Tri-MEC Ring Main Units



Similar documents
GIS. Gas Insulated Switchgear

New micro size drive of LS Industrial Systems STARVERT

High Torque Performance and Precise Control

SF6 Gas Insulated Ring Main Unit RMU. A Compact switchgear solution for secondary power distribution networks. Super Solution.

SF 6 Gas Insulated Switchgear Type SDF for 170 kv

2a. IEM Indoor Metal Clad Medium Voltage Switchgear 15KV a. Section INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std.

Dead Tank Circuit Breaker 72PM40-C Proven reliability through common platforms

Secondary Unit Substations

25-kV Apparatus Bushings B Series (bolt-in) for Elbow to Air-Insulated Service 200 Amp, 600 Amp and 1250 Amp

PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES

CAS 36 Ring Main Unit

METAL-CLAD AND METAL-ENCLOSED SWITCHGEAR 3.6KV~40.5KV. tgood.com. Energy. Fast.

MEDIUM AND HIGH VOLTAGE CAPACITORS, CAPACITOR BANKS AND SYSTEMS

Medium Voltage (MV) & High Voltage (HV) Training Module 6. Date of the presentation

Unified requirements for systems with voltages above 1 kv up to 15 kv

a Nexans company Catalogue 2013

Voltage Regulator SPAU 341 C. Product Guide

Primary and Secondary Electrical Distribution Systems

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...

DRM75A 230V 20/100A DIN rail single phase two wire energy meter

High Voltage Circuit Breakers 3AP Type 72.5 kv to 800 kv Answers for energy.

Medium voltage indoor circuit breakers ANSI/IEC solutions

Trade of Electrician. Three-phase Distribution Boards And Socket Circuits

PRODUCT GUIDE. SL Medium Voltage IEC Vacuum Contactors

Protection from Short-circuit

ELECTRICAL INSULATION TESTING OF HV EQUIPMENT UP TO 33kV

MEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV

a Nexans company Catalogue 2014

Pressure monitoring equipment for oil-sf 6. bushings, type GOEK

MV, HV AND EHV SWITCHGEAR TESTING & COMMISSIONING

Fundamentals of Modern Electrical Substations Part 1: Mission of Electrical Substations and their Main Components

UniGear ZS1. Medium voltage, arc proof, air insulated switchgear for primary distribution

Submit shop drawings for equipment provided under this section Shop drawings shall indicate:

CEF 9 CEF-S 23 CEF-VT 27 CMF 31 WBP 39 WBT 47 BPS 61

NATUS NES / NES-H Draw-out Type Medium Voltage Switchgear Systems. Safe energy distribution that meets the highest industrial requirements

Vacuum Circuit Breaker CESI, KERI, CCC, ISO 9001, ISO 14001

Medium Voltage Products. ZN1 12 kv arc-proof air-insulated switchgear for primary distribution

UFES Active protection for switchgear

5SV Residual Current Protective Devices

Guide to the electrical parameter classifications of IEC and IEC safety standards

Circulating Current Relay. Type IRXm

ALTERNATIVE METHODS FOR INTERNAL ARC TESTS ON 12 KV AND 24 KV METAL-ENCLOSED SWITCHGEARS WITH COMPACT RMU

Low voltage Direct Current Network. Compact NSX DC PV. Circuit breakers and switch disconnectors for solar application.

3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & Instructions For Installation, Operation & Maintenance

Arc Terminator Active Arc-Resistant Switchgear

HP UPS R1500 Generation 3

Outdoor circuit breaker GVR Recloser Hawker Siddeley Switchgear. rated voltage 15, 27 and 38 kv rated current 630 A

ADM1TE 5/30A DIN rail single phase two wire energy meter

Aerial Fibre Optics. Complete One Stop Solution for Aerial Fibre Optics. OPGW Cable and Fittings for OPGW

MDT5N25 & MTD5N40 SERVICE PARTS

3.0 CHARACTERISTICS. AR Auxiliary Relay High Speed, High Threshold C

Fusible Disconnect Switch

Fundamentals of Power

RAY-MAX Integrated Solar Power Strip

Low Voltage Products. Switches Automatic Transfer Switches

Table of Contents. TransformerIQ FAQs 1

R.C.C.B. s two-pole LEXIC

Medium voltage products. Fuses

ABB ! CAUTION. Type COQ Negative Sequence Generator Relay. (50/60 Hertz) J. Instruction Leaflet

