Walking-Beam Interlock Módulo de enclavamiento recíproco para interruptores adyacentes Module d'interverouillage mécanique



Similar documents
Thermal Magnetic Trip Unit Disparador por sobreintensidad magnetotérmico

FG, JG, LG, MG, NG & PG


JG, LG 2/6 3/6 NG, PG

SENTRON Switching and Protection Devices Air Circuit Breakers

3500/15 Power Supply Bently Nevada* Asset Condition Monitoring

EGSTON Standard E2xFxWx 12W

New Media Power Socket Outlets. New Media Power Socket Outlets

Guía de instalación rápida. TEG-S16g TEG-S24g 1.01

AC/DC Power Modules C B. TML Series, 20 & 40 Watt. Features. 20 Watt Models

NM8, NM8S NM8, NM8S. Moulded Case Circuit Breakers. 3. Type designation. 4. Product overview N M 8 / / /

ENERGIA SOLAR FOTOVOLTAICA


Plug-in relays Mini ISO relays

INSTALLATION INSTRUCTION Vanities & Wall Sconce WS-77618

How To Operate A Gec Transfer Switch Open Transition Amp Power Supply

SHORE POWER. Safely Connecting Ships to Shore SAFETY QUALITY INNOVATION VALUE CUSTOMER SERVICE

Thermometer in stainless steel with capillary and switch contacts

MTB Load Cell. Globally Approved for Accuracy and Safety. MTB Load Cell

STR7 Low Profile LED Strip Luminaire

Explosion proof enclosures

OPERATING INSTRUCTIONS LOAD BALANCER COD GUARANTEE... 5

Relés e Contatores de Estado Sólido SIRIUS

GTEC transfer switch open transition

DECLARATION OF PERFORMANCE NO. HU-DOP_TN _001

Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx

5SV Residual Current Protective Devices

DECLARATION OF PERFORMANCE NO. HU-DOP_TD-25_001

Components for System Solutions E9/5. Ex d Enclosure System Made of Light Metal or Stainless Steel, "Flameproof Enclosure" Series

Portable Solar Kits Owner s Manual

5-Port Gigabit GREENnet Switch TEG-S5g ŸGuía de instalación rápida (1) ŸTechnical Specifications (3) ŸTroubleshooting (4)

SIMATIC. ET 200S distributed I/O Digital electronic module 8DI DC24V (6ES7131-4BF00-0AA0) Preface. Properties 1. Diagnostics 2.

E-STOP relays, safety gate monitors

OTM_F_C_. Installation instruction 34OTM_F_C_ / 1SCC303009M0201

R&S SMZ Frequency Multiplier Specifications

Work Instruction (Instruccion de Trabajo) Wistron InfoComm (Texas) Corp.

Photovoltaic Solar Energy Unit EESFB

SOLAR ELECTRIC MODULE ES-124 & ES-62T Owners Manual and Installation Guide

3500/40M Proximitor* Monitor

SKP Series SKP15U.. Gas Valve Actuator with Safety Shutoff Function

Save this booklet PLEASE READ THIS BOOKLET BEFORE OPERATION A CUT ABOVE THE REST 110/220 VOLT ELECTRIC SHEAR SERIAL NUMBER PURCHASE DATE

Quick Installation Guide. 1000Base-SX/LX Fiber Converters

DSD 70 Dual Channel Hall Effect Speed Sensor for Railway Applications, compliant with EN 50155

E Instrucciones de montaje GB Assembly instructions F Instructions de montage

How To Install An Icc Media Center

SIRCOVER. Manual changeover switches from 125 to 3200 A. Changeover switches. Function. Advantages. The solution for.

INSTRUCTION MANUAL VRT-200. TECSYSTEM S.r.l. Via Cristoforo Colombo, 5/C Corsico (MI) phone / Fax:

MCR1900 Media Converter 19-Slot Chassis

Explosion Proof Dynamic Brushless Servo Motors

Coils - Connectors. Coils Connectors. Summary. RE / /10 Replaces: RE / Description

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Molded Case Circuit Breaker Specifications Bulletin Number 140U-D

ENCLOSURE R DESIG I NS 2009

Eaton UPS kVA. Energía. 20 kva/18 kw and 30 kva/27 kw 0.9 power factor. True double-conversion online UPS.

