Multi-Foil reflective insulation SPACE SAVING U-VALUE AS LOW AS 0.16W/m 2 K LIGHTWEIGHT EASY TO FIX



Similar documents
Multi-layer Insulation Blanket for Roofs

CERTIFICATE NAME OF PRODUCT MANUFACTURER PRODUCT DESCRIPTION CERTIFICATION PROCEDURE. No VTT C Date of issue , Updated July 1, 2011

Rockwool Flexi Insulation Application Guide

GUIDANCE SHEET FOR CONSERVATORIES, SUNROOMS AND EXTENSIONS TO DWELLINGS.

Section Timber Frame Walls. Single layer between studs. Single layer between studs with service void. Between studs with insulated lining

Timber Frame Walls Rethinking Construction

Including. Rubershield-Pro. Breather Membrane

The Pocket Guide To Insulation August 2013

Contents. APA Construction Details. Full fill cavity walls Partial fill cavity walls Solid externally insulated walls 26-37

Building Regulations for the Conservation of Fuel and Power

Rockwool Cladding Roll

Built-up roofing solutions with rigid insulation boards on concrete decks for new-build and refurbishment E-a5

Section 5.0. Basements. Wall insulated externally. Wall insulated internally. Ba02. Product: Polyfoam ECO Floorboard Ba01.

BER Assessors Dwellings Technical Bulletin

Section 2.4. Built-up Metal Roofs. Rail and bracket system. Standing seam system. Bu02. Product: Earthwool FactoryClad range Bu01

BUILDING CONTROL GUIDANCE SHEET USE OF BREATHABLE ROOFING FELTS.

Manual lifting and handling

Building Control Guidance Note

CHESTERFLEX ROOF WATERPROOFING MEMBRANES

The Kingspan Insulation Price List 1 st January 2013

ENVIRONMENTAL INFORMATION APR 1200 products are made from glass mineral wool, one of the most environmentally friendly insulants available.

INSULATED PITCHED ROOFING

FLAT ROOF INSULATION INSULATION ROOFING FLAT. Quick Guide. Quick Guide. Insulation. EcoTherm Insulation UK Sales Team. Insulation

FACTORS AFFECTING ENERGY CONSUMPTION OF BUILDINGS

Providing protection in construction

PB301 July Lightweight Building Solutions. Bushfire Protection.

AND MEMBRANES ROOFING UNDERLAYS.

TR21. I n s u l a t i o n. Low Energy Low Carbon Buildings

Introduction. 1. Heat Transfer. In Townsville s climate it is essential to choose building materials that perform well in our local conditions.

BLACK JACK ALL WEATHER ROOF COATING

Innovation #9/12. of all Formaldehyde for up to

FireWall. High performance fireresistant. FireWall.

British Gypsum Guide to Timber Frame Construction. March 1998

HEALTHY LIVING WITH WOOD FIBRE INSULATING MATERIALS

Rooflighting and Glazing

Asphalt Shingle Application Requirements

Guide to domestic building renovation. Telephone: Fax:

Ubiflex. Non-lead flashing system

Glass partitions SFB 3074

Composite Panel Firewall Systems

Energy Efficiency in Buildings

Mold Preventing I nterior System

Steel-framed Walls. Insulation

Roofers Guide to Underslating Membranes

SOUND INSULATION FOR EXTERIOR WALLS AND FACADE SYSTEMS

Knauf Aquapanel Interior. Tile Backing. Cement board for wet areas. Will not deteriorate in water. Easy to score and snap

Low Energy Low Carbon Buildings

C05. S03. P02 P08 FireWall. Including C05. S01. P02 Specialist partitions introduction

The Real Value of Space

fire separating walls #2

IES <Virtual Environment> Tutorial. Apache Sim (Version 6.0)

ROOFERS CHOICE BREATHER MEMBRANES FOR USE IN COLD NON-VENTILATED ROOFS

Innovation - High performance roof, wall and floor insulation board. delivering better performance

Thermal Performance of Steel Beam Junctions using Different Connection Methods

SANS FIRE PERFORMANCE SANS 428 ENERGY SAVER REFLECTIVE TIASA A MEMBER OF 2009/ / / /341

ANSI/ASHRAE Standard Building Thermal Envelope and Fabric Load Tests

Conservatory warm roof conversion system

Sun-Activ - reflective SBS membrane. Sun-Activ - White reflective bituminous waterproofing membrane for Cool Roof

European Organisation for Technical Approvals

Mineral fibreglass insulation

Module 3.7. Thermal bridging

TP10. Insulation RAFTER LEVEL INSULATION FOR TILED OR SLATED PITCHED WARM ROOF SPACES BBA BRITISH

Section 2.3. Flat Roofs. Warm deck single ply membrane. Warm deck single ply membrane. Warm deck built-up felt/ mastic asphalt. Protected membrane

INTERIOR WALLS AND BASEMENTS CHOOSING THE RIGHT MEMBRANE FOR INTERIOR WALLS. Multi-Layer Technology provides increased strength.

