Short-circuit current rating (SCCR) of. industrial control panels. NEC Article 409 and UL 508A



Similar documents
Guidelines on the Short Circuit Current Rating for Industrial Control Panels

Validity 1. Improvements in STEP 7 2. Improvements in WinCC 3 SIMATIC. Readme. Programming and Operating Manual

Validity 1. Installation 2 SIMATIC. WinCC flexible Tag simulator Update 1. Readme

Simplified Guide To Understanding Short-Circuit Current Rating FIND IT, FIX IT, FORGET IT

UL guidelines, chapter 6.2 / 6.3 Motor Branch Circuits acc. to UL

Creating the program. TIA Portal. SIMATIC Creating the program. Loading the block library. Deleting program block Main [OB1] Copying program blocks

UL 508A Industrial Control Panels Power Distribution and Control. Lunch & Learn Training Eaton Corporation. All rights reserved.

COMOS. Lifecycle COMOS Snapshots. "COMOS Snapshots" at a glance 1. System requirements for installing "COMOS Snapshots" Database management 3

SIMATIC. ET 200S distributed I/O Digital electronic module 8DO DC24V/0.5 A (6ES7132-4BF00-0AA0) Preface. Properties 1. Diagnostics 2.

WinCC Runtime Professional Readme SIMATIC HMI. WinCC V11 SP1. Readme WinCC Runtime Professional. Special considerations for Windows 7.

Performing an automated installation

DANGER indicates that death or severe personal injury will result if proper precautions are not taken.

DB Administration COMOS. Platform DB Administration. Trademarks 1. Prerequisites. MS SQL Server 2005/ Oracle. Operating Manual 09/2011

Visualization SIMATIC. Visualization. Present sample project. HMI configuration. Insert HMI device from libraries 3. Configuring HMI connection 4

SUBJECT: How to wire a motor starter Number: AN-MC-004 Date Issued: 2/08/2005 Revision: Original

CPU PN/DP: Configuring an ET. 200S as PROFINET IO device SIMATIC. PROFINET CPU PN/DP: Configuring an ET 200S as PROFINET IO device

SIMATIC. Process Control System PCS 7 Configuration Symantec Endpoint Protection (V12.1) Preface 1. Virus scanner administration 2.

Documentation for. KL2602 and KL2622. Two-channel Relay Output Terminals for 230 V AC / 30 V DC. Version: 1.4 Date:

Information Server Documentation SIMATIC. Information Server V8.0 Update 1 Information Server Documentation. Introduction 1. Web application basics 2

Circuit Breakers Supplementary Protectors Manual Motor Controllers

Mission Critical Data Center Systems

SIMATIC. ET 200S distributed I/O Digital electronic module 8DI DC24V (6ES7131-4BF00-0AA0) Preface. Properties 1. Diagnostics 2.

Bussmann. All-In-One Module. Bussmann Power Module Switch. How to configure Part Numbers: Step 1: Select Switch Amperage 1

Patch management and security. updates SIMATIC. Process Control System PCS 7 Patch management and security updates. Preface 1

LOGO! LOGO! App V.10. LOGO! app 1. Making basic settings and establishing a connection to LOGO! Using the device overview 3. Creating controls 4

SIMATIC S Getting Started for First Time Users. Order No.: 6ZB5310-0NC02-0BA0 04/2007 A5E

Sentron Series Circuit Breakers

DANGER indicates that death or severe personal injury will result if proper precautions are not taken.

Validity 1. Improvements in STEP 7 2. Improvements in WinCC 3. Simatic. Readme. Readme

SINAMICS drives SINAMICS DCM. DC converters from 6 kw to 2500 kw for variable-speed direct-current drives. Load-balanced control application

Creating the project and hardware. TIA Portal. SIMATIC Creating the project and hardware. Introduction to the TIA Portal 1. Creating a project

misconceptions about arc-flash hazard assessments

Commercial/Industrial Electricity

Short Circuit Current Calculations

SIMATIC. SIMATIC Logon. User management and electronic signatures. Hardware and Software Requirements. Scope of delivery 3.

