MSA Fixed Gas & Flame Detection for the Water & Wastewater Industries



Similar documents
MSA Fixed Gas & Flame Detection for the Oil, Gas & Petrochemical Industries

Ultima X Series Gas Monitors

sierra monitor corporation Fire and Gas Detection Systems

Ultrasonic Gas Leak Detection

P R O D U C T S P E C I F I C A T I O N MSA Ultima X Series Sensor/Transmitter Specification

Q U A D S C A N I I GENERAL User Interface Enclosure Display QUADSCAN II Temperature Range RECEIVER DISPLAY Sensor Weight Optional Relay Enclosure

TABLE OF CONTENT

Application Requirement

PortaSens ll G AS DETECTOR

ABSTRACT INTRODUCTION

Buckeye Detection Systems Fixed Detection Systems Application Survey

AGRI-ALERT 128 TOUCH AGRI-ALERT 800EZE ALARM SYSTEMS

Section TELEPHONE AUTOMATIC DIALER SYSTEM

Automated Test System SIMPLICITY COUNTS MSA s New GALAXY GX2 Automated Test System / Advanced Safety Management Effortless Operation

Ammonia Detection System Codes and Design Specifications

How to Select a Flame Detector

FLARE MONITORS FLARE MONITOR (FM) PILOT MONITOR (PM) FLAME INTENSITY (FI)

Engineering Specifications XNX Universal Transmitter

Outline. Background. NFPA 820 Applicability to Wastewater Treatment Facilities. Hazardous Area Classifications. Treatment Plant Area Classifications

Continuous Monitoring of Flue and Combustible or Hazardous Gases and Vapors

Environmental Equipment, Inc. IMR 5000 Continuous Flue Gas Monitoring System IMR 5000

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter

Tank Gauging & Inventory Management Solutions

Chlorine Gas Detection System Operation & Maintenance

The Ambient Air Monitoring System

EMERGENCY VAPOR SCRUBBER SYSTEMS

Lockout Specification BW Clip Maintenance-free single gas detector

Metering for today s systems

SAFETY AND HEALTH PROGRAM

Thermal Mass Flow Meters

F ox W hi t e Paper. Reduce Energy Costs and Enhance Emissions Monitoring Systems

How To Use An Irius Pid Detector

Repeaters and Mimics Data Sheet

Alarm Systems. Peace of Mind. Agri-Alert alarms have been protecting swine operations across the world since automated production systems

Flame detection across the spectrum. Range Brochure

Sieger Searchpoint Optima Plus

WIRELESS INSTRUMENTATION TECHNOLOGY

Hydrogen Detection in Oil Refineries

Interface Level And Point Level Analyzers & Sensors

ALTAIR 5X Multigas Detector Bid Specification

SECTION NOx, CO AND NATURAL GAS DETECTION, MONITORING AND ALARM CONTROL SYSTEMS

Natural Gas Well Automation using Kingfisher RTU Products

Global Gas Detection and Monitoring Solutions

Natural Gas Emergencies

FIRE ALARM SYSTEM TECHNICAL SPECIFICATIONS Page 1 of 10

Fire detection equipment

Residential & Commercial Alarm Systems by Gross Security, LLC

Online Infrared Flue Gas Analyzer Gasboard 3000

Electronic Flow Switches

Early Warning Fire Detection and Integrated Security Solution. System Overview

Link 2 Vehicle Maintenance System

How To Use Safety System Software (S3)

Features: RMU REMOTE MONITORING UNIT AND WEB-BASED SOFTWARE

Process gas chromatographs. Measurement made easy. Compliance Solutions for 40CFR60 Subpart Ja

Energy Monitoring Solutions

KACO-monitoring. onlinecomponents.com. Integrated monitoring available. Monitor up to 32 inverters per prolog. Reliable and accurate data

Mass Flow Meter Product Guide

SM6 Series Circuit Breaker Monitors CONSOLIDATED. Electronics, Inc. MONITORING THE FUTURE

Portable Gas Analyzer with Wireless Transmission of Gas Concentrations and GPS Coordinates

