CORONA E / FLYPPER ELECTRONIC METER MULTI-JET



Similar documents
HYDRUS ULTRASONIC METER

SHARKY 775 COMPACT ENERGY METER ULTRASONIC

SHARKY 775 COMPACT ENERGY METER ULTRASONIC

How To Use A Corona Mdi 110

SONOMETER TM 1000 Ultrasonic compact heat meter

AMTRON E-30 Compact heat and cooling meter

IFC 070 Technical Datasheet

SHARKY 775 Ultrasonic Compact Energy Meter. Installation and User Guide

SITRANS F flowmeters SITRANS FUS080. Flowmeter FUE380 with approval. 4/202 Siemens FI Overview

How To Use A Flowmeter

SENSORS. Miniature Sensors - S3Z. Advanced line of miniature Asian style of photoelectric sensors mm background suppression

Heat meters Cooling meters

Fluxi 2000/TZ Turbine Gas Meter

Electro-Magnetic Flowmeters COPA-XT 2-Wire DT43

SITRANS F flowmeters SITRANS FUS080. SITRANS FUS380/FUE380/SONOCAL /179. flow sensor pipe, 4 transducers/transducer cables and a transmitter

Energy Management Energy Meter Type EM23 DIN

Measurement. SITRANS F US Inline. Transmitter FUS080/FUE080 4/219

Typical Aluminum GFM Mass Flow Meter

MULTICAL 21 DATA SHEET. Electronic ultrasonic cold and hot water meter

Instructions for assembly and use MULTICAL 601

Technical Specifications: The specifications represent a particular hardware platform. Application-specific software is provided.

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

BM SERIES WAVE COMPACT 6.3 GHZ CW SERIES PULSE RADAR LEVEL INSTRUMENTS (6.3 GHz)

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

A project to optimise quality and energy efficiency must include metering

Heating, air-conditioning, cooling

CONTOIL DFM 8EDM. Table of contents. Mounting and operating instructions

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits

Polyphase kwh Electricity Meter

USB-500 Series Stand-Alone, Low-Cost Data Loggers

Certified according to DIN EN ISO 9001 Technical Datasheet KVO Series Vortex Flow Meter

2CP. Twin-impeller pumps PERFORMANCE RANGE INSTALLATION AND USE APPLICATION LIMITS OPTIONALS AVAILABLE ON REQUEST CONSTRUCTION AND SAFETY STANDARDS

Description. Dimensions. Features. precision works better

How to use the OMEGALOG software with the OM-SQ2010/SQ2020/SQ2040 Data Loggers.

EGSTON Standard E2xFxWx 12W

Frequency Converter Fv

For Multi-Parameter Meters see mvx

Electronic Control Devices The European Product Catalogue 2007

EMO T. Thermal actuator for heating, ventilation and air conditioning systems

How To Use A Multi-Line Calculator With A Power Supply And Power Supply (Kamstrup)

Series 7500 Torque Sensor

3DLevelScanner II TECHNICAL DATA SHEET

Digital pressure gauge for industrial applications Model DG-10-S, Standard version Model DG-10-E, Enhanced version

User Manual V SDM220MODBUS. Single-Phase Two Module DIN rail Meters

MOUNTING AND OPERATING INSTRUCTIONS

Technical data. General specifications. Signal voltage V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output.

Series DFMT Digital Paddlewheel Flowmeter

Laser diffuse reflection light scanner with background suppression. Dimensioned drawing

Adding Pneumatic Preset Counter. Type 497. Continuously visible preset Integrated pneumatic reset 3 or 5-digit display Convenient button setting

Operating Manual UWAPS-TINY Series

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

PRO-CLEAN. Technical Description. Specifications. Space-saving design with minimum heat loss (melamine resin insulation)

Emergency lighting units EM powerled

Self-operated Temperature Regulators Temperature Regulator Type 1u

Actuator for modulating control AME 435

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

Automatic Bypass Control AVDO

Cross-beam scanning system to detect slim objects. 100 mm in

5235 Single Phase Credit Meter

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

Certified according to DIN EN ISO 9001 Technical Datasheet C-Flow Coriolis Mass Flow Meter

Counter for Energy. We make energy measurable and secure your future.

