SUGGESTED SPECIFICATION EXHAUST SYSTEM SILENCER, FLEX CONNECTOR, INSULATION BLANKETS, WALL / ROOF THIMBLES



Similar documents
STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM

B. ASTM C 533 Calcium Silicate Block and Pipe Thermal Insulation. C. ASTM C 547 Mineral Fiber Preformed Insulation

SECTION HVAC INSULATION. A. All work specified in this Section is subject to the provisions of Section

Removable Insulation Blankets from A to Z

Marine Exhaust Insulation

Components HVAC General Standards HVAC Guidelines HVAC System Selection Life Cycle Cost Analysis

SECTION HANGERS AND SUPPORTS FOR HVAC PIPING AND EQUIPMENT

Steam System Best Practices Condensate System Piping

RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000

Noise Control. Commercial, Industrial, and Environmental Products and Solutions.

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

Figure 22: Typical Individual Venting. Figure 21: Single Water Heater Venting

SERIES ASM NEOPRENE/EPMD FLANGED SINGLE SPHERE CONNECTOR CONNECTORS. Pressures to 225 PSIG (15.51 barg) Temperatures to 230ºF (110ºC)

TABLE OF CONTENT

ASX7-4-IOM-7 J

Roof Curbs, Extensions and Equipment Supports

Replacement parts. WM97+ gas-fired water boiler Boiler Manual. OBTAIN PARTS ONLY THROUGH WEIL-McLAIN THE BOILER CONTAINS CERAMIC FIBER MATERIALS

BILL OF QUANTITY FOR THE HVAC WORKS OF The Institute of space technology, near Toll Plaza (G.T. Road,) Islamabad

B. Types of mechanical insulation specified in this section include the following:

Enclosures DuraSystems Barriers, Inc. The Passive Fire Protection Specialists

Fiberglas, Exterior Wall Thermal Insulation

4 Installation Requirements

This will also provide you with the knowledge to insure long life for your Investment

CHAPTER 5 WATER HEATERS

DIVISION 00 - PROCUREMENT AND CONTRACTING REQUIREMENTS

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS

SunMor SM-V30 Solar Water Heater Installation Manual

Mobile Home Pre-Inspection Checklist

Gas Stoves. H15-10 Direct Vent Gas Stove. Model H15-NG10 H15-LP10. Approved Venting Systems

FINAL December 2012 SECTION DUCTWORK

Fire Barrier Duct Wrap 15A

UB1 AIR CONDITIONING UNIT INSTALLATION INSTRUCTIONS

Installation Operation & Maintenance Manual

All work shall comply with applicable codes and ordinances. Work shall comply with the BOCA National Plumbing Code, latest edition.

ASME Packaged Indirect Fired Water Heater

NCMA TEK CONCRETE MASONRY FOUNDATION WALL DETAILS. TEK 5-3A Details (2003)

SECTION AIR CONDITIONING UNIT

SAMPLE TEST QUESTIONS STEAMFITTER/PIPEFITTER - ITA WEBSITE

EcoTouch Insulation with PureFiber Technology

Cooking at the Speed of light!

One Year Warranty. Stock U.S. # of Volts Weight CONN. Height Dia. Watts # GAL. Elements INS. Inches NATURAL GAS* Six Year Warranty

SECTION HANGERS AND SUPPORTS FOR HVAC PIPING AND EQUIPMENT

SECTION CEMENT-MORTAR LINED AND COATED STEEL PIPE

Thermwire. Selection Guide. Freeze Protection Heating Cable. Thermwire -Wrap. Pre-Assembled. Thermwire-Comp. Thermwire-Melt.

STENCA PIPE. High quality pipe insulation.

Ventilation Solutions Kitchens. fantech

Asbestos Management POLICY

SECTION PRE-ENGINEERED BUILDING BLANKET INSULATION

The Silencer. Silencer Outdoor Air Blower, The Name That Says It All. Quality Product. Call for more information

SECTION GROUND WATER STORAGE TANKS

RESIDENTIAL PLUMBING ALTERATIONS PERMIT REQUIREMENTS

Acumen Enterprises, Inc.

first look at GigaCrete s revolutionary new New Construction GigaHouse GigaHouse Utilizing GigaPanel

AKRAPOVIC SLIP-ON EXHAUST SYSTEM for the HONDA CB1000R

Heating, Ventilation & Air Conditioning


1.2 Refrigerant Equipment. General

Air Conditioner Duct Construction & Repair

SWIMMING POOL AIR-HANDLING UNITS KU-DB Series

Commercial Gas Water Heater

Noise Control Solutions For Standby Power Generators

Build Green Schools. Click on this link for more information.

