SIMATIC NET Industrial Ethernet switches MM900 media modules for SCALANCE XR-500M



Similar documents
Validity 1. Improvements in STEP 7 2. Improvements in WinCC 3 SIMATIC. Readme. Programming and Operating Manual

CPU PN/DP: Configuring an ET. 200S as PROFINET IO device SIMATIC. PROFINET CPU PN/DP: Configuring an ET 200S as PROFINET IO device

CompactLogix Power Supplies Specifications

Validity 1. Installation 2 SIMATIC. WinCC flexible Tag simulator Update 1. Readme

My first Hirschmann: The SPIDER family of switches.

SCALANCE X005 / X005TS SIMATIC NET. Industrial Ethernet switches SCALANCE X005 / X005TS. Introduction. Network topologies. Description of the device 3

ConneXium Ethernet Switches TCSESU0 F N0 Quick Reference Guide

MCR1900 Media Converter 19-Slot Chassis

Perle Protocol Transparent Media Converter Modules

DeltaV Control Network Hardware

M7250P. PoE Powered. Gigabit Ethernet Media Converter 1000BASE-TX TO 1000BASE-SX/LX. Installation Guide

SIMATIC. ET 200S distributed I/O Digital electronic module 8DI DC24V (6ES7131-4BF00-0AA0) Preface. Properties 1. Diagnostics 2.

EMOSAFE EN-100. Network Isolators for PCB assembly 1 GENERAL DESCRIPTION. Product Data Sheet ENGLISH

Creating the program. TIA Portal. SIMATIC Creating the program. Loading the block library. Deleting program block Main [OB1] Copying program blocks

SIMATIC. ET 200S distributed I/O 2AO I ST analog electronic module (6ES7135-4GB01-0AB0) Preface. Properties 1. Parameters 2.

HARTING econ 3000 Introduction and features

SIMATIC. ET 200S distributed I/O Digital electronic module 8DO DC24V/0.5 A (6ES7132-4BF00-0AA0) Preface. Properties 1. Diagnostics 2.

Digital input modules

HARTING mcon 1000 Introduction and features

Short-circuit current rating (SCCR) of. industrial control panels. NEC Article 409 and UL 508A

Perle 10/100/1000 Ethernet Media Converter Module

NI NI C Series Overview DATASHEET. 8-Channel Sinking Digital Input Module

RS 485 Repeater SIMATIC. RS 485 Repeater. Preface 1. Introduction. Description 3. Installation 4. Connecting. Technical data 6.

SFP+ DWDM Dual LC 10G SMF 40km Transceiver. Features. Applications APPLIED OPTOELECTRONICS, INC. A7ELXDxxEDMA0609

SIMATIC. Process Control System PCS 7 Configuration Symantec Endpoint Protection (V12.1) Preface 1. Virus scanner administration 2.

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

1756 ControlLogix Chassis Specifications

SIMATIC. PC Adapter USB. Preface, Contents Properties of the PC Adapter USB 1. Package Components

Technical Data. Dimensions

SIMATIC NET SCALANCE XR-500M A5E A-01. Compact operating instructions. English 09/2011

Technical Data. General specifications Switching element function Rated operating distance s n 15 mm

Square D Clipsal DIN-Rail Four-Channel Auxiliary Input Unit

G-TAP A Series // Data Sheet

Inductive slot sensor

PROFINET CPU 314C-2 PN/DP, PN/DP, PN/DP, PN/DP: Configuring the PROFINET interface

Full_IG.book Page 1 Monday, January 9, :11 PM. ProSafe 24 Port Gigabit Switch Installation Guide

SIMATIC NET. CP AS-Interface Master B C. Preface Contents. Technical Description and Installation Instructions Interface to the User Program

HP ProCurve High-Speed Transceivers Installation Guide

Technical Data. General specifications Switching element function Rated operating distance s n 4 mm

IFS SP-PoE Splitter User Manual

Redundancy Module QUINT-DIODE/40

SIMATIC S Getting Started for First Time Users. Order No.: 6ZB5310-0NC02-0BA0 04/2007 A5E

TX OPEN RS232/485 module

Quick Installation Guide 24-port PoE switch with 2 copper Gigabit ports and 2 Gigabit SFP ports (af Version 15.4W)

Isolating Barriers for our sensors A5S1 in Ex-areas Series D461

How To Protect Your Deltav Controllers From Cyber Attacks

SIMATIC. Programming device SIMATIC Field PG M2. Introduction. Description 2. Application Planning 3. Setting up and connecting 4. Startup 5.

