Metadata, citation and similar papers at core.ac.uk

Similar documents
Detection of Estrogens in Aqueous and Solid Environmental Matrices by Direct Injection LC-MS/MS

Pesticide Analysis by Mass Spectrometry

LC-MS/MS Method for the Determination of Docetaxel in Human Serum for Clinical Research

Overview. Triple quadrupole (MS/MS) systems provide in comparison to single quadrupole (MS) systems: Introduction

Fast, Reproducible LC-MS/MS Analysis of Dextromethorphan and Dextrorphan

Analysis of the Vitamin B Complex in Infant Formula Samples by LC-MS/MS

Selective Testosterone Analysis in Human Serum by LC-FAIMS-MS/MS

CONFIRMATION OF ZOLPIDEM BY LIQUID CHROMATOGRAPHY MASS SPECTROMETRY

# LCMS-35 esquire series. Application of LC/APCI Ion Trap Tandem Mass Spectrometry for the Multiresidue Analysis of Pesticides in Water

UHPLC/MS: An Efficient Tool for Determination of Illicit Drugs

GENERAL UNKNOWN SCREENING FOR DRUGS IN BIOLOGICAL SAMPLES BY LC/MS Luc Humbert1, Michel Lhermitte 1, Frederic Grisel 2 1

Electrospray Ion Trap Mass Spectrometry. Introduction

ApplicationNOTE Introduction

AMD Analysis & Technology AG

Analysis of Free Bromate Ions in Tap Water using an ACQUITY UPLC BEH Amide Column

UPLC-MS/MS Analysis of Aldosterone in Plasma for Clinical Research

Jennifer L. Simeone and Paul D. Rainville Waters Corporation, Milford, MA, USA A P P L I C AT ION B E N E F I T S INT RO DU C T ION

How To Test For Contamination In Large Volume Water

Simultaneous qualitative and quantitative analysis using the Agilent 6540 Accurate-Mass Q-TOF

SPE, LC-MS/MS Method for the Determination of Ethinyl Estradiol from Human Plasma

Online SPE-LC-APCI-MS/MS for the Determination of Steroidal Hormones in Drinking Water

Quantitative analysis of anabolic steroids in control samples from food-producing animals using a column-switching LC-HESI-MS/MS assay

Determination of Anabolic Steroids in Horse Urine by SPE and LC-MS/MS

Using Natural Products Application Solution with UNIFI for the Identification of Chemical Ingredients of Green Tea Extract

Biocides main groups

Extraction of Cannabinoids in Marijuana and Edibles by QuEChERS

Application Note. Determination of Nitrite and Nitrate in Fruit Juices by UV Detection. Summary. Introduction. Experimental Sample Preparation

Chemistry 321, Experiment 8: Quantitation of caffeine from a beverage using gas chromatography

Extraction of Epinephrine, Norepinephrine and Dopamine from Human Plasma Using EVOLUTE EXPRESS WCX Prior to LC-MS/MS Analysis

Separation of Amino Acids by Paper Chromatography

Guide to Reverse Phase SpinColumns Chromatography for Sample Prep

Application of Structure-Based LC/MS Database Management for Forensic Analysis

LC-MS/MS for Chromatographers

Simultaneous Metabolite Identification and Quantitation with UV Data Integration Using LightSight Software Version 2.2

A feasibility study of the determination of B-group vitamins in food by HPLC with Mass Spectrometric detection. LGC/R/2011/181 LGC Limited 2011

Discovery of Pesticide Protomers Using Routine Ion Mobility Screening

Bruker ToxScreener TM. Innovation with Integrity. A Comprehensive Screening Solution for Forensic Toxicology UHR-TOF MS

A High Throughput Automated Sample Preparation and Analysis Workflow for Comprehensive Forensic Toxicology Screening using LC/MS/MS

Supplementary Materials and Methods (Metabolomics analysis)

Metabolomic Profiling of Accurate Mass LC-MS/MS Data to Identify Unexpected Environmental Pollutants

Micromass LCT User s Guide

DEVELOPMENT OF PFCs HIGH SENSITIVITY ANALYSIS METHOD APPLIED RETENTION GAP TECHNIQUE WITH UPLC/MS/MS

Accurate Mass Screening Workflows for the Analysis of Novel Psychoactive Substances

The Use of Micro Flow LC Coupled to MS/MS in Veterinary Drug Residue Analysis

Appendix 5 Overview of requirements in English

Eleanor Riches Waters Corporation, Manchester, UK INTRODUCTION

Overview. Purpose. Methods. Results

Extraction, Derivatization and Ultra-Sensitive GC/Triple Quadrupole Analysis of Estrone and Estradiol in Human Serum

Analysis of Polyphenols in Fruit Juices Using ACQUITY UPLC H-Class with UV and MS Detection

Overview. Introduction. AB SCIEX MPX -2 High Throughput TripleTOF 4600 LC/MS/MS System

Name Lab #3: Solubility of Organic Compounds Objectives: Introduction: soluble insoluble partially soluble miscible immiscible

Mass Spectrometry. Overview

Quantitative Analysis of Explosives in Surface Water Comparing Off-Line Solid Phase Extraction and Direct Injection LC/MS/MS

Signal, Noise, and Detection Limits in Mass Spectrometry

PosterREPRINT AN LC/MS ORTHOGONAL TOF (TIME OF FLIGHT) MASS SPECTROMETER WITH INCREASED TRANSMISSION, RESOLUTION, AND DYNAMIC RANGE OVERVIEW

High-Throughput 3-D Chromatography Through Ion Exchange SPE

The Scheduled MRM Algorithm Enables Intelligent Use of Retention Time During Multiple Reaction Monitoring

MS/MS analysis of Polyphenols

HRMS in Clinical Research: from Targeted Quantification to Metabolomics

Sample Analysis Design Isotope Dilution

13C NMR Spectroscopy

GUIDELINES ON THE USE OF MASS SPECTROMETRY (MS) FOR IDENTIFICATION, CONFIRMATION AND QUANTITATIVE DETERMINATION OF RESIDUES CAC/GL

Analysis of Pesticides in Vegetables Using the Agilent 1260 Infinity Analytical SFC System with Triple Quadrupole MS Detection

Develop a Quantitative Analytical Method for low (» 1 ppm) levels of Sulfate

Oasis HLB Cartridges and 96-Well Plates

Thermo Scientific Prelude SPLC System FPO. Making LC/MS accessible. to clinical research and toxicology labs

Chapter 5 Classification of Organic Compounds by Solubility

Determination of Haloacetic Acids and Dalapon in Drinking Water by SPE and GC/ECD*

S olid Ph ase Extraction (SP E) Method:

Intelligent use of Relative Response Factors in Gas Chromatography-Flame Ionisation Detection

Analysis of Organophosphorus Pesticides in Milk Using SPME and GC-MS/MS. No. GCMS No. SSI-GCMS Shilpi Chopra, Ph.D.

