LUT Luminescence scanners: Seeing what no-one else can



Similar documents
W 27-2: The photoelectric switch series with expanded possibilities

W 36: Mastering complex tasks reliably

intelligent solutions

Photoelectric switches WLL 170(T), fibre-optic cables LL 3: flexible solutions with fibre-optic cable systems

W150: Miniature photoelectric switch series with completely integrated electronics

W 260: Standard photoelectric switch series for a broad range of applications

W 160: Miniature series for optimum solutions

W 2: Subminiature photoelectric switch series: extremely small and extremely strong

For accurate positioning in warehouse and conveying areas

Laser diffuse reflection light scanner with background suppression. Dimensioned drawing

W160T: With the smallest LED light spot

W 18-3: Incorporated application Know-how, expanded functionality, high level of equipment availability

sensors Miniature Sensors - S100 The universal miniature photoelectric sensor

Throughbeam photoelectric sensors. Dimensioned drawing. Electrical connection

Compact Sensors - S8 Series. Compact size and high performance for the most challenging detection applications

Color sensors CS8, CS8-1

Overview. Application Areas. DMP Position Finder

photoelectric highlights

SENSORS. Miniature Sensors - S3Z. Advanced line of miniature Asian style of photoelectric sensors mm background suppression

V180-2 M18 Cylindrical Photoelectric Sensor Series

L-LAS-TB-CL serie. laser light curtains for inline measuring tasks

Power Supply and Indicator Unit Type Fig. 1 Type Mounting and Operating Instructions EB 9539 EN

Photoelectric sensors V180-2, Photoelectric retro-reflective sensor, Standard optics

D ATA S H E E T. DT50 Laser class 1. Laser distance sensor

7 Lighting Technology

Photoelectric sensors W100, Photoelectric proximity sensor, energetic

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

Clear Glass Sensor. Ordering Information E3S-CR67/62. Optimum Sensor for Detecting Transparent Glass and Plastic Bottles

Operating instructions Diffuse reflection sensor. OJ50xx / / 2004

BOS 73K... BOS 74K...

Dimensional drawing. Connection type IME08-1B5NOZT0S IME08-1B5NSZT0S IME08-1B5POZT0S IME08-1B5PSZT0S. 3 x 0.14 mm². brn. L+ Schließer/ Öffner M.

Sturdy aluminium housing, anodized in blue Female connector for optical fiber (please order optical fiber separately) Mounting holes

Cross-beam scanning system to detect slim objects. 100 mm in

Digital Pressure Measuring Instrument MDR480

Color Mark Sensor with Red or Green LED E3S-VS

SENSORS. Fiber Optic Sensors - S70. Advanced fiber optic amplifiers for high speed and low contrast applications

Laserlyte-Flex Alignment System

Thru-Beam 80 to 320 mm 0.05 to 0.08 mm

LED red (-): Measuring value < lower tolerance threshold LED red (+): Measuring value > upper tolerance threshold. Page 1/6

ONLINE DATA SHEET. Contrast sensors KTM KTM-WP11181P

Tubular Analog model resolution: 0,5 mm (SLOW mode), 1 mm (FAST mode) Right angle Repeatibility: 0,7 mm Vdc

Bar code scanners CLV45x / CLV450 / Standard Density

fiber-optic sensors WLL180T, Fiber-optic photoelectric sensor

Speed Control Relays SX2

Electrical connection

Video surveillance camera Installation Guide

ONLINE DATA SHEET WT34-R220 W34 PRODUCT PORTFOLIO

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm

RoHS. Shock / vibration resistant. Magnetic field proof. Many variants

LM10. Micro Laser Displacement Sensor. The LM10 makes laser sensors super easy to use! New circuitry lowers costs

Electric Rotary Actuator - On/Off or programmable control actuator

Inductive Proximity Sensors

Contactless Encoder RI360P0-QR24M0-INCRX2-H1181

Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5

technical data (according to IEC )

Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in

Technical data. General specifications. Indicators/operating means. Electrical specifications Operating voltage U B Power consumption P 0 Interface

mecotron Safety relay ESTOP-2 For emergency stop monitoring

Sensing method Appearance a Connection o method Sensing distance Model NPN output PNP output Through-beam Pre-wired (see note 3) Connector.

