Poro Lintel System Range Unique to the Porotherm & thin joint masonary systems



Similar documents
CI/SfB (31.9) BETTER BY DESIGN PRODUCT GUIDE COMPLETE GUIDE TO THE IG PRODUCT RANGE.

Rockwool Flexi Insulation Application Guide

Understanding BS EN 771-3: Aggregate concrete masonry units

Baumit Renders for Porotherm Masonry. Application Guidelines. n Light and easy application n Tried and tested

Module 3.7. Thermal bridging

CI/SfB (31.9) BETTER BY DESIGN LINTEL GUIDE SPECIFIER S GUIDE TO OUR RANGE OF LINTELS.

Lintel Product Selector

PRODUCT GUIDE lower tolerances high quality

Section 5.0. Basements. Wall insulated externally. Wall insulated internally. Ba02. Product: Polyfoam ECO Floorboard Ba01.

INTERIOR WALLS AND BASEMENTS CHOOSING THE RIGHT MEMBRANE FOR INTERIOR WALLS. Multi-Layer Technology provides increased strength.

The right solutions. However, it is inevitable that with the introduction of any new construction system the question arises How does it compare?

PRODUCT GUIDE. Building the future with Ytong autoclaved aerated concrete. low tolerances high quality

MASONRY SUPPORT & WINDPOST SYSTEMS

Monocouche Best Practice Guide. New-Build Housing Managing movement to avoid cracking

Multi-layer Insulation Blanket for Roofs

THE DEVELOPMENT OF DESIGN METHODS FOR REINFORCED AND UNREINFORCED MASONRY BASEMENT WALLS J.J. ROBERTS

Partitioning & Ceiling Product Information

fischer Test Report Fixing Tests for Wienerberger Porotherm blocks

Dubai Municipality Standard DMS 1: Part 5: 2004

Introduction & Principles Issued in support of Junction Details, Parts 1 to 5

The Warm Edge for insulating glass

Built-up roofing solutions with rigid insulation boards on concrete decks for new-build and refurbishment E-a5

Solid shape molding is not desired in injection molding due to following reasons.

ENERGY EFFICIENT WINDOWS & DOORS A GUIDE TO THERMAL PERFORMANCE. Building Solutions Automotive Industry

Section Timber Frame Walls. Single layer between studs. Single layer between studs with service void. Between studs with insulated lining

22-23 October 2012 Trondheim, Norway

ENVIRONMENTAL INFORMATION APR 1200 products are made from glass mineral wool, one of the most environmentally friendly insulants available.

Saint Gobain Gyproc India Ltd. (Formerly India Gypsum Ltd.)

Fire 2This Technical Bulletin has been commissioned by the UK SIP Association in

SOUND INSULATION FOR EXTERIOR WALLS AND FACADE SYSTEMS

Composite Panel Firewall Systems

OIL-X EVOLUTION Compressed Air Filters ENGINEERING YOUR SUCCESS. TECNI-AR Ltda - Tel: w.tecni-ar.com.br

FIXIT.CH. Aerogel Insulating Plaster System. Handling Guidelines. Easy to use. Mineral based W/mK BAUSTOFFE MIT SYSTEM

Unbeatable energy efficient glass curtain wall system

Timber Frame Walls Rethinking Construction

Steel Solutions for Green Building

Tunnels & Arches OLDROYD THE ULTIMATE WATERPROOF MEMBRANE SYSTEM

BEST PRACTICE GUIDE. Fibrelime Premixed Universal Plaster and Render

Contents. APA Construction Details. Full fill cavity walls Partial fill cavity walls Solid externally insulated walls 26-37

How To Design A 3D Print In Metal

Pilkington Activ self-cleaning glass. The clear choice for your conservatory.

The Kingspan Insulation Price List 1 st January 2013

WARMFILL CAVITY WALL INSULATION WARMFILL CAVITY WALL INSULATION FOR MASONRY CAVITY WALLS

Thermal Imaging Test Target THERMAKIN Manufacture and Test Standard

Is an air source heat pump the right choice for my home? Important information and key things to consider before installing an air source heat pump

GUIDANCE SHEET FOR CONSERVATORIES, SUNROOMS AND EXTENSIONS TO DWELLINGS.