NRG 75 CRF NRG GREENBOARD WALL SYSTEM

CEILING SYSTEMS. CI/SfB (35) Xy April [Between us, ideas become reality.] ULTIMA CANOPY. Data sheet. Acoustic performance meets High Design

Sika Membran System For Sealing and Waterproofing Construction Gaps in Building Façades

Regulations Detail Sheet 1

TR31. I n s u l a t i o n. Low Energy Low Carbon Buildings

STENCA HT PIPE. Quality Insulation made of calcium silicate.

Rochdale Building Control Guide. Approved Document C. Site preparation and resistance to contaminants and moisture

Initial Type Testing Report

WATERPROOFING OF REINFORCED CONCRETE FLAT ROOF 12

ProRox Slabs (formerly known as RW slabs)

- Version 2 Total R-value calculations for typical building applications

Interior Walls below and above ground OLDROYD THE ULTIMATE WATERPROOF MEMBRANE SYSTEM

Low Energy Low Carbon Buildings

Conventions for U-value calculations

DELTA Premium Moisture Management Systems for Foundations.

STEEL BUILDINGS IN EUROPE. Single-Storey Steel Buildings Part 8: Building Envelope

STRUCTURAL CONCEPT FOR LIGHT GAUGE STEEL FRAME SYSTEM

Technology at its best. Benefits

Rev Code of Practice. SIP Technology.

Final inspections are completed by site visit only. Access to fenced yards shall be planned.

THE MINISTRY OF ENVIRONMENTAL PROTECTION, PHYSICAL PLANNING AND CONSTRUCTION

I n s u l a t i o n. Low Energy Low Carbon Buildings

PROVIDING PROTECTION IN CONSTRUCTION Technical guide: roofs.

What a good idea! Turn your conservatory into an all-year-round living space.

Data Sheet VITOSOL 100. Flat collectors for the utilisation of solar energy. Vitosol 100. Part nos. and prices: see price list

Cupa Natural Slate Roofing design and fixing guide

Residential Refurbishment. September ThermoShell Internal Wall Insulation System Design Guide

IEA SHC Task 47 Renovation of Non-Residential Buildings towards Sustainable Standards

Regulatory Services. Asbestos in the Home. What is asbestos?

!!!!!! !!! Decra Plus DPSW010 DPSTW011 DPSW012 DPSW013 DPSW014 DPSW015 DPSW016 DPSW020 DPSW021 DPSW024 DPSW030 DPSW031 DPSW035 DPSW030 DPSW031 DPSW035

Insulated Roof & Wall Panels. Product Data Sheet. Trapezoidal Insulated Roof Panels KS1000 RW

Twiga Insul. India's Leading Thermal and Acoustic Insulation. Insulating India


CITY OF WHITE BEAR LAKE BUILDING INSPECTION DEPARTMENT 4701 Highway 61 White Bear Lake, MN Fax: Re-Roofing: Asphalt Shingles

Annex of the certificate (Page 1/6) Accreditation Scope

Introduction & Principles Issued in support of Junction Details, Parts 1 to 5

Transcription:

Multi-Foil reflective insulation SPACE SAVING U-VALUE AS LOW AS 0.16W/m 2 K LIGHTWEIGHT EASY TO FIX

TECHNICAL CHARACTERISTICS Multi-Foil Reflective Insulation Xfoil Range of insulation is designed to achieve the required thermal insulation performances in your roof space, using reflective technology. Based on a Pitch roof application Xfoil can give you a *U-Value as low as 0.16W/m 2 K. The Xfoil Range seals your roof against climactic elements like wind and damp while at the same time retaining ventilation. Using reflective technology Xfoil is clean, does not cause allergies, does not cause dust and contains no toxic products. The Xfoil Range is constructed from numerous layers, depending on which Xfoil you purchase. Your product will be made up of Insulaid - a reactive thermal product which is one of the best on the market and uses high strength polyester, reinforced metallised polyester film and also polyester wadding. Xfoil offers you a sustainable product that insulates your roof and helps with acoustic performances. Example on the right shows Xfoil 21 being used in a barn conversion. The Xfoil Range Euroform offer 2 types of Xfoil to suit all roof applications to achieve the required insulation performances. Product Type Xfoil 21 Xfoil 25 Number of layers 7 11 *Thermal efficiency Equiv. 210mm Equiv. 240mm Glass Fibre Glass Fibre Surface area 15m 2 15m 2 Weight per roll 10kg 12kg Roll width 1.5mtr 1.5mtr Roll length 10mtr 10 mtr Expanded thickness 35mm 50mm Compressed thickness 2mm 3mm *Pitch Roof U-Value 0.18 W/m 2 K 0.16 W/m 2 K Example of Achievement (see calculation on the next page)

