Thermostatic element RAVV for 2-way valves



Similar documents
Thermostatic actuator RAVV - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16)

Thermostatic actuator RAVK - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16) - for 3-way valves KOVM (PN 10), VMV (PN 16)

Thermostatic actuator RAVK - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16) - for 3-way valves KOVM (PN 10), VMV (PN 16)

Thermostatic actuator RAVI - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16) - for 3-way valves KOVM (PN 10), VMV (PN 16)

Automatic Bypass Control AVDO

MAKING MODERN LIVING POSSIBLE. Thermostatic valve AVTA. Technical brochure

Thermostatic Sensor RAS-C² with RA-FN Radiator Valve (Fixed Capacity)

2-Port Self-acting Temperature Control Valve Selection for Heating and Cooling Applications

Thermostatic valve Type AVTA

Data sheet Radiator Thermostats type RA 2000 Valve bodies type RA-FN and RA-G

Data sheet Thermostatic sensors type RA 2000

Data sheet ECC 12 and 22

Solenoid valves 2/2-way direct-operated Type EV210A

Self-operated Temperature Regulators Temperature Regulator Type 1u

Flow controller with integrated control valve (PN 16, 25, 40*) AFQM, AFQM 6 - return and flow mounting

Integrated Presetting Valves - for Normal Volume Flows RA-N and for Small Volume Flows RA-U

Integrated Presetting Valves for Normal 013G0372 and Small 013G0373 Volume Flows

Thermostatic Actuators

Assisted lift operated 2/2-way solenoid valves Type EV250B

V5001S. Kombi-S Shutoff Valve. Product specification sheet

Type 3353 Angle Seat Valve

Operators manual Basic water heater

Pressure switches and thermostats, type KPS

REGULATORS 175/153 Series

CoolTop. A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60

Automatic balancing valves ASV

DN [mm] [m 3 /h] Characterizing disk Dimensions / Weights see «Dimensions and weights», page 3 Motorizing

HDA

Seated valves (PN 16) VF 2 2-way valve, flange VF 3 3-way valve, flange

Itho Products for Hot and Boiling water. product-

Thermostatic expansion valves type TR6 REFRIGERATION AND AIR CONDITIONING. Technical leaflet

RADIATOR VALVES / MANIFOLD ASSEMBLIES AND DIVERTERS

Blowdown vessels Meeting the requirements of HSE PM60

Stainless Steel Single and Dual Circulation Kits

Technical data. Danfoss DHP-A

3/2-way Solenoid Valve, direct-acting, NC or NO

Overview of types. Technical data

Mikrotherm. Manual radiator valves. To be precise.

Solenoid valves Type EVU

Self-operated Pressure Regulators Universal Pressure Reducing Valve Type 41-23

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)

3/2-way Mini Solenoid Valve

Water valves REFRIGERATION AND AIR CONDITIONING. Fitters notes

Guide rail bracket (for adjustable heads)

Valve systems Base plates, according to standard ISO Brochure

EVAC ONLINEVAC TECHNICAL DATA EVAC ONLINEVAC 16, 24 V DC. Required maintenance space 700 mm. Required maintenance space 200 mm 360 Ø13

VALVES FOR REFRIGERATING SYSTEMS

Direct steam injection humidifiers

ECOCIAT. Domestic hot water heat recovery unit

Low-H2O valves Y EARS

PRESSURE REDUCER AND RELIEF VALVES WITH METALLIC BELLOW FOR WATER STEAM

4 Posiflow Proportional Solenoid Valves

Type overview. Technical data

Geothermal Alliance of Illinois. TXVs Theory and Fundamentals John Haug Senior Application Engineer Emerson Climate Technologies - Flow Controls

TN2000 Series Pneumatic Piston Actuators for DN125 to DN300 SPIRA-TROL Series Control Valves

Solar Hot Water Heaters

Double-Headed Screw 1. 3/4" FIP x 3/4" MIP x 1/4" hole 2. 3/4" Fip x 3/4" MIP. Feed Water Connector 1. 1/2" FIP x 1/2" MIP x 1/4" OD 2. 3.

How To Use A Flowmeter

RI27-J CNG REDUCER INSTALLATION PROVISIONS & WARNINGS

I N S T A L L A T I O N I N S T R U C T I O N S F O R T H E H i l k o i l Energy S aving Hot Water Kit

PRESSURE REDUCING VALVES

Stainless steel process fittings

Residential/Commercial Gas Condensing High Efficiency Tankless Water Heaters

1 DESCRIPTION OF THE APPLIANCE

Installation and maintenance instructions. Danfoss Vent

1. Geo Vertical 2. Geo Horizontal

TABLE 1. Rugged cast aluminum alloy casing,celcon waterways with nichrome parts White (unless stainless steel housing)

OEM Pressure Transmitters for heavy-duty applications, Type MBS 1200 and MBS 1250