T U R B I N E G A S M E T E R

Phase Modular Finally the benefits of Modular ups are for all

Switch Actuator, 8-fold, 10 A, MDRC AT/S , GH Q R0111

HERZ-Thermal Actuators

The multi-functional integrator Supercal 531

Material: Weight: Bearing Life: Shaft Speed: Starting Torque: Mass Moment of Inertia: Shaft Loads:

Panel Meters and Controllers Modular Panel Meter Type EDM 35

is then retained absolutely without interruption.

Technical Data Sheet. 3DLevelScanner

Product Information. Gateway For Connecting EnDat Encoders to PROFIBUS-DP

Battery Powered Thermal Mass Flow Meters for Gases

WaterMAG. Electromagnetic Flowmeter for Water Applications. Model MCB10A OVERVIEW APPLICATIONS FEATURES. No. SS2-MCB

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

Technote. Frese OPTIMA Compact actuators DN10-DN32. Application. Features thermic actuators. Features motoric actuators. Approval.

Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument D

Flexible Counter Series in DIN size 24 x 48 mm

RoHS. Shock / vibration resistant. Magnetic field proof. Many variants

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

EBS852 (Contrac) Power Electronic Unit

Series description: Wilo-Yonos MAXO

Flow switches Series AD/VH

AC/DC Power Modules C B. TML Series, 20 & 40 Watt. Features. 20 Watt Models

Visions become real. Temperature control and cooling systems. The innovative and reliable solution

Dimensional drawing. Connection type IME08-1B5NOZT0S IME08-1B5NSZT0S IME08-1B5POZT0S IME08-1B5PSZT0S. 3 x 0.14 mm². brn. L+ Schließer/ Öffner M.

EFC Frequency converters

Battery Powered Thermal Mass Flow Meters for Gases

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

Electronic Control Devices The European Product Catalogue 2007

Pressure transmitter For general industrial applications Model A-10

VDL 53 - Vacuum drying oven for flammable solvents

Turbine Flow Sensor Series VTR

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter

COOL Shelf Quick Connect

Color Mark Sensor with Red or Green LED E3S-VS

Technical Information RIA14

Three Channel Optical Incremental Encoder Modules Technical Data

Displayport Extender via 2 multimode fibers LC Duplex Connector Extends Displayport Link up to 200 meters

Bulk water meters. All that counts. EnergyMetering

Transcription:

APPLICATION Fully electronic compact water meter with impeller scanning for recording volume. Highly accurate recording of all billing data at medium temperatures up to 90 C. FEATURES 4 Electronic sensor control for recording flow rate 4 Lithium battery, lifetime 10 years 4 Optical ZVEI interface equipped as standard 4 Adjustable reading date for billing 4 Rotatable integrator 4 Single-line 7-digit display for easy meter reading

ELECTRONIC - BASIC FEATURES Ambient class OIML R49 class C / MID E2 + M1 Protection class IP 54 or IP 68 for cold and warm water meter Interfaces standard Optical ZVEI Interfaces optional* M-Bus, L-Bus, pulse * Possible combinations - M-Bus / pulse - L-Bus / forward pulse - only M-Bus Note: HYDRO-SET Software for configuration of meters, readout of measured values and printout of meter logs. Available under www.hydrometer.de (Products - downloads) TECHNICAL DATA DISPLAY Display indication LCD, 7-digit Unit m³/h - l/h - m³ - l Total values 9,999.999-999,999.9-99,999.99-9,999.999 Values displayed Flow rate SUPPLY VOLTAGE Operating voltage UN VDC 3.0 (lithium battery) Battery lifetime 10 years Nominal power PN μw 30 INTERFACES - OVERVIEW Optical ZVEI interface for communication, M-Bus protocol M-Bus According to EN 1434-3. Data reading and parametriziation are via two wires with polarity reversal protection. (Meter is powered with energy via M-Bus Master) L-Bus Interface for the radio module IZAR RADIO EXTERN Pulse Output for volume (open collector) PULSE INTERFACE - SPECIFICATION Pulse rates l/pulse Decadic 0.1... 100 Display 2 digits after comma Pulse value 1 l/pulse 0.1 (factory setting) Pulse value 2 l/pulse 1 (factory setting) Pulse variants Two forward pulses; one forward and one backward pulse; pulse and direction signal Note: In the field the pulse values can be configured as desired in the specified value range. 08.08.2012 2

