Aalborg Universitet. CLIMA 2016 - proceedings of the 12th REHVA World Congress Heiselberg, Per Kvols. Publication date: 2016

From this document you will learn the answers to the following questions:

What is the central ventilation system used in?

What part of the building should water condensation be prevented?

What is the name of the building where the central ventilation system is used?

Similar documents
Aalborg Universitet. Energy upgrading measures improve also indoor climate Foldbjerg, Peter; Knudsen, Henrik Nellemose. Published in: REHVA Journal

Published in: The 7th International Energy Agency Annex 44 Forum : October The University of Hong Kong

Aalborg Universitet. CLIMA proceedings of the 12th REHVA World Congress Heiselberg, Per Kvols. Publication date: 2016

CHAPTER 3. BUILDING THERMAL LOAD ESTIMATION

Energy savings in the residential area are essential in

Answers to Your Questions from the Webinar

High Performance School Buildings Resource and Strategy Guide

Energy Efficient HVAC-system and Building Design

HVAC Efficiency Definitions

Climate and Energy Responsive Housing in Continental Climates. The Suitability of Passive Houses for Iran's Dry and Cold Climate. Farshad Nasrollahi

Indoor Environmental Quality of the first European ModelHome 2020 Foldbjerg, Peter; Sørensen, Gitte Gylling; Feifer, Lone; Hansen, Ellen Kathrine

DESIGN OF NATURAL VENTILATION WITH CFD CHAPTER SEVEN. Qingyan Chen. difficult to understand and model, even for simple

Benchmarking Energy Performance of Aquatic Centres in Australia

CFD AND MULTI-ZONE MODELLING OF FOG FORMATION RISK IN A NATURALLY VENTILATED INDUSTRIAL BUILDING

Yijun Gao, Wei Wu, Zongwei Han, Xianting Li *

THE NATIONAL BUILDING REGULATIONS PART XA: ENERGY EFFICIENCY. Presentation by Peter Henshall-Howard: HEAD: BUILDING DEVELOPMENT MANAGEMENT.

Pool Dehumidification Basics

Performance of low pressure mechanical ventilation concept with diffuse ceiling inlet for renovation of school classrooms

Energy Efficiency HOSPITALITY.

3-D Modeller Rendered Visualisations

Solar Homes Catch the Sun. Are you planning a new house? Discover how you can apply solar architecture principles to:

EFFECTS OF INDOOR RELATIVE HUMIDITY ON REFRIGERATED DISPLAY CASE PERFORMANCE

Adaptive strategies for office spaces in the UK climate

FIRST RADIANT COOLED COMMERCIAL BUILDING IN INDIA CRITICAL ANALYSIS OF ENERGY, COMFORT AND COST

Diego Ibarra Christoph Reinhart Harvard Graduate School of Design

HEATING, VENTILATION & AIR CONDITIONING

saving energy in comfort Factsheet Recair Enthalpy

Carnegie Mellon University School of Architecture, Department of Mechanical Engineering Center for Building Performance and Diagnostics

THE COMFORT HOUSES. - The Experienced and Measured Indoor Environment

Green Building Handbook for South Africa Chapter: Heating, Ventilation and Cooling Luke Osburn CSIR Built Environment

SWIMMING POOL AIR-HANDLING UNITS KU-DB Series

Software Development for Cooling Load Estimation by CLTD Method

Heat Recovery from Data Centres Conference Designing Energy Efficient Data Centres

Mechanical and Natural Ventilation

Opening the Bonnet. Prof Darren Woolf WYSINWYG 1

Parametric Analysis of School Classroom Typologies' Energy Performance

Energy Management in Wuppertal

Exemplary Retrofitting of an Old School in Stuttgart - EROS -

Heat Recovery Dehumidification (HRD) system. Designed for municipal swimming pools

Tectonic Thinking Beim, Anne; Bech-Danielsen, Claus; Bundgaard, Charlotte; Madsen, Ulrik Stylsvig

SIMULATION OF RADIANT COOLING PERFORMANCE WITH

Federation of European Heating, Ventilation and Air-conditioning Associations

AQUACIAT2 HYBRID THE COMPACT DUAL-ENERGY SOLUTION HEAT PUMP & GAS BOILER. Cooling and heating capacities of 45 to 80 kw AVAILABLE 2 ND QUARTER OF 2014

SBi 2013:14. Study of a Two-Pipe Chilled Beam System for both Cooling and Heating of Office Buildings

