Type: DILM9 10(24VDC) Article No.: 276705



Similar documents
Type: DILM50(230V50HZ,240V60HZ) Article No.:

Type: DILM32 10(24V50HZ) Article No.:

Type: DILM115(RAC240) Article No.: Sales text Contactor,55kW/400V,AC operated. Ordering information

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

Technicaldata General

Emergency stop As an emergency switching off/emergency stop device. Standards According to IEC/EN , VDE 0113 Part 1

Electronic overload relay EF65, EF96 and EF146

Electronic overload relay EF19 and EF45

Three-phase monitoring relay CM-PFE

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A V AC coil

NF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals

AF / AF09Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Catalog. Modular DIN rail components Installation contactors

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages

RM4TG20 three-phase network control relay RM4-T - range V

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start * see variants. Applications.

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.

Technical catalogue. Modular DIN rail components Installation contactors

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

Analog signal converters CC-E I/I Current / current isolators

Thermistor motor protection relays CM-MSS.22 and CM-MSS.23

Bimetallic Overload Relay Specifications

BETA Switching. Switching Devices. 5TT5 8 Insta contactors, AC technology. Overview

Molded Case Circuit Breaker Specifications Bulletin Number 140U-D

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

ABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories

Manual motor starter MS116

Three-phase monitoring relays CM-PSS CM-PSS.31 and CM-PSS.41

VEO. V4PF480Y/277VSYTK02 Art.Nr.: V4PF480Y/277VSYTK02P Art.Nr.: TECHNICAL DATA

pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2, /0.65/0.

48 SERIES Relay interface modules 10 A

Application Switchgear for industrial and commercial applications. U e V AC 230/ (per pole)

Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller

RM35UA13MW. range V. Main. Product or component type. Relay monitored parameters

PHOENIX CONTACT Features

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Thermistor motor protection

38 Series - Relay interface modules A

Uncompromising safety and comfort The next generation of miniature circuit breakers MCB S 200/S 200 M

Easy Multifunctional Safe

Relés e Contatores de Estado Sólido SIRIUS

R.C.C.B. s two-pole LEXIC

38 Series - Relay interface modules A

Safety technique. Emergency stop module BO 5988 safemaster

Pluggable interface relays CR-P Pcb relays

Control Devices Catalogue. Control Devices. Preferred and Standard Products

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...

Redundancy Module QUINT-DIODE/40

CQM1-SF200/CS1W-SF200

Thermal-Magnetic Circuit Breaker M1-..

Installation Contactors. Technical Catalogue. Type ESB. abb. ABB STOTZ-KONTAKT GmbH 1 2CDC C0201

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Mini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protection

Series 8146/5-V37 and Series 8150/5-V37

ABB i-bus KNX Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG R0011

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase

Actuator-Sensor-Interface

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)

49 Series - Relay interface modules A. Features

ZS6-S Screw Clamp Terminal Blocks Disconnect with blade

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1

Manual Motor Starter MS 116 up to 16 A Technical Data

ZS4-S-T Screw Clamp Terminal Blocks Disconnect with blade - with test socket

E-STOP relays, safety gate monitors

Mini Motor Contactor J7KNA Main contactor Accessories Approved Standards Standard Guide No (US,C) Ordering Information tage Model Number Legend gear

Single-phase ( V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable

EMR measuring and monitoring relays

38 SERIES. Relay interface modules A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.

Bulletin 150 SMC Flex Smart Motor Controller Specifications

Multifunctional three-phase monitoring relays CM-MPS CM-MPS.43

5SV Residual Current Protective Devices

ABB i-bus KNX Switch Actuator, x-fold, 16 A, MDRC SA/S x , 2CDG1101xxR0011

ZS4-SF1-T Screw Clamp Terminal Blocks For 5 x 20 and 5 x 25 fuses - with test socket

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

Micro Contactors. Micro Contactor Relays. Micro Contactors With Solder Pins. Coil voltages. Micro Reversing Contactor. Technical Data.

