Copper Meter Resetters



Similar documents
Copper Meter Insetters

COPPER METER SETTERS A.Y. McDONALD MFG. CO. WATER SERVICE PRODUCTS. TO SET 5/8", 5/8" X 3/4", 3/4", 1", 1 1/2", and 2" Water Meters

8D.1 BALL ANGLE METER VALVES - 3/4" & 1" P B E B B B-24267

E FORD METER BOX COMPANY, NI

FUEL SYSTEMS OUR PARTS PUT YOU IN THE PASSING LANE. Protect your fuel system. velvac.com

Pipe threads for tubes and fittings where pressure-tight joints are not made on the threads. (requires PTFE sealing tape or liquid sealant).

Hose Clamps & Fittings

3", 4", 6" & 8" Model H Series Alarm Check Valve Installation and Maintenance Guide

2013 Edition. Flanged fittings 30"-64" NSF. industrial Applications, water & Wastewater. Certified to ANSI/NSF 61

WATER PRESSURE REDUCING VALVES

SPERRYN GAS CONTROLS DELTA FLUID PRODUCTS LIMITED

Double-Headed Screw 1. 3/4" FIP x 3/4" MIP x 1/4" hole 2. 3/4" Fip x 3/4" MIP. Feed Water Connector 1. 1/2" FIP x 1/2" MIP x 1/4" OD 2. 3.

Replacement parts. WM97+ gas-fired water boiler Boiler Manual. OBTAIN PARTS ONLY THROUGH WEIL-McLAIN THE BOILER CONTAINS CERAMIC FIBER MATERIALS

One Year Warranty. Stock U.S. # of Volts Weight CONN. Height Dia. Watts # GAL. Elements INS. Inches NATURAL GAS* Six Year Warranty

GAS DISTRIBUTION PRODUCTS STEEL SERVICE TEES

Manufactured under one or more of the following: U.S. Patent No. 4,614,113; 4,813,281

WATER SERVICE 2

STEAM AND CONDENSATE PIPING AND PUMPS DESIGN AND CONSTRUCTION STANDARD PART 1: GENERAL Purpose:

AIR OPERATED OIL PUMPS AND KITS

TYPE E Main Valve Sizes 3 /8 through 12

Fixtures - Parts - Accessories to shampoo bowls

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

OPERATING INSTRUCTIONS AND PARTS LIST FOR U U UNDERGROUND HOSE REELS

V47 Series Temperature Actuated Modulating Water Valves

Mueller B-101 and A-3 Drilling and Tapping Machines

2010 Residential Water Heater Replacement Check List

MBA-MM-1040/10/13/1665 MULTI MEDIA FILTERS

NITROUS TRANSFER PUMP INSTRUCTIONS

TAMPERS Tabor Place, Santa Fe Springs, California, CA 90670, U.S.A.

REGULATORS 175/153 Series

INSTALLATION AND OPERATION INSTRUCTIONS - (LOW FLOW MODELS) (Before installation, compare electrical needed for the model of heater selected)

TABLE 1. Rugged cast aluminum alloy casing,celcon waterways with nichrome parts White (unless stainless steel housing)

123 Industrial Loop Road Paynesville, MN Phone:

NFPA31FuelOilPiping 1 Revised

MODEL G300 BRAKE BLEEDER

Plumbing. Helpful Hints Residential Construction. Lincoln County. Bert Polk Plumbing Inspector

SRA-125/SRAX-125 Double-Rail Lift-Out Rail System Installation & Service Manual with Parts List

Installation and Operating Instructions Installation Instructions for SS EPE-316L Series

DARTMOUTH COLLEGE DESIGN January 3, 2012 & CONSTRUCTION GUIDELINES

Parts Manual. TWIN 2 & 3 Parts & Accessories F210846R01. Your efficiency is our Challenge!

Watts Pure Water Systems

SECTION DUCTILE IRON PIPE AND FITTINGS

Model 1210C Battery Powered Pump Shown. Description

Your safety and the safety of others are very important.

Copper and Copper Alloy Tube, Pipe and Fittings

SECTION STORM DRAINAGE SYSTEM

American- Darling 5¼" B-84-B-5.

MASTER. Installation and Operation Manual. Water Conditioning Corp. MCA Time Clock Series Residential Softeners. February 2011 Version

GEET Fuel Processor Plans

Pipe Valves, Fittings and Nipples Pressures to 15,200 psi

Goulds Water Technology

INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate Locks

System Accessories Pricing. Page 0 Effective 7/02

Telescoping Post Indicator Wall Post KENNEDY VALVE ISO 9000 ISO 14001

SURGICAL SCRUB SINKS INSTALATION-OPERATION-MAINTENANCE USER MANUAL

SIMPLAIR PIPING TOOL

WD600 STEAM TRAPS. Thermodynamic Steam Trap

MAINTENANCE MANUAL INDEX DOUBLE CHECK ASSEMBLIES MODELS 850 & 850U 1/2" - 2"

Mueller. Pipe Repair Products. Saddles Tapping Sleeves Pipe Repair Clamps A complete selection for all types of pipe... all from a single source.