OPERATING PRINCIPLES FOR PHOTOELECTRIC SENSORS

How To Read A Pipe From A Sensor

Mounting holes. (threaded M4) Switching state indication (5 yellow LEDs)

Adjustment functions for both span and shift have been incorporated

New XUY roller sensors

How To Use An Od Max Sensor System For Distance Measurement

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

In-Sight Hardware specifications

Plug and Socket Devices CES 63 A Series 8579

Multifunction devices

T-SERIES INDUSTRIAL INCLINOMETER ANALOG INTERFACE

Electronic Pressure Switch EDS 300

Housing diameter Shaft diameter 1. Flange (Mounting of housing) Protection class shaft input (EN 60529) Protection class housing (EN 60529)

ALARM ANNUNCIATOR ME INSTRUCTION MANUAL

TECHNICAL DATASHEET Incremental Encoder RI 58-D / RI 58TD

Universal Voltage Terminal Photoelectric E3JM

Operating instructions Diffuse reflection sensor with background suppression O1D101 O1D / / 2012

Inductive sensor NI10-M18-Y1X-H1141

E2EL Ø 6,5 M8 / Plug M8 M8 / Plug M12 E2EL

TECHNICAL DATASHEET Incremental Encoder RI 58-H

ACS-30-EU-EMDR-10-MOD

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...

Preset Counter signo 721

Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx

Temperature sensor with integrated transmitter for industrial applications, MBT 3560

Multi-function Card. 1 Description. 2 Technical data ESSK General. 1.2 Application example

Linear Luminaire with LED Series EXLUX 6402/2

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

XUSL4E4BB091NS2 XUSL type 4 - Slave2 - For body protection - 4 Beams, Hp = 910 mm

VIBRATION MONITORING OF FANS INSTALLED IN ROAD TUNNELS

Electronic Pressure Switch EDS 3000

Small U-shaped Micro Photoelectric Sensor. Enables space saving and quick installation!

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.

Givare NC-SRS 280 och 880

Operating instructions Optical distance sensor O1D100 O1D / / 2012

SAFETY LIGHT CURTAINS

Original instructions Tina 3A/Aps Adaptor unit

Transcription:

LUT Luminescence scanners Luminescence scanners LUT Luminescence scanners: Seeing what no-one else can Special features: A semi-conductor light source is used in the LUT series no lamp change required. Interchangeable lenses allow scanning distances of 0, 0, 0 and 90 mm. Filters allow the spectral sensitivity to be limited so that the sensor can be adapted to detect certain luminophores. LLUT luminescence scanners can detect luminophores (both natural and those that have been The high switching frequency of 00/s permits fast machine cycle times. Adjustable time delay, analogue output, PNP and NPN switching outputs. deliberately added or attached for product identification purposes) which are invisible to the naked eye. These substances become luminous when the UV light source of the LUT excites the electrons of the luminophores. The visible light produced in this way is used to detect the target Checking packaging processes, controlling wood-working machines and monitoring the application of a material coating just a few examples of applications where luminophores are reliably detected by LUT luminescence scanners. object. The background on which the luminophores are attached has no effect on the reliability of detection. SENSICK CATALOGUE

LUT m Label present or not: the LUT -8 knows the answer (here being used in the pharmaceutical industry). v Luminescence scanners being used to align aerosol cans. b LUT - luminescence scanners used to ensure that brake callipers for vehicles are correctly fed in. n Reliable attachment of labels: The LUT luminescence scanner checking whether the label has been transferred from the gluespreading roller to the bottle. v Once a fluorescent marking has been applied during quality control, tiles can be sorted automatically into quality categories using a luminescence scanner. m LUT -8 luminescence scanner with filter for detecting markings used to control a circular saw. SENSICK CATALOGUE