34 Series - Slim electromechanical PCB relays 6 A. Features SERIES 34.51

W DATA SHEET: RESIDUAL CURRENT CIRCUIT BREAKER A, SERIES BCF0 AND BCF6

Contact expansion modules

Electric Rotary Actuator - On/Off or programmable control actuator

Preset Counter signo 721

H/L = Power supply. FN = Nominal Frequency. RN = Rated value of output burden. UN = Nominal input voltage. IN = Nominal input current.

Plug and Socket Devices CES 63 A Series 8579

Contact expander modules

ZS25 Screw Clamp Terminal Blocks Feed-through

Technical Manual Functional Description for S800-RSU-H / S800W-RSU 2CCC413022M Schaffhausen 1 / 10

MasterINTERFACE 39 Series - Relay interface modules

SKR - industry relay

ELECTROMAGNETIC DISC BRAKES

LINETRAXX VMD460-NA. Network and system protection (NS protection) for monitoring the power feed-in of power generation systems

PSR The compact range Description

Safety automation solutions

Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx

Automatic Transfer Switch-Controller ATS-C by Eaton. Automatic Transfer Switch- Controller ATS-C 96 and C 144

RY2 miniature industrial relays

60 Series - General purpose relays 6-10 A. Features

Transcription:

Type: DILM9 10(24VDC) Article No.: 276705 Ordering information Rated operational current AC 3 400 V I e A 9 Max. rating for three phase motors, 50 60 Hz AC 3 230 V Max. rating for three phase motors, 50 60 Hz AC 3 400 V Max. rating for three phase motors, 50 60 Hz AC 3 690 V Max. rating for three phase motors, 50 60 Hz AC 4 230 V Max. rating for three phase motors, 50 60 Hz AC 4 400 V Max. rating for three phase motors, 50 60 Hz AC 4 690 V P kw 2.5 P kw 4 P kw 4.5 P kw 1.5 P kw 2.5 P kw 3.6 Conventional thermal current I th = I e AC 1 Open I th = I e A 20 For use with DILM32 XHI.. DILA XHI(V).. General Standards IEC/EN 60947, VDE 0660, UL, CSA Lifespan, mechanical AC operated Operations 10 6 10 DC operated Operations 10 6 10 Operating frequency, mechanical AC operated Operations/h 9000 DC operated Operations/h 9000 Climatic proofing Ambient temperature Damp heat, constant, to IEC 60068 2 78 Damp heat, cyclical, to IEC 60068 2 30 1

Open C 25/60 Enclosed C 25/40 Storage C 40/80 Mechanical shock resistance (IEC/EN 60068 2 27) Half sinusoidal shock, 20 ms Main contacts Make contact g 10 Auxiliary contacts Make contact g 7 Break contact g 5 Protection type Protection against direct contact when actuated from front (IEC 536) Weight IP20 AC operated kg 0,23 DC operated kg 0,28 Terminal capacity Main cable Solid mm 2 1 (0.75 4) 2 (0.75 2.5) Flexible with ferrule mm 2 1 (0.75 2.5) 2 (0.75 2,5) Anschlussschraube Hauptleiter M3.5 Tightening torque Nm 1.2 Terminal capacity Control circuit cables Solid mm 2 1 (0.75 4) 2 (0.75 2.5) Flexible with ferrule mm2 Anschlussschraube Hilfsleiter M3.5 Tightening torque Nm 1.2 Tool Main cable Pozidriv screwdriver Size 2 Standard screwdriver Control circuit cables Pozidriv screwdriver Size 2 Standard screwdriver Terminal capacity Main cable mm mm Finger and back of hand proof 1 (0.75 2.5) 2 (0.75 2.5) 0.8 5.5 1 6 0.8 5.5 1 6 Solid mm 2 0.75 2.5 flexible mm 2 0.75 2.5 flexible with ferrules mm 2 0.75 2.5 Terminal capacity Control circuit cables 2