The Intelligent AX1 Switchgear for Medium Voltage

HVL 5 38 kv Load Interrupter Switchgear. The Standard for Performance, Protection and Dependability

Transformer Bushings for GIS

Metal Clad Indoor Instrument Transformer for Plug-In Systems

Section 21. Telecommunication Hardware. BuyLog Catalog 21-1

PowerFlex 700S and 700H Frame 12 DC Bus Connector Kit

TRANSFORMER DICTIONARY

T Substation Maintenance and Commissioning Test Equipment

RM4TG20 three-phase network control relay RM4-T - range V

Product overview brochure. ABB Medium Voltage Products Our one-stop approach for every medium voltage application

ABB Fuses Competitive Advantages

DANGER DANGER. General Information. Safety Is Your Responsibility. Ordering Parts. Contact Information

Molded Case Circuit Breaker Specifications Bulletin Number 140U-D

This section applies to the design and installation of transformers.

1ZSE en, Rev. 8. Transformer bushings, type GOE and GOE(2) Technical guide

Single-phase ( V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable

Trip circuit supervision relay. Type RXTCS

Voltage Rated operating voltage [kv] Rated power frequency withstand voltage [kv] Rated lightning impulse withstand voltage [kv]

MiCAFIL. 1 RIP Technology. Bushings. Z. Zic 09/2003

Cable Accessories. for Extruded Dielectric Cable 69kV - 230kV Rated. Catalog Python13

ELECTRIC METERING COMMERCIAL & INDUSTRIAL

CAT ATC POWER BREAKER & POWER CASE SWITCH AUTOMATIC TRANSFER SWITCH

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

High-Voltage Compact Switchgear 3AP1 DTC for 145 kv and 245 kv

How To Build A Low Voltage Capacitor Lvcp

Vario-Series Accessories

ANCILLARY EQUIPMENT AND ELECTRICAL EQUIPMENT Power Supply Systems and Electrical Equipment for Desalination Plants - Y.M. Hamud and A.H.

Oil and Coolant Circulating Heating System. Model - OCSM

Takfan Machinery and Mould Co Ltd. Plug in Bushing. LV Monoblock. RMU Bushing. 4 Way CT Terminal.

Current Limiting Protector For Systems rated kV and continuous currents through 5000A.

Lightning Arresters P KVA P KVA. Description & Installation

Modular Systems, PPMV, 2014 UniPack-G Glass Fiber Reinforced Polyester Compact Secondary Substation

Model 1756 Test Lead Kit

User s Manual Before using the inverter, you need to read and save the safety instructions.

12-Volt Negative Ground Installation Instructions

LOW VOLTAGE RING TYPE MEASURING CURRENT TRANSFORMERS

Modular Systems wind portfolio overview Power Collection and Grid Connection products

MEDIUM VOLTAGE SWITCHGEAR CATALOGUE. Code: P2490_xx

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

Testing Accessories. Test PaddleS. Insulated Socket Wrench Jumper Strips Test Lead Kit. Test Paddle Attachment Clips Plugs Binding Posts

ELEKTROTEHNI KO PODJETJE Leskoπkova cesta 12, 1000 Ljubljana, SLOVENIA

Transcription:

Leader in Electrics & Automation Tri-MEC Ring Main Units Medium Voltage Secondary Distribution Ring Main Units Up to 24kV, SF6-Insulated Electric Equipment

Ring Main Units Technology Safety Durability and usefulness Saving Cost

CONTENTS: Applications 4 Features 5 Configurations 6 Medium Voltage Secondary Distribution Ring Main Units Up to 24kV, SF6-Insulated Modules 8 Ring switch module (RPL) 8 Fuse-switch module (RPF) 9 Circuit breaker module (RVB) 10 Outer assembly 11 RPS 11 RPF 12 RPL 13 RVB 14 RBR 15 Cable termination 16 Ring switch / Circuit breaker 16 Fuse-switch 16 Pannel connection 18 Accessories 19 Installation 24 Technical data 25 Quality assurance 26

Ring Main Units Applications Tri-MEC Tri-MEC is designed for use in the following applications: Compact secondary substations Small industries Wind power plants Hotels, shopping centers, office buildings, business centers etc. Light mining applications, airports, hospitals, tunnels and underground railways Generation Transmission Distribution(24kV) Transmission line Substation Commercial & Industrial customers Power plant Note) Application range. 4