European Technical Approval ETA 13/0526

Insulated Roof & Wall Panels. Product Data Sheet. Trapezoidal Insulated Roof Panels KS1000 RW

FACTORS AFFECTING ENERGY CONSUMPTION OF BUILDINGS

POLYURETHANE FOAM CONCEPT

Interior Pocket Door System. A hiding gliding sliding door

A few good reasons to have a conservatory. The conservatory structure

Rockwool Cladding Roll

HEALTHY LIVING WITH WOOD FIBRE INSULATING MATERIALS

European Technical Approval ETA 13/0384

STENCA PIPE. High quality pipe insulation.

YTONG Product list.

LAYING BLOCK AND BRICK

Foam Injection Molding:

Facts About. Industrial gases for better injection molding. This article appeared in the trade journal Kunststoffe plast europe, issue 12/2004.

Construction. 3-part thixotropic epoxy patching mortar. Product Description. Tests

Twiga Insul. India's Leading Thermal and Acoustic Insulation. Insulating India

What a good idea! Turn your conservatory into an all-year-round living space.

WALLS Three common wall types are described below, with their insulation solutions.

Voltage optimisation Reducing energy, saving money

K17.12 Door closers K17. Doors

OLDROYD. Interior Walls. Interior Walls. below and above ground. below and above ground

Solar Homes Catch the Sun. Are you planning a new house? Discover how you can apply solar architecture principles to:

Mold Preventing I nterior System

If stepping is required, step at 180mm as seen in this picture.

Fire Resistant Systems

INJECTION MOLDING PROCESSING GUIDE Polymer

Universal systems for frameless doors

The BASA Guide to the ISO Classification of Sealants for Building Construction

Mandate M/116 MASONRY AND RELATED PRODUCTS

BUILDING CONTROL GUIDANCE SHEET USE OF BREATHABLE ROOFING FELTS.

Section 4.3. Separating Floors. Timber frame floor with I-Beams. Upgrading existing timber floor with new ceiling. Timber frame floor with

MEASUREMENTS OF THRUST LOAD IN CABLE SYSTEMS SEMI-RIGIDLY INSTALLED IN DUCT / MANHOLE STRUCTURES

PTFE Slide Bearings 04/10 149

Pilkington Activ self-cleaning glass. The clear choice for your conservatory.

CITADEL. & AX-S Steel Covers. it s about time.

Extra Low Energy Housing in Ireland How far should we go to the Passive House? Jonathan Jennings Head of R&D Kingspan Century Homes

MERO Access Floor / Floor systems for data centers * *Ready for Cloud-Computing

CURRENT RATINGS MORE THAN A CABLE

A GUIDE TO CHOOSING THE RIGHT LIME-BASED PRODUCTS FOR RESTORING MASONRY

Waterproofing Solutions

Improving the flood resistance of your home. Advice sheet 4: Flood-resilient walls.

19 Examples of Wall Insulation

Section 2.4. Built-up Metal Roofs. Rail and bracket system. Standing seam system. Bu02. Product: Earthwool FactoryClad range Bu01

0331 Brick and block construction

Schlüter -KERDI-BOARD Substrate, structural panel, bonded waterproofing

MERO Floor Systems - CleanRoom

Miracel 19 rack platform for data center, telecommunication and network technology. Rack & Integrated Enclosure Systems

How To Certify The Scottsdale Construction System

FLAME CuTTIng te la P is utting B c

The Real Value of Space

Hanson Building Products. precast basement solutions

FIRE PERFORMANCE OF STRUCTURAL INSULATED PANEL SYSTEMS

Rooflighting and Glazing

Transcription:

Poro Lintel System Range Unique to the Porotherm & thin joint masonary systems keystonelintels.com

