Similar documents
Inductive sensor NI10-M18-Y1X-H1141

Contactless Encoder RI360P0-QR24M0-INCRX2-H1181

4 non-safe digital I/O channels 2 IO-Link Master V1.1 slots. Figure 1. Figure 2. Type code. TBPN-L1-FDIO1-2IOL Ident no

Programmable set for Ethernet Modbus/TCP in IP20 TI-BL20-PG-EN-8

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

Technical Data. Dimensions

Technical Data. Dimensions

Set for PROFINET IO in IP20 TI-BL20-EN-PN-4

Technical Data. General specifications Switching element function Rated operating distance s n 4 mm

Compact multiprotocol I/O module for Ethernet 8 digital PNP inputs and 8 digital PNP outputs 2 A TBEN-L1-8DIP-8DOP

Technical Data. General specifications Switching element function Rated operating distance s n 15 mm

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Inductive slot sensor

Set for Profibus DPV1 in IP20 TI-BL20-DPV1-8

Table of Contents, Magnetic Field Sensors. Introduction to Magnetic Field Sensors

Magnetic proximity switches

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

Control- and feedback head for integrated mounting on Robolux valves Type 2036

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

Digital input modules

Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx

Plastic tube flowmeters Series PT/PS

How To Use A Flowmeter

Technical Data. General specifications Switching element function PNP NO/NC Rated operating distance s n 8 mm

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT Spur 2. Spur 1. Zone 1. Zone 0

A good connection. International approvals.

Plug and Socket Devices CES 63 A Series 8579

Position Transducers with Restoring Spring 10, 25, 50, 75, 100 mm TR, TRS Series

3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve

Solenoid Valve Island Type 3965

Safety instructions VEGAPULS PS62/63/66/67/68.GI/RI(*)****** IECEx BVS Ex t IIIC T Da, Da/Db, Db IP 66

Electronic Pressure Switch EDS 300

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

Dimensional drawing. Connection type IME08-1B5NOZT0S IME08-1B5NSZT0S IME08-1B5POZT0S IME08-1B5PSZT0S. 3 x 0.14 mm². brn. L+ Schließer/ Öffner M.

Level Switch LBFS. Technical Data. ATEX data Internal inductivity Li < 10 μh Internal capacity Ci < 43 nf Barrier data. Sensor

2.12. page Products for Explosion hazardous Environment

Laser diffuse reflection light scanner with background suppression. Dimensioned drawing

RoHS. Shock / vibration resistant. Magnetic field proof. Many variants

TECHNICAL DATASHEET Incremental Encoder RI 58-D / RI 58TD

RY2 miniature industrial relays

Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5

Proximity Sensors Inductive Thermoplastic Polyester Housing Types EI, DC, M 12, M 18, M 30

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

Electro-pneumatic control valves

BL compact multiprotocol station for Industrial Ethernet SSI interface BLCEN-1M12MT-1SSI

Housing diameter Shaft diameter 1. Flange (Mounting of housing) Protection class shaft input (EN 60529) Protection class housing (EN 60529)

DSD 70 Dual Channel Hall Effect Speed Sensor for Railway Applications, compliant with EN 50155

Operating Instructions

SENSORS. Fiber Optic Sensors - S70. Advanced fiber optic amplifiers for high speed and low contrast applications

System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter

Isolating Barriers for our sensors A5S1 in Ex-areas Series D461

SAFETY MANUAL SIL Switch Amplifier

SEISMIC VELOCITY TRANSDUCER T1-40

XUSL4E4BB091NS2 XUSL type 4 - Slave2 - For body protection - 4 Beams, Hp = 910 mm

Electric Rotary Actuator - On/Off or programmable control actuator

HSP GmbH Zum Handwerkerhof Wendelstein Tel / Fax: / Web: HSP@hsshsp.de NTG-3000.

Series 8146/5-V37 and Series 8150/5-V37

Safety Manual BT50(T) Safety relay / Expansion relay

Proximity Switches RS (Reed Switch)

Tubular Analog model resolution: 0,5 mm (SLOW mode), 1 mm (FAST mode) Right angle Repeatibility: 0,7 mm Vdc

97300 NAMUR series, 3/2 & 5/2 Indirect solenoid actuated spool valve

New XUY roller sensors

Sense it! Connect it! Bus it! Solve it! EncoderS

Contents. Document information

Givare NC-SRS 280 och 880

Cable Plug acc. to DIN EN , Form A

MINI MCR-SL-R-UI(-SP)

Segment Protector for Cabinet Installation R2-SP-IC* Features. Assembly. Function. Connection. Trunk, Ex na non-arcing. Spur.

