Cat 5, 6 or 7? Standards. Background. A University Standard for Structured Wiring. Network Points Installed. British Standards.



Similar documents
NUIG Campus Network - Structured Cabling System Standards Information s Solutions & Services (ISS)

The Evolution of Copper Cabling Systems from Cat5 to Cat5e to Cat6 Copper Cabling Standards and Technical Aspects

Specifying an IT Cabling System

European Normative EN system

ANSI/TIA/EIA A, Commercial Building Telecommunications Cabling Standard.

Requirements for Modular Patch Cords (e.g. RJ45 patch cords for Cat5 and Cat6 cabling systems)

IT Services Converged Network Installation Specification:

HIGH SPEED COMMUNICATIONS PLENUM CABLE CATEGORY 5e CMP FEP JACKETED, PVC-FREE UNSHIELDED TWISTED PAIR (UTP)

DIVISION 27 COMMUNICATIONS. A. System design shall be completed by a Registered Communications Distribution Designer (RCDD).

European Standards Reference Guide. A Reference Guide To:

Network Design. Yiannos Mylonas

ANSI/TIA-942 Telecommunications Infrastructure Standards for Data Centers

with Component Rating A Simple Perspective

A guide to connecting to fibre optic networks for homeowners, architects, builders and developers.

Presenters Brett Weiss, Gabe Martinez, Brian Kroeger.

Innovation. Volition Network Solutions. Leading the way in Network Migration through Innovative Connectivity Solutions. 3M Telecommunications

Giganet Copper Cabling Training

SUBJECT: CENELEC VOTE FINAL DRAFT PR EN INFORMATION TECHNOLOGY -GENERIC CABLING SYSTEMS PART 1:GENERAL REQUIREMENTS AND OFFICE AREAS

Technical Information and System Application Guide

Specification SFTP CAT6 Network Cable 23AWG CU

R&Mfreenet Advanced Cat 6 A Unshielded Connection Module

Cabling for 10GBASE-T and Beyond - A Tangled Web

ANSI/TIA-942 Telecommunications Infrastructure Standard for Data Centers

ANSI/TIA/EIA A A Revisited. Residential Telecommunications Cabling Standard (Draft 6/22/99) Larry L. Hamlin, RCDD

IT Cabling Solutions

INTERNATIONAL STANDARD

Cabling Standards Update 2014

Data Center. Pre-terminated. Patch Panel System. Cabling Systems Simplified. Patch Panels. 10G + Gigabit. Patch Cords. Plug & Play Installation

ECONOMICS OF DATA CENTER OPTICS SPIE PHOTONICS WEST INVITED PAPER (9775-2) FEBRUARY 16, 2016

Evolution of Cabling Standards TIA/EIA ISO/IEC CENELEC. by Paul Kish NORDX/CDT Chair TIA TR 41.8

Standard Comms Rooms Specification

Running 1000BASE-T Gigabit Ethernet over Copper Cabling 30 March 1999 Colin Mick/The Mick Group with Bruce Tolley/3Com and Willem Wery/Intel

Information Communications Technology Structured Cabling Infrastructure Guidelines

Performance Verification of GigaSPEED X10D Installations with Fluke Networks DTX 1800 CableAnalyzer

Dat Da a t Cen t Cen er t St andar St d andar s d R o R undup o BICSI, TIA, CENELEC CENELE, ISO Steve Kepekci, RCDD

Standards. 5 ANSI/TIA/EIA-569-A (CSA T530)

Mixed High-Speed Ethernet Operations over Different Categories of Bundled UTP Cable

FiberLAN Optical LAN Solution

Structured and Point to Point Network Cabling for Industrial Automation

Construction Services. Building Strategy. Standards for Wiring Telecommunications Networks in Cornwall Council Buildings. Version 4.

Data Centre Cabling. 20 August 2015 Stefan Naude RCDD The SIEMON Company

This 5 days training Course focuses on Best Practice Data Centre Design, Operation and Management leading to BICSI credits.