Finding better ways to build for tomorrow The Keystone Group are Europe s leading steel lintel manufacturer. Keystone have worked closely with Wienerberger to design, test and manufacture a bespoke range of lintels for the Porotherm and other thin joint systems. Porotherm is a registered Trademark of Wienerberger AG and is used with their permission What is Porotherm? What are the benefits of using the Porotherm? Porotherm is a precision engineered modern clay block walling system. The system has revolutionised the construction industry through fast and dry construction with the benefits of high strength and thermal performance. Through the use of 1mm mortar beds using the special adhesive in comparison to the conventional 10mm joints, the Porotherm System brings many benefits associated with efficiency, quality and value retention. With the continuous updates to UK regulations and the target for zero carbon homes, the benefits of using the Porotherm System will be rewarding through the enhancement of thermal performance and the reduction of Carbon emissions through the buildings life. The Porotherm system enables accelerated construction where fast, dry construction is required with the retention of higher strength, thermal and acoustic efficiency properties. Speed of the process Virtually dry construction, using the special adhesive utilising minimal water, results in rapid drying with less shrinkage and cracking and fewer movement joints allowing for no delay for the finishing trades. Efficiency Porotherm evens out temperature variations through thermal capacity effects, to protect against cold in winter and ensure a comfortable and healthy room in summer. The fast drying properties optimise thermal protection, whilst the gradual release of passive solar energy reduces heating costs. Strength and Flexibility The Porotherm block has the compressive strength of 10 N/ mm2 which results in high stability performance. Achieving such strength, the Porotherm system can be used on both external cavity walls and internal partition walls. Safety The Porotherm blocks are lightweight in comparison to aggregate allowing for the ease of use and handling. Reduced dermatological risk is offered with the Porotherm system as the clay block material is less irritant.

POROTHERM & THIN JOINT MASONRY LINTEL RANGE Keystone have developed two Lintels that are unique to the Porotherm and Thin Joint Masonary Systems. These unique lintels offer a perfect cost effective solution that also enhance the thermal performance of a building. Both of these Lintel options have been specifically designed to allow construction of the inner skin independently of the outer leaf. Only the Poro Lintels unique design enables this retrospective connection between the inner and outer leaf support lintels. Poro-Cav Lintel The Poro-Cav lintel features a unique, patented thermal break plate that aids to ensure the thermal performance of the wall is maintained. With the outer part of the lintel fully insulated, it closes the cavity removing the need for additional cavity closers. The inner leaf is supported through a standard Keystone Box lintel whilst the outer leaf support comes from the uniquely designed outer lintel. As it is a two part lintel, the outer leaf can then be installed without the need for supportive propping. Z/K Lintel The Z/K lintel is made up of a box lintel inner and a specially designed Z/K outer which offers more stability and rigidity than the conventional angle lintels. The Z/K outer is fitted with profiled integral insulation ensuring continuity of insulation in the cavity with no air voids. The insulation also eliminates the need for additional cavity closers, saving time and money. The Z/K Lintel system has a remarkable thermal performance with a Psi value of 0.032w/mk.

PORO LINTEL SYSTEM Poro-Cav Lintel 100 Wide Inner Leaf Cavity 100 Manufactured Length 600 10 2550 2850 Manufactured Length 1800 2400 2700 3000 Height H 150 150 150 220 Internal Leaf Total UDL (Kn) 16 19 22 25 Nominal H External Leaf Total UDL (Kn) 5 8 9 12 Perforated Specify Poro-Cav/50mm (for 50 to 65mm Cavity) Poro-Cav/75mm (for 70 to 85mm Cavity) Poro-Cav/100mm (for 80 to 100mm Cavity) Poro-Cav lintels also available for wider cavities Poro-Cav Lintel 140 Wide Inner Leaf Cavity 140 Manufactured Length 600 10 2550 2850 Manufactured Length 1800 2400 2700 3000 Height H 150 150 150 220 135 Nominal H Internal Leaf Total UDL (Kn) 18 25 30 35 External Leaf Total UDL (Kn) 5 8 9 12 Perforated Specify Poro-Cav/50mm/140WIL (for 50 to 65mm Cavity) Poro-Cav/75mm/140WIL (for 70 to 85mm Cavity) Poro-Cav/100mm/140WIL (for 80 to 100mm Cavity) WIL = Wide Inner Leaf Poro-Cav lintels also available for wider cavities Poro-Cav Lintel 190 Wide Inner Leaf 100 Cavity 190 180 Manufactured Length 600 10 2550 2850 Manufactured Length 1800 2400 2700 3000 Height H 150 150 150 220 Internal Leaf Nominal H Perforated Total UDL (Kn) 18 25 30 35 External Leaf Note: Total UDL For other (Kn) loading Conditions contact 5the Keystone 8Technical Department. 9 12 Specify Poro-Cav/50mm/190WIL (for 50 to 65mm Cavity) Poro-Cav/75mm/190WIL (for 70 to 85mm Cavity) Poro-Cav/100mm/190WIL (for 80 to 100mm Cavity) WIL = Wide Inner Leaf Poro-Cav lintels also available for wider cavities

