Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592. * see variants. Applications.



Similar documents
Safety technique. Emergency stop module BO 5988 safemaster

E-STOP relays, safety gate monitors

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors

PNOZsigma - Base units

E-STOP relays, safety gate monitors

Contact expansion modules

Contact expander modules

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

E-STOP relays, safety gate monitors

Type: DILM115(RAC240) Article No.: Sales text Contactor,55kW/400V,AC operated. Ordering information

RM4TG20 three-phase network control relay RM4-T - range V

Electronic overload relay EF19 and EF45

Three-phase monitoring relay CM-PFE

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

Safety automation solutions

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

mecotron Safety relay ESTOP-2 For emergency stop monitoring

Electronic overload relay EF65, EF96 and EF146

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

48 SERIES Relay interface modules 10 A

38 Series - Relay interface modules A

Type: DILM50(230V50HZ,240V60HZ) Article No.:

VEO. V4PF480Y/277VSYTK02 Art.Nr.: V4PF480Y/277VSYTK02P Art.Nr.: TECHNICAL DATA

RM35UA13MW. range V. Main. Product or component type. Relay monitored parameters

Type: DILM32 10(24V50HZ) Article No.:

Quick Connect. quick - simple - efficient.

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.

Type: DILM9 10(24VDC) Article No.:

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2, /0.65/0.

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages

38 Series - Relay interface modules A

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

ABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories

Relés e Contatores de Estado Sólido SIRIUS

Thermistor motor protection

Analog signal converters CC-E I/I Current / current isolators

PHOENIX CONTACT Features

Safety Manual BT50(T) Safety relay / Expansion relay

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

38 SERIES. Relay interface modules A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.

Pluggable interface relays CR-P Pcb relays

Preventa Machine Safety Products

Preset Counter signo 721

Power Supplies 3. SDN-P DIN Rail Series

Thermistor motor protection relays CM-MSS.22 and CM-MSS.23

LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A V AC coil

Three-phase monitoring relays CM-PSS CM-PSS.31 and CM-PSS.41

Bimetallic Overload Relay Specifications

CONFIGURABLE SAFETY RELAYS

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1

49 Series - Relay interface modules A. Features

MONITORING RELAYS. w VOLTAGE MONITORING RELAY UR5U1011. w SCHRACK-INFO. w TECHNICAL DATA

Catalog. Modular DIN rail components Installation contactors

SMS 4 / SMS 5 safety mat Product information

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...

Technicaldata General

H/L = Power supply. FN = Nominal Frequency. RN = Rated value of output burden. UN = Nominal input voltage. IN = Nominal input current.

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

PNOZ s3. Safety relays. Operating Manual EN-10

Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller

Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument D

NX safety stand-alone

CONFIGURABLE SAFETY RELAYS

DEK-REL- 24/1/SEN. Extract from the online catalog. Order No.:

MasterINTERFACE 39 Series - Relay interface modules

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)

RY2 miniature industrial relays

Redundancy Module QUINT-DIODE/40

MasterINTERFACE 39 Series - Relay interface modules

3RT1015-1BB41 CONTACTOR, AC-3 3 KW/400 V,

Actuator-Sensor-Interface

Thermal-Magnetic Circuit Breaker M1-..

AC/DC Power Modules C B. TML Series, 20 & 40 Watt. Features. 20 Watt Models

G7SA. Ordering Information. Slim Plug-In Safety Relay. Slim Safety Relay for Machine Control. H Slim body only 13 x 24 x 50 mm

CQM1-SF200/CS1W-SF200

Example of use: Fuse for a solenoid valve. If the fuse is defective, no information is sent to the electronic component.