Features Technology Metal enclosed unit for indoor installation and type tested. Insulated by SF6 Gas Independent of climate. ON-OFF-EARTH, three position load break switch. Safety Approachable and operable safely in the presence of power in the cables. Clear indication of operation status via mimic diagram on front panel. Fully automatic interlocking system. Voltage detector to check the presence of voltage in the cable. Durability and usefulness Metal enclosed tank is hermetically sealed, it means this is independent of environmental effects such as dirt, small insects, and moisture and so on. Load break switch operating is possible in the front of Ring Main Units. All switching operations can be made safely to personnel because of interlocking system that operates automatically according to the switch position by the operator. Remote operation available in case of using motor mechanism. Fuse LBS will be tripped by a fuse striker pin connected to the mechanism in the event of fault happening. Individual panels and panel blocks can be freely combined and extended. Saving cost Only a little maintenance is required except replacement of HRC Power fuse after installation. Compact design that requires minimum space to install and operate locally is main advantage especially where the space is limited. Materials can be recycled after the end of its service life. 5

Ring Main Units Configurations General Tri-MEC RMU is an extensible and non-extensible ring main unit for the secondary distribution network. Tri-MEC RMU can be supplied in various different configurations suitable for most switching applications in 24 kv distribution networks. When combined with the Tri-MEC RMU, they represent a complete solution for 24kV secondary distribution networks. Tri-MEC RMU is a completely sealed system with a stainless steel tank, gas tight metal enclosure, containing all the live parts, Switching-disconnector, earth switch, Fuse switch, the circuit breaker. A sealed steel tank filled with SF6 gas ensures a high level of reliability as well as safety and a maintenance-free system. The Tri-MEC RMU offers the user a choice of either a switchdisconnector combined with fuse or circuit breaker with relay for protection of the transformer. Tri-MEC RMU can be controlled completely with an feeder remote unit. Most of this switchgear exists in version that are extensible on the right or on both sides, in order to provide for future development. Information of model name R P: Puffer V :V.I B: Bus D: Double feeder U: Upside down RMU L: LBS F: Fuse B: Breaker R: Rising S: Standard Non-Extensible type RPS <2 LBS + 1 Fused LBS> LBS LBS LBS VD Fuse VD 1535 1502 706 RPF(1R1F) <1 Fused LBS + Bus rising> Weight: 400kg * S LBS Fuse VD 695 1537 SA * 1061 706 880 6 Note) *: Option Weight: 275kg

Configurations Extensible type RPL <LBS Panel> LBS VD 1750 456 730 Weight: 210kg RPF <Fused switch Panel> * S LBS 1750 Fuse 683 611 730 765 Weight: 275kg RVB <Circuit Breaker Panel> VCB Trip 2 CT OC * 1750 520 730 Weight: 260kg RBR <Bus Rising Panel> 1750 VD 683 456 730 765 Weight: 160kg Note) *: Option 7

Ring Main Units Modules Ring switch module (RPL) LBS VD < ON position > < OFF position > < EARTH position > EARTHING SWITCH LOAD BREAK SWITCH EARTHING SWITCH LOAD BREAK SWITCH EARTHING SWITCH LOAD BREAK SWITCH Open Open Open Open Open Open Earth Close Earth Close Earth Close Feature Three position load break switch and earthing switch. Indicator of switch position for load break switch and earthing switch. Voltage indicator lamp on panel makes it possible to check the presence of voltage in the cables. Pressure gage indicates status of SF6 gas tank and make it check leakage of gas. Intelligent interlock system : To switch to Earth position, it should pass "OFF" position from "ON" position Applied high-speed rotary puffer type for extinction of arc. Dead front structure: It prevents an accident of touching because the live part is not exposed. Electrical (Remote/Local)operation : operated by controller which can communicate with FRU (Feeder Remote Unit) Busbars, 630A 8

