11.1.1 Non-Colinear Pump-Probe Measurement: Pump pulse. Chopper. Lens. Probe pulse. Time delay between pump and probe pulse



Similar documents
Broadband THz Generation from Photoconductive Antenna

Pump-probe experiments with ultra-short temporal resolution

Scanning Near Field Optical Microscopy: Principle, Instrumentation and Applications

A Guide to Acousto-Optic Modulators

SPATIAL-TIME PATTERN OF ELECTRICAL FIELD OF TERAHERTZ PULSE IN THE FAR FIELD

A More Efficient Way to De-shelve 137 Ba +

Limiting factors in fiber optic transmissions

Acousto-optic modulator

ULTRAFAST LASERS: Free electron lasers thrive from synergy with ultrafast laser systems

Robert G. Hunsperger. Integrated Optics. Theory and Technology. Fourth Edition. With 195 Figures and 17 Tables. Springer

Self-Mixing Laser Diode Vibrometer with Wide Dynamic Range

Raman Spectroscopy Basics

F en = mω 0 2 x. We should regard this as a model of the response of an atom, rather than a classical model of the atom itself.

University of Pécs in ELI

Suppression of Four Wave Mixing in 8 Channel DWDM System Using Hybrid Modulation Technique

PHYSICAL METHODS, INSTRUMENTS AND MEASUREMENTS Vol. IV Femtosecond Measurements Combined With Near-Field Optical Microscopy - Artyom A.

Lab 9: The Acousto-Optic Effect

Synthetic Sensing: Proximity / Distance Sensors

The front end of the receiver performs the frequency translation, channel selection and amplification of the signal.

INTRODUCTION FIGURE 1 1. Cosmic Rays. Gamma Rays. X-Rays. Ultraviolet Violet Blue Green Yellow Orange Red Infrared. Ultraviolet.

Nuclear Magnetic Resonance

Millijoules high master-slave pulse ratio 532 nm picosecond laser

Antennas & Propagation. CS 6710 Spring 2010 Rajmohan Rajaraman

5. Scanning Near-Field Optical Microscopy 5.1. Resolution of conventional optical microscopy

Projects. Objective To gain hands-on design and measurement experience with real-world applications. Contents

Experiment 5. Lasers and laser mode structure

NEAR FIELD OPTICAL MICROSCOPY AND SPECTROSCOPY WITH STM AND AFM PROBES

Ultrafast Optical Characterization of Novel Mid-Infrared Nanoscale Structures

Ti:Sapphire Lasers. Tyler Bowman. April 23, 2015

Specifying Plasma Deposited Hard Coated Optical Thin Film Filters. Alluxa Engineering Staff

Scalable Frequency Generation from Single Optical Wave

Fiber optic communication

Analysis and Improvement of Mach Zehnder Modulator Linearity Performance for Chirped and Tunable Optical Carriers

AM TRANSMITTERS & RECEIVERS

Optical Fibres. Introduction. Safety precautions. For your safety. For the safety of the apparatus

Development of an intense THz source using tilted pulse front method in LiNbO 3 crystal and its application in non-linear THz spectroscopy

Keywords: Slot antenna, ultra wideband (UWB), Microstrip line feeding, HFSS Simulation software.

INTRODUCTION TO COMMUNICATION SYSTEMS AND TRANSMISSION MEDIA

T = 1 f. Phase. Measure of relative position in time within a single period of a signal For a periodic signal f(t), phase is fractional part t p

Self-Guided Intense Laser Pulse Propagation in Air

Laser-induced surface phonons and their excitation of nanostructures

Copyright 2000 IEEE. Reprinted from IEEE MTT-S International Microwave Symposium 2000

PUMPED Nd:YAG LASER. Last Revision: August 21, 2007

Development of Optical Wave Microphone Measuring Sound Waves with No Diaphragm

Optical Communications Research Group Department of Electronic and Computer Engineering University of Limerick, Ireland b

It has long been a goal to achieve higher spatial resolution in optical imaging and

Various Technics of Liquids and Solids Level Measurements. (Part 3)

Scanning Near-Field Optical Microscopy for Measuring Materials Properties at the Nanoscale

Avalanche Photodiodes: A User's Guide

Characteristic and use

Different Types of Dispersions in an Optical Fiber

THz Imaging: Biomedical Applications

Real-world applications of intense light matter interaction beyond the scope of classical micromachining.