Creating the project and hardware. TIA Portal. SIMATIC Creating the project and hardware. Introduction to the TIA Portal 1. Creating a project

3500/62 Process Variable Monitor

CP SIMATIC NET. S Telecontrol CP Preface. Application and properties. Displays and connectors 2

Cisco MFE and MGE SFP Transceivers Cisco Small Business Network Accessories

Industrial RS-232/ RS-422/ RS-485 over Ethernet Media Converter

Cisco TelePresence MCU 4500 Series safety and compliance information

FLUORESCENT UV- RING LIGHT OPERATING INSTRUCTION

Visualization SIMATIC. Visualization. Present sample project. HMI configuration. Insert HMI device from libraries 3. Configuring HMI connection 4

SCALANCE X-100 media converter SIMATIC NET. Industrial Ethernet switches SCALANCE X-100 media converter. Introduction 1. Network topologies

Replacing a Copper or Fiber Transceiver on a NetScaler Appliance

PT100 Portable TAP. User Guide. Revision 1.0

US Installation Manual Smappee Monitor

8-port 10/100Base-TX +2-port 100Base-FX Switch. User s Guide

Hardware Manual CAN-IB130/PCIe CAN-IB230/PCIe PCIe/104 CAN Interface

1788 Linking Device Specifications

WinCC Runtime Professional Readme SIMATIC HMI. WinCC V11 SP1. Readme WinCC Runtime Professional. Special considerations for Windows 7.

LOGO!Power. Power supply. LOGO!Power. Overview. Safety instructions. Description, device design, dimension drawing. Mounting/disassembly

LOGO!Power. Power supply. LOGO!Power. Overview. Description, device design, dimension drawing. Mounting/Disassembly 2

Foxboro Evo Process Automation System

Industrial 10/100/1000BASE-T to 100/1000BASE-X SFP Media Converter

Duct Humidity Transmitter

CISCO 10GBASE X2 MODULES

aseries A13B Mini Bullet Camera User Manual

AC 800M. EtherNet/IP DeviceNet Linking Device LD 800DN. Power and productivity for a better world TM SP1134

4-Port 10/100Mbps with PoE + 1-Port 100FX Industrial Ethernet Switch Wide Temperature

Patch management and security. updates SIMATIC. Process Control System PCS 7 Patch management and security updates. Preface 1

Powerline 1200 User Manual

FOSTCDR. Industrial Serial to Multimode Fiber Optic Converter PRODUCT INFORMATION B&B ELECTRONICS. Specifications Serial Technology

How To Write A Librao Low Voltage Differential (Lvds) Module On An Nio 6585 Fuserio (Flexrio) Power Supply (Femaleseo) And Power Supply On An Iphone Or Ip

Power Supply Guide Version 1.0 for D-Show

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT Spur 2. Spur 1. Zone 1. Zone 0

10/100/1000 Base-T to Gigabit Fiber Media Converter

SINAMICS drives SINAMICS DCM. DC converters from 6 kw to 2500 kw for variable-speed direct-current drives. Load-balanced control application

Gigabit Switching Ethernet Media Converters - Product User Guide

HMIGTO4310 advanced touchscreen panel 640 x 480 pixels VGA- 7.5" - TFT - 96 MB

HARTING mcon 3000 Introduction and features

Documentation for. KL2602 and KL2622. Two-channel Relay Output Terminals for 230 V AC / 30 V DC. Version: 1.4 Date:

USER MANUAL MODEL 2300M SERIES. OpticLink Ethernet Media Converters (2300M, 2310M, 2311M, & 2312M)

