Institute of Chicago (RIC) and expanded by Mary F. Schmidt,

More information

The NIAID Flow Cytometry Advisory Committee; the Guidelines Subcommittee

The NIAID Flow Cytometry Advisory Committee; the Guidelines Subcommittee January, 1999 From: To: Subject: The NIAID Flow Cytometry Advisory Committee; the Guidelines Subcommittee NIAID DAIDS Flow Cytometry Laboratories Comparison study information for labs wishing to switch

More information

FACS Laboratory. BD LSRs Operator Training. Training Guide. http://london-research-institute.org.uk/technologies/facs

FACS Laboratory. BD LSRs Operator Training. Training Guide. http://london-research-institute.org.uk/technologies/facs FACS Laboratory [email protected] Training Guide http://london-research-institute.org.uk/technologies/facs BD LSRs Operator Training LRI FACS lab 1 Components 1.1 Basic parts overview.pg3-6 Overview

More information

COM CO P 5318 Da t Da a t Explora Explor t a ion and Analysis y Chapte Chapt r e 3

COM CO P 5318 Da t Da a t Explora Explor t a ion and Analysis y Chapte Chapt r e 3 COMP 5318 Data Exploration and Analysis Chapter 3 What is data exploration? A preliminary exploration of the data to better understand its characteristics. Key motivations of data exploration include Helping

More information

Lesson 4 Measures of Central Tendency

Lesson 4 Measures of Central Tendency Outline Measures of a distribution s shape -modality and skewness -the normal distribution Measures of central tendency -mean, median, and mode Skewness and Central Tendency Lesson 4 Measures of Central

More information

Cytell Cell Imaging System

Cytell Cell Imaging System Cytell Cell Imaging System Simplify your cell analysis and start changing tomorrow today www.gelifesciences.com/cytell The Cytell Cell Imaging System is an intuitive cell analysis instrument that streamlines

More information