White Paper: 10 Gigabit Ethernet over Twisted Pair Copper Systems

Gigabit Ethernet on Copper Cabling Infrastructures

HIGHSPEED ETHERNET THE NEED FOR SPEED. Jim Duran, Product Manager - Americas WHITE PAPER. Molex Premise Networks

Category 6 UTP - Cabling System

Data Center Standards Making Progress on Many Fronts. Jonathan Jew J&M Consultants, Inc

Assuming you currently have a SWGfL solution, is the selected location for the new solution the same as the location of the existing solution?

Implementing Fast Ethernet

Testing 10 Gb/s Performance of Category 6 and 6A Structured Copper Cabling Systems within the Unified Physical Infrastructure SM (UPI)

Trends and Standards in LAN Cabling Systems Intelligent Buildings

How To Set Up A Minipatch System For A Small Office Or Home Use

Issues Affecting the Design and Choice of Cabling Infrastructures within Data Centres

Screened cable and data cable segregation

Telecommunications Infrastructure Standard for Data Centers Tutorial

Implementation Guide for N3 Hosted Voice Services (HVS)

Enhanced Category 5 Cabling System Engineering for Performance

Networks. The two main network types are: Peer networks

Installation Manual For Support Call or

DIVISION 26 - ELECTRICAL SECTION CABLES FOR INSTRUMENTATION

Session 2; Cabling Technology in the Data Centre Media Choices; Copper Twisted Pair

1.1 SYSTEM DESCRIPTION.1 Data system includes data outlets and wiring for office and school applications.

Design Guide. Universal Connectivity Grid. SYSTIMAX Solutions from CommScope

Communication, Signal & Data Cables

Category 6 Solutions. 4. Category 6 Solutions. 09/ IN TrueNet Structured Cabling. Introduction Cable Patch Panels... 4.

Abstract: This document examines the alien NEXT performance of various bundled cables and measures the impact upon various networks performance.

Innovative Connectivity Solution for Maximum Performance and Security

Documenting and Managing Infrastructure Connectivity

Table of Contents. Fiber Trunking 2. Copper Trunking 5. H-Series Enclosures 6. H-Series Mods/Adapter Panels 7. RSD Enclosures 8

Physical Infrastructure trends and certification requirements for Datacenters. Psiber s Global Village

Data and Voice Network Infrastructure

TIA 569 Standards Update Pathways & Spaces. Ignacio Diaz, RCDD April 25, 2012

21 st Century Campus Network Responsibility Matrix 5/26/10

Data Center Optimization: Component Choice. Innovative Design. Enabling Infrastructure

CATEGORY 8: UNDERSTANDING THE NEW CATEGORY OF PERFORMANCE FOR BALANCED TWISTED PAIR CABLE

Data Communication Cabling. Standards and Specifications. Version 4.3

Optical Fiber. Smart cabling: constructing a cost-effective, reliable and upgradeable cable infrastructure for your enterprise network

Discontinued. Volition. Fiber Optic Cable. 3Innovation

Disclaimer This information is collected and composed by QUANG DUNG TECHNOLOGY from Cablingdb.com. All information is copyrighted by Cablingdb.com.

DATA CENTER NETWORK INFRASTRUCTURE. Cable and Connectivity for the Most Demanding Networks. BerkTekLevitonTechnologies.com

TIA-942 Data Centre Standards Overview WHITE PAPER

NTU Data Communications Cabling Specification

An Engineer s Guide to Full Compliance for CAT 6A Connecting Hardware

AMP NETCONNECT Data Center Cabling Solutions

Case Study. Molex PDS Delivers Voice and Data Streams around Shanghai Unicom Tower

Ethernet 301: 40/100GbE Fiber Cabling and Migration Practices

Security & Surveillance Cabling Systems

What is a Datacenter?

Nexus Technology Review -- Exhibit A

Cabling and Building Infrastructure for Technology

Smart Cabling: Constructing a cost effective reliable and upgradeable cable infrastructure for your data centre/enterprise network

What are the requirements for a Home Network?