RAPID RESPONSE Model RSV-1 Residential Shut-Off Valve, 1 Inch and 2 Inch (DN25 and DN50) for Dual-Purpose Residential Water Supply General Description

PARTS CATALOG RPPCR01111_Front_Backcx.indd 1 RPPCR01111_Front_Backcx.indd 1 11/21/11 1:41 PM 11/21/11 1:41 PM

Jay R. Smith Mfg. Co.

MODEL 565E - 22 TON AIR/HYDRAULIC AXLE JACK

INSTALLATION INSTRUCTIONS GEO-BOOSTER TM

Morrison Bros. Co. General Product Specifications

Cajon VCR Fittings. Flanges, Fittings, & Components. Cajon & Swagelok Fittings. Cajon VCR Fittings. Nuts, Caps, & Plugs. Socket Weld Glands

AIR LINE VALVES AND GAUGES

VOYAGER 570G. 744A Sprayer Control

Series Hose Reels

EXHIBIT "A. Technical Specifications for Water and Sewer Service Lines

Fluid Monitoring and Inventory Management

Model 43AP Pneumatic Controller, Style B

PLUMBING VALVES HOUSTON ORLANDO GREENVILLE 800/ / / TOTAL MAINTENANCE SOLUTIONS

WATER & SEWER CORROSIVE RESISTANT PRODUCTS

INSTRUCTIONS AND PARTS LIST FOR MODEL 70H & 75H HAND-OPERATED HYDRAULIC PRESS

TECHNICAL BROCHURE B5-33GB 5GB, 7GB, 10GB, 18GB, 25GB, 33GB HIGH PRESSURE MULTI-STAGE BOOSTER PUMP

Mustang Series PRESSURE REDUCING CONTROL VALVE WITH PRESSURE SUSTAINING FEATURE. M115-2 (Globe) M (Angle) Schematic. Standard Components

Rental Services Temporary Cooling - Flexible Water Hose

Flare Fittings. The World Standard. SAE 45 Flared Fittings... D4. Inverted Flared Fittings... D14. Access Valves... D18

Indirect-Fired Storage Water Heater Models WH-30 through WH-80 INSTALLATION AND OPERATING INSTRUCTIONS

SECTION COMMERCIAL PLUMBING FIXTURES

ASME/ANSI B Cast Iron Pipe Flanges and Flanged Fittings ASME/ANSI B Malleable Iron Threaded Fittings ASME/ANSI B16.

Water Distribution Products Full-line product offering

Installation Manual DIAPHRAGM WELL TANK

AIR RELEASE, CLEANOUT, AND SEWER MANHOLES

THE JERSEY CITY MUNICIPAL UTILITIES AUTHORITY REQUIREMENTS FOR FIRE AND DOMESTIC WATER LINE AND METER INSTALLATIONS

Fleck Service Manual INSTALLATION AND START-UP PROCEDURE TABLE OF CONTENTS JOB SPECIFICATION SHEET

TWO-WAY DIVERTER WITH THREE-WAY HAND SHOWER

I N S T A L L A T I O N I N S T R U C T I O N S F O R T H E H i l k o i l Energy S aving Hot Water Kit

e perts in our field CONTINENTAL PARTS CATALOGUE

Transport & Automotive CATALOGUE. March Customer Service Phone: Fax: sales@tubefit.com.au.

STATFlow. Direct-to-Drain System. For use with STATIM 2000 and STATIM 5000 Autoclaves. Installation Guide and Operator s Manual

Stainless Steel Single and Dual Circulation Kits

Installation Manual. Thermomax Solar Water Heater ... Installation Procedure for Flatroof and Ground. Revision 8

James M. Pleasants Company

with installation dynafact boost GAUGE this manual is for use with systems

Installation Manual. Solar Pool Heating System. Read the complete manual before beginning the installation

Electronic Wallmount Faucet 1500T4 & 1501T4 Series

Mini Tank water heater Electric undersink Water heaters GL GL 4 - GL 6+

Fabricated Drainage Products

Transcription:

Copper Meter Resetters To Set 5/8", 5/8" x 3/4", 3/4", 1", 1 1 2" & 2" Water Meters 11/12