CPD Online: www.keystonelintels.co.uk/cpd Poro-Box/365 365 External Solid Walls Manufactured Length 600 10 2550 2850 Manufactured Length 1800 2400 2700 3000 Height H 150 150 150 220 Internal Leaf Total UDL (Kn) 18 25 30 35 Nominal H Nominal H External Leaf Total UDL (Kn) 18 25 20 35 180 Perforated Combination of 2 Box Lintels arranged as per the diagram opposite. Also available to suit other solid wall situations, please contact Keystone Technical Department. Specify Poro-Box/365

Z/K LINTEL SYSTEM Consisting of an internal and external lintel Z/K Outer Lintel Manufactured Length in 150mm increments 600 10 1800 2700 Height H 100 175 Thickness 3.2 3.2 Total UDL (Kn) 8 10 Internal leaf can be individually specified to suit loading and wall construction. For use to support the outer leaf of cavity wall construction. (The Z/K outer leaf should be suitably propped during construction). Example of the Z/K Outer in-situ Z/K Inner Lintel BOX/K-100 Manufactured Length in 150mm increments 600 1650 10 2550 2850 3750 4200 1500 1800 2400 2700 3600 4000 4800 Height H 75 150 150 150 215 215 215 150 215 Thickness 2 1.6 2 2 2.5 2.5 2.5 Total UDL (Kn) 18 18 25 20 35 30 24 75 Used to support internal or external openings with 100mm wide walls (Can be insulated as optional extra). Perforated steel for plaster key

CPD Online: www.keystonelintels.co.uk/cpd HDBOX/K-100 Manufactured Length in 150mm increments 600 1350 10 1200 1800 2700 Height H 150 150 215 h nominal Thickness 2.5 2.5 2.5 Total UDL (Kn) 50 45 40 Perforated steel for plaster key For heavy duty loading conditions to support internal or external openings with 100mm wide wall (Can be insulated as optional extra). BOX/K-150 h nominal 145 Manufactured Length in 150mm increments 600 10 2550 285 10 2550 1800 2400 2700 3600 4000 4800 Height H 150 150 150 215 215 215 Thickness 1.6 2 2 2.5 2.5 2.5 Total UDL (Kn) 18 25 20 35 30 24 Perforated steel for plaster key Used to support internal or external openings with 150mm wide walls (Can be insulated as optional extra). HDBOX/K-150 Manufactured Length 600 1350 10 Manufactured Length 1800 2400 2700 Height H 150 150 150 h nominal Thickness 2.5 2.5 2.5 Total UDL (Kn) 50 45 40 Perforated steel for plaster key 145 For heavy duty loading conditions to support internal or external openings with 100mm wide wall (Can be insulated as optional extra).

Quality Keystone devote extensive resources to quality. Lintels are manufactured to the highest quality and continually assessed by the BSI to ensure our quality complies with BS EN ISO 9002:1994. Keystone has also received Investors in People Accreditation. Keystone Lintels are designed and manufactured in accordance with BS EN 845-2:2003. Testing CERAM have carried out independent testing on the Porotherm Lintel range to confirm the information given in the Technical Report and Design Guide for the Porotherm Walling System. Environment Keystone are devoted to contributing to the protection of the environment. Keystone aim to minimise the impact of the manufacturing processes through the use of sustainable practices and continuous improvement in accordance with ISO 14001. GB Sales & Service KEYSTONE - SWADLINCOTE Ryder Close, Cadley Hill Industrial Estate Swadlincote, South Derbyshire DE11 9EU UK: 01283 200 150 F: 01283 223 352 Email: info@keystonelintelsuk.com NI/ROI Sales & Service KEYSTONE - IRELAND Ballyreagh Industrial Estate, Cookstown, Co. Tyrone BT80 9DG NI: 028 8676 2184 F: 028 8676 1011 Email: info@keystonelintels.co.uk ROI: 048 8676 2184 F: 048 8676 1011 Email: info@keystonelintels.ie www.keystonelintels.com ISO 14001 ISO 9001 EMS 5535 FM 21541 CERTIFICATE No 12/48