Bio-Stack Applications of an Automated Microplate Stacking Device for HTS and Multi- Instrument Interface



Similar documents
CIM Computer Integrated Manufacturing

Best Robotics Sample Program Quick Start

Fluorescent Array Imaging Reader

Hydras 3 LT Quick Start

Envision Reader. Device Driver User Guide. Agilent Technologies

SMS Alarm Messenger. Setup Software Guide. SMSPro_Setup. Revision [Version 2.2]

Performance Qualification of an Automated Plate Washer Using the Artel MVS

Stereoscopic 3D Digital Theater System. Operator Manual (MI-2100)

Model SETR-50 and SETR-51 Trim Tab Control

Nucleic Acid Purity Assessment using A 260 /A 280 Ratios

ValveLink Mobile Software

OPL BASIC. Dosing System for Professional Laundry machines. Contents

Atlas. Automatic Storage & Retrieval Systems

Expert workflow management cobas p 312 pre-analytical system The new dimension of laboratory automation

DUKANE Intelligent Assembly Solutions

AEI RAIL NETWORK SERVER User Manual

Echo. Compact Immunohematology automation. Echo is designed to bring the benefits of automation to labs of all sizes and volumes.

PRODUCTIVITY THROUGH INNOVATION 600 CONTROL DIRECT DRIVE TECHNICAL/OPERATION MANUAL

Cluster Box Units. (CBU s) 3300 Series CBU Door Sizes. Fully Integrated Parcel Lockers CLUSTER BOX UNITS FRONT LOADING. continued on pages 7-11

Research-Grade Research-Grade. Capture

Multi-talented. Valve and valve terminal series VG

Captus 3000 Thyroid Uptake And Well System

3D Printer Extruder. Application Note. Martez Steverson ECE 480. Design Team 8 3/28/14. Abstract

SE05: Getting Started with Cognex DataMan Bar Code Readers - Hands On Lab Werner Solution Expo April 8 & 9

FREQUENTLY ASKED QUESTIONS (FAQs) 123Scan 2 Scanner Configuration Utility 19 April 2011

Page 1. Description

My Ticket. User Guide

Fixed and Adjustable Spacing Electronic Pipettes

UNIT II Robots Drive Systems and End Effectors Part-A Questions

Elite MicroPrint. CDR / DVDR Inkjet Printing. Hardware Installation and Setup Guide

GUTTER MACHINE CONTROLS STANDARD

Optimizing Performance of the Transcreener ADP Assay for the BioTek Synergy 2 and 4 Multi-Mode Microplate Readers

Manual Software SPECTRO3-MONITORING V5.0

PC control for flexible packaging

Welcome to the fischertechnik Computing World 3 About this Activity Booklet 3. Industrial robots 4

PS6500 Storage Arrays Rack Mount Instructions

INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate Locks

AGRI-ALERT 128 TOUCH AGRI-ALERT 800EZE ALARM SYSTEMS

Wireless Service Advisor (WSA)

SPE-TT. Tutorial Version Bruker BioSpin ; File: Tutorial 11 - SPE-TT; Version: ; By: Dr.

Your Personal Pipetting Robot

Quick Start Guide RRL Radio Telemetry

GANTRY ROBOTIC CELL FOR AUTOMATIC STORAGE AND RETREIVAL SYSTEM

How to read this guide

AlarmNet Direct enables checking status, control, and configuration of devices from a Remote Location.

LEGENDplex Data Analysis Software

Gen5 Getting Started Guide

1. Introduction Fixture exterior view Connecting the Robe Universal Interface Software update of the fixture...

EPSON SCANNING TIPS AND TROUBLESHOOTING GUIDE Epson Perfection 3170 Scanner

Operation and Installation Manual

PRORAE REMOTE HOST CONTROLLER: COMMUNICATION TROUBLESHOOTING GUIDE

PARTNER ACS R4.0 Remote Administration R4.0. Getting Started

Synergy Controller Application Note 4 March 2012, Revision F Tidal Engineering Corporation Synergy Controller Bar Code Reader Applications

