Control Interfaces. GRAFIKR Systems. 369-564a 1 10.25.11 LUT-DMX



Similar documents
OMX-RS232 Control Interface

QSE-CI-DMX Control Interface

LP Dimming Panels. GRAFIK Systems. Power Equipment. LP Dimming Panels

QSE-CI-NWK-E Control Interface

GRX-PWM Pulse Width Modulation Interface

HomeWorks QS Processor

Switching Power Module

EcoSystem Dimming Power Module for 3-wire Lutron Dimming Ballasts. EcoSystem One-Line. EcoSystem C5-BMJ-16A. EcoSystemR Dimming Module

DALI Power Module (LQSE-2DAL-D) DALI Bus 1. DALI Bus 2. HomeWorks. Wallstation. Power. Eye QS Control Power Up to 100. Module.

HomeWorks QS Wired Signature SeriesTM Keypads

Phase-Adaptive Power Module

Lighting Control Systems

SO-4SN- - SO-4SI- - 4-Button Wallstation with Off and Raise/Lower

How To Use A Lutron Power Supply

HomeWorks QS Wired seetouch Designer Keypads

TG24 / 48 LIGHTING CONTROLLER

LANTANA LUMINAIRE HI-LUME 1% ECOSYSTEM LED DRIVER L3DA4U1UMN-XXXXX

Advanced Power over Ethernet Controllers. Datasheet. Models: TS-5-POE, TS-8-PRO, TS-16-CARRIER. Gigabit PoE Ports. Intuitive Configuration Interface

Dual Technology Ceiling Mount Sensor

HSG Engineering Tech Bulletin

HMI display Installation Guide

Data Bulletin. Communications Wiring for POWERLINK G3 Systems Class 1210 ABOUT THIS BULLETIN APPLICATION INTRODUCTION.

LevelOne IFE Port PoE + 1-Port TP Industrial Fast Ethernet Switch User Manual

T7560A,B,C Digital Wall Module

5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual

Operation and Installation Manual

TOA INTERCOM SYSTEM. TOA Corporation OPERATING INSTRUCTIONS

FOSTCDR. Industrial Serial to Multimode Fiber Optic Converter PRODUCT INFORMATION B&B ELECTRONICS. Specifications Serial Technology

Electronic Control Devices The European Product Catalogue 2007

RF Maestro Local Controls

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.

Wireless DMX Connector

LIEBERT VNSA Installation Sheet

SL STRIP 400 TW LED Luminaires

HomeWorks QS Wired seetouch Architectural Keypads

LEDPAR64 USER MANUAL

AXIS T81B22 DC 30W Midspan

Linear Recessed Center Basket Fixture. Lutron

LOXONE 12 Channel Amplifier

TrueAlarm Fire Alarm Systems

How to Install a Motherboard

Applied Electronics. Commercial Dimming System UPDATE NOTICE

WxGoos-1 Climate Monitor Installation Instructions Page 1. Connections. Setting an IP Address

DMX512 TO 0-10 VOLT ANALOG CONVERTER OWNERS MANUAL

T O K I S T A R L I G H T I N G I N S T R U C T I O N M A N U A L LC-1CH-MULTI Dimmer Module

Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument D

Controlers. Controler

Connecting the Channel A

Características. Starligh SA 9 de julio 1595 Córdoba Argentina /

Gigabit Switching Ethernet Media Converters - Product User Guide

Lighting Controls ! WARNING RISK OF ELECTRIC SHOCK. Installation Instructions DESCRIPTION

NOTE: It is the responsibility of the installation organization to have only technically qualified personnel performing the installation.

Remote Power Panels with Breakers

MARS-ALE Application Note. RS-232 Computer Control Interface for LDG Electronics DTS-4/DTS-6 Desktop Coaxial Switches. Version 1.

