nr 28 nr 68 nr 4 nr 1



Similar documents
Engineers Edge, LLC PDH & Professional Training

25 Years of Manufacturing Excellence INFINITY. The Intelligent 2 Wire Fire Detection System for Professionals

CAN/ULC-S Installation of Fire Alarm Systems Amendment 1. Canadian Fire Alarm Association (CFAA) D. GOODYEAR FIRE CONSULTING

Fire. The Fire Installers Mate. A guide to fire alarm systems design

Fire Alarm System Plans Submittal Guidelines For New and Existing Systems

25 Years of Manufacturing Excellence. Premier Quatro Addressable Fire Alarm System. Assessed to ISO 9001: 2008

Voice alarm system E100 the new standard for safe evacuation

SECTION PLANT INTERCOMMUNICATION SYSTEM. City of San Diego, CWP Guidelines

DTW Works Master Specification Version 2006

Print Shop/Mail Room

Appendix A - Cost Estimate Spreadsheet

FIRE-FIGHTING DESIGN BRIEF REPORT

Fire Alarm System Plans Review Checklist Property location Date of Review

Security Systems Intrusion Alarm

FIRE ALARM PANEL & SYSTEM OPERATION ID50 SYSTEM. The Fire Alarm System can be activated in the following ways :~

Fire detection equipment

Fire Alarm system Installation Guide

SECTION FIRE AND SMOKE ALARM SYSTEM. City of San Diego, CWP Guidelines

Public Address and Voice Alarm

NAVETICA. Control Devices UMTS / WiFi. Control Devices Local network. GSM unit Pag. 3. Communicator Pag. 2. Project: Pagina 1

Integrated Security System

UBC Technical Guidelines Section Edition Secure Access: General Standards Page 1 of 7

Understanding Alarm Systems

SECURITY SYSTEM PROPOSAL

PLAN REVIEW GUIDE FOR FIRE ALARM

University Design Standard. Fire Alarm Systems

GT Series. Multi-Tenant Security Intercom. Architectural and Engineering Specifications

DESTINY 1/19/96 # A

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION SECURITY SYSTEMS

AVAILABLE TO DOWNLOAD ON THE APOLLO APP. Fire Alarm Systems Design. a guide to BS5839

FIRE DETECTION AND ALARM SYSTEMS

DELAWARE STATE FIRE MARSHAL FIRE ALARM SYSTEM CERTIFICATE OF INSTALLATION

FIRE ALARM SYSTEM. A. Shop drawings shall be submitted as follows: 1. Manufacturer's published literature. for aspproval.

hong kong//china data center specifications tel: fax: internet + intellectual property + intelligence

DS-6 Intercom System Introduction

FIRE ALARM SYSTEM RECORD OF COMPLETION

PROJECT WORKPLACE DEVELOPMENT

HCS-3600MB2 Conference Main Unit

I.S :2013 Fire Detection & Alarm Systems

FIRE ALARM SYSTEM RECORD OF COMPLETION

BS5839 Part 1:2002 Overview

Data Center Security 100% UPTIME PUZZLE. Page 1

BURGLAR ALARM SYSTEMS BURGLAR ALARM SYSTEMS BURGLAR ALARM SYSTEM EURO ALARM WIRELESS BURGLAR ALARM SYSTEM OASIS

QUESTIONS & ANSWERS. Re: Invitation for Bid # (West Covina DMV Cabling, Electrical, and Hardware Installation Services)

NC State University Design and Construction Guidelines Division 26 Fire Alarm Systems

A/V and Video Conference Standards for Teaching and Learning Rooms.

CITY OF PHILADELPHIA DEPARTMENT OF LICENSES AND INSPECTIONS ANNUAL CERTIFICATION FOR FIRE ALARM SYSTEMS

Standard Comms Rooms Specification

Fire Standards & Regulations Are you confused?

