Bypass switches. Type B-1 and type B-2. Answers for energy.



Similar documents
Vertical Break Parallel (VBP) / Vertical Break Slant (VBS)

S&C TripSaver Dropout Recloser. For enhanced lateral circuit protection at 15 kv and 25 kv

Hyperlinks are Inactive

High-Voltage Compact Switchgear 3AP1 DTC for 145 kv and 245 kv

OVR Three-Phase Recloser and PCD Control Style Guide 1VAL SG October 13, 2009 Revision F

Siemens Fusesaver. Highest availability and cost savings for your MV distribution network.

OVR-3SP Recloser with PCD Control Style Guide 1VAL SG March 30, 2009 Revision B

When power interruptions happen.

Customer Substation Manual 08/05/02

Unit substation solutions with type SIMOSEC primary switches quick reference guide E50001-F710-A389-X-4A00. Answers for energy.

Step Voltage Regulators

Fundamentals of Modern Electrical Substations Part 1: Mission of Electrical Substations and their Main Components

Submit shop drawings for equipment provided under this section Shop drawings shall indicate:

Standex-Meder Electronics. Custom Engineered Solutions for Tomorrow

PG&E Transmission Interconnection Handbook. Section L3: SUBSTATION DESIGN FOR LOAD-ONLY ENTITIES AND TRANSMISSION-ONLY ENTITIES

2a. IEM Indoor Metal Clad Medium Voltage Switchgear 15KV a. Section INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std.

Specifications. S&C Power Fuses Types SM and SMLa. For use with SM Refill Units or SMU Fuse Units. Indoor Distribution (4.16 kv through 34.

Kuhlman Electric Corporation Volt Instrument Transformers

Lightning Arresters P KVA P KVA. Description & Installation

Distribution Voltage Regulators

MEDIUM AND HIGH VOLTAGE CAPACITORS, CAPACITOR BANKS AND SYSTEMS

CONSTRUCTION STANDARD ELECTRIC OPERATIONS ORGANIZATION

OUTDOOR DISCONNECTORS A division of ACTOM (Pty) Ltd

Secondary Unit Substations

Cable Accessories. for Extruded Dielectric Cable 69kV - 230kV Rated. Catalog Python13

Medium Voltage Electrical Distribution

AutoLink Three-Phase Sectionalizer Specifications. Scope. General. Applicable Standards. Operating principle

HVL 5 38 kv Load Interrupter Switchgear. The Standard for Performance, Protection and Dependability

How To Choose A Transformer

Multiple Meter Installation Amperes Per Position -Single Phase, Self-contained

The following components are common to most cubicles; this example is an ABB HK cubicle.

2.4 kv to 34.5 kv SP-1099

Installation. S&C Loadbuster Disconnect Switches Branch Feeder, Main Feeder, Crossarm, and Station Styles

The Impact of Transmission Cable System Construction and Design on Commissioning Test Options & Results

AMPSEAL* Automotive Plug Connector and Header Assembly

Pilot-wire differential relay for lines with two or more terminals

UNIVERSITY OF WASHINGTON Facilities Services Design Guide. Electrical. Switchboards. Basis of Design. Design Evaluation

Distribution Dry Type Transformers

Circuit Protection. Copper Cable Limiters (600Vac) Copper/Aluminum Cable Limiters (250Vac)

Takfan Machinery and Mould Co Ltd. Plug in Bushing. LV Monoblock. RMU Bushing. 4 Way CT Terminal.

LV MCC LOW VOLTAGE SWITCHGEAR MOTOR CONTROL CENTRE PRODUCT GUIDE

3. TYPES OF SERVICE AVAILABLE. 3.1 Scope

TMDS Smart Monitor. Solutions for transformer life-cycle management. Answers for energy.

Rule Fast Track Analysis for National Life Insurance Co.

C E R T I F I C A T E O F C O M P L I A N C E

S. C. Electric Cooperative s Specification for a Three-Phase, Padmounted URD Transformer (Revised 12/2014)

Power products and systems. Intelligent solutions for power distribution Zone concept

LUCCI AIRFUSION QUEST II CEILING FAN

Radial Distribution Test Feeders

Low and Medium Voltage Division Erlangen, February 18, New MCCBs for Increased Line Protection and Availability

VC Series Zone Valves BALANCED 2-WAY AND 3-WAY HYDRONIC VALVES

CutMaster Major External Replacement Parts

Arktite Heavy Duty Circuit Breaking Plugs and Receptacles

Advantages of Fixed Circuit Breaker Switchgear

Directory chapter 04

ELECTRIC METERING COMMERCIAL & INDUSTRIAL

picomax The Pluggable Connection System

Lighting Packages. 230 VAC Fluorescent Enclosure Light:

Type MOST oil switch. Technical Data Contents. Effective October 2013 Supersedes March 2000

Installation, Operation and Maintenance Instructions Viper -S Solid Dielectric Reclosers Three Phase, Vacuum Recloser.