Table of Contents Page Page Meter Resetters 5/8", 5/8" x 3/4", 3/4", & 1" Horizontal Inlet and Outlet Series 710 General Information...45 Series 717 Low Rise Style... 6 Series 718 Horizontal Style... 7 Series 719 Vertical Style Meter Thread x Meter Thread... 8 Series 768 Horizontal "F" Style Flexible... 9 Meter Resetters 1 1 2" & 2" Vertical Inlet and Outlet Series 718 No Bypass...12 With Bypass...13 Accessories Gaskets...14 Meter Bushings / Adapters...14 Meter Dimensions...14 Tandem Options...15 Sectional View...15 Series 758 Crab Style Tandem...10 Inverted Tandem...10 Inline Tandem...11 Page 45 Page 7 710 Series 718 Series Page 6 717 Series Page 6 717204XDCA Series 717 with Backflow Preventer and Thermal Expansion Tank (Tank must be purchased separately). 717204XDCC Series 717 used to retrofit existing high rise meter pit and standard meter resetter with backflow preventer and pressure relief valve. 2 800.292.2737 FAX 800.832.9296 sales@aymcdonald.com aymcdonald.com 1112

General Information A.Y. McDonald Mfg. Co. Resetters offer a wide variety of options for resetting your current water meter to various heights and locations. Resetters are used where the meter is already installed and the service lines are in place, but the meter needs to be relocated above or next to the current line. A.Y. McDonald Mfg. Co. resetters provide you with an array of variations that will see you through any relocation project. Common resetter installations are shown below. You can customize your resetter solution on the pages within, or contact our factory professionals to help you through. Brass materials meet or exceed AWWA C800 (latest revision) Copper tubing has a 13 16" O.D. for 5/8", 5/8" x 3/4" or 3/4" meter resetters, 1 1 8" O.D. for 1" meter resetters, 1 5 8" for 1 1 2" meter resetters and 2 1 8" for 2" meter resetters. Solder is nolead. EPDM rubber gaskets are furnished as standard. Contact factory for fiber or leather gaskets. All meter resetters are factory tested air under water at 85 PSIG. Brass support bar is standard on 18" and higher meter resetters. Meter resetter heights over 24" available on special order. All meter swivel nuts have wire seal hole. Lockwing ball style meter valves are standard. Meter swivel nuts with meter support saddle are standard, except where noted. All copper meter resetters can be supplied with a test valve on the outlet tubing. For dual check backflow valves, see catalog section 13. Brace eye hole accepts 1/2" iron pipe or PVC for 5/8", 5/8" x 3/4" and 3/4" meters and 1" vertical meter resetters. Brace eye hole accepts 3/4" iron pipe or PVC for 1", horizontal meter resetters. Brace eye hole accepts 1" iron pipe or PVC for 1 1 2" & 2", horizontal meter resetters. BEFORE AFTER 1112 800.292.2737 FAX 800.832.9296 sales@aymcdonald.com aymcdonald.com 3

710 SERIES The A.Y. McDonald Meter Resetter is a unique and patented product designed to easily retrofit existing meter installations to include a dual check backflow preventer, or pressure relief valve. This is accomplished without the high risk of cutting into old service lines, or the expensive process of digging up and replacing existing meter boxes or pits. This retrofitting can be easily performed in even the most confined meter boxes. Before NOTE: Meter box sold separately Meter Dimensions Meter Size 5/8" 5/8" x 3/4" 3/4" AMeter Threads 3/4" 1" 1" BLay Length 7 1 2" 7 1 2" 9" A.Y. M c Donald Spacing* 7 13 16" 7 13 16" 9 5 16" After NOTE: Meter box sold separately Available for 5/8", 5/8" x 3/4", or 3/4" meters Cast Brass Meter Nuts with Rubber Gaskets Copper Tubing Cast Brass Base Meter Threads Patent No. 4,691,727 Dual Check Backflow Preventer (optional) Meter Threads ASSE listed dual check Pressure Loss Data 5/8" Series 710 with backflow 5/8" Series 710 without backflow 20 5/8" x 3/4" Series 710 with backflow 5/8" x 3/4" Series 710 without backflow 30 3/4" Series 710 with backflow 3/4" Series 710 without backflow WATER FLOW (Gallons Per Minute) 15 10 5 WATER FLOW (Gallons Per Minute) 20 15 10 5 WATER FLOW (Gallons Per Minute) 25 20 15 10 5 0 0 0 5 10 15 20 0 2.5 5 7.5 10 PRESSURE DROP (Pounds per Square Inch) PRESSURE DROP (Pounds per Square Inch) 0 0 5 10 15 20 25 30 PRESSURE DROP (Pounds per Square Inch) Thermal Expansion Warning Creating a closed condition in a hot water system with the installation of a nonreturn barrier (such as a Check Valve or Backflow Preventer between the system piping and the public supply) can result in extreme pressure rises caused by thermal expansion and/or water hammer. This thermal expansion can damage piping, valves, and other components in the system. The installation of a pressure relief device or thermal expansion tank can avoid possible damages. 4 800.292.2737 FAX 800.832.9296 sales@aymcdonald.com aymcdonald.com 1112