Videoconference Room Guide

TAMARAC FIRE RESCUE INSTRUCTIONS FOR FIRE ALARM PRE-SUBMITTAL CHECKLIST

SECTION FIRE ALARM AND DETECTION SYSTEMS

I.S :2013 Fire Detection & Alarm Systems

SECTION FIRE ALARM AND DETECTION SYSTEM

Farm and Ranch. Security Solutions

SOLUTION GUIDE OPEN OFFICE AREA. Audio Visual System Solutions for Business. HARMAN Professional Solutions Brands:

FLEET MANAGEMENT & CAR SECURITY SYSTEM GPRS/GPS

July Robin HeliView SIP Robin CornerView SIP

Conference Room Guide

Financial Bid Format(All Inclusive)

Project No. 4 Analysis of Active Fire Alarm Systems in WTC 1 & 2. Robert J. Keough Rolf Jensen & Associates Raymond A. Grill, P.E.

TAB C-6 KEYLESS ACCESS AND SECURITY SYSTEM GUIDELINE

C. Conform to requirements of Americans with Disabilities Act (ADA).

GENERAL WIRING RULES FOR HOUSES

Guarded community solutions Easy Series for villa and apartment projects

Turnkey Projects, Conversions, Restorations & Property Management. Marsalforn - Gozo APARTMENT FINISHING EXCLUSIVE PACKAGE

TECHNOLOGY RESEARCH AND DEVELOPMENT More Than Alarm Anna Kołodziej-Saramak

PS 29M DUAL CHANNEL BELTPACK IN METAL CASE

User Guide for the DS7060 Control/Communicator

MINERVA MX MX Virtual Multi-Sensor Detectors

BELMONT FIRE DEPARTMENT FIRE ALARM SYSTEM REQUIREMENTS BFD-OFM

FireSeeker Fire Alarm Control Panel Model FS-250 Programming Manual

D287/D288/D292/D293A/D293E

Your Canadian Security Specialists. Eddie D Orazio

SECTION FIRE ALARM AND DETECTION SYSTEM

TELEPHONE CABLING TECHNOLOGY INFINITY CABLING


SECTION ACCESS CONTROL SYSTEM. CONDITIONS OF THE CONTRACT AND DIVISION 1, as applicable, apply to this Section.

FVSU REPAIR & UPGRADE FIBER OPTIC SECTION FIRE ALARM SYSTEM CONNECTIVITY

SPACE TYPE: AUTOMATED DATA PROCESSING CENTER (ADP) (MAINFRAME)

Potter Plus. Fire Alarm Control Panels

HONEYWELL COMMERCIAL FIRE/BURG PANEL UL LISTING REQUIREMENTS (Compiled from VistaFBPT Installation Instructions V1 Rev A 11/12)

Product Information S N O. Portable VIP protection CCTV & Alarm System 2

System off. Easy Series Intrusion Control Panel Making security easy now featuring wlsn* * wireless Local SecurityNetwork

CLARK COUNTY FIRE DEPARTMENT Fire Hazard & Prevention Services

AUDIO VISUAL PACKAGES TEKWORKS

System off. Easy Series Intrusion Control Panel Making security easy featuring RADION wireless peripherals

Appendix 3H A/V and Video Conferencing Standard

FIRE ALARM SYSTEM. reliable fire detection and alarm signalling system

Module 5. Fire and Emergency Alarm System Part I- Basics

T Zone Weekly Timer

The Pennsylvania State University Physical Security Office. Intrusion Alarm. Performance Specification

Finance and Administration Department 907 Billy Mitchell Blvd. P: (210) Fire Alarm Permit Application

Analogue addressable devices

Premium fire protection for a luxury-class hotel. "Kempinski Hotel The Dome" in Turkey installs a complete fire alarm system from Bosch.