LUT - Luminescence scanners 0...0 mm Luminescence scanners Dimensional drawing 9 8 LUT -0 LUT -0 LUT -0 UV semi-conductor light source No lamp replacement selectable by using interchangeable lenses M M 0 0.. 9. 8 80 Adjustments possible ON 8 9 M threaded mounting hole,. mm deep Light spot direction Centre of optical axis See dimensional drawing for lens M plug (rotatable) Operating indicator Not used Sensitivity adjustment Output indicator 9 Q Sensitivity 8 C V ON Accessories page Cable receptacles 9 Lenses -pin, M brn blk blu wht L+ Q P M Q N 8 SENSICK CATALOGUE

LUT - Technical Data LUT - 0 0 0 ) / light spot sizes Light spot direction 0 mm/ x mm 0 mm/ x 9 mm 0 mm/ x mm Longitudinal Light source ), light type Wavelength UV light source 80 nm Supply voltage V S...0 V DC ) Ripple ) max. V Current consumption ) 0 ma Switching outputs Output current l A max. Response time ) Switching frequency ) Light-switching PNP: HIGH = V S < V/LOW = 0 V NPN: HIGH = V S / LOW = < V 00 ma 0. ms. khz Plug VDE protection class 8) Circuit protection 9) V A, B, C Enclosure rating IP Ambient temperature T A Operation 0 C...+ C Storage C...+ C Shock load To IEC 8 Weight Approx. 00 g Housing material Die-cast metal ) From front edge of lens ) Average service life 00,000 h at T A = + C ) Limit values ) May not exceed or fall short of V S tolerances ) Without load ) Signal transit time with resistive load ) With light/dark ratio : 8) Reference voltage DC 0 V 9) A = V S connections reverse-polarity B = Outputs Q P and Q N short-circuit C = Interference pulse suppression 00 0 00 0 Order information Type Part no. LUT -0 0 9 LUT -0 0 9 LUT -0 0 98 LUT - is not supplied with additional filter or fibre-optic cable OBJ-LUT -0 0 8 OBJ-LUT -0 0 9 OBJ-LUT -0 0 0 Rel. sensitivity in % 00 0 0 (mm) 0 0 0 0 mm 0 mm 0 mm SENSICK CATALOGUE 9

LUT -8/9 Luminescence scanners 0...90 mm Luminescence scanners UV semi-conductor light source No lamp replacement selectable by using interchangeable lenses Fibre-optic cable connection Analogue output Additional optical filter Dimensional drawing 9 8 M M 0 0. LUT -80 LUT -90 LUT -80 LUT -80 LUT -8 LUT -8 LUT -8 LUT -90 LUT -90 LUT -9 LUT -9 LUT -9 9. 8 80. LUT -890 Adjustments possible Ø Ø. 0. 9 ON Q Off-Delay ms 0 0 0 8 8 9 M threaded mounting hole,. mm deep Light spot direction Centre of optical axis See dimensional drawing for lens M plug (rotatable) Operating indicator Time delay selector switch Sensitivity adjustment Output indicator C V ON Accessories page Cable receptacles 9 Lenses -pin, M brn blk blu wht gra L+ Q P M Q N Q A 0 SENSICK CATALOGUE

LUT -8/9 Technical Data LUT - 80 80 80 890 8 8 8 90 90 90 ) / light spot sizes Light spot direction 0 mm/ x mm 0 mm/ x 9 mm 0 mm/ x mm 90 mm/8 x 0 mm Longitudinal Light source ), light type UV light source Wavelength 8 nm 0 nm Receiver filter OG 0 RG 0 RG Supply voltage V S...0 V DC ) Ripple ) max. V Current consumption ) 0 ma Switching outputs Output current l A max. Response time ) Switching frequency ) Time delay (deactivation delay) Analogue output Q A Light-switching PNP: HIGH = V S < V/LOW = 0 V NPN: HIGH = V S / LOW = < V 00 ma 0. ms. khz ms, ms, 0 ms, 0 ms, adjustable 0...0 ma, 800 Ω Plug VDE protection class 8) Circuit protection 9) V A, B, C Enclosure rating IP Ambient temperature T A Operation 0 C...+ C Storage C...+ C Shock load To IEC 8 Weight Approx. 00 g Housing material Die-cast metal ) From front edge of lens ) Average service life 00,000 h at T A = + C ) Limit values ) May not exceed or fall short of V S tolerances ) Without load ) Signal transit time with resistive load ) With light/dark ratio : 8) Reference voltage DC 0 V 9) A = V S connections reverse-polarity B = Outputs Q P and Q N short-circuit C = Interference pulse suppression 00 0 00 0 0 mm 0 mm 0 mm 90 mm Order information Type Part no. LUT -80 0 8 LUT -80 0 88 LUT -80 0 89 LUT -890 0 08 LUT -90 09 8 LUT -90 09 8 LUT -90 09 8 With additional optical filters Rel. sensitivity in % 00 0 0 (mm) 0 0 0 80 00 LUT -8 0 80 LUT -8 0 8 LUT -8 0 8 LUT -9 09 88 LUT -9 09 89 LUT -9 09 90 SENSICK CATALOGUE