GEK-90214B. GE Lift Truck. User s Guide 144D2933G1 144D2912G1 144D2911G5

VD4. Vacuum circuit-breaker

6000 Series Buccaneer. 30 twist locking Tamperproof lock prevents accidental un-mating. Cat 5e shielded coupler Maintains shielding

SPECIFICATION COG-2007

Terminal Blocks & Power Distribution Terminal Blocks. Make your connection

METER REQUIREMENTS GENERAL REQUIREMENTS SECTION D

WINDING RESISTANCE TESTING

Dead Tank Circuit Breaker 72PM40-C Proven reliability through common platforms

Arc Terminator Active Arc-Resistant Switchgear

Permissible ambient temperature Operation Storage, transport

Standard Buccaneer - USB

MEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV

SlimSeal SSL Connector. Now Available in 1 Position. Free Hanging Version

Siemens TMDS transformer monitoring and diagnostic system. Solutions for transformer life-cycle management. Answers for energy.

Type K current limiting fuse canister Technical information and installation guide

Single-phase ( V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable

Corner-Grounded Delta (Grounded B Phase) Systems

SIMATIC. ET 200S distributed I/O Digital electronic module 8DO DC24V/0.5 A (6ES7132-4BF00-0AA0) Preface. Properties 1. Diagnostics 2.

Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling

SIRCOVER. Manual changeover switches from 125 to 3200 A. Changeover switches. Function. Advantages. The solution for.

LVA Take Offs in Bid Manager

Spending too much to maintain aging switchgear? Circuit breaker solutions from Square D Services.

Chemical resistance Accidental

ELECTRIC UTILITY SERVICE EQUIPMENT REQUIREMENTS COMMITTEE, EUSERC

Selector Switch Type 08

Metallic and Non-Metallic Air Conditioning Disconnects. A Complete Family of. Disconnects with Exclusive Time Saving Features

Cable/Conduit Conversion

ISIO 200. Binary Input/Output (I/O) Terminal with IEC Interface

T-05-S2. Rotary drive without spring return. Technical data sheet. Description. Technical data. Actuators

25-kV Apparatus Bushings B Series (bolt-in) for Elbow to Air-Insulated Service 200 Amp, 600 Amp and 1250 Amp

June July 18, of 7

Pump Specifications 405 Series Commercial Drain Pump (High-Temp) 2 Solids handling

Product Specification instalert Rapid Messenger Variable Message Sign

Current distribution Comb busbars for Declic and SFT residential devices

Union County Public Schools. Facilities Department. Electrical. Safe Work Practices

Low Voltage Disconnect Switches. NFPA79 and UL508A Industrial Machinery Operating Handle Requirements White Paper

What ensures easy and fast wiring?

Current and voltage measuring relays

Power transformers. Special transformers Railway

Power Transmission and Distribution. Shunt reactors for medium and highvoltage. From development to use

Transcription:

Bypass switches Type B-1 and type B-2 Answers for energy.

Eliminate voltage regulator bypass switch problems with type B-1 and type B-2 Overview Type B-1 The Bridges Electric type B-1 regulator bypass switch is a simple and rugged three-bladed disconnect switch. Each blade is independently operated and is readily visible to the operator. The major safety feature of the type B-1 is that the bypass blade can be visually checked to ensure that it is open. This helps eliminate the possibility of the regulator being shortcircuited when it is restored to service. Many available options and accessories make the type B-1 a flexible solution for regulator bypass schemes. Type B-2 The Bridges Electric type B-2 oil circuit recloser (O.C.R.) (or regulator) bypass switch utilizes the same blade and contact material as the type B-1. Its design provides clearance for an O.C.R. bypass scheme, but can be used as a regulator bypass. Versatility is provided with optional backplate sets for underhung mounting or an angled pole bracket for mounting directly to the pole. Many available options and accessories make the type B-2 a flexible solution for O.C.R. and regulator bypass schemes. 2