Cisco Small Form-Factor Pluggable Modules for Gigabit Ethernet Applications

Power Supplies 3. SDN-P DIN Rail Series

FOM-5A, 6A. Asynchronous Fiber Optic Modem

Cisco Unified IP Phone Power Injector

How To Power A Power Supply Shelf With A Power Unit (Hp 2920)

Technical Data. Dimensions

SECTION VIDEO SURVEILLANCE SYSTEMS INFRASTRUCTURE

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

S-series Mass Connection Solutions

5SV Residual Current Protective Devices

CompactRIO crio-9052

EZmoto V2. Product description Rev. 6 10/01/2014. EZmoto V2 Product description Rev.6 10/01/2014

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Technical Data. General specifications Switching element function PNP NO/NC Rated operating distance s n 8 mm

AXIS T81B22 DC 30W Midspan

Transcription:

SIMATIC NET Industrial Ethernet switches MM900 media modules for SCALANCE XR-500M Compact Operating Instructions Legal information Qualified Personnel The product/system described in this documentation may be operated only by personnel qualified for the specific task in accordance with the relevant documentation, in particular its warning notices and safety instructions. Qualified personnel are those who, based on their training and experience, are capable of identifying risks and avoiding potential hazards when working with these products/systems. Proper use of Siemens products Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems. The permissible ambient conditions must be complied with. The information in the relevant documentation must be observed. Siemens AG 2011-2015. All rights reserved A5E03275846-04, 11/2015 1

Warning notice system This manual contains notices you have to observe in order to ensure your personal safety, as well as to prevent damage to property. The notices referring to your personal safety are highlighted in the manual by a safety alert symbol, notices referring only to property damage have no safety alert symbol. These notices shown below are graded according to the degree of danger. DANGER indicates that death or severe personal injury will result if proper precautions are not taken. WARNING indicates that death or severe personal injury may result if proper precautions are not taken. CAUTION indicates that minor personal injury can result if proper precautions are not taken. NOTICE indicates that property damage can result if proper precautions are not taken. If more than one degree of danger is present, the warning notice representing the highest degree of danger will be used. A notice warning of injury to persons with a safety alert symbol may also include a warning relating to property damage. 2 A5E03275846-04, 11/2015

Table of contents 1 Introduction...3 2 Description...4 2.1 Type designation... 4 2.2 Product characteristics... 5 2.3 Unpacking and checking... 6 3 Installation...6 4 Technical data...9 4.1 Mechanical and electrical data... 9 4.2 Cable lengths of the MM900 media modules for SCALANCE XR-500M... 13 4.3 Other properties... 15 5 Dimension drawings... 15 6 Approvals... 17 1 Introduction Purpose of the compact operating instructions Based on the compact operating instructions, you will be able to install and connect up the MM900 media module correctly. Validity of these compact operating instructions These compact operating instructions apply to the MM900 product group of the SCALANCE X-500 product line as of product version 1. Note Additional literature When working with media modules, you should also read the compact operating instructions of the SCALANCE XR-500M product group. You will find the compact operating instructions of the SCALANCE XR-500M product group on the supplied CD. A5E03275846-04, 11/2015 3

Description 2 Description 2.1 Type designation Structure of the type designation The type designation an MM900 media module for SCALANCE X-500 consists of several parts with the following meaning: Interface CU CUC SFP Property 10/100/1000 Mbps RJ-45 port electrical. 10/100/1000 Mbps RJ-45 port electrical with securing collar. 100/1000 Mbps SFP media module. [-] 100 Mbps ST port optical, multimode fiber-optic cables, up to max. 3 km. LD 1000 Mbps SC port optical, multimode fiber-optic cables, up to max. 750 m. 100 Mbps ST port optical, single mode fiber-optic cables, up to max. 26 km. 1000 Mbps SC port optical, single mode fiber-optic cable, up to max. 10 km. PoE 10/100/1000 Mbps PoE port electrical, max. 60 W. PoEC 10/100/1000 Mbps PoE port electrical, with securing collar, max. 60 W. 4 A5E03275846-04, 11/2015

