Tungsten Tip Preparation



Similar documents
PAPER CHROMATOGRAPHY

MAINS VOLTAGE DETECTOR K7101

Chemistry 119: Experiment 7. Potentiometric Titration of Ascorbic Acid in Vitamin C Tablets

MT-RJ Connectors Termination Procedure

SYMMETRIC 1A POWER SUPPLY K8042

Operator Quick Guide EC SENSOR

Recovery of Elemental Copper from Copper (II) Nitrate

BUILDINGA 1/10 SCALE FLATBED TRAILER


Total solder points: 147 Difficulty level: beginner advanced VIDEO SIGNAL CLEANER K8036 ILLUSTRATED ASSEMBLY MANUAL

COMMON LABORATORY APPARATUS

Exciting new fashionable design... POSEIDON REEF BRACELET INSTRUCTION GUIDE

K4401 SOUND GENERATOR. them at the touch of a button. Specifications

Balzers Sputter Coater SCD 050

Enzyme Pre-Lab. Using the Enzyme worksheet and Enzyme lab handout answer the Pre-Lab questions the pre-lab must be complete before beginning the lab.

ECEN 1400, Introduction to Analog and Digital Electronics

Total solder points: 205 Difficulty level: beginner advanced UNIVERSAL BATTERY CHARGER / DISCHARGER K7300 ILLUSTRATED ASSEMBLY MANUAL

400W MONO/STEREO AMPLIFIER

Total solder points: 115 Difficulty level: beginner advanced 4 CHANNEL RUNNING LIGHT K8032 ILLUSTRATED ASSEMBLY MANUAL

Total solder points: 57 Difficulty level: beginner advanced 3 TO 30VDC / 3A POWER SUPPLY K7203 ILLUSTRATED ASSEMBLY MANUAL H7203IP-1

BATTERIES 2010, 2003 by David A. Katz. All rights reserved. Permission for academic use with original copyright retained.

GUTTER MACHINE CONTROLS STANDARD

MDU SC Connector Termination Procedure

FUEL CELL EXPERIMENTATION

Installation Instructions S

Experiment 12- Classification of Matter Experiment

K8025 VIDEO PATTERN GENERATOR. Check the picture quality of your monitor or TV, ideal for adjustment or troubleshooting.

PREPARATION AND PROPERTIES OF A SOAP

Electrochemistry Revised 04/29/15

TopSky DLG Installation Manual

The Electrical Control of Chemical Reactions E3-1

Gear PEPSI CAN STOVE INSTRUCTIONS

Chem 100 Lab Experiment #9 - ACID/BASE INDICATORS

Safety, Cleaning, and Chemical Disposal Procedures

Total solder points: 129 Difficulty level: beginner advanced LIQUID LEVEL CONTROLLER K2639 ILLUSTRATED ASSEMBLY MANUAL H2639IP-1

K2570 UNIVERSAL POWER SUPPLY 5-14DC / 1A. The easy way to power your ILLUSTRATED ASSEMBLY MANUAL

200W DISCRETE POWER AMPLIFIER K8060

Electronics and Soldering Notes

7-SEGMENT DIGITAL CLOCK

Care and Use of the Compound Microscope

Mixtures and Pure Substances

Paper Chromatography: Separation and Identification of Five Metal Cations

MINI ELECTRIC SEWING MACHINE OPERATION MANUAL

Build a Junior Solar Sprint Model Car Kit Materials: 1 PITSCO Ray Catcher Sprint Kit or Solar Made Junior Solar Sprint Kit 1 White Sheet of Plastic

SPRITE and BIGFOOT DESKTOP CNC MACHINE KIT ASSEMBLY INSTRUCTIONS

DIY 3D Printing Filament

LEADER IN CUTTING TECHNOLOGY

bonus tutorial How to Make a Miniature Ice Cream Cone from Polymer Clay Access more fun tutorials at

GUITAR PREAMPLIFIER WITH HEADPHONE OUTPUT K4102

Easy Machining Center Setup

INSTRUCTIONS Edition AC

Total solder points: 167 Difficulty level: beginner advanced DMX CONTROLLED RELAY K8072 ILLUSTRATED ASSEMBLY MANUAL

Fig. 1. Background. Name: Class: Date:

Determining the Quantity of Iron in a Vitamin Tablet. Evaluation copy

EXPERIMENT 7 Electrochemical Cells: A Discovery Exercise 1. Introduction. Discussion

RayClic Connection System Installation Instructions

Sugar or Salt? Ionic and Covalent Bonds

X-ray Imaging Systems

Objectives: Vocabulary:

Total solder points: 67 Difficulty level: beginner advanced UNIVERSAL TEMPERATURE SENSOR K8067 ILLUSTRATED ASSEMBLY MANUAL

X-ray Imaging Systems

AF-C (side edge only model) Ski Edge Tuning Machine

Determination of a Chemical Formula

Tin Man Electrolysis

OPERATING INSTRUCTIONS

POCKET AUDIO GENERATOR K8065

Physical Properties of a Pure Substance, Water

FREEBIRD THE ORIGINAL D.I.Y. ORNITHOPTER! Tools and Glue. Required Materials

CHAPTER 6 WEAR TESTING MEASUREMENT

Lunette 2 Series. Curved Fixed Frame Projection Screen. User s Guide

4) Read and study the steps and illustrations first to get an overall picture of the project. Then come back and commence practice.

VCR Ion Beam Sputter Coater

Termination Procedure. FCUPC One Piece Connector

Manual for GlobePharma Mini-Press II Rotary Tablet Press

Total solder points: 18 Difficulty level: beginner advanced UNIVERSAL POWER SUPPLY 5-14DC / 1A K2570 ILLUSTRATED ASSEMBLY MANUAL

74 Chapter CO 2 Cleaning

Instructions for Using the Watch Works Tool Kit to Change a Watch Battery

DETERMINING THE MASS OF A COPPER ATOM

Electrochemical Half Cells and Reactions

Tube Control Measurement, Sorting Modular System for Glass Tube

Building Electrochemical Cells

ELECTRONIC TRANSISTOR IGNITION FOR CARS K2543

ELECTROCHEMICAL CELLS LAB

TIG torches to 3-5 Tungsten electrodes to 3-7 TIG consumables Miscellaneous

Rajesh Swaminathan. March 13, 2005

Vitamin C Content of Fruit Juice

Acid Base Titrations

Household Acids and Bases

Reaction of Magnesium with Hydrochloric Acid (Gas Laws) Chemicals Needed:

STM and AFM Tutorial. Katie Mitchell January 20, 2010

DUAL ELECTRONIC DICE K3400

Chemistry 112 Laboratory Experiment 6: The Reaction of Aluminum and Zinc with Hydrochloric Acid

Chemical Bonding: Polarity of Slime and Silly Putty

1. To perform a potentiometric titration of a sample of Liquid Drano with hydrochloric acid.


Soldering Techniques N I A G A R A C O L L E G E T E C H N O L O G Y D E P T.

View of ΣIGMA TM (Ref. 1)

Determination of Melting Points

Transcription:

1 Tungsten Tip Preparation Andra Mandru, August 2011 General aspects and observations: When performing STM measurements, the stability of the tip plays a crucial role. Therefore, a sharp tip which comes to a point rapidly is desired (see Fig. 1). With the aim of achieving these characteristics, several concentrations and applied voltages have been tried. By experiment and SEM image acquisition, it has been found that the optimal parameters for etching are a solution concentration of 8g NaOH/100ml distilled water and an applied voltage of roughly 4V. Fig. 1: SEM image of a Tungsten tip prepared in 2M NaOH solution (8g/100ml) with an applied voltage of 4.2V

2 Equipment: - tip holder (see Fig. 2); - variable voltage power supply; - etching station (see Fig. 3); - electronic scale; - optical microscope - offers a quick view of the quality of the tip (also it is a good way to check if the tip touched something after the etching and cleaning processes were completed); - ultrasonicator (ultrasonic cleaner); - beakers; - glass stirring rod; - tweezers curve tips and very fine rounded points types of tweezers have been used (see Fig. 5); ordered from Techni-Tool; - pliers - useful when: i) bending the tip, in which case the best to use are the short chain nose head pliers and ii) inserting the tip into the holder, in which needle nose or long chain nose are the best choice; both types of pliers have been ordered from Techni-Tool; - cutters - one thing worth mentioning here is that the choice of the cutters is important because of the following: when one cuts the wire from the roll, it can split at the end, making it more difficult to bend the wire and mount it onto the holder; this can be avoided by choosing cutters with full flush cutting edge; ordered from Techni-Tool; - multimeter for measuring the AC voltage which was applied between the electrodes.

