PARTS CATALOG OUTDOOR UNIT. No. OBB516. Models



Similar documents
PARTS CATALOG MUZ-HJ25VA - E1, ER1, ET1 MUZ-HJ35VA - E1, ER1, ET1 MUZ-HJ50VA - E1, ER1, ET1 OUTDOOR UNIT. No. OBB648 REVISED EDITION-C.

SERVICE MANUAL MUZ-GE25VA - E1 MUZ-GE25VAH - E1 MUZ-GE35VA - E1 MUZ-GE35VAH - E1 MUZ-GE42VA - E1 MUZ-GE42VAH - E1 MUZ-GE50VA - E1 MUZ-GE50VAH - E1

PARTS CATALOG MSZ-FH25VE MSZ-FH35VE MSZ-FH50VE INDOOR UNIT. No. OBB623. Models

SERVICE MANUAL OUTDOOR UNIT. No. OBH590 REVISED EDITION-B. Models HFC

SERVICE MANUAL MUZ-GE09NA MUZ-GE12NA MUZ-GE15NA MUZ-GE18NA MUZ-GE24NA MUY-GE09NA MUY-GE12NA MUY-GE15NA MUY-GE18NA MUY-GE24NA OUTDOOR UNIT

Indoor coil is too warm in cooling mode or too cold in heating mode. Reversing valve or coil thermistor is faulty

SERVICE MANUAL INDOOR UNIT

CONTENTS 1. IMPORTANT NOTICE 2 2. TECHNICAL SPECIFICATION 3 3. OPERATION DETAILS 4 4. WIRING DIAGRAM EXPLOSION VIEW 12 6.

SERVICE MANUAL MU-A09WA MU-A12WA MU-A12WA- 1 OUTDOOR UNIT. No. OB449. Wireless type Models HFC. Revision : A SPLIT-TYPE AIR CONDITIONERS

SERVICE MANUAL MUZ-FE09NA MUZ-FE12NA MUZ-FE18NA OUTDOOR UNIT. No. OBH543 REVISED EDITION-A. Models HFC

SERVICE MANUAL OUTDOOR UNIT MUZ-A09NA,- 1,- U1,- U2 MUZ-A12NA,- U1 MUZ-A15NA,- U1 MUZ-A17NA,- U1 MUY-A15NA MUY-A17NA MUY-A24NA,- 1,- U1,- U2

PACKAGE AIR CONDITIONERS REPLACEMENT PARTS MANUAL

SERVICE MANUAL MUZ-HJ25VA MUZ-HJ35VA OUTDOOR UNIT. No. OBH648. Models HFC SPLIT-TYPE AIR CONDITIONERS R410A

SERVICE MANUAL MSZ-A18YV - E1 MSZ-A24YV - MSZ-A24YV - E1 INDOOR UNIT. No. OB345 REVISED EDITION-A. Models. Revision A : SPLIT-TYPE AIR CONDITIONERS

technical data air conditioning systems RXS E (single phase) FBQ-B8V1-B8V3B Split Heat Pump Condensing Units Split Sky Air

Failure code manual. content

WALL MOUNTED PACKAGE HEAT PUMPS REPLACEMENT PARTS MANUAL WH483 WH602. Contents. General Notes. Important. Description

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS

NSN

SERVICE MANUAL SPLIT SYSTEM ROOM AIR CONDITIONER SHARP CORPORATION SHARP CORPORATION CONTENTS

SERVICE MANUAL. Room Air Conditioner Multi Split type Outdoor unit /R410A DC Inverter/

SERVICE MANUAL INDOOR UNIT

HP switch LP switch Discharge thermo Comp. Surface thermo

NO-FROST CUSTOMER SUPPORT INFORMATION INFORMATION ON THE NO-FROST TECHNOLOGY WHITE GOODS

SERVICE MANUAL MUZ-GC25VA - MUZ-GC25VAH - MUZ-GC35VA - MUZ-GC35VAH - E1 OUTDOOR UNIT. No. OBH469. Wireless type Models HFC

Air Conditioners. Technical Data. Wall Mounted Unit. RX-JV/GV

Room Air Conditioner SVC MANUAL(Exploded View)

TAS-18MVHN/O TAS-27MVHN/O TAS-36MVHN/O

Models: Contents. Cabinet Components. Functional Components " Exploded View... 3 " Usage List Control Panel. Blower Housing

Models: WA182, WA242. Contents. Cabinet Components. Functional Components " Exploded View... 3 " Usage List Control Panel.