Description 2.2 Product characteristics Media modules Type Properties Article number MM991-4 MM991-4LD MM992-4 MM992-4LD 4 x 100 Mbps, ST ports optical, multimode fiber-optic cable, up to max. 5 km. 4 x 100 Mbps, ST ports optical, single mode fiber-optic cable, up to max. 26 km. 4 x 1000 Mbps, SC ports optical, multimode FO cable, up to max. 750 m. 4 x 1000 Mbps, SC ports optical, single mode FO cable, up to max. 10 km. 6GK5 991-4AB00-8AA0 6GK5 991-4AC00-8AA0 6GK5 992-4AL00-8AA0 6GK5 992-4AM00-8AA0 MM992-4SFP 4 x 100 / 1000 Mbps, SFP media module 6GK5 992-4AS00-8AA0 MM992-4CU MM992-4CUC MM992-4PoE MM992-4PoEC Components of the product 4 x 10/100/1000 Mbps, RJ-45 ports electrical 4 x 10/100/1000 Mbps, RJ-45 ports electrical with securing collars 4 x 10/100/1000 Mbps, PoE ports electrical, max 60 W 4 x 10/100/1000 Mbps, PoE ports electrical with securing collars, max 60 W The following components are supplied with an MM900 media module: MM900 media module Compact operating instructions 6GK5 992-4SA00-8AA0 6GK5 992-4GA00-8AA0 6GK5 992-4QA00-8AA0 6GK5 992-4RA00-8AA0 A5E03275846-04, 11/2015 5

Installation 2.3 Unpacking and checking WARNING Do not use any parts that show evidence of damage If you use damaged parts, there is no guarantee that the device will function according to the specification. If you use damaged parts, this can lead to the following problems: Injury to persons Loss of the approvals Violation of the EMC regulations Use only undamaged parts. 1. Make sure that the package is complete. 2. Check all the parts for transport damage. If the consignment is incomplete or if there is damage to the exterior, contact your supplier or your local Siemens office. 3 Installation NOTICE Failure of the data traffic due to contamination of optical plug-in connections Optical sockets and plugs are sensitive to contamination of the end face. Contamination can lead to the failure of the optical transmission network. Close unused optical sockets and plugs as well as pluggable transceivers and slots with the supplied protective caps. Remove the protective caps only immediately before you use the plug-in connection. NOTICE Use only approved media modules In the module slots of SCALANCE XR500, use only approved media modules "MM900" of the X-500 IE switch product line. 6 A5E03275846-04, 11/2015

Installation Note Slots for PoE modules PoE modules can only be used in slots1, 2 and 3. Note The names and labeling of the media modules differ Example: The device is called, for example MM992-4SFP [6GK5 992-4AS00-8AA0], the labeling on the device is 9924AS. Note Factory settings of the media modules When inserting a media module, the parameters of the ports are set to the factory defaults. First plug a media module into the device, and then assign the parameters for the ports. Identification of the media module slots and ports The following table shows the arrangement of the slots and ports of a SCALANCE XR552-12M: Slot 1 2 3 Port P1 P2 P3 P4 P1 P2 P3 P4 P1 P2 P3 P4 Slot 4 5 6 Port P1 P2 P3 P4 P1 P2 P3 P4 P1 P2 P3 P4 Slot 0, P1 P2 P3 P4 port (SFP+) Slot 7 8 9 Port P1 P2 P3 P4 P1 P2 P3 P4 P1 P2 P3 P4 Slot 10 11 12 Port P1 P2 P3 P4 P1 P2 P3 P4 P1 P2 P3 P4 With a SCALANCE XR528-6M, there are total of six slots and four SFP+ ports. Note Slot number In modular devices, the MM900 media modules can be assigned a slot number to aid orientation. The slot number labels ship with the modular devices. A5E03275846-04, 11/2015 7

Installation Plugging in media module Figure 3-1 Plugging a media module into a SCALANCE XR552-12M. SCALANCE XR528-6M is used analogously. Follow the steps below to plug an MM900 media module into a SCALANCE XR500: 1. Remove the dummy covers of the device slot into which you want to insert a media module. 2. Pull the handle out of the media module. The media module cannot be installed unless the handle is pulled out. 3. Place the media module in the guide rails of the device slot. The media module is correctly installed when it locks easily into the device and the front panel of the module is flush with the front of the device. 4. Push the handle back into the module. The media module is then locked in place. 8 A5E03275846-04, 11/2015