So you want to build a data centre? Look what s coming from BICSI! Matt Flowerday Capitoline FZC mflowerday@capitoline.org

Information and Communication Technology Network Cabling Infrastructure Standard

Preparing for the NBN. Fixed Wireless Connections

10 Gigabit Ethernet over copper: Unshielded, unprotected?

Transcription:

Cat 5, 6 or 7? A University Standard for Structured Wiring. Background isolutions recently formed Incorporates all IT service providers within the University. Focus on all ICT needs of the user and the business. Uses ITIL management framework. Data Network Team (6 staff) cover 5 academic campuses, 4 Halls of Residence and 9 other sites. Approx 18,000 network points. University Capital Building Programme since 2001 Landmark buildings Major refurbishments Campus redevelopment Simon Lane, Data Networking Manager, isolutions 01 April 2009 2 Network Points Installed Standards 3 Wiring Standards Telecommunications Industry Association TIA / EIA 568B (US) International Standards Organistaion ISO/IEC 11801 (International) CENELEC EN50173 EN50174 (European) BSI BS EN50173 BS EN50174 (UK) British Standards BS EN 50173-1 Information technology Generic cabling systems Part 1: General requirements Identifies the general topology and Channel performance BS EN 50173-2 Information technology Generic cabling systems Part 2: Office premises BS EN 50173-3 Information technology Generic cabling systems Part 3: Industrial premises BS EN 50173-4 Information technology Generic cabling systems Part 4: Homes BS EN 50173-5 Information technology Generic cabling systems Part 5: Data centres 5 6 1

Wiring Topology (EN 50173-1) campus distributor campus backbone cable building distributor building backbone cable floor distributor horizontal cable CD BD BD FD FD FD FD Campus and Backbone cable (EN 50173-1) Likely to be fibre singlemode or multimode 50/125 or 62.5/125 Channel performance designated in the standards OS1, OS2, OM1, OM2, OM3 Choice depends primarily on distance We now specify singlemode everywhere Simplifies choice of optics on equipment Permits through-patching where network distribution layer is not required Cable is cheaper, but optics more expensive 7 8 Horizontal Cable (EN 50173-1) Likely to be copper Unshielded Twisted Pair (UTP) or Shielded (STP) Channel performance designated in the standards Class D, equivalent to CAT 5/5E Class E, equivalent to CAT 6 Class EA, equivalent to CAT 6A Class F, equivalent to CAT 7 Class FA, equivalent to CAT 7A UTP / STP STP Electrical Characteristics of the channel: Return loss ; Insertion loss; Frequency; Delay Skew; Capacitance; Near-end crosstalk loss (NEXT); Power Sum NEXT (PSNEXT); Attenuation crosstalk ratio Power sum ACR (PSACR); loss (ACR); Propagation Delay; Equal level far end crosstalk loss (ELFEXT); Power sum ELFEXT (PSELFEXT); Direct current (d.c.) resistance unbalance; Transverse conversion loss (TCL); Equal level transverse conversion transfer loss (ELTCTL); Coupling attenuation; UTP or STP? STP is going to be more difficult to install correctly UTP STP is more expensive STP installation takes longer Decision: UTP 9 10 Which Class or Category? Look at the applications: POTS, alarms etc Ethernet 10Mbps not very interesting, except legacy end devices Runs over wet string minimum CAT3 / Class C Ethernet 100Mbps used here and there minimum CAT5 / Class D Ethernet 1Gbps our standard office desktop delivery minimum CAT5 / Class D What about 10Gbps Ethernet? 10GBASE-T runs 100m over CAT6A / Class EA or Class F 10GBASE-T runs 55m over CAT6 / Class E 10GBASE-SR runs to 300m over OM3 fibre Already decided not going to have STP Fibre not practical for today s end-systems (or switch port densities) Decision: want to future-proof new buildings, ask for 6A Decision: CAT5 / CAT 5e is adequate at present time 11 12 2