Offset Left Standard 710 SERIES Approx. 6 Approx. 3 Side View 710 Inlet Series Style Meter Size Meter Height Meter Connections Bottom Bar 1/2" FNPT Space Tube Offset Options Bottom Bar Tap 710 = Standard For crossed sized meter sets A = 5/8" B = 5/8" x 3/4" C = 3/4" R = Right offset A B Tap Locations Model 710106NN 1 1 = 5/8" 2 = 5/8" x 3/4" 3 = 3/4" 06 3" 6" 7" 12" Resetters with crossover meter sizes are available, contact factory. * For angle ball valves integral to resetter, contact factory. Not all combinations available, contact factory with your requirements. Most Meter RESetters are Made to order and are not returnable. Please verify with the factory that the model number you have configured is available and meets your requirements. * N N N = No valve (meter nut only without saddle) Q = Lockwing ball valve (without saddle) Side View 72 Left Offset Standard Inlet Model 710103NN X72 = No option C = Dual check on inlet H = Dual check on outlet J = Adapter idler on outlet (sized to fit meter) U = UFR on outlet (Integral) A B Tap Locations X72 See above side view as required = No tap A = Tap inlet, no plug B = Tap outlet, no plug D = Tap outlet, with 125# PRV E = Tap inlet, with 175# PRV F = Tap outlet, with 175# PRV G = Tap inlet, with plug H = Tap outlet, with plug L = Tap inlet, with 125# PRV (Inlet is city side, outlet is house side) Ordering Options Separately Dual Check Backflow Preventer (Inlet side) 7113AN 34 For 5/8" meter 7113AN 44 For 5/8" x 3/4" and 3/4" meter Inlet: Male meter thread Outlet: Female meter thread (union) Dual Check Backflow Preventer (Outlet side) 7113NA 43 For 5/8" meter 7113NA 44 For 5/8" x 3/4" and 3/4" meter Inlet: Female meter thread (union) Outlet: Male meter thread Pressure Relief Valve 710P125 125 lb. rated 710P175 175 lb. rated 1/2" MNPT thread 710J11 Meter Adapter Idler (New Style) 3 3/4" long with gasket, adapts basic 710 Series unit (less backflow preventer) to 7 1 2" lay length 5/8" meter 710J22 Meter Adapter Idler 3 3/4" long with gasket, adapts basic 710 Series unit (less backflow preventer) to 7" lay length 5/8" x 3/4" meter 710J23 Meter Adapter Idler 1 1 2" long with gasket. Use with 710 Series unit and backflow preventer to increase lay length 3/4" meter Plug 73208 1/2 1112 800.292.2737 FAX 800.832.9296 sales@aymcdonald.com aymcdonald.com 5

717 SERIES Low Rise Style Resetter 90º tubing to bottom bar is standard, contact factory for other options. The A.Y. McDonald 717 Series low rise resetter allows you to reset a meter incorporating an inlet or outlet shut off valve or check valve. It also offers several options for taps to incorporate pressure relief valves or sampling valves before or after the meter. Ninety degree tubing to bottom bar is standard, other options are available (contact factory for information). 90º Offset Right View Standard INLET Meter Thread OUTLET Meter Thread 717 Left Offset Inlet (city side) Series Style Meter Size Meter Height Meter Connections Bottom Bar FNPT Optional Offset Tap Location Bottom Bar Tap 717 = Standard For crossed sized meter sets A = 5/8" B = 5/8" x 3/4" C = 3/4" Tap A Offset Left: U = 5/8" V = 5/8" x 3/4" W = 3/4" X = Offset Left Tap D (bottom) Tap C (top) Tap B 2 1 = 5/8" 2 = 5/8"x 3/4" 3 = 3/4" 4 = 1" 04 4" 6" for 1" meter only. For special heights, contact factory. W D C = Angle single check valve on outlet D = Angle dual check valve on outlet (ASSE 1024) W = Angle lockwing ball valve X = No valve meter nut only For other special meter connections, contact factory. Outlet (house side) Model 717204WD Right Offset Inlet (city side) Tap A Tap C (bottom) Tap B Tap D (top) Outlet (house side) = No Tap A = Inlet Left B = Outlet Left C = Outlet Top D = Outlet Bottom 45 = 45º 60 = 60º 180 = 180º = No tap A = 1/2" FNPT no plug B = 1/2" FNPT with brass square head plug C = 1/2" FNPT 125# PRV D = 3/4" FNPT no plug (only 1" resetter) E = 3/4" FNPT with brass square head plug (only 1" resetter) Series 717 is typically viewed from the inlet side, and is fabricated as a right offset (see photo above and at right). This is critical when considering tap locations. Left offset is available upon special request contact factory. Not all combinations available, contact factory with your requirements. Most Meter RESetters are Made to order and are not returnable. Please verify with the factory that the model number you have configured is available and meets your requirements. 6 800.292.2737 FAX 800.832.9296 sales@aymcdonald.com aymcdonald.com 1112