Circuit Breakers. Next Generation of Protection Capabilities

Electronic overload relay EF65, EF96 and EF146

Vilter motor starter solutions The NEW industry standard in motor starter packages

SIMATIC. WinCC V7.0. Getting started. Getting started. Welcome 2. Icons 3. Creating a project 4. Configure communication 5

Buck - Boost Transformers

SIMATIC NET Industrial Ethernet switches MM900 media modules for SCALANCE XR-500M

SIMATIC. ET 200S distributed I/O 2AO I ST analog electronic module (6ES7135-4GB01-0AB0) Preface. Properties 1. Parameters 2.

Terminal Blocks & Power Distribution Terminal Blocks. Make your connection

Electronic overload relay EF19 and EF45

Product Description Full Voltage Starting Electric Fire Pump Controllers FTA1000

HPS Universal. Single and Three Phase Potted. Buck-Boost Transformers. Buck-Boost Applications & Standard Specification... 80

Using Murrelektronik MICO Modules to Create Low Voltage Limited Energy Circuits in Industrial Control Panels according to UL508A.

Data Center Power Overload Protection: Circuit breakers and branch circuit protection for data centers

Data Bulletin Variable Frequency Drives and Short-Circuit Current Ratings

Arc Flash Avoidance and its Application to Overhead Traveling Cranes

SURGE PROTECTIVE DEVICES (SPDs) LOW VOLTAGE AC INTEGRATED SURGE PROTECTION FOR ELECTRICAL DISTRIBUTION SYSTEMS SECTION 16671A SECTION 16671A

Application Switchgear for industrial and commercial applications. U e V AC 230/ (per pole)

5SV Residual Current Protective Devices

Engineering Series Ratings: Is It Practical?

Power Distribution & Terminal Blocks

CONDUCTOR SHORT-CIRCUIT PROTECTION

Low Voltage Fuses For Motor Protection

SIMATIC HMI. WinCC flexible 2008 Getting Started - First-Time Users Getting Started. Printout of the Online Help 06/2008 A5E

TECHNICAL SUPPORT MANUAL 3 Phase Air Conditioner Component R2A3**GHR

CIRCUIT BREAKER INTERRUPTING CAPACITY AND SHORT-TIME CURRENT RATINGS

How can a charging station for electric vehicles be set up simply and safely?

ABR Brake Rectifier Instruction Manual

Current Transformers

MCC Ratings. Voltage Rating

HP UPS R1500 Generation 3

Arc Flash Hazards. Electrical Hazards. Dan Neeser Field Application Engineer Electrical Hazards 2/18/2015. Shock.

Getting Started - SINAMICS Startdrive. Startdrive. SINAMICS Getting Started - SINAMICS Startdrive. Introduction 1

Operating instructions Diffuse reflection sensor with background suppression O1D101 O1D / / 2012

Unified requirements for systems with voltages above 1 kv up to 15 kv

MTE SERIES RLW. World REACTORS USER MANUAL PART NO. INSTR 030 REL MTE Corporation

Modan 3000 ADVANCED TECHNOLOGY, INDUSTRIAL GRADE MOTOR CONTROL CENTER. Systems Products and Services. Motor Control Centers Modan 3000

DRM75A 230V 20/100A DIN rail single phase two wire energy meter

History and Overview. Manual Motor Protectors & Combination Motor Controllers

ADM1TE 5/30A DIN rail single phase two wire energy meter

Model 1756 Test Lead Kit

SIMATIC. S7 300 PLC CPU 317T-2 DP: Controlling a virtual axis. Introduction. Preparation. Learning units 3. Further information 4.

