Toroidal Conductivity Sensor



Similar documents
Sanitary and CIP Toroidal Sensor

Submersion/Insertion Toroidal Sensor

Submersion/Insertion Toroidal Sensor

ENDURANCE Conductivity Sensors

General Purpose ph/orp Sensors

ph Sensor Model 397 CAUTION SENSOR/PROCESS APPLICATION COMPATIBILITY WARNING ATEX DIRECTIVE Instruction Sheet PN 51A-397/rev.

Ozone Sensor. Model 499A OZ CAUTION CAUTION. Instruction Sheet PN 51A-499AOZ/rev.F January 2007

Dissolved Oxygen Sensors

PART 1 - INTRODUCTION...

For additional information, please visit our website at

Trace Dissolved Oxygen Sensor

General Purpose ph/orp Sensor

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES

Float and Thermostatic Traps Series H, C and X

Installation and Operating Instructions Installation Instructions for SS EPE-316L Series

FL ADJUSTABLE RIDER BACKREST MOUNTING HARDWARE KIT

ATL Fuel Level Sender Probes

Threaded Resistance Thermometers Model TR10-D, Miniature Design

Your safety and the safety of others are very important.

ATS Overhead Table Shelf System INSTRUCTION MANUAL

DiwiTherm, Resistance Thermometers Model TR75, with digital Display Battery or Solar Powered

The Unique Accelabar Flow Meter

SITRANS F flowmeters SITRANS F M

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter

Trunnion-Design Ball Valves

Digital inductive conductivity transmitter

SCION tc COIL OVER SUSPENSION Preparation

Important: Please read these instructions carefully and completely before starting the installation. TITAN Fuel Tanks

MVX-Series Diesel Engine Air Shut Down Valves

OEM Manual MODEL 2350 ELECTRONIC DUAL CYLINDER SCALE

DTM04 TANK MONITOR DTM08 TANK MONITOR Dtm12 TANK MONITOR. Installation and Operation Manual

SureSite Magnetic Liquid Level Indicator

XL PREMIUM OIL COOLER KIT

Quick Connect Boxes Inside Gloveboxes

SERIES ASM NEOPRENE/EPMD FLANGED SINGLE SPHERE CONNECTOR CONNECTORS. Pressures to 225 PSIG (15.51 barg) Temperatures to 230ºF (110ºC)

AMERBRITE UNDERWATER WHITE LED POOL LAMP

Micro Motion Model D and DL Coriolis Flow and Density Meters

INSTALLATION & OPERATING INSTRUCTIONS

Arecont Vision H.264 Color or Day/Night SurroundVideo Series Installation Manual

Tipping Bucket Rain Gauge Models 6011-A 6011-B

Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS

TB2CS Conductivity sensor 2-Electrode. Superior accuracy in low level conductivity measurement ranges

A99B Series Temperature Sensors

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

Volkswagen Jetta, Golf, GTI 1999, 2000 Brake System 47 Brakes - Hydraulic Components (Page GR-47)

Front axle components, overview

PSS10H/B PSS12H/A ILLUSTRATED PARTS LISTS

ball valves Flomite 71 Series 2-way Integral Panel Mount Ball Valves

POWERS Controls No. 4 Pneumatic Damper Actuator

Installation instruction CASAFLEX - Connecting piece DN 100

INSTALLATION INSTRUCTIONS Air Spring Kit Ford F250 Single Wheel 4WD Ford F350 Dually 4WD (2011 F350 Single Wheel 4WD use p/n 6113)

REPAIR AND MAINTENANCE MANUAL

DirectCommand Installation DirectCommand 3-Channel Spreader Kit

F-Series Camera Mounting Accessories

PowerFlex 700S and 700H Frame 12 DC Bus Connector Kit

Elo Touch Solutions Wall-mounting Kit for the 5501L IDS Touchmonitors

Replacement parts. WM97+ gas-fired water boiler Boiler Manual. OBTAIN PARTS ONLY THROUGH WEIL-McLAIN THE BOILER CONTAINS CERAMIC FIBER MATERIALS

HOME GYM. Model. Retain This Manual for Reference OWNER'S MANUAL.

Mini USB and USB 2.0-IP67 Connector System

INSTALLATION INSTRUCTIONS HUSTLER 4-BTV, 5-BTV TRAP VERTICAL WARNING INSTALLATION OF THIS PRODUCT NEAR POWER LINES IS DANGEROUS

Cylinder head gasket, replacement

ENGINE FUEL FUEL FILTER... FUEL HEATER... INJECTOR... SUPPLY PUMP... COMMON RAIL... FUEL PRESSURE LIMITTER...