VOLUME- / PULSE OPEN COLLECTOR Max. frequency Hz 90 Max. input voltage V 30 Max. input current ma 27 Max. voltage drop at active output V/mA 2/27 Max. current through inactive output μa/v 5/30 Max. reverse voltage without destroying outputs V 6 Min. pulse duration ms 5.5 (at max. frequency of 90 Hz) Max. pulse duration s 2 Min. pulse pause ms 5.5 08.08.2012 3

DN 15-20 GENERAL DN 15-20 Temperature range C 30 (for cold water meter) / 90 (for warm water meter) Ambient operating temperature C 0... 55 Ambient storage temperature C -20... 55 Nominal pressure PN bar 10 / 16 Mounting position In any position Approval - Q 3 2.5 T30 MID (DE-07-MI001-PTB008) Approval - Q 3 2.5 T90 MID (LNE 12552) Approval - Q 3 4 T30/T90 MID (LNE 13629) Dynamic range (Q 3/Q 1) R 80 / 100 / 125 Approval - Q n 1.5 / 2.5-30 C National 6.131 / 97.43 Approval - Q n 1.5 / 2.5-90 C National 6.331 / 97.79 Metrological class B / C (only at 110 / 130 mm) TECHNICAL DATA Nominal diameter DN mm 15 15 20 20 20 Nominal flow rate Q 3 m³/h 2.5 2.5 4 4 4 Nominal flow rate Q n m³/h 1.5 1.5 2.5 2.5 2.5 Overall length L mm 110 165 105 130 190 Overload flow rate Q 4 m³/h 3.125 3.125 5 5 5 Transition flow rate Q 2 l/h 32 32 51 51 51 Minimum flow rate Q 1 l/h 20* 20* 32* 32* 32* Maximum flow rate (short-term) Q max m³/h 3 3 5 5 5 Transition flow rate Q t l/h 22.5 22.5 37.5 37.5 37.5 Minimum flow rate Q min l/h 15 15 25 25 25 Starting flow rate l/h 3-4 3-4 5-6 5-6 5-6 Pressure loss at Q 3 Δp mbar 615 615 620 620 620 Flow rate at 0.1 bar pressure loss m³/h 0.962 0.962 1.607 1.607 1.607 * at R 125 08.08.2012 4

DN 15-20 DIMENSIONS Nominal diameter DN mm 15 15 20 20 20 Nominal flow rate Q 3 m³/h 2.5 2.5 4 4 4 Nominal flow rate Q n m³/h 1.5 1.5 2.5 2.5 2.5 Overall length L mm 110 165 105 130 190 Overall length with coupling L2 mm 186 241 181 206 266 Connection thread on meter Inch G¾B G¾B G1B G1B G1B Connection thread of coupling Inch R½ R½ R¾ R¾ R¾ Height H mm 20 20 20 20 20 Height H1 mm 75 75 75 75 75 Diameter Ø B mm 62 62 62 62 62 Weight without coupling kg 0.8 1.3 0.8 1 1.5 Weight with coupling kg 1 1.5 1.3 1.5 2 PRESSURE LOSS GRAPH / TYPICAL ERROR GRAPH Pressure loss graph Typical error graph 08.08.2012 5