Finite Difference Time Domain and BPM: Flexible Algorithm Selection Technology

Sampling Theorem Notes. Recall: That a time sampled signal is like taking a snap shot or picture of signal periodically.

Diode Applications. by Kenneth A. Kuhn Sept. 1, This note illustrates some common applications of diodes.

High-Frequency Engineering / Photonics

Precision Diode Rectifiers

Fiber Optics: Fiber Basics

PIPELINE LEAKAGE DETECTION USING FIBER-OPTIC DISTRIBUTED STRAIN AND TEMPERATURE SENSORS WHITE PAPER

Implementation of Digital Signal Processing: Some Background on GFSK Modulation

Timing Errors and Jitter

Module 13 : Measurements on Fiber Optic Systems

Engineering Sciences 151. Electromagnetic Communication Laboratory Assignment 3 Fall Term

Scientific Exchange Program

SFG spectrometers. Sum Frequency Generation Vibrational Spectroscopy. More than 20 years experience

Experimental results for the focal waveform and beam width in the focusing lens with a 100 ps filter

The Role of Electric Polarization in Nonlinear optics

Department of Electrical and Computer Engineering Ben-Gurion University of the Negev. LAB 1 - Introduction to USRP

Amplifier for Small Magnetic and Electric Wideband Receiving Antennas (model AAA-1B)

Preview of Period 3: Electromagnetic Waves Radiant Energy II

Self-Mixing Differential Laser Vibrometer

Interferometric Measurement of Dispersion in Optical Components

PHYS 331: Junior Physics Laboratory I Notes on Noise Reduction

SEMICONDUCTOR lasers with optical feedback have

RAY TRACING UNIFIED FIELD TRACING

Optical Communications

Introduction to Receivers

Laser Based Micro and Nanoscale Manufacturing and Materials Processing

Time out states and transitions

Selected Radio Frequency Exposure Limits

Germanium Diode AM Radio

OPTICAL FIBERS INTRODUCTION

NUCLEAR MAGNETIC RESONANCE. Advanced Laboratory, Physics 407, University of Wisconsin Madison, Wisconsin 53706

LM1596 LM1496 Balanced Modulator-Demodulator

Concept 2. A. Description of light-matter interaction B. Quantitatities in spectroscopy

An optical pump-probe technique for measuring the thermal conductivity of liquids

AMPLIFIED HIGH SPEED FIBER PHOTODETECTOR USER S GUIDE

ELECTRICAL ENGINEERING

Four Wave Mixing in Closely Spaced DWDM Optical Channels

GLOBAL COLLEGE OF ENGINEERING &TECHNOLOGY: YSR DIST. Unit VII Fiber Optics Engineering Physics

Nexus Technology Review -- Exhibit A

- thus, the total number of atoms per second that absorb a photon is

THE FIBRE-OPTICS TRAINER MANUAL

Transcription:

Chapter 11 Ultrafast Measurement Techniques 11.1 Pump Probe Measurements 11.1.1 Non-Colinear Pump-Probe Measurement: Mode-locked Laser Beam splitter Chopper Probe pulse Pump pulse Lens Test device Slow detector 1 fs <=> 0.15 µm t Time delay between pump and probe pulse Lock-In Amplifier translation stage t Computer screen Figure 11.1: Non-colinear pump-probe setup with co-polarized pump-probe beams. Adapted from U. Keller. Figure 11.1 shows a non-colinear pump-probe measurement setup. To suppress background light and low frequency noise of the probe beam the pump 371