Improving thermal insulation of concrete sandwich panel buildings

Executive Order amending the Executive Order on the Publication of the Danish Building Regulations 2010 (BR10) 1)

PV THERMAL SYSTEMS - CAPTURING THE UNTAPPED ENERGY

A Roof Integrated Solar Heating System Without Storage

Study on Performance Evaluation of a Split Air Conditioning System Under the Actual Conditions

HEATING OF DOMESTIC OUTDOOR SWIMMING POOLS

The District Energy Manager and Classroom Heating

Case study on residential building renovation and its impact on the energy use and thermal comfort

How To Make Your House Breathe

MODELLING AND OPTIMIZATION OF DIRECT EXPANSION AIR CONDITIONING SYSTEM FOR COMMERCIAL BUILDING ENERGY SAVING

Climotion ensures a better climate. Better comfort and lower costs in all buildings. Bosch Energy and Building Solutions

Passive house rehabilitation of post war residential building in Zug, Switzerland

Evaporative Cooling for Residential and Light-Commercial

Infrastructure & Cities Sector

AIR CONDITIONING EFFICIENCY F8 Energy eco-efficiency opportunities in Queensland Foundries

Theoretical Study on Separate Sensible and Latent Cooling Air-Conditioning System

06150 PORVOO, FINLAND Pelican eco ED(D), Pelican eco EDE(D), Pelican eco EDW(D), Pelican eco EDX(D)

Simulation of hygroscopic materials in the HVAC system of an office building

Glossary of HVAC Terms

PERFORMANCE EVALUATION OF WATER-FLOW WINDOW GLAZING

COMPARISON OF THE THERMAL ENVIRONMENT IN ROOMS WITH CHILLED BEAM AND RADIANT PANEL SYSTEMS

VENTILATIVE COOLING EBC ANNEX 62 PER HEISELBERG DEPARTMENT OF CIVIL ENGINEERING

HVAC For Schools How to purchase an HVAC system that meets your school s unique requirements and stays within your budget

EnergyPro Building Energy Analysis. Assisted Living Building

Evaporative Cooling. Terminology. Date: February 28, Concepts

Thank you for the opportunity to comment on the Canine Health Board Standards for Commercial Kennels.

SELECTIVE GLAZING FOR SUN CONTROL

Solar Energy Utilisation in Buildings

Residential HVAC System Sizing

Energy Efficiency. Energy Efficient Home Cooling:

Venice Library Humidity Study. for Williams Building Diagnostics, LLC th Street West Bradenton, FL Report April 13, 2015

Residential HVAC Load Sizing Training October 14, David Kaiser Green Code Plan Reviewer

Market Potential Study for Water Heater Demand Management

Eco Pelmet Modelling and Assessment. CFD Based Study. Report Number R1D1. 13 January 2015

Optimum Solar Orientation: Miami, Florida

DISTRIBUTED GENERATION AND ENERGY EFFICIENCY FOR ACHIEVING ENERGY SELF-SUSTAINING INDUSTRIAL AREAS

EUROPEAN COMMISSION. Energy Audits - Cyprus

Simplified Procedure For Estimating Air- Conditioning Cooling Load In Ghana

Energy Saving Tips. Adjust set point temperature up a few degrees... Window contact. Occupancy sensor. A Programmable Thermostat

FACTORS AFFECTING ENERGY CONSUMPTION OF BUILDINGS

Creating Efficient HVAC Systems

BYG DTU. Thermal properties of window frame Type 1 Sheet: 1. Type: Side, top and bottom profile. Source file: Format: dwg/dxf bmp

Heat Pumps for Swimming Pools

Dispelling the Solar Myth - Evacuated Tube versus Flat Plate Panels. W illiam Comerford Sales Manager Ireland Kingspan Renewables Ltd.

Frost Damage of Roof Tiles in Relatively Warm Areas in Japan

Analysis of HVAC Control Strategies

Delivering on innovation and market uptake. Best-in-cases of nzeb. Ramon Pascual Bucharest May 8th, 2015

Thermal destratification in buildings: The missing piece to the HVAC puzzle

Best Practices for Crawl Space Insulation

How To Get A Passive House

Zoned Air Conditioners - A Real Value?