How To Run A Factory I/O On A Microsoft Gpu 2.5 (Sdk) On A Computer Or Microsoft Powerbook 2.3 (Powerpoint) On An Android Computer Or Macbook 2 (Powerstation) On

The Assembly Automation Industry

HC4300 Portable Flame/Plasma Cutting Machine Control System User Manual

Meso Scale Discovery. WINDOWS is a registered trademark of Microsoft Corporation

INNOVATION TO MEET YOUR NEEDS

NXP Basestation Site Scanning proposal with AISG modems

DS2X00N-DS4800 SCANNER FAMILY

Original Assembly Guide

ROBOTIC PRINTED CIRCUIT BOARD ASSEMBLY LINE

S3000 Quick-Start. The document describes the schedule of a configuration which is valid for the user software CDS 3.xx or higher.

Bluetooth + USB 16 Servo Controller [RKI-1005 & RKI-1205]

NETWORK ENABLED EQUIPMENT MONITOR

Senses SV series industrial monitor user manual

SCHATZ - TEST Tool testing systems. SCHATZ -certest-w. Dynamic testing of torque tools

Rackmount Intelligent Pressure Scanners

Dash 8Xe / Dash 8X Data Acquisition Recorder

ACU-1000 Manual Addendum Replacement of CPM-2 with CPM-4

GC-xt. The most flexible GC /GC-MS liquid sample injector

WxGoos-1 Climate Monitor Installation Instructions Page 1. Connections. Setting an IP Address

Gripper Kit for the Boe-Bot Robot (#28202)

Lighting Control Systems

Database Management Tool Software User Guide

Installation and Operating Instructions for the FluidX IntelliCode software Rev 1, release date: July 2014

Mobile Satellite Solutions. A WiWorld Partner SATELLITE TV ANTENNA CONTROLLER RFM-1000/1100 TECHNICAL MANUAL STOW SEARCH

cams Management Systems Technology focused on conserving energy Performance. Period.

Table of Contents. Safety Warnings..3. Introduction.. 4. Host-side Remote Desktop Connection.. 5. Setting Date and Time... 7

NGSS Data Consolidator (DC)

PALLETS ROLLER CONVEYOR LOADING CONVEYOR CHAIN TRANSFER TURNTABLE ROLLER STOP

FREQUENTLY ASKED QUESTIONS (FAQs) 123Scan 2 Scanner Configuration Utility

History of Innovation

MAINTENANCE & TROUBLESHOOTING

CalMaster2 Field and Software Tools. The world's first battery- and mains-powered in situ flow verification system

HOSPITALITY RISK FACTORS & BEST PRACTICES - LAUNDRY

2» 10» 18» 26» PD »

Cart Interface Installation & Control Board Manual for M38 XP and RX Carts and Legacy M39 Carts

SECTION WEB-BASED POWER MONITORING COMMUNICATIONS SYSTEM

HP USB Smartcard CCID Keyboard. User Guide

Ovation Operator Workstation for Microsoft Windows Operating System Data Sheet

IR-PRO IR-PRO. Operation Guide. Professional Infrared Code Capture System

Modern Robotics, Inc Core Device Discovery Utility. Modern Robotics Inc, 2015

Cooktop Low-Profile Ventilation Hoods

Alpha 488 S. Twisting in a new dimension

USER MANUAL. Kramer Electronics, Ltd. Models:

CMS Central Monitoring System

DSP500 Series Sensors

LOAD & GO and make flow cytometry simplicity itself. the full spectrum of Flow Cytometry

Thermo Scientific Automated ELISA Workstation Faster, Cleaner,

Transcription:

Bio-Stack Applications of an Automated Microplate Stacking Device for HTS and Multi- Instrument Interface Abstract Today s microplate automation spans the range from multi-channel pipettes to large, robotic HTS systems. One popular type of automation is the microplate stacker that allows the unattended loading and unloading of microplates to automated devices for batch processing. Unfortunately, most stacker devices are integrated with each device at the time of manufacture, limiting their utility to that single device. To overcome this limitation, BioTek has developed the Bio-Stack, a stand-alone microplate stacking device that easily integrates with several different products without factory installation or recalibration. The Bio-Stack interfaces directly with the ELx405 Series microplate washers, the industry standard in 96- and 384-well automated microplate washing technology, as well as the µfill, a continuous, rapid reagent dispenser. Several automated Figure 1. Bio-Stack Microplate Stacker microplate readers are also compatible, including the PowerWave Series of scanning absorbance spectrophotometers and the Synergy HT Series multi-detection readers. This unique stacker can be easily transitioned from one instrument to another in minutes without time-consuming recalibration. The Bio-Stack has been designed around durable and reliable technology, resulting in an extremely small footprint, quiet operation and remarkable speed. It delivers or retrieves a microplate in less than 8 seconds. Each easily removable stack accommodates 30 standard 96- or 384-well microplates. The microplate grippers are spring loaded to prevent dropping plates in the event of an untimely loss of power. During startup, onboard diagnostic routines verify correct positioning of all carriers and motor axes, and during operations, monitors for errors. A PC software interface allows for intuitive programming of reader interface routines, including multiple reading protocols per batch, while the programming of stand-alone devices (e.g., ELx405 washer and µfill dispenser) takes place via the device s keypad. The Bio-Stack s diminutive footprint (7" W x 18" L x 25" H) saves precious bench space and fits in most biosafety cabinets or chemical fume hoods. BioTek Instruments, Inc., P.O. Box 998, Highland Park, Winooski, Vermont 05404-0998 USA COPYRIGHT 2006 TEL: 888-451-5171 FAX: 802-655-7941 Outside the USA: 802-655-4740 E-mail: customercare@biotek.com www.biotek.com

Overview The Bio-Stack is a compact microplate stacker capable of holding up to 30 microplates per plate stack (Figure 1). This easy-to-use device has a small footprint and can be integrated with a number of different BioTek products without factory service or calibration (Figures 2 and 3). The easily removable stacks can be swapped in and out to provide continuous processing of microplates. The Bio-Stack uses a lift mechanism to stack and unstack plates to and from the stack columns and microplate carrier. The carrier moves the plate horizontally from the plate stacks to a gripper-claw, which deposits the microplates onto an instrument carrier for processing and retrieves the plate when processing is complete. The Bio-Stack uses stepper motors to drive all motor axis and cams, resulting in rapid, reliable plate movements from one stack to a microplate instrument and back. Typically a plate can be moved from the stacker to an instrument in less than 8 seconds, with the return trip being just as rapid. Onboard sensors ensure completion of each plate movement at every step of the operation. Figure 2. Bio-Stack Microplate Stacker interfaced with a PowerWave HT Microplate Spectrophotometer Figure 3. Bio-Stack Microplate Stacker interfaced with an ELx405 Microplate Washer The instrument has been designed with reliability in mind. The grippers are spring pre-loaded to remain closed in the event of a power failure, maintaining a grip on the plate despite the lack of power. In addition, the gripper was designed to grab each microplate securely from underneath to further eliminate any chance of dropping or twisting during grip routines. When stacking plates, the plates are addressed from below, providing reliable transport. The use of stepper motors to actuate cams provides not only reliable, but also quiet operation. The precision-ground aluminum base has been designed for heavy use, and all of the linear mechanisms have been designed using proven BioTek automation technology. The Bio-Stack interfaces with the µfill microplate reagent dispenser and ELx405 Series microplate washers directly through the instrument s internal software, with programming taking place via the keypad of the interfaced instrument. (Instruments currently in use can be upgraded for use with the new Bio-Stack.) For microplate reader instrumentation, such as the PowerWave Series or the Synergy HT Series readers that require KC4 data reduction software running on a remote PC and do not have keypad programming, remote PC Bio-Stack controlling software is used to program the Bio-Stack. This software interacts with KC4 to select reading protocols, as well as sample and plate information.