Daniel M. Mueller, Katharina M. Rentsch Institut für Klinische Chemie, Universitätsspital Zürich, CH-8091 Zürich, Schweiz

Fast and Accurate Analysis of Vitamin D Metabolites Using Novel Chromatographic Selectivity and Sample Preparation

NANOCOMPOSIX'S GUIDE TO ICP-MS MEASUREMENT

Analyzing Small Molecules by EI and GC-MS. July 2014

Opiates in Urine by SAMHSA GC/MS

Expectations for GC-MS Lab

Anion chromatography using on-line recycled eluents

Thermo Scientific SOLAµ SPE Plates Technical Guide. Consistent excellence. for bioanalysis

Ádám Tölgyesi Joerg Stroka. Report EUR EN

Thermo Scientific HyperSep Solid Phase Extraction Method Development Guide

Cliquid Drug Screen & Quant Software for Routine Forensic Toxicology. great interest in forensic, toxicological and clinical research laboratories.

Unique Software Tools to Enable Quick Screening and Identification of Residues and Contaminants in Food Samples using Accurate Mass LC-MS/MS

Project 5: Scoville Heat Value of Foods HPLC Analysis of Capsaicinoids

Environmental Water Testing: Surface Water, Groundwater, Hard Water, Wastewater, & Seawater

Step-by-Step Analytical Methods Validation and Protocol in the Quality System Compliance Industry

A VISION to On-Line SPE PTV GC MS Determination of Organic Micro Pollutants in Surface Water

New drugs of abuse? A case study on Phenazepam & Methoxetamine

Determination of Pesticide Residues in Drinking Water Using Automated Solid-Phase Extraction and Gas Chromatography with Nitrogen Phosphorus Detection

Determination of Tricyclazole in Water Using Solid Phase Extraction and Liquid Chromatography

ACID-BASE TITRATIONS: DETERMINATION OF CARBONATE BY TITRATION WITH HYDROCHLORIC ACID BACKGROUND

The Automated SPE Assay of Fipronil and Its Metabolites from Bee Pollen.

CORESTA RECOMMENDED METHOD N 72

Determination of Calcium and Magnesium in Brine

Separation by Solvent Extraction

Enhancing GCMS analysis of trace compounds using a new dynamic baseline compensation algorithm to reduce background interference

Transcription:

CORE Provided by Digital.CSIC Metadata, citation and similar papers at core.ac.uk Low Nanogram Per Liter Determination of Halogenated Nonylphenols, Nonylphenol Carboxylates, and Their Non-Halogenated Precursors in Water and Sludge by Liquid Chromatography Electrospray Tandem Mass Spectrometry M. Petrovic and D. Barceló Department of Environmental Chemistry, IIQAB-CSIC, Barcelona, Spain A. Diaz and F. Ventura AGBAR, Barcelona, Spain A new LC-MS-MS method for quantitative analysis of nonylphenol (NP), nonylphenol carboxylates (NPECs), and their halogenated derivatives: brominated and chlorinated nonylphenols (BrNP, ClNP), brominated and chlorinated nonylphenol carboxylates (BrNPE 1 C and ClNPE 1 C) and ethoxycarboxylates (BrNPE 2 C and ClNPE 2 C) in water and sludge has been developed. Electrospray negative ionization MS-MS was applied for the identification of above mentioned compounds. Upon collision-induced dissociation, their deprotonated molecules gave different fragments formed by the cleavage of the alkyl moiety and/or (ethoxy)carboxylic moiety. For halogenated compounds a highly diagnostic characteristic pattern of isotopic doublet signals was obtained and fragmentation yielded, in addition to above mentioned ions, [Br] and [Cl], respectively. Quantitative analysis was done in the multiple reaction monitoring (MRM) mode, using two specific combinations of a precursor-product ion transitions for each compound. Additionally, for halogenated compounds two specific channels for each transition reaction, corresponding to two isotopes, were monitored and the ratio of their abundances used as an identification criterion. The method has been validated in terms of sensitivity, selectivity, accuracy, and precision and was applied to the analysis of water and sludge samples from drinking water treatment plant (DWTP) of Barcelona (Catalonia, NE Spain). Halogenated NP and NPECs were detected in prechlorinated water in concentrations up to 315 ng/l, BrNPE 2 C being the most abundant compound. In the DWTP effluent non-halogenated compounds were detected at trace levels (85, 12 and 10 ng/l for NP, NPE 1 C, and NPE 2 C, respectively), whereas concentration of halogenated derivatives never exceeded 10 ng/l. Nonylphenol, brominated and chlorinated NPs were found in flocculation sludge in concentrations of 150, 105, and 145 g/kg, respectively. Acidic polar metabolites were found in lower concentrations up to 20 g/kg. (J Am Soc Mass Spectrom 2003, 14, 516 527) 2003 American Society for Mass Spectrometry Published online April 2, 2003 Address reprint requests to Dr. M. Petrovic, Department of Environmental Chemistry, IIQAB-CSIC, c/jordi Girona 18-26, 08034 Barcelona, Spain. E-mail: mpeqam@cid.csic.es Non-ionic surfactants, nonylphenol polyethoxylates (NPEOs), have been widely used in the last 40 years as detergents, emulsifiers, dispersants, antifoamers and pesticide adjuvants. The biodegradation of NPEOs under aerobic conditions yields mainly short ethoxy chain oligomers (NPEO 1 and NPEO 2 ), whereas under anaerobic conditions fully deethoxylated nonylphenol (NP) is also formed. Further transformation leads to acidic metabolites formed by oxidation of the ethoxy chain (nonylphenol carboxylates; NPECs) as well as oxidation of the branched alkyl chain [1 4]. During the chlorination process at drinking water treatment plants (DWTP) [5 8] and wastewater treatment plants (WWTP) [9, 10] the formation of halogenated derivatives, such as ring-brominated and chlorinated NPEOs, NPECs, and NPs, have been reported. Toxicity of NP and short ethoxy chain NPEOs to aquatic organisms [11], lipophilic properties that lead to bioaccumulation in aquatic food chain [12], and ability 2003 American Society for Mass Spectrometry. Published by Elsevier Science Inc. Received December 6, 2002 1044-0305/03/$30.00 Revised January 27, 2003 doi:10.1016/s1044-0305(03)00139-9 Accepted February 12, 2003