A guide to using variable-speed drives and motors in swimming pool halls

SIMULATION - ASSISTED AUDIT OF AN AIR CONDITIONED OFFICE BUILDING

Because here you can see a simple an elementary direct evaporative cooling system this is called as a single stage system you can see from the

Verizon SMARTS Data Center Design Phase 1 Conceptual Study Report Ms. Leah Zabarenko Verizon Business 2606A Carsins Run Road Aberdeen, MD 21001

HVAC Costs. Reducing Building. Building owners are caught between two powerful forces the need to lower energy costs. By Stephen J.

Transcription:

Aalborg Universitet CLIMA 2016 - proceedings of the 12th REHVA World Congress Heiselberg, Per Kvols Publication date: 2016 Document Version Publisher's PDF, also known as Version of record Link to publication from Aalborg University Citation for published version (APA): Heiselberg, P. K. (Ed.) (2016). CLIMA 2016 - proceedings of the 12th REHVA World Congress: volume 5. Aalborg: Aalborg University, Department of Civil Engineering. General rights Copyright and moral rights for the publications made accessible in the public portal are retained by the authors and/or other copyright owners and it is a condition of accessing publications that users recognise and abide by the legal requirements associated with these rights.? Users may download and print one copy of any publication from the public portal for the purpose of private study or research.? You may not further distribute the material or use it for any profit-making activity or commercial gain? You may freely distribute the URL identifying the publication in the public portal? Take down policy If you believe that this document breaches copyright please contact us at vbn@aub.aau.dk providing details, and we will remove access to the work immediately and investigate your claim. Downloaded from vbn.aau.dk on: August 20, 2016

Installation of Decentralized Ventilation System for Ventilation of an Indoor Swimming Pool Katarzyna Ratajczak #1, Edward Szczechowiak #2 # Poznan University of Technology Faculty Environmental Engineering Berdychowo 4, 60-965 Poznan, Poland 1 katarzyna.m.ratajczak @put.poznan.pl 2 edward.szczechowiak@put.poznan.pl Abstract In swimming pool facilities ventilation systems are, in addition to water preparation systems, the most vital elements without which the pool cannot operate. Nowadays central ventilation systems, in which one unit prepares the air of equal parameters for the entire pool hall, are used. This article proposes to move away from this approach in favor of a decentralized system. The main principles of the decentralized ventilation system that show its advantages over a centralized system will be presented. Among the biggest advantages that should be mentioned are improving air quality in the occupied zone and ensuring proper parameters for each location in a pool hall. The article presents the results of a simulation in which the primary energy consumption of heating ventilation air in a typical design of a swimming pool facility has been compared with a decentralized system with a traditional air handling unit and a central system. The results show that decentralized ventilation with properly sized air handling unit provides substantial energy savings, up to 50%, in heating supply air in a pool hall. Key words- decentralized ventilation; swimming pool; air handling unit 1. Introduction Swimming pool halls should be properly maintained with strict conditions to provide thermal comfort for users of these facilities, as well as proper air quality. Air parameters in a pool hall should be appropriately selected so as to: provide thermal comfort for users who are undressed temperature in the occupied zone should be higher than water temperature provide thermal comfort for the audience - if it is designed not to intensify the evaporation from the water surface - air temperature should not be higher than 2 C more than water temperature prevent moisture condensation on building envelope - relative humidity of air should be in the range between 50 to 60% An important issue here is the correct choice of parameters for the air supplied into the pool hall to ensure removal of moisture gains, harmful compounds related to the occurrence of water disinfection by-products and heat losses.