TECHNICAL CHARACTERISTICS How Does Xfoil 21 Perform? Please see our U-Value Calculation Element: Pitch roof, ceiling at rafter line - Uvalue Element 2 Internal Surface Emissivity: High External Surface Emissivity: High Building Use: BS5250 dry/moist occupancy Construction Thickness Thermal Thermal Bridge mm Conductivity Resistance (W/mK) (m 2 K/W) Outside surface resistance 0.040 Tiling including batten space 50.0 0.120 0.180 Sarking Felt 2.0 0.200 0.010 Xfoil 21 35.0 5.250 Gyproc Duplex Wallboard 12.5 0.070 Thistle Finish Plaster (Multi-Board) 2.0 0.200 0.010 Inside surface resistance 0.100 U-Value - 0.18 W/m 2 K. U-Value, Combined Method: 0.18 W/m 2 K (lower limit 5.660 m 2 K/W, upper limit 5.660 m 2 K/W, duf 0.000, dug 0.000) (Correction for mechanical fasteners, Delta Uf = 0.000 W/m 2 K) (Correction for air gaps, Delta Ug = 0.000 W/m 2 K) How Does Xfoil 25 Perform? Please see our U-Value Calculation Element: Pitch roof, ceiling at rafter line - Uvalue Element 1 Internal Surface Emissivity: High External Surface Emissivity: High Building Use: BS5250 dry/moist occupancy Construction Thickness Thermal Thermal Bridge mm Conductivity Resistance (W/mK) (m 2 K/W) Outside surface resistance 0.040 Tiling including batten space 50.0 0.120 0.180 Sarking Felt 2.0 0.200 0.010 Xfoil 25 50.0 6.000 Gyproc Duplex Wallboard 12.5 0.070 Thistle Finish Plaster (Multi-Board) 2.0 0.200 0.010 Inside surface resistance 0.100 U-Value - 0.16 W/m 2 K. U-Value, Combined Method: 0.16 W/m 2 K (lower limit 6.410 m 2 K/W, upper limit 6.410 m 2 K/W, duf 0.000, dug 0.000) (Correction for mechanical fasteners, Delta Uf = 0.000 W/m 2 K) (Correction for air gaps, Delta Ug = 0.000 W/m 2 K)

TYPICAL CONSTRUCTION ROOFING MEMBRANE REFLECTS EXTERNAL HEAT REFLECTS EXTERNAL COLD XFOIL XFOIL CROSS BATTEN PLASTERBOARD RETAINS HEAT LOSS

FAXBACK Tick the following boxes for more information and fax back to 01925 860066 or visit our website www.euroform.co.uk Versapanel Versafire Versaliner TM JPM Ufoil TM Xfoil TM Multi-Foil Versachimney TM Reflective Insulation Versalayer TM Versadorm TM & Canopies Versafloor TM EZ Wall TM External Cladding Specialist Fabrication Service Euroform Products Limited will not distribute to any other company any information given on this reply form. However, this information will be added to our Company database in order to process your request. We may contact you for further information regarding your enquiry. If you would like to be taken off our database at any time after this please let us know on 01925 860999 or email info@euroform.co.uk. COMPANY NAME POSITION ADDRESS POST CODE TELEPHONE FAX EMAIL The Heliport Lyncastle Road Off Barley Castle Lane Appleton Warrington WA4 4SN Tel: +44 (0) 1925 860999 Fax: +44 (0) 1925 860066 Email: info@euroform.co.uk www.euroform.co.uk Due to our policy of continuous development we reserve the right to change design and specifications without prior notice. Euroform Products Limited does not accept responsibility for any loss as a result of any company or person relying on material in this publication, or for any mistakes or misprints. Although every care is taken to ensure accuracy, this brochure is a general guide and specific technical advice is recommended before proceeding with any transaction. Specific fact sheets, or, technical information is available from Euroform technical department 01925 860999.Reproduction of any part of this publication in any manner is not permitted without prior written consent from Euroform Products Limited. 05/2006