J Am Soc Mass Spectrom 2003, 14, 516 527 NONYLPHENOL CARBOXYLATES IN WATER AND SLUDGE 517 to mimic endogenous hormone 17 -estradiol [13, 14] are well documented. However, little is known about environmental significance and toxicology of brominated and chlorinated alkylphenolic compounds. Maki et al. [15] determined that, both BrNPEOs and BrN- PECs, show higher acute toxicity to Daphnia magna than their non-brominated precursors NPEOs and NPECs. A recent study, employing recombinant yeast assay (RYA) and enzyme linked receptor assay (ELRA) for the determination of estrogenic and anti-estrogenic activity, showed that halogenated compounds retained a significant affinity for the estrogen receptors suggesting that they may be still able to disturb the hormone imbalance of exposed organisms [16]. This was especially clear for halogenated NPECs, which acted as true anti-estrogens in the RYA. The presence of alkylphenolic compounds in the environment has become of increasing concern globally and efforts have been made to determine their concentration levels in WWTP and in aquatic environments. However, studies to date have largely focused on short chain NPEOs, NPECs, and NPs, while fewer reports have included halogenated metabolites. One of the reasons for this is the low relative abundance of these compounds (generally less than 10% of the total pool of alkylphenolic compounds) and unavailability of appropriate analytical methods for their identification and quantification. The first attempts to analyse halogenated alkylphenolic compounds were carried out using Fast Atom Bombardment-Mass Spectrometry (FAB-MS) [5, 7, 8, 17], which proved to be a reliable tool for the identification of halogenated metabolites in raw and drinking water, but not for their quantification. Recently, some efforts have been made to quantify these compounds in complex environmental and wastewater samples. Methods applied included gas chromatography-mass spectrometry (GC-MS) [10, 18, 19] (after appropriate derivatization) and reversed-phase liquid chromatography with electrospray mass spectrometry (LC-ESI-MS) [6, 20, 21]. ESI permitted the direct determination of the full range of halogenated NPEOs metabolites (i.e., XN- PEOs, XNPECs and XNPs), as well as their precursors in aqueous and solid samples, thus obviating the necessity to methylate them. However, using soft ionization LC-MS, under conditions giving solely molecular ions, the identification of halogenated compounds is difficult since the chlorinated derivatives (ClNPEO n and ClNPE n C) have the same molecular mass as brominated compounds with one ethoxy group less (BrN- PEO n-1 and BrNPE n-1 C) [6]. Moreover, in the analysis of real-world samples ClNPE 1 C was obstructed by a severe isobaric interference of linear alkylbenzene sulfonate (C 11 LAS), which is often found in environmental and wastewater samples in concentrations several orders of magnitude higher than those of halogenated alkylphenolic compounds. Thus, to obviate the matrix interference and interference of known and unknown compounds that may cause deviations when only a single stage of mass selectivity is used, more selective methods, such as tandem mass spectrometry are needed. However, although considered as one of the most powerful techniques for structure interpretation and quantification, LC-MS-MS has been seldom used in the analysis of acidic and neutral metabolites of NPEOs [2, 22], and has not been applied thus far to study their halogenated derivatives. In the present work, a tandem mass spectrometric investigation of halogenated NPECs, NPs and their precursors (non-halogenated analogs) was carried out. Electrospray negative ionization MS-MS was applied for the identification of acidic and neutral NPEOs metabolites. From the observed ion fragmentation pathways a reliable and sensitive quantification method, that overcomes the main drawbacks on existing methods, is developed. The method was applied to study occurrence of halogenated alkylphenolic compounds derived from chlorination treatment in DWTP of Barcelona (Spain). To our knowledge this is the first LC- MS-MS method that permits analysis of halogenated NPs and NPECs at low nanogram per liter level. Experimental Standards and Reagents NPE 1 C and NPE 2 C were synthesized according to the method described elsewhere [19]. Technical grade 4-NP and 4-nonyloxy benzoic acid, used as an internal standard was obtained from Aldrich (Milwaukee, WI). BrNP was synthesized using elemental bromine according to the method described by Reinhard et al. [9]. ClNP was prepared by chlorination of nonylphenol using sulfuryl chloride according to the method of Stokker et al. [23]. BrNPE 1 C and ClNPE 1 C were synthesized by reacting brominated and chlorinated NP, respectively, with chloroacetic acid in the presence of sodium hydride and dimethylformamide as a solvent. These two synthesized compounds rendered BrNPEO 1 and ClNPEO 1 by reduction with lithium aluminum hydride in ether solution. BrNPEO 2 and ClNPEO 2 were synthesized by reacting BrNP and ClNP, respectively, with 2-(2-chloroethoxy)ethanol in the presence of NaOH in water. Finally, BrNPE 2 C and ClNPE 2 C were obtained from BrNPEO 2 and ClNPEO 2, respectively, by oxidation with Jones reagent [9]. Water Samples Raw water entering the DWTP Sant Joan Despí (Barcelona, Spain) and water samples after each treatment step (i.e., prechlorination, rapid sand filtration, groundwater dilution, ozonation, granulated active carbon filtration, and final chlorination) were collected as grab samples in Pyrex borosilicate amber glass containers, previously rinsed with high-purity water. NP, NPECs, and their halogenated derivatives were