718 SERIES Horizontal Style Resetter Minimum 10" height on 1" resetters, or 12" on 1" resetter with angle dual check. The A.Y. McDonald 718 horizontal resetter allows you to reset a meter incorporating an inlet or outlet shut off valve or check valve while offering several height options. It also offers several options for taps to incorporate pressure relief valves or sampling valves before or after the meter. Depending on valve configurations, minimum heights may vary. INLET Meter Thread OUTLET Meter Thread 718 Series Style Meter Size Meter Height Meter Connections Bottom Bar FNPT Tap Location Bottom Bar Tap For Tandem Series 718 = Standard For crossed sized meter sets A = 5/8" B = 5/8" x 3/4" C = 3/4" 2 1 = 5/8" 2 = 5/8"x 3/4" 3 = 3/4" 4 = 1" Model 718207WX 07 07" 09" 10" 12" 15" 18" 21" 24" For special heights, contact factory. W X Blank = No Tap A = 1/2" FNPT inlet B = 1/2" FNPT outlet C = Angle single check valve on outlet D = Angle dual check valve on outlet (ASSE 1024) W = Angle lockwing ball valve X = No valve meter nut only For other special meter connections, contact factory. Blank = No Tap A = 1/2" FNPT no plug B = 1/2" FNPT with brass square head plug C = 1/2" FNPT 125# PRV D = 1/2" FNPT 175# PRV 758 Series Horizontal Tandem Setter Example 758207WX Tandem resetters are supplied with adapters and S tube. Please specify device length and threads when ordering. Not all combinations available, contact factory with your requirements. Most Meter RESetters are Made to order and are not returnable. Please verify with the factory that the model number you have configured is available and meets your requirements. 1112 800.292.2737 FAX 800.832.9296 sales@aymcdonald.com aymcdonald.com 7

719 SERIES Vertical Style Resetter Meter Thread x Meter Thread The A.Y. McDonald 719 vertical to horizontal resetter allows you to reset a meter currently in a vertical position to a horizontal position incorporating an inlet or outlet shut off valve or check valve. It also offers several height options and several options for taps to incorporate pressure relief valves or sampling valves before or after the meter. Meter swivel nuts are less saddle 719 Model 7192 Series Style Meter Size Meter Height Meter Connections Bottom Bar FNPT Tap Location Bottom Bar Tap 718 = Standard For crossed sized meter sets A = 5/8" B = 5/8" x 3/4" C = 3/4" 2 1 = 5/8" 2 = 5/8" x 3/4" 3 = 3/4" 4 = 1" = Standard For special heights, contact factory. Q N Blank = No Tap A = 1/2" FNPT inlet B = 1/2" FNPT outlet A = Angle single check valve on outlet F = Angle dual check valve on outlet (ASSE 1024) Q = Angle lockwing ball valve N = No valve meter nut only For other special meter connections, contact factory. Blank = No Tap A = 1/2" FNPT no plug B = 1/2" FNPT with brass square head plug C = 1/2" FNPT 125# PRV D = 1/2" FNPT 175# PRV Not all combinations available, contact factory with your requirements. Most Meter RESetters are Made to order and are not returnable. Please verify with the factory that the model number you have configured is available and meets your requirements. 8 800.292.2737 FAX 800.832.9296 sales@aymcdonald.com aymcdonald.com 1112

768 SERIES Horizontal "F" Style Flexible Resetter Minimum 15" height on 1" resetters. Resetters with crossover meter sizes are available, contact factory. The A.Y. McDonald 768 horizontal F Style (Flexible) resetter allows you to reset a meter incorporating an inlet or outlet shut off valve or check valve. It also offers several height options and flexibility if existing set is not aligned correctly. INLET Meter Thread OUTLET Meter Thread Model 768112WX 768 1 12 W X Series Style Meter Size Meter Height Inlet Outlet Meter Connections 768 = Standard For crossed sized meter sets A = 5/8" B = 5/8" x 3/4" C = 3/4" 1 = 5/8" 12" 2 = 5/8" x 3/4" 15" 3 = 3/4" 18" 4 = 1" 21" 24" For special heights, contact factory. C = Angle single check valve on outlet (Not availabe on 1") D = Angle dual check valve on outlet (ASSE 1024) W = Angle lockwing ball valve X = No valve meter nut only For other special meter connections, contact factory. For Tandem Series 761 Series Horizontal Tandem Setter Example 761112WX Tandem resetters are supplied with adapters and S tube. Please specify device length and threads when ordering. Not all combinations available, contact factory with your requirements. Most Meter RESetters are Made to order and are not returnable. Please verify with the factory that the model number you have configured is available and meets your requirements. 1112 800.292.2737 FAX 800.832.9296 sales@aymcdonald.com aymcdonald.com 9

