Voltage Stability Improvement using Static Var Compensator in Power Systems



Similar documents
Chapter 3 AUTOMATIC VOLTAGE CONTROL

The design and performance of Static Var Compensators for particle accelerators

A COMPARISON ON PERFORMANCE OF TCSC/SSSC FOR A RADIAL SYSTEM

Analysis of the Effect of Tap Changing Transformer on Performance of SVC

Reactive Power and Importance to Bulk Power System OAK RIDGE NATIONAL LABORATORY ENGINEERING SCIENCE & TECHNOLOGY DIVISION

Topics. HVDC Fundamentals

EMTP STUDIES PERFORMED TO INSERT LONG AC CABLES IN THE FRENCH GRID

Knowing the FACTS. FACTS that enhance power quality in rail feeder systems

FACTS. Solutions to optimise network performance GRID

CO-ORDINATION OF PARALLEL AC-DC SYSTEMS FOR OPTIMUM PERFORMANCE

COMPARISON OF THE FACTS EQUIPMENT OPERATION IN TRANSMISSION AND DISTRIBUTION SYSTEMS

HVDC 2000 a new generation of high-voltage DC converter stations

LAB1 INTRODUCTION TO PSS/E EE 461 Power Systems Colorado State University

Chapter 4 AC to AC Converters ( AC Controllers and Frequency Converters )

INTERNATIONAL JOURNAL OF ELECTRICAL ENGINEERING & TECHNOLOGY (IJEET)

System Protection Schemes in Eastern Denmark

Study to Determine the Limit of Integrating Intermittent Renewable (wind and solar) Resources onto Pakistan's National Grid

FACT SHEET. BSES, Delhi - Distribution Network. Power Systems Consultancy from ABB

Transient analysis of integrated solar/diesel hybrid power system using MATLAB Simulink

Power System review W I L L I A M V. T O R R E A P R I L 1 0,

Distributed Flexible AC Transmission System (D FACTS) Jamie Weber ext. 13

Control Development and Modeling for Flexible DC Grids in Modelica

Current and Temperature Ratings

MINISTERIE VAN ECONOMISCHE ZAKEN GENERAL COST COMPARISON BETWEEN UNDERGROUND CABLES AND O.H. LINE SYSTEMS FOR H.V. TRANSMISSION

Bill is the author of 15 papers and lectures on transmission lines and other power system topics.

Project description. Power Electronics for Reliable and Energy efficient Renewable Energy Systems

2012 San Francisco Colloquium

Keywords: Electric circuits, passive circuits, active circuits, voltage source inverter, reactive power theory, active filters.

Power Technology Issue 104. Modeling of Two-Winding Voltage Regulating Transformers for Positive Sequence Load Flow Analysis in PSS E

PHASOR DIAGRAMS HANDS-ON RELAY SCHOOL WSU PULLMAN, WA. RON ALEXANDER - BPA

Frequency response: Resonance, Bandwidth, Q factor

Limiting Grid Disturbances of Renewable Power Sources b.m.o Modern Power Electronics Paper ID FT3-5.2; , 16h30-17h00

Preliminary Feasibility Assessment For. The Rio Tinto Alcan to BCH Transfer Limit of 460 MW. With 50% Series Compensation on Both KMO KIT lines

POWER SYSTEM HARMONICS. A Reference Guide to Causes, Effects and Corrective Measures AN ALLEN-BRADLEY SERIES OF ISSUES AND ANSWERS

OPTIMAL DISPATCH OF POWER GENERATION SOFTWARE PACKAGE USING MATLAB

Three phase circuits

Product Data Bulletin

Fault Analysis I PowerWorld Corporation

Power Electronics. Prof. K. Gopakumar. Centre for Electronics Design and Technology. Indian Institute of Science, Bangalore.