Fuse-switch module (RPF) * S B A LBS Fuse C Note) *: Option < ON position > A < OFF position > < EARTH position > B B C Close Open Close Open Close Open FUSE SWTICH FUSE SWTICH FUSE SWTICH Open Earth Open Earth Open Earth EARTHING SWITCH EARTHING SWITCH EARTHING SWITCH Feature Fuse rating: 24kV, Max 63A HRC power fuse Indicator of switch position for load break switch and earthing switch The Fuses conforming to DIN 43625 are used. Automatically tripped to protect from fault current when a fuse is blown Applied high-speed rotary puffer type for extinction of arc. Dead front structure: It prevents an accident of touching because the live part is not exposed. Busbars 200A Option: CTD (Condensor Trip Device) 9

Ring Main Units Modules Circuit breaker module (RVB) VCB Trip 2 CT OC * Note) *: Option < ON position > < OFF position > < Spring charge indicator > Mechanism operation time Feature 200A vacuum circuit breaker Rated breaking time: 3cycle Latched mechanism - close and open coil Protection as specified by customers Motor charge type and Manual charge type Option:CTD(Capacitor Trip Device), OCR 10

Outer assembly(non-extensible) RPS (2LBS + 1Fuse-switch) 18 ❽ ❾ ❶ ❷ ❿ ❸ 11 ❹ 12 ❺ 13 ❻ 14 15 ❼ 16 17 ❶ LBS operation part ❼ Cable clamp 13 Fuse strike link LBS LBS LBS ❷ Chamber ❸ Control connector ❽ Nameplate ❾ Gas pressure gauge 14 200A bushing 15 Straight connector VD Fuse VD ❹ Fixing bolt for cover ❿ Voltage detector 16 Earth lug ❺ 630A bushing 11 Fuse holder Body 17 Earth busbar ❻ Elbow connector 12 Fuse holder cap 18 Lift lug 11

Ring Main Units Outer assembly(extensible) RPF (Fuse-switch) 19 ❶ ❼ 14 ❺ ❷ 15 ❿ ❾ 16 17 ❸ 12 ❹ 13 11 ❽ ❻ 18 ❶ 630A bushing for connector ❽ Earth connection hole 15 Pressure switch(option) S LBS ❷ Chamber ❸ Fuse holder body ❾ Gas pressure gauge ❿ Control connector 16 Nameplate 17 Fixing bolt for cover Fuse ❹ 200A bushing ❺ Operating mechanism 11 Cable clamp 12 Fuse holder cap 18 Earthing busbar 19 Lift lug ❻ Straight connector(option) 13 Fuse strike link ❼ Upper side cover 14 CTD(option) 12

RPL (Ring switch) 14 ❶ ❼ 11 ❸ ❾ ❽ ❿ ❷ ❹ 12 ❻ ❺ 13 ❶ 630A bushing for connector ❻ Earth connection Hole 11 Gas pressure gauge LBS ❷ 600A bushing ❸ Chamber ❼ Upper side cover ❽ Operation mechanism 12 Fixing bolt for cover 13 Earthing busbar VD ❹ Elbow connection (option) ❺ Cable clamp ❾ Nameplate ❿ Voltage detector 14 Lift lug 13

Ring Main Units Outer assembly(extensible) RVB (Circuit breaker) ❶ ❼ ❽ ❾ ❻ ❸ 12 11 ❹ ❷ ❺ ❿ 13 ❶ 630A bushing for connector ❻ Gas pressure switch (Option) 11 Voltage detector VCB Trip ❷ 630A bushing ❸ Chamber ❼ Upper side cover ❽ Operation mechanism 12 Gas pressure gauge 13 CT 2 CT OC * ❹ Elbow connection (Option) ❺ Cable clamp ❾ Gas filling valve ❿ Nameplate Note) *: Option 14

RBR (Bus rising) 12 ❻ ❶ ❽ ❼ ❸ 11 ❷ ❾ ❹ ❺ ❿ ❶ 630A bushing for connector ❷ 630A bushing ❸ Chamber ❹ Elbow connection (Option) ❺ Earthing busbar ❻ Upper side cover ❼ Gas pressure gauge ❽ Nameplate ❾ Voltage detector ❿ Cable clamp 11 Fixing bolt for cover 12 Lift lug VD 15