518 PETROVIC ET AL. J Am Soc Mass Spectrom 2003, 14, 516 527 Table 1. List of MRM channels, cone and collision energies applied to ESI-MS-MS for the analysis of nonylphenol, nonylphenol carboxylates, and their halogenated derivatives MRM 1 (Quantification) MRM 2 (Confirmation) Compound Precursor (m/z) 3 Product (m/z) Cone (V) Collision (ev) Precursor (m/z) 3 Product (m/z) Cone (V) Collision (ev) Ratio MRM1/ MRM2 NP 219 3 133 30 30 219 3 147 30 30 9.2 BrNP 297 3 79 30 30 297 3 211 30 30 12.3 299 3 81 299 3 213 CINP 253 3 167 30 30 253 3 181 30 30 10.5 255 3 169 255 3 183 NPE 1 C 277 3 219 10 30 219 3 133 30 30 1.8 BrNPE 1 C 355 3 297 10 30 355 3 79 30 30 1.0 357 3 299 357 3 81 ClNPE 1 C 311 3 253 10 30 253 3 167 30 30 3.5 313 3 255 255 3 169 NPE 2 C 219 3 133 30 30 321 3 219 10 30 1.2 BrNPE 2 C 297 3 79 30 30 399 3 297 5 20 2.0 299 3 81 401 3 299 ClNPE 2 C 253 3 167 30 30 355 3 253 5 20 5.5 255 3 169 357 3 255 isolated from water samples using solid-phase extraction (SPE). A more detailed description of the SPE method is given elsewhere [6]. Briefly, 500 ml of water samples were loaded onto preconditioned Accubond C18 cartridges (J and W Scientific, Folsom, CA). Cartridges were air-dried under vacuum, and were eluted with 2 4 ml of methanol. The eluates were taken gently to dryness under a nitrogen steam and reconstituted in 500 L of methanol. Sludge Samples Sludge from DWTP of Barcelona, obtained from prechlorinated raw water after flocculation with aluminium sulfate and mixed in a minor proportion with sludge coming from the washing of sand filters, was collected in precleaned amber glass bottles. The suspension (concentration of dry matter 3.5 to 5 g/l) was centrifuged at 4500 rpm, and the solid matter was separated and frozen at 20 C before being freezedried. Pressurized liquid extractions (PLE) were carried out using a Dionex ASE 200 (Dionex, Idstein, Germany) as described elsewhere [24]. Briefly, 1 g sub-sample of freeze-dried sludge was mixed with Na 2 SO 4 and filled into 11 ml extraction cells. Extraction was carried out with acetone/methanol (1:1, vol/vol) under following conditions: temperature of 75 C, pressure 1500 psi, heating time 5 min, two cycles of static extraction (5 min). As a final step, the cell was purged with gaseous nitrogen. The total volume of extract was 20 ml. Extracts obtained by PLE, were concentrated to an approximate volume of 1 ml using a rotary vacuum, redissolved in 100 ml of HPLC water and subsequently purified by SPE using LiChrolute C18 cartridges (Merck, Darmstadt, Germany), as described elsewhere [6]. Chromatographic Conditions Analyses were performed on a Waters 2690 series Alliance HPLC (Waters, Milford, MA) with a quaternary pump equipped with a 120 vial capacity sample management system. The analytes were separated on a narrow-bore 3 m, 55 2 mm i.d. C 18 reversed phase column Purospher STAR RP-18 endcapped (Merck, Darmstadt, Germany). The sample injection volume was set at 10 L. A binary mobile phase gradient with methanol (A) and water (B) was used for analyte separation at a flow rate of 200 L/min. The elution gradient was linearly increased from 30% A to 85% A in 10 min, then increased to 95% A in 10 min and kept isocratic for 5 min. Figure 1. Product ion scan of NP with m/z 219 and the proposed fragmentation scheme under CID conditions obtained using argon as collision gas at collision energy of 40 ev. Note: The exact branching of the alkyl chain is unknown and the alkyl isomer shown here is just one of several possibilities.

J Am Soc Mass Spectrom 2003, 14, 516 527 NONYLPHENOL CARBOXYLATES IN WATER AND SLUDGE 519 Figure 2. MS/MS chromatograms of raw effluent (river water) treated in Barcelona drinking water treatment plant corresponding to nonylphenolic compounds (MRM mode: 219 3 133 and 219 3 147 for detection of NP, NPE 1 C, and NPE 2 C; 277 3 219 for NP 1 EC and 321 3 219 for NP 2 EC). Mass Spectrometry A bench-top triple quadrupole mass spectrometer Quattro LC from Micromass (Manchester, UK) equipped with a pneumatically assisted electrospray probe and a Z-spray interface was used for this study. Capillary voltage was set at 2.8 kv, extractor lens 7 V and RF lens 0.6 V. The source and desolvation temperatures were 150 and 350 C, respectively. The nitrogen (99.999% purity) flows were optimized at 50 L/h for the cone gas and 540 L/h for desolvation gas. For each analyte the values of the voltages applied to the cone, focusing lenses, collision cell, and quadrupoles were optimized by continuous infusion of a standard solution (1 g/ml) via a syringe infusion pump Kd Scientific 100 (Boston, MA) at a constant flow-rate of 20 L/min. All ESI mass spectral data were acquired with Masslynx NI software (version 3.5). MS scans. For one stage MS scans the cone voltage was varied from 10 to 50 V according to the type of experiment performed and analyte studied. Full-scan mass spectra were recorded between m/z 30 and 500, with scan duration of 1 s/scan and an interscan time of 0.1 s. MS/MS scans. The cone voltage was set to a value, which resulted in maximum abundance of the pseudo molecular ion (see Table 1). The argon collision gas was maintained at a pressure of 5.8 10 3 mbar. The optimum collision energy was chosen after performing MS/MS product ion scans on [M H] over a range of energies between 10 and 50 ev. The electron multiplier was set at 600 V. For experiments performed in MRM mode scan time was 1 s/scan, and the dwell time ranged from 50 to 200 ms, depending on the number of transition channels monitored (from 10 to 20). Quantification Quantitative analyses were done in MRM mode. The extent of ion suppression of MS signal was determined using 4-nonyloxy benzoic acid as an internal standard. The results (see Discussion) showed very limited signal reduction (less than 15% for sludge and negligible for water samples), thus the quantification was performed using external calibration. Initially, a series of injections of target compounds in the concentration range from 1 ng/ml to 10 g/ml was used to determine the linear concentration range. Calibration curves were generated using linear regres-

