Wireless 7 Day Programmable Room Thermostat



Similar documents
Drayton Digistat +2RF

Fused Spur Time Switch

OPERATING INSTRUCTIONS

CM921 - User Guide. Description. Features. 1 day Wireless Programmable Room Thermostat with LoT technology WHAT IS A PROGRAMMABLE ROOM THERMOSTAT?

Programmable Room Thermostat 7 Day (5-2 Day) Models: / Power Supply: Battery / Mains

Drayton Digistat +2RF/+3RF

User Manual THR840DUK Digital Thermostat

CM927 - User Guide. Description. Features. 7 day Wireless Programmable Room Thermostat with LoT Technology WHAT IS A PROGRAMMABLE ROOM THERMOSTAT?

TRANSMITTER RECEIVER THESE INSTRUCTIONS APPLY IN THE UK ONLY THESE INSTRUCTIONS ARE TO BE LEFT WITH THE USER OR AT THE APPLIANCE. Digistat Optimiser

2 Wire Electronic Time Delay Switch. 2 Wire Slave Switch. 3 Wire Electronic Time Delay Switch

MAKING MODERN LIVING POSSIBLE. Electronic 7 Day Programmable Room Thermostat TP7000 Range. User Guide. Danfoss Heating

5W LED Energy Saver PIR Bulkhead

Installation & User Instructions

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems

AN500T, AN1000, AN1000T, AN1500, AN1500T AN2000, AN2000T

TP5000 Si Range Electronic 5/2 day programmable room thermostat Mains, Battery and RF versions Installation and User Instructions

COMPUTHERM Q7 Programmable, digital room thermostat. Operating Instructions

Installation Guide for Hive Active Heating

Alpha Climatic Programmable Modulating Boiler Energy Manager. Installation and User Instructions

MAKING MODERN LIVING POSSIBLE. living connect. Installation and User Guide. Danfoss heating

SET1E. Installation & User Instructions. Electronic timeswitch for heating & hot water. Certification Mark

ecomax Instructions for use Wall hung room sealed fan assisted condensing boilers For the user

Operating Instructions DT, PRT, PRT/HW PRT-R, PRT-R2

Sensi TM. Wi-Fi Programmable Thermostat MANUAL OPERATION. Version: March Emerson Electric Co. All rights reserved.

Owner s Guide Guide du propriétaire Guía para el usuario TH115-AF-GB-10. Programmable thermostat Thermostat programmable Termostato programable

MAKING MODERN LIVING POSSIBLE. living connect. Installation and User Guide. Danfoss Heating Solutions

CM702 PROGRAMMABLE THERMOSTAT FEATURES PRODUCT SPECIFICATION SHEET

EK908FHL - Thermostat for floor heating

Portable Air Conditioner

Wireless Thermostats 230v and Battery Operated Instruction Manual

LUCCI AIRFUSION QUEST II CEILING FAN

ELECTRONIC THERMOSTAT AND THERMOMETER With SPEED CONTROL

its ELECTRIC POSITION for electric heat, or set the units fan control appropriately to ELECTRIC or another appropriate setting.

ELECTRIC POSITION for electric heat, then confirm with Fan Test below.

SIBIR MANUAL V110 KE. English page 5 RKE - 1D

HEAT PUMP PROGRAMMABLE THERMOSTAT

MOTION SENSOR PIR LIGHT SWITCH INSTALLATION & OPERATING. Cat No. ZV810 INSTRUCTIONS

User's Instructions. Alpha HE CB25/33 and HE SY25

IMPORTANT SAFETY INSTRUCTIONS WARNING READ AND SAVE THESE OPERATING AND SAFETY INSTRUCTIONS BEFORE USING THIS HEATER.