Ring Main Units Cable termination Ring switch / Circuit breaker (ANSI/IEEE Std. 386) These connectors are designed for easy installation on extruded shield cable or metallic tape shielded cab. The connector range is from 1/0 to 1000 kcmil for aluminum and copper conductors with insulation diam from o.640" to 1.935". ❻ ❼ ❿ ❸ ❽ ❾ ❺ ❹ ❶ ❶ Stress relief adapter Molded rubber adapter is sized to the cable insulation and provides stress relief for the terminated shield. The radial pressure exerted on the cable shield by the stress surface. Suitable for installation on both extruded-surface. Suitable for installation on both extruded-shield cable and tape-type shield cable. ❷ Spade terminal Semi-permanent, crimped-bolted connector sized for the specific conductor. Crimped on with standard tools and dies, Also used in the 650Y splice. ❸ Molded conductive shield Outer jacket of 1/8 think molded conduction peroxidecured EPDM provides a virtually in destructible ground shield for true dead-front construction. A patented ELASTI- MOLD feature. ❹ Grounding eye Hole provides a convenient point to connect a ground wire to the molded conduction shield, placing the molded shield at ground potential. ❺ Wrap-around conductive inserts Inner shield of molded conductive peroxide-cured EPDM precludes subjecting entrapped air to electrical stress. A patented ELASTIMOLD feature. ❻ Voltage test point cap Molded conduction rubber cap fits over the test point and onto the connector housing. ❼ Voltage test point The 1 hex nut located on the top of the insulation plug allows the circuit to be tested without disturbing the connection. The nut is fully insulated from the conductor and pick up capacitance voltage. A torque wrench with a 1 hex socket attachment is required during installation. ❽ Interference fit Molded insulating peroxide-cured EPDM exerts uniform con-centric-pressure on insulation of mating parts to provide required creep-path length and watermeal. ❾ Apparatus bushing Epoxy product normally supplied on manufacturers equipment. Can be welded or clamped to the apparatus. ❿ Threaded stud A removable threaded stud is included with every 655LR and K655LR. Fuse-switch The straight receptacles are fully-shield, fully-submersible and separable insulated connectors. These will accommodate conductor sizes of No. 4 solid through 4/0 stranded and cable insulation diameters from 0.495" through 0.985". Conductor contact Molded conductive insert Bushing for load side Bail tip Wire Straight receptacle housing "A" Cable Grounding eye Straight receptacle Bail Bail plate Nut 16

Cable termination 1 way 1 way with SA 2 way 2 way with SA 24kV cable termination selection table Company Voltage class Current Description Model number K655BLR Power distribution K655BIP Elastmold 600A 24kV connectors K650CP (PYUNGIL Co., Ltd) K650ETP 200A Straight receptacles K151SR EUROMOLD 24kV 600A Tee connector K400TE 5815-S 5815-T 3M 24kV 600A Modular splicing kit 5815-D 5815-E 5815-B DT625, 635 Cooper power DIP625AS, 635AS 24kV 600A Bol-T connector system CC6A-U CA625, 635 *SA: Surge Arrestor 17

Ring Main Units Pannel connection Electrical connection with special connectors Plug Clamping bolt Washer Spacer Cross connector End connector Mold cable Bushing Mechanical Joint Panel to Panel 18

Accessaries Fuse Features 1. The LS HRC Power Fuses belong to the PRIME MEC series. It interrupts high currents before the peak value and therefore cuts down the required withstand capacity of the associated equipment on the electric system. 2. Though small in size, it has a high breaking capacity and its enclosed type is suitable for use inside of the panel board. 3. PRIME-MEC fuses are equipped with striker pins for trip indicators as well as for inflicting impulse to trip link of related load break switches. Selection of fuses: According to IEC 60787(24kV) Power Fuse rated current(a) Transformer rating capacity (kva) 5 36-75 10 75-157 20 172-358 30 258-538 40 464-965 50 598-1246 63 745-1554 Note) Please ask fuse maker for optimum selection of fuses. Power fuse characteristic curve 1000 800 600 400 200 100 80 60 40 20 10 8 6 4 2 1 0.8 0.6 0.4 0.2 0.1 0.08 0.06 0.04 0.02 0.01 0.02 0.04 0.06 0.08 0.1 0.2 0.4 0.6 0.8 1 8 10 20 40 100 2 4 6 2 4 6 8 Cut-off characteristic 1000 800 600 400 Pre-arcing time-current characteristics 5A 10A 200A 160A 200 20A 125A Cut-off current(peak value:ka) 200A 160A 125A 100A 75A 63A 50A 40A 30A 20A 10A 5A 100 80 60 40 20 10 8 6 4 2 1 0.8 0.6 0.4 0.2 30A 40A 50A 100A 75A 63A 0.1 0.08 0.06 0.04 0.02 0.01 10 20 40 60 80 100 200 400 600 800 1000 2000 4000 6000 8000 10000 Operating time(sec.) Prospective breaking current(rms:ka) Prospective breaking current (rms:a) 19

