FAA077A2EMEI IIssued 2006-08-15. EntreMatic Swing Door Operator EMSW USER S MANUAL



Similar documents
EntreMatic EMSW Installation manual

ABLOY DOOR AUTOMATICS Easy access for all types of swing doors


ABLOY EXIT. Functional and technical descriptions Single and double leaf doors. An ASSA ABLOY Group brand

Page 1. Description

ABLOY EL420, EL520 Europrofile motor locks

Security. Alarm central unit. Ref.-No. KNX Alarm central unit EAM 4000

Model 2300DR Installation Guide

Instructions for Use

Instructions for Use

OWNER S OPERATION GUIDE English

Automatic Swinging Door Systems

DUOTOUR WITH SLIDING DOORS OPERATING MANUAL

ENGLISH INSTRUCTION & INSTALLATION MANUAL DUCTLESS MINI SPLIT AIR CONDITIONING SYSTEMS

6000 SERIES Low Energy Power Operator

V1504 Vertical Platform Lift OWNER S MANUAL

OWNER S MANUAL. Permolock C3. Docking system for Power wheelchair in vehicle

Traditional Sonar and DSI Sonar Installation

V1504 Vertical Platform Lift OWNER S MANUAL

EC DECLARATION OF CONFORMITY FOR MACHINES

Installation Instructions

KEYPAD LOCK USERS MANUAL

AD425S Automatic door operator

Instructions for Use

ELECTRIC POSITION for electric heat, then confirm with Fan Test below.

IR Repeater. Operation Manual P8620

HERZ-Thermal Actuators

OWNER'S MANUAL R-410A Duct Free Split System Air Conditioner and Heat Pump

Wireless Alarm System. Window/Door Sensor. User s Manual. Choice ALERT. Control all Sensors & accessories from one location

Wireless Alarm System. Silent Alert. User s Manual. Choice ALERT. Control all Sensors & accessories from one location

RADAR

3M Wrist Strap and Footwear Tester 740. User s Guide

Wireless Home Security System Product Manual (Model #80355)

Accessibility Design Advice

POWER LOCK KIT GENERAL INSTALLATION -J04427 REV Kit Number. Models. Additional Parts Required. Kit Contents

SE-100-1, SE-200-1, SE-500-1, and SE AIR CHAMP PRODUCTS. User Manual SE BRAKE MODELS: (i) MTY (81)

ABLOY EL460, EL461, EL560, EL561 Europrofile handle controlled locks

SECURITY SYSTEM SMART SIREN KIT

Electronically Controlled Air Suspension (ECAS) for Trucks

its ELECTRIC POSITION for electric heat, or set the units fan control appropriately to ELECTRIC or another appropriate setting.

Wireless Alarm System. Panic Button. User s Manual. Choice ALERT. Control all sensors, accessories and remote transmitters from one location

POWER GEAR SLIDE OUT MANUAL

Quality Operators for Garage Doors and Entrance Gates. Garage door operator LIFTRONIC for up-and-over doors and sectional doors

Combination Unit 5'6" Windows a i o P t

WALL MOUNTED SPLIT TYPE AIR CONDITIONER

Drayton Digistat +2RF/+3RF

INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate Locks

MOTION SENSOR PIR LIGHT SWITCH INSTALLATION & OPERATING. Cat No. ZV810 INSTRUCTIONS

SELECTION, APPLICATION AND MAINTENANCE

Manual for GlobePharma Mini-Press II Rotary Tablet Press

Keys Master, submaster and valet key Key number Door locks Power door locking switches

DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS

Telis 4 Soliris RTS Operating and installation guide Ref A

AN500T, AN1000, AN1000T, AN1500, AN1500T AN2000, AN2000T

HP ProDisplay P19A LED Backlit Monitor. User Guide

PowerFlex 700H and 700S AC Drives Frame 11 Main Fan Capacitor Replacement Kit

Floodlight Range Installation Guide

TABLE OF CONTENTS. I. TROUBLESHOOTING Section 1.01: Common Problems/Solutions... 2

EVC40 EMERGENCY VOICE COMMUNICATION SYSTEM

90 Degree PIR Wireless Security Sensor. Installation Instructions 5420/90F

Button 1 Button 2. Button 3 Button 4. Programmed Remote Transmitter. Button Function Condition

Master Time Clock MTC-200 MTC-400 MTC-600. Users Manual

AUTOMATIC SWINGING DOOR

Total Protection Alarm System

MAC FAUCETS. Owner s Manual. Models: FA444

Car Alarm Series 2 B 2 Buttons

SECURITY LIGHT. motion-activated. Assembly & operating instructions Solar Motion-Activated Security Light - 80 LED Lights

Secure Keypads for access control

INTRODUCTION. The data provided is for The Standard Products and any variation will be dealt with at the end of this manual.