758 SERIES Crab Style Tandem Resetter Made to set two 7 1 2" meter thread x meter thread devices. The A.Y. McDonald 758 tandem resetter allows you to reset a meter and a device in one low profile compact setting. Meter swivel nuts are less saddle Model 7582NN X419 758 2 N N X419 Series Style Meter Size Meter Height Meter Connections Blank Space Crab Style 758 Tandem = Standard 2 = 5/8" x 3/4" 3 = 3/4" 4 = 1" For special heights, contact factory. N = No valve meter nut only For other special meter connections, contact factory. Inverted Tandem For installing a regulator and meter in an existing setting and there is little room above 2" rise from original meter height. The A.Y. McDonald 758 inverted tandem resetter allows you to reset a meter and a device with minimal rise as long as there is room below the existing meter. Meter swivel nuts are less saddle 758 2 Model 758202NN X406 02 X406 Series Style Meter Size Meter Height Meter Connections Blank Space Inverted Style N N 758 Tandem = Standard 1 = 5/8" 2 = 5/8" x 3/4" 3 = 3/4" For special heights, contact factory. N = No valve meter nut only For other special meter connections, contact factory. Meter swivel nuts are less saddle. Not all combinations available, contact factory with your requirements. Most Meter RESetters are Made to order and are not returnable. Please verify with the factory that the model number you have configured is available and meets your requirements. 10 800.292.2737 FAX 800.832.9296 sales@aymcdonald.com aymcdonald.com 1112

758 SERIES Inline Tandem Resetter The A.Y. McDonald 758 inline tandem resetter with additional options for shut off or check valves plumbed into the tubing to accept inline, a meter and a pressure regulating device. Please supply device length and end connection configuration when ordering. Resetters include 74620 meter coupling and 74619 adapter and gaskets. Meter swivel nuts are less saddle INLET Meter Thread OUTLET Meter Thread Model 758207QN X15.81 758 2 07 Q N X15.81 Series Style Meter Size Meter Height Meter Connections Blank Space Flange to Flange Spread 758 = Standard 1 = 5/8" 2 = 5/8" x 3/4" 3 = 3/4" 4 = 1" 07" 09" 10" 12" 15" 18" 21" 24" For special heights, contact factory. A = Angle single check valve on outlet F = Angle dual check valve on outlet (ASSE 1024) Q = Angle lockwing ball valve N = No valve meter nut only For other special meter connections, contact factory. Not all combinations available, contact factory with your requirements. Most Meter RESetters are Made to order and are not returnable. Please verify with the factory that the model number you have configured is available and meets your requirements. 1112 800.292.2737 FAX 800.832.9296 sales@aymcdonald.com aymcdonald.com 11

718 SERIES Horizontal Style Resetters 1 1 2" & 2" No Bypass 1" Copper cross tube is standard for no bypass setters. The A.Y. McDonald 718 1 1 2" and 2 oval flanged horizontal resetter allows you to reset a meter incorporating an inlet or outlet shut off valve or check valve while offering several height options. It also offers bypass options and several options for taps to incorporate pressure relief valves or sampling valves before or after the meter. Depending on valve configurations, minimum heights may vary. Brass eye holes accept 1" iron pipe or 1" PVC. INLET Meter Flange OUTLET Meter Flange For Tandem Series 718 Series Style Meter Size Meter Height Inlet Outlet Meter Connections 718 = Standard No Bypass 6 6 = 1 1 2" 7 = 2" Lower heights may be available contact factory. Model 718618WD 18 15" 18" 21" 24" For special heights, contact factory. Minimum height may apply based on configuration of setter. W D D = Angle dual check valve E = Angle dual check valve with 1" tap in cap with 1" NPT plug assembly F = Angle dual check valve with 1 1 2" tap in cap with 1 1 2" NPT plug assembly G = Angle dual check valve with 2" tap in cap with 2" NPT plug assembly N = Flanged elbow T = Flanged tee with 2" plug in top of tee for access W = Angle lockwing ball valve 758 Series Tandem Setter Example 758618WD Tandem resetters are supplied with 610M adapters and S tube. Please specify device length and threads when ordering. Not all combinations available, contact factory with your requirements. Most Meter RESetters are Made to order and are not returnable. Please verify with the factory that the model number you have configured is available and meets your requirements. 12 800.292.2737 FAX 800.832.9296 sales@aymcdonald.com aymcdonald.com 1112

