DLO1191 Linear smoke detector



Similar documents
DM1101, DM1103, DM1104 DM1103-L, DM1103-S Manual call points Manual release button and emergency stop button

FDCI222, FDCIO222, FDCIO224 Input module Input/output modules

DBS720 / FDS221-R / FDS221-W Sounder base, Alarm sounders

Input module, input/output module

QFP910. Water detector. Building Technologies. CE1N2732en Synco living

Analogue addressable devices

HCR3.2/.. Chipcard reader HOTEL SOLUTION

Beam Detection Systems Application Guide

ABB Stotz-Kontakt GmbH ABB safe&smart Project planning of security systems

Fire detection equipment

Smoke exhaust systems

Highly flexible the right KNX/DALI gateway for every requirement

How To Use A Ds340 (Dsp)

FIRERAY 2000 Installation Guide

RRV934. Multi-controller. Synco living

Optical fiber intrusion detection fence sensor

QFP910. Water detector. Building Technologies. CE1N2732en. Synco living

Detector transparent with Color Inserts. FAA 500 TR P Trim Ring transparent with Color Inserts. FCA 500 / FCA 500 E Detector Bases

Begin using tomorrow s security features today.

Duct Humidity Transmitter

D7050/D7050TH. Installation Instructions. Multiplex Photoelectric Smoke Detectors

SEZ220. Signal Converter. Synco 200. With preprogrammed standard applications Freely programmable Menu-driven operation. Use

BURGLAR ALARM SYSTEMS BURGLAR ALARM SYSTEMS BURGLAR ALARM SYSTEM EURO ALARM WIRELESS BURGLAR ALARM SYSTEM OASIS

Mitel DECT Base Stations

T-SERIES INDUSTRIAL INCLINOMETER ANALOG INTERFACE

FIREDEX Conventional Fire Panels

OPERATING PRINCIPLES FOR PHOTOELECTRIC SENSORS

Triple Waveband Infra-Red Flame Detection

Air damper actuators

CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data.

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

FAAST. Fire Alarm Aspiration Sensing Technology

(68.52) X. June 2000 Supercedes February xenex CONVENTIONAL FIRE DETECTION & ALARM SYSTEM. we business differently

Rousseau 10. User Guide

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

SMART SENSOR COLLECTION

Long sensing range. Most suitable for conveyor lines and parking lot applications. 10 m ft (Red LED)

Hills wireless security alarm DIY range

AXIS T81B22 DC 30W Midspan

Digital inductive conductivity transmitter

PowerCode Wireless. Fully supervised wireless system. Features

FC722 Fire control panel

J TB/TW Temperature limiter, temperature monitor

MINERVA MX MX Virtual Multi-Sensor Detectors

Premier M Plus & Infinity 8

Voltage Regulator SPAU 341 C. Product Guide

FIRE ALARM SYSTEM. reliable fire detection and alarm signalling system

sensors Miniature Sensors - S100 The universal miniature photoelectric sensor

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

720r Addendum: Siting the 720r

Cross-beam scanning system to detect slim objects. 100 mm in

FIRE ALARM SYSTEM TECHNICAL SPECIFICATIONS Page 1 of 10

1 Safety instructions. 2 Device components. 3 Function. Leader in Led solutions. Compact presence detector. Operating instructions

Keys to understanding your alarm system

90 Degree PIR Wireless Security Sensor. Installation Instructions 5420/90F

Installation handbook. AutroBeam 25 Beam detector

Laser diffuse reflection light scanner with background suppression. Dimensioned drawing

A P P L I C A T I O N S G U I D E. Single-Ended Reflective Beam Smoke Detector

Telephone- and leased line modem for industrial applications TD-36

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Building Technologies

TX OPEN RS232/485 module

Fire control panel (modular)

Technical data. General specifications. Signal voltage V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output.

Siemens S-Box: Wireless security for your home.