ABB i-bus KNX Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG R0011

PNOZ s5. Safety relays. Operating Manual EN-09

Control Devices Catalogue. Control Devices. Preferred and Standard Products

Digital input modules

AF / AF09Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals

Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in

34 Series - Slim electromechanical PCB relays 6 A. Features SERIES 34.51

Manual motor starter MS116

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Product and functional description

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

ABB i-bus KNX SA/S Switch Actuators Product Manual

PROTECT. Safety Relay Modules PROTECT-SRB s Catalogue Protect/04

Application Switchgear for industrial and commercial applications. U e V AC 230/ (per pole)

Transcription:

Safety Technique SAFEMASTER Emergency Stop Module BG 5924, IP 5924 Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592 BG 5924 IP 5924 Product Description The emergency stop modules BG 5924 and IP 5924 can be used to protect people and machines by interrupting a safety circuit in a safe way. Features According to - Performance Level (PL) e and category 4 to EN ISO 849-1 - SIL Claimed Level (SIL CL) 3 to IEC/EN 62061 - Safety Integrity Level (SIL) 3 to IEC/EN 61508 According to EN 50156-1 for furnaces Single channel or two-channel operation Output max. 4 NO contacts AC 0 V model with galvanic separation LED indicator for channel 1 / 2 and state of operation Short circuit detection between terminal and common BG 5924 with - Removable terminal strips - Wire connection also 2 x 1.5 mm 2 stranded ferruled (isolated), DIN 46 228-1/-2/-3/-4 or 2 x 2.5 mm 2 stranded ferruled DIN 46 228-1/-2/-3 BG 5924 width 22.5 mm width 70 mm Function Diagram Pushbutton On Approvals and Markings * Canada / USA Canada * Emergency stop (Off) * see variants Applications Protection of people and machines Emergency stop circuits on machines Indicators M7218 LED Phase LED / on, when supply connected on, when relay and energized Block Diagrams.02.04 (+)(-) 33 41 (+)(-) 33 43 overvoltage- and short circuit protection monitoring logic overvoltage- and short circuit protection monitoring logic 24V power / 24V power / M7111_a 34 42 M7112_a 34 44 BG 5924.48, BG 5924.48/207, IP 5924.48 BG 5924.02, BG 5924.02/110, BG 5924.02/207, BG 5924.04, BG 5924.04/100, BG 5924.04/207, IP 5924.02, IP 5924.04 All technical data in this list relate to the state at the moment of edition. We reserve the right for technical improvements and changes at any time. 1 08.03.16 en / 657

Circuit Diagrams 33 43 33 43 34 44 M7129 M70 34 44 M7386_a BG 5924.02, BG 5924.02/110 BG 5924.02/207 BG 5924.04, BG 5924.04/100 43 41 33 33 33 33 43 33 41 33 41 34 44 34 42 34 42 34 M71 14 24 34 M7385_a 14 24 34 M72 44 41 42 42 BG 5924.04/207 BG 5924.48 BG 5924.48/207 33 43 33 41 34 44 34 42 33 43 33 41 M7911 34 44 IP 5924.02 IP 5924.04 IP 5924.48 M7912 34 42 M79 Connection Terminals Terminal designation Signal designation (+) + / L (-) - / N, Inputs, 14,, 24, 33, 34, 43, 44 Forcibly guided NO contacts for release circuit 41, 42 Forcibly guided indicator output Indicators ATTENTION - AUTOMATIC START! According to IEC/EN 60 204-1 part 9.2.5.4.2 and 10.8.3 it is not allowed to restart automatically after emergency stop. Therefore the machine control has to disable the automatic start after emergency stop. 2 08.03.16 en / 657

