ph Sensor Model 397 CAUTION SENSOR/PROCESS APPLICATION COMPATIBILITY WARNING ATEX DIRECTIVE Instruction Sheet PN 51A-397/rev.



Similar documents
General Purpose ph/orp Sensor

Submersion/Insertion Toroidal Sensor

General Purpose ph/orp Sensors

Sanitary and CIP Toroidal Sensor

For additional information, please visit our website at

Toroidal Conductivity Sensor

Dissolved Oxygen Sensors

Trace Dissolved Oxygen Sensor

Ozone Sensor. Model 499A OZ CAUTION CAUTION. Instruction Sheet PN 51A-499AOZ/rev.F January 2007

Submersion/Insertion Toroidal Sensor

PART 1 - INTRODUCTION...

ENDURANCE Conductivity Sensors

ph Measurement and Control

TB2CS Conductivity sensor 2-Electrode. Superior accuracy in low level conductivity measurement ranges

User Guide. ExStik TM ph (PH100 & PH110) and ORP (RE300) Waterproof Series Pens. Patent Pending

AIRMoN, ph and Conductivity Field Measurement

The Control of ph and Oxidation Reduction Potential (ORP) in Cooling Tower Applications By Charles T. Johnson, Walchem Corporation

Direct ISE Method Method to 1000 mg/l Na + Sodium ISE

Instruction Manual PN /rev.E March 2010 Model 381. ph/orp Sensor

USEPA Electrode Method Method 8156

Digital inductive conductivity transmitter

UltraBasic Benchtop ph Meter Operation Manual

The Theory of ph Measurement

Operator Quick Guide EC SENSOR

Multi-Parameter Electrochemical / Optical Water Quality System

Care and use guide. Contents. a handy solution made easy. page

SenTix 950 SenTix 980

Care, Maintenance, and Storage of YSI 6-Series Probes and Sondes

Electronic Flow Switches

Measuring ph in Water or CaCl2 Using a ph Meter. Compiled by Darren Murray, June 30, 2011 TABLE OF CONTENTS OVERVIEW 3

Recommended Procedures for Use of YSI Water Quality Monitoring Instruments during Oil Spills

WIKA INSTRUMENT CORPORATION

ExStik TM ph Waterproof Meters

OxyGuard. Dissolved Oxygen Probe

SCREAMIN' EAGLE "HEAVY BREATHER" PERFORMANCE AIR CLEANER KIT

How To Use A Cdm250 Digital Multimeter

Mobrey Ultrasonic. MSP900SH Level and MSP900FH Flow Transmitters. Product Data Sheet February 2015 IP2032, Rev BA

Select Radiators Installation Guide

BBWX1 Satellite Weather Receiver. Installation and Maintenance Guide

Models SFP33 & SFP32 Pressure Transmitters

FASCINATION 700 HVLP TANNING PRO SYSTEM USER MANUAL

USER MANUAL. 10 GPM Small Single Line Cryogenic Coupling

Milwaukee USER MANUAL

Metal Rescue Rust Remover Technical Data

Professional Plus. Calibration Tips

Block and Bleed Gauge Valves M25 and M251

Replacement parts. WM97+ gas-fired water boiler Boiler Manual. OBTAIN PARTS ONLY THROUGH WEIL-McLAIN THE BOILER CONTAINS CERAMIC FIBER MATERIALS

SCREAMIN' EAGLE "HEAVY BREATHER" PERFORMANCE AIR CLEANER KIT

Easy Tool Retracting System CMC-SR2159ER36

! WARNING. McDonnell & Miller Installation & Maintenance Instructions MM-217(I) Series 150S and 157S (Snap Switch, All Models except 157S-RB-P)

Instruction Manual LIQ-MAN-5081P/rev.J January Model 5081-P. Two-Wire ph/orp Transmitter

YSI Meter Protocol: Specific Conductivity, ph, & Dissolved Oxygen

WEL Series ph/orp ELECTRODES

RAY-MAX Integrated Solar Power Strip

A99B Series Temperature Sensors

INSTALLATION INSTRUCTION SPEC. SHEET 7/00. City of New York Calendar #40747 ETL LISTED UNDER U.L. STD LOW VOLTAGE TRACK LIGHTING SYSTEM

Owners & Installation Manual for the Sheridan, Mountainair, Pine Valley and Old Forge Ceiling Fan Family

Trunnion-Design Ball Valves

PROCEDURE COVERSHEET. Document Section: CHEMISTRY Author: JOANNE WONG Date Authored: JAN In Use Date: 2/1/2011 Discontinued Date:

6 H2O + 6 CO 2 (g) + energy

Installation and Operating Instructions Installation Instructions for SS EPE-316L Series

Global Water Instrumentation, Inc.