1/2 NPTM mm Nose cone fitting Ideal for clean liquids

Pump Controller Type ABS PC 441 Monitoring and/or Control of Pumps and Pumping Stations

SITRANS F M MAG 8000 Precise Metering with battery powered water meters. sitrans f

Linear Heat Series. Fiber Optic Linear Heat Detection System. Tunnels & Metros. Conveyer Belts. Parking Lots. Manufacturing Warehouse Facilities

Relative Humidity Sensors, Transmitters and Calibration Products Relative Humidity Measurement and Calibration

VEGAPULS PULSE RADAR FOR LEVEL MEASUREMENT VEGAPULS 60 SERIES

RGC-IR Remote Gas Calibrator for IR400

Electronics Ltd. Presenting. Power, Intelligence... with a sense of feeling

DET-TRONICS SPECIFICATION DATA. Eagle Quantum Premier Fire and Gas Detection / Releasing System APPLICATION FEATURES

Temperature & Humidity SMS Alert Controller

S4000TH HART. HART Communication Manual

Tank Level Gauging, Safety Equipment & Inventory Management for Alcohol and Beverage Applications

Single-Gas Detector. Long-term solution. h Class I, Div. 1, Gr. A, B, C, D NCL-EN

Data Logging Solutions from Lascar Electronics

Product Guide. Total Solution Provider for Gas and Flame Detection. Because every life has a purpose...

REMOTE TELEMETRY UNITS FOR CONTINUOUS WATER QUALITY MONITORING: AN EXAMPLE FROM SILVERSTREAM LANDFILL Mike Millar, Geotechnics Ltd ABSTRACT

AUROLEX. Plug and Play Monitoring. The best ways to achieve a cleaner, safer environment

PolyGard Carbon Monoxide CO Transmitter ADTX3 1110

key- precision Tecum cuil Ludere ipsae. Possem Precision level detection When space and price matter Pointek CLS 100

Experion Integrated Fire & Gas Safety and Security Monitoring at your fingertips! Ajay Varghese

25 Years of Manufacturing Excellence. Premier Quatro Addressable Fire Alarm System. Assessed to ISO 9001: 2008

PRODUCT LIST Facility DDC Access WebXL DDC

Power consumption (kw)

Gas detectors for the Fire Service

BURGLAR ALARM SYSTEMS BURGLAR ALARM SYSTEMS BURGLAR ALARM SYSTEM EURO ALARM WIRELESS BURGLAR ALARM SYSTEM OASIS

Distributed Temperature Sensing - DTS

EX 2000/EX 2000 C/ GD 2000/GDP

Galaxy Flex SECURITY THAT FITS WITH YOUR BUSINESS AND LIFESTYLE. Protect your property

PIEZOMETER AIRFLOW MEASURING RING

FIRE ALARM SYSTEM. reliable fire detection and alarm signalling system

DIALER SPECIFICATION VERBATIM MODULAR SERIES VSS

Combustible Gas Safety Monitoring: Infrared vs. Catalytic Gas Detectors

Touchpoint Pro. Flexible Gas Control System

LNG Monitoring. Fiber-Optic Leakage Detection System. Pipeline leakage detection. Regasification and liquefaction monitoring

Alliance System Ordering Guide

Liebert COMPREHENSIVE DETECTION OF WATER BASED LEAKS IN CRITICAL SPACES. Liebert Liqui-tect. M o n i t o r i n g S o l u t i o n s

Genesis II. revolutionise monitoring. Why Tutela Genesis II. delivering medical monitoring worldwide

Fluke Digital Multimeters Solutions for every need

EVOLUTION Thermal Imaging Camera Remote Wireless Video Receiver System

Transcription:

MSA Fixed Gas & Flame Detection for the Water & Wastewater Industries A Passion for Safety Every day thousands of municipal and government employees as well as private contractors face many risks working in and around water and wastewater treatment plants. Potential risks include fire and explosions due to hazardous gases and are present regardless of facility size. MSA offers a full line of industry-leading technology to provide detection solutions for water and wastewater facilities monitoring. Providing the best products, service and support in the industry. That s the MSA passion. Because every life has a purpose...