Technical Data Input Nominal voltage U N BG 5924 DC 24 V (only for variant /110) AC/DC 24, 48 V AC 110, 115, 0 V AC/DC 24, 48 V AC 110, 0 V Nominal frequency 50 / 60 Hz Voltage range AC 0.8... 1.1 U N at 10 % residual ripple DC 0.9... 1.1 U N at 48 % residual ripple DC 0.8... 1.1 U N Nominal consumption AC/DC 24 V DC 1.2 W AC 2 VA AC 0 V 3.5 VA Control voltage on AC/DC 24 V typ. DC V AC 0 V max. 45 V short pulse Control current typ. DC 45 ma Recovery time 0.5 s Output Contacts BG 5924.02, IP 5924.02 BG 5924.04, IP 5924.04 BG 5924.48, IP 5924.48 2 NO contacts 4 NO contacts 3 NO, 1 NC contacts The NO contacts are safety contacts. ATTENTION! The NC contacts 41-42 can only be used for monitoring. Operate delay max. 100 ms Release delay max. 35 ms Contact type forcibly guided Thermal current I th max. 5 A (see limit curve) Nominal output voltage AC 250 V Switching capacity to AC 15 NO contact 3 A / AC 0 V IEC/EN 60 947-5-1 NC contact 2 A / AC 0 V IEC/EN 60 947-5-1 to DC NO contact 1 A / DC 24 V IEC/EN 60 947-5-1 NC contact 1 A / DC 24 V IEC/EN 60 947-5-1 to DC NO contact 4 A / 24 V at 0.1 Hz NC contact 4 A / 24 V at 0.1 Hz Electrical life to AC 15 at 2 A, AC 0 V 10 5 switching cycles IEC/EN 60 947-5-1 Permissible operating frequency 600 switching cycles / h Short circuit strength max. fuse rating 4 A gl IEC/EN 60 947-5-1 line circuit breaker C 8 A Mechanical life 10 x 10 6 switching cycles Technical Data Terminal designation EN 50 005 Wire connection BG 5924 1 x 4 mm 2 solid or 1 x 2.5 mm 2 stranded ferruled (isolated) or 2 x 1.5 mm 2 stranded ferruled (isolated) DIN 46 228-1/-2/-3/-4 or 2 x 2.5 mm 2 stranded ferruled DIN 46 228-1/-2/-3 2 x 2.5 mm 2 solid or 2 x 1.5 mm 2 stranded ferruled DIN 46 228-1/-2/-3/-4 Wire fixing Box terminal wih wire protection, removable terminal strips Fixing torque 0.8 Nm Mounting DIN rail IEC/EN 60 715 Weight BG 5924 210 g 206 g Dimensions Width x height x depth BG 5924 Safety Related Data 22.5 x 84 x 121 mm 70 x 90 x 59 mm Values according to EN ISO 849-1 Category 4 PL e MTTF d 180.3 a DC / DC avg 99,0 % d op 365 d/a (days/year) h op 24 h/d (hours/day) t Zyklus 3600 s/zyklus = 1 /h (hour) Values according to IEC/EN 62061 / IEC/EN 61508 SIL CL 3 IEC/EN 62061 SIL 3 IEC/EN 61508 HFT 1 DC / DC avg 99.0 % SFF 99.7 % PFH D 2,80E-10h -1 T 1 20 a (year) *) HFT = Hardware-Failure Tolerance nfo The values stated above are valid for the standard type. Safety data for other variants are available on request. The safety relevant data of the complete system has to be determined by the manufacturer of the system. General Data Operating mode Continuous operation Temperature range operation - 25... + 55 C storage - 25... + 85 C altitude < 2.000 m Clearance and creepage distances rated impuls voltage / pollution degree 4 kv / 2 (basis insulation) IEC 60 664-1 EMC IEC/EN 62 061 Interference suppression Limit value class B EN 55011 Degree of protection Housing IP 40 IEC/EN 60 529 Terminals IP 20 IEC/EN 60 529 Housing Thermoplastic with V0 behaviour according to UL subject 94 Vibration resistance Amplitude 0.35 mm frequency 10... 55 Hz, IEC/EN 60 068-2-6 Climate resistance 25 / 055 / 04 IEC/EN 60 068-1 3 08.03.16 en / 657

