INSTRUCTION MANUAL. Handy Polaris



Similar documents
OxyGuard. Dissolved Oxygen Probe

User Guide. Heavy Duty Dissolved Oxygen Meter. Model

Milwaukee USER MANUAL. Milwaukee. Smart DO Meter PORTABLE DISSOLVED OXYGEN METER MODEL: SM600. Authorized Dealer: ISMIL600 11/01

DISSOLVED OXYGEN PROBE

Milwaukee USER MANUAL

User's Guide. ExStik DO600. Dissolved Oxygen Meter RECALL. Dissolved Oxygen DO600

User's Manual. Heavy Duty Dissolved Oxygen Meter Model

Portable Waterproof ph/dissolved Oxygen Meter

Instruction Manual HI Portable Waterproof Microprocessor Dissolved Oxygen Meter

Oxygen Measurement. with CONTENTS

Relative Humidity Calibration Kit

Instruction Manual DO 110. Hand-held Dissolved Oxygen Meter with RS 232C. 68X Rev. 0-11/05. Technology Made Easy...

MODEL 970 DISSOLVED OXYGEN METER OPERATING MANUAL

Portable Waterproof Dissolved Oxygen Meter

YSI Meter Protocol: Specific Conductivity, ph, & Dissolved Oxygen

FARMEX HT-PRO OPERATING INSTRUCTIONS PORTABLE MOISTURE AND TEMPERATURE TESTER FOR BALED HAY

DISSOLVED OXYGEN METER Model : DO-5509

Direct Measurement Method Method to 20.0 mg/l (or 0 to 200% saturation) O 2 Clark-type Amperometric Sensor

User Guide Dissolved Oxygen Probes

Thermistor Thermometer MODEL NO

Professional Thermohygrometer

Operating Instructions Bedienungsanleitung Mode d'emploi Instrucciones de manejo Istruzioni d'uso

Dissolved Oxygen Sensors

Bluelab Soil ph Meter Instruction Manual

User's Guide. Pinless Moisture Meter. Model MO257

STANDARD OPERATING PROCEDURE Dissolved Oxygen Measurement, Meter Calibration and Maintenance

Pro1030 USER MANUAL. English

MODEL 430 PORTABLE ph/conductivity METER OPERATING MANUAL

Instruction Manual Temp 4/5/6 Temperature Meter Series

User Guide. Temperature and Humidity Datalogger. Model 42280

6 H2O + 6 CO 2 (g) + energy

GSM Alarm System User Manual

User's Guide. Digital Psychrometer. Model RH390. F C WBT Dew Point MAX MIN

Instruction Manual HI Refractometer for Refractive Index and Brix Measurements

Trace Dissolved Oxygen Sensor

Operators Manual BHT-2. Advanced Baler-Mounted Hay Moisture Tester ENGLISH. DOCU-M0160 Rev-1.1

Hygro-Thermometer + InfraRed Thermometer Model RH101

digital fever alert ear thermometer suitable from birth instruction manual

mg/l YSI Model 85 Handheld Oxygen, Conductivity, Salinity, and Temperature System Operations Manual

Galvanic Parts Per Million Dissolved Oxygen Systems

DO-6. Dissolved Oxygen Meter. Newport Electronics, Inc. Operator s Manual

ExStik TM ph Waterproof Meters

Care and use guide. Contents. a handy solution made easy. page

OCSM Series. High Resolution Digital Crane Scale. User Guide

Thermocouple Thermometer Models

Measuring ph in Water or CaCl2 Using a ph Meter. Compiled by Darren Murray, June 30, 2011 TABLE OF CONTENTS OVERVIEW 3

Chloride and Salinity

HOBO Dissolved Oxygen Logger (U26-001) Manual

EK908FHL - Thermostat for floor heating

Operator Quick Guide EC SENSOR

High Res Mini Cam Stick Spy Hidden Camera and Recorder (HGUMCAM02)