Instructions Manual. Electromagnetic sensor Series FLOMID FX. instrumentation for fluids. R-MI-FlomidFX Rev.: 0 English version

AM/FM ANTENNA RELOCATION KIT

DETACHABLE WINDSHIELD AND DOCKING HARDWARE KIT

Flow Sensors. Convenient, Reliable and Economical Flow Measurement. THORNTON Leading Pure Water Analytics

IF IT FLOWS THE BOWIE PUMP CAN PUMP IT

Fisher 1052 Size 20 Diaphragm Rotary Actuator with F and G Mounting Adaptation

REV. REL 1302 WEST BEARDSLEY AVENUE P.O. BOX 1127 ELKHART IN (574) FAX (574) ELKHART BRASS MFG. CO., INC.

Depending on which elastic support you have you can secure the V2 power unit to the following seat bracket tubes: EXTERNAL DIAMETER 27.

STORAGE, INSTALLATION AND MAINTENANCE PROCEDURES

M113 VEHICLE FAMILY RUBBER TRACK INSTALLATION INSTRUCTIONS SOUCY TRACK SYSTEM 04-M113-1ENS (SPLIT IDLER) Litho d in Canada 1 04-M113-1ENS

DeZURIK 3-20" BAW AWWA BUTTERFLY VALVES WITH TRANSFER MOLDED SEAT


James M. Pleasants Company

Small Flat Panel Lift Arm FSA-1004 and KSA-1004

MVX-Series Diesel Engine Shut Down Valves (Cable Operated Closure/Integral Reset Lever Types)

STC 3S A Series Solenoid Valves

MAGTROL. ZS Series Load Cell. ZS Data Sheet. Features. Description

Fisher 249 Caged Displacer Sensors

5800 Temperature Sensor Cable Assembly

GATE VALVES ASAHI AV VALVES. Type P (Standard: Plug) Type S (Soft Seal) Contents. (1) Be sure to read the following warranty clauses of our product 1

Pressure monitoring equipment for oil-sf 6. bushings, type GOEK

BBWX1 Satellite Weather Receiver. Installation and Maintenance Guide

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

Givare NC-SRS 280 och 880

WAVELET WATER QUALITY MONITORING KIT

CRANE. Σελίδα 1 από 2. Dimensions and Weights. Weight (kg) Size

Installation Instructions Hustler 6-BTV Trap Vertical

These Installation Instructions are valid for antennas in the following version:

Fire Hydrant Troubleshooting

TITAN Fuel Tanks. INSTALLATION INSTRUCTIONS G e n e r a t i o n V

Original instructions Protective tube for Orion1B and Orion2 Orion WET-xxx and Orion WET-Kxxx

Two most common lock nut groups: 1-Prevailing Torque Type Lock Nuts:

Installation Instructions GOOSENECK MOUNTING KIT Chevrolet/GMC 1500/2500/3500 All except 4-door Crew-Cab

HG600/HG800. Hydro-Power Unit. Installation and Operation Guide

Cooktop Low-Profile Ventilation Hoods

INSTALLATION INSTRUCTIONS Air Spring Kit Ford F250/F-350 Single Wheel 2WD Ford F350 Dually 2WD IMPORTANT NOTES

3500/93 System Display

Transcription:

Instruction Sheet PN 51A-/rev.C June 2012 Toroidal Conductivity Sensor For additional information, please visit our website at www.emersonprocess.com/rosemountanalytical.com SPECIFICATIONS Wetted Materials: Teflon-lined carbon steel pipe, with carbon steel outer flanges. Option-21 has 316 SS outer flanges. Temperature and Pressure: Flange Option Temperature Pressure 150 lb -01 and -02 41 F(5 C) - 360 F (182 C) 125 psig (963 kpa abs) 300 lb -05 and -06 41 F(5 C) - 360 F (182 C) 250 psig (1825 kpa abs) Pressure (for CRN registration only): Flange Option Pressure (max) 150 lb -01 and -02, and -01-21 125 psig (963 kpa abs) 300 lb -05 (1 inch) 200 psig (1480 kpa) 300 lb -06 (2 inch) 250 psig (1825 kpa abs) Outside flanges: ANSI B16.5 raised face, threaded. INSTALLATION First, decide whether the initial calibration will be done in the shop before installing the sensor or in the process piping after installing the sensor. Refer to the Calibration section for information about in-shop and in-process calibrations. NOTE Install the sensor in a location where it will be completely filled with process liquid. A vertical pipe run with the flow from bottom to top is best. 1. Remove the grounding strap from the outer flanges. See Figure 1. Save the strap and all the hardware for reassembly. 2. Carefully remove the nuts, bolts, insulating bushings, and washers from the flanges. Save the parts. They will be needed later and must be in good condition. Separate the flange sets. 3. Remove and save the flange gaskets. 4. Install the outer flanges on the process piping, observing the dimensions noted in Figures 2 and 3. Use pipe joint compound or pipe tape to ensure the connections do not leak. 5. Install a ½ inch FNPT thermowell in the process piping within 6 ft. (1.8m) of the sensor. For best results place the thermowell as close as possible to the sensor. 6. Position the sensor between the process mating flanges with the flange gaskets inserted between each set of flanges. If the process piping is lined with a non-conductive material, a metal orifice plate (contact ring) must be installed between the flanges. Consult the factory for more information. 7. Align the bolt holes. 8. Insert an insulating sleeve in each bolt hole. See Figure 1. 9. Place a metal washer on each bolt, followed by an insulating washer. Insert the bolt through the insulating sleeve. 10. Place an insulating washer followed a metal washer on each bolt.