520 PETROVIC ET AL. J Am Soc Mass Spectrom 2003, 14, 516 527 Figure 3. CID spectra and the proposed fragmentation pattern of (a) ClNP (precursor ions m/z 253 and 255) and (b) BrNP (precursor ions m/z 297 and 299) obtained at collision energy of 30 ev. Note: The exact branching of the alkyl chain is unknown and the alkyl isomer shown here is just one of several possibilities. sion analysis and over the established concentration range (0.01 1 g/ml) gave good fits (r 2 0.990). Five-point calibration was performed daily, and the possible fluctuation in signal intensity was checked by injecting a standard solution at two concentration levels after each 8 10 injections. Results and Discussion Mass Spectrometry Optimization of Experimental Conditions A preliminary study was carried out using the single quadrupole mode under full-scan conditions and the negative ionization. The cone voltage was adjusted to give the maximum abundance of deprotonated molecule [M H], which were chosen as precursor ions in further MS-MS experiments, performed with the purpose of finding the best instrumental conditions for the identification of target compounds. NP and NPECs. The product ion scan of [M H] for NP evidenced fragmentation of the side chain of deprotonated molecule (Figure 1), resulting in sequential loss of CH 2 groups (m/z 14), down to specie with m/z 93. The most abundant fragments with m/z 133 and 147 resulted from the loss of C 6 H 14 and C 5 H 12, respectively. The product ion spectra of deprotonated molecule at m/z 277 (for NPE 1 C) and m/z 321 (for NPE 2 C), showed the intense signal at m/z 219, corresponding to [M CH 2 COO H] and [M CH 2 CH 2 OCH 2 COO H], respectively, as reported previously by other authors [2, 22]. Additional fragments at m/z 133 and 147 were formed by the fragmentation on the side chain, as described above for NP. Thus, specific transitions at m/z 277 3 219 and m/z 321 3 219 could be used to monitor NPE 1 C and NPE 2 C, respectively, while MRM channels at m/z 219 3 133 and m/z 219 3 147 are characteristic for both NP and NPECs, and could be used to monitor all these compounds: However, in the latter case good chromatographic separation is essential, as depicted in Figure 2. Halogenated NP and NPECs. Owing to the presence of chlorine and bromine atoms in the molecules, halogenated derivatives yielded a characteristic pattern of isotopic doublet signals, which was a highly diagnostic fingerprint for this group of compounds. The main fragmentation process of ClNP was similar to those observed for NP. The predominant reaction was the side chain fragmentation that resulted in sequential loss of 14 Da, with the most abundant fragments at m/z 167 for 35 Cl and m/z 169 for 37 Cl with the

J Am Soc Mass Spectrom 2003, 14, 516 527 NONYLPHENOL CARBOXYLATES IN WATER AND SLUDGE 521 Figure 4. CID spectra and the proposed fragmentation pattern of (a) ClNPE 1 C (precursor ions m/z 311 and 313) and (b) BrNPE 1 C (precursor ions m/z 355 and 357) obtained at collision energy of 30 ev. Note: The exact branching of the alkyl chain is unknown and the alkyl isomer shown here is just one of several possibilities. relative ratio of intensities of 3.03 (Figure 3a). Fragment corresponding to [Cl] was produced only when sufficient collision energy was applied. The intensity of this ion was not very pronounced, but nevertheless remained useful for the identification of chlorinated NP. The brominated NP showed a markedly different fragmentation pathway (Figure 3b). At collision energy of 40 ev the product ion spectra of BrNP (m/z 297/299) yielded intense signals at m/z 79 and 81 corresponding to the [Br] (ratio of isotopes 1.02), while the fragmentation of the side chain was suppressed and resulted just in a low-intensity fragment at m/z 211/213 produced after the loss of C 6 H 14. For halogenated NPE 1 Cs and NPE 2 Cs (Figure 4) the predominant reaction was loss of CH 2 COO and CH 2 CH 2 OCH 2 COO, respectively, that resulted in intense signals at m/z 253/255 for ClNPECs and m/z 297/299 for BrNPECs. Further fragmentation yielded the same ions as described above for halogenated NPs, i.e., [ 79 Br] and [ 81 Br] for brominated NPECs and m/z 167/169 and m/z 181/183 for ClNPECs. Such difference in the mechanism of fragmentation of chlorinated and brominated compounds is presumably the consequence of the lower energy of a Br C 6 H 5 (benzene) bond compared to a Cl C 6 H 5 bond. BrNPECs yielded [Br] at low collision energies (10 ev), as shown in Figure 5a for BrNPE 2 C, while ClNPECs produced [Cl] only at higher collision energy (50 ev) (Figure 5f). At collision energy of 50 ev the m/z 79/81 ion was the sole fragment ion observed for BrNPE 2 C, while chlorinated analog showed, in addition to m/z 167/169, fragments at m/z 131 and m/z 145. These two fragments, observed as product ions of both 35 ClNPE 2 C and 37 ClNPE 2 C, respectively, did not show characteristic isotopic pattern and were tentatively assigned as fragments formed by the cleavage of ethoxycarboxylated moiety, chlorine and by the cleavages in the alkyl moiety. From the observed fragmentation pathways the dominant dissociation reaction channels were chosen (Table 1). The cone voltage of each transition was optimized to a value that gave the maximum abundance of the precursor ion, whereas the collision energy was set to a value that resulted in the maximal intensity of the product ion. Generally, deprotonated molecules where chosen as precursor ions, with the exception of NPE 2 C and halogenated NPE 2 Cs. Even at low cone voltages (5 10 V), in-source CID was obtained for these compounds and their spectra displayed low abundance of deprotonated molecules. Thus, for these compounds the most intense MRM channels were those monitoring the fragmentation of the first generation products (e.g., 219 3 133 for NPE 2 C, 297/299 3 79/81 for BrNPE 2 C, and 253/255 3 167/169 for ClNPE 2 C).