CR Band Auto Set Dual Alarm Clock Radio ROBERTS. Sound for Generations. Please read this manual before use

Rain+Birdt. Simple To Set Timer (SST) Setup & Operation Instructions. English RAIN BIRD ( ) or visit

1F /1/1 Day Programmable. 1F Thermostat Thermostat Configuration Options Heat Pump. Maximum Stages Heat/Cool 2/1

Baxi Platinum Combi HE Range. User s Operating Instructions & Important Warranty Information. Gas Fired Wall Mounted Condensing Combination Boiler

BARDIC. 4 & 8 Zone Fire Panels Zircon range. Data, installation, operation and maintenance. by Honeywell

EBDSPIR-PRM, EBDSPIR-PRM-IP

Baxi Combi 130 HE. User s Operating Instructions. Gas Fired Wall Mounted Condensing Combination Boiler

Wireless Indoor/ Outdoor Thermometer

USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102

Install Guide CT100. Caution. Caution ENGLISH. disconnect the power supply before beginning work.

ENGLISH INSTRUCTION & INSTALLATION MANUAL DUCTLESS MINI SPLIT AIR CONDITIONING SYSTEMS

USER MANUAL WARNING! CONTENTS MODEL 1 SPECIFICATIONS READ ALL INSTRUCTIONS BEFORE PROCEEDING. Non-Programmable Single Stage Heat/Cool Thermostat

GB/DAS User Instruction

Install Guide 3M-50. Caution. Caution

TABLE 1: Wiring Terminals. Connect to... 1C 1H 2C 2H 1H1C 2H1C 2H2C 3H2C

Radio Thermostat Clock Part Number: Installation & User Instructions. Suitable for all Ferroli Combination Boilers

Your Simple Guide to Battery. Replacement. Customer Care:

USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR

Table of Contents. 1 - Specifications Installation Wiring User controls...7

SET3M. electro-mechanical 24 programmer for heating & hot water. Installation & User Instructions

Contact Details. Please note that some of the contact details on this PDF document may not be current.

User Operating Instructions Horstmann 425 Coronet Electro-mechanical Timeswitch

Wireless Home Security Alarm System AM 500

60W PIR BULKHEAD LIGHT SLB88-Black/SLW89-White INSTALLATION & OPERATING INSTRUCTIONS

Install Guide CT101. Caution. Caution

INFRARED QUARTZ WALL HEATER

Installer guide. Release 2.2

Table of Contents. Introduction. Radio Frequency Control. Initial setup Setting the time. Setting the temperature

TYXIA. * _Rev.1* Installation and User Guide. Wireless receiver. TYXIA RF channel

Power Socket (2 Gang)

FAQs. Conserve package. Gateway... 2 Range Extender... 3 Smart Plug... 3 Thermostat... 4 Website... 7 App and Mobile Devices... 7

PSPA711a. LUXPRO PSPA711a INSTALLATION AND OPERATING INSTRUCTIONS. Mt. Laurel, New Jersey 08054, USA

HERZ-Thermal Actuators

THERMONET UNDERFLOOR HEATING STANDARD THERMOSTAT KIT STOCK CODE 5260

Operation Guide 3M-22

SAVE THIS MANUAL FOR FUTURE REFERENCE

BEDIENUNGSANLEITUNG Tieftemperaturheizkörper. MANUAL Low temperature radiator. NOTICE D UTILISATION E2 Radiateur basse température

CT3200 Programmable Thermostat

Installation Guide. VisionPRO. TH8000 Series. Need Help? This manual covers the following models. System Types

How To Control A Thermostat

User Guide and Important Warranty Information. Suprima 30L - 100L. Wall Mounted Fan Assisted Balanced Flue Gas Boiler

VIESMANN. Installation and service instructions VITOTROL 100. for contractors

INSTALLATION & SERVICE MANUAL. Display Panel

SP1790JK 900MHz Wireless Indoor/Outdoor Speakers. User Manual INTRODUCTION FEATURES IMPORTANT SAFETY INFORMATION

Baxi Combi 80e & 105e

T0118 T2118 T3118. Instruction Manual

FIREDEX Conventional Fire Panels

Short Range Wireless Switch System Handheld 8 Installation and Operations Guide

=============================== WARNING

DC1100 & 1400 Energy Controllers. Satchwell DC1100 & DC1400 for energy-efficient temperature control in smaller buildings.