Ring Main Units Accessaries Vacuum Interrupter Figure 1. Current flow and driving force on arc for spiral contact Current path Driving force on the high current ARC ARC In the closed position, normal current flows through the interrupter. When a fault occurs and interruption is required, the contacts are quickly separated. The arc drawn between the surfaces of contacts is rapidly moved around the slotted contact surface by self induced magnetic effects, preventing gross contact erosion and the formation of hot spot on the surface. The arc burns in an ionized metal vapor, which condenses on the surrounding metal shield. At current zero the arc extinguishes and vapor production ceases. The metal vapor plasma is very rapidly dispersed, cooled, recombined, and deionized, and the metal vapor products are quickly condensed so that the contacts withstand the transient recovery voltage. (ⅰ) Weld (ⅱ) Bridge explosion (ⅰ) Contact jets (ⅱ) Shield involvement (ⅰ) Arc instability (ⅱ) Interruption Arc initiation High current arc mode Current zero Fault current Time (ms) Time (μs) Voltage Phenomena (ⅰ) Arc reignition (ⅱ) Restrikes (ⅲ) B. I. L (ⅳ) AC voltage withstand Recovery voltage Figure 2. AC arcing and interruption phenomena in vacuum. 20

Relay GIPAM LS Integrated Protection and Metering Device Integrating the other panel meter, protection relay, control switch on GIPAM Option - Transducer function - Sequence of event Special Features - Simplication of the equipments - Various display function - Various protection function & easy event analysis - Data communication function - High reliability with self-diagnosis function DPR LS high performance Digital Protection Relay Various unit types OCR, OCR/OCGR, OVR(UVR), OVR/UVR, OVGR, SGR Effective mutual back-up protecting. Setting range of time and current is wide and subdivided. Fault Recording function and SOE(Sequence of Event) function provides quickly accurate information to user that is used in analyzing causes of fault. High speed data communication by I-NET communication method, completely interface with SCADA Devices Protection/monitoring Code GIPAM DPR-011S DPR-111S DPR-211S DPR-311S DPR-411S DPR-511S Three-phase overcurrent 50-51 Zero-sequence overcurrent 50N-51N Selective zero-sequence overcurrent 67G Overvoltage 59 Undervoltage 27 Zero-sequence overvoltage 59N Measuring 21

Ring Main Units Accessaries Current transformer Max. system voltage kv 0.6 Primary current A 100 Secondary current A 5 Rated burden VA 10 Accuracy class 10P10 Short time current ka/1s 16 Rated frequency Hz 60 Polarity Subtractive Surge arrester The 273ESA Elbow Arrester is combined with a loadbreak elbow connector interface. Surge arrester Stud bolt Probe Bushing insert Spade terminal Cable adapter Bushing Shelded elbow Grounding eye Ground lead Cable Protective characteristics Note1) MCOV Duty cycle Maximum discharge voltage (kv crest) F.O.W. protective rating 8 20 microsecond current wave level (kvrms) (kvrms) 1.5kV 3kV 5kV 10kV 20kV (kv crest) 25kV 8.4 10 30.5 32.5 34.5 38.5 43.5 38.5 class 10.2 12 40.0 42.5 45.0 50.0 56.5 50.0 12.7 15 48.0 51.0 54.0 60.0 68.0 60.0 15.3 18 56.5 60.0 64.0 71.0 80.5 71.0 17.0 21 65.5 69.5 74.0 82.5 93.0 82.5 Note) 1. MCOV- Maximum Continuous Operation Voltage. 2. The front of wave (FOW) protective level is the maximum discharge for a 5kA impulse current wave producing a voltage wave cresting in 0.5 microseconds. Note2) 22