Fixed Gas & Flame Detection for the Water & Wastewater Industries Ultima X Gas Monitors The Ultima X Gas Monitor Series features the latest mechanical, electrical and infrared technologies, designed for exceptional performance. These monitors are well-suited to indoor and outdoor applications in virtually any industry including offshore, refineries, chemical and petrochemical facilities, steel mills, water and wastewater plants, mining, and general industry. Advanced features of the Ultima X Gas Monitor include: Sensor disconnect under power (proprietary feature) allows for sensor change-out without declassifying a hazardous area. Interchangeable, pre-calibrated smart sensors are ready for installation out of the box and can be field-replaced without tools. Liquid crystal display alternates between sensor reading and gas type, indicating ongoing diagnostic checks such as sensor end-of-life condition. Stainless steel and NEMA 4X polycarbonate enclosures are designed to allow sensor to be mounted separately from transmitter electronics for proper sensor placement, and provide easy display access for calibration from a safe location. Infrared point gas detection for continuous monitoring of combustible gases and vapors. Operation using dual wavelength-heated optics technology provides definitive compensation for temperature, humidity and aging effects. IP67-rated (dust-proof, protected from temporary water immersion) to withstand rugged demands of water and wastewater industries. 10-year IR source warranty helps to reduce cost of ownership, increases reliability and reduces maintenance. Optional quick-check LEDs and 4 relay outputs allow for increased indication of alarm and fault conditions. Wireless Communications Combustible and toxic gases can leak virtually anywhere, and leaks may not occur near a facility s gas detection instrument installation area. MSA s Wireless Communication System is an ideal solution for gas detection needs at locations where no infrastructure exists. 900 MHz radio that communicates to a gateway provides reliable real-time detection data at distances of up to 1 mile with clear line of sight. Accepts both analog and Modbus inputs. Power options include solar panel, battery and charger to help ensure up to 2 weeks of autonomous operation. Wireless HART adapter can be added to any MSA HART-enabled field device to communicate with any existing wireless HART network.

Ultima X3 Technology X3 Technology brings multi-sensing and Modbus RTU output to Ultima X Series Gas Monitors. Sensors can be installed remotely up to 3000 ft. from the transmitter. Modbus Systems can handle up to 31 monitors with up to 3 sensors per transmitter for a total of 93 sensors. Scrolling display monitor scrolls through type and reading for all attached sensors. Use of Modbus RTU digital communications allows these transmitters to be wired in series, thus reducing overall installation cost. 3 Ultima OPIR-5 Open Path Gas Detector Open path IR gas detector provides continuous monitoring of combustible gas concentrations at path length of up to 150 meters. Dual detection range enables sensitivity to both small (ppm meter) and large (LEL meter) gas leaks. Parts-per-million meter allows for fast detection of low level leaks. Performance-approved for use in harsh environments (-67 F/-55 C). Multiple communication outputs (Analog, HART, Modbus, AMS support) provide complete status and control capability in the control room. Unitized display for ease of operation and reduced cost. Alignment of open path unit via integrated display has never been so easy. Automatic gain control compensates for dirty optics, rain and fog. www.msagasdetection.com

Fixed Gas & Flame Detection for the Water & Wastewater Industries FlameGard 5 Series Flame Detectors Two Models FlameGard 5 MSIR Flame Detector Great for outdoor applications Combines precision multi-spectral infrared (MSIR) sensing array with highly intelligent neural network processors for high accuracy through superior false alarm immunity. FlameGard 5 UV/IR Flame Detector Great for indoor applications Uses ultraviolet and infrared technologies for flame detection. Features that set the FlameGard 5 Series apart: Multi-spectral infrared sensing array (FlameGard 5 MSIR Detector) with highly intelligent neural network processors provides high accuracy through superior false alarm immunity MSIR sensor array for a range up to 230ft. Wide field of view SIL3-suitable products Continuous Optical Path Monitoring (COPM) checks optical path integrity and electronic circuitry once per minute FlameGard 5 Test Lamp provides easy functionality verification of any FlameGard 5 Detector. Controllers TriGard Gas Monitor for Chlorine and Sulfur Dioxide TriGard Gas Monitor detects chlorine, sulfur dioxide, other toxic gases, remote combustible gases, and oxygen deficiency or enrichment. These monitors are designed specifically for water and wastewater applications. MSA TriGard Gas Monitor offers affordable monitoring solutions for a variety of needs. Adjustable range Multiple sensor mounting options AC- or DC-powered On-board relays NEMA 4X design LCD display with highly visible LED indicators Piezo horn with horn silence button Long-life, MSA-designed sensors Simple pushbutton calibration Available as single-point or 3-point unit Battery backup (optional) Advanced features include sensor disconnect under power, interchangeable smart sensors and onboard LEDs and relays.