Technical data Pulling a media module To pull a media module, follow the same steps as when plugging, but in the reverse order: 1. Pull out the handle of the media module. 2. Pull the media module out of the device slot. 3. Close the device slot with a dummy cover if you are not plugging in another module. NOTICE Operating the device only with closed module slots The device meets degree of protection IP20, if all the module slots have either media modules inserted or are closed by dummy covers. Do not start up the device with open module slots since the ingress of objects can lead to damage. 4 Technical data 4.1 Mechanical and electrical data Device variants The following technical specifications apply to the following device: MM900 media module for SCALANCE XR-500M Note Degree of protection of the media modules Note that the media modules do not have a degree of protection. The degree of protection is only relevant for the basic devices. A5E03275846-04, 11/2015 9

Technical data Interfaces Media module MM992-4CU MM992-4CUC MM992-4SFP Interfaces 4 x 10/100/1000 Mbps, RJ-45 ports electrical. 4 x 10/100/1000 Mbps, RJ-45 ports electrical with securing collar. 4 x 100/1000 Mbps, SFP media module. MM992-4PoE 4 x 10/100/1000 Mbps, PoE ports electrical, max 60 W. MM992-4PoEC MM991-4 MM991-4LD MM992-4 MM992-4LD Construction 4 x 10/100/1000 Mbps, PoE ports electrical, with securing collar, max 60 W. 4 x 100 Mbps, ST ports optical, multimode fiber-optic cable, up to max. 5 km. 4 x 100 Mbps, ST ports optical, single mode fiber-optic cable, up to max. 26 km. 4 x 1000 Mbps, SC ports optical, multimode FO cable, up to max. 750 m. 4 x 1000 Mbps, SC ports optical, single mode FO cable, up to max. 10 km. Media module Dimensions and weight Value MM992-4CU MM992-4CUC MM992-4SFP MM991-4 MM991-4LD MM992-4 MM992-4LD MM992-4PoE MM992-4PoEC Dimensions (W x H x D) Weight Dimensions (W x H x D) Weight 120 x 22 x 305 mm 300 g 120 x 22 x 305 mm 387 g 10 A5E03275846-04, 11/2015

Technical data Permitted ambient conditions Environmental conditions Transportation/storage temperature -40 to +70 C Operating temperature 0 to +60 C Maximum relative humidity in operation at 25 C Operating altitude above sea level depending on ambient temperature < 95 % no condensation 2000 m at max. 56 C 3000 m at max. 50 C Electrical data Media module Current consumption* Maximum power consumption* MM992-4CU 0.14 A 3.36 W MM992-4CUC MM992-4SFP 0.02 A 0.48 W MM992-4PoE MM992-4PoEC 2.89 A (at 60 W PoE load) MM991-4 0.20 A 4.8 W MM991-4LD 0.16 A 3.84 W MM992-4 0.13 A 3.12 W MM992-4LD 0.15 A 3.6 W * At 24 VDC rated voltage of the basic device 69.36 W (at 60 W PoE load) Note Fusing and signal contacts with media modules The MM900 media modules do not have their own fuses and have no signaling contacts. The fuses and the signaling contacts exist in the SCALANCE device. A5E03275846-04, 11/2015 11

Technical data Electrical data: Transmitter output (optical) and receiver input Media module Transmitter output (optical) Receiver input min. [dbm] max. [dbm] Sensitivity min. [dbm] Input power max. [dbm] MM992-4CU - - - - MM992-4CUC - - - - MM992-4SFP - - - - MM992-4PoE - - - - MM992-4PoEC - - - - MM991-4 -19-14 -32-3 MM991-4LD -15-8 -34-3 MM992-4 -9.5-4 -17-3 MM992-4LD -9.5-3 -21-3 Electrical data: Galvanic isolation with PoE modules Media module MM992-4PoE MM992-4PoEC Electrical isolation Between ports P1 to P4 Between ports and ground Between ports and power input No Yes Yes 12 A5E03275846-04, 11/2015