Instruction Manual HI Refractometer for Sucrose Measurements

Operations Manual. YSI 550A Dissolved Oxygen Instrument

User Manual da Vinci 2.0 Duo. da Vinci 2.0 Duo User Manual

ELECTROCHEMISTRY. BOECO ELECTRODES The electrodes are not included with the ph meters and have to be ordered separately:

User Guide. ExStik TM ph (PH100 & PH110) and ORP (RE300) Waterproof Series Pens. Patent Pending

EASIDEW PORTABLE HYGROMETER INSTALLATION, OPERATION AND MAINTENANCE MANUAL

4-Channel Thermometer / Datalogger

INSTRUCTION MANUAL. NC-500 NETcat Pro Wiring Tester

YSI Model 5000 YSI Model Dissolved Oxygen Temperature. Operations Manual

Lead Testing and On Site Calibration for Water Testing Detection Range: 2 100ppb

INVERTER GENERATOR OWNER S MANUAL FOR YOUR SAFETY PLEASE READ THESE INSTRUCTIONS CAREFULLY AND RETAIN THEM FOR FUTURE USE.

MAKING MODERN LIVING POSSIBLE. living connect. Installation and User Guide. Danfoss Heating Solutions

Dissolved Oxygen Probe (Order Code DO-BTA or DO-DIN)

EDGE 800. quick start manual TOUCHSCREEN GPS-ENABLED BIKE COMPUTER

PLL2210W LED LCD Monitor

Transmitter Interface Program

IN-OUT Thermometer with Cable Free Sensor and Clock

EXERGEN. English. TemporalScanner TM. Accurate Temperature with a Gentle Forehead Scan. Operators Manual for TAT-5000

New GSM Alarm System. User s Manual. Profile For a better understanding of this product, please read this user manual thoroughly before using it.

Lexmark E260, E260d, and E260dn Series. Maintenance Guide

INSTRUCTION MANUAL DTH Fax: (503)

Care and use guide. Contents. a handy solution made easy. page

RS Stock No Instruction Manual RS-1340 Hot Wire Anemometer

E E V R E - R S - O S L O A L R

Instruction Manual FL

ph 200 ph-/redox-/temperature Meter Operating instructions

SC 7000 and SC 9000XL Patient Monitors SC 9000XL Monitor 12in (30.5cm) Display Service Manual Supplement Two

ThermoScan Instant Thermometer IRT 1020 Type 6005 Home Model

EDGE 800. quick start manual TOUCHSCREEN GPS-ENABLED BIKE COMPUTER

MAKING MODERN LIVING POSSIBLE. living connect. Installation and User Guide. Danfoss heating

Troubleshooting Salt Generators

- Do not immerse cords, pump or any electrical wire or device in water or other liquid.

EnergySmart monitor user instructions

Carpet Washer. vax.co.uk VRS5W. Vax Careline: (UK) (ROI) Vax model number: Version 1.0

Tassimo The Art of the Perfect Cup

OCS-S High Resolution Digital Crane Scale

Microwave Meter. Instruction Manual

Model MC-82 Dissolved Oxygen Temp. Meter Handbook Version : 1.0

quick start manual MULTISPORT GPS TRAINING DEVICE

Resolution selectable from 0.01 and ph. Range ph. Accuracy ± ph

Please read and keep these instructions. Run water through your machine before first use

Optical Ranging System (BORS )

USER'S GUIDE NUSCAN 2100 Series

Professional Plus. Calibration Tips

RS DIGITAL THERMOMETER

Back-UPS Pro 1300/1500 Installation and Operation

Sensi TM. Wi-Fi Programmable Thermostat MANUAL OPERATION. Version: March Emerson Electric Co. All rights reserved.

da Vinci 1.0 User Manual

Transcription:

INSTRUCTION MANUAL Handy Polaris

**This page is left blank**

Table of Contents 1 General...4 2 Setup...5 2.1 Calibrate...5 2.2 Set Salinity...5 2.3 User Interface...5 2.3.1 Language...5 2.3.2 Temperature Units...5 2.3.3 Oxygen Units...6 2.3.4 Auto shutdown...6 2.3.5 Light intensity (display backlight)...6 2.4 Information...6 2.5 Status list...6 3 Maintenance...7 3.1 Battery exchange...7 3.2 Probe Renovation...7 4 Technical Support...9 4.1 Returning Equipment for Repair...9 5 Technical Specification...10 Page 3 of 12

1 General The OxyGuard Handy Polaris is a hand-held battery powered dissolved oxygen (DO) meter. It measures mg/l (ppm), % saturation, temperature, has salinity compensation and automatic compensation for temperature and barometric pressure. The probe is fully field serviceable. The instrument can withstand wet conditions and being dropped in the water! The Polaris is very easy to use. The arrow buttons allow you to move round in the actual display, the "OK" button moves to the next level and the "ESC" button moves back. To turn the Polaris on or off hold the on/off button depressed for 3 seconds. The instrument will turn off automatically if no button is pressed for the auto shutdown time. Use the arrow buttons to select which parameter is shown in large figures. If the Polaris shows a setup display and you want to measure, press "Esc" one or more times to make it show the measurement display. If an error condition occurs then "Error", "Warning" or "Calibrate" will blink in the display. The Polaris will show more information in the status list window. See Status List. To measure DO, turn the Polaris on and immerse the probe in the water. If there is no flow past it move the probe slowly 5 10 cm/sec is enough. When you are finished using the Handy rinse the probe in clean water. Wipe the meter dry if it is wet. To calibrate, or check the calibration, make sure the probe has the same temperature as the air. Store the Handy in its pouch at a stable temperature overnight and check the reading in the morning. In water the probe adjusts to change in temperature in a minute or two, but in air it can take an hour. Page 4 of 12

2 Setup From measurement press "OK" to reach the setup menu (if necessary press "Esc" repeatedly as needed to reach measurement). The setup menu contains the following: 2.1 Calibrate To calibrate, or check the calibration, make sure the probe has the same temperature as the air. The meter should show between 100 & 101% sat with the probe in air (the temperature must be steady). Variations from 100.5 can be due to changes in humidity or changes in the actual oxygen concentration of the air. If calibration seems to be needed wipe the membrane carefully and check again. To calibrate select Calibrate and press "OK". Progress is shown on the display, which will also tell you if anything is wrong. When "Calibration done" is shown press "OK". If changing temperature or similar prevent correct calibration you can "force" calibration by holding "OK" depressed when "Calibrate - Please wait" is shown. The result will not necessarily be precise "Calibrate" will blink in the display when making measurements. Recalibrate under more stable conditions when possible. 2.2 Set Salinity Use this function to set the salinity of the water you measure in. Set the tens figure first using the arrow buttons. Press "OK" to go to units set this figure and press "OK" again. "New salinity" and the new setting appears in the display. Press "OK" to confirm and then "Esc" to measure. NB to go from units to tens press "Esc". 2.3 User Interface This permits the following to be set:language, Temperature units, Oxygen units, Auto shutdown time, Light intensity (backlight) NB "> <"indicates the current setting. 2.3.1 Language Select Language and press "OK" to see which languages are found on your instrument. Select the desired language and press "OK" to change the language, or press "Esc" to exit. 2.3.2 Temperature Units You can choose between Celsius C or Fahrenheit F. Use the arrow buttons, "OK" and "Esc" as with the other parameter. Page 5 of 12