3 Materials: - Tungsten wires ordered from ESPI METALS; 0.02 in diameter; - NaOH 2M grains ordered from ALFA AESAR; - distilled water obtained from OU Chemistry Department; - Isopropanol; - flexible tubing (made of thermoplastic material; useful because it is not affected by the etching process) ordered from COLE-PARMER Instrument company; dimensions: 0.020 ID, 0.083 OD, 0.0315 WALL; - graphite electrode obtained from the machine shop. Tungsten Tip Tip holder Fig. 2: Tungsten tip mounted onto the tip holder

4 Steps: 1. Put gloves on; 2. Clean all beakers and tweezers you plan on using - usually the tweezers are continuously stored in a beaker which contains Isopropanol; 3. Cut a fresh piece of the flexible tubing - the length of the tubing should be chosen such that it completely covers the part of the tungsten wire which will become the actual tip; also try not to make it flat on both sides (see the zoom in on the tubing in Fig. 3), so that you can recognize the part with the tip of the tip when the etching process is over; 4. Cut a fresh piece of wire - it is better to cut a longer wire (~2 ) since it has been observed that a higher ratio of exposed wire length to tube length prevents the tip from becoming elongated when the etching process is over; 5. Prepare the NaOH solution - weigh 16g of NaOH grains using the electronic scale; fill a clean beaker with 200 ml distilled water and pour the grains in; put the beaker into the ultrasonicator for ~ 10 minutes to allow the grains to dissolve (use a glass stirring rod if they did not dissolved completely after the 10 minutes have passed); finally, transfer the freshly prepared solution into a beaker similar to the one in Fig. 3; 6. Bend one end of the wire and make sure it is properly mounted onto the holder (a proper mounting implies no movement of the wire); remove the wire from the holder; 7. Insert the bended end of the wire into the tubing; 8. Mount the wire on the mini chuck as in Fig. 3

5 Mini chuck Tungsten wire (cathode) Flexible tubing NaOH solution Graphite electrode (anode) Fig. 3: Picture of the etching station used in preparing the tips 9. Turn the power supply on and adjust the AC voltage between the two electrodes (as mentioned before, the voltage should be ~ 4V); measure the voltage using the multimeter; turn the power supply off ;

6 10. Submerge the part with the tubing into the solution, making sure that the upper (flat) part of the tubing is very close to the surface of the solution (this will help achieving a tip that comes to a point rapidly); 11. Once you think that the upper part of the tubing is close enough to the surface of the solution, turn the power supply back on ; the etching process should begin; 12. Once the tubing (which contains the actual tip) falls off, carefully take it out of the solution with tweezers; using a piece of Tungsten wire, push the tip half way out and grab it with another pair of tweezers (see Fig. 4 and Fig. 5); the cleaning process should start immediately; Freshly prepared Tungsten Tip Tungsten wire Fig. 4: Picture illustrating how the freshly prepared tip is pushed out of the flexible tubing, by making use of another Tungsten wire

7 Fig. 5: Taking the Tungsten wire out of the tubing right before the cleaning process begins 13. While holding the freshly prepared tip with tweezers, clean it in distilled water and then in Isopropanol (using the ultrasonicator, for about 1 minute) as shown in Fig. 6; make sure to prevent the tip of the tip from touching any surface (this can be checked by using the optical microscope - see Fig. 7 for a comparison between a tip that did not touch any surface and one that did);

8 14. After using the microscope, clean the tip again in Isopropanol following the same procedure as in the previous step; 15. Carefully mount the tip onto the holder (Fig. 2) and make sure it is fixed in place. Tungsten Tip Beaker filled with distilled water or Isopropanol Fig. 6: Cleaning of the tip in distilled water and in Isopropanol; the beaker should be used inside the ultrasonicator

9 (a) (b) Fig. 7: Picture of the optical microscope image showing (a) a tip which did not come in contact with any surface and (b) one that did Note: Due to the high degree of oxidation of Tungsten, it is advisable to transfer the freshly prepared tips into the chamber as soon as possible.