Fire Alarm and Detection Systems And Central Station Monitoring Plan Submittal Guidelines

CS848E Receiver for 868GEN2 Devices Installation Sheet

conventional system operation

Security Systems Social Service Tax Act

CBD-233. Fire Alarm and Detection Systems

Transcription:

SEEB INTERNATIONAL BILL OF QUANTITIES AIRPORT ELECTRICAL WORKS NEW TERMINAL PIER ITEM ITEM DESCRIPTION UNIT QUANTITY BILL PART SECTION No. VOLUME 3 4 UNIT RATE (R.O.) (in words) (in figures) SECTION R: ELECTRICAL ENGINEERING INSTALLATIONS TELEPHONE AND DATA SERVICES Equipment Supply and install following telephone services equipment complete including cabling, looping to the main distribution panel and termination as shown on Drawing and Specification A Telephone outlet nr 28 B Data outlet nr 68 C Telephone junction box nr 4 D IDF nr 1 Carried to Part Summary

SEEB INTERNATIONAL BILL OF QUANTITIES AIRPORT ELECTRICAL WORKS NEW TERMINAL PIER ITEM ITEM DESCRIPTION UNIT QUANTITY BILL PART SECTION No. VOLUME 3 4 UNIT RATE (R.O.) (in words) (in figures) SECTION R: ELECTRICAL ENGINEERING INSTALLATIONS FIDS SYSTEM Supply and install following FIDS system equipment complete including cabling, looping to the main distribution panel and termination as shown on Drawing and Specification A LCD Monitors ceiling mounted nr 34 B LCD Monitors floor mounted nr 4 C LCD Monitors wall mounted nr 4 D Edge switch nr 3 E F Allow for 25mm dia. Conduit and 50 x 50 mm G.I. Trunking for the containment of the FIDS system. SMATV SYSTEM Supply and install SMATV system equipments complete including conduits, cabling, looping to the main panel and termination complete as mentioned in Specification Carried to Part Summary

SEEB INTERNATIONAL BILL OF QUANTITIES BILL PART ELECTRICAL WORKS NEW TERMINAL PIER ITEM ITEM DESCRIPTION UNIT QUANTITY SECTION No. VOLUME 3 4 UNIT RATE (R.O.) (in words) (in figures) SECTION R: ELECTRICAL ENGINEERING INSTALLATIONS CCTV SYSTEM Supply and install following CCTV system equipment A Fixed CCTV camera nr 20 B PTZ camera nr 6 C High focal length camera nr 4 D Multiplexer nr 2 E High definition monitors nr 4 F Controller nr 1 G H Allow for the cabling of the CCTV system including connection to existing control room. ACCESS CONTL SYSTEM Allow for the containment of the Access Control Carried to Part Summary

SEEB INTERNATIONAL BILL OF QUANTITIES BILL PART ELECTRICAL WORKS NEW TERMINAL PIER ITEM ITEM DESCRIPTION UNIT QUANTITY SECTION No. VOLUME 3 4 UNIT RATE (R.O.) (in words) (in figures) SECTION R: ELECTRICAL ENGINEERING INSTALLATIONS PUBLIC ADDRESS SYSTEM Supply and install the following Public address devices and equipments, complete including cabling, looping to the control panel and termination as shown on Drawing and Specification A 6W ceiling mounted speaker nr 337 B Noise sensing microphone for auto volume control nr 27 C Desk mounted paging microphone nr 8 D Autovolume control processor nr 15 E Amplifier surviellance system nr 17 F Allow for new public address system to connect with existing. Carried to Part Summary

SEEB INTERNATIONAL BILL OF QUANTITIES BILL PART ELECTRICAL WORKS NEW TERMINAL PIER ITEM ITEM DESCRIPTION UNIT QUANTITY SECTION No. VOLUME 3 4 UNIT RATE (R.O.) (in words) (in figures) SECTION R: ELECTRICAL ENGINEERING INSTALLATIONS FIRE ALARM SERVICES Supply and install the following fire detection and indication devices complete including cabling, looping to the control panel and termination as shown on Drawing and Specification A Optical smoke detector nr 169 B Optical smoke detector with remote interface nr 147 C Heat detector nr 19 D Break glass units nr 17 E Alarm sounder nr 17 F Signal module nr 11 G Interface unit nr 6 H Fire alarm control panel nr 1 J Allow for connection of the fire alarm system to the existing fire station Carried to Part Summary

PAGE No. 3/4/25 AMOUNT

PAGE No. 3/4/26 AMOUNT

PAGE No. 3/4/27 AMOUNT

PAGE No. 3/4/28 AMOUNT

PAGE No. 3/4/29 AMOUNT