DIVISION 23 HEATING, COOLING, AIR CONDITIONING AND VENTILATION

Basics of HVAC Cleaning

MTA UNIVERSAL STATION PEDESTRIAN BRIDGE Los Angeles, CA. Project Manual and Specification 100% PE SUBMITTAL TABLE OF CONTENTS

M7RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. High Efficiency / Direct Vent Condensing Downflow Gas Furnace

October 5, 2015 Dear Client,

Keggomax CM Reflux Still

Gas Unit Heaters Duct Furnaces Horizontal - 60 HZ Form No. LF (10/2011) LF24 Standard

NAVIEN AMERICA INC FITCH AVENUE

G26 Corp L11 Revised LENNOXOEMPARTS.COM. Service Literature G26 SERIES UNITS

Saf-T Vent EZ Seal 3" and 4" (75mm and 100mm) Diameter Special Gas Vent (Type BH Class I/II) & Gas Vent Connector

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS

James M. Pleasants Company

BPI Air Conditioning & Heat Pump Professional Training Sample Slides ( ) Agenda

Pipe and Equipment Insulations. Zeston. PVC Insulated Fitting Covers Installation Instructions for Hot, Cold and USDA Piping Systems

foot skylight) is enough to knock a worker off their feet. A 10 mph wind gust on a 5 x 6 skylight develops a wind force of 270 lbs.

A Code Review for Emergency Generators and Indoor Use of Portable Generators

Butt Fusion Welding of HDPE Pipes Work Procedure

Element D Services Plumbing

Zero peel strength of acrylic pressure sensitive adhesive is at about 45 C (-50 F).

Installation, operation and maintenance manual TX 35A

Refrigeration Installation 101

SECTION 5 COMMERCIAL REFRIGERATION UNIT 22 CONDENSERS

DRAFT HOOD OUTLET GS6-30-YORT NG Select - Tall - C3 Technology 28 FIRST HOUR RATING BTU INPUT PER HOUR

SECTION MORTUARY REFRIGERATORS

Town House Center Highway North Huntingdon, PA 15642

COLD Heat Fire

All work must conform to the National Electric Code, latest edition, and all other applicable codes and regulations.

CHIMNEYS AND FIREPLACES

Installation Instructions

RPV - RP - RA air handling units

Building Envelope Design by Roxul (BEDR ) FireWall and Roxul Plus MB. Fire Rated Board Insulation for Pre-Engineered Metal Buildings

FOUNDATION INSULATING SYSTEM, INCLUDING WATERPROOFING AND DAMP PROOFING

ROOF TOP MOUNTED Air Handler Specification

Barewood Octagon and Elongated Windows Installation Instructions

Pipe threads for tubes and fittings where pressure-tight joints are not made on the threads. (requires PTFE sealing tape or liquid sealant).

Eurovacuum EV Series. Single Stage Oil Sealed Rotary Vane Pump

SUZUKI GSX-R 600 (2008)

Installation Manual CLIFC Fan & Coil Variable Speed

Transcription:

SUGGESTED SPECIFICATION EXHAUST SYSTEM SILENCER, FLEX CONNECTOR, INSULATION BLANKETS, WALL / ROOF THIMBLES 4121 N.W. 37 th Street, Lincoln, NE 68524 Telephone (402) 470-2627 Fax (404) 470-2410 www.gtexhaust.com