INLET Meter Flange OUTLET Meter Flange 718 SERIES Horizontal Style Resetters 1 1 2" & 2" With Bypass The A.Y. McDonald 718 1 1 2" and 2" oval flanged horizontal resetter allows you to reset a meter incorporating an inlet or outlet shut off valve or check valve while offering several height options. It also offers bypass options and several options for taps to incorporate pressure relief valves or sampling valves before or after the meter. Depending on valve configurations, minimum heights may vary. Brass eye holes accept 1" iron pipe or 1" PVC 2" Meter flanges have slotted bolt holes to fit 1 1 2" or 2" meters Two drop in flange gaskets furnished. Two meter support brackets furnished. 1¼" bypass includes a 1" x 1" x 1 1 4" ball valve. Resetter with bypass requires a check valve or ball valve on outlet Cross sized resetters available, contact factory. 718 For Tandem Series B 6 Series Bypass Meter Size Meter Height Inlet Outlet Meter Connections 718 6 = 1 1 2" 7 = 2" B = Low bypass R = High Offset Model 718B618WD 18 12" 15" 18" 21" 24" For special heights, contact factory. Minimum height may apply based on configuration of setter. W D D = Angle dual check valve E = Angle dual check valve with 1" tap in cap with 1" NPT plug assembly F = Angle dual check valve with 1 1 2" tap in cap with 1 1 2" NPT plug assembly G = Angle dual check valve with 2" tap in cap with 2" NPT plug assembly N = Flanged elbow T = Flanged tee with 2" plug in top of tee for access W = Angle lockwing ball valve 758 Series Tandem Setter Example 758618WD Tandem resetters are supplied with 610M adapters and S tube. Please specify device length and threads when ordering. Setter Height B = Low Bypass 6.50 R = High Ofset Bypass Not all combinations available, contact factory with your requirements. 6 1 2 to right of meter Most Meter RESetters are Made to order and are not returnable. Please verify with the factory that the model number you have configured is available and meets your requirements. 1112 800.292.2737 FAX 800.832.9296 sales@aymcdonald.com aymcdonald.com 13

Gaskets METER MODEL DESCRIPTION SIZE 18G1 5/8" Rubber 5/8" 18G1F 5/8" Fiber 5/8" 18G1L 5/8" Waxed Leather 5/8" 18G2 3/4" Rubber 5/8" x 3/4" or 3/4" 18G2F 3/4" Fiber 5/8" x 3/4" or 3/4" 18G2L 3/4" Waxed Leather 5/8" x 3/4" or 3/4" 18G4 1" Rubber 1" 18G4F 1" Fiber 1" 18G4L 1" Waxed Leather 1" Two drop in flange gaskets furnished. Two meter support brackets furnished. METER MODEL DESCRIPTION SIZE 18G6 1 1 2" FlangeRubber 1 1 2" 18G7 2" FlangeRubber 2" 4620G 1 1 2" RoundRubber 1 1 2" 4620G 2" RoundRubber 2" 2" Meter Flanges have slotted bolt holes to fit 1 1 2" or 2" meters. Meter Bushings Changes thread size only 10J12 Converts 5/8" meter spud to 5/8" x 3/4" meter spud two pieces required per meter 10J45 Converts 1" meter spud to 1 1 4" meter spud two pieces required per meter Meter Adapters Converts meter size and laying length 10J12KIT Converts 5/8" meter spud to 5/8" x 3/4" meter spud two pieces per bag 710J13 Converts 5/8" meter to 3/4" meter two pieces required per meter 710J46KIT Converts 1" meter to 1 1 2" flanged meter size and length two pieces per kit 710J13KIT Converts 5/8" meter to 3/4" meter two pieces per kit 710J47 Converts 1" meter to 2" flanged meter size and length two pieces required per meter 710J14 Converts 5/8" meter to 1" meter two pieces required per meter 710J47KIT Converts 1" meter to 2" flanged meter size and length two pieces per kit 710J14KIT Converts 5/8" meter to 1" meter two pieces per kit 710J23 710J24 Converts 5/8" x 3/4" meter to 3/4" meter one piece required per meter Converts 5/8" x 3/4" meter to 1" meter two pieces required per meter 710J24KIT Converts 5/8" x 3/4" meter to 1" meter two pieces per kit 710J34 Converts 3/4" meter to 1" meter two pieces required per meter 710J34KIT Converts 3/4" meter to 1" meter two pieces per kit 710J67 Converts 1 1 2" flanged meter to 2" flanged meter size and length two pieces required per meter two bolts included 710J67KIT Converts 1 1 2" flanged meter to 2" flanged meter size and length two pieces per kit four bolts included 710J67DH Converts 1 1 2" flanged meter to 2" flanged meter size and length two pieces required per meter Slotted holes for 1 1 2" or 2" meters does not include bolts and nuts 710J77DHX2 X1.75 Converts 2" x 15.25" flanged meter to 2" x 17" flanged meter size and length one piece required per meter. Slotted holes for 1 1 2" or 2" meters does not include bolts and nuts 710J46 Converts 1" meter to 1 1 2" flanged meter size and length two pieces required per meter 6121 Meter support bracket 1 1 2" and 2" Meter Dimensions Oval Flange Meter Size 5/8" 5/8" x 3/4" 3/4" 1" 1 1 2" 2" AMeter Threads 3/4" 1" 1" 1 1 4" 1 1 2" 2" BLay Length 7 1 2" 7 1 2" 9" 10 3 4" 13" 17" A.Y. M c Donald Spacing* 7 13 16" 7 13 16" 9 5 16" 11 3 32" 13.38" 17.38" *Allows for meter and two gaskets. Note: A.Y. McDonald uses the above standards for typical meter applications. If your application is special or in question, you should always measure the meter as shown above. Other meter lay lengths must be specified. An additional 3/8" is added to top spacing to allow for gaskets: Standard 2" top spacing = 17 3 8". 14 800.292.2737 FAX 800.832.9296 sales@aymcdonald.com aymcdonald.com 1112