Portable Evaporative Air Cooler. OWNER S MANUAL Read and save these instructions before use. Model: CL30XC

Programmable Room Thermostat 7 Day (5-2 Day) Models: / Power Supply: Battery / Mains

Hygro-Thermometer + InfraRed Thermometer Model RH101

BUSINESS. Elektronisches Türschloss. Installation and User Manual. Ingeniously safe. Ingeniously simple.

Combination Unit (shown from interior) WARNING

STEREO PREAMPLIFIER INSTRUCTIONS FOR USE

CONTENTS. 1. CE DECLARATION OF CONFORMITY FOR MACHINES pag DESCRIPTION pag TECHNICAL SPECIFICATIONS pag INSTALLATION pag.

Installation instruction do88 Intercooler for Volvo S40 / V50 / C30

Operating instructions Diffuse reflection sensor. OJ50xx / / 2004

Accessory Manual Ventilation Section Model Comfort Circle

DYNA RIDER FOOTBOARD KIT

B/S/H/ Error codes and service programmes PH

Central Air Conditioner

Operating instructions IV / 2007

R02GA. July 31, Dear Blue Bird Owner:

PROFESSIONAL HOME ALARM SYSTEM. Important! Please read these instructions carefully.

MAKING MODERN LIVING POSSIBLE. AK-SC255 On-Site Installation Guide DANFOSS ELECTRONIC CONTROLS & SENSORS

LOS 2500 SUPER CEILING SENSOR. Installation Manual

Portable Air Conditioner

SmartCard On-Board Reader (# 8105) SmartCard Desktop Reader (# 8108) SmartCards, Pack of 10 (# 8112) Starter Interrupter Kit (# 8116)

Wireless Home Security Alarm System AM 500

Operating Precautions: User configuration options:

E4000 SAFETY RELAY BOX

VK-250 WARRANTY REGISTRATION FORM

DIGITAL WARMING CABINETS

AUTOMATIC SLIDING DOOR

SCHWINTEK IN-WALL SLIDEOUT TROUBLESHOOTING AND COMPONENT REPLACEMENT

Troubleshooting: Door Jamming and Door Handing 6. Troubleshooting: Keypad 11. Troubleshooting: Battery 12. Battery FAQ 13

Transcription:

FAA077A2EMEI IIssued 2006-08-15 EntreMatic Swing Door Operator EMSW USER S MANUAL

All rights in and to this material are the sole property of ASSA ABLOY Entrance Systems AB. Copying, scanning, alterations or modifications are expressly forbidden without the prior written consent of applicable company within ASSA ABLOY Entrance Systems AB. 2 IIssued 2006-08-15 FAA077A2EMEI

Table of content: 1. Important information.............................. 4 2. Service......................................... 5 3. Locks.......................................... 6 3.1 Doors........................................................6 3.2 Unlocking.....................................................6 3.3 Door stop.....................................................6 4. Operation...................................... 7 4.1 Programme selector PS-2 (key)......................................7 4.2 Programme selector PS-3A........................................7 5. Safety......................................... 8 5.1 Safety functions integrated in the operator..............................8 5.2 Safety functions with sensors........................................9 6. Troubleshooting................................. 10 7. Replacement of fuses.............................. 11 7.1 Removing the cover.............................................11 7.2 Replacement of fuses............................................11 8. Accessories.................................... 12 FAA077A2EMEI Issue 2006-08-15 3

Important information 1.0 Important information Important notice! To avoid bodily injury, material damage and malfunction of the product, the instructions contained in this manual must be strictly observed. Note! Instructions, design, specifications and illustrations which are contained in this manual are not binding. Rights reserved for changes without previous notice. Environment This operator may be equipped with batteries containing materials which are hazardous to the environment. Remove the batteries from the operator before it is scrapped. The batteries must be disposed of safely. 4 Issued 2006-08-15 FAA077A2EMEI

Service 2.0 Service When your operator needs to be serviced, contact the nearest authorized EntreMatic service centre. Place for telephone number, stamp, sticker or the like. FAA077A2EMEI Issued 2006-08-15 5

Locks 3.0 Locks 3.1 Doors 3.2 Unlocking Normally the doors and mechanical locks are manufactured by other suppliers. Unlock all the mechanical locks before switching on the operator. Note that more than one lock may be fitted. AAF298EMA 3.3 Door stop A door stop is always recommended in open position to avoid damages on the door leaf. 6 Issued 2006-08-15 FAA077A2EMEI

Operation 4.0 Operation The swing door operators can be equipped with different programme selectors to control the door operation. The programme selectors PS-2 can be both flush and surface mounted. The PS-3A, can only be flush mounted in the end plate. 4.1 Programme selector PS-2 (key) PS-2 0 1 0 1 PS-2 in position 1 The door opens by means of the motor and is held permanently open. PS-2 in position 0 The permanent hold open function is disconnected and the door closes after the pre-set time delay. The door can be opened with the inner and outer activation units and with key impulse. AAF272EMA 4.2 Programme selector PS-3A PS-3A Auto Normal position. The door can be opened with the activation units. The electric striking plate, if fitted, is locked. Off The door is closed. The outer activation units are disconnected. The electric striking plate, if fitted, is locked. The door can only be opened with key impulse. AAE369 Open The door is held permanently open. FAA077A2EMEI Issued 2006-08-15 7