Radiant Temperature Sensor TY7321

3500/93 System Display

DBS720 / FDS221-R / FDS221-W Sounder base, Alarm sounders

DIVISION 26 - ELECTRICAL SECTION CABLES FOR INSTRUMENTATION

NMEA 0183 INSTALLATION AND OPERATING GUIDELINES

ColorDial Pro Easily configure and control LED light shows

Electronic Control Devices The European Product Catalogue 2007

EVC40 EMERGENCY VOICE COMMUNICATION SYSTEM

FlexPoint T1/E1 Copper to Fiber Line Driver

Snapshot. LEDrain 38 USER MANUAL. Ok on Dimmer. Outdoor OK. Sound Activated. DMX/Master/Slave. 115V/230V Switch. Replaceable Fuse.

12 Volt 30 Amp Digital Solar Charge Controller Installation & Operation Manual

Schneider Automation Modbus Plus Network Installing Clustered Node Devices Version 2.0

MCR1900 Media Converter 19-Slot Chassis

Lutron High Bay Fixture Solutions

=============================== WARNING

Model CFA-24 Transparent Cable Farm Automation Switch

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

SS5C TUNABLE WHITE SOFT STRIP 4.8W 24VDC HIGH OUTPUT, COMMERCIAL GRADE 2K4K

GEU Port Gigabit Switch

D4 HP Dimmer User s Manual Rev City Theatrical, Inc.

400 Series - Mini USB Buccaneer

Product and functional description

Modular I/O System Analog and Digital Interface Modules

Total installed cost comparison study of motorized shading systems. line voltage AC system vs. low voltage Sivoia QS system

SECTION INTERIOR LIGHTING FIXTURES, LAMPS, AND BALLASTS

CAT5 VGA + Digital Audio Extender

Digital input modules

50W/100W LED Zoom User Manual

SWITCH! DESCRIPTION. ENVIRONMENTAL SPECIFICATIONS Operating Temperature: 0 C to +40 C SPECIFICATION SHEET:

Square D Clipsal DIN-Rail Four-Channel Auxiliary Input Unit

MRC High Resolution. MR-compatible digital HD video camera. User manual

LED light control using DMX512 control method

Provides one channel for Ethernet over existing

Installation instructions for Series NRX INCOM communications adapter module

INSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930

Amphenol C 091 A/B/D. Circular Connectors. Amphenol-Tuchel Electronics GmbH

PUCK LED 3W, 12V AC/DC REV

Inspired LED Price List

SECTION LOW VOLTAGE LIGHTING CONTROLS

PUCK LED 3W, 12V AC/DC REV

Duct Humidity Transmitter

IMMS-CCC. IMMS-CCC Hardwire Central Interface. Installation Instructions

Sealed Industrial Ethernet Circular IP67 Cat. 5e RJ45 Connector System

Fire Fighter Phone System Installation Instructions

PCS0100en Persy Control Services B.V. Netherlands

Transcription:

369-564a 1 10.25.11 DMX 512 Control Interface Description Allows GRAFIK EyeR lighting controls to operate lighting and other equipment that uses the DMX 512 protocol, including: - Strobes, fiber optic lighting, and LED-based lamps. - Fogger machines. - Animated characters and motorized fixtures. Converts GRAFIKR zone intensities into DMX 512 channel settings. Each zone is assigned to a DMX 512 channel. Works with GRAFIK EyeR 3000 and GRAFIK EyeR 4000 Series Control Units, as well as GRAFIK 5000T, GRAFIK 6000R, and GRAFIK 7000T Systems (see DIP switches 1 and 2). Interface does not require an address. Example of Usage A DMX 512-controlled fiber optic fixture is setup so that: Channel 5 controls color channel or dial setting. Channel 6 controls shutter open/close. The Control Unit s scenes are setup so that: Zone 5 intensity = desired fiber optic color. Zone 6 intensity = desired shutter open/close. When a scene is selected at the Control Unit: DMX 512 Interface converts new scene s zone intensities into DMX 512 channel settings. Fiber optics automatically change color and shutter open/close.