Traditionally designed ventilation systems are based on a pool ventilation unit, which prepares the air for the entire pool hall, providing the same parameters in the whole volume of the pool hall. This leads to significant power consumption by the unit. The central system is also not able to provide the appropriate parameters for each zone of the pool hall. It is recommended to use decentralized ventilation system instead. Here, pool ventilation unit prepares the air only for pool basin area. This saves energy as the air handling unit maintains the required air parameters only for the occupied zone. Thus, swimmers can enjoy thermal comfort. However, it is important to provide protection of building envelope from moisture condensation and implement systems that cover transmission heat losses of a pool hall. [1] 2. Analyzed Swimming Pool Facilities Swimming pool hall can be divided into several zones with different functions [2]: pool basin zone (occupied zone) thermal comfort should be ensured, air and water parameters need to be adjusted to the purpose of the pool, thermal balance of this zone does not depend on external air temperature building envelope zone thermal balance depends on temperature of external air, air parameters need to prevent water condensation on cold surfaces audience zone - appropriate air parameters providing thermal comfort of dressed audience should be ensured, absence of such a zone causes discomfort in the audience zone due to high temperature and relative humidity; the design should offer the possibility to turn on and off the heating system if there is some competition planned Dividing pool hall into zones ensures proper air parameters in each of the zones. Consequently, energy is saved because the systems are activated only when it is necessary. The division into zones is an indicator for the supply air parameter selection. It should be noted that the separation of pool basin zone and installation of a separate ventilation system, applicable to its use, improves air quality. Outdoor air is supplied directly to the occupied zone. Additionally, air is removed at the bottom of the pool hall, which allows to eliminate disinfection by-products in the place of their origin. The by-products include chloramines and trihalomethanes. Due to the fact that they are heavier than air and are accumulated above the water surface, they are inhaled by swimmers and have harmful effect on them. [2,3,4] A decentralized system, shown on the drawing below (Fig.1), consists of three or four separate ventilation units. Air handling unit 1 operates in pool basin area and is the most important unit in the entire system, it must operate all year round regardless of the weather and the outside air temperature Air handling unit 2 operates in roof area - dries the air and reduces roof heat losses, operates periodically Air handling unit 3 operates in windows area, operates periodically

Air handling unit 4 for the audience, operates when needed a) b) Fig.1. Air distribution system in a swimming pool hall a) central b) decentralized [2] Two types of swimming pool facilities have been analyzed. Pool hall A is a traditional swimming pool, 25 m long, while pool hall B is a small hotel pool located on the middle floor of a high building. The characteristic parameters of these facilities are summarized in Table 1.

Table 1. Parameters of analyzed swimming pool facilities Parameter Structure A Structure B Water surface [m 2 ] 325 109 External walls surface [m 2 ] 1005 284 Windows surface [m 2 ] 657 84 Average heat transfer coefficient [W/(m 2. K)] 0,89 0,60 Volume of the pool hall [m 2 ] 3900 680 Two types of ventilation systems for the pool hall have been chosen - central and decentralized. The analyzed variants are presented in Table 2. 3. Method Table 2. Variants for the calculations Variant Pool hall Ventilation system 1 A Central 2 B Central 3 A Decentralized 4 B Decentralized The calculations of the amount of energy required to heat up ventilation air have been performed for two selected pool halls (A and B). The pool hall air is prepared by the air handling unit equipped with a cross heat exchanger and internal recirculation, shown in Fig.2. Fig.2. Air handling unit with heat exchanger and internal recirculation The calculation results are determined by the climate data, namely the location of the building as well as parameters of indoor air. The calculation assumptions are presented in Table 3.

Temperature, o C Table 3. Input data for the calculation Supply air stream at daytime m su 40 kg/(h.m2) Supply air stream at nighttime m su,n 32kg/(h.m2) Heat recovery efficiency ƞ 60% Air parameters in swimming pool hall t a a x a 30 o C 60% 16g/kg Climate parameters shown in Fig. 3 and 4 [5] Supply air temperature shown in Fig. 3 and 4 [6] Temperature, o C 40 35 30 25 20 15 10 5 0-5 -10-15 -20 Pool hall A 0 1000 2000 3000 4000 5000 6000 7000 8000 External air temperature Structure A - central ventilation system Structure A - decentralized ventilation system 40 35 30 25 20 15 10 5 0-5 -10-15 Fig.3.External and supply air temperature over a year period for pool hall A Pool hall B -20 0 1000 2000 3000 4000 5000 6000 7000 8000 External air temperature Structure B - central ventilation system Structure B - decentralized ventilation system Fig.4. External and supply air temperature over a year period for pool hall B

[kwh/(m 2. year)] For the calculation of heating power of the air heater in the air handling unit the following equations (1)-(4) have been used. They are related to equipment and circumstances/processes that take/have place in the unit. Q ha =m su. c ps. (t su -t M )/3600 [kw] (1) Supply air temperature (t su ) calculations included thermal balance and moisture balance of pool hall and pool basin area. The graphs above (Fig. 3 and Fig.4) present the results of these calculations. The red color is used to demonstrate the case of central ventilation system and the green is used for decentralized system. The parameters of air before air heater (t M,x M ) are the result of the participation of fresh air which must be delivered to the pool hall in order to ensure proper moisture content, to pick up moisture gains arising as a result of evaporation of water (2). ε e =(x M -x a )/(x E -x a ) (2) In order to determine the temperature before the air heater (4), temperature after the heat exchanger should be defined (3). 4. Results t ex =t e +ƞ. (t a -t e ) [ o C] (3) t M =ε e. t ex +(1- ε e ). t a [ o C] (4) The graphs below (Fig.5 and Fig.6) show the results of the calculations of the air heater power for selected types of swimming pool facilities (pool hall A and B), located in Poznan, with central and decentralized ventilation systems. The air heater power is 1056 and 569 kwh/(m 2. year) respectively. Energy needed to heat up supply air 1 200 1 000 800 600 400 200 - Structure A Structure B Central ventilation system Decentralized ventilation system Fig.5. Energy needed to heat up supply air for different structures and ventilation systems