STABITHERM INSTALLATION & SERVICE BOOKLET

Technical Guide. Thermostats Air Conditioning

3/2- and 2/2-way cartridge valve type BVE

SLAM-SHUT VALVE. Type OSE. Europe, Middle East, Africa and Asia Pacific Documents Only. Process Management TM

SHOWER WATER HEATER MODEL BS 35 / 45 / 60 BS 35 E / 45 E / 60 E OPERATION AND INSTALLATION INSTRUCTIONS

ThermoSorb Desiccant Dryers

Isotemp Basic, Slim/B & Slim Square

SQUARE D INDUSTRIAL CONTROL PRODUCTS

Max primary circuit temperature 90ºC Max primary circuit temp. 90ºC Max secondary circuit temperature 45ºC Max secondary circuit temp.

FLOAT SWITCHES FLOW SWITCHES FOR LIQUIDS PRESSURE SWITCHES

Materials : Cast iron body

Butterfly Valves PN 6/10/16 for flanged connection

Electrically operated valves Series M-05, 3/2-, 5/2- and 5/3-way G1/8 650 and 750 Nl/min (0.661 and Cv)

Range Tribune HE Solar Unvented Direct and Indirect Cylinders

Price List Rev.2. AGUIDROVERT S.L. c/ Cervantes 20, Zaragoza (Spain) Tel.: Fax:

VSO MAX HP High Flow Proportional Valve

VAD Variable Area Desuperheaters

Accumulators and Receivers

Pilot Operated Pressure Reducing Valve PRV 47 (Steel) PRV47I (St.Steel)

Installation and Operation Instructions Domestic hot water modules: FriwaMidi DN 20 FriwaMaxi DN 25

FLASH TANK ECONOMIZER PRODUCT GUIDE

Heat. Investigating the function of the expansion valve of the heat pump. LD Physics Leaflets P Thermodynamic cycle Heat pump

TA-FUS1ON. Fully adjustable Kvs control and balancing valves. That s just two good.

RI27 CNG REDUCER INSTALLATION PROVISIONS & WARNINGS

Commercial Gas Cooking Thermostats

THERMOSTATIC ACTUATORS WITH LIQUID-FILLED SENSITIVE ELEMENTS AND TEMPERATURE LOCKING

820 NOVA mv THERMOPILE POWER SUPPLY THERMOELECTRIC SAFETY DEVICE SERVO-CONTROLLED PRESSURE REGULATOR SHUT-OFF SOLENOID VALVE.

Neuton Solar Power Diverter Quick Installation Guide

Confidential. Proportional reducer D386 ATEX. Male base connector View from weld side

INSTALLATION AND OPERATION INSTRUCTIONS - (LOW FLOW MODELS) (Before installation, compare electrical needed for the model of heater selected)

VAD. Variable Area Desuperheaters

Transcription:

Description / Application RAVV is a self-acting thermostatic element which can be combined with 2-way valve bodies RAV-/8, VMT-/8 or VMA 15. RAVV is used to control temperatures in small hot water cylinders and to control flow temperatures in central heating systems. There is a special version with a section of the capillary tube coiled up to function as minimum temperature sensor. This version can be used to control air heating coils. RAVV-RAV and RAVV-VMT - closes on rising sensor temperature - must be installed in the flow pipe - is dimensioned for pressure stage (PN) 10, max.120 C RAVV-VMA - closes on rising sensor temperature - must be installed in the flow pipe - is dimensioned for pressure stage (PN) 16, max.130 C Principles Hot water cylinder Air heating coil Ordering Setting Capillary tube Max. Type range lenght sensor temperature Code No. C m C 10-38 1.5 120 013U1255 1) RAVV 10-38 5.0 2) 120 013U1256 27-57 1.5 120 013U1252 1) 40-70 1.5 120 013U1251 1) 1) Incl. R 1 p / 2 capillary tube gland 2) Effektive lenght including minimum temperature sensor Accessories Material Code No. Brass 993N3568 Sensor pocket Stainless steel 993N3615 SIBC VD.52.O2.02 Danfoss 05/02 1