LUT - Luminescence scanners 0...90 mm Luminescence scanners UV semi-conductor light source with high-pressure mercury vapour lamp selectable by using interchangeable lenses Fibre-optic connection Additional optical filter Dimensional drawing 00 "X" A-B M 0 9 0 ø0 88 0 0. 8 "X" A ø8, ø 0 R. 0 0 0 B Adjustments possible LUT -0 LUT -0 LUT -0 LUT -0 LUT -0 0 0 0 0 OUTPUT NOT READY /ALARM SENSITIVITY[E] t on/off [ms]. 0. E max Lens, see dimensional drawing Readiness indicator Status indicator Sensitivity adjustment Digital intensity signal Threaded mounting hole, mm deep C V Accessories page Cable receptacles 9 Fibre-optic cable Lenses Bridge LUT - -pin + PE red blu grn brn wht blk yel L+ M Q L Q B Q A NC NC PE Truth table LUT - Internal jumper o a o b o o a o b o Delivered state Switching type Light-switching Dark-switching Sender lamp off started off started Luminescence yes no yes no Output QB (PNP) LOW HIGH LOW HIGH Readiness indicator (red) on off/flashing*) an off/flashing*) Output QL (PNP) LOW HIGH LOW LOW LOW HIGH Status indicator (green) off on off off on off * Flashing: lamp power still sufficient for operation a b SENSICK CATALOGUE

LUT - Technical Data LUT - 00 0 0 0 0 0 ) / light spot diameter With fibre-optic cable, no lens With fibre-optic cable, with lens With fibre-optic cable, with lens and diaphragm 0 mm/l mm 0 mm/l mm 0 mm/l 8 mm mm/l mm 00 mm/l 0 mm 8 mm/l 0 mm mm/l mm mm/l x mm Light source High-pressure mercury vapour lamp Light type, wavelength UV, nm Average service life 000 h Supply voltage V S 8...0 V DC ) Ripple ) V Current consumption ) 00 ma Switching outputs Q ) L and Q ) B Light-/dark-switching, selectable PNP: HIGH = V S < V/LOW = 0 V Output current l A max. 00 ma Max. switching frequency ) khz At max. sensitivity00 Hz Response time 0. ms At max. sensitivity. ms Analogue output Q A 0... V Plug VDE protection class 8) Circuit protection 9) V A, B, C Enclosure rating IP Ambient temperature Operation 0 C...+ C Storage C...+ C Weight. kg Housing material/surface Die-cast metal ) From front edge of lens ) Limit values ) May not exceed or fall short of V S ) Without load ) Q L = signal output ) Q B = operational readiness ) With light/dark ratio : 8) Reference voltage DC 0 V 9) A = V S connections reverse-polarity B = Outputs Q L, Q B and Q LU short-circuit C = Interference pulse suppression 00 00 0 0 mm 0 mm 0 mm mm 00 mm Order information Type LUT -00 LUT -0 LUT -0 LUT -0 LUT -0 LUT -0 Part no. 00 00 9 00 9 00 9 00 98 00 99 Rel. sensitivity in % 0 0 (mm) 0 0 0 00 00 00 000 Special accessories Colour filter Type Wavelength Part no. OBF-OG 0-0...0nm 00 80 OBF-RG 0-0...0nm 0 OBF-RG 0-0...0nm 0 OBF-RG -...0nm 0 Spare lamp SLA-LUT - 00 SENSICK CATALOGUE