Accessory kits are available that provide all of the required alignment hardware and necessary software for integration of the Bio-Stack to any of the compatible BioTek products. Changing the Bio-Stack from one device to another merely requires the use of the appropriate interface kit; no factory installation is required. Plate Movement Process Plates to be processed are loaded into one of the interchangeable stacks and then the stack is located in the input position of the Bio-Stack. If the instrument is either a Synergy HT Series or a PowerWave Series reader, specific reader protocols from KC4 are associated with each plate by means of the Bio-Stack PC control software. These protocols, which identify reading parameters, plate layout, and data reductions specific to the assay, need to be previously created and saved within the KC4 data reduction software Figure A depicts the vertical position of a plate that is already in a stack (red crosshatch), as well as the vertical position stack (red crosshatch), as well as the vertical position of a new plate on the carrier (green crosshatch). Note that the dogs are currently engaged with the previously stacked plate resting on them and the lifters are in Figure B depicts the position of the lifters as they move upward to meet the plate on the carrier. A stepper motor turning a lead-screw assembly drives the lifters. Figure C depicts the lifters position of the new plate (green cross-hatch) as the lifters have begun raising the plate off the carrier. The dogs are still engaged and the previously stacked plates are still resting on them. Note position of the new plate relative to the previously stacked plate. Figure D depicts the lifters raising the plate past the spring-loaded dogs, which have been opened. The previously stacked plate is lifted from the bottom by the new plate being raised upward. At this point the lifter is now raising both plates. Figure E depicts the position of the two plates after the lifter has raised the new plate above the level of the springloaded dogs. At this point the plate stack is clear of the dogs. Once the lifters have reached the level of the lift sensor, the dogs are allowed to close. Figure F depicts the vertical position of the plates after the lifters have begun lowering. The plate stack, which is now two plates, is again resting on the dogs. The next plate to be stacked (blue cross-hatch) is now on the carrier and the process repeats. Figure 4. Cross Sectional View of Bio-Stack Demonstrating the Mechanics of Plate Stacking Once the batch has been initiated, the carrier moves under the input or source stack (Figures 4A, 4F). Next, the input stack lift mechanism moves upward and lifts the entire stack off the "dogs" that are engaged to support the plates within the stack (Figure 4B). The dogs are then opened and the lift is lowered such that the lowest plate is below the dogs, but the lip of the next plate is not (Figure 4C). The dogs are closed slightly to engage the next plate. When the stack is lowered further, the bottom plate will rest on the carrier, while the plates above will remain stacked on top of the closed dogs. The carrier with the released plate is moved to the plate sensor to verify that a plate is actually present. If a plate is not present, an error message is generated.

With the plate successfully positioned on the carrier and verified as such, the carrier moves horizontally, positioning itself below the claw/gripper assembly on the front of the Bio-Stack (Figure 5). The grippers on the claw are opened against the spring-tension that normally keeps them closed when not powered, and the claw/gripper is lowered to the plate. With the claw lowered, the gripper arms are then closed to their "depowered" position, which grips the plate along both sides of its long axis. At this point the Bio-Stack, using the plate sensor located in the gripper, checks that the plate is present. Figure 5. Gripper-head Assembly with a Plate on the Carrier. The plate carrier, with a microplate, has been extended out the front of the Bio- Stack. The microplate is positioned below the gripper head, which moves downward and grips the plate, allowing the carrier to retract. The gripper head then lowers the microplate to the instrument carrier located below. The claw, with the plate in its gripper, is then raised slightly allowing the carrier to retract. After the carrier is retracted, the claw is then lowered to the instrument carrier position below. The grippers are opened, releasing the plate to the instrument. The claw is then lifted; the gripper sensor ensures that there is no longer a plate present. The instrument is then allowed to perform its task. After the instrument has completed its task and the carrier is returned to the original position, the gripper arms are opened and the claw lowered to retrieve the plate. The gripper arms are closed around the plate and the presence of a plate verified. The claw, with the plate in the gripper arms, is lifted above the level of the carrier. The carrier is then extended, the claw lowers the plate onto the carrier, and the gripper is released. Once the plate has been released and the claw is lifted, the carrier is free to retract underneath the destination stack. The position of the carrier is then verified, and the output stack lift is raised, lifting the plate such that it slightly lifts all of the plates present in the stack. The dogs are retracted slightly and the entire stack of plates is lifted above the dogs (Figure 4D). The dogs are then retracted inward and the lift lowered so the entire stack, with the newest plate located on the bottom, is now resting securely on the dogs (Figure 4E). At this point the Bio-Stack is able to repeat the process with the next assigned microplate. When the batch has been completed, the plates will be in the reverse order from where they started in the input stack. If enabled, the Bio- Stack has the capability to restack the plates by moving them from the output stack back to the input stack, which results in re-establishing the order of the original stack. Software PC Control Software is available for the Bio-Stack when interfacing with the BioTek PowerWave Series scanning absorbance spectrophotometers and the Synergy HT Series multi-detection readers. The Bio-Stack PC control software allows the user to select a specific reader protocol for each plate on the input stack. The software graphically indicates the plate ID and location within the stack (Figure 6). In addition, the user can select the assay protocol name, import file name (if used) or plate barcode (if used) to be displayed in conjunction with the plate number in the stack. As plates are completed by the instrument and returned to the output stack, their location is identified with similar choices (Figure 7). The software enables the user to pause the batch in order to add the additional plates or remove plates that have already been processed.