STATCOM Application at VELCO Essex Substation

Generation Interconnection Feasibility Study Report-Web Version. PJM Generation Interconnection Request Queue Position Z1-055

POWER TRANSMISSION FROM OFFSHORE WIND FARMS

A Fuzzy Based Solution for Improving Power Quality in Electric Railway Networks

AC Power. by Prof. Dr. Osman SEVAİOĞLU Electrical and Electronics Engineering Department

Introduction to PowerWorld Simulator: Interface and Common Tools

Application Note AN- 1095

GPS Interfacing of Banediya Feeder (M.P) Using MI Power Software

Steady-State Power System Security Analysis with PowerWorld Simulator

SVC LIGHT: A POWERFUL MEANS FOR DYNAMIC VOLTAGE AND POWER QUALITY CONTROL IN INDUSTRY AND DISTRIBUTION.

Power Factor Correction for Power Systems First Semester Report Spring Semester 2007

Chapter 19 Resonant Conversion

A Live Black-start Capability test of a Voltage Source HVDC Converter

Utility Static Var Compensator (SVC)

CYCLOCONVERTERS. Fig.1 Block diagram of a cycloconverter

(3 )Three Phase Alternating Voltage and Current

Reactive Power Generation by DFIG Based Wind Farms with AC Grid

Dynamic Security Assessment in the Future Grid. Vijay Vittal Ira A. Fulton Chair Professor Arizona State University

APPLICATION NOTE ULTRASONIC CERAMIC TRANSDUCERS

Basics of Electricity

Grid Interconnection of Renewable Energy Sources Using Modified One-Cycle Control Technique

SAMPLE OF THE STUDY MATERIAL PART OF CHAPTER 3. Symmetrical Components & Faults Calculations

DIMENSIONING OF CURRENT TRANSFORMERS FOR PROTECTON APPLICATION

Understanding Power Factor and How it Affects Your Electric Bill. Presented by Scott Peele PE

Transformers. Special transformers Reactors products

Using the Impedance Method

RLC Resonant Circuits

Application Guide. Power Factor Correction (PFC) Basics

HVDC Light, a tool for electric power transmission to distant loads

Typical Data Requirements Data Required for Power System Evaluation

Improvements of Reliability of Micro Hydro Power Plants in Sri Lanka

CT Application Guide for the 489 Generator Management Relay

General Validation Test Program for Wind Power Plants Connected to the Hydro-Québec Transmission System

Since any real component also has loss due to the resistive component, the average power dissipated is 2 2R

Impedance Matching and Matching Networks. Valentin Todorow, December, 2009

EMC STANDARDS STANDARDS AND STANDARD MAKING BODIES. International. International Electrotechnical Commission (IEC)

Appendix N: GENERATOR DATA SHEET FOR SYNCHRONOUS GENERATORS CONNECTED TO PG&E ELECTRIC SYSTEM

Application of SVCs by CenterPoint Energy to Address Voltage Stability Issues: Planning and Design Considerations

Electrical Resonance

Let s examine the response of the circuit shown on Figure 1. The form of the source voltage Vs is shown on Figure 2. R. Figure 1.

Voltage regulation in distribution systems - Tap changer and Wind Power

2Azerbaijan Shahid Madani University. This paper is extracted from the M.Sc. Thesis

DC TRANSMISSION BASED ON VOLTAGE SOURCE CONVERTERS

Keywords: synchronous generator, synchronous motor, automatic voltage regulator, V- curves, synchronizing power, hunting, excitation system

CIRCUITS LABORATORY EXPERIMENT 3. AC Circuit Analysis

TA Kahraman Yumak ELK412 - Distribution of Electrical Energy Lab. Notes v Spring web.itu.edu.tr/yumakk. Distance Protection

Advance Electronic Load Controller for Micro Hydro Power Plant

Introduction. Harmonics and IEEE 519 Page 1 of 19

Circuits with inductors and alternating currents. Chapter 20 #45, 46, 47, 49

3-Phase Synchronous PWM Controller IC Provides an Integrated Solution for Intel VRM 9.0 Design Guidelines