ELECTRICAL CONTRACTORS THE UNIVERSITY OF TENNESSEE KNOXVILLE, TENNESSEE SECTION PAGE 1

Owner s Manual. For Automatic Transfer Switch Amp, Service Entrance/Non-Service Entrance

Product Description Primary Resistance Starting Electric Fire Pump Controllers FTA1500

Permissible ambient temperature Operation Storage, transport

Installation Instructions

SECTION VARIABLE FREQUENCY DRIVES

BT300 HVAC Drives Conventional Bypass (C-Bypass) Options

Wiser Panel Meter, Model Number WISERCTPM200 Installer s Guide

Configuration limits for products of the SIMATIC NET PC Software V12 SIMATIC NET. Configuration limits for products of the SIMATIC NET PC Software V12

8146/5 Series Breaker Panelboards

3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & Instructions For Installation, Operation & Maintenance

The HVAC SOLUTION DELIVERING POWER...SAVING ENERGY


CoolWave r 2 Phase Control Board and Cable Replacement Kits

SINAMICS G130. Braking Module / braking resistor. Operating Instructions 05/2010 SINAMICS

Submit shop drawings for equipment provided under this section Shop drawings shall indicate:

MEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV

Reverse-feed applications for circuit breakers

Electronic Trip Circuit Breaker Basics Circuit Breaker Application Guide Class 0600

PowerFlex 700S and 700H Frame 12 DC Bus Connector Kit

..OR How To Protect your 3-Phase Equipment Investment with 3-Phase Monitors from Time Mark...

Mini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protection

Server Technology, Inc.

Transcription:

Short-circuit current rating (SCCR) of industrial control panels NEC Article 409 and UL 508A Short-circuit current rating (SCCR) of industrial control panels 1 Introduction 2 Overview of NEC Article 409 Overview of Supplement SB from the UL 508A standard 3 Basic steps for calculating the SCCR of a control panel 4 Flow chart for calculating the SCCR of a component 5 Reference Manual 02/2013 A5E31896849002A/RS-AA/001

Legal information Warning notice system This manual contains notices you have to observe in order to ensure your personal safety, as well as to prevent damage to property. The notices referring to your personal safety are highlighted in the manual by a safety alert symbol, notices referring only to property damage have no safety alert symbol. These notices shown below are graded according to the degree of danger. DANGER indicates that death or severe personal injury will result if proper precautions are not taken. WARNING indicates that death or severe personal injury may result if proper precautions are not taken. CAUTION indicates that minor personal injury can result if proper precautions are not taken. NOTICE indicates that property damage can result if proper precautions are not taken. If more than one degree of danger is present, the warning notice representing the highest degree of danger will be used. A notice warning of injury to persons with a safety alert symbol may also include a warning relating to property damage. Qualified Personnel The product/system described in this documentation may be operated only by personnel qualified for the specific task in accordance with the relevant documentation, in particular its warning notices and safety instructions. Qualified personnel are those who, based on their training and experience, are capable of identifying risks and avoiding potential hazards when working with these products/systems. Proper use of Siemens products Note the following: Trademarks WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems. The permissible ambient conditions must be complied with. The information in the relevant documentation must be observed. All names identified by are registered trademarks of Siemens AG. The remaining trademarks in this publication may be trademarks whose use by third parties for their own purposes could violate the rights of the owner. Disclaimer of Liability We have reviewed the contents of this publication to ensure consistency with the hardware and software described. Since variance cannot be precluded entirely, we cannot guarantee full consistency. However, the information in this publication is reviewed regularly and any necessary corrections are included in subsequent editions. Siemens AG Industry Sector Postfach 48 48 90026 NÜRNBERG GERMANY A5E31896849002A/RS-AA/001 P 02/2013 Technical data subject to change Copyright Siemens AG 2012. All rights reserved