Energy saved owing to the use of decentralized ventilation system in pool hall A, as shown on the bar graph below (Fig.6), is significant - 53%. As for pool hall B, it is only 16%. Due to the fact that pool hall B has a small pool hall volume, heat losses in this case are small. It is a similar situation to the calculation of pool basin area for decentralized ventilation. Energy saved through the use of decentralized ventilation system 60 50 40 [%] 30 20 10 0 Structure A Structure B Fig.6. Energy saved through the use of decentralized ventilation system 5. Conclusions Parameters of supply air should be adjusted depending on the ventilation system. The use of decentralized ventilation system means that each zone of the pool hall has appropriate parameters required for operational reasons. In addition, the use of decentralized ventilation system reduces primary energy consumption because some of the systems can only operate at low outdoor temperatures and not all year round, as it is the case with central ventilation system in which air handling unit ensures equal performance across the pool hall. Designing appropriate air separation system, as it is in the case of decentralized ventilation system, will further improve air quality by removing disinfection byproducts at their source. Analyses indicate that by using the decentralized ventilation system, energy savings of up to 50% can be achieved, depending on the type of facility, its architecture and construction and geographic location. The larger the indoor pool hall volume, the greater the energy savings. However, in the case of decentralized ventilation system, additional expenses of energy for heating and other potential securing of glazed building envelope have to be incurred. Additionally, installation of a heat pump in the air handling unit may even lead to greater energy savings for heating ventilation air.. This article focuses on showing differences in primary energy consumption by the air handling unit for an indoor swimming pool. Attention has been paid to other problems

occurring in the halls of indoor swimming pools as: removing moisture gains, eliminate any harmful contamination or the need for use of additional equipment for decentralized ventilation system. Problems occurring swimming pools are so wide that it was decided to examine only some of them. The future work will describe in more detail the other issues that are as important as energy consumption of air handling unit. Acknowledgments The first author of this paper is a recipient of the National Swimming Pool Foundation Fellowship 2015 received from National Swimming Pool Foundation with its registered office in Colorado Springs, Colorado, USA. References [1] K. Ratajczak, E. Szczechowiak. Rozdział powietrza w krytych basenach pływackich dla układu centralnego i zdecentralizowanego. Air, Heat & Energy in Buildings 2014. Conference Procedeengs, Wroclaw University of Technology, Wroclaw 2014. (in Polish) [2] K. Ratajczak, E. Szczechowiak. Energy Efficient HVAC System in the Indoor Swimming Pool Facilities. CLIMA 2013. Proceedings of 11th REHVA World Congress & 8th International Conference on IAQVEC Energy Efficient, Smart and Healthy Building, 16-19.06.2013 Prague [3] Weng S.-C., Weaver W.A., Zareafifi M., Blatchley T.N., Cramer J.S., Chen J., Blatchley III E.R., Dynamics of gas-phase trichloramine (NCl 3) in chlorinated, indoor swimming pool facilities, Indoor Air, 2011; 21: 391 399. [4] Weaver W.A., Li J., Wen Y., Johnston J., Blatchley M.R. and Blatchley E.R. III, Volatile disinfection byproduct analysis from chlorinated indoor swimming pools, Water Research 2009, 43, 3308 3318. [5] www.mir.gov.pl, Typical summer weather and statistical climate data for the Polish territory for the calculation of building energy [6] K. Ratajczak, E. Szczechowiak. Parametry powietrza w systemach wentylacji centralnej oraz strefowej hali basenowej i ich wpływ na zużycie ciepła do podgrzania powietrza zewnętrznego. Ciepłownictwo, Ogrzewnictwo, Wentylacja 9/2015. (in Polish)