THERMAL AND ELECTRODYNAMIC CHARACTERISTICS OF ELECTRICAL CONTACTS IN STEADY STATE



Similar documents
Calculation of the Current Transformer Accuracy Limit Factor Application Note

Solution for Homework #1

Resistivity. V A = R = L ρ (1)

Module 1 : Conduction. Lecture 5 : 1D conduction example problems. 2D conduction

Modeling of Transmission Lines

Lecture 9, Thermal Notes, 3.054

Carbon Cable. Sergio Rubio Carles Paul Albert Monte

CHAPTER 7 DISLOCATIONS AND STRENGTHENING MECHANISMS PROBLEM SOLUTIONS

EARTHING SYSTEM CALCULATION

Differential Relations for Fluid Flow. Acceleration field of a fluid. The differential equation of mass conservation

Determination of Thermal Conductivity of Coarse and Fine Sand Soils

9. Force Measurement with a Strain gage Bridge

Stability of Evaporating Polymer Films. For: Dr. Roger Bonnecaze Surface Phenomena (ChE 385M)

PREDICTING THE THERMAL CONDUCTIVITY OF ALUMINIUM ALLOYS AT CRYOGENIC TEMPERATURES. 1 Introduction. 2 The Problem

Chapter 11. Inductors ISU EE. C.Y. Lee

TEXTILE FABRICS AS THERMAL INSULATORS

Chapter 5. Second Edition ( 2001 McGraw-Hill) 5.6 Doped GaAs. Solution

Second Order Linear Partial Differential Equations. Part I

Lecture 24 - Surface tension, viscous flow, thermodynamics

( ) = ( ) = {,,, } β ( ), < 1 ( ) + ( ) = ( ) + ( )

Temperature coefficient of resistivity

49 Series - Relay interface modules A. Features

The Three Heat Transfer Modes in Reflow Soldering

Chapter Outline Dislocations and Strengthening Mechanisms

AS COMPETITION PAPER 2007 SOLUTIONS

POROUS BURNER - A New Approach to Infrared

Rate of Heating Analysis of Data Centers during Power Shutdown

Mohr s Circle. Academic Resource Center

Section 16: Neutral Axis and Parallel Axis Theorem 16-1

48 SERIES Relay interface modules 10 A

CHAPTER 26 ELECTROSTATIC ENERGY AND CAPACITORS

Forces on Large Steam Turbine Blades

Master Panel 1000 W Wall

Lecture 3 Fluid Dynamics and Balance Equa6ons for Reac6ng Flows

Viscous flow in pipe

Force measurement. Forces VECTORIAL ISSUES ACTION ET RÉACTION ISOSTATISM

Peltier Application Note

CURRENT ELECTRICITY - I

Cable Size Selection for Energy Efficiency

2/20/ Transmission Lines and Waveguides.doc 1/3. and Waveguides. Transmission Line A two conductor structure that can support a TEM wave.

Swissmetro travels at high speeds through a tunnel at low pressure. It will therefore undergo friction that can be due to:

PREDICTION OF DISTORTIONS IN THROUGH HARDENING OF CYLINDRICAL STEEL WORKPIECES BY DIMENSIONAL ANALYSIS

Chapter 2: Solar Radiation and Seasons

The Effect of Forced Air Cooling on Heat Sink Thermal Ratings

Basic Equations, Boundary Conditions and Dimensionless Parameters

Lecture 5 Hemodynamics. Description of fluid flow. The equation of continuity

CH 6: Fatigue Failure Resulting from Variable Loading

The soot and scale problems

ME Heat Transfer Laboratory. Experiment No. 7 ANALYSIS OF ENHANCED CONCENTRIC TUBE AND SHELL AND TUBE HEAT EXCHANGERS