1. General Exhaust system shall consist of a silencer, flexible exhaust connector, elbows, piping, roof thimble, and mounting hardware. Furnish and install all required steel supports, hangers, clamps for mounting the silencer to an overhead structure. Complete system shall be wrapped in insulation blankets. 2. Exhaust Silencer Furnish an exhaust silencer for (Industrial, Residential, or Critical) type silencing. The silencer shall be sized to ensure that exhaust back-pressure does not exceed the maximum limitations specified by the engine manufacturer. The entire outer surface shall be (carbon steel, aluminized, or stainless steel) construction. The silencer shall be of side (or end) inlet design for horizontal mounting. Silencer shall have a drain valve in the silencer at the lowest point for condensation drain. The silencer shall be GT Exhaust Systems, Inc. Model or approved equivalent. 3. Exhaust Connector A flexible stainless steel exhaust connector shall be furnished between the engine and the silencer to minimize vibration as recommended by the engine manufacturer. Connector shall be of Type 321 stainless steel. The flex connector shall be GT Exhaust Systems, Inc. or approved equivalent. 4. Exhaust Insulation The interior exhaust piping, silencer, exhaust manifolds, and turbos shall be covered with insulation of a non-combustible type insulation material. Blanket temperature range shall be -67 F to 1200 F. Insulation material shall be high density 11 lbs./cu.ft. Type E fiberous glass insulation with standard thickness at 1.00. Blankets shall be totally encapsulated in 304 stainless steel mesh. Outer liner shall consist of a weather barrier silicone coated fiberglass cloth. All seams held together with 304 stainless steel hog ring staples. Tie down anchors, hooks, washers type 304 stainless steel. Lacing wire shall be type 304 stainless steel (16 GA.). No asbestos or asbestos-bearing products shall be used. The blankets shall be GT Exhaust Systems, Inc. or approved equivalent.

5. Wall / Roof Thimble The exhaust piping shall pass through the wall of the building by utilizing an insulated thimble constructed in conformance with NFPA 37 and 110. The thimble shall be of welded construction, consisting on an inner and outer sleeve separated by vented separators constructed to minimize the conduction of heat from the inner to the outer sleeve. The exhaust pipe shall fit within the inner sleeve and insulation material. Thimble insulation material shall be high density type E fibers, fibrous glass 11 lbs./cu.ft. The thimble shall extend at least nine inched above and nine inches below any portion of the structure. The thimble shall include a support collar and exterior flashing on the opening surface, welded to the outer sleeve of the thimble. Furnish a rain collar to clamp on the exhaust pipe and over the top of the thimble, to prevent the entrance of rain into the thimble. Include a screen to prevent entrance of birds and insects. Furnish an interior flashing piece to go on the inside of the structure. The rain collar and clamp shall be stainless steel. The thimble, support collar, and interior collars shall be of carbon steel with Galv-A-Grip protective coating. The thimbles shall be GT Exhaust Systems, Inc. or approved equivalent.

6. Application / Silencer Types Industrial Grade Series Model 201-2100 A rugged heavy-duty silencer for commercial or industrial areas where ambient noise levels are relatively high. Typical Attenuation: 14 to 20 db A Residential Grade Series Model 201-4100 Silencers designed for residential areas where ambient noise levels are relatively low. Typical Attenuation: 19 to 25 db A Critical Grade Series Model 201-5100 A critical level silencer for use where ambient noise levels are very low and a high degree of silencing is required. Typical Attenuation: 25 to 33 db A Super Critical Grade Series Model 201-6100 A critical level silencer for use where ambient noise levels are extremely low and a high degree of silencing is required. Features compressed acoustical fiberglass inserted between the double shell. Provides 300 to 400 (F) degree reduction in surface skin temperature Typical Attenuation: 32 to 40 db A Extreme Application Series Model 201-7100 An acute critical level silencer recommended for special applications when a single critical silencer is insufficient. It performs the work of two silencers in series. Features compressed acoustical fiberglass inserted between the double shell. Provides 300 to 400 (F) degree reduction in surface skin temperature Silencer incorporates both multi-chambered and annular passage flow design to provide maximum attenuation of all frequencies. Typical Attenuation: 45 to 52 db A Slim Line Critical Series Model 401-5100 of attenuation in a space saving, low profile size. Features compressed thermal acoustical insulation. Typical Attenuation: 27 to 32 db A

Slim Line Super Critical Series Model 401-6100 of attenuation in a space saving, low profile size. A critical level silencer for use where ambient noise levels are extremely low and a high degree of silencing is required. Features compressed thermal acoustical insulation. Typical Attenuation: 30 to 36 db A Slim Line Cool Critical Series Model 401-C-5100 of attenuation in a space saving, low profile size. Features compressed thermal acoustical insulation. The cool series provides additional internal insulation for lower surface temperatures. Typical Attenuation: 28 to 33 db A Slim Line Cool Super Critical Series Model 401-C-6100 of attenuation in a space saving, low profile size. A critical level silencer for use where ambient noise levels are extremely low and a high degree of silencing is required. Features compressed thermal acoustical insulation. The cool series provides additional internal insulation for lower surface temperatures. Typical Attenuation: 32 to 38 db A