225C-024T-05. Continuous control rotary drive without spring return. Technical data sheet. Description. Technical data. Actuators

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start * see variants. Applications.

SINAMICS drives SINAMICS DCM. DC converters from 6 kw to 2500 kw for variable-speed direct-current drives. Load-balanced control application

820 NOVA mv THERMOPILE POWER SUPPLY THERMOELECTRIC SAFETY DEVICE SERVO-CONTROLLED PRESSURE REGULATOR SHUT-OFF SOLENOID VALVE.

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

AF / AF09Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals

IeC Medical Design Standards-3 rd Edition

DOCUMENTATION PD16 CP3-SVE-M75DC-24

3RT1015-1BB41 CONTACTOR, AC-3 3 KW/400 V,

Product Overview 2Pro AC Devices Provide Overcurrent/ Overvoltage/Overtemperature Protection for AC Industrial and Appliance Applications

Installation Instructions for EHD, EDB, EDS, ED, EDH, EDC, FDB, FD, HFD, FDC, HFDDC Circuit Breakers and Molded Case Switches

Thermal-Magnetic Circuit Breaker M1-..

PNOZsigma - Base units

Technote. Frese OPTIMA Compact actuators DN10-DN32. Application. Features thermic actuators. Features motoric actuators. Approval.

3500/25 Enhanced Keyphasor*Module

Industrial VRS Magnetic Speed Sensors

ZS10 Screw Clamp Terminal Block

Power Supplies 3. SDN-P DIN Rail Series

Technical catalog - Edition SACE Tmax PV Adaptability, versatility and complete freedom continue

Datasheet. Managed PoE+ Gigabit Switches with SFP. Models: US W, US W, US W, US W

ENGLISH FRANÇAIS DEUTSCH ESPAÑOL ÐÓÑÑÊÈÉ

Variable speed drives for synchronous and asynchronous motors

2 series II COMPANION MULTIMEDIA SPEAKERS

STAR Linear Bushings and Shafts Supplement RE / Linear Motion and Assembly Technologies

Machine Safety Switches

Siemens Integrated Substation Condition Monitoring System. Circuit Breaker Monitoring

Q SERIES Ø14mm (.551") Panel Mount LED Indicators Distinctive features and specification

NTMS4920NR2G. Power MOSFET 30 V, 17 A, N Channel, SO 8 Features

PRODUCT GUIDE. SL Medium Voltage IEC Vacuum Contactors

Operating Instructions

Anfora Book. WOOD TOUCHED BY LIGHT High Fidelity. Collection 2013 COLLECTION 2013

Photovoltaic System Overcurrent Protection

Motor suppressors. Standardized motor suppression from Murrelektronik

Laserlyte-Flex Alignment System

OPERATING MANUAL CONTRACTOR STYLE AXIAL FANS

698/699 LED Signal Tower Kompakt 37

BT300 HVAC Drives Conventional Bypass (C-Bypass) Options

Quick Installation Guide TK-209K TK-409K

1/2" (12.7 mm) Conductive Plastic and Cermet Potentiometer

Nominal Power [W] Radiance Angle [ ] Color Temp. [K]

Core Fittings C-Core and CD-Core Fittings

Ground Liner Luminaire. Luminaria. 43 mm (1.69 in) Ground Liner. High recessed box+luminaire. Cajetín de empotrar alto+luminaria. 130 mm (5.