Plates can be added to an existing batch of plates, to either the top of the stack where it will be processed in order, or to the bottom of the stack where it will be processed next. At any time during the run, the user can identify a specific plate in either the input or output stack and inquire about non-displayed information. If it is a non-processed plate in the input stack, the user can also elect to modify its parameters including the reader protocol (Figure 8). If large numbers of plates with the same protocol are to be run, a continuous mode can be enabled that eliminates the need to identify each plate specifically. The automatic plate-numbering feature allows the user to keep track of plates on a daily basis or keep a running total. When batches have been completed, the Bio-Stack can be configured to restack the completed plates so they are located at the same position vertically in the stack as they were when the batch started. During setup, a configuration routine is provided that allows the user to select serial ports, and vertically align the claw and gripper so the plate is placed smoothly on the instrument carrier. As with all BioTek software, a fully informative context-sensitive help system is available to provide a conceptual overview of the Bio-Stack plate stacker system and to answer any questions that may arise (Figure 9). Figure 6. Defining Plates with Bio-Stack PC Control Software. PC software is used to control the Bio-Stack when it is used with the Synergy HT or PowerWave readers. Several plates (up to 30) can be programmed to run. Note that different reader protocols can be identified on a plate-by-plate basis on the input stack. Figure 7. Completed Plates in the Output Stack. PC Control software for the Bio-Stack tracks completed plates to the Output stack. Note that the reader protocol associated with the completed plate is indicated to the right of the plate in the stack. This user-selectable parameter can also be changed to indicate plate barcode or import file. Figure 8. Modifying Plate Parameters. At any time during a batch, specific plates can be identified and more detailed plate parameters displayed. Nonprocessed plates in the input stack can even have the reader protocol changed. Figure 9. Detailed Help System is Available. If questions arise when using the PC control software, answers are only a mouse click away with the detailed and context-sensitive help system.

Compatible Instruments ELx405 Microplate Washer µfill Reagent Microplate Dispenser PowerWave HT Microplate Spectrophotometer PowerWave XS Microplate Spectrophotometer Synergy HT Multi-Detection Microplate Reader Features 30 microplates per stack Simple to use Small footprint Full regulatory compliance Easy alignment of stacks Stepper motor design provides quiet and reliable operation Onboard diagnostics Durable precision-ground aluminum base Speedy plate delivery (8 seconds) Removable and interchangeable stacks Flexible PC software The gripper incorporates rack and pinion drive for synchronous movements Grippers are preloaded with springs, preventing plate dropping in the event of power loss For more information, please contact BioTek Customer Service at 888-451-5171 or visit our Web site at www.biotek.com. Rev. 02/26/04