GasGard XL Controller Versatile, easy-to-use wall-mounted controller monitors toxic and combustible gases and oxygen deficiency. Compact durable housing is constructed of fire-retardant ABS plastic. Large and clear multi-language LCD display provides real-time target gas readings and events, offers full system diagnosis and is supported by individual LEDs per channel with common relays and internal buzzer. GasGard XL Controller can be easily configured to accept up to 8 remote gas sensors. Fully configurable via USB or RS485 Modbus connection and free software Event log upload through isolated Ethernet RS 485 or USB Multi-language display selectable via controller menu Expandable up to 8 independent channels using plug-in boards Dedicated keys make all functions accessible from front panel Common relay board for Alarm Level 1 and 2, Horn 1 and 2 or Failure Optional 2 additional relays per channel Large graphic display with intuitive icons; all channels shown at a glance Internal buzzer 85 db 5 www.msagasdetection.com

Fixed Gas & Flame Detection for the Water & Wastewater Industries GasGard 100 Control System New GasGard 100 Control System provides easy user interface, intelligent architecture and innovative functionality. System offers a scalable, high performance data acquisition/data logging platform with an intelligent approach to data acquisition and control. Form a complete gas detection solution by equipping GasGard 100 Systems fully integrated measurement, display and recording platforms with MSA's extensive line of transmitters and sensors. Open Ethernet connectivity with Web-based configuration and data monitoring functions lets controller handle many monitoring and historical logging functions. See real time trends with your Web browser from any PC without specialized software! Data monitoring and reporting functions allows for customized reports and layout configurations for viewing trending analysis and more. Use email alert feature to view continuous plant status updates for times when you can't be physically present. Flexible, modular architecture manages anywhere from one to six measurement modules on the backplane each GasGard 100 Controller serves as a measurement node, avoiding long, dense sensor leads throughout machines or processes. ModCon 75 Controller Controller for use with Ultima X Gas Monitor with X3 Technology enables self-configuration, saving time and money. Pre-programmed, self-configuring controller monitors up to 25 Ultima X Gas Monitors with X3 Technology transmitters (75 sensors total). Compact unit offers remote control for many features. RTU input/output and over-ethernet interface capability. All pertinent data displays on main data screen 7-year battery backup provides memory and real-time clock Up to 9 zone relays are standard Remote relay option allows for local alarming