Tandem Options All A.Y. M c Donald tandem copper setters are designed to provide the user with the option of placing an auxiliary device in addition to a water meter in a space as small as 18" in diameter (see Table I). The auxiliary device could be a pressure regulator, pressure relief valve, backflow preventer, etc. Table I shows typical lay lengths available for these devices. Other lengths can be provided. Contact our customer service department for details. Standard centerline spread for 5/8", 5/8" x 3/4", 3/4" meters is 7". 1" meter is 9". Tandem meter setter S bar (4619Ssize) and brass adapters (74619size) come as standard when ordering tandem resetters, but are also available separately (see below). Contact factory. Resetters with crossover meter sizes are available, contact factory. TABLE I Meter Size Device Minimum Length Recommended (FNPT x FNPT) Inside Pit Diameter 5/8" 4" to 5" 18" 5/8" x 3/4" 4" to 5" 18" 3/4" 4" to 5" 20" 1" 5" to 6" 21" Tandem "S" Bar 4619S 5/8" for use with 5/8" meter tandem 4619S 5/8" x 3/4" for use with 5/8" x 3/4" meter tandem 4619S 3/4" for use with 3/4" meter tandem Above items for use with 4"5" device 4619S 1 for use with 1" meter tandem Above item for use with 5"6" device "S" Bar Adapter Two pieces required per device 74619 5/8" (5/8" meter x 3/4" NPT) 74619 3/4" (5/8" x 3/4" or 3/4" meter x 3/4" NPT) 74619 1" (1" meter x 1" NPT) 7" 9" Spread for 5/8", 5/8"x 3/4" and 3/4" Meters Spread for 1" Meters Note: Special length cross tubes and inverted tandem cross tubes are available, contact factory. Sectional View ASSE 1024 Angle Meter Valve Ball Style Angle Dual Poppet Check Valve Single Poppet Check Valve Double wall flange thickness Test Valve in Tubing Copper Tube Flange Meter Threads 1112 800.292.2737 FAX 800.832.9296 sales@aymcdonald.com aymcdonald.com 15

A.Y. McDonald Mfg. Co. is a leading manufacturer of Waterworks Brass, Plumbing Valves, Pumps and Water Systems, and High Pressure Gas Valves and Meter Bars. The Company has distinguished itself with a proud tradition of quality and reliability since its founding in 1856. The mission of A.Y. McDonald Mfg. Co., in the words of our founder, is to make good products and sell them honestly. We, the stockholders and employees, accomplish this by extending the McDonald family culture through excellent customer service and by focusing on our customers needs. WARNING: It is unlawful in CALIFORNIA & VERMONT (effective 1/1/2010); MARYLAND (effective 1/1/2012); LOUISIANA (effective 1/1/2013) and the UNITED STATES OF AMERICA (effective 1/4/2014) to use any product in the installation or repair of any public water system or any plumbing in a facility or system that provides water for human consumption if the wetted surface area of the product has a weighted average lead content greater than 0.25%. This prohibition does not extend to service saddles used in California, Louisiana or under USA Public Law 111380. 11/12 More than a brand. We re a family. aymcdonald.com 18002922737 sales@aymcdonald.com