Specifications 369-564a 2 10.25.11 Power Low-voltage IEC PELV/NECR Class 2 Operating Voltage: 12/24 V- Zone/Channel Capacity Maximum total number of GRAFIK EyeR lighting zones and DMX 512 channels: GRX-3000 Control Units: Up to 48 non-continuous. GRX-4000 Control Units: Up to 64. GRAFIK 5000T Systems: Up to 128. GRAFIK 6000R Systems: Up to 512. System Communications and Capacity Low-voltage IEC PELV/NECR Class 2 wiring connects Interface to other components. One per system - no address. Does not count as one of the maximum number of addresses (Wallstations,, or Control Units) allowed on a IEC PELV/NECR Class 2 wiring link. DMX 512 Link Three terminals for connecting the to DMX 512-controlled equipment. Each terminal accepts up to two #18 AWG wires. Link must be 1000 feet or less. Link may be extended with the Lutron -RPTR interface. Link must begin and end with Link Terminators. Environment 32-104 F (0-40 C). Relative humidity less than 90% non-condensing.

Dimensions Measurements are shown in inches (mm). Front Side 369-564a 3 10.25.11 SERIES LIGHTING LIGHTING CONTROL CONTROL SYSTEM SYSTEM R R COOPERSBURG, PA 18036 PA 18036 INTERFACE CONTROL SELV SELV (CLASS 2: USA) 2: USA) 1 2 1 3 2 4 3 5 4 5 1 2 1 3 2 4 3 5 4 5 SW1 SW1 SW2 SW2 USED USED ONLY ONLY WITH WITH GRX GRX BINER FUNCTION SEE SEE INSTRUCTIONS 2 2 2 2 FUNCTION GRAFIK GRAFIK EYE EYE IN IN DMX DMX 512 512 OUT OUT G6000 G6000 IN IN DMX DMX 512 512 OUT OUT DMX DMX 512 512 IN IN DIMMING DATA DATA OUT OUT 7 3/4 (197) DIP Switches GRX GRX BINER Output Status LEDs Ground Screw Link to GRAFIK EyeR Control Units and Wallstations LED1 LED1 LED2 LED2 EARTH EARTH 6 1 12 3 2 34 45 56 CONTROL EXT EXT SW SW +V +V SW1 SW1 CONTROL EXT EXT SW SW 1 2 1 3 2 4 3 5 4 5 1 2 1 3 2 4 3 5 4 5 DMX DMX ZONE ZONE SELECT SELECT SW2 SW2 J3 J3 1 12 3 2 3 DMX DMX 512 512 OUTPUT OUTPUT 4 45 56 6 1 12 23 1 12 23 3 3 DMX DMX 512 512 OUTPUT OUTPUT ICE PELV/NECR Class 2 Wiring 6 (127) 2 1/2 (84) Mounting Mount on a 4 in (101.6 mm) square junction box. May also mount directly to the wall. Ensure that the metal casing is grounded. Connect a ground wire to the ground screw. Note that wires do not feed through the back of the unit. 4 x 4 (101.6 x 101.6) Junction Box Wall Wall Insert Wires Through Punch-Outs

Functions and Zone Capacities 369-564a 4 10.25.11 DIP Switch Settings 1 2 Interface Functionality Works with GRAFIK EyeR 3000 and 4000 Series Control Units. Enables them to operate up to 48 or 64 total GRAFIK EyeR lighting zones and DMX 512 channels. Works with GRAFIK 5000T, GRAFIK 6000R, and GRAFIK 7000T Systems. Enables them to operate DMX 512-controlled equipment. GRAFIK 5000T: Up to 128 total lighting zones and DMX 512 channels. GRAFIK 6000R: Up to 512 total lighting zones and DMX 512 channels. Allows DMX 512 stage boards to control GP Dimming Panels. 1 Used only to retrofit existing GRAFIK EyeR lighting. GP 4000 combiner function. 1 DMX 512 Link Wiring Connect the DMX 512 link terminals on the Interface to the input terminals on DMX 512-controlled equipment. Each terminal on the accepts two #18 AWG wires. Link must be 1000 feet or less. Link must begin and end with Link Terminators. DMX 512 Link Terminals on 1: DMX 512 system MON 2: DMX 512 system DATA - () 3: DMX 512 system DATA + () Connect to: DO NOT connect to MON on GRAFIK EyeR Control Unit or Processor. Pin 2 on DMX 512 equipment. Pin 3 on DMX 512 equipment. 1 For new construction, GP Dimming Panels are available with 2LinkT option, which provides DMX 512 control capability without an interface.