INSTALLATION NOTE Before tightening the bolts (step 11), be sure the flange gaskets are installed between the system piping and the sensor and that the insulating sleeves and washers are in place. For the sensor to operate properly there must no metal to metal contact between the sensor and the process piping. 11. Screw a nut onto each bolt and tighten according to the table. Follow the torquing sequence shown in Figure 1. Flange Torque 1 inch flange bolts 10 ft-lb (7.37 N-m) 2 inch flange bolts 25 ft-lb (18.43 N-m) Do not over tighten the bolts. 12. Connect the grounding strap between the two outer flanges using the screws and washers removed in step 1. If an orifice plate contact ring is being used, connect the shorting strap to the two contact rings. 13. Install the temperature sensor in the thermowell. Use Teflon tape on the pipe threads. The insertion length is adjustable from 1.4 to 4.0 inches (36 to 102 mm). The temperature sensing zone, which extends 1.3 inches (33 mm) from tip of the sensor, must be inside the thermowell DWG. NO. REV. 40008 D FIGURE 1. Toroidal Conductivity Sensor/Assembly Installation 2

INSTALLATION MILLIMETER INCH Model -01 Model -02 DWG. NO. REV. 40010 A DWG. NO. REV. 40011 B FIGURE 2. Code-01 and -02 Dimensions 3

INSTALLATION MILLIMETER INCH -05-06 DWG. NO. REV. 40012 A DWG. NO. REV. 40013 B FIGURE 3. Code-05 and -06 Dimensions 4

WIRING WIRING Keep sensor wiring away from ac conductors and high current demanding equipment. Do not cut cable. Cutting the cable may void the warranty. FIGURE 4. Wire Functions FIGURE 5. Wiring sensor to 1056 and 56 analyzers FIGURE 6. Wiring sensor to 54eC analyzer 5

WIRING FIGURE 7. Wiring sensor to Xmt-T panel mount transmitter FIGURE 8. Wiring sensor to Xmt-T pipe/wall mount transmitter TB2 TB1 RTN RCV B SENSE RCV A RTD IN SHLD RSHLD DRV B DRV A GREEN WHITE CLEAR BLACK GREEN BLACK WHITE DSHLD 228-54 FIGURE 9. Wiring sensor to 1066 transmitter FIGURE 10. Wiring sensor to 5081-T transmitter 6

WIRING WIRING THROUGH A REMOTE JUNCTION BOX FIGURE11. Wiring sensor through a remote junction box Wire cable point to point. For wiring at the analyzer end, refer to the appropriate analyzer wiring diagram. FIGURE 12. Remote Junction Box (PN 23550-00) 7

CALIBRATION CALIBRATION The nominal cell constant of the 1-inch diameter sensor is 6/cm and the nominal cell constant of the 2-inch diameter sensor is 4/cm. The error in the cell constant is about ±10%, so conductivity readings made using the nominal cell constant will have an error of at least ±10%. For higher accuracy the sensor must be calibrated. The sensor can be calibrated using a standard solution or a previously calibrated sensor and analyzer. Calibration against a standard solution requires that the sensor and outer flanges be removed from the process piping. Generally it is a useful method only when the sensor is first installed. Otherwise, the sensor should be calibrated in place against a referee sensor and analyzer. To calibrate against a standard solution, screw a short length of metal pipe into one of the outer flanges and cap the open end of the pipe. Stand the sensor on the capped end and fill it with standard to the level of the upper surface of the second outer flange. Be sure the shorting strap is connected to both flanges. Adjust the analyzer reading to match the known conductivity of the standard. Do not place a temperature sensor or any object inside the conductivity sensor during calibration. Doing so will alter the measured conductivity and introduce an error in the measurement. Once the sensor has been installed in the process piping, removing it for calibration is impractical. In this case, calibrate the sensor against a referee sensor and analyzer, ideally while both sensors are simultaneously measuring the same process liquid. If this is not practical, calibrate the sensor against the results of a measurement made on a grab sample. For more information about calibrating toroidal conductivity sensors, particularly precautions to take during in-process calibrations, refer to application sheet ADS 43-025, available on the Rosemount Analytical website. 8