2.3.3 Oxygen Units You can choose between mg/l and PPM 2.3.4 Auto shutdown The meter shuts down if no buttons are pressed after 2, 5, 10, 15 or 30 minutes as set. The factory default is 5 minutes. A long setting gives shorter expected battery life. If "Off" is chosen the Polaris MUST be switched off using the on/off button. 2.3.5 Light intensity (display backlight) You can choose "Low" (default value), "Medium" or "High". Frequent use of high level backlight will reduce the battery lifetime significantly. 2.4 Information This shows the firmware version and the serial numbers for the probe and instrument. 2.5 Status list This menu only appears if an error condition exists. Selecting this and pressing "OK" will display a list of error conditions. For more information and help select the desired item and press "OK". Press "Esc" several times to return to the measurement display. Page 6 of 12

3 Maintenance A message in the display will inform you when probe renovation is needed, otherwise just calibrate, and keep the probe clean. 3.1 Battery exchange Use the tool to unscrew the rear plate. The battery can then easily be exchanged. Take care not to disturb the ribbon cables. PLACE THE BATTERY IN THE CUT-OUT IN THE PC BOARD - do NOT put it on top of the print. Make sure you tighten the rear plate properly! The tool is used to open the rear plate Insert battery here 3.2 Probe Renovation Do NOT do this unless a message in the display tells you so. See the drawings. NB. treat the electrolyte as concentrated salt water. Clean the probe. Pull off the membrane protector and unscrew the cap. Rinse the probe. Clean off any loose white deposits from the anode with the brown plastic scouring pad provided. Clean the cathode with the pad if needed. The cathode MUST NOT BE POLISHED. Unscrew the ring from the cap and discard the used membrane and O-ring. Clean the cap and ring and dry thoroughly. Place a new O-ring in the cap, then a membrane over the O-ring. Page 7 of 12

Screw the ring in place. Tighten fairly tightly, but the membrane must not wrinkle. If this happens try again with a new membrane and O-ring. An O-ring can only be used once. Fill the cap with type 1 electrolyte and screw it slowly onto the probe. Excess electrolyte will dribble from the thread. Calibrate the probe. Re-calibrate after a few hours, since the probe will take a little time to settle down after renovation. Page 8 of 12

4 Technical Support Technical Support is available by phone, fax, or email, the details of which are shown below. Phone: +44 (0) 1726 879800 Fax: +44 (0) 1726 879801 Email: techsupport@partech.co.uk Website: www.partech.co.uk To enable us to provide quick and accurate technical support please have the following information ready when you contact us: Serial Number or original purchase details Sensor Type, and Serial Number Application details Description of fault 4.1 Returning Equipment for Repair If equipment needs to be returned to Partech for repair or service the following address should be used: SERVICE DEPARTMENT PARTECH (ELECTRONICS) LTD CHARLESTOWN ST AUSTELL CORNWALL PL25 3NN UNITED KINGDOM Please include the following information with the returned equipment. Also ensure that sensors are adequately protected for transportation (Advice on packing can be provided by our service department). Contact name and phone number Return address for equipment Description of fault or service required Any special safety precautions because of nature of application Page 9 of 12

5 Technical Specification Operating Conditions:...Probe: -5ºC to + 45ºC, Meter: -20ºC to +60ºC Waterproof to max 5m depth short-term Measuring Range...0 to 60.0ppm (mg/l) and 0-600%sat Temperature Range...-5ºC to + 45ºC Salinity Compensation...0-59 ppt salinity (manually set) Accuracy:...Typically better than +/- 1 digit measured value +/- 1 digit Repeatability:...Typically better than +/- 0.5% of value Accuracy, Temperature:...+/-0.2ºC Self-check of:...probe, meter, cable, battery Useful battery life:...approx. 2 years with 1 hour use per day 5 months with 8 hours use per day Battery:...9V E-BLOCK, 6LR61, 6F22, MN1604 Page 10 of 12

**This page is left blank**

P artec h (E lec tronic s ) Ltd C harles town, S t Aus tell, C ornwall P L25 3N N, UK T: +44 (0) 1726 879800 F : +44 (0) 1726 879801 E : info@ partec h.c o.uk www.partec h.c o.uk