Plug and Socket Devices SolConeX 16 A Series 8570

TECHNICAL DATASHEET Incremental Encoder RI 58-H

Threaded Resistance Thermometers Model TR10-D, Miniature Design

Linear Luminaire with LED Series EXLUX 6402/2

Temperature sensor with integrated transmitter for industrial applications, MBT 3560

Flow switches Series AD/VH

3DLevelScanner II TECHNICAL DATA SHEET

Instructions for Safe Use

Adjustment functions for both span and shift have been incorporated

TECHNICAL DATASHEET Incremental Encoder RI 58-O / RI 58-T

Technical data sheet TDS0070

3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve

RM35UA13MW. range V. Main. Product or component type. Relay monitored parameters

Inductive proximity sensors IM 12 series, sensing range 2 / 4 mm DC 3-wire, metal housing

Ordering Information. Cylindrical Proximity Sensor E2E/E2E2

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

Instruction Manual. T3111 T3111L T3111P T3111Ex

Redundancy Module QUINT-DIODE/40

type V46, solenoid or pneumatic operated

Combi switchbox with integrated 3/2 way pilot valve

Compact Sensors - S8 Series. Compact size and high performance for the most challenging detection applications

SENSORS. Miniature Sensors - S3Z. Advanced line of miniature Asian style of photoelectric sensors mm background suppression

Description. Dimensions. Features. precision works better

3/2-way Solenoid Valve, direct-acting, NC or NO

Terminal Boxes Series 8146

4/2-Way Pneumatic Solenoid Valve

Pluggable interface relays CR-P Pcb relays

Series 7500 Torque Sensor

Differential Charge Amplifier

Transcription:

ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Rectangular, height 6mm Plastic, PA12 Magnetic-inductive sensor DC 2-wire, nom. 8.2 VDC Output acc. to DIN EN 60947-5-6 (NA- MUR) Male connector M12 x 1 Wiring Diagram Type code Ident no. 1056801 Pass speed ð 10 m/s Repeatability ï ± 0.1 mm Temperature drift ð 0.1 mm Hysteresis ð 1 mm Ambient temperature -25 +70 C Output function Switching frequency Voltage Non-actuated current consumption Actuated current consumption Approval acc. to 2-wire, NAMUR 1 khz Nom. 8.2 VDC ð 1.2 ma ï 2.1 ma KEMA 02 ATEX 1090X Functional principle Magnetic field sensors are activated by magnetic fields and are especially suited for piston position detection in pneumatic cylinders. Based on the fact that magnetic fields can permeate non-magnetizable metals, it is possible to detect a permanent magnet attached to the piston through the aluminium wall of the cylinder. Construction rectangular, INT Dimensions 32 x 5 x 6 mm Housing material Plastic, PA12 Active area material Plastic, PA12 Tightening torque fixing screw 0.4 Nm Connection Flange connector, M12 x 1 Cable quality 3 mm, Blue, Lif9YYW, PVC, 0.3m Cable cross section 2 x 0.14 mm 2 Vibration resistance 55 Hz (1 mm) Shock resistance 30 g (11 ms) Protection class IP67 MTTF 6198 years acc. to SN 29500 (Ed. 99) 40 C Mounting on the following profiles. Cylindrical design E N K F Switching state LED yellow 1 / 5 Hans Turck GmbH & Co.KG ñ D-45472 Mülheim an der Ruhr ñ Witzlebenstraße 7 ñ Tel. 0208 4952-0 ñ Fax 0208 4952-264 ñ more@turck.com ñ www.turck.com

2 / 5 Hans Turck GmbH & Co.KG ñ D-45472 Mülheim an der Ruhr ñ Witzlebenstraße 7 ñ Tel. 0208 4952-0 ñ Fax 0208 4952-264 ñ more@turck.com ñ www.turck.com