VOLTAGE REGULATOR AND PARALLEL OPERATION

LABORATORY 10 TIME AVERAGES, RMS VALUES AND THE BRIDGE RECTIFIER. Bridge Rectifier

HVDC Technology for Large Scale Offshore Wind Connections

Analysis of AC-DC Converter Based on Power Factor and THD

EssPro Energy Storage Grid Substation The power to control energy

Distributed Generation and Power Quality Case Study

Phasors. Phasors. by Prof. Dr. Osman SEVAİOĞLU Electrical and Electronics Engineering Department. ^ V cos (wt + θ) ^ V sin (wt + θ)

ENDOKS ENERGY SYSTEMS POWER QUALITY PROJECTS REFERENCE LIST

INTRODUCTION TO SYSTEM PROTECTION. Hands-On Relay School 2012

Transcription:

Leonardo Journal of Sciences ISSN 1583-0233 Issue 14, January-June 2009 p. 167-172 Voltage Stability Improvement using Static Var Compensator in Power Systems Department of Electrical/Computer Engineering, Federal University of Technology, Minna, Niger State, Nigeria E-mail: mnnwohu@yahoo.com Abstract This paper investigates the effects of Static Var Compensator (SVC) on voltage stability of a power system. The functional structure for SVC built with a Thyristor Controlled Reactor (TCR) and its model are described. The model is based on representing the controller as variable impedance that changes with the firing angle of the TCR. A Power System Computer Aided Design /Electromagnetic Transients including DC (PSCAD/EMTDC) is used to carry out simulations of the system under study and detailed results are shown to access the performance of SVC on the voltage stability of the system. Keywords Thyristor; Transmission; Simulations; Stability; Voltage. Introduction Today s changing electric power systems create a growing need for flexibility, reliability, fast response and accuracy in the fields of electric power generation, transmission, distribution and consumption. Flexible Alternating Current Transmission Systems (FACTS) are new devices emanating from recent innovative technologies that are capable of altering http://ljs.academicdirect.org 167

Voltage Stability Improvement using Static Var Compensator in Power Systems voltage, phase angle and/or impedance at particular points in power systems. Their fast response offers a high potential for power system stability enhancement apart from steadystate flow control. Among the FACTS controllers, Static Var Compensator (SVC) provides fast acting dynamic reactive compensation for voltage support during contingency events which would otherwise depress the voltage for a significant length of time. SVC also dampens power swings and reduces system losses by optimized reactive power control. Power System Computer Aided Design/Electromagnetic Transients Direct Current (PSCAD/EMTDC) has been used in this paper to conduct simulations on voltage regulation at the point of connection of SVC to the system. However, the aim of this paper is to enhance voltage stability using Static Var Compensator at the event of occurrence of fault in the system. Model of SVC with PSCAD Representation of Its Control In order to investigate the impact of SVC on power systems, appropriate SVC model is very important. In this section, SVC and its mathematical model will be introduced. SVC is built up with reactors and capacitors, controlled by thyristor valves which are in parallel with a fixed capacitor bank. It is connected in shunt with the transmission line through a shunt transformer and thus, represented in Figure 1 [1]. Figure 2 shows the equivalent circuit at which SVC is modeled [2, 3]. Figure 1. Functional diagram of SVC Figure 2. Equivalent circuit of SVC 168

Leonardo Journal of Sciences ISSN 1583-0233 Issue 14, January-June 2009 p. 167-172 The model considers SVC as shunt-connected variable susceptance, B SVC which is adapted automatically to achieve the voltage control. The equivalent susceptance, B eq is determined by the firing angle α of the thyristors that is defined as the delay angle measured from the peak of the capacitor voltage to the firing instant. The fundamental frequency equivalent neglecting harmonics of the current results in [4]: where eq L( α) Bc B = B + (1) ( 2α) 0 0 1 2α sin B ( α ) ωl π π If the real power consumed by the SVC is assumed to be zero, then: P Q L = 1, Bc = ωc and 0 α 90 SVC SVC = 0 = V 2 B SVC where V is the bus voltage magnitude. As the reactive power demand at the bus varies, the susceptance is varied subject to the limits. However, the reactive power is a function of the square of the bus voltage. Hence the reactive power generated decreases as the voltage decreases. (2) Svc Control Scheme Figure 3. PSCAD representation of SVC control system [5] The SVC can both absorb as well as supply reactive power at the bus it is connected to by control of the firing angle of the thyristor elements. By controlling the firing angle α of the 169