SHOWER WATER HEATER MODEL BS 35 / 45 / 60 BS 35 E / 45 E / 60 E OPERATION AND INSTALLATION INSTRUCTIONS

DUAL SENSING DIGITAL THERMOSTAT PRODUCT INSTRUCTIONS. Construction Automotive Industry

TC-9102 Series Surface Mount Temperature Controllers

IN-OUT Thermometer with Cable Free Sensor and Clock

HMI display Installation Guide

Contact Details. Please note that some of the contact details on this PDF document may not be current.

Triac Printed Circuit Board Replacement

O. Gas boiler. Gaz 6000 W WBN H-E-N/L-S2400. Operating instructions for the end customer (2014/07) en

INSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930

Digistat RF Troubleshooting Procedure

Transcription:

Wireless 7 Day Programmable Room Thermostat Cat. No. TRT037 Transmitter Receiver Operating & Installation Instructions

What is a programmable room thermostat? an explanation for householders A programmable room thermostat is both a programmer and a room thermostat. A programmer allows you to set On and Off time periods to suit your own lifestyle. A room thermostat works by sensing the air temperature, switching on the heating when the air temperature falls below the thermostat setting, and switching it off once this set temperature has been reached. So, a programmable room thermostat lets you choose what times you want the heating to be on, and what temperature it should reach while it is on. It will allow you to select different temperatures in your home at different times of the day (and days of the week) to meet your particular needs. Turning a programmable room thermostat to a higher setting will not make the room heat up any faster. How quickly the room heats up depends on the design of the heating system, for example, the size of boiler and radiators. Neither does the setting affect how quickly the room cools down. Turning a programmable room thermostat to a lower setting will result in the room being controlled at a lower temperature, and saves energy. The way to set and use your programmable room thermostat is to find the lowest temperature settings that you are comfortable with at the different times you have chosen, and then leave it alone to do its job. The best way to do this is to set low temperatures first, say 18 C, and then turn them up by one degree each day until you are comfortable with the temperatures. You won t have to adjust the thermostat further. Any adjustments above these settings will waste energy and cost you more money. If your heating system is a boiler with radiators, there will usually be only one programmable room thermostat to control the whole house. But you can have different temperatures in individual rooms by installing thermostatic radiator valves (TRVs) on individual radiators. If you don t have TRVs, you should choose a temperature that is reasonable for the whole house. If you do have TRVs, you can choose a slightly higher setting to make sure that even the coldest room is comfortable, then prevent any overheating in other rooms by adjusting the TRVs. The time on the programmer must be correct. Some types have to be adjusted in spring and autumn at the changes between Greenwich Mean Time and British Summer Time. You may be able to temporarily adjust the heating programme, for example, Override, Advance or Boost. These are explained in the manufacturer s instructions. Programmable room thermostats need a free flow of air to sense the temperature, so they must not be covered by curtains or blocked by furniture. Nearby electric fires, televisions, wall or table lamps may prevent the thermostat from working properly.

1. Introduction TRT products are a cost effective comprehensive range of thermostats and controllers designed for internal use only. The TRT037 is a battery powered wireless electronic programmable room thermostat, with 6 different temperature periods per day, automatic summer/winter time changeover, 5 day plus 2 or individual (7) day programming, and a frost mode. There is also the option of optimum start and adjustable span, from 1ºC to 0.5ºC. The TRT037 comes in two parts a thermostat/ transmitter which is battery powered and totally wire-free as well as a receiver which connects into the heating system. This eases the installation in two ways there is no need to bury cable runs to the thermostat/ transmitter and the receiver can be mounted close to the boiler and other system components. The two parts are designed to be surface mounted on their supplied wall plates. The electrical supply must be isolated before attempting to install the receiver unit. TRT037 Wireless Programmable Room Thermostat/Transmitter Day of week Flashing when frost protection is on Fig. 1 Time of day (programme time during setting) Shows when heat is demanded Temperature override Room temperature display (set temperature displayed flashing during setting) Flashing symbol, battery change required Selects current set temperature and changes date, time and temperature Operates frost protection TRT037 Wireless Programmable Room Thermostat/Transmitter Button and screen illuminate when pressed and for 5 seconds after release Initiates programme setting sequence and in conjunction with the select button initiates time and date setting sequence Fig. 1a AM PM Border illuminates when +/- buttons are pressed and for 5 seconds after release AM PM S ET ROOM TEMP SET ROOM TEMP Selects time, temperature or date to be changed and is used with button to enable communication between the transmitter and receiver Reset button set reset select set reset select Programme access flap TRT037 Receiver Front View Learn/manual light Learn button enabling communication between the transmitter and receiver also controlling output in manual Fig. 2 Optimum start jumper Fig. 3 Span jumper A/M Learn TRT037 Transmitter Rear View Wall plate retaining screws (at bottom of TRT037) PROGRAM 5-2 7 SPAN 0.5 1.0 OST OFF ON Automatic/ Manual mode button Output on light Program jumper

Receiver Back Plate Removed Terminal for maintaining continuity of earth Fig. 4 Alternative fixing holes Fig. 5 Battery Holder Removal Lever battery holder outwards using a large flat bladed screwdriver (shown) or a large coin. Left hand side of TRT037 Fig. 6 COM NC NO N L Mount the wall plate in this configuration only Transmitter Back Plate Removed Mount the wall plate in this configuration only Battery holder Retaining tab Alternative fixing holes Retaining tab Alternative fixing holes Contents TRT037 thermostat TRT037 wall plate TRT037 instruction leaflet 4 x wall plugs 4 x screws 2. Siting 2 x AA batteries TRT037 receiver TRT037 receiver wall plate The TRT037 transmitter must be sited where it would not be influenced by heat sources, for example, above a radiator or television or refrigerator/freezer, or in direct sunlight or subject to draughts. The product requires air circulation, so do not position above or below shelving or other wall mounted obstacles. It should be mounted approximately 1.5m above floor level. The TRT037 receiver should be mounted close to the items it will be controlling i.e. boiler, control valves and pump. It should be mounted in a position where its control buttons and indicator lights can be easily accessed. 3. Installation Product should be installed by a qualified installer to current installation standards. If in any doubt contact the Timeguard Helpline 020 8450 0515. The TRT037 transmitter and receiver are designed to be surface mounted on their supplied wall plates. Always isolate the mains supply before removing the receiver from its wall plate. Read these instructions in conjunction with boiler instructions Transmitter Lever the battery holder out using a large flat blade screwdriver or large coin (see Fig. 6) and then pull out fully. Insert the 2 x AA alkaline batteries supplied into the battery holder maintaining the correct polarity as shown in the base of the battery holder. Push the battery holder back into place until it clicks shut. Remove wall plate from unit, by undoing retaining screws (see Fig. 5), and pivoting the bottom of the wall plate outwards. The TRT037 transmitter can then be lifted off. Fix wall plate securely to the wall, using screws (and wall plugs if necessary) provided. The screws which secure the TRT037 transmitter to the wall plate should point downwards. To reinstall the unit on the wall plate first ensure the wall plate retaining screws are loosened enough to clear the TRT037 transmitter body then engage the top of the TRT037 transmitter onto the wall plate retaining tabs (see Fig. 5), and push firmly downwards and then inwards. Once in place, secure with the retaining screws. Receiver Isolate 230VAC mains supply. Incoming and outgoing wires should be 1.5 sq mm. Remove wall plate from unit, by undoing retaining screws (see Fig. 4), and pivoting the bottom of the wall plate outwards. The TRT037 receiver can then be lifted off. Thread the incoming wires through the hole in the wall plate, and fix wall plate securely to the wall, using screws (and wall plugs if necessary) provided. The screws which secure the TRT037 receiver to the wall plate should point downwards. Allow sufficient excess cable to wire up the unit, but not too much to make it difficult to close the unit onto the wall plate. Connect the conductors to the relevant terminals, according to the wiring diagram below (Fig. 7). Ensure that the curved brass washers grip the conductors.

Receiver Wiring Diagram Fig. 7 COM NC NO N L Connections to boiler Check boiler instructions before connecting This unit is double insulated, and hence does not need connection to the earth. If earth continuity is required, please use the earth terminal on the wall plate, (see Fig. 4). To reinstall the unit on the wall plate first ensure the wall plate retaining screws are loosened enough to clear the TRT037 receiver body then engage the top of the TRT037 receiver onto the wall plate retaining tabs (see Fig. 4), and push firmly downwards and then inwards. There will be some resistance from the terminals. Once in place, secure with the retaining screws. Finally check that the system wiring is complete and correct. N L 4. Operation Initially it is important to get the two parts (transmitter and receiver) talking to each other. This is best carried out by two people, one at each of the separate locations. Press reset on the transmitter and at the receiver connect the mains supply to the unit. Both indicator lights (learn/ manual and output on the receiver) will come on for around 3 seconds and then go out. Press and hold the learn button on the receiver for around 10 seconds until the blue learn/manual light starts flashing. At the transmitter press and hold the select button for 1 second, keeping it held down, press and hold the button so they are both held down together. Hold them both down until the flashing blue learn/ manual light on the receiver goes out. The transmitter and receiver are now communicating. This can be confirmed by carrying out the following:- at the transmitter press the + button until the set temperature (identified by momentarily pressing the + or - button) is higher than the room temperature (normally displayed). After a short delay the output on light on the receiver comes on. Now press the - button at the transmitter until the set temperature is lower than the room temperature and after a short delay the output light will turn off. This proves the communication is fully functional. There is a manual facility available at the receiver. If the auto/manual (A/M) button is pressed the blue learn/manual light will come on indicating the receiver is in manual mode. The receiver output can now be turned on and off using the learn button. Programming Decide whether weekday/weekend (5 2) or individual (7) day programming is required and move the appropriate jumper on the rear of the TRT037 transmitter. The temperature span (difference between on and off temperatures) can be adjusted between 1ºC and 0.5ºC using a jumper found on the rear of the unit. Optimum start (switching on earlier on colder mornings) can also be turned on or off using a jumper on the rear of the unit. It is important to make these decisions first, as after any change of jumper position, reset needs to be pressed, which will return the unit to default time and programme. Pressing any button illuminates the screen automatically. During time/date and programme setting if a button is not pressed within 15 seconds the display will revert to the start of the sequence. Setting date and time of day Open programme access flap and press reset, using a pen or similar object. All of the screen segments will show briefly, and then the current room temperature will be displayed. To programme the date and time of day, open programme access flap, and simultaneously press and hold both the select and set buttons for 3 seconds. The year will flash. Use the + and - button to set the correct year. Press select to move on to programming the month (shown to the left), and then again to programme the day. Press select again to programme the hours (am/pm), and again to programme the minutes (each time using the +/- button to make the change). Press set to return to operating mode. If at any time a button is not pressed for 15 seconds, the unit will return to operating mode. Programming temperature periods for 7 days option Notes 1) There are no off periods with this controller. The programming sequence is:- Start time, temperature, second start time, second temperature and so on. Setting temperature to 10ºC is as close to off as can be achieved (and for most situations will be off unless the weather is very cold). 2) If you do not want a higher temperature period in the middle of the day adjust the temperature for this period downward to match those of the proceeding and subsequent period temperatures.

3) The TRT037 comes with a factory installed (default) programme for both 5 2 and 7 day options which you use or modify as you wish. Just pressing the reset button brings this programme into operation. The default programme for every day is as follows:- 6:00 AM 21ºC 8:00 AM 17ºC 12:00 PM 21ºC 2:00 PM 17ºC 4:00 PM 21ºC 10:00 PM 17ºC For both 5 2 and 7 day options. To programme the temperature periods, press the set button. Mon will flash. To programme Mondays time/temperature periods press select button. Alternatively use the + and - buttons to change the day, and then select to continue. The time will then flash. This is the start time for the first period. Press + or - to set the hour for the start time for period 1. Press select to move to the minutes. Use the + and - to set the minutes. Press select to set the temperature for this period. Use the + or - keys to set the desired temperature. Press select again to programme the next time period. There are 6 time periods per day. Once the 6 periods for Monday are programmed, Press set button, and Monday will start to flash. Use the + and - button to change the day to Tuesday, and then use select to program Tuesdays time periods and temperatures. For 7 day programming, this will need to be done for all 7 days. If set is pressed twice, the unit will return to operating mode. Omitting Days Omitting a day can be achieved by selecting 10ºC for every time period for that day (all times and temperatures must be entered). The heating will not turn on unless the room temperature falls below 10ºC (50ºF). Programming temperature periods for 5 2 days option For 5 2 day mode, time periods and temperatures will need to be programmed for M F and then for S S. i.e.: only 2 sets of times need to be programmed, not 7 (individual) sets of times. Temperature override In operating mode, the temperature set for the current period can be overridden. To adjust the set temperature, press the + or - button once. The screen will illuminate blue while button is pressed. Use + and - buttons to set desired temperature. If the + or - button is held down, the display will advance rapidly. Once the desired temperature is set, the unit should revert to displaying the current room temperature 5 seconds after the last button press. The illumination will also turn off after 5 seconds. In manual mode, there will be a hand symbol displayed on the screen. The new temperature will remain valid until the next programmed period starts. A burner symbol is displayed when temperature is below desired value, indicating that the thermostat is calling for heat from the boiler. Review set temperature The set temperature can be reviewed at any time, by a single press of the + or - button. 5 seconds after this single button push, the unit will show the current room temperature, and the screen illumination will turn off. Frost protection Frost protection reduces the set temperature to 5ºC. Frost protection is activated by holding down the frost protection button for 3 seconds. When in frost mode, the frost symbol will flash on the display. The set temperature buttons remain non-functional during frost mode. The unit will remain in frost mode until the frost button is held down for a further 3 seconds. Battery replacement When the battery needs replacing, a battery symbol will flash on the display. Sleep mode The unit can be put into sleep mode by simultaneously holding down the + and - buttons for 3 seconds. Pressing any button will exit sleep mode. In sleep mode, all outputs are suspended and the screen is blank (useful for longer periods when the house is unoccupied and frost protection is not required). To clean use a dry cloth only. Do not use any liquid cleaners. 5. Specifications Current rating: 3 (1) A Voltage: 230V, 50Hz Switch type: Single pole, change-over (SPCO) Volt Free Contact Operating temperature range: 0ºC to 50ºC Set temperature range: 10ºC to 35ºC adjustable in 0.5ºC steps Complies with: BS EN 60730 Span: 1ºC or 0.5ºC Micro disconnection: Type 1.B control action Batteries: 2 x AA alkaline

For assistance with the product please contact:- HELPLINE 020-8450-0515 or email helpline@timeguard.com 3 Year Guarantee In the unlikely event of this product failing due to defective material or manufacture within 3 years of the first date of purchase, please return it to your supplier in the first year for replacement free of charge. For years 2 and 3 or difficulty in the first year, please telephone the helpline 020 8450 0515. Note: a proof of purchase is required in all cases. For all eligible replacements (where agreed by Timeguard Ltd) the customer is responsible for all shipping/postage charges for sending replacements outside the UK. All shipping costs are to be paid in advance before a replacement is sent. For a product brochure please contact: Timeguard Ltd. Victory Park, 400 Edgware Road, London NW2 6ND Tel: 020-8452-1112 or email csc@timeguard.com A Group company 67-058-328 (Iss.2)