CTD (Condenser trip device) CTD is built as standard in the contactor with AC control of instantaneous excitation so that the contactor can be tripped within 30 seconds in the event of an electricity failure. The automatic trip circuit in the event of an electricity failure is to be built by a customer. AC input Control circuit diagram (For discharge) DC output Rating Description Type CTD-100 CTD-200 Rated input voltage(v) AC 100/110 AC 200/220 Frequency(Hz) 50/60 50/60 Rated impulse voltage(v) 140/155 280/310 Charging time Within 5 sec. Within 5 sec. Trip command possible time Max. 30 sec. Max. 30 sec. Terminal Input voltage range 85%~110% 85%~110% Capacitor rating(μf) 400 160 Closing coil (C) The coil operated only when the power is applied continuously over 45ms. It has built-in electrically antipumping circuit. Shunt coil (TC) When the VCB is 'ON' position, even though the control power of a shunt coil is 'OFF', the VCB maintains the 'ON' position. Rated voltage Rated current (A) Rated voltage Rated current (A) DC 24V 10 DC 110V 2.5 Note 1) Range of the normal operating voltage: 85~110% 2) DC 24V is the underdeveloped rating. DC 24V 10 DC 110V 2.5 Note 1) Range of the normal operating voltage: 70~110% 2) DC 24V is the underdeveloped rating. GAS pressure gauge Control connector Voltage detector Screw type Plug in type 12 13 14 17 18 19 01 02 03 04 05 06 07 08 09 10 11 23

Ring Main Units Installation R = 10D D : Cable diameter RPS RVB + RPL + RBR 4-18 38 Mounting hole 77 1348 77 12-Ø16 Mounting hole 120 626 40 102 327 524 327 102 466 120 90.5 377 144 315 144 315 61.5 607 RPF RPL, RBR RVB 6-Ø18 Mounting hole 4-Ø18 Mounting hole 4-Ø16 Mounting hole 70.5 470 303.5 61.5 607 70.5 315 607 61.5 70.5 315 607 61.5 24

Technical data Installation type Indoor type Rated voltage up to kv 24 Rated current A 630 A Rated current (RVB,RPF) A 200 Rated power frequency Hz 50 / 60 Rated short current ka/1s 16 Rated making current ka 41.6 Power frequency withstand voltage kv 50 Rated impulse withstand voltage kv 125 Operation type electromotion / manual Operating voltage V DC 110 Operating voltage (CTD Input) V AC 110 Insulation material SF6 Gas Rated filling pressure (20 C) Mpa. 0.034 (5 psi.g) Minimum operating pressure (20 C) Mpa. 0.014 (2 psi.g) Transfer current (RPF) A 800 Electrical life Electrical life (RVB) Mechanical life E3 E1, C1 M1 Standard IEC 60265-1, IEC 60420 Standard (RVB) IEC 62271-100 25

Ring Main Units Quality assurance Certified quality: KEMA, ISO 9001, ISO 14001 LS Industrial systems has integrated a functional organization into each of its units, the main purpose of which is to check quality and ensure the adherence to standards. Routine quality check While producing Tri-MEC RMU, various routine tests are taken for product capacity, which testing items are as shown follows. Filling pressure check Tightness check Opening and closing speed measurement Dielectric check Contact resistance check Seismic tests Application standard: JEAG5003-1999 26

Test category Norminals Structural excitation level(g) Direction Freq.(Hz) Waveforms Duration(S) Operability integrity X/Y/Z X Resonance search 0.1/0.1/0.1 Y 0.5-30 Random 328 N/A N/A test Z Real Kobe earthquake 0.3/0.3/0.15 XYZ Earth- 82 OK OK test quake 0.3/0/0 X OK OK 0.3/0/0.15 XZ OK OK 5 0/0.3/0 Y OK OK 0/0.3/0.15 YZ OK OK 0.3/0/0 X OK OK Sine 30 0.3/0/0.15 XZ Sine 30 OK OK waves test 10 0/0.3/0 Y Wave Waves OK OK 0/0.3/0.15 YZ OK OK 0.3/0/0 X OK OK 37.8 0.3/0/0.15 XZ OK OK 0/0.3/0 Y OK OK 12.2 0/0.3/0.15 YZ OK OK Resonance X search 0.1/0.1/0.1 Y 0.5-30 Random 328 N/A N/A test Z Ordering Information LGS R M 24 6 12 RT D LS Ring Main Unit R Switch type RPF, RPL, RPS, RVB, RBR Operating type M Automatic B Manual Rated Voltage 24 25.8(24)kV Rated Current 2 200A 6 630A Rated impulse withstand voltage 12 125kV BIL Cable connection type D Dead Break Type M Dead Break & Plug-in Type Switch and circuit type 21 2L-1F (RPS) 1L 1 LBS (RPL) 1F 1R 1V 21V 1Fuse-Combination LBS (RPF) Bus Rising (RVR) 1VCB (RVB) 2L-1VCB (RVS) 27