Issues with 6A cable Size of the cables CAT5 5mm CAT6 5.5mm CAT6A 7.62mm 6.5mm x 8.4mm What about bend radius? What about tray and rack capacity? What about cost? Decision: Can t (yet) do 6A even in new buildings (might do 6A in a data centre) 5e 6 6A 7 Summary Install CAT 5e in existing buildings We found CAT 6 difficult to retro-fit Install CAT 6 in new buildings Specify maximum horizontal wiring length 60m Increase number of hub rooms if necessary 13 14 More Standards (1) BS EN 50173-2 Information technology Generic cabling systems Part 2: Office premises More Standards Builds on 50173-1 Specifies Class D (Cat 5E) or higher Adds description of: MUTO (Multi-User Telecommunications Outlet) CP (Consolidation Point) 16 More Standards (2) BS EN 50174-1 Information technology Cabling installation, Part 1: Specification and quality assurance Specifies who does what (designer, installer) The building environment (dust, temperature, humidity) Electromagnetic and power environment Pathways (trays, capacity) Frames, room space layout Safety, testing, documentation, labelling More Standards (3) BS EN 50174-2 Information technology Cabling installation Part 2: Installation planning and practices inside buildings Safety and installation practices Separation of data from power cables Some nice diagrams of how to locate cables into trays Lots of stuff about electrical bonding 17 18 3

Why create a University standard? Because nobody reads the standards in detail Why create another Standard? Because there are still choices and adaptations to be made Because the building project wants a document to issue to the architects, designers and contractors Because of the problems we ve had in the past 20 Issues we ve experienced in the past Hub room shrinks in size very common They needed a bigger kitchen / extra toilet Hub room has no ventilation or aircon Hub room is not finished / full of builders rubble at handover Value engineering determined hub room could be shared space Cable routes not accessible / plastered over Architect demanded a smooth wall / ceiling finish Issues we ve experienced in the past Cabling installed by electrical contractors Needed complete re-termination Not labelled properly Joined and wrapped with electrical tape Over-length wiring Floor boxes in correct place, but on day 1 all the furniture moved by occupants Hopelessly in-adequate number of points installed 21 22 Advice on creating a specification Get someone to create one for you It ll become part of the building contract, it needs to be accurate Approach your preferred wiring company. They may have outline specifications ready to go. Maybe they won t charge you! What s in the Specification? 23 4

Overview of wiring model Telecoms Room Design Reflects the model from the standards Position (within building) Space (min 2.8m * 2.8m) Options for small, medium and large buildings Layout (2 racks = 336 outlets, 4 racks = 672 outlets) Small consolidates functions into 1 hub room Lighting Medium is one BD/FD and one remote FD Ventilation (2 * 10Kw units) Large is for multi-floor buildings; multi FD but not necessarily one per floor Power (2 * 32 Amp commando sockets, 2 * 12-way strips) Security (Locks, opaque windows) Number of outlets per desk (3) False floor / Ceiling void (where fitted) Density of outlets per type of space (e.g. office, lab etc) Cable management (diverse ceiling level tray entry to top of rack) 25 26 Outlet Presentation Ducting and Cable Routing Dado Trunking Specification Tray and trunking size calculations Underfloor (mini-pods) Internal and external duct construction and capacity Power pole Components Stud wall UTP cable part nos. Fibre cable part nos. Patch panel and faceplate part nos. Racks, PDU s Consolidation point 27 28 29 30 Roles and Responsibilities Building Designer Plan hub rooms, data outlets, cable routing, etc. Main Contractor Power, cooling, lighting, ducting, containment, etc. Data Contractor Cable system detail design, supply, install, test. isolutions Technical approval, active networking equipment. Estates and Facilities Project Leader Co-ordination, financial approval. 5

Installation Appoint an installer Using EU OJEC procedure, appointed three suppliers accredited to install our preferred wiring system in 2001 and 2007. Although large building projects undertake their own procurement exercises, these suppliers are usually invited by the building contractor to bid. One supplier was selected by mini-tender to undertake our day-to-day installations, and typically have at least 1 engineer on-site. These are fixed price. Where appropriate (e.g. >20 connections in one place), mini-tender to get a better price. 32 Has it worked for us? Has it worked for us? Yes, but you have to stand firm follow the specification, or no service! Thank you! 34 6