UL-Data The safety functions were not evaluated by UL. Listing is accomplished according to requirements of Standard UL 508, general use applications Nominal voltage U N Ambient temperature Switching capacity NO contact NC contact Wire connection nfo CSA-Data AC/DC 24 V -15 +55 C Pilot duty B300 5A 250Vac G.P. 5A 24Vdc 5A 250Vac G.P. 5A 24Vdc 60 C / 75 C copper conductors only AWG 20-12 Sol Torque 0.8 Nm AWG 20-14 Str Torque 0.8 Nm Technical data that is not stated in the UL-Data, can be found in the technical data section. Nominal voltage U N Ambient temperature AC/DC 24, AC/DC48V, AC110V, AC0V -15 +55 C Characteristics I 2 2 (A ) th 100 80 60 40 25 20 0 10 20 30 40 50 60 AC/DC 24 V AC 0 V quadratic total current AC/DC 24 V und AC 0 V I =I +I +I +I 2 2 2 2 2 th th1 th2 th3 th4 I, I, I, I thermal current I on contact rows th1 th2 th3 th4 th Total current limit curve M6995_a T( C) device mounted on distance with aircondition device mounted on distance with aircondition device mounted without distances heated by devices with same load Switching capacity 3A 0Vac Wire connection 60 C / 75 C copper conductors only AWG 20-12 Sol Torque 0.8 Nm AWG 20-14 Str Torque 0.8 Nm Technical data that is not stated in the CSA-Data, can be found in the technical data section. nfo Standard Types BG 5924.48 AC/DC 24 V Article number 0050982 Output 3 NO, 1 NC contacts Nominal voltage U N AC/DC 24 V Width 22.5 mm IP 5924.48 AC/DC 24 V 50/60 Hz Article number 0053262 Output 3 NO, 1 NC contacts Nominal voltage U N AC/DC 24 V Width 70 mm Variants BG 5924. /60 BG 5924. /61 BG 5924. /100 BG 5924. /110 BG 5924. /207 with CSA approval with UL approval with fast auto-start voltage range with expandable tolerance 0.85... 1.15 U N special terminal arrangement, (see Circuit Diagrams), for AC/DC 24 V or AC 0 V Ordering example for Variant BG 5924.48 / _ AC/DC 24 V IP 5924.48 AC 0 V Nominal voltage Variant, if required Contact Type Nominal voltage Contact Type 4 08.03.16 en / 657

Application Examples L1(+) L1(+) K3 E-Stop ON E-stop ON K4 (+) 33 41 (+) 33 41 BG5924, IP5924 BG5924, IP5924 N(-) (-) 34 42 M6993_a (-) 34 42 K3 K4 Single channel emergency-stop circuit without feed back loop, with or without automatic restart. For automatic restart terminals - must be linked. No ON-pushbutton necessary. Single channel emergency-stop circuit without feed back loop, with or without automatic restart. For automatic restart terminals - must be linked. No ON-push button necessary. Suited up to SIL2, Performance Level d, Cat. 3* N(-) M6994_b Contact reinforcement by external contactors, 2-channel controlled. For currents > 5 A the output contacts can be reinforced by external contactors. Functioning of the external contactors is monitored by looping the NC contacts into the start circuit (-). Suited up to SIL2, Performance Level d, Cat. 3* L1(+) N(-) emergency stop on (+) 33 41 BG5924, IP5924 (-) S21(-) 14 24 34 42 M11545 Two-channel emergency-stop circuit without feed back loop, with or without automatic restart. For automatic restart terminals - must be linked. No ON-push button necessary. Suited up to SIL3, Performance Level e, Cat. 4 * Suited up to SIL3, Performance Level e, Cat. 4 for E-stop systems according to IEC 60947-5-5, under the following conditions -- A maximum number of operations for the E-stop button is observed -- The E-stop button and the E-stop module are installed in the same cabinet 5 08.03.16 en / 657

6 08.03.16 en / 657