DISSOLVED OXYGEN PROBE

INSTALLATION INSTRUCTIONS Fan Coil Replacement Coil Kit EBX & EBXX

Hygro-Thermometer + InfraRed Thermometer Model RH101

Common Problems with Online Water Quality Analyzers. Greg Macy Director AquatiPro LLC

Phoenix Body Fat Scale Manual

Baumann 24000SB Barstock Control Valve

Fisher 1052 Size 20 Diaphragm Rotary Actuator with F and G Mounting Adaptation

Volkswagen Jetta, Golf, GTI 1999, Liter VR6 2V Engine Mechanical, Engine Code(s): AFP 17 Engine-Lubrication (Page GR-17)

Powers Controls TH 192 S Single Temperature Room Thermostat

TWO-WIRE TRANSMITTERS FOR ph, ORP, CONDUCTIVITY, OXYGEN, OZONE, AND CHLORINE

San josé OWNER S MANUAL

Float and Thermostatic Traps Series H, C and X

Sanitary Type Electronic Flow Switches

Your safety and the safety of others are very important.

81000 Series Aluminum Gate Valve Installation and Repair Manual

INSPECTION, MAINTENANCE AND RECHARGE SERVICE MANUAL P/N 16303

Powers Controls Free Energy Band TH 193 HC Heating/Cooling Room Thermostat

Milwaukee USER MANUAL. Milwaukee. Smart DO Meter PORTABLE DISSOLVED OXYGEN METER MODEL: SM600. Authorized Dealer: ISMIL600 11/01

G H I J K G DIMMING. QS no dimming 1 0. (10%) 3-wire hot dim EcoSystem (10%) digital dim U 0 Mark 7 (1% HO 5% HE) 0-10 V M 0 Mark 10 (1%) hot dim N 0

Fleetguard CS41018 SpiraTec Centrifuge Rotor Installation Instructions

In-Line Electronic Flow Switches

Instruction Manual. Image of SP-3015 & SP Important Safeguards. Automatic Dispensing Hot Water Pot with Reboil Function

CEILING CASSETTE FAN COIL UNIT

OPERATING INSTRUCTIONS

CW-4622 INSTALLATION INSTRUCTIONS CB-4622 RISER KIT TO SUIT BLACK LEVER EXPOSED VALVES & BATH/SHOWER VALVES

METHOD STATEMENT INSTALLATION OF INSULATING FLANGE KITS

INSTALLATION INSTRUCTIONS BL-8704

Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS

WaterMAG. Electromagnetic Flowmeter for Water Applications. Model MCB10A OVERVIEW APPLICATIONS FEATURES. No. SS2-MCB

Operating manual. ph 7310 ph 7310P. Printermodul. ph 7310P. ph ph meter

Nitrogen, Ammonia. Known Addition ISE Method 1 Method Minimum of 0.8 mg/l NH 3 N. Ammonia ISE. Test preparation. Instrument-specific table

Measuring the Conductivity of Pure Water Using USP<645>

Fisher 1061 Pneumatic Piston Rotary Actuator with Style F & G Mounting Adaptations

Volkswagen New Beetle 2.0 Liter 4-cyl General, Engine (Engine Code AEG) 17 Engine-Lubrication system (Page GR-17)

tire inflator with pressure gauge

Care and use guide. Contents. page

The cylinder head bolts tightening stages have been updated as listed in Table 1.