28 REPLACEMENT PARTS INDOOR UNIT CS-W18BD3P, CS-W24BD3P, CS-W28BD3P

Model: AC-S13CG x 2. Model No: AC-S13CGx2.doc Version 1.0


SERVICE MANUAL MXZ-2A20NA MXZ-2A20NA - MXZ-3A30NA MXZ-3A30NA - MXZ-4A36NA OUTDOOR UNIT. No. OB444. Models HFC. Inverter-controlled multi system type

Service & Parts Manual

SERVICE MANUAL MSZ-HJ25VA MSZ-HJ35VA MSZ-HJ50VA INDOOR UNIT. No. OBH647. Models. Revision A: MSZ-HJ50VA- E1 has been added.

SERVICE MANUAL INDOOR UNIT MSZ-EF35VEW MSZ-EF22VEB - - E1 MSZ-EF25VEB E1 MSZ-EF35VEB - - E1 MSZ-EF35VEB E1 MSZ-EF35VES - E1 - E1 MSZ-EF22VEW -

PRE-ASSEMBLED REMOTE REFRIGERATION SYSTEMS

R22. K Control. Indoor Unit. Nomenclature. Compatibility PL H 3 G K H B. Unit style Heat Pump Horse Power

Technical service manual

13. Troubleshooting. Indoor unit s LED indication of Corona DC inverter unit. Indoor unit s LED indication of Alfa DC inverter unit

MDT5N25 & MTD5N40 SERVICE PARTS

CLOSE CONTROL SYSTEM. PFD series provide you with highly reliable computer room cooling system. High Reliability

How To Power A Car With A Fan And A Fan (Power)

Split-type Air-Conditioner INSTALLATION MANUAL CONTENTS FOR INSTALLER MXZ-3A30NA MXZ-4A36NA ATTENTION. English. Français. Español

Heating, Ventilation, Air Conditioning and Refrigeration (HVACR)

SERVICE MANUAL INDOOR UNIT. No. OB450. Models. Revision D: SPLIT-TYPE AIR CONDITIONERS REVISED EDITION-D

CONTENTS 1. IMPORTANT NOTICE 2 2. TECHNICAL SPECIFICATION 3 3. OPERATION DETAILS 4 4. ELECTRICAL SCHEMATIC DIAGRAM EXPLOSION VIEW 16 6

TECHNICAL SUPPORT MANUAL 3 Phase Air Conditioner Component R2A3**GHR

REPLACEMENT PARTS LIST Single Package Air Conditioner (*)P3 Series 10 SEER and 12 SEER Models

Condensing unit type EPSILON-ECHOS LE Technical information manual

Service manual. Website: CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL.

How To Measure Temperature On A Thermostat

PANASONIC TROUBLE SHOOTING GUIDE

TWE+TTA TWE+TWA T.R.

DC INVERTER MULTI-SYSTEM AIR CONDITIONER

MAKING MODERN LIVING POSSIBLE. Wiring Diagram DHP-R.

Technical service manual 2009

Si10-417_C. Pocket Manual. Service Diagnosis SPLIT & MULTI

Repair Guideline for TCL DC Inverter Air Conditioner

Table Z. Troubleshooting Chart for Air Conditioners. Cause

TECHNICAL & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER + SAP C181MA + SAP C181GA + SAP C181BA + SAP C241MA + SAP C241BA FILE NO.