Voltage Stability Improvement using Static Var Compensator in Power Systems thyristors (i.e., the angle with respect to the zero crossing of the phase voltage), the device is able to control the bus voltage magnitude. Changes in α results in changes on the current and hence, the amount of reactive power consumed by the inductor. When α = 90, the inductor is fully activated but is deactivated when α = 180. Actually, the basic control strategy is typically to keep the transmission bus voltage within certain narrow limits defined by a controller droop and the firing angle α limits (90 < α > 180 ). Studied System Figure 4. A 230kV power system with SVC connected at bus 3 Figure 4 shows a 230kV power network to which SVC is connected at bus 3. The power system comprises a generator generating 16kV which is stepped up by a transformer to 230kV. This voltage is transmitted via the transmission line to bus 3. The models of the generator and the SVC as well as the transformer parameters are the IEEE standard models of PSCAD/EMTDC [5]. Simulation and Results The system under study is carried out in PSCAD/EMTDC when the generator is operating at its rated power level. The voltage at bus 3 having a load of 4MW and 3MVar is found approximately to be 230kV. But, when the load is increased to 150MW and 30MVar, 170

Leonardo Journal of Sciences ISSN 1583-0233 Issue 14, January-June 2009 p. 167-172 the voltage dropped to 229.151kV. So, further increase in load resulted in the corresponding voltage drop at bus 3 as is shown in Table 1. Table 1. Load variation with and without SVC Loads Voltages in kv MW MVar Without SVC With SVC 4 3 229.977 230.350 150 30 229.151 230.618 155 35 229.014 232.048 160 40 228.877 229.065 260 60 228.286 231.154 Figure 5. The firing angle at the same load with P = 4MW and Q = 3MVars Figure 6. Reactive power flow at the load with P = 4MW and Q = 3MVars 171

Voltage Stability Improvement using Static Var Compensator in Power Systems However, with SVC connected to bus 3, the voltage required (230kV) is maintained even at the increase of load. It is observed that the voltage magnitude at bus 3 is maintained averagely to 230.65kV during load variation. When SVC is unconnected, the firing angle is 180 showing that the inductor is deactivated. However, the inductor is activated when SVC is connected and the firing angle is 116.9, hence optimizing the reactive power and improving the voltage profile (See figures 5 6). It should be noted here that changes in firing angle result on changes in the current, and hence the amount of reactive power consumed by the inductor. As the load increases, the firing angle decreases and hence more amount of reactive power is consumed by the inductor, and vice versa. Conclusion In this paper, the basic structure of an SVC operating under typical bus voltage control and its model are described. The model is based on representing the controller as variable impedance that changes with the firing angle of the Thyristor Controlled Reactor (TCR), which is used to control voltage in the system. Simulations carried out confirmed that Static Var Compensator could provide the fast acting voltage support necessary to prevent the possibility of voltage reduction and voltage collapse at the bus to which it is connected. References 1. Cai L., Robust Co-ordinated Control of FACTS Devices in Large Power Systems a PhD thesis, University of Duisburg, Germany, published by Logos Verlag Berlin, 2004. 2. Acha E., Ambriz-Perez H., Fuerte-Esquivel, Advanced SVC Models for Newton-Raphson Load Flow and Newton Optimal Power Flow Studies, IEEE Transactions on Power Systems, 15(1), p.129-136, 2000. 3. Agelidis V. G. et all., Power Electronic Control in Electrical Systems, Newnes, 2002. 4. Hingorani N. G., Gyugyi L., Understanding FACTS concepts and Technology of flexible AC transmission systems, New York. IEEE Press, 2000. 5. Manitoba H. V. D. C. Research centre Inc., PSCAD/EMTDC manual version 3.0, 244 Cree Crescent, Winnipeg, Manitoba, Canada R3J 3W1. 172