Description SO-8. Table 1. Device summary. Order codes. SO-8 (tape and reel) TO-92 (Bag) TO-92 (Ammopack) TO-92 (tape and reel)

Transcription:

s Walking-Beam Interlock Módulo de enclavamiento recíproco para interruptores adyacentes Module d'interverouillage mécanique Installation Instructions / Instructivo de Instalación Item: U.S. Cat. No. Euro Order No. WBMPFM 3VL98008LC01 For Use With Frame NG, PG Para Usar Con Caja Base NG, PG Hazardous Voltage. Use only with Siemens certified Components. Utilizar únicamente con componentes certificados de Siemens. A utiliser uniquement avec les composants certifiés Siemens. Ø =.26 [ Ø = 6.5 mm ] NOTE - These instructions do not purport to cover all details or variations in equipment, or to provide for every possible contingency to be met in connection with installation, operation or maintenance. Should further information be desired or should particular problems arise, which are not covered sufficiently for the purchaser s purposes, the matter should be referred to the local Siemens sales office. The contents of this instruction manual shall not become part of or modify any prior or existing agreement, commitment or relationship. The sales contract contains the entire obligation of Siemens. The warranty contained in the contract between the parties is the sole warranty of Siemens. Any statements contained herein do not create new warranties or modify the existing warranty. Trademarks - Unless otherwise noted, all names identified by are registered trademarks of Siemens AG or Siemens Industry, Inc. The remaining trademarks in this publication may be trademarks whose use by third parties for their own purposes could violate the rights of the owner. Cal ISO 6789 10 mm 7/16 Ø =.27 [ Ø = 7 mm ] 10 mm MTRPB MTRPM MTRPY MTRPN MTRPR 3VL9800-3MJ01 = 24 Vdc 3VL9800-3ML01 = 42-48 V ac/dc 3VL9800-3MS01= 60 V ac/dc 3VL9800-3MN01 = 110-127 V ac/dc 3VL9800-3MQ01 = 220-250 V ac/dc Notice: Control circuit interlocking recommended to prevent unintended operation of the motor operator in conflict with the walking beam interlock. [ Aviso: El enclavamiento del circuito de control es recomendado para prevenir la operación involuntaria del accionamiento de motor en conflicto con el modulo de enclavamiento mecánico. ] 4 X M6 X 16mm -2 X 6 X M6 X 20mm 10 X 8 X M6 X 1 WBMPFM / 3VL98008LC01 806892 _ 8 0 6 8 9 6 A 0 1 1 / 10 I.L. No. 806896A01

1 Trip [ Interrumpir ] 2 A [ Interruptor A ] 1 2 3 clic B [ Interruptor B ] 1 2 3 clic 2 / 10 806896A01

Hazardous Voltage. Supplied by Customer: / [ Proveído por el Cliente: ] Rear Connecting NG ( 3 Pole) [ Conexión Trasera NG ( 3 Polos) ] Supplied by Customer: / [ Proveído por el Cliente: ] 17.03 [433] Rear Connecting NG (4 Pole) [ Conexión Trasera NG (4 Polos) ].12.24 [ 3 6 mm ].12.24 [ 3 6 mm ] 3 / 10 806896A01

Supplied by Customer: / [ Proveído por el Cliente: ] Front Connecting NG ( 3 Pole) [ Conexión Frente NG ( 3 Polos) ] 17.03 [433].12.24 [ 3 6 mm ] Supplied by Customer: / [ Proveído por el Cliente: ] Front Connecting NG (4 Pole) [ Conexión Frente NG (4 Polos) ] 10.10 [257] 7.60 [193] 1.50 [38] TYP 20.00 [508] 3.00 [76] TYP 6.00 [152] TYP 2.07 [53] TYP 7.85 [199] 8.44 [214] 1.57 [40] TYP 3.09 [78] 14.25 [362] 2.17 [55] TYP 1.50 [38] TYP 1.44 [37] 2.63 [67] 3.05 [77] 6.92 [176] 8.04 [204] 26 X Ø.27 [Ø7] 4.50 [114] 5.35 [136] 7.00 [178] 25.03 [636].12.24 [ 3 6 mm ] 4 / 10 806896A01