Table of contents 1 Introduction... 5 2 Overview of NEC Article 409... 7 3 Overview of Supplement SB from the UL 508A standard... 9 4 Basic steps for calculating the SCCR of a control panel... 11 4.1 SB4.2 Determining the short-circuit current ratings (SCCR) of individual power circuit components...11 4.1.1 Basic: Device markings or component instruction sheets...11 4.1.2 Basic: Assumed short-circuit current rating...12 4.1.3 Basic: Tested combination of devices per UL508...13 4.2 SB4.3 - Use of current-limiting components...17 4.2.1 Current-limiting transformers...17 4.2.2 Current-limiting circuit breaker (per UL489)...18 4.2.3 Current-limiting fuses...19 4.3 SB4.4 SCCR calculation of the industrial control panel...21 5 Flow chart for calculating the SCCR of a component... 23 5.1 Calculating the SCCR value of a component...23 5.2 Calculating the SCCR with current-limiting feeder components...24 5.3 Calculating the SCCR of an industrial control panel...26 Reference Manual, 02/2013, A5E31896849002A/RS-AA/001 3

Table of contents 4 Reference Manual, 02/2013, A5E31896849002A/RS-AA/001

Introduction 1 Article 409 on Industrial Control Panels was added to the NEC in its 2005 edition. This Article requires all Industrial Control Panels to be marked with a short-circuit current rating. The short-circuit current rating (SCCR) requirements for UL 508A came into force in April 2006. These changes impact control panel builders, OEMs and end users in a number of different ways: The correct choice of power circuit components of a control panel Specification of preferred device manufacturers Design and marking of panels Correct installation and modification of control panels Siemens is committed to supplying best-in-class products and services to our customers. Siemens provides extensive product documentation to enable its customers to comply with NEC Article 409 and the changes in the UL 508A standard. Guide This document includes the following information: Overview of NEC Article 409 Overview of Supplement SB of the UL 508A standard with relevant examples Process flow charts Calculating the SCCR value of a component Calculating the SCCR with current-limiting feeder components Calculation of the SCCR value of a control panel Further information about UL/NFPA Underwriters Laboratories UL (http://www.ul.com) UL online certifications directory (http://www.ul.com/database) National Fire Protection Association NFPA (http://www.nfpa.org) Reference Manual, 02/2013, A5E31896849002A/RS-AA/001 5

Introduction 6 Reference Manual, 02/2013, A5E31896849002A/RS-AA/001

Overview of NEC Article 409 2 The NFPA 70: National Electrical Code includes Article 409 on the Construction of Industrial Control Panels operating at 600 volts or less. Section 409.2: definition of industrial control panels Section 409.2 defines an industrial control panel as: An assembly of two or more components In the power circuit, such as motor controllers, overload relays, fused disconnect switches, and circuit breakers In the control circuit, such as pushbuttons, signal lamps, selector switches, time-delay switches/relays, switches, control relays Or in a combination of the two circuits These components are mounted in an enclosure or panel with the associated wiring and terminals. The industrial control panel does not include the controlled equipment. Section 409.110 Section 409.110 requires a short-circuit current rating (SCCR) to be marked on all industrial control panels. This rating must be based on the rating of a listed and labeled assembly or on another approved method for determining the rating. It also includes a fine print note (FPN) reference to UL 508A Supplement SB as an example of an approved method for determining the SCCR that may be marked on the panel. Reference Manual, 02/2013, A5E31896849002A/RS-AA/001 7

Overview of NEC Article 409 8 Reference Manual, 02/2013, A5E31896849002A/RS-AA/001