Leader in Electrics & Automation For your safety, please read user's manual thoroughly before operating. Contact the nearest authorized service facility for examination, repair, or adjustment. Safety Instructions Please contact qualified service technician when you need maintenance. Do not disassemble or repair by yourself! Any maintenance and inspection shall be performed by the personnel having expertise concerned. www.lsis.biz HEAD OFFICE Yonsei Jaedan Severance Bldg., 84-11, Namdaemunno 5ga, Jung-gu, Seoul, 100-753, Korea Tel. (82-2)2034-4870 Fax. (82-2)2034-4713 CHEONG-JU PLANT Cheong-Ju Plant #1, Song Jung Dong, Hung Duk Ku, Cheong Ju, 361-720, Korea Specifications in this catalog are subject to change without notice due to continuous product development and improvement. Global Network LS Industrial Systems (Middle East) FZE Dubai, U.A.E. Address: P.O.Box-114216, API World Tower, 303B, Sheikhe Zayed Road, Dubai, U.A.E. Tel: 971-4-332-8289 Fax: 971-4-332-9444 e-mail: hwyim@lsis.biz Dalian LS Industrial Systems Co., Ltd. Dalian, China Address: No.15, Liaohexi 3-Road, Economic and Technical Development zone, Dalian 116600, China Tel: 86-411-8273-7777 Fax: 86-411-8730-7560 e-mail: lixk@lsis.com.cn LS Industrial Systems (Wuxi) Co., Ltd. Wuxi, china Address: 102-A, National High & New Tech Industrial Development Area, Wuxi, Jiangsu,214028, P.R.China Tel: 86-510-8534-6666 Fax: 86-510-522-4078 e-mail: xuhg@lsis.com.cn LS-VINA Industrial Systems Co., Ltd. Hanoi, Vietnam Address: Nguyen Khe - Dong Anh - Ha Noi - Viet Nam Tel: 84-4-882-0222 Fax: 84-4-882-0220 e-mail: srjo@hn.vnn.vn LS Industrial Systems Tokyo Office Tokyo, Japan Address: 16FL, Higashi-Kan, Akasaka Twin Tower 17-22, 2-chome, Akasaka, Minato-ku Tokyo 107-8470, Japan Tel: 81-3-3582-9128 Fax: 81-3-3582-2667 e-mail: jschuna@lsis.biz LS Industrial Systems Shanghai Office Shanghai, China Address: Room E-G, 12th Floor Huamin Empire Plaza, No.726, West Yan'an Road Shanghai 200050, P.R. China Tel: 86-21-5237-9977 (609) Fax: 89-21-5237-7191 e-mail: jinhk@lsis.com.cn LS Industrial Systems Beijing Office Beijing, China Address: B-Tower 17FL.Beijing Global Trade Center B/D. No.36, BeiSanHuanDong-Lu, DongCheng-District, Beijing 100013, P.R. China Tel: 86-10-5825-6025,7 Fax: 86-10-5825-6026 e-mail: cuixiaorong@lsis.com.cn LS Industrial Systems Guangzhou Office Guangzhou, China Address: Room 1403,14F,New Poly Tower,2 Zhongshan Liu Road,Guangzhou, P.R. China Tel: 86-20-8326-6764 Fax: 86-20-8326-6287 e-mail: linsz@lsis.biz LS Industrial Systems Chengdu Office Chengdu, China Address: 12Floor, Guodong Buiding, No52 Jindun Road Chengdu, 610041, P.R. China Tel: 86-28-8612-9151 Fax: 86-28-8612-9236 e-mail: yangcf@lsis.com.cn LS Industrial Systems Qingdao Office Qingdao, China Address: 7B40,Haixin Guangchang Shenye Building B, No.9, Shandong Road Qingdao 26600, P.R. China Tel: 86-532-8501-6568 Fax: 86-532-583-3793 e-mail: lirj@lsis.com.cn 2008. 01 Ring Main Units(E) 2003. 06/(06) 2008. 01 Printed in Korea STAFF