Accessories Type code Ident no. Description IMC-Di-22Ex-PNO/24VDC 7560003 2-channel isolating switching amplifier with M12x1 males, for peripheral use, IP67, zones 2/22, input circuits II(1) Ex ia, PNP transistor output NO IM1-22EX-R 7541231 Isolating switching amplifier, 2-channel; 2 relay outputs; input NAMUR signal; selectable ON/OFF mode for wire-break and short-circuit monitoring; adjustable output mode (NO / NC mode); removable terminal blocks; width 18 mm; universal power supply unit KLZ1-INT 6970410 Accessories for mounting the sensors BIM-INT and BIM-UNT on tie-rod cylinders; Cylinder diameter: 32 40 mm; material: Aluminium; Further mounting accessories for other cylinder diameters on request KLDT-1 6913342 Mounting on K dovetail groove cylinders; clamping width: 10.5 12.4 mm; material: Aluminium; further mounting accessories for other clamping widths on request KLR1 6970600 Mounting on E round cylinders; material: Trogamid; please order retaining straps separately 3 / 5 Hans Turck GmbH & Co.KG ñ D-45472 Mülheim an der Ruhr ñ Witzlebenstraße 7 ñ Tel. 0208 4952-0 ñ Fax 0208 4952-264 ñ more@turck.com ñ www.turck.com

Accessories Type code Ident no. Description INT STOPPER 6900473 Mounting on N T-groove cylinders; replacement without loss of switching point with additional clamp INT stopper; T- groove dimensions: 5 5.6 mm 4 / 5 Hans Turck GmbH & Co.KG ñ D-45472 Mülheim an der Ruhr ñ Witzlebenstraße 7 ñ Tel. 0208 4952-0 ñ Fax 0208 4952-264 ñ more@turck.com ñ www.turck.com

Operating manual Intended use This device fulfills the directive 94/9/EC and is suited for use in explosion hazardous areas according to EN 60079-0:2012 + A11 and EN 60079-11:2012. Further it is suited for use in safety-related systems, including SIL2 as per IEC 61508. In order to ensure correct operation to the intended purpose it is required to observe the national regulations and directives. For use in explosion hazardous areas conform to classification II 1 G and II 1 D (Group II, Category 1 G, electrical equipment for gaseous atmospheres and category 1 D, electrical equipment for dust atmospheres). Marking (see device or technical data sheet) É II 1 G and Ex ia IIC T6 Ga and É II 1 D Ex ia IIIC T95 C Da acc. to EN 60079-0, -11 Local admissible ambient temperature ATEX category II 2 G electrical equipment -40 +70 C, category II 1 D -25 +70 C. The corresponding temperature classes are provided in the ATEX type-examination certificate. Installation / Commissioning These devices may only be installed, connected and operated by trained and qualified staff. Qualified staff must have knowledge of protection classes, directives and regulations concerning electrical equipment designed for use in explosion hazardous areas. Please verify that the classification and the marking on the device comply with the actual application conditions. This device is only suited for connection to approved Exi circuits compliant to EN60079-0 and -11. Please observe the maximum admissible electrical values. After connection to other circuits the sensor may no longer be used in Exi installations. When interconnected to (associated) electrical equipment, it is required to perform the "Proof of intrinsic safety" (EN60079-14). When employed in safety systems to IEC 51408 it is required to assess the failure probability (PFD) of the complete circuitry. Installation and mounting instructions Avoid static charging of cables and plastic devices. Please only clean the device with a damp cloth. Do not install the device in a dust flow and avoid build-up of dust deposits on the device. If the devices and the cable could be subject to mechanical damage, they must be protected accordingly. They must also be shielded against strong electro-magnetic fields. The pin configuration and the electrical specifications can be taken from the device marking or the technical data sheet. In order to avoid contamination of the device, please remove possible blanking plugs of the cable glands or connectors only shortly before inserting the cable or opening the cable socket. service / maintenance Repairs are not possible. The approval expires if the device is repaired or modified by a person other than the manufacturer. The most important data from the approval are listed. 5 / 5 Hans Turck GmbH & Co.KG ñ D-45472 Mülheim an der Ruhr ñ Witzlebenstraße 7 ñ Tel. 0208 4952-0 ñ Fax 0208 4952-264 ñ more@turck.com ñ www.turck.com