Overview of Supplement SB from the UL 508A standard 3 Components in the power circuit UL508A is the safety standard for industrial control panels. NEC Article 409 references UL508A Supplement SB as an approved method for determining the SCCR of an industrial control panel. The specific method is outlined in Section SB4. The SCCR of the control panel is based on the SCCR of each component in the power circuit. The component with the lowest SCCR limits the SCCR of the entire panel. Paragraph SB4.2.1 and Table SB4.1 list the following components as part of the power circuit: Disconnect switches Branch circuit protective devices Fuseholders Load controllers Motor overload relays Receptacles Supplementary protectors Busbars Current meters Current shunts Switch units Terminals or power distribution blocks Paragraph SB3.2.1 states that the primary short-circuit protective device for the control circuit is also included in the calculation for the SCCR for the power circuit. Therefore, the SCCR of the overcurrent protective devices (except for supplementary protectors recognized according to UL1077 or sets of supplemental fuses recognized according to UL248-13) are included in calculation of the SCCR of the control panel. Control circuit components on the load side of these devices are not included in calculation of the SCCR. Reference Manual, 02/2013, A5E31896849002A/RS-AA/001 9

Overview of Supplement SB from the UL 508A standard 10 Reference Manual, 02/2013, A5E31896849002A/RS-AA/001

Basic steps for calculating the SCCR of a control panel 4 4.1 SB4.2 Determining the short-circuit current ratings (SCCR) of individual power circuit components SB4.2 Determining the short circuit current ratings (SCCR) of individual power circuit components using three possible methods. Based on device markings or component instruction sheets Based on assumed short-circuit current rating Based on tested combinations of devices per UL508 4.1.1 Basic: Device markings or component instruction sheets Most Siemens power control and circuit protection components include a standard short circuit rating on the front or side label. Example of marking on a 3RT contactor Figure 4-1 Rating plate Exception The short-circuit current rating of Siemens frequency converters is stated in the operating instructions or the relevant catalogs. The complies with the requirements of NEC Article 409 and is therefore entered in the relevant UL test reports. Reference Manual, 02/2013, A5E31896849002A/RS-AA/001 11

Basic steps for calculating the SCCR of a control panel 4.1 SB4.2 Determining the short-circuit current ratings (SCCR) of individual power circuit components Moreover, in the case of frequency converters that are protected with fuses, circuit breakers per UL489 or self-protected combination motor controllers per UL508 type E, the short-circuit current rating of the drive in conjunction with the line-side protective device is stated. 4.1.2 Basic: Assumed short-circuit current rating Based on the assumed short-circuit current rating per Table SB4.1 (see excerpt) Figure 4-2 Table SB4.1 Assumed maximum short circuit current rating for unmarked components (excerpt) 12 Reference Manual, 02/2013, A5E31896849002A/RS-AA/001

Basic steps for calculating the SCCR of a control panel 4.1 SB4.2 Determining the short-circuit current ratings (SCCR) of individual power circuit components 4.1.3 Basic: Tested combination of devices per UL508 To increase the short-circuit current rating of a device, an appropriate protective device must be connected on the line side of it. Which protective device is suitable is stated in the relevant UL test report of the device whose SCCR is to be increased. UL test report Example: A 3RT2015 contactor has a default value of 5 ka according to its rating plate. The UL test report states the protective devices with which the short-circuit current rating can be increased. Excerpt from the UL test report: Figure 4-3 UL test report excerpt Reference Manual, 02/2013, A5E31896849002A/RS-AA/001 13

Basic steps for calculating the SCCR of a control panel 4.1 SB4.2 Determining the short-circuit current ratings (SCCR) of individual power circuit components Download: certificates of compliance For switching devices, so-called certificates of compliance can be downloaded from the following link. This contains the contents of the UL test reports that are relevant for configuration. http://www.siemens.de/sirius/support Figure 4-4 Support: certificate download 1 Figure 4-5 Support: certificate download 2 14 Reference Manual, 02/2013, A5E31896849002A/RS-AA/001

Basic steps for calculating the SCCR of a control panel 4.1 SB4.2 Determining the short-circuit current ratings (SCCR) of individual power circuit components Figure 4-6 Support: certificate download 3 Figure 4-7 Support: certificate download 4 General information and relevant product documentation (including configuration manuals) relating to North America can be downloaded from the following link: www.siemens.de/uleuropa Reference Manual, 02/2013, A5E31896849002A/RS-AA/001 15