DN 25-40 HORIZONTAL GENERAL DN 25-40 HORIZONTAL Temperature range C 30 (for cold water meter) / 90 (for warm water meter) Ambient operating temperature C 0... 55 Ambient storage temperature C -20... 55 Nominal pressure PN bar 16 Mounting position Horizontal Approval MID (LNE 14587) Dynamic range (Q 3/Q 1) R 50 / 63 / 80 Approval - Q n 6 / 10-30 C National 6.131 / 97.43 Approval - Q n 6 / 10-90 C National 6.331 / 97.79 Metrological class B TECHNICAL DATA Nominal diameter DN mm 25 32 40 Nominal flow rate Q 3 m³/h 6.3 6.3 10 Nominal flow rate Q n m³/h 6 6 10 Overall length L mm 260 260 300 Overload flow rate Q 4 m³/h 7.9 7.9 12.5 Transition flow rate Q 2 l/h 125 125 200 Minimum flow rate Q 1 l/h 80* 80* 125* Maximum flow rate (short-term) Q max m³/h 12 12 20 Transition flow rate Q t l/h 480 480 800 Minimum flow rate Q min l/h 120 120 200 Starting flow rate l/h 20 20 45 Pressure loss at Q 3 Δp mbar 280 240 200 Flow rate at 1 bar pressure loss (30 C) m³/h 12 12 24 * at R 80 08.08.2012 6

DN 25-40 HORIZONTAL DIMENSIONS Nominal diameter DN mm 25 32 40 Nominal flow rate Q 3 m³/h 6.3 6.3 10 Nominal flow rate Q n m³/h 6 6 10 Overall length L mm 260 260 300 Overall length with coupling L2 mm 378 378 438 Connection thread on meter Inch G1¼B / G1½B G1½B G2B Connection thread of coupling Inch R1 / R1¼ R1 R1½ Flange diameter D mm 115-150 Hole circle diameter K mm 85-110 Number of screwholes pcs 4-4 Screwhole diameter D1 mm 18-18 Height H mm 45 45 60 Height H1 mm 110 110 115 Diameter Ø B mm 62 62 62 Weight without coupling kg 2.9 2.9 5.1 Weight with coupling kg 3.6 3.6 6.0 Weight with flanges kg 4.9-8.6 PRESSURE LOSS GRAPH / TYPICAL ERROR GRAPH Pressure loss graph Typical error graph 08.08.2012 7

DN 25-40 VERTICAL GENERAL DN 25-40 VERTICAL Temperature range C 30 (for cold water meter) / 90 (for warm water meter) Ambient operating temperature C 0... 55 Ambient storage temperature C -20... 55 Nominal pressure PN bar 16 Mounting position Rising pipe, downpipe Approval MID (LNE 14587) Dynamic range (Q 3/Q 1) R 50 / 63 / 80 Approval - Q n 6 / 10-30 C National 6.131 / 97.43 Approval - Q n 6 / 10-90 C National 6.331 / 97.79 Metrological class B TECHNICAL DATA Nominal diameter DN mm 25 32 40 Nominal flow rate Q 3 m³/h 6.3 6.3 10 Nominal flow rate Q n m³/h 6 6 10 Overall length L mm 150 150 200 Overload flow rate Q 4 m³/h 7.9 7.9 12.5 Transition flow rate Q 2 l/h 125 125 200 Minimum flow rate Q 1 l/h 80* 80* 125* Maximum flow rate (short-term) Q max m³/h 12 12 20 Transition flow rate Q t l/h 480 480 800 Minimum flow rate Q min l/h 120 120 200 Starting flow rate l/h 20 20 45 Pressure loss at Q 3 Δp mbar 280 280 240 Flow rate at 1 bar pressure loss (30 C) m³/h 12 12 24 * at R 80 08.08.2012 8

DN 25-40 VERTICAL DIMENSIONS Nominal diameter DN mm 25 32 40 Nominal flow rate Q 3 m³/h 6.3 6.3 10 Nominal flow rate Q n m³/h 6 6 10 Overall length L mm 150 150 200 Overall length with coupling L2 mm 268 268 338 Connection thread on meter Inch G1¼B G1½B G2B Connection thread of coupling Inch R1 R1¼ R1½ Height H mm 31 31 21 Height H1 mm 161 161 191 Diameter Ø B mm 62 62 62 Width A mm 146 146 185 Weight without coupling kg 3.1 3.1 5.5 Weight with coupling kg 3.7 3.7 6.7 PRESSURE LOSS GRAPH / TYPICAL ERROR GRAPH Pressure loss graph Typical error graph 08.08.2012 9