IEC PELV/NECR Class 2 Wiring for GRAFIK EyeR 3000/4000 Systems 369-564a 5 10.25.11 Make daisy-chain connections to the low-voltage IEC PELV/NECR Class 2 Link terminals on the front of Interface. Do not use T-taps. Run all wires in and out of terminal block. Each terminal accepts up to two #18 AWG wires. Rear View of GRAFIK EyeR Control Unit ZONE 2 ZONE 1 ZONE 4 CU WIRE ONLY ZONE 3 ZONE 6 ZONE 5 LutronR Cable GRX-CBL-346S 1000 ft (305 m) Maximum Data - Data + DMX 512 Equipment HOT/LIVE SSA CLASS 2 4 USA Class 2 IEC PELV NEUTRAL 4 CONTROL 5 6 EXT SW Wiring Terminals To additional Wallstations/ (16 Maximum; three from one Control Unit without external 12 V- power supply) Interface GRX-4000 Control Unit GP Dimming Panel DMX 512 Equipment IEC PELV/NECR Class 2 wiring for system communications

IEC PELV/NECR Class 2 Terminal Connections 369-564a 6 10.25.11 When used with GRAFIK EyeR 3000 Control Units Two #18 AWG conductors for common (terminal 1) and 12 V- (terminal 2). Ensure that the terminal 2 connection is wired correctly. Refer to GRX-3000 Specification Submittal for more details. One shielded, twisted pair #18 AWG for data link (terminals 3 and 4). When used with GRAFIK EyeR 4000 Control Units Two #12 AWG conductors for common (terminal 1) and 24 V- (terminal 2). These will not fit in terminals. Connect as shown. One shielded, twisted pair #18 AWG for data link (terminals 3 and 4). Connect Drain/Shield as shown. Do not connect to Ground (Earth) or Wallstation/. Connect the bare drain wires and cut off the outside shield. Data Link - (1) twisted, shielded pair #18 AWG 3: 4: D: Drain/Shield SW1 SW2 LED1 LED2 EARTH 4 5 4 5 4 5 6 CONTROL EXT SW DMX ZONE SELECT J3 4 5 6 +V CONTROL IEC PELV/NECR Class 2 Control wiring 1: Common 2: 24 V- EXT SW

IEC PELV/NECR Class 2 Wiring for GRAFIK 5000/6000/7000 Systems 369-564a 7 10.25.11 Connect the on the Power Panel Link. Make daisy-chain connections to the low-voltage IEC PELV/NECR Class 2 Link terminals on the front of Interface. Use Link Terminators at the beginning and end of the Power Panel Link. Refer to Processor Panel Specification Submittal for more information. Interface GP Dimming Panel Processor Panel Control Unit Control Interface Wallstations Power Panel Link Wallstation Link User Interface Link to PC IEC PELV/NECR Class 2 Terminal Connections Two #12 AWG conductors for common (terminal 1) and 32 V- (terminal 2). These will not fit in terminals. Connect as shown. One shielded, twisted pair #18 AWG for data link (terminals 3 and 4). Connect Drain/Shield as shown. Do not connect to Ground (Earth) or Wallstation/Control Interfaces. Connect the bare drain wires and cut off the outside shield. Do not connect the extra #18 AWG wire to the. Connect only to Dimming Panels as a sense line for emergency (essential) lighting. Data Link - (1) twisted, shielded pair #18 AWG 3: D: Drain/Shield 4: SW1 SW2 LED1 LED2 EARTH 4 5 4 5 4 5 6 CONTROL EXT SW DMX ZONE SELECT J3 4 5 6 +V CONTROL IEC PELV/NECR Class 2 Control wiring 1: Common 2: 32 V- EXT SW