Technical data 4.2 Cable lengths of the MM900 media modules for SCALANCE XR-500M Permitted cable lengths (copper cable) Media module Property Lead Permitted cable length MM992-4CU MM992-4CUC MM992-4PoE MM992-4PoEC 4 x 10/100/1000 Mbps, RJ-45 ports electrical with and without securing collar IE TP torsion cable with IE FC Outlet RJ-45 + 10 m TP cord IE TP torsion cable with IE FC RJ-45 Plug 180 IE FC TP marine/trailing/flexible cable with IE FC Outlet RJ-45 + 10 m TP cord IE FC TP marine/trailing/flexible cable with IE FC RJ-45 Plug 180 IE FC TP standard cable with IE FC Outlet RJ-45 + 10 m TP cord IE FC TP standard cable with IE FC RJ-45 plug 180 0... 45 m + 10 m TP cord 0... 55 m 0... 75 m + 10 m TP cord 0... 85 m 0... 90 m + 10 m TP cord 0... 100 m A5E03275846-04, 11/2015 13

Technical data Permitted cable lengths (fiber-optic cable) for the SFP media module Media module Property Max. permittted cable length MM992-4SFP 4 x 100/1000 Mbps, SFP media module Permitted cable lengths (fiber-optic cable - Fast Ethernet) Depending on the SFP transceiver used Media module Property Fiber FO cable lengths MM991-4 MM991-4LD 4 x 100 Mbps, BFOC ports optical, multimode glass, up to max. 5 km 4 x 100 Mbps, BFOC ports optical, single mode glass, up to max. 26 km 50/125 µm multimode fiber 9/125 µm single mode fiber 0-5 km (1 db/km at 1310 nm; 1200 MHz*km) 0-26 km (0.5 db/km at 1310 nm) Permitted cable lengths (fiber-optic cable - gigabit Ethernet) Media module Property Fiber FO cable lengths MM992-4 4 x 1000 Mbps, SC ports optical, multimode glass, up to max. 750 m 62.5/125 µm multimode fiber 0-350 m (3.1 db/km at 850 nm; 1200 MHz*km) MM992-4LD 4 x 1000 Mbps, SC ports optical, single mode glass, up to max. 10 km 50/125 µm multimode fiber 9/125 µm single mode fiber 0-750 m (2.5 db/km at 850 nm; 1200 MHz*km) 0-10 km (0.5 db/km at 1310 nm) 14 A5E03275846-04, 11/2015

Dimension drawings 4.3 Other properties Table 4-1 Mean time between failure (MTBF) Device version (power supply) MM992-4CU MM992-4CUC MM991-4, MM991-4LD MM992-4LD MM992-4 MTBF > 200 years > 90 years > 70 years > 75 years > 85 years MM992-4SFP > 170 years 1) MM992-4PoE MM992-4PoEC 1) empty > 75 years 5 Dimension drawings A5E03275846-04, 11/2015 15

Dimension drawings View from the front, top, and side (right) Dimensions are specified in mm. 16 A5E03275846-04, 11/2015

6 Approvals The SIMATIC NET products described in these Operating Instructions have the approvals listed below. Note Note that the media modules meet the requirements of the approvals only in combination with the devices. Note The specified approvals apply only when the corresponding mark is printed on the product. EC directives SIMATIC NET products meet the requirements and aims of the following EC directives. EMC directive (electromagnetic compatibility) The SIMATIC NET products described in these operating instructions meet the requirements of EC directive 2004/108/EC "Electromagnetic Compatibility" for the following areas of application: Field of application Requirements Emission Immunity to interference Industry EN 61000-6-4 : 2007 EN 61000-6-2 : 2005 C-TICK The product meets the requirements of the AS/NZS 2064 standard (Class A). WARNING Personal injury and property damage can occur The installation of expansions that are not approved for SIMATIC NET products or their target systems may violate the requirements and regulations for safety and electromagnetic compatibility. Only use expansions that are approved for the system. A5E03275846-04, 11/2015 17