Chapter 5. Components, Symbols, and Circuitry of Air-Conditioning Wiring Diagrams

Split units TH with hermetic compressors

SECTION MORTUARY REFRIGERATORS

Local Dealer:

WALL MOUNTED PACKAGE AIR CONDITIONER REPLACEMENT PARTS MANUAL W70A1 W70L1. Models: Contents. General Notes. Important. Description

SECTION HEAT PUMPS

ABNORMAL OPERATION Error code Display. Specifics Error Code. Subsection Error Code. Subsection and Specifics Error code target

SERVICE MANUAL MSZ-FD25VA - MSZ-FD25VAS - MSZ-FD35VA - MSZ-FD35VAS - MSZ-FD50VA - MSZ-FD50VAS - INDOOR UNIT. No. OBH488. Models

Air Conditioners Technical Data

SWIMMING POOL HEAT PUMP

ROOFTOP - HEAT PUMP UNIT. This document applies when installing into an air handler or as part of an air handling system.

Split air conditioner Wall mounted Type. Service manual

Split air conditioner Wall mounted Type Service manual

HITACHI INVERTER-DRIVEN MULTI-SPLIT SYSTEM HEAT PUMP AIR CONDITIONERS

HYUNDAI SERVICE MANUAL HSH-I183NBE. Models WALL MOUNTED SPLIT-TYPE AIR CONDITIONERS. No.TE121023

THERMO KING TRUCK & TRAILER UNIT ALARM CODES THIS DOCUMENT SHOWS ALL CURRENT ALARM CODES FOR THERMO KING TRUCK AND TRAILER UNITS.

Portable Air Conditioner

HVAC-02, Air Conditioning Troubleshooting and Repair

HEATER, AIR CONDITIONING AND VENTILATION

Split System Heat Pump Product Data

SERVICE INSTRUCTION R410A. SPLIT TYPE ROOM AIR CONDITIONER Universal Floor / Ceiling Duct / Cassette Wall Mounted / Floor type INVERTER MULTI

SERVICE MANUAL REFRIGERATION

Air-sourced 90 Hot Water Supplying Heat Pump "HEM-90A"

10.1 Indoor Unit Error Display

Guidelines with preventive maintenance schedule. Value up guidelines

Midea Commercial Air Conditioner Malfunction Handbook

Reverse Cycle Inverter Split System Air Conditioner

SWIMMING POOL HEAT PUMP Owners Manual

SERVICE & MAINTENANCE MANUAL

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

Elements Elements describe the essential outcomes. 1. Prepare to diagnose and repair air conditioning and HVAC system

VRV Systems Basic Operation Guide

innovative comfort solutions

HEAT PUMP FREQUENTLY ASKED QUESTIONS HEAT PUMP OUTDOOR UNIT ICED-UP DURING COLD WEATHER:

DC INVERTER MULTI-SYSTEM AIR CONDITIONER

Heat Pump Water Heater IOM Manual

Split System Air Conditioners SkyAir Inverter

Table V. Troubleshooting Checklist for Refrigeration Systems. Air or non-condensable gas in system. Inlet water warm.

Transcription:

SPLIT-TYPE AIR CONDITIONERS Revision D: The fan guards for MUZ-GE50VA(H) - E, MUZ -GE60VA - E and MUZ-GE7VA - E have been changed. Please void OBB56 REVISED EDITION-C. OUTDOOR UNIT PARTS CATALOG No. OBB56 REVISED EDITION-D Models MUZ-GE25VA - E MUZ-GE60VA - E MUZ-GE25VAH - E MUZ-GE7VA - E MUZ-GE35VA - E MUZ-GE35VAH - E MUZ-GE42VA - E MUZ-GE42VAH - E MUZ-GE50VA - E MUZ-GE50VAH - E MUZ-GE25VA MUZ-GE35VA MUZ-GE42VA CONTENTS. RoHS PARTS LIST 2 SERVICE MANUAL (OBH56) NOTE: RoHS compliant products have <G> mark on the spec name plate.