Custom Systems MSA can create a custom system for your specific application. Tri-Gas Sample Draw System Areas of wastewater treatment plants that are subject to flooding such as wet wells and influent headworks, are ideal for MSA's Tri-Gas Monitor sample draw custom system. The system is ideal for monitoring oxygen, hydrogen sulfide and combustible gases (methane or petroleum vapors). In addition, system is specifically designed for optimum performance in high-moisture environments. MSA's Tri-Gas Monitor sample draw system consists of up to 3 sensors with Ultima X or X3 Technology digital communications (RTU output) with onboard LEDs and relays to provide local alarms. Options: 1 or 2 top-mounted beacons Combustible IR sensor Federal, side-mounted horn Heated enclosure 4X stainless steel enclosure Additional common dry contacts Available with discrete 4-20 ma output Scrubber Monitoring System With increased concern for clean air, many wastewater treatment plants have added air scrubber systems to help control odors from hydrogen sulfide emissions. MSA offers both in-situ-type sensors for large diameter pipes and/or pre-engineered sample draw systems for those applications that require higher detection ranges up to 500 ppm. Both of these products can also be used in chlorine scrubber applications with range of 0-25 ppm. MSA Ultima X or X3 Sensor/Transmitters with duct-mount kit feature remote calibration for use within larger pipes. All advanced features of Ultima X or X3 Monitors are available, including smart sensors, onboard relays and LEDs, internal power supply option, and true 1-person calibration. 7 The MSA Scrubber Monitoring System is a pre-engineered system that is compatible with most wet or dry scrubbers. System operates within a closed loop so that no gas vents to the atmosphere. Built to withstand harsh outdoor environments, unit is housed in a heated NEMA 4X enclosure. Maintenance and calibration are simple procedures. If an obstruction occurs in the sample line, unit provides flow failure indication. Calibration can be performed with IR calibrator, eliminating the need to open the system s front door. Benefits: Ensures that your scrubber functions and meets EPA requirements. Indicates breakthrough for carbon bed scrubbers. Controls chemical feeds for wet scrubbers. Conserves expensive chemicals. Eliminates odor complaints from the community. www.msagasdetection.com

MSA Fixed Gas & Flame Detection Systems are designed to help our customers meet NFPA Standard 820 as indicated below. Hazard Location Flame Detection Methane Oxygen Hydrocarbon Chlorine Hydrogen Sulfide Carbon Monoxide Carbon Dioxide Sulfur Dioxide Ammonia ANAEROBIC DIGESTERS, BOTH FIXED & FLOATING COVER* DIGESTER CONTROL BUILDING DIGESTER GAS PROCESSING ROOMS UNDERGROUND (PIPING) TUNNELS CONTAINING NATURAL OR SLUDGE GAS PIPING IN-VESSEL COMPOSITING* ALCOHOL STORAGE INCINERATORS CHLORINATION ROOM CHLORINE STORAGE TANKS & ROOM AMMONIA STORAGE TANKS & PIPES DE-CHLORINATION PROCESSES SULFUR DIOXIDE STORAGE TANKS WET WELLS (STORM WATER, RESIDENTIAL WASTEWATER) PUMPING STATIONS COURSE & FINE* SCREEN FACILITIES FLOW EQUALIZATION TANKS* GRIT REMOVAL TANKS* PRE-AERATION TANKS* PRIMARY SEDIMENTATION TANKS* OXYGEN AERATION TANKS SCUM HANDLING BUILDING* SCUM PITS* SCUM PUMPING AREAS* WET & DRY SIDE SLUDGE THICKENER* SLUDGE STORAGE AREAS* SLUDGE BLENDING TANKS* AND HOLDING WELLS ODOR CONTROL SYSTEM ACCESS COMPOSTING PILES DEWATERING BUILDINGS ANAEROBIC DIGESTION GAS STORAGE UNDERGROUND (PIPING) TUNNELS NOT CONTAINING NATURAL OR SLUDGE GAS PIPING *If building is enclosed. Note: This bulletin contains only a general description of the products shown. While uses and performance capabilities are described, under no circumstances shall the products be used by untrained or unqualified individuals and not until the product instructions including any warnings or cautions provided have been thoroughly read and understood. Only they contain the complete and detailed information concerning proper use and care of these products. ID 07-2079-MC / December 2013 MSA 2013 Printed in U.S.A. Corporate Center 1000 Cranberry Woods Drive, Cranberry Township, PA 16066 USA Phone 724-776-8600 www.msasafety.com U.S. Customer Service Center Phone 1-800-MSA-INST Fax 1-800-967-0398 MSA Canada Phone 1-800-672-2222 Fax 1-800-967-0398 MSA Mexico Phone 01 800 672 7222 Fax 52-44 2227 3943 MSA International Phone 724-776-8626 Toll Free 1-800-672-7777 Fax 724-741-1559 Email msa.international@msasafety.com Offices and representatives worldwide For further information: www.msasafety.com