TROUBLESHOOTING TROUBLESHOOTING PROBLEM PROBABLE CAUSE SOLUTION Off-scale reading Wiring is wrong. RTD is open or shorted. Sensor is damaged. Noisy reading Fluctuating process liquid level in the sensor. Sensor cable is run near high voltage conductors. Sensor cable is moving. Verify and correct wiring. Check RTD for open or shorts. See Figure 13. Perform isolation checks. See Figure 13. Perform toroid check. Confirm that the sensor is installed in the process piping so that it is always filled with liquid. Installation in a vertical pipe run with flow from the bottom is best. Move the cable away from high voltage conductors. Keep the sensor cable stationary. Reading seems wrong (lower or higher than expected) Bubbles are trapped in the sensor Sensor is not completely filled with process liquid. Cell constant is wrong. Wrong temperature correction algorithm is being used. Temperature reading is inaccurate. Measured temperature does not match temperature at the sensor. Toroids are damaged. Increase the flow if possible. Confirm that the sensor is installed in the process piping so that it is always filled with liquid. Installation in a vertical pipe run with flow from the bottom is best. Calibrate the sensor. Check that the temperature correction is appropriate for the sample. See analyzer manual for more information. Disconnect the RTD leads (Figure 13) and measure the resistance between the in and common leads. The resistance should be close to the value in Table 1. Move the thermowell and RTD closer to the sensor. Perform toroid check. 9

TROUBLESHOOTING FIGURE 13. Disconnect wires from analyzer before measuring resistance. TABLE 1. Temperature Resistance 10 C 103.9 Ω 20 C 107.8 Ω 25 C 109.7 Ω 30 C 111.7 Ω 40 C 115.5 Ω 50 C 119.4 Ω Checking toroid operation Use the following procedure to check the operation of the toroids. 1. Disconnect the shorting strap from one of the outer flanges. The conductivity reading will drop to zero. 2. Pass a short piece of heavy gauge wire through the space between the toroid assembly and the pipe. 3. Connect the ends of the wire to a resistance decade box. 4. Turn off temperature correction in the analyzer. If raw conductivity is available as a temperature compensation selection, choose raw. If raw is not available, choose manual temperature correction and set the temperature to 25 C (77 F). 5. Adjust the resistance to the values shown in the table below. The conductivity reading displayed by the analyzer should be close to the values shown. Resistance 1-inch sensor K = 6/cm 2-inch sensor K = 4/cm 100 Ω 60 ms/cm 40 ms/cm 200 Ω 30 ms/cm 20 ms/cm The toroids are working properly if increasing the resistance by a factor of two causes the displayed conductivity to decrease by a factor of two. 10

MAINTENANCE REPLACEMENT PARTS PN Description 2002557 Insulation kit, 1 inch, 150 lb flange, 2 sets (See Note) 2002558 Insulation kit, 1 inch, 300 lb flange, 2 sets (See Note) 2002559 Insulation kit, 2 inch, 150 lb flange, 2 sets (See Note) 2002560 Insulation kit, 2 inch, 300 lb flange, 2 sets (See Note) 8950101 Pt 100 RTD assembly 23294-00 Interconnecting cable, specify length (maximum 100 ft (30.5m)) Note: Each insulation kit contains two flange gaskets and sufficient insulating sleeves, insulating washers, and stainless steel washers to replace both flange seals of one sensor. The kit does not contain flange bolts or nuts. 11

The right people, the right answers, right now. ON-LINE ORDERING NOW AVAILABLE ON OUR WEB SITE http://www.raihome.com 8 Credit Cards for U.S. Purchases Only. Emerson Process Management 2400 Barranca Parkway Irvine, CA 92606 USA Tel: (949) 757-8500 Fax: (949) 474-7250 http://www.raihome.com Rosemount Analytical Inc. 2011