372 CHAPTER 11. ULTRAFAST MEASUREMENT TECHNIQUES beam is chopped. Typical chopper frequencies of regular mechanical choppers are f ch =100Hz 2kHz. Mechanical choppers up to 20kHz have been built. With acousto-optic modulators or electro-optic modulators chopper freuqencies up to several hundred MHz are possible. Lets denote S in = S 0 + δs astheprobepulseenergy,wheres 0 is the average value and δs a low frequency noise of the pulse source and is the probe signal transmitted through the test device. Then the detected signal transmitted through the test device can be written as = T (P (t))s in (11.1) = T 0 S in + dt dp (P 0m(t)) where T 0 is the transmission without pump pulse, P 0 is the pump pulse energy and m(t) the chopper modulation function. It is obvious that if the noise of the probe laser δs is of low freuqency, then the signal can be shifted away from this noise floor by chosing an appropriately large chopper frequency in m(t). Ideally, the chopper frequency is chosen large enough to enable shot noise limited detection. Sometimes the test devices or samples have a rough surface and pump light scattered from the surface might hit the detector. This can be partially suppressed by orthogonal pump and probe polarization This is a standard technique to understand relaxation dynamics in condensed matter, such as carrier relaxation processes in semiconductors for example. 11.1.2 Colinear Pump-Probe Measurement: Sometimes pump and probe pulses have to be collinear, for example when pump probe measurements of waveguide devices have to be performed. Then pump and probe pulse, which might both be at the same center wavelength have to be made separable. This can be achieved by using orthogonal pump and probe polarization as shown in Figure 11.2 or by chopping pump and probe at different frequencies and detecting at the difference frequency, see Figure 11.3.

11.1. PUMP PROBE MEASUREMENTS 373 Mode-Locked Laser Chopper PBS Probe pulse Pump pulse Lens Test device PBS λ/2-plate t Slow detector Lock-In Amplifier t Figure 11.2: Colinear pump-probe with orthogonally polarized pump and probe beams. Adapted from U. Keller. MLL Chopper f 1 Probe pulse Pump pulse Lens t Test device Slow detector Chopper f 2 Lock-In Amplifier at f - f 1 2 Figure 11.3: Colinear pump probe with chopping of pump and probe and lock-in detection at the difference frequency. Adapted from U. Keller.

374 CHAPTER 11. ULTRAFAST MEASUREMENT TECHNIQUES 11.1.3 Heterodyne Pump Probe The lock-in detection is greatly improved if the difference frequency at which the detection occurs can be chosen higher and the signal can be filtered much better using a heterodyne receiver. This is shown in Figure 11.4, where AOM s are used to prepare a probe and reference pulse shiftet by 39 and 40 MHz respectively. The pump beam is chopped at 1kHz. After the test device the probe and reference pulse are overlayed with each other by delaying the referencepulseinamichelson-interferometer. Thebeatnoteat1MHzis downconverted to base band with a receiver. MLL Chopper AOM Probe pulse Test device Pump pulse Reference t T>>t +39 Mhz Probe AOM +40 MHz Reference Slow detector 1 MHz Receiver Lock-In Amplifier t Figure 11.4: Colinear pump probe measurement with parallel polarization and large difference frequency. Adapted from U. Keller. If a AM or FM receiver is used and the interferometers generating the reference and probe pulse are interferometerically stable, both amplitude and phase nonlinearities can be detected with high signal to noise.

11.1. PUMP PROBE MEASUREMENTS 375 MLL Chopper AOM Probe pulse Test device Pump pulse Reference t T>>t PZT +39 Mhz Probe AOM +40 MHz Reference Slow detector 1 MHz Ham Radio Reciver AM or FM Lock-In Amplifier t Figure 11.5: Heterodyne pump probe using AM and FM receiver to detect amplitude and phase nonlinearities. Adapted from U. Keller.