Type B-1 regulator bypass: 600 A Cat. no. NOM kv MAX kv kv Amps BIL Cont. Mom. A B C D E F G H J K L M N P Q Insulators 610 14.4 15 110 600 40,000 4 2 28 30 5 8 12 8 10.8 11.8 14.3 15.3 11.5 19.7 29.7 2 1/4 710 23 25 150 600 40,000 4 2 31 33 5 10 15 10 12.8 13.8 16.3 17.3 14.5 22.7 32.7 D.B.C. 615 14.4 15 110 600 40,000 4 2 31 33 5 10 15 10 12.8 13.8 16.3 17.3 14.5 22.7 32.7 715 23 25 150 600 40,000 4 2 34 36 5 14 18 14 16.8 17.8 20.3 21.3 17.5 25.7 35.7 3 D.B.C. 815 34.5 38 200 600 40,000 6 2 40 42 5 18 24 18 20.8 21.8 20.3 21.3 23.5 31.7 41.7 H = Loadbreak hooks K = Cable connector #6-397.5 MCM ACSR #6-500 MCM copper QB = Quick break Example: 610CQBT = type B-1, 15 kv, 110 kv BIL, 600 A, polymer insulators, quick break, tinned terminal pads 3

Type B-1 regulator bypass: 900 A Cat. no. NOM kv MAX kv kv Amps BIL Cont. Mom. A B C D E F G H J K L M N P Q Insulators 630 14.4 15 110 900 40,000 4 2 28 30 5 8 12 8 10.8 11.8 14.3 15.3 11.5 19.7 29.7 2 1/4 730 23 25 150 900 40,000 4 2 31 33 5 10 15 10 12.8 13.8 16.3 17.3 14.5 22.7 32.7 D.B.C. 635 14.4 15 110 900 40,000 4 2 31 33 5 10 15 10 12.8 13.8 16.3 17.3 14.5 22.7 32.7 735 23 25 150 900 40,000 4 2 34 36 5 14 18 14 16.8 17.8 20.3 21.3 17.5 25.7 35.7 3 D.B.C. 835 34.5 38 200 900 40,000 6 2 40 42 5 18 24 18 20.8 21.8 20.3 21.3 23.5 31.7 41.7 H = Loadbreak hooks K = Cable connector #6-397.5 MCM ACSR #6-500 MCM copper QB = Quick break Example: 630CQBT = Type B-1, 15 kv, 110 kv BIL, 900 A, polymer insulators, quick break, tinned terminal pads 4

Type B-1 regulator bypass: 1,200 A Cat. NOM MAX kv Amps no. kv kv BIL Cont. Mom. A B C D E F G H J K L M 625 14.4 15 110 1,200 61,000 6 3 37 39 19 10 10 13.3 14.8 17.4 31 41 725 23 25 150 1,200 61,000 6 3 40 42 22 10 14 17.3 18.8 20.4 34 44 825 34.5 38 200 1,200 61,000 6 3 46 48 28 10 18 21.3 22.8 26.4 40 50 Insulators 3 D.B.C. QB = Quick break Example: 625CQBT = Type B-1, 15 kv, 110 kv BIL, 1,200 A, polymer insulators, quick break, tinned terminal pads 5

Type B-1 regulator bypass: 600 A with Saf-T-Gap interrupter (600 A loadbreak) Cat. NOM MAX kv Amps no. kv kv BIL Cont. Mom. A B C D E F G H J K L M 675 14.4 15 110 600 40,000 4 2 31 33 15 8 10 13.8 16.3 14.5 23.25 33.4 775 23 25 150 600 40,000 4 2 34 36 18 8 14 16.8 17.5 17.5 26.25 36.4 875 34.5 38 200 600 40,000 6 3 40 42 24 12 18 20.8 21.3 23.5 32.25 42.4 Insulators 3 D.B.C. K = Cable connector #6-397.5 MCM ACSR #6-500 MCM copper Example: 675CT = Type B-1, 15 kv, 110 kv BIL, 600 A, polymer insulators, tinned terminal pads 6