Solid mm 2 0.75 2.5 Flexible mm 2 0.75 2.5 Flexible with ferrule mm 2 0.75 2.5 Tool Stripping length mm 10 Screwdriver blade width mm 3,5 Main conducting paths Rated impulse withstand voltage U imp V AC 8000 Overvoltage category/pollution degree Rated insulation voltage AC U i V AC 690 Rated operational voltage U e V AC 690 Safe isolation to VDE 0106 Part 101 and Part 101/A1 between coil and contacts V AC 400 between the contacts V AC 400 Making capacity (cos Õ to IEC/EN 60947) up to 690 V Breaking capacity III/3 A 112 220/230 V A 90 380/400 V A 90 500 V A 70 660/690 V A 50 Component lifespan AC 3/AC 4 Tripping characteristics Maximum operating frequency AC 1; 400 V I e Ops/h 800 AC 3; 400 V I e Ops/h 1000 AC 4; 400 V I e Ops/h 300 Short circuit rating Short circuit protection Maximum fuse Type 2 coordination 400 V gg/gl 500 V A 20 690 V gg/gl 690 V A 16 Type 1 coordination 400 V gg/gl 500 V A 35 690 V gg/gl 690 V A 20 AC AC 1 duty conv. therm. current 3 pole 50 60 Hz open at 40 C I th A 22 at 50 C I th A 21 at 55 C I th A 21 at 60 C I th A 20 3

Enclosed I th A 18 Conventional free air thermal current, 1 pole open I th A 50 Enclosed I th A 45 AC 3 duty Rated operational current AC 3 open, 50 60 Hz, 3 pole 220/230 V I e A 9 240 V I e A 9 380/400 V I e A 9 415 V I e A 9 440V I e A 9 500 V I e A 7 660/690 V I e A 5 Motor rating 220/230 V P kw 2,5 240V P kw 3 380/400 V P kw 4 415 V P kw 5,5 440 V P kw 5,5 500 V P kw 4,5 660/690 V P kw 4,5 AC 4 duty Rated operational current AC 4 open, 50 60 Hz, 3 pole 220/230 V I e A 6 240 V I e A 6 380/400 V I e A 6 415 V I e A 6 440 V I e A 6 500 V I e A 5 660/690 V I e A 4,5 Motor rating 220/230 V P kw 1,5 240 V P kw 1,6 380/400 V P kw 2,5 415 V P kw 2,8 440 V P kw 3 500 V P kw 2,8 660/690 V P kw 3,6 DC of three phase capacitors open DC 1 operation 60 V I e A 20 110 V I e A 20 220 V I e A 15 440 V I e A 1,3 4

DC 3 operation 60 V I e A 20 110 V I e A 20 220 V I e A 1,5 440 V I e A 0,2 DC 5 operation 60 V I e A 20 110 V I e A 20 220 V I e A 1,5 440 V I e A 0,2 Current heat loss (3 pole) Current heat loss at I th W 4,7 Current heat loss at I e to AC 3/400 V W 0,6 Impedance per pole m& 2,5 Magnet systems Voltage tolerance AC operated AC operated Pick up U c 0,8 1,1 Drop out voltage AC operated Drop out voltage AC operated Abfall U c 0,3 0,6 DC operated DC operated Pick up U c 0,8 1,1 DC operated DC operated Abfall U c 0,15 0,6 Power consumption of the coil in a cold state and 1.0 U c 50 Hz Pick up VA 24 50 Hz Pick up W 19 50 Hz Sealing VA 4 50 Hz Sealing W 1,2 60 Hz Pick up VA 29 60 Hz Pick up W 23 60 Hz Sealing 4,4 60 Hz Sealing VA 1,3 50/60 Hz Pick up VA 50/60 Hz Pick up W 50/60 Hz Sealing VA 50/60 Hz Sealing W DC operated Pick up W 3 DC operated Sealing W 3 28 26 22 21 4,6 3,9 1,4 1,2 Duty factor % DF 100 Switching times at 100 % U c (approximate values) Main contacts 5

AC operated Closing delay ms 20 Opening delay ms 15 DC operated Closing delay ms 35 Opening delay ms 15 Arcing time ms 10 Electromagnetic compatibility (EMC) Emitted interference to EN 60947 1 Interference immunity to EN 60947 1 Mounting position Mounting position, AC and DC operated Moeller GmbH, Hein Moeller Str. 7 11, D 53115 Bonn E Mail: catalog@moeller.net, Internet: www.moeller.net, http://catalog.moeller.net Copyright 2005 by Moeller GmbH. Subject to modifications. HPL C2005GB INT V3.0 6