Hazardous Voltage. Supplied by Customer: / [ Proveído por el Cliente: ] 3 Pole [ 3 Polos ] QTY - 2.41 [10] 11.54 [293] 22.88 [581] 22.48 [571] Supplied by Customer: / [ Proveído por el Cliente: ].41 [10] 1.02 [26] 1.26 [32].12 [3] 4 Pole QTY - 2 33.90 [861] 6 X Ø.27 [Ø7].45 [11].43 [11] 16.06 [408] 18.56 [472] 33.50 [851] 1.26 [32].12 [3] 4 Pole QTY - 1.41 [10] 16.14 [410] 15.77 [400] 10.45 [265] 6XØ.27 [Ø7] 5.88 [149] 8.51 [216] 4.28 [109].41 [10] 5 / 10 806896A01

Supplied by Customer: / [ Proveído por el Cliente: ] 3 4 X 4 X 4 X 4 X 27 lb. in. [ 3 Nm ] Front view [ vista frontal ] 4 EX: 4 Pole 4 X M6 Rear view [ vista Trasera ] 4 X M6 27 lb. in. [ 3 Nm ] 4 X M6 X 16MM 5 Ex: 4 Pole Front view [ vista frontal ] 6 X M6 6 X M6 6 X 27 lb. in. [ 3 Nm ] 6 X M6 X 20mm 6 / 10 806896A01

6 Hazardous Voltage. WBMPFM 6 X 27 lb. in. [ 3 Nm ] EX: 4 Pole 6 X M6 4 X M6 2 X M6 X 20mm WBMPFM 4 Pole ONLY [ 4 Polos SOLAMENTE ] 3 and 4 Pole [ 3 y 4 Polos ] 4 X M6 X 20mm Rear view [ vista Trasera ] 7 8 3 Pole / Polos 4 X 35 lb.in. [ 4 Nm ] 4 Pole / Polos 6 X 35 lb.in. [ 4 Nm ] 7/16 EX: 4 Pole 3 Pole Polos - 4 X 1/4-20 4 Pole Polos - 6 X 1/4-20 4 X 8 X 11 lb.in. [ 1.2 Nm ] 3 Pole Polos - 4 X 1/4 4 Pole Polos - 6 X 1/4 9 EX: OFF / 0 7 / 10 806896A01

10 6mm [ Interruptor ] A [ Interruptor ] B C 35 lb. in [ 4 Nm ] 9 lbf. [ 40 N ] A B C B 9 lbf. [ 40 N ] A Test: [ Prueba: ] 11 [ Interruptor ] A [ Interruptor ] B EX: 11 - f [ Interruptor ] A [ Interruptor ] B A Result [ Resultado ] B Repeat [ Repetir ] 11 - a 5X 11 - b 5X Step 12 [ Paso 12 ] 11 - c 5X 11 - d 11 - e 1X 1X Step 15 [ Paso 15 ] 11 - f 1X 8 / 10 806896A01

Hazardous Voltage. 12 13 C 35 lb. in [ 4.0 Nm ] 9 lbf. [ 40 N ] A B C B 9 lbf. [ 40 N ] A 14 Step 11 [ Paso 11 ] Test: = [ Prueba: ] Step 15 [ Paso 15 ] 15 35 lb. in [ 4.0 Nm ] 9 / 10 806896A01

Hazardous Voltage. General information: [ Información General: ].91 [ 23 ] 1.77 Max [ 45 Max ] 3.70 Max [ 94 MAX ] 3 Pole / Polos 12.00 [ 305 ] 4.84 [ 123 ] 12.00 [ 305 ] 4 Pole / Polos 8.56 [ 225 ] 20.00 [ 508 ] 20.00 [ 508 ] For Support in Europe refer to : Bestell-Nr. / Order No.: 3ZX1012-0VL68-7AA5 Internet: www.siemens.de/lowvoltage/technical-assistance GWA 4NEB 179 6896-10 DS 02 Technical Support: Toll Free: 1-800-241-4453 Internet: www.usa.siemens.com/powerdistribution Subject to change without prior notice Siemens Industry Inc. 2010 Siemens Industry, Inc., Norcross, GA 30092 U.S.A. 10 / 10 806896A01