522 PETROVIC ET AL. J Am Soc Mass Spectrom 2003, 14, 516 527 Figure 5. Product ion scans of XNPE 2 C obtained at 10, 30, and 50 ev: (a), (c), and (e) 79 BrNPE 2 C (precursor ion m/z 399); (b), (d), and (f) 35 ClNPE 2 C (precursor ion m/z 355). Positive identification criterion of the target compounds was based on: (1) LC retention time of the analyte compared to that of a standard ( 2%), (2) the ratio of abundances of two specific precursor ion 3 product ion transitions (within 10% of the ratios obtained for the standard). Additionally, for halogenated compounds a highly diagnostic criteria was the abundance ratio of characteristic isotopes ( 79 Br: 81 Br 1.02; 35 Cl: 37 Cl 3.03) and for each transition reaction two specific channels, corresponding to two isotopes, were monitored and the ratio of their abundances calculated. High selectivity of the MS-MS detection of halogenated nonylphenolic compounds is shown in Figures 6 and 7, which display extracted MRM chromatograms for chlorinated and brominated compounds, respectively, detected in water and sludge samples from DWTP of Barcelona. A specificity of MRM mode permitted identification and quantification of halogenated NPECs, thus obviating isobaric interference of ClNPE 1 C and C 11 LAS (both having a base ion at m/z 311) observed using a LC-MS in selected ion monitoring (SIM) mode [6]. Note that broad and, in some cases multiple peaks, observed, e.g., for brominated compounds (Figure 7), reflect the multitude of isomers arising from the different branching of the nonyl entity and probably co-existence of different isomers of the benzene ring, i.e., 2-NP, which makes up to 10% of NP in industrial blends, and consequently different position of bromine and chlorine, respectively. Other MS-MS modes, such as the precursor ion scan and neutral loss scan, were found to be less useful MS/MS scanning modes as they were 5 to 10 times less

J Am Soc Mass Spectrom 2003, 14, 516 527 NONYLPHENOL CARBOXYLATES IN WATER AND SLUDGE 523 Figure 6. Detection of chlorinated nonylphenolic compounds in prechlorinated water [traces (a) and (b)] and flocculation sludge [traces (c) and (d)] from Barcelona drinking water treatment plant. (MRM mode: 253 3 167 and 255 3 169 for detection of 35 Cl and 37 Cl-nonylphenolic compounds, respectively). sensitive than product ion MS-MS. The precursor ion scan of the m/z 133 yielded the [M H] ions of the respective NP, NPE 1 C, and NPE 2 C, together with small isotopic peaks one to several mass units higher. However, an acceptable mass chromatographic response was only obtained for nonylphenolic compounds, when present at concentrations higher than 0.5 g/l. For less abundant halogenated compounds precursor ion scan of m/z 79/81 for brominated compounds and precursor ion scans of m/z 167/169 and 35/37 for chlorinated compounds were not applicable to realworld samples due to low sensitivity. Quantitative Analysis Matrix effect. One of the problems to be solved when analyzing trace organics in complex matrices by LC- MS-(MS) is suppression of the analyte signal caused by high concentration of matrix components. The use of an internal standard can compensate, over a limited retention time window, for signal irreproducibility and correct quantitative data. However, it cannot compensate for the overall sensitivity reduction. Another approach to cope with matrix effect and to avoid an erroneous quantitation is aimed at the reduction of matrix components prior to the LC-MS-(MS) analysis applying a selective extraction and improved sample clean-up. Although the later strategy is laborious, it is still the most direct mean to avoid the loss of sensitivity. Analytical procedure (SPE for water samples and PLE with SPE clean-up for sludge samples), applied in this work, yielded rather clean extracts that produced low background MS noise, as described in details elsewhere [24]. The extent of ion suppression was checked by adding an internal standard (4-nonyloxy benzoic acid) to all extracts and monitoring the transition reaction from m/z 263 [M H] to m/z 92 (retention time t R 14.7 min). In comparison to the signal

524 PETROVIC ET AL. J Am Soc Mass Spectrom 2003, 14, 516 527 Figure 7. Detection of brominated nonylphenolic compounds in prechlorinated water [traces (a) (d)] and flocculation sludge [traces (e) and (f)] from Barcelona drinking water treatment plant. MRM mode: (a) 357 3 299 and (b) 355 3 297 for BrNPE 1 C; (c) 401 3 299 and (d) 399 3 297 for BrNPE 2 C; (e) 297 3 79 and (f) 299 3 81 for BrNP. intensity obtained in a standard solution (methanol), the flocculation sludge was the only sample that showed a reduced value (limited to 10 to 15% of ion suppression for all analyzed samples), while less complicated matrices (river water and drinking water) showed negligible loss of sensitivity. Validation Parameters. Recoveries obtained using LC- MS-MS (MRM) were similar to those previously reported for LC-MS (SIM) [6, 24]. SPE of target analytes from water samples combined with LC-MS-MS detection yielded recoveries from 72 to 98% (see Table 2), whereas for solid samples PLE followed by SPE extract