Basic steps for calculating the SCCR of a control panel 4.1 SB4.2 Determining the short-circuit current ratings (SCCR) of individual power circuit components Example The following examples shows a circuit breaker per UL489 in a feeder circuit and a tested combination per UL508 Type F. The circuit breaker has been tested and approved for 100 ka and the self-protected combination motor controller per UL 508 Type E has also been tested and approved for 65 ka. The combination shown below complies with 65 ka according to the UL rules. Figure 4-8 Example combination 16 Reference Manual, 02/2013, A5E31896849002A/RS-AA/001

Basic steps for calculating the SCCR of a control panel 4.2 SB4.3 - Use of current-limiting components 4.2 SB4.3 - Use of current-limiting components SB4.3 Adaptation of the available short-circuit current rating based on the peak let-through currents when using current-limiting devices in the feeder circuit. When short-circuit-current-limiting components are used in the feeder circuit, all components in the branch circuit must be rated for the peak let-through current of the short-circuit-currentlimiting components used in the feeder circuit. 4.2.1 Current-limiting transformers For branch circuits powered through a load transformer with an isolated secondary winding, the following applies to the SCCR on the secondary side: Transformer < 10 kva max. 5 ka on the secondary side, i.e. all devices on the secondary side must be rated for 5 ka or higher Transformer < 5 kva and max. 120 V max. 2 ka on the secondary side, i.e. all devices on the secondary side must be rated for 2 ka or higher All other transformers are not current-limiting, i.e. they have the same short-circuit current on the secondary and the primary side Reference Manual, 02/2013, A5E31896849002A/RS-AA/001 17

Basic steps for calculating the SCCR of a control panel 4.2 SB4.3 - Use of current-limiting components 4.2.2 Current-limiting circuit breaker (per UL489) To be able to use a circuit breaker as a current-limiting component in the feeder circuit, it must be marked "current limiting." In this case, the let-through currents of the circuit-breaker must be considered. The letthrough current can be obtained from the circuit breaker characteristic. Example The example shows that this circuit breaker lets through 22 ka during a 100-kA short circuit. The SCCR of the assembly is the breaking capacity of the circuit breaker in the feeder circuit under the following conditions: The SCCR of all individual components in the circuit is not lower than the peak let-through current of the circuit breaker in the feeder circuit. The breaking capacity of all branch circuit protective devices or the SCCR of all "combination motor controllers" is not lower than the breaking capacity of the circuit breaker in the feeder circuit. The SCCR of the assembly is the lowest breaking capacity of a branch circuit protective device connected on the load side of the circuit breaker in the feeder circuit or a "combination motor controller" if this is smaller than the breaking capacity of the circuit breaker in the feeder circuit. The SCCR value of the assembly is the lowest SCCR value of each branch circuit on the load side of the circuit breaker if the above conditions do not apply. 18 Reference Manual, 02/2013, A5E31896849002A/RS-AA/001

Basic steps for calculating the SCCR of a control panel 4.2 SB4.3 - Use of current-limiting components 4.2.3 Current-limiting fuses Only fuses from UL508A, Tab. SB4.2 may be used as current-limiting fuses. This table shows the relevant let-through currents (see column Ip x 10³). Figure 4-9 Table SB4.2 The SCCR of the assembly is the breaking capacity of the fuse in the feeder circuit under the following conditions: The SCCR of all individual components in the circuit is not lower than the peak letthrough current of the fuse in the feeder circuit. The breaking capacity of all branch circuit protective devices or the SCCR of all "combination motor controllers" is not lower than the breaking capacity of the fuse in the feeder circuit. The SCCR of the assembly is the lowest breaking capacity of a branch circuit protective device connected on the load side of the fuse in the feeder circuit or a "combination motor controller" if this is lower than the breaking capacity of the fuse in the feeder circuit. The SCCR of the assembly is the lowest SCCR of each branch circuit on the load side of the fuse if the above conditions do not apply. Reference Manual, 02/2013, A5E31896849002A/RS-AA/001 19