376 CHAPTER 11. ULTRAFAST MEASUREMENT TECHNIQUES 11.2 Electro-Optic Sampling: Electro-Optic Sampling was invented by Valdmanis and Mourou in the early 1980 s [8][5]. Its is based on polarization rotation of a short laser pulse when propagating in a medium showing a linear electro-optic effect. The polarization rotation is due to an applied electric filed, i.e. the optical pulse samples the instantaneous electric field, see Fig.11.6 External Electro-Optic Sampling Scheme Probe beam in (arrive at delayed times of t+n. t) Probe Beam Out Excitation pulses (arrive at time t) Electro-Optic Probe Crystal Semiconductor Substrate Switch Bias Figure 11.6: Electro-optic sampling scheme according ot J. Whitaker, Univ. of Michigan, Ann Arbor. Figure by MIT OCW. In Fig. 11.6 a electic transient is generated with a photo-conductive switch activated by a femtosecond laser pulse. A delayed pulse samples the transient electronic pulse with an electro-optic probe as shown in Fig. 11.7.

11.2. ELECTRO-OPTIC SAMPLING: 377 Electro-Optic Probe Fused Silica Support Probe Beam LiTaO 3 Electro-Optic Crystal Figure 11.7: LiTaO 3 Electro-Otpic Probe according to J. Whitaker, Univ. Michigan. Figure by MIT OCW. Fig. 11.8 shows an overal version of an electro-optic sampling system according to J. Whitaker, Univ. of Michigan [6] Electro-Optic Sampling System Schematic To Lock-In Amplifier Detectors Eyepiece Fiber Analyzer Illumination Laser Lens Polarizer Dichroic Beam Splitter Delay Trigger Beam Bias Circuit Probe tip Figure 11.8: Electro-Otpic Sampling System according to J. Whitaker, Univ. Michigan. Figure by MIT OCW.

378 CHAPTER 11. ULTRAFAST MEASUREMENT TECHNIQUES 11.3 THz Spectroscopy and Imaging Photo-conductive switches activated by sub-100 fs pulses or optical rectification with sub-100 fs pulses leads to the generation of THz electro-magnetic impulses, that can be received with similar photo-conductive receivers or by electro-optic sampling [8][9]. This technique was pioneered by Ch. Fattinger and D. Grischkowsky [7]. Delay Femtosecond Laser Ti:sapphire or Cr:LiSAF 50-100 fs THz Transmitter THz Detector V Sample Laser Pulse LT-GaAs Substrate Dielectrics, Tissue, IC-Packaging etc. Current Figure 11.9: THz Time Domain Spectroscopy according to [8] Figure by MIT OCW.

11.3. THZ SPECTROSCOPY AND IMAGING 379 Delay GaInAs/GaAs/AlAs 12 fs Ti:sapphire Oscillator E 2 E 1 Optical Rectification in GaAs FIR - Probe: 15 fs ~ 5-15 µm 15 fs ~ 60 THz 6 fs > 100 THz QW THz -OPOs THz -OPAs Quantum-Cascade Laser Figure 11.10: THz Time Domain Spectroscopy using optical rectification in GaAs [9]. Figure by MIT OCW. Figure 11.11: Terahertz waveforms modified by passage through (a) a 10mm block of stycast and (b) a chinese fortune cookie. The dashed lines show the shape of the input waveform multiplied by 0.5 in (a) and by 0.1 in 9b). In *a( the transmitted plse exhibits a strong "chirp" due to frequency-dependent index, while in (b), pulse broadening indicates preferential absorption of high frequencies [8]. Figure 11.11 shows typical generated THz waveforms and distortions due to propagation through materials.

380 CHAPTER 11. ULTRAFAST MEASUREMENT TECHNIQUES 11.4 Four-Wave Mixing A more advanced ultrafast spectroscopy technique than pump-probe is fourwave mixing (FWM). It enables to investigate not only energy relaxation processes, as is the case in pump-probe measurements, but also dephasing processes in homogenous as well as inhomogenously broadened materials. The typical set-up is shown in Fig. 11.12 t 23 t 12 Pulse 2 Sample k 1 Pulse 3 Pulse 1 k 3 k 2 k 3 + ( k 2 - k 1 ) Detector Figure 11.12: Typical Four-Wave-Mixing (FWM) beam geometry. Lets assume these pulses interact resonantely with a two-level system modelled by the Bloch Equations derived in chapter 2 (2.1592.162). µ 1 2 E (+) (z,t) c 2 0 t 2 = 2 µ 0 P t (+) (z, t), 2 (11.2) P (+) (z,t) = 2N M d(z,t) (11.3) d(z,t) = ( 1 jω eg )d + 1 M T 2 2j~ E (+) w, (11.4) ẇ(z,t) = w w 0 T 1 + 1 j~ ( M E ( ) d M E (+) d )(11.5) The two-level system, located at z =0, will be in the ground state, i.e. d(t =0)=0and w(t =0)= 1, before arrival of the first pulses. That is, no polarization is yet present. Lets assume the pulse interacting with the two-level system are weak and we can apply perturbation theory. Then the arrival of the first pulse with the complex field E (+) ( x, t) = E (+) 0 δ(t)e j(ωegt j k 1 x) (11.6)