Revision A: MUZ-GE42VA - E, MUZ-GE42VAH - E, MUZ-GE50VA - E and MUZ-GE50VAH - E have been added. Revision B: MUZ-GE60VA - E and MUZ-GE7VA - E have been added. Revision C: Part numbers of reactors for MUZ-GE60VA - E and MUZ-GE7VA - E have been changed. (E2 85 337 E2 F28 337) Revision D: The fan guards for MUZ-GE50VA(H) - E, MUZ-GE60VA - E and MUZ-GE7VA - E have been changed. RoHS PARTS LIST MUZ-GE25VA MUZ-GE25VAH MUZ-GE35VA MUZ-GE35VAH MUZ-GE42VA MUZ-GE42VAH -. OUTDOOR UNIT STRUCTURAL PARTS AND FUNCTIONAL PARTS 23 20 9 8 7 5 4 0 9 2 6 24 22 3 2 2 3 4 5 6 7 8 2

-. OUTDOOR UNIT STRUCTURAL PARTS AND FUNCTIONAL PARTS Part numbers that are circled are not shown in the illustration. No. RoHS Part No. Part Name Symbol in Wiring Diagram Q'ty/unit MUZ-GE25 MUZ-GE35 MUZ-GE42 VA VAH- VA VAH VA VAH - E E - E - E - E - E G E2 927 232 CABINET 2 G E2 927 52 GRILLE 3 G E2 927 50 PROPELLER Remarks 4 G E2 D69 290 BASE G E2 D70 290 G E2 D69 900 KNB073FFDHC 5 G E2 D70 900 COMPRESSOR MC KNB092FFAHC G E2 E05 900 SNB30FGBHT 6 G E2 065 506 COMPRESSOR RUBBER 3 3 3 3 G E2 C34 506 SET 3 3 3 RUBBERS/SET 7 G E2 D69 66 STOP VALVE (GAS) G E2 927 66 ø9.52 8 G E2 D58 662 STOP VALVE (LIQUID) G E2 927 662 ø6.35 9 G E2 927 245 SERVICE PANEL 0 G E2 927 233 BACK PANEL G E2 C37 233 G E2 927 640 EXPANSION VALVE G E2 838 640 2 G E2 927 493 EXPANSION VALVE COIL LEV 3 G E2 D65 96 4-WAY VALVE 4 G E2 928 079 THERMO HOLDER G E2 930 079 5 G E2 928 525 CONDENSER WIRE NET G E2 930 525 6 G E2 B83 523 CONDENSER NET G E2 929 523 7 G E2 928 523 CONDENSER NET G E2 930 523 G E2 D69 293 8 G E2 D77 293 SEPARATOR G E2 C34 293 G E2 C36 293 9 G E2 927 55 MOTOR SUPPORT G E2 929 55 20 G E2 927 297 TOP PANEL G E2 D69 630 OUTDOOR HEAT 2 G E2 D70 630 EXCHANGER 22 G E2 D69 30 RC0J50- OUTDOOR FAN MOTOR MF G E2 C34 30 RC0J50-23 G E2 C36 526 DEFROST HEATER H 24 G E2 C36 38 HEATER PROTECTOR 26H 25 G E2 927 937 CAPILLARY TUBE ø3.0 ø2.0 240 26 G E2 735 936 CAPILLARY TUBE 2 2 2 2 ø3.0 ø.8 600 27 G E2 838 704 DRAIN SOCKET 3

MUZ-GE25VA MUZ-GE25VAH MUZ-GE35VA MUZ-GE35VAH MUZ-GE42VA MUZ-GE42VAH -2. OUTDOOR UNIT ELECTRICAL PARTS 0 9 8 7 6 5 2 3 4 4