Basic steps for calculating the SCCR of a control panel 4.2 SB4.3 - Use of current-limiting components Examples The following two examples show a fuse as the feeder circuit protective device. The procedure described also applies if a circuit breaker per UL489 is used as the feeder circuit protective device. Example 1 SCCR value 35 ka because the circuit breaker is only suitable for 35 ka. The contactor and overload relay are protected by the fuse in the feeder circuit because 5 ka (SCCR contactor and overload relay) > 3 ka (let-through current of the fuse). Example 2 SCCR value 50 ka because the circuit breaker does not have a lower breaking capacity than the fuse. The contactor and overload relay are protected by the fuse in the feeder circuit because 5 ka (SCCR contactor and overload relay) > 3 ka (let-through current of the fuse). 20 Reference Manual, 02/2013, A5E31896849002A/RS-AA/001

Basic steps for calculating the SCCR of a control panel 4.3 SB4.4 SCCR calculation of the industrial control panel 4.3 SB4.4 SCCR calculation of the industrial control panel SB4.4 SCCR calculation of the industrial control panel with limitation to the lowest value of a component or a circuit according to SB4.2 or SB4.3. Example The first calculation is based on SB4.2 and looks as the individual SCCR values with which the components are marked or that appear on the list of unmarked components. Industrial control panel Components No. Power circuit Catalog no. 1 Circuit breaker ED63B050 2 Contactor 40FP32AA 3 Overload relays 48BSH3M10 4 Fuses on the primary side of the control transformer CC fuses Control circuit Catalog no. 5 Control transformer MT0050A 6 Control relay 3RH1122-1AK61 7 Terminal blocks 8WA1011-0DF21 8 Display lamp 52PC4E2 9 HAND-OFF-AUTO selector switch 52SA2CABA2 The components listed under control circuit do not have to be included in the SCCR calculation for the industrial control panel. The individual SCCR values of the individual power circuit components are as follows: No. Power circuit Catalog no. SCCR at 480 V 1 Circuit breaker ED63B050 25 ka 2 Contactor 40FP32AA 5 ka 3 Overload relays 48BSH3M10 5 ka 4 Fuses on the primary side of the control transformer CC fuses 200 ka Both the contactor and the overload relay have an SCCR of 5 ka at 480 V. If no further information is available, this industrial control panel would be marked with an SCCR of 5 ka at 480 V AC. Reference Manual, 02/2013, A5E31896849002A/RS-AA/001 21

Basic steps for calculating the SCCR of a control panel 4.3 SB4.4 SCCR calculation of the industrial control panel 22 Reference Manual, 02/2013, A5E31896849002A/RS-AA/001

Flow chart for calculating the SCCR of a component 5 5.1 Calculating the SCCR value of a component Figure 5-1 SB4.2 Reference Manual, 02/2013, A5E31896849002A/RS-AA/001 23

Flow chart for calculating the SCCR of a component 5.2 Calculating the SCCR with current-limiting feeder components 5.2 Calculating the SCCR with current-limiting feeder components Figure 5-2 SB4.3 (1) 24 Reference Manual, 02/2013, A5E31896849002A/RS-AA/001

Flow chart for calculating the SCCR of a component 5.2 Calculating the SCCR with current-limiting feeder components Figure 5-3 SB4.3 (2) Reference Manual, 02/2013, A5E31896849002A/RS-AA/001 25

Flow chart for calculating the SCCR of a component 5.3 Calculating the SCCR of an industrial control panel 5.3 Calculating the SCCR of an industrial control panel Figure 5-4 SB4.4 26 Reference Manual, 02/2013, A5E31896849002A/RS-AA/001