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

HEAT MONITORING AND CONTROL INSTRUMENTS FOR TRANSFORMERS MB 103 TEMPERATURE CONTROL UNIT PT 100 TEMPERATURE SENSOR

ACS-30-EU-EMDR-10-MOD

Collision Prevention and Area Monitoring with the LMS Laser Measurement System

Rack mounted telephone- and leased line modem for industrial applications

Application and Instruction Manual Motion Activated Solar Powered LED Security Light with Camera MODEL: XP-2H38WC

Owner s Manual

Thyristor-controlled power supplies and battery chargers

Distributed Temperature Sensing - DTS

Cerberus PRO product catalog

Sensing method Appearance a Connection o method Sensing distance Model NPN output PNP output Through-beam Pre-wired (see note 3) Connector.

FC722. Fire control panel. Cerberus PRO. FS720 series, IP6

My first Hirschmann: The SPIDER family of switches.

Technical Manual Functional Description for S800-RSU-H / S800W-RSU 2CCC413022M Schaffhausen 1 / 10

intelligent solutions

Clear Glass Sensor. Ordering Information E3S-CR67/62. Optimum Sensor for Detecting Transparent Glass and Plastic Bottles

Rosemount 333 HART Tri-Loop

Instruction Manual Service Program ULTRA-PROG-IR

How To Use A Flowmeter

PSDC PSDC 12V/8A/8x1A Power supply for up to 8 analog cameras PTC/TOPIC.

Low Frequency Velocity Sensor

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

Smoke Detectors Ordering Information DS230 DS230 Series Heat Detectors DS230F DS233F Peripheral Accessories EOL200 TP280 Bases Features

Passive Infrared Motion Detector 5420/90. Installation Instructions

XUSL4E4BB091NS2 XUSL type 4 - Slave2 - For body protection - 4 Beams, Hp = 910 mm

TEIP11 I/P signal converter for standard signals. Measurement made easy

MPC 4. Machinery Protection Card Type MPC 4 FEATURES. Continuous on-line Machinery Protection Card

HERZ-Thermal Actuators

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features

Power Supplies 3. SDN-P DIN Rail Series

ACCESS CONTROL SECURITY SYSTEMS TRANSMITTERS SHOW-WINDOWS PROTECTION COMPONENTS FOR GATES AUTOMATION

Infrarot-Bewegungsmelder IP44

IN-OUT Thermometer with Cable Free Sensor and Clock

Transcription:

DLO1191 Linear smoke detector collective/synoline600, interactive AlgoRex Synova Reliable smoke detection in large-volume rooms (inside application) Detection distance from 5 100 Meter Efficient signal processing algorithms with characteristics for specific applications Works according to the principle of light attenuation by smoke Selectable response behavior, up to 3 sensitivity levels can be selected Transmission of 4 different danger levels to control unit Signal processing based on the fuzzy logic principle, indicates false alarms, provides remote diagnosis possibilities Automatic compensation for soiling High immunity against extraneous light and electromagnetic influences Transmitter and receiver in one housing Distance measuring between transmitter and receiver Control Products and Systems

Characteristics Environmental ecologically processing recyclable materials electronic und synthetic material simple separable Characteristics the detector and base housing is made of a robust, glass fiber reinforced synthetic material protected electronic built-in alarm indicator self-test function integrated line separator detector heating in case of danger of moisture condensation 3 sensitivity levels and event-controlled detection behavior interactive signal processing 4 danger levels facilitate the initiation of dedicated actions as well as early warning in case of erroneous application 4 function states; in addition to the normal status, the detector signals Information, Interference or Fault, depending on the urgency of the cause collective signal processing the detector signals alarm and fault states to the control unit Function The detector consists of a light emitter and a light receiver. The light emitter emits a bundled infrared ray, which is scattered back by the prism-shaped reflector to the light emitter. The receiver converts the received infrared signal in an electric signal, which is evaluated by the microprocessor-controlled electronics. Smoke penetrating the measuring section attenuates the infrared signal. When the signal reaches predefined measuring values, the detector transmits the corresponding danger level to the control unit. distance measurement for the recognition of foreign matters The built-in alarm indicator signals the alarm status locally. Detector Reflector Receiver Distance measuring Transmitter Max. detection distance 5 100 m Environmental influences digital signal follower circuit Gradual changes in the infrared signal received owing to dust on the lens or the detector automatically compensates other environmental influences. multiple coincidence circuit Suppresses electrical and optical interference signals. The DLF1191-AC filter is provided in the event of particularly strong incidence of extraneous light. prism-shaped reflectors light rays arriving are reflected parallel vibrations of the installation surface have no effect on the detector 2