Approvals Keep to the installation guidelines The product meets the requirements if you adhere to the installation and safety instructions contained in this documentation and in the following documentation when installing and operating the product. You can always find the latest documentation on the Internet The current descriptions of the currently available products can always be found on the Internet under the specified entry IDs/Internet pages: SIMATIC NET Industrial Ethernet Network manual ID = 27069465 (http://support.automation.siemens.com/ww/view/en/27069465) EMC Installation Guideline, Planning Guide ID = 28518276 (http://support.automation.siemens.com/ww/view/en/28518276) Working on the product To protect the product from electrostatic discharge, personnel must first discharge any electrostatic charge from their body before touching the product. Note The product was tested with a device that also complies with the standards listed above. If the product is operated with a device that does not meet these standards, there is no guarantee that the corresponding values will be adhered to. 18 A5E03275846-04, 11/2015

Approvals ATEX (explosion protection directive) WARNING When using SIMATIC NET products in hazardous area zone 2, make absolutely sure that the associated conditions in the following document are adhered to: "SIMATIC NET Product Information Use of subasseblies/modules in a Zone 2 Hazardous Area". You will find this document on the data medium that ships with some devices. on the Internet pages of Siemens Industry Online Support. Enter the document identification number C234 as the search term. SIMATIC NET products meet the requirements of the EC directive:94/9/ec "Equipment and Protective Devices for Use in Potentially Explosive Atmospheres". ATEX classification: II 3 G Ex na IIC T4 Gc KEMA 07ATEX0145 X The products meet the requirements of the following standards: EN 60079-15 (electrical apparatus for potentially explosive atmospheres; Type of protection "n") EN 60079-0 (Explosive atmospheres - Part 0: Equipment - General requirements) You will find the current versions of the standards in the currently valid ATEX certificates. FM The product meets the requirements of the standards: Factory Mutual Approval Standard Class Number 3611 FM Hazardous (Classified) Location Electrical Equipment: Non Incendive / Class I / Division 2 / Groups A,B,C,D / T4 and Non Incendive / Class I / Zone 2 / Group IIC / T4 A5E03275846-04, 11/2015 19

Approvals culus Approval for Information Technology Equipment culus Listed I. T. E. Underwriters Laboratories Inc. complying with UL 60950-1 (Information Technology Equipment) CSA C22.2 No. 60950-1-03 culus Approval Hazardous Location culus Listed I. T. E. FOR HAZ. LOC. Underwriters Laboratories Inc. complying with UL 60950-1 (Information Technology Equipment) ANSI/ISA 12.12.01-2007 CSA C22.2 No. 213-M1987 Approved for use in Cl. 1, Div. 2, GP A, B, C, D T4 Cl. 1, Zone 2, GP IIC T4 Report no. E240480 EU declaration of conformity You will find EC declaration of conformity for these products on the Internet pages of Siemens Industry Online Support. See also ID = 57026840 (http://support.automation.siemens.com/ww/view/en/57026840) http://support.automation.siemens.com/ww/view/en/67218133 (http://support.automation.siemens.com/ww/view/en/67218133) 20 A5E03275846-04, 11/2015

Approvals The following MM900 media modules meet the FDA and IEC requirements listed below: Media module Fulfills FDA and IEC requirements MM992-4CUC - MM992-4CU - MM992-4SFP - MM992-4PoE - MM992-4PoEC - MM991-4 CLASS 1 LED PRODUCT MM991-4LD CLASS 1 LASER MM992-4 CLASS 1 LASER MM992-4LD CLASS 1 LASER Figure 6-1 FDA and IEC approvals Trademarks All names identified by are registered trademarks of Siemens AG. The remaining trademarks in this publication may be trademarks whose use by third parties for their own purposes could violate the rights of the owner. Disclaimer of Liability We have reviewed the contents of this publication to ensure consistency with the hardware and software described. Since variance cannot be precluded entirely, we cannot guarantee full consistency. However, the information in this publication is reviewed regularly and any necessary corrections are included in subsequent editions. Siemens AG Division Process Industries and Drives Postfach 48 48 90026 NÜRNBERG A5E03275846-04, 11/2015 21