Valve bodies Type Connection 1) k v Inlet Outlet m 3 /h Code No. RAV 10/8 R 3 p /8 3) R 3 /8 3) 1.1 013U0012 RAV 15/8 R 1 p / 3) 2 R 1 / 3) 2 1.2 013U0017 RAV 20/8 R 3 p / 3) 4 R 3 / 3) 4 1.5 013U0022 RAV 25/8 R p 1 3) R 1 3) 1.6 013U0027 VMT 15/8 2) G 3 / 4 A 4) G 3 / 4 A 4) 1.2 065F0115 VMT 20/8 2) G 1 A 4) G 1 A 4) 1.5 065F0120 VMT 25/8 2) G 1 1 / 4 A 4) G 1 1 / 4 A 4) 1.6 065F0125 VMA 15 0.4 065F2031 VMA 15 0.6 065F2032 VMA 15 G 3 / 4 A 4) G 3 / 4 A 4) 0.8 065F2033 VMA 15 1.1 065F2034 VMA 15 1.7 065F2035 1) The capacity (k v ) iapplies to a P-band of 6 C. Other P-band, see "Data". 2) Ordering cooper fittings, see "Accessories" 3) According to ISO 7/1 4) According to ISO 228/1 Accessories VMT Type Copper fittings (delivered in boxes of 10) Code No. 15 1 013G4125 VMT 15 16 1 013G4126 18 1 013G4128 VMT 20 18 1 013U0134 22 1 013U0135 VMT 25 28 1 013U0140 Accessories VMA Typ Nipple sets Code No. VMA 15 Set of weld-on nipples 003N5090 VMA 15 Set of nipples with external threads 003N5070 Data k v (m 3 /h) Max. Max. Max. Max. Type for a P-band in C of working differential test flow pressure pressure pressure temperature RAVV- 2 4 6 8 10 12 bar bar bar C RAV 10/8 0.6 0.8 1.1 1.2 1.3 1.4 RAV or VMT 15/8 0.6 0.9 1.2 1.3 1.5 1.6 RAV or VMT 20/8 0.7 1.2 1.5 1.8 2.1 2.3 10 0.8 16 120 RAV or VMT 25/8 0.7 1.2 1.6 2.0 2.3 2.6 VMA 15 (k vs = 0.4) 0.2 0.3 0.4 5 1) VMA 15 (k vs = 0.63) 0.3 0.5 0.6 VMA 15 (k vs = 1.0) 0.4 0.7 0.8 16 2 1) 25 130 VMA 15 (k vs = 1.6) 0.4 0.8 1.1 VMA 15 (k vs = 2.5) 0.7 1.2 1.7 1 1) 1) In installations requiring a low-noise function the differential pressure is not to exceed 1 bar. 2 VD.52.O2.02 Danfoss 05/02 SIBC

Design Materials, parts in contact with water Valve body: Ms 58, nickel plated Valve cone: NBR-rubber Pressure pin: Stainless steel 18/8 O-ring: EPDM-rubber Sensor: Cu, nickel plated Sensor pocket: Brass or stainless steel 1. Setting knob 2. Setting spring 3. Bellows element 4. Gland 5. Bottom screw 6. Valve body 7. Valve cone 8. Remote sensor 9. Capillary tube gland Setting Relation between scale figures and closing temperature. The values given are approximate. Installation The valve body must be fitted in the flow pipe with the flow in direction of the cast-in arrow. The flow temperature must be min. 15 C higher than the set closing temperature. The sensor must be fitted in position from horizontal to vercally down. The sensor must always be placed in a pocket when the temperature is to be measured directly in a medium. SIBC VD.52.O2.02 Danfoss 05/02 3

Sizing Example: Temperature control for hot water service Given Load: Cooling (flow - return): 20 C 14 kw (12000 kcal/h) Flow volume: 12 20 = 0.6 m 3 /h Differential pressure p across the valve: 0.12 bar Required Correct valve size Method From the flow volume (0.6 m 3 /h) and the differential pressure (0.12 bar) read off the necessary k v -value in the diagram = 1.75. In this example, a P-band of 6 C is required. From the k v -columns in the table, under 6 C, find the appropriate valve body. Here, the most suitable valve body is RAV 25/8 or VMT 25/8 with a k v -value of 1.6. 4 VD.52.O2.02 Danfoss 05/02 SIBC

Dimensions RAVV-RAV/8 RAVV-RAV/8 d d Widths 2 across flats L L 2 L 3 L 4 L 5 H 1 H 2 S 1 S 2 DN ISO 7/1 mm mm mm mm mm mm mm mm mm 10 R 3 p /8 R 3 /8 59 85 26 52 22 45 93 22 27 15 R 1 p / 2 R 1 / 2 66 95 29 58 26 45 93 27 30 20 R 3 p / 4 R 3 / 4 74 106 34 66 29 45 93 32 37 25 R p 1 R 1 90 125 40 75 34 58 106 41 46 RAVV-VMT 15/8 Widths a b L 1 L 2 H 1 across flats DN mm ISO 228/1 mm mm mm S mm 15 15/ 16/ 18 G 3 / 4 A 66 90 93 30 20 18/ 22 G 1 A 74 101 93 37 25 28 G 1 1 / 4 A 90 120 106 45 RAVV-VMT RAVV-VMA a L L 1 L 2 S DN ISO 228/1 mm mm mm mm 15 G 3 / 4 A 65 131 139 27 RAVV-VMA Pocket sensor SIBC VD.52.O2.02 Danfoss 05/02 5

6 VD.52.O2.02 Danfoss 05/02 SIBC

SIBC VD.52.O2.02 Danfoss 05/02 7

8 VD.52.O2.02 Danfoss 05/02 SIBC