Transcription:

Instruction Sheet PN 51A-397/rev.F January 2011 Model 397 ph Sensor For additional information, please visit our website at www.emersonprocess.com/raihome/liquid/. SPECIFICATIONS MODEL 397 PERFORMANCE & PHYSICAL SPECIFICATIONS ph Range: AccuGlass: 0-14 ph Wetted Materials: glass, polypropylene, EP Interconnecting Cable: 15 ft (4.6 m), for use with remote preamplifier Temperature Rating: 0 to 100 C (32 to 176 F) Pressure Range: 100-790 kpa abs (0-100 psig) Minimum Conductivity: 75 μs/cm, nominal 100 μs/cm Weight/Shipping Weight: 0.45 kg/0.9 kg (1 lb/2 lb) Process Connections: NONE; must use Quik-Loc Kit which includes a 1 in. MNPT Process Connection QUIK-LOC KIT PHYSICAL SPECIFICATIONS Process Connections: 1-in. MNPT Wetted Materials: 316 SST, EP, PEEK Weight/Shipping Weight: 0.45 kg/0.9 kg (1 lb/2 lb) CAUTION SENSOR/PROCESS APPLICATION COMPATIBILITY The wetted sensor materials may not be compatible with process com position and operating conditions. Application compat ibility is entirely the responsibility of the user. WARNING Before removing the sensor, be absolutely certain that the process pressure is reduced to 0 psig and the process temperature is lowered to a safe level! ATEX DIRECTIVE Special Conditions for safe use 1. All ph/orp sensors have a plastic enclosure which must only be cleaned with a damp cloth to avoid the danger due to a build up of an electrostatic charge. 2. All ph/orp sensor Models are intended to be in contact with the process fluid and may not meet the 500V r.m.s. a.c. test to earth. This must be taken into consideration at installation. STORAGE 1. It is recommended that electrodes be stored in their original shipping containers until needed. 2. Do not store at temperatures below -5 C (23 F). 3. Electrodes should be stored with a protective cap containing KCl solution. 4. For overnight storage, immerse the sensor in tap water or 4 ph buffer solution. 5. A ph glass electrode has a limited shelf life of one year. ELECTRODE PREPARATION 1. Remove electrode from shipping container. 2. Remove the protective boot covering the electrode bulb. 3. Rinse away salt film with clean water, then shake the electrode so that the internal solution fills the bulb, thus removing any air trapped there. NOTE Do not allow lubricant to coat electrode bulb or reference junction. If it does, wipe it clean before installation. SENSOR INSTALLATION For sensor dimensions, see Figure 1. For recommended installation, see Figure 2 For wiring, see Figures 3-13.

MILLIMETER INCH 40039702 C NOTE: The EP gasket (see drawing #40039702) provided with the coupler should be periodically inspected. If gasket shows signs of corrosion, replacement will be necessary to ensure a proper and secure seal between the coupler and adapter. 40039704 B 40039701 C FIGURE 1. Dimensional Drawings For Model 397 in the Quik-Loc Unit 2

QUIK-LOC MOUNTING Wrap the pipe threads of the coupler with Teflon tape before placing it into the process pipe. The coupler can be connected to any 1 in. process connection and must be mounted within 80 of vertical, with the electrode facing down. Once the coupler is in place, the adapter should be positioned onto the back end of the sensor. Remove the parafilm wrapping from the two 0-rings on the sensor, grease the o-rings with the lube provided, and feed the sensor cable through the adapter. Once the adapter is slipped over the sensor s back end, the retaining ring (which is included with every 397 sensor) should be installed on the black, grooved, back end of the sensor body. The retaining ring secures the sensor into the adapter. The adapter/sensor assembly is now ready to be inserted into the coupler. With both arms of the coupler in the released position, insert the adapter/sensor assembly into the coupler. NOTE The adapter can not be inserted completely or properly unless both arms are in the fully released position (see Figure 1). Once the adapter has been properly placed in the coupler, both arms should be positioned in the locked position. NOTE The sensor may obstruct flow through smaller pipes. Once the arms of the coupler have been locked in position, use tamper-evident safety wire on the metal rings of the coupler arms to prevent unauthorized and/or untrained personnel from using the Quik-Loc unit. The Quik-Loc unit should be used only within the pressure and temperature limits stated for the Model 397 sensor. SAFETY WARNING It is recommended that a thermometer, drain valve to relieve pressure, and pressure gauge be inserted near the Quik-Loc assembly (see Figure 2). WARNING Once the Quik-Loc unit is installed the operator should wait for the process to cool to a safe temperature, use the pressure drain valve to relieve all process pressure and observe the pressure on the pressure gauge for proper removal of the sensor without spray or bodily injury. The Quik-Loc kit used with the 397 TUpH sensor is not recommended for use with hazardous, corrosive, or strong oxidizing chemicals due to a risk of spray or bodily injury. SAFETY WARNING It is the responsibility of each company using the Quik-Loc Kit/ 397 TUpH Sensor to train personnel of the injury risks associated with using a quick-release coupler that is placed in a hot or pressurized process. 40039703 B FIGURE 2. Recommended Flow-Through and Insertion Installation For Model 397 3