-2. OUTDOOR UNIT ELECTRICAL PARTS Symbol Q'ty/unit No. Part No. Part Name in Wiring MUZ-GE25 MUZ-GE35 MUZ-GE42 Remarks Diagram VA- E VAH- E VA- E VAH- E VA- E VAH- E G E2 B72 337 REACTOR L6 G E2 838 337 2 G E2 C34 306 THERMISTOR SET RT6, RT62 DEFROST, DISCHARGE 3 G E2 927 308 AMBIENT TEMPERA- RT65 RoHS TURE THERMISTOR OUTDOOR HEAT EX- 4 G E2 C34 307 CHANGER TEMPERA- TURE THERMISTOR RT68 5 G E2 C34 490 R.V. COIL 2S4 6 G E2 735 24 FUSE HOLDER 7 G E2 735 382 FUSE F6 T20AL250V 8 G E2 D69 374 TERMINAL BLOCK TB 3 P 9 G E2 D70 374 TERMINAL BLOCK TB2 3 P 0 G E2 D69 45 G E2 D77 45 G E2 D70 45 INVERTER P.C. BOARD G E2 D78 45 G E2 E03 45 G E2 E04 45 Including heat sink and RT64 5

MUZ-GE50VA MUZ-GE50VAH -3. OUTDOOR UNIT STRUCTURAL PARTS, ELECTRICAL PARTS AND FUNCTIONAL PARTS 30 29 28 27 26 25 24 23 22 2 3 4 5 9 20 2 6 8 7 8 6 5 7 3 4 9 0 2 6

-3. OUTDOOR UNIT STRUCTURAL PARTS, ELECTRICAL PARTS AND FUNCTIONAL PARTS Part numbers that are circled are not shown in the illustration. No. RoHS Part No. Part Name Symbol in Wiring Diagram Q'ty/unit MUZ-GE 50VA- E 50VAH- E Remarks G E2 89 297 TOP PANEL 2 G E2 D84 630 OUTDOOR HEAT EXCHANGER 3 G E2 938 30 OUTDOOR FAN MOTOR MF RC0J60-4 G E2 85 50 PROPELLER 5 G E2 D86 290 BASE G E2 D84 290 6 G E2 89 232 CABINET 7 G E2 89 009 HANDLE 8 G E2 D84 52 FAN GUARD Including ice guard 9 G E2 C34 506 COMPRESSOR RUBBER SET 3 3 3 RUBBERS/SET 0 G E2 E05 900 COMPRESSOR MC SNB30FGBHT G E2 D58 66 STOP VALVE (GAS) ø2.7 2 G E2 D58 662 STOP VALVE (LIQUID) ø6.35 3 G E2 85 640 EXPANSION VALVE 4 G E2 E05 493 EXPANSION VALVE COIL LEV 5 G E2 D58 490 R.V. COIL 2S4 6 G E2 C8 96 4-WAY VALVE 7 G E2 89 650 VALVE COVER 8 G E2 89 245 SERVICE PANEL 9 G E2 E05 308 THERMISTOR SET RT6,RT62 DEFROST, DISCHARGE 20 AMBIENT TEMPERATURE G E2 D58 309 THERMISTOR RT65 2 G E2 E05 307 OUTDOOR HEAT EXCHANGER TEMPERATURE THERMISTOR RT68 22 G E2 735 24 FUSE HOLDER 23 G E2 735 382 FUSE F6 T20AL250V 24 G E2 D69 374 TERMINAL BLOCK TB 3 P 25 G E2 D70 374 TERMINAL BLOCK TB2 3 P 26 G E2 E05 45 INVERTER P.C. BOARD G E2 E06 45 Including heat sink and RT64 27 G E2 D58 337 REACTOR L6 28 G E2 E09 233 BACK PANEL (OUT) G E2 E06 233 29 G E2 87 009 HANDLE 30 G E2 85 55 MOTOR SUPPORT 3 G E2 853 936 CAPILLARY TUBE (TAPER PIPE) ø3.6 ø2.4 50 32 G E2 E05 38 HEATER PROTECTOR 26H 33 G E2 E05 526 DEFROST HEATER H 34 G E2 87 704 DRAIN SOCKET 35 G E2 444 705 DRAIN CAP 2 7