Application large store-rooms and production workshops areas with complex roof structures or historically valuable ceilings covered courtyards atrium-type buildings reception halls Accessories Reflector for long distance Reflector for short distance Detector heating element (Prism) DLR1191 DLR1193 DLH1191A Adjustment set FDLU291 (incl. Front sight, Visor, Alarm test filter, Magnet, FCC spiral cable, MC-Link cable) Reflector for middle distance DLR1192 Special filters DLF1191-AA/-AB/-AC Installation Easy mounting of the housing on stable surfaces; wood and steel constructions are rather unsuitable as temperature and humidity fluctuations, wind or snow pressure may exert an influence. 6 openings with M20 thread for cable glands ext. alarm indicator connectable Between the detector and the reflector there must be permanent, unhindered visual contact. Obscuration by operational dust, vapor or smoke generation may impair the system. Any objects in motion, e.g. overhead traveling cranes, ladders, portable items, cobwebs etc, must not interrupt the monitoring ray. The optics can be rationally adjusted to the reflector by single-handed alignment by means of the adjustment device FDLU291. For various distances, different reflectors are available. Dimensions Base DLB1191A Reflector DLR1191 Reflector DLR1192/93 M20 100 200 115 65 2,5 100 200 Detector unit DLA1191A 3

Technical data Detector Load factor KMK IMK Alarm indicator (AI) ext. connectable and programmable Detection distance 25 (max. 1 detector per detector line) 10 (Condition: separator connection factor = 1) 2 5 100 m Operating temperature -25 +60 C Storage temperature -30 +75 C Humidity 95 % rel. Connection terminals 0.2 1.5 mm 2 (AWG24 15) Color white, ~RAL 9010 Protection category IP65 EN 60529 / IEC 60529 Standards EN 54-12, EN 54-17, EN 62471 Approvals VdS LPCB System compatibility Detector heating Operating voltage DC 20 30 V Operating current 30 50 ma Resistor 600 Ω G296032 126bd/01 Compatible with all fire detection system control units with interactive and collective/synoline600 signal evaluation 4

Details for ordering Type Part no Designation Weight DLA1191A BPZ:4942920001 Linear smoke detector unit 0.440 kg DLB1191A BPZ:4692010001 Base 0.305 kg A5Q00004478 Metal screwed cable gland M20 x 1.5 0.039 kg DLF1191-AA BPZ:4933030001 Filters for distances of 7 10 m 0.005 kg DLF1191-AB BPZ:4933160001 Filters for distances of 5 8 m 0.005 kg DLF1191-AC BPZ:5221480001 Filter against incidence of extraneous 0.005 kg light DLH1191A BPZ:4787970001 Detector heating element 0.010 kg DLR1191 BPZ:4787710001 Reflector for long distance (Prism, 20-100 m) 0.510 kg DLR1192 BPZ:4788490001 Reflector for middle distance (400 cm 2, 30-65 m) 0.075 kg DLR1193 BPZ:4787840001 Reflector for short distance (100 cm 2, 10-30 m) 0.025 kg FDLU291 A5Q00004905 Adjustment set incl. accessories (case) 0.840 kg RE10 BPZ:3685190001 Detector tester for linear smoke detectors 0.345 kg Alarm test filter for RE10 TF04 BPZ:4931090001 Alarm test filter (Absorption 77 %) 0.005 kg (is also included in Adjustment set FDLU291) 5

Issued by Siemens Switzerland Ltd Division International Headquarters Gubelstrasse 22 CH-6301 Zug Tel. +41 41 724 24 24 www.siemens.com/buildingtechnologies Siemens Switzerland Ltd, 2015 Technical specifications and availability subject to change without notice. Document no. 001270_o_en_-- Manual S11 / FD-C Edition 2016-04-20 Section 5