Safety 5.0 Safety 5.1 Safety functions integrated in the operator Opening A door that is obstructed during the opening movement will try to open until the hold open time has elapsed and then close. Closing A door that is obstructed during the closing movement will stop. When the obstruction is removed the door will continue to close. 8 Issued 2006-08-15 FAA077A2EMEI

Safety 5.2 Safety functions with sensors The EntreMatic active infra-red presence and activation sensor improves the safety for the traffic around and through the automatic swing door. It makes sure that the door is opened automatically, but at the same time it inhibits unwanted movement of the door. The sensor prohibits the door from opening if an obstacle is detected in the zone A or closing if an obstacle is detected in the zone B. If an obstacle is detected during door opening, the door ceases its motion. If an obstacle is detected during door closing, the door will reopen. The sensor detects presence, also stationary objects in the zone are detected. The examples below show an installation with sensors on both sides of the door, but the sensor can also be installed on one side only. B A B A Closed door The unit on the B side, working as an activation unit, gives a signal to the operator to open the door if a person or object enters the detection zone B. The unit on the A side, working as a presence detection unit, prevents the door from opening if an obstacle is present in the detection zone A. B A Opening and closing door During the closing cycle the unit on the B side is working as a presence impulse unit. If a person or an object is detected within the zone B a signal is generated to the door operator to reopen the door. The unit on the A side, prevents the door from reopening if a person or an object is detected within the zone A. B Open door The detection zone A has been disconnected to prohibit activation by the wall. The unit on the B side is now working as a presence impulse unit. If anyone stops in front of the open door closing is prevented. FAA077A2EMEI Issued 2006-08-15 9

Troubleshooting 6.0 Troubleshooting What s wrong The door does not open The motor does not start Remedies Change the setting of the programme selector. (See page 7) Check that there are no objects in the detection zone A, if a sensor is fitted. (See page 9) Check the mains switch. Check the fuses and replace if necessary. (See page 11) The motor starts but stops during opening Unlock the mechanical locks. (See page 6) Check that nothing is jammed beneath the door. The door does not close Change the setting of the programme selector. (See page 7) If presence photocells are fitted, clean the protecting covers. Check that there are no objects in the detection zone B, if a sensor is fitted. (See page 9) Check that nothing is jammed beneath the door. The door does not close continuously Check that there are no moving objects within 1-1,5 m from the door if any automatic activation unit is fitted. 10 Issued 2006-08-15 FAA077A2EMEI

12 1110 9 8 7 Replacement of fuses 7.0 Replacement of fuses 7.1 Removing the cover 1 Disconnect the mains power. 2 Remove the fastening screw (1) at the underside of the cover. 3 The cover is slid over flanges in the end plates (3). Grab around the cover and pull outwards. Note! To obtain sufficient earthing between the mounting plate and the cover, the toothed washer (2) must always be used when the cover is replaced. 3 HSO LSO HSO TB2 701??? LSO Motor control LK LSC HSC HSC LSC 701??? 0 V DC "Slave" control 24 V DC LK 181716151413 6 5 4 3 2 1 1 2 3 4 1234 TB1 AAE274 TB8 1 2 3 4 5 6 7 8 Kill 0 V DC Impulse Lock 24 V DC (+)13-20 V DC Operation enable Operation enable Operation enable Operation enable 1 2 3 4 5 6 7 8 AAF295EMA 2 1 7.2 Replacement of fuses 1 Replace only with the same type and rating of fuse. F2 F1 HSO LSO HSO 701??? LSO AAF294EMA FAA077A2EMEI Issued 2006-08-15 11

Accessories 8.0 Accessories The EntreMatic swing door operators can be equipped with a wide range of standard or optional equipment, some of them stated below. If you wish to upgrade your operator, or add some extra equipment, contact your EntreMatic representative. Programme selectors (See page 7) Radar activators Impulse and presence detection sensors Electric striking plate (lock) Coordination unit, COOA Door stop Fitted above the opening on one or both sides of the door so the door opens on approach. (See page 8) Controlled by the control unit (by others). Ensures that rebated doors closes in correct order. To prevent door from extending beyond 90 degrees. 12 Issued 2006-08-15 FAA077A2EMEI

Accessories FAA077A2EMEI Issued 2006-08-15 13

EntreMatic AB, Box 669, SE-261 25 Landskrona, Tel: +46 418 514 50, Fax: +46 418 511 63, E-mail: info@entrematic.se