MUZ-GE60VA MUZ-GE7VA -4. OUTDOOR UNIT STRUCTURAL PARTS, ELECTRICAL PARTS AND FUNCTIONAL PARTS 28 27 26 24 23 22 2 3 4 25 20 9 2 5 6 6 8 5 7 4 3 7 8 2 9 0 8

-4. OUTDOOR UNIT STRUCTURAL PARTS, ELECTRICAL PARTS AND FUNCTIONAL PARTS Part numbers that are circled are not shown in the illustration. Symbol Q'ty/unit No. Part No. Part Name in Wiring MUZ-GE Remarks Diagram 60VA- E 7VA- E G E2 F28 297 TOP PANEL G E2 F28 630 OUTDOOR HEAT EXCHANGER 2 G E2 F29 630 OUTDOOR HEAT EXCHANGER 3 G E2 F28 30 OUTDOOR FAN MOTOR MF RC0J60-4 G E2 F28 50 PROPELLER 5 G E2 87 009 HANDLE 6 G E2 F28 232 CABINET 7 G E2 F73 52 FAN GUARD Including ice guard 8 G E2 F28 290 BASE 9 G E2 C34 506 COMPRESSOR RUBBER SET 3 3 3 RUBBERS/SET 0 G E2 F28 900 COMPRESSOR MC SNB30FGBMT G E2 F29 900 COMPRESSOR MC SNB72FEKMT G E2 F28 66 STOP VALVE (GAS) ø5.88 2 G E2 F28 662 STOP VALVE (LIQUID) ø6.35 G E2 F29 662 STOP VALVE (LIQUID) ø9.52 3 G E2 85 640 EXPANSION VALVE G E2 853 640 EXPANSION VALVE 4 G E2 F28 493 EXPANSION VALVE COIL LEV 5 G E2 F28 490 R.V. COIL 2S4 6 G E2 C8 96 4-WAY VALVE 7 G E2 F28 650 VALVE COVER 8 G E2 F28 245 SERVICE PANEL 9 G E2 F28 079 THERMO HOLDER RoHS 20 G E2 F28 308 THERMISTOR SET RT6,RT62, RT68 DEFROST, DISCHARGE, OUTDOOR HEAT EXCHANGER TEMPERATURE 2 AMBIENT TEMPERATURE G E2 F28 309 THERMISTOR RT65 22 G E2 F29 374 TERMINAL BLOCK TB 3 P 23 G E2 F28 374 TERMINAL BLOCK TB2 3 P 24 G E2 F3 45 INVERTER P.C. BOARD G E2 F32 45 Including heat sink and RT64 25 G E2 F28 233 BACK PANEL (OUT) 26 G E2 F28 337 REACTOR L 27 G E2 F28 523 CONDENSER NET 28 G E2 F28 55 MOTOR SUPPORT 29 G E2 527 936 CAPILLARY TUBE ø4.0 ø2.4 00 30 G E2 F28 704 DRAIN SOCKET 9

0

HEAD OFFICE: TOKYO BLDG., 2-7-3, MARUNOUCHI, CHIYODA-KU, TOKYO 00-830, JAPAN Copyright 2008 MITSUBISHI ELECTRIC CO.,LTD Distributed in Jun. 200. No. OBB56 REVISED EDITION-D 5 Distributed in Jan. 200. No. OBB56 REVISED EDITION-C 5 Distributed in Oct. 2009. No. OBB56 REVISED EDITION-B 5 Distributed in Dec. 2008. No. OBB56 REVISED EDITION-A 5 Distributed in Aug. 2008. No. OBB56 6 Made in Japan New publication, effective Jun. 200 Specifications subject to change without notice.