FIGURE 3. Model 397 Standard Wiring Option used with Models 1054A, 1054B, 2054, and Preamplifiers PN 22698-02 and 22698-03 FIGURE 4. Model 397 Option -62 for Wiring to Models 1054, 1055, 1181, 2081, 54, 54e, 81, 3081, 4081, 5081-P, Xmt-P, SoluComp, and 2700 Preamplifier (PN 23054-03). Also for use with remote Junction Box PN 23555-00. SENSOR 40039607 C FIGURE 5. Wiring to Model 1181 ph Analyzer. 4

FIGURE 6. Preparing Coax Cable for Wiring to Models 54e, 1055, 81, 2081, 3081, 4081, 5081, and Xmt. FIGURE 7. Wiring to Model 2081 FIGURE 8. Wiring to Models 54e, 81, 3081, 4081, and 5081 FIGURE 9. Wiring to Model Xmt-P-XX-10 5

FIGURE 10. Wiring to Models 1054A, 1054B, and 2054 FIGURE 11. Wiring through Junction Box PN 23309-04 (03) and Remote Preamplifier 6

FIGURE 12. Wiring to Model 1055-01-10-22-32 FIGURE 13. Wiring to Model 1055-11-22-32 through a Remote Junction Box 7

TWO POINT BUFFER CALIBRATION Select two stable buffer solutions (at least two ph units apart), preferably ph 4.0 and 10.0. NOTE A ph 7 buffer solution reads a mv value of approx. zero, and ph buffers read approximately ± 59.1 mv for each ph unit above or below ph 7. Check the ph buffer manufacturer specifications for millivolt values at various temperatures since it may affect the actual value of the buffer solution mv/ph value. 1. Immerse sensor in the first buffer solution. Allow sensor to equilibrate to the buffer temperature (to avoid errors due to temperature differences between the buffer solution and sensor temperature) and wait for reading to stabilize. Value of buffer can now be acknowledged by analyzer/transmitter. 2. Once the first buffer has been acknowledged by the analyzer/transmitter, rinse the buffer solution off of the sensor with distilled or deionized water. 3. Repeat steps 1 and 2 using the second buffer solution. 4. The theoretical slope value, according to the Nernst equation for calculating ph, is approximately 59.17 mv/ph. Over time the sensor will age, both in the process and in storage, and will result in reduced slope values. To ensure accurate readings, it is recommended that the electrode be replaced when the slope value falls below 47 to 49 mv/ph. RECOMMENDED ph SENSOR STANDARDIZATION For maximum accuracy, the sensor can be standardized on-line or with a process grab sample after a buffer calibration has been performed and the sensor has been conditioned to the process. Standardization accounts for the sensor junction potential and other interferences. Standardization will not change the sensor s slope but will simply adjust the analyzer s reading to match that of the known process ph. MAINTENANCE Electrodes should respond rapidly. Sluggishness, offsets, and erratic readings are indicators that the electrodes may need cleaning or replacement. 1. To remove oil deposit, clean the electrode with a mild non-abrasive detergent. 2. To remove scale deposits, soak electrodes for 30 to 60 minutes in a 5% hydrochloric acid solution. 3. Temperature effect on life expectancy: If glass electrode life expectancy is 100% @ 25 C (77 F), then it will be approximately 25% @ 80 C (176 F), and approximately 5% @ 120 C (248 F). The right people, the right answers, right now. ON-LINE ORDERING NOW AVAILABLE ON OUR WEB SITE http://www.raihome.com Specifications subject to change without notice. 8 Credit Cards for U.S. Purchases Only. Emerson Process Management 2400 Barranca Parkway Irvine, CA 92606 USA Tel: (949) 757-8500 Fax: (949) 474-7250 http://www.raihome.com Rosemount Analytical Inc. 2011