Type B-1 regulator bypass: 900 A with Saf-T-Gap interrupter (600 A loadbreak) Cat. NOM MAX kv Amps no. kv kv BIL Cont. Mom. A B C D E F G H J K L M 695 14.4 15 110 900 40,000 4 2 31 33 15 8 10 13.8 16.3 14.5 23.25 33.4 795 23 25 150 900 40,000 4 2 34 36 18 8 14 16.8 17.5 17.5 26.25 36.4 895 34.5 38 200 900 40,000 6 3 40 42 24 12 18 20.8 21.3 23.5 32.25 42.4 Insulators 3 D.B.C. K = Cable connector #6-397.5 MCM ACSR #6-500 MCM copper Example: 695CT = Type B-1, 15 kv, 110 kv BIL, 900 A, polymer insulators, tinned terminal pads 7

Type B-1 regulator bypass: 1,200 A with Saf-T-Gap interrupter (600 A loadbreak) Cat. NOM MAX kv Amps no. kv kv BIL Cont. Mom. A B C D E F G H J K L M 685 14.4 15 110 1,200 61,000 5 2 37 39 19 10 10 13.3 14.8 17.4 31.6 41.6 785 23 25 150 1,200 61,000 5 2 40 42 22 10 14 17.3 18.8 20.4 34.6 44.6 885 34.5 38 200 1,200 61,000 6 3 46 48 28 10 18 21.3 22.8 26.4 40.6 50.6 Insulators 3 D.B.C. Example: 685CT = Type B-1, 15 kv, 110 kv BIL, 1,200 A, polymer insulators, tinned terminal pads 8

Options The Type B-1 regulator bypass disconnects are available with quick break and pole bracket options. Quick break option Pole bracket option 9

Type B-2: O.C.R. (or regulator) bypass 600 A Cat. no. NOM MAX kv Amps kv kv BIL Cont. Mom. A B C D E F G 603 14.4 15 110 600 40,000 15.8 12 8 12.97 12 22.5 12 703 23 25 150 600 40,000 18.8 15 10 14.97 15 25.5 15 803 34.5 38* 150 600 40,000 21.8 18 10 14.97 18 30 18 * Grounded wye system only H = Loadbreak hooks K = Cable connector #6-397.5 MCM ACSR #6-500 MCM copper L = Bypass blade in left hand position 01 = Angled bypass blade Example: 603-01CPT = Type B-2, 15 kv, 110 kv BIL, 600 A, angled bypass blade, polymer insulators, pole mount bracket, tinned terminal pads 10

Type B-2: O.C.R. (or regulator) bypass 900 A Cat. no. NOM MAX kv Amps kv kv BIL Cont. Mom. A B C D E F G 604 14.4 15 110 900 40,000 15.8 12 8 12.97 12 22.5 12 704 23 25 150 900 40,000 18.8 15 10 14.97 15 25.5 15 804 34.5 38* 150 900 40,000 21.8 18 10 14.97 18 30 18 * Grounded wye system only H = Loadbreak hooks K = Cable connector #6-397.5 MCM ACSR #6-500 MCM copper L = Bypass blade in left hand position 01 = Angled bypass blade Example: 604-01CPT = Type B-2, 15 kv, 110 kv BIL, 900 A, angled bypass blade, polymer insulators, pole mount bracket, tinned terminal pads 11

Type B-2: O.C.R. (or regulator) bypass substation style 600 A Cat. no. NOM MAX kv Amps kv kv BIL Cont. Mom. A B C D E F G 605 14.4 15 110 600 40,000 19.3 15 10 15.6 15 27.25 15 705 23 25 150 600 40,000 22.3 18 14 19.6 18 30.25 18 805 34.5 38 200 600 40,000 28.5 24 18 23.6 24 36.25 24 H = Loadbreak hooks K = Cable connector #6-397.5 MCM ACSR #6-500 MCM copper L = Bypass blade in left hand position Example: 605CPT = Type B-2, 15 kv, 110 kv BIL, 600 A, polymer insulators, pole mount bracket, tinned terminal pads 12

Type B-2: O.C.R. (or regulator) bypass substation style 900 A Cat. no. NOM MAX kv Amps kv kv BIL Cont. Mom. A B C D E F G 606 14.4 15 110 900 40,000 19.3 15 10 15.6 15 27.25 15 706 23 25 150 900 40,000 22.3 18 14 19.6 18 30.25 18 806 34.5 38 200 900 40,000 28.5 24 18 23.6 24 36.25 24 H = Loadbreak hooks K = Cable connector #6-397.5 MCM ACSR #6-500 MCM copper L = Bypass blade in left hand position Example: 606CPT = Type B-2, 15 kv, 110 kv BIL, 900 A, polymer insulators, pole mount bracket, tinned terminal pads 13

Options Mounting bracket options 14

Three-phase recloser bypass assembