Mecc Alte 400Hz In Depth



Similar documents
World-class Synchronous Alternators

PM734F - Technical Data Sheet Winding 28

S Y N C H R O N O U S G E N E R A T O R S

PI734D - Technical Data Sheet

PI734B - Technical Data Sheet

HCM434F - Winding 311 APPROVED DOCUMENT. Technical Data Sheet

Generators TEM. for small hydroelectric power stations. Electric Machines

PI044E - Winding 311 APPROVED DOCUMENT. Technical Data Sheet

PI144K - Winding 311 APPROVED DOCUMENT. Technical Data Sheet. Generator Solutions AS

A S Y N C H R O N O U S M O T O R S

UCI274C - Technical Data Sheet

UCI274H - Technical Data Sheet

DLW 8. POWER RATING 1500 rpm/50 Hz 1800 rpm/60 Hz Prime 7.5 kva, 6 kw 9.1 kva, 7.3 kw Standby 8.5 kva, 6.8 kw 10.1 kva, 8.1 kw

32:(5#5$7,1* 4833#USP283#+] 4;33#USP293#+] 3ULPH 113 kva, 90 kw 124 kva, 99 kw 6WDQGE\ 114 kva, 91 kw 125 kva, 100 kw

32:(5#5$7,1* 4833#USP283#+] 4;33#USP293#+] 3ULPH 10.4 kva, 8.3 kw 12.9 kva, 10.3 kw 6WDQGE\ 11.3 kva, 9 kw 14.4 kva, 11.5 kw

BCI184E - Technical Data Sheet

3790 en / d. Alternators LSA Pole. Electrical and mechanical data

MOLECULAR DRAG PUMPS MDP SERIES

REVIEWED BY CAPITAL PROJECTS MANAGER (DAN REDDY) GENERAL MANAGER EQUIPMENT ENGINEERING & ASSET MANAGEMENT (HAMILTON NXUMALO)

Turbo generators Best quality for thermal power plants

HEAT MONITORING AND CONTROL INSTRUMENTS FOR TRANSFORMERS MB 103 TEMPERATURE CONTROL UNIT PT 100 TEMPERATURE SENSOR

Rules for Classification and Construction Additional Rules and Guidelines

Capacitor Voltage Transformer. Answers for energy.

New SACE Emax 2 for UL 1066 From Circuit Breaker to Power Manager

Brochure. Generators for wind power Proven generators reliable power

2CP. Twin-impeller pumps PERFORMANCE RANGE INSTALLATION AND USE APPLICATION LIMITS OPTIONALS AVAILABLE ON REQUEST CONSTRUCTION AND SAFETY STANDARDS

Type: DILM32 10(24V50HZ) Article No.:

Wound Rotor Induction Motors 4-12 poles, up to 8000 kw, HP

QPM3 Low pressure pump for circulation of oil in hydraulic and lubricating systems

DRAIN PUMPS. Synchronous Drain Pumps DPS / DPO

Energy Saving ECM Motors and Fans Ventilation Catalogue

Technical Description. Transistor D.C. Chopper Controller Type GS 24 S

Type: DILM115(RAC240) Article No.: Sales text Contactor,55kW/400V,AC operated. Ordering information

Type: DILM9 10(24VDC) Article No.:

Atlas Copco Generators

/ The allrounder with maximum yield. / WLAN interface / Smart Grid Ready

Power transformers. Special transformers Railway

Type: DILM50(230V50HZ,240V60HZ) Article No.:

AC Electric Motors best practice

Three-phase monitoring relay CM-PFE

Cable Solutions for Servo and Variable Frequency Drives (VFD)

How the efficiency of induction motor is measured?

EGSTON Standard E2xFxWx 12W

INDUSTRIAL DRIVE SYSTEMS ELEVATION LINE. Spring-applied single-disc/double-disc brake A A00

MUIRHEAD AEROSPACE Synchros

Cisco Unified IP Phone Power Injector

Brochure. Electric generators to power the world

TorqPlus TM Electric Valve Actuators and Controls

Low Voltage Transformers Sealed, General Purpose, Dry Type

Technical Concept. Filter Fan Unit COMPACT. Type COMPACT AC Type COMPACT EC

ELECTROPUTERE ROTATING ELECTRICAL MACHINES DIVISION

QUATTORDIO PLANTS. Quattordio 1 Quattordio 2

Principles of Adjustable Frequency Drives

SIRIUX. SINGLE AND DOUBLE HIGH EFFICIENCY CIRCULATORS Heating Air-conditioning OPERATING LIMITS APPLICATIONS. 28 m 3 /h* Heads up to: Flows up to:

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features

PRODUCTS DC MOTORS BLPM MOTORS AC MOTORS CONTROLLERS

Architectural Specifications MODEL HDXL Fairview Road, Unit #2, Barrie, Ontario L4N 8Z8

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Thermistor motor protection

TECHNICAL DATA 50HZ MPMC POWERTECH CORP. DIESEL GENERATING SET

TABLE OF CONTENTS INTRODUCTION...3 ADVANTAGES...5 OPERATION CHARACTERISTICS...6 EXCITATION TYPES...8 CONSTRUCTIVE COMPONENTS...9 ACCESSORIES...

Plug and Socket Devices CES 63 A Series 8579

Manual Motor Starter MS 116 up to 16 A Technical Data

Industrial Control Power Transformers

A.V.R. R250. Installation and maintenance R250 0V E+ E- VOLT STAB FREQ. & L.A.M. CONFIG. 50Hz. 47.5Hz. 57Hz LAM 1 13% 2 25% OFF LAM OFF 9

Online data sheet PET-1CB010N10SVMC PET PRESSURE SENSORS

ELEKTROTEHNI KO PODJETJE Leskoπkova cesta 12, 1000 Ljubljana, SLOVENIA

Analog signal converters CC-E I/I Current / current isolators

Single and three phase modular Automatic Transfer Switch from 40 to 160 A

Relative and absolute pressure switch type 529

Make the invisible visible! SENSORS WITH EXCELLENT BACKGROUND SUPPRESSION

1150 hp motor design, electromagnetic and thermal analysis

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages

Shaft grounding. Carbon brushes for shaft grounding are used in turbo-generators, in distinct AC- and DC motors and as a special application in Ships.

HC4/HC5/HC6/HC7 Aftermarket Parts List. Insist on Genuine

Product Guide Specification

Agilent 87421A/87422A Power Supply

Motor-CAD Software for Thermal Analysis of Electrical Motors - Links to Electromagnetic and Drive Simulation Models

TECHNICAL DATA 60HZ MPMC POWERTECH CORP. DIESEL GENERATING SET

CUSTOMS UNION. CUSTOMS UNION CERTIFICATE OF CONFORMANCE No. RU C-DE.ГБ05.В Series RU No

Pump Specifications 405 Series Commercial Drain Pump (High-Temp) 2 Solids handling

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

Vario-Series Accessories

Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.

"AC2EC" - Replacement made easy New EC motor design Compact and efficient

3) What is the difference between "Insulating", "Isolating", and "Shielded Winding" transformers?

Lab 8: DC generators: shunt, series, and compounded.

3753 en /b VE/B - VE/RG Va V riable speed drives

Annex-A TECHNICAL SPECIFICATION

Installation Contactors. Technical Catalogue. Type ESB. abb. ABB STOTZ-KONTAKT GmbH 1 2CDC C0201

DNVGL-CP-0393 Edition December 2015

Thermistor motor protection relays CM-MSS.22 and CM-MSS.23

Emergency stop As an emergency switching off/emergency stop device. Standards According to IEC/EN , VDE 0113 Part 1

2013 RESIBLOC transformers Product presentation. ABB Group October 2, 2013 Slide 1

*ADVANCED ELECTRIC GENERATOR & CONTROL FOR HIGH SPEED MICRO/MINI TURBINE BASED POWER SYSTEMS

PMDD WIND TURBINE 1.5MW

Actuator-Sensor-Interface

STANDBY 800 ekw 1000kVA 60 Hz 1800rpm 480Volts

RM4TG20 three-phase network control relay RM4-T - range V

Transcription:

400Hz Alternators

Proven Capability High levels of performance, with the standard alternators filled with performance enhancing features. Supported through an experienced and computer assisted FEM design, professional team able to evaluate all tenders and ensure excep-tional support both pre and post order. Unique special machines to suit case specific applications are available, with a specific design to as sure the lowest possible losses that is so critical in 400Hz machines. We know that iron losses and shaft currents are a thought job at high frequency, and we select the lowest losses electrical steel on the market. Exceptional Excitation The MAUX (Mecc Alte AUXiliary Winding) is used throughout the range of alternators, and has been a proven standard for Mecc Alte in all market sectors. It is a brushless excitation system deriving power from a dedicated auxiliary winding within the main stator. This winding is protected by 4 layers of polyester in addition to the clear varnish and EG43 severe environment protection used in the most demanding applications. Fitted within the main stator, it minimizes overall dimensions of the alternator and ensures a compact machine. This system ensures a high level of motor start ability, and surpasses the mandatory requirements giving >300% forced current (short circuit maintenance) for 20 seconds 10 seconds more than the standards require. UVR6-H400B The UVR6-H400B regulator is an advanced compact electronic regulator used from Mecc Alte for 400 Hz machines. It is internally designed, as we know that this is the only viable route to get the best from our machines. This regulator is equipped with a low speed and overload protection with an adjustable intervention threshold, it has adjustable voltage stability and it offers the possibility for a remote voltage regulation with a 3-phase sensing capability. Construction Rigid steel frames (FeP12) Rotors are dynamically balanced with ½ key (ISO 8821), conforms to class G.2.5 (ISO 1940) Copper damping cage is standard from 45kVA, for superior transient load performances Bearings Sealed for life bearings. On customer request, we can select insulated bearing Radio Interference Suppression The standard generators comply with the specification VDE 0875, degree N and with the basic safety requirements of the European regulation on electromagnetic compatibility; by applying the EN 60034-1 and aviation rules, we comply with the above-mentioned regulation. Other standards can be achieved adding filter sets, supplied by Mecc Alte. 2

Insulation and Impregnation Insulation materials used provide a system insulated to Class H level. Superior processes are employed to add an EG43 compound after insulation over the main and exciter windings to give a very high standard of protection. Higher levels such as the black butadiene (rubberized) coating are also available. Reliability Standardized components are used with families of industrial machines to give very high degrees of interchangeability. Lower component count throughout the range, and also within individual machines, has focused efforts to enhance the reliability of the products. In testimony to this, the reliability prediction according to the military standard MIL-HDBK-217F, was a failure rate of 75,82 fpmh (failures per million hours), 13,189 hours mtbf (mean time between failures). Minimum Maintenance The design of the Mecc Alte 400Hz alternators are built with low maintenance in mind. Bearings have up to 40,000 hours life expectancy, and windings, including the auxiliary winding, have high degrees of protection. Where maintenance is necessary, access is very simple (ie no PMG (permanent magnet generator) to remove before replacing and exciter stator. In addition the commonality of parts improves component availability. Accessories A large number of accessories are available on request. Including: Space heaters Temperature detectors (thermistors or PT100), for windings and bearings Higher degrees of mechanical protection (IP23, IP45 or inlet air filters) Line drop compensator (LDC) Black butadiene winding protection Quality Assurance Products are built in accordance with ISO 9001, accredited by Det Norske Veritas; approvals by Canadian Standards Authority (CSA) and also Underwriters Laboratory (UL) for the insulation systems. Designs are executed according to the most common specifications such as CEI 2-3, IEC 34-1, EN 60034-1, VDE 0530, BS 4999-5000, CAN/CSA- C22.2 No.14-95 No.100-95, or aviation rules ISO 1540, BS 2G 219, EN2282, Mil STND 704F. Lamination design has been developed by finite element analysis. Compact Dimensions Comparing against the competition, the Mecc Alte 400Hz alternators are among the most com- - pact and light alternator packages available. This incredible fact considers machines are among the highest efficiency. This highlights the superior ability of Mecc Alte in the design and production of their alternators. 3

Power ratings 115/200-208V 400 Hz - 3 Ph. 40 ambient temperature HCO3-1S/14 3428 5,5 5 HCO3-2S/14 3428 7 6,5 HCO3-3S/14 3428 9 8,5 HCO3-2L/14 3428 11 10 HCO3-3L/14 3428 13 12 HCO32-1S/20 2400 45 40 HCO32-2S/20 2400 50 45 HCO32-2L/20 2400 60 55 HCO32-3L/20 2400 70 65 HCP34-1S/20 2400 75 70 HCP34-2S/20 2400 95 85 HCP34-3S/20 2400 125 115 HCP34-1L/20 2400 150 135 HCP34-1SN/24 2000 60 55 HCP34-2SN/24 2000 90 80 HCP34-2LN/24 2000 125 110 According BS 2G 219 - EN2292 - ISO 6858 - Mil Stnd 704F HCO38-1L/24 2000 150 135 HCO38-2L/24 2000 180 165 HCO38-3L/24 2000 200 180 According BS 2G 219 - EN2292 - ISO 6858 - Mil Stnd 704F are available on direct request. 4

Mecc Alte SpA Via Roma, n 20-36051 Creazzo Vicenza - ITALY T: +39 0444 396111 F: +39 0444 396166 E: mecc-alte-spa@meccalte.it sat2@meccalte.it France Mecc Alte International S.A. Z.E.La Gagnerie 16330 ST.Amant De Boixe T: 0545/397562 F: 0545/398820 E: mecc.alte@meccalte.fr philippe.denis@meccalte.fr United Kingdom Mecc Alte U.K. LTD 6 Lands End Way Oakham Rutland T: 1572/771160 F: 1572/771161 E: gen@meccalte.co.uk rod.marshall@meccalte.co.uk Germany Mecc Alte Generatoren GmbH Ensener Weg 21 D-51149 Köln T: 02203/503810 F: 02203/503796 E: info@meccalte.de service@meccalte.de China Mecc Alte Alternator Haimen LTD 755 Nanhai East Rd Jiangsu HEDZ 226100 PRC T: +86 0513 82325708 F: +86 0513 82325768 E: sales@meccalte.cn Far East Mecc Alte (F.E.) PTE LTD 19 Kian Teck Drive Singapore 628836 T: +65 62 657122 F: +65 62 653991 E: enquiry@meccalte.com.sg enquiry@meccalte.com.sg Spain Mecc Alte España S.A. C/ Rio Taibilla, 2 Polig. Ind. Los Valeros 03178 Benijofar (Alicante) T: 096/6702152 F: 096/6700103 E: gerencia@meccalte.es serviciotecnico@meccalte.es U.S.A. and Canada Mecc Alte Inc. 1229 Adam Drive McHenry IL, 60051 (USA T: 815 344 0530 F: 815 344 0535 E: sales@meccalte.us sales@meccalte.us Australia Mecc Alte Alternators PTY LTD 10 Duncan Road, PO Box 1046 Dry Creek, 5094, South Australia T: +61 (0)8 8349 8422 F: +61 (0)8 8349 8455 E: sales@meccalte.com.au India Mecc Alte India PVT LTD Plot N.1 Sanaswadi-Talegaon Dhamdhere Road, Takura: Shirur - Pune 412208 T: +91 2137 619600 F: +91 2137 619699 E: sales@meccalte.in