Integration of a fin experiment into the undergraduate heat transfer laboratory

Master Panel 1000 R5 Roof

POURING THE MOLTEN METAL

Experiment 3 Pipe Friction

PTYS/ASTR 206 Section 2 Spring 2007 Homework #2 (Page 1/5) NAME: KEY

Technology of EHIS (stamping) applied to the automotive parts production

Steady Heat Conduction

1 Wetting your feet. 2 Scaling Lies / Check your understanding: Solutions

A METHOD OF CALIBRATING HELMHOLTZ COILS FOR THE MEASUREMENT OF PERMANENT MAGNETS

Mounting Instructions for SP4 Power Modules

Errors Related to Cable Resistance Imbalance in Three Wire RTDs

Experimental study of a parabolic solar concentrator

A LAMINAR FLOW ELEMENT WITH A LINEAR PRESSURE DROP VERSUS VOLUMETRIC FLOW ASME Fluids Engineering Division Summer Meeting

PROPER SELECTION OF CONTROL CIRCUIT TRANSFORMERS WHITE PAPER BULLETIN 1497, 1497A, AND 1497B

Ampacity simulation of a high voltage cable to connecting off shore wind farms

Local buckling of plates made of high strength steel

R-Value and Thermal Conductivity of PEX and PE-RT TR-48/2014

This paper is also taken for the relevant Examination for the Associateship. For Second Year Physics Students Wednesday, 4th June 2008: 14:00 to 16:00

THERMAL RADIATION (THERM)

6 ELECTRICAL PARAMETERS

Numerical Analysis of Transient Phenomena in Electromagnetic Forming Processes

Wind Turbine Power Calculations

Fluid Mechanics: Static s Kinematics Dynamics Fluid

Examples of magnetic field calculations and applications. 1 Example of a magnetic moment calculation

THE IMPACT OF YIELD STRENGTH OF THE INTERCONNECTOR ON THE INTERNAL STRESS OF THE SOLAR CELL WITHIN A MODULE

Coupling Effect in Substation Ground Measurements

NUMERICAL SIMULATION OF BIOHEAT TRANSFER PROCESS IN THE HUMAN EYE USING FINITE ELEMENT METHOD

Spray water cooling heat transfer under oxide scale formation conditions

MOTION SENSOR PIR LIGHT SWITCH INSTALLATION & OPERATING. Cat No. ZV810 INSTRUCTIONS

PRODUCT SPECIFICATION

POWER AND DECORATIVE SOLAR FAÇADES

Structural fire design Eurocode Timber structures

DATA SHEET THICK FILM CHIP RESISTORS Introduction

Chapter 16. Mensuration of Cylinder

RAMAX S Prehardened stainless holder steel

2.2. Basic Equations for Heat Exchanger Design

Thermal Resistance, Power Dissipation and Current Rating for Ceramic and Porcelain Multilayer Capacitors

Goodsky Technical Data. Contact Details

40 Series - Miniature PCB/Plug-in relays A. Features

New Methods of Testing PCB Traces Capacity and Fusing

Chapter 6. Current and Resistance

Chapter 10. Flow Rate. Flow Rate. Flow Measurements. The velocity of the flow is described at any

Figure 1: Typical S-N Curves

Application Note, V1.0, 2008 AN Thermal equivalent circuit models. replaces AN Industrial Power

Material data sheet. EOS StainlessSteel GP1 for EOSINT M 270. Description, application

Power Dissipation Considerations in High Precision Vishay Sfernice Thin Film Chips Resistors and Arrays (P, PRA etc.) (High Temperature Applications)

Theory of Heating by Induction

Department of Engineering Enzo Ferrari University of Modena and Reggio Emilia

Transcription:

POZNAN UNIVE RSITY OF TE CHNOLOGY ACADEMIC JOURNALS No 74 Electrical Engineering 2013 Andrzej KSIĄŻKIEWICZ* Ryszard BATURA* THERMAL AND ELECTRODYNAMIC CHARACTERISTICS OF ELECTRICAL CONTACTS IN STEADY STATE In this paper results of theoretical analysis of the thermal and electrodynamic characteristics of electrical contacts are presented. Influences of contact material on temperature changes are discussed. Real contact area impact on electrodynamics of electrical contacts is analysed 1. ELECTRICAL CONTACTS AND CONTACT MATERIALS Electrical contacts are exposed to various hazards during their life cycle. Those hazardous phenomena include thermal and electro dynamical risks. In order for the electrical contacts to work properly for a long time it is necessary to calculate the influence of those phenomenons. To analytically present them many simplifying assumptions have to be made because of the complexity of considered issues. Many different materials are used for electrical contacts. These materials include Ag, AgNi, AgSnO 2 and AgCdO. The first two of them are discussed in this paper. Both of them can be used in low power electromagnetic relays, but the dominant material is AgNi. 2. THERMAL CHARACTERISTICS OF ELECTRICAL CONTACTS 2.1. Thermal theoretical model In order to analyse thermal characteristic of electrical contact in steady state a simple model will be used (Fig. 1). This model represents the contact spot between two connected conductors. In this model the presented temperatures are as follows: τ p steady temperature rise at x = (away from the contact spot), τ z steady temperature rise at x = 0, Δτ additional temperature rise as result of higher current density in the contact spot. The additional temperature rise is a result of reduced cross section of the contact spot, which is many times smaller that the real contact size. * Poznań University of Technology.

138 Andrzej Książkiewicz, Ryszard Batura The temperature distribution in a conductor with a contact spot is described by [1]: 1 ax τ x = I 2 1 Rz e + τ p (1) 2 asλ where: I nominal current, R contact resistance, λ - thermal conductivity, and a and τ p are [1]: τ p kod S a = λs 2 I ρ 1 = S k S where: k od - heat transfer coefficient, S contact spot cross-section, S p1 lateral surface of a dx element of the conductor (in the discussed case is equal to 2πr), ρ contact material electrical resistivity. od p1 p1 (2) (3) Fig. 1. Temperature distribution in electric conductor with contact spot: τ p steady temperature rise at x = (away from the contact spot), τ z steady temperature rise at x = 0, Δτ additional temperature rise[1] The additional temperature rise in steady state is described by [1]: 2 2 I R Δτ (4) 8λρ The additional temperature rise should not be greater than 10 20 K [3]. 2.2. Results of thermal characteristics calculations The presented calculations were made for two different contact materials: Ag and AgNi, and two different contact resistance R z. The parameters used: I = 10 A, k od = 1, r = 1,5 mm (for the S and S p1 ). Contact material electrical resistivity equals:

Thermal and electrodynamic characteristics of electrical contact... 139 ρ Ag = 1,65 10-8 Ωm [4] and ρ AgNi = 1,88 10-8 Ωm [2], thermal conductivity: λ Ag = 4,18 10-2 W/m K, λ AgNi = 3,83 10-2 W/m K. Electric contact resistance R z was taken as the minimum and maximum described in [5] (R zmin = 2,07 mω, R zmax = 7,88 mω). Results of the calculations are presented in Table 1. Table 1. Temperature value depending on contact material and contact resistance Contact resistance R = 2,07 mω Material τ p τ z Δτ τ max [ºC] [ºC] [ºC] [ºC] Ag 24,77 44,35 6,93 51,28 AgNi 28,22 46,97 6,57 53,54 Contact resistance R = 7,88 mω Ag 24,77 99,40 88,89 188,29 AgNi 28,22 99,68 84,61 184,29 The steady temperature rise τ p is equal for both of the contact resistances as it is only dependent on current and electrical resistivity of the material. The AgNi has a slightly higher resistivity than pure Ag (around 14%) thus τ p has a higher value. Because of different thermal conductivity λ of the two materials the temperature rise τ z and Δτ of AgNi is slightly smaller that Ag. The greatest influence on the temperature rise comes from the change in electrical contact resistance R z. Higher the contact spot resistance the real contact area gets smaller, which leads to higher current density and greater generation of heat. With the rise of the resistance by a factor of 3,81 the maximum temperature for the Ag and AgNi rose by 3,67 and 3,44 respectively. The additional temperature rise factor is even greater and is equal to 12,83 and 12,88 respectively. However use of AgNi as a contact material gave a slightly lower maximum temperature than Ag which is a better result as the contact spot shouldn t generate too much heat. In both cases with the higher contact resistance the additional temperature rise exceeded the maximum proposed rise of 20 K mentioned earlier. This may be the result of a higher that required contact resistance and by the imperfection of the theoretical model. The maximum temperature is not the only criteria based on which a material is chosen, amongst those criteria are the resistance against welding and electric wear.

140 Andrzej Książkiewicz, Ryszard Batura 3. ELECTRODYNAMIC CHARACTERISTIC OF ELECTRICAL CONTACT 3.1. Electrodynamic simplified theoretical model Reduction of the electrical contact cross area generates an electrodynamic force F y which is repealing the contacts apart [3]: μ 0 2 ln r1 F y = i (5) 4π r2 where: r 1 radius of cylindrical contact, r 2 real contact area radius. A simplified model representing the two radius values is presented on figure 2. Fig. 2. Simplified model of single point electric contact [1] To calculate this force the radius r 2 has to be known. It is almost impossible to determinate its value, and for single contact point only an approximation can be made based on the contact closing force and contact material properties and is described by [3]: Fs r2 = (6) πσ where: F s contact closing force, σ 0 yield strength of contact material. Another way to determinate the real contact radius can be based on electric contact resistance and the elliptical contact surface model [4]: ρ R = (7) 2r 2 With known contact resistance and the resistivity of contact material the value of r 2 can be calculated. 0

Thermal and electrodynamic characteristics of electrical contact... 141 3.2. Results of electrodynamic characteristics calculations Based on equation 5 electrodynamic force was calculated for to contact resistances 2 mω (Fig. 3) and 7 mω (Fig. 4). F [N] 1,6 1,4 1,2 1 0,8 0,6 0,4 0,2 0 0 20 40 60 80 100 120 140 160 180 200 i [A] Fy F Fig. 3. Repelling contact force F y dependent on current (R = 2 mω), F relay nominal contact force 1,4 1,2 1 F [N] 0,8 0,6 0,4 0,2 0 0 10 20 30 40 50 60 70 80 90 100 i [A] Fy F Fig. 4. Repelling contact force F y dependent on current (R = 7 mω), F relay nominal contact force As mentioned earlier the contact resistance determinates real contact area radius r 2. Greater electrical contact resistance leads to smaller contact spot area. That strengthens the effect generated by higher current density in the contact spot, which

142 Andrzej Książkiewicz, Ryszard Batura results in greater repelling force acting on the contacts. Relay nominal contact force was measured and it was not greater than 0,6 N. The calculated repelling force for both cases in the steady state is insignificant. However in case of a short circuit current there exists theoretical possibility that the contacts could open if the current value will be greater than 120 A and 60 A respectively. 4. CONCLUSION Influence of electric contact material on thermal and electrodynamic characteristics of electrical contact was discussed. Based on the results presented concerning temperature rise on contact spot a minimal influence of contact material can be observed. A much greater influence on thermal characteristics had electric contact resistance. The same relationship was found concerning the electrodynamic force. Higher value of contact resistance leads to lower tolerance for force generated by a greater current value but in relation to steady state its impact can be omitted. REFERENCES [1] Markiewicz H., Urządzenia elektroenergetyczne, WNT, Warszawa, 2006 (in Polish). [2] http://www.gljg.com.cn/en/lvc_sn.html [3] Au A., Maksymiuk J., Pochanke Z., Podstawy obliczeń aparatów elektroenergetycznych, WNT, Warszawa, 1976 (in Polish). [4] Ciok Z., Procesy łączeniowe w ukłądach elektroenergetycznych, WNT, Warszawa, 1983 (in Polish). [5] A. Książkiewicz: Change of electric contact resistance of an electromagnetic relay during switching operations without electric load, 5th International Interdisciplinary Technical Conference of Young Scientists, 16-18 May 2012, p. 257-260, Poznan.