11.4. FOUR-WAVE MIXING 381 will generate a polarization wave according to the Bloch-equations M d( x, t) = E (+) 0 2j~ ej(ω eg 1/T 2 )t e j k 1 x δ(z), (11.7) which will decay with time. Once a polarization is created the second pulse will change the population and induce a weak population grating M E (+) 0 2 w( x, t) = e t 12/T 2 e j( k 1 k 2) x e (t t 2)/T 1 δ(z)+c.c., (11.8) ~ 2 When the third pulse comes, it will scatter of from this population grating, i.e. it will induce a polarization, that radiates a wave into the direction k3 + k 2 k 1 according to M d( x, t) = E (+) 0 2j~ M E (+) 0 2 ~ 2 e t 12/T 2 e t 32/T 1 e j ( k 3 + k 2 k 1) x δ(z) (11.9) Thus the signal detected in this direction, see Fig. 11.12, which is proportional to the square of the radiating dipole layer d( x, t) 2 e 2t 12/T 2 e 2t 32/T 1 (11.10) will decay on two time scales. If the time delay between pulses 1 and 2, t 12, is only varied it will decay with the dephasing time T 2 /2. If the time delay betweenpulses2and3isvaried,t 32, the signal strength will decay with the energy relaxation time T 1 /2

382 CHAPTER 11. ULTRAFAST MEASUREMENT TECHNIQUES

Bibliography [1] K. L. Hall, G. Lenz, E. P. Ippen, and G. Raybon, "Heterodyne pumpprobe technique for time-domain studies of optical nonlinearities in waveguides," Opt. Lett. 17, p.874-876, (1992). [2] K.L.Hall,A.M.Darwish,E.P.Ippen,U.KorenandG.Raybon,"Femtosecond index nonlinearities in InGaAsP optical amplifiers," App. Phys. Lett. 62, p.1320-1322, (1993). [3] K. L. Hall, G. Lenz, A. M. Darwish, E. P. Ippen, "Subpicosecond gain and index nonlinearities in InGaAsP diode lasers," Opt. Comm. 111, p.589-612 (1994). [4] J. A. Valdmanis, G. Mourou, and C. W. Gabel, Picosecond electro-optic sampling system, Appl. Phys. Lett. 41, p. 211-212 (1982). [5] B. H. Kolner and D. M. Bloom, "Electrooptic Sampling in GaAs Integrated Circuits," IEEE J. Quantum Elect.22, 79-93 (1986). [6] S.Gupta,M.Y.Frankel,J.A.Valdmanis,J.F.Whitaker,G.A.Mourou, F. W. Smith and A. R. Calaw, "Subpicosecond carrier lifetime in GaAs grown by molecular beam epitaxy at low temperatures," App. Phys. Lett. 59, pp. 3276-3278 91991) [7] Ch. Fattinger, D. Grischkowsky, "Terahertz beams," Appl. Phys. Lett. 54, pp.490-492 (1989) [8] D. M. Mittleman, R. H. Jacobsen, and M. Nuss, "T-Ray Imaging," IEEE JSTQE 2, 679-698 (1996) [9] A. Bonvalet, J. Nagle, V. Berger, A. Migus, JL Martin, and M. Joffre, "Ultrafast Dynamic Control of Spin and Charge Density Oscillations in a GaAs Quantum Well," Phys. Rev. Lett. 76, 4392 (1996). 383

384 BIBLIOGRAPHY