J Am Soc Mass Spectrom 2003, 14, 516 527 NONYLPHENOL CARBOXYLATES IN WATER AND SLUDGE 525 Table 2. Instrumental detection limits (LOD inst ) of LC-MS and LC-MS-MS, method detection limits (LOD method ), and recoveries of combined SPE-LC-MS-MS for the analysis of target compounds in water samples and PLE-LC-MS-MS for solid samples LOD inst (pg injected) LOD method Recovery, % (RSD, n 3) Compound LC-MS (SIM) LC-MS-MS (MRM) Water samples (ng/l) a Sludge samples ( g/kg) b Water samples SPE-LC-MS- MS Sludge samples PLE-LC-MS-MS NP 60 10 1 0.5 85 (5) 81 (9) XNP 50 15 2 1.0 72 (7) CINP 60 (14) CINP 73 (7) BrNP 64 (11) BrNP NPE 1 C 100 30 2 1.5 98 (5) 78 (8) XNPE 1 C 150 50 2 1.5 90 (6) CINPE 1 C 71 (12) ClNPE 1 C 92 (7) BrNPE 1 C 75 (9) BrNPE 1 C NPE 2 C 100 30 2 1.5 88 (4) 68 (10) XNPE 2 C 200 50 2 1.5 84 (6) ClNPE 2 C 79 (7) BrNPE 2 C n.d. a SPE preconcentration factor 1000; 20 MRM channels (for other conditions see Experimental part). b PLE, preconcentration factor 2; 20 MRM channel. %n.d. not determined. clean-up and LC-MS-MS detection resulted in recoveries of 60 to 81% of target compounds. The relative standard deviation (n 3) for water analysis was below 7% and for sludge below 14%. Intra-day variability of calibration curve slopes was minimal ( 5%), while inter-day variability of daily calibration curve slopes over 1 week period ranged from 5 to 10% depending on the analyte. The comparison of instrumental detection limits (LOD inst ) obtained using LC-MS and LC-MS-MS in SIM and MRM mode, respectively, and method detection limits (LOD method ) (MRM mode) are shown in Table 2. The LODs were based on the peak-to-peak noise of the baseline near the analyte peak obtained by analyses of a standard solution (LOD inst ) and real-samples (LOD method ), respectively, and on minimal value of signal-to-noise ratio of 3. The method LODs refer to SPE-LC-MS-MS procedure for water samples, based on a preconcentration factor of 1000, and PLE-LC-MS-MS for sludge samples (preconcentration factor 2). Values of LOD inst obtained by LC-MS-MS were approximately 3 6 times lower than by LC-MS (SIM). The detection limits of the method proposed here for the analysis of target compounds in water samples fell down to 1 2 ng/l and in sludge samples ranged from 0.5 to 1.5 g/kg, which is significant improvement in comparison to LODs reported previously for GC-MS [18] and LC-MS [6]. Analysis of Real Samples The feasibility of LC-MS-MS method for the analysis of halogenated and non-halogenated NP and NPECs was evaluated by analyzing samples from DWTP Sant Joan Despí in Barcelona. The waterworks, with the daily production of 300,000 m 3 of drinking water, are situated at the Llobregat River downstream of a densely industrialized area. The whole river basin receives effluents from more than 30 WWTPs, which results in poor quality of the water entering to DWTP. Moreover, the specificity of the Llobregat River is a high concentration of bromide ions (average 0.7 mg/l, maximum 1.2 mg/l in 2000) [25] that arises from salt mine activities in the upper course of the river. As a consequence, it was already reported that treated (tap) water contains rather high concentration of brominated disinfection by-products [26]. NP and NPECs were found in the Llobregat River water entering the water treatment plant in concentrations of 1.5, 2.0, and 2.9 g/l for NP, NPE 1 C and the Table 3. Concentrations found DWTP (Barcelona, Spain) samples Concentration in water (ng/l) Compound Raw water Prechlorination Sand filter Ozonation Carbon filter Chlorination Flocculation sludge ( g/kg) NP 1500 240 220 250 160 92 150 NPE 1 C 2000 1640 1600 65 30 12 7.0 NPE 2 C 2900 1960 2200 76 35 10 20 BrNP n.d. 17 19 5 n.d. n.d. 105 ClNP n.d. 9 12 5 n.d. n.d. 145 BrNPE 1 C n.d. 120 130 57 21 5 n.d. ClNPE 1 C n.d. 14 19 13 5 5 n.d. BrNPE 2 C n.d. 316 353 217 52 10 13 ClNPE 2 C n.d. 45 60 26 5 5 7.5 n.d. - not detected

526 PETROVIC ET AL. J Am Soc Mass Spectrom 2003, 14, 516 527 most abundant NPE 2 C, respectively, whereas their halogenated analogs were not detected as expected (Table 3). The following treatment process consists of prechlorination, flocculation with aluminum sulfate, sand filtration, groundwater dilution, ozonation, granular activated carbon filtration and a final chlorination. During the prechlorination steps, NP and NPECs were found to transform to halogenated derivatives. Both, brominated and chlorinated NP and NPECs were detected in prechlorinated water in concentrations up to 315 ng/l, being BrNPE 2 C the most abundant specie. The main part of these compounds, as well as of their precursors were removed by ozonation and subsequent activated carbon filtration. After final chlorination, in the treated water leaving the DWTP non-halogenated compounds were detected at trace levels (85, 12, and 10 ng/l for NP, NPE 1 C, and NPE 2 C, respectively) indicating the efficient removal of these compounds (95% of NP and more than 99% of acidic metabolites). Halogenated derivatives were identified but their concentrations never exceeded 10 ng/l. The flocculation sludge (daily production 30,000 kg dry matter) was found to accumulate hydrophobic halogenated compounds and their precursors. NP, brominated and chlorinated NPs were found in concentrations of 150, 105, and 145 g/kg, respectively. Acidic, polar metabolites were found in concentrations up to 20 g/kg. Conclusions This work presents for the first time the application of liquid chromatography-tandem mass spectrometry to the analysis of halogenated nonylphenolic compounds and their precursors. MS-MS study of target compounds showed characteristic fragmentation pattern for each group of compounds that provided sufficient structural information and permitted the election of specific transition channels for their identification. In addition to the advantages related to the quantification in MRM mode (high sensitivity and selectivity) the method allowed determination of isobaric target compounds (e.g., BrNPE 1 C and ClNPE 2 C) and elimination of interference of co-eluting isobaric no-target compounds (e.g., C 11 LAS). The method yielded very low detection limits: low ng/l level in water samples and low g/kg level in sludge samples, thus providing a reliable and robust tool that can be used for routine analysis of estrogenic NP, NPECs, and their halogenated derivatives in aqueous and solid samples. Acknowledgments The work has been supported by the EU Project P-THREE (EVK1-CT-2002-00116) and by the Spanish Ministerio de Ciencia y Tecnologia (PPQ2002-10945-E). AD acknowledges a Ph.D. fellowship from Fundació Agbar. MP acknowledges the Ramon y Cajal contract from the Spanish Ministry of Science and Technology. The authors thank Merck for supplying the SPE cartridges and LC columns. References 1. Ahel, M.; Giger, W.; Koch, M. Behavior of Alkylphenol Polyethoxylate Surfactants in the Aquatic Environment. I. Occurrence and Transformation in Sewage Treatment. Water Res. 1994, 28, 1131 1142. 2. Jonkers, N.; Knepper, T. P.; de Voogt, P. Aerobic Biodegradation Studies of Nonylphenol Ethoxylates in River Water Using Liquid Chromatography-Electrospray Tandem Mass Spectrometry. Environ. Sci. Technol. 2001, 35, 335 340. 3. Di Corcia, A.; Constantino, A.; Crescenzi, C.; Marinoni, E.; Samperi, R. Characterization of Recalcitrant Intermediates from Biotransformation of the Branched Alkyl Side Chain of Nonylphenol Ethoxylate Surfactants. Environ. Sci. Technol. 1998, 32, 2401 2409. 4. Di Corcia, A.; Cavallo, R.; Crescenzi, C.; Nazzari, M. Occurrence and Abundance of Dicarboxylated Metabolites of Nonylphenol Polyethoxylate Surfactants in Treated Sewages. Environ. Sci. Technol. 2000, 34, 3914 3919. 5. Ventura, F.; Figueras, A.; Caixach, J.; Espadaler, I.; Romero, J.; Guardiola, J.; Rivera, J. Characterization of Polyethoxylated Surfactants and Their Brominated Derivatives Formed at the Water Treatment Plant of Barcelona by GC/MS and FAB Mass Spectrometry. Water Res. 1988, 22, 1211 1217. 6. Petrovic, M.; Diaz, A.; Ventura, F.; Barceló, D. Simultaneous Determination of Halogenated Derivatives of Alkylphenol Ethoxylates and Their Metabolites in Sludges, River Sediments, Surface, Drinking and Waste Waters by Liquid Chromatography-Mass Spectrometry. Anal. Chem. 2001, 73, 5886 5895. 7. Ventura, F.; Caixach, J.; Figueras, A.; Espadaler, I.; Fraisse, D.; Rivera, J. Identification of Surfactants in Water by Fast Atomic Bombardment Mass Spectrometry. Water Res. 1989, 23, 1191 1203. 8. Ventura, F.; Caixach, J.; Romero, J; Espadaler, I.; Rivera, J. New Methods for the Identification of Surfactants and Their Acidic Metabolites in Raw and Drinking Water: FAB MS and MS/ MS. Water Sci. Tech. 1992, 25, 257 264. 9. Reinhard, M.; Goodman, N.; Mortelmans, K. E. Occurrence of Brominated Alkylphenol Polyethoxy Carboxylates in Mutagenic Wastewater Concentrates. Environ. Sci. Technol. 1982, 16, 351 362. 10. Fujita, M.; Ike, M.; Mori, K.; Kaku, H.; Sakaguchi, Y.; Asano, M.; Maki, H.; Nishihara, T. Behavior of Nonylphenol Ethoxylates in Sewage Treatment Plants in Japan Biotransformation and Ecotoxicity. Water Sci. Technol. 2000, 42, 23 30. 11. Servos, M. R. Review of the Aquatic Toxicity, Estrogenic Responses, and Bioaccumulation of Alkylphenols and Alkylphenol Polyethoxylates. Water Qual. Res. J. Canada 1999, 34, 123 177. 12. Ahel, M.; Giger, W. Partitioning of Alkylphenols and Alkylphenol Polyethoxylates Between Water and Organic Solvents. Chemosphere 1993, 26, 1471 1478. 13. Jobling, S.; Sheahan, D.; Osborne, J. A.; Matthiessen, P.; Sumpter, J. P. Inhibition of Testicular Growth in Rainbow Trout (Oncorhynchus Mykiss) Exposed to Estrogenic Alkylphenolic Chemicals. Environ. Toxicol. Chem. 1996, 15, 194 202. 14. Jobling, S.; Sumpter, J. P. Detergent Components in Sewage Effluent are Weakly Estrogenic to Fish: An in Vitro Study Using Rainbow Trout (Oncorhynchus mykiss) hepatocytes. Aquat. Toxicol. 1993, 27, 361 372. 15. Maki, H.; Okamura, H.; Aoyama, I.; Fujita, M. Halogenation and Toxicity of the Biodegradation Products of a Nonionic

J Am Soc Mass Spectrom 2003, 14, 516 527 NONYLPHENOL CARBOXYLATES IN WATER AND SLUDGE 527 Surfactant, Nonylphenol Ethoxylates. Environ. Toxicol. Chem. 1998, 17, 650 654. 16. Requena, V., Petrovic, M., Garcia-Reyero, N., Barceló, D., Hansen, P. D., Piña, B. Estrogenic Potential of Halogenated Derivatives of Nonylphenol Ethoxylatyes and Carboxylates; unpublished. 17. Ventura, F.; Fraisse, D.; Caixach, J.; Rivera, J. Identification of [(Alkyloxy)poleythoxy] Carboxylates in Raw and Drinking Water by MS/MS and Mass Determination Using FAB and Nonionic Surfactant as Internal Standard. Anal. Chem. 1991, 63, 2095 2099. 18. Diaz, A.; Ventura, F.; Galceran, M. T. Development of a Solid-Phase Microextraction Method for the Determination of Short-Ethoxy-Chain Nonylphenols and Their Brominated Analogs in Raw and Treated Water. J. Chromatogr. A 2002, 963, 159 167. 19. Diaz, A.; Ventura, F.; Galceran, M. T. Simultaneous Determination of Estrogenic Short Ethoxy Chain Nonylphenols and Their Acidic Metabolites in Water by an In-Sample Derivatization/Solid Phase Microextraction Method. Anal. Chem. 2002, 74, 3869 3876. 20. Ferguson, P. L.; Iden, C. R.; Brownawell, B. J. Analysis of Alkylphenol Ethoxylate Metabolites in the Aquatic Environment Using Liquid Chromatography-Electrospray Mass Spectrometry. Anal. Chem. 2000, 72, 4322 4330. 21. Ferguson, P. L.; Iden, C. R.; Brownawell, B. J. Distribution and Fate of Neutral Alkylphenol Ethoxylate Metabolites in a Sewage-Impacted Urban Estuary. Environ. Sci. Technol. 2001, 35, 2428 2435. 22. Hao, C.; Croley, T. R.; March, R. E.; Koenig, B. G.; Metcalfe, C. D. Mass Spectrometric Study of Persistent Acid Metabolites of Nonylphenol Ethoxylate Surfactants. J. Mass Spectrom. 2000, 35, 818 830. 23. Stokker, G. E.; Daena, A. A.; Desolms, S. J.; Schultz, E. M.; Smith, R. L.; Cragoe, E. J.; Baer, J. E.; Ludden, C. T.; Russo, H. F.; Scriabine, A.; Sweet, C. S.; Watson, L. S. 2-(Aminomethyl)Phenols, a New Class of Saluretic Agents. J. Med. Chem. 1980, 23, 1414 1427. 24. Petrovic, M.; Lacorte, S.; Viana, P.; Barceló, D. Pressurized Liquid Extraction Followed by LC-MS for the Determination of Phenolic Xenoestrogens in River Sediment. J. Chromatogr. A. 2002, 959, 15 23. 25. AGBAR, Aigues de Barcelona, Internal Report. 2001. 26. Cancho, B.; Ventura, F.; Galceran, M. T. Behavior of Halogenated Disinfection By-Products in the Water Treatment Plant of Barcelona, Spain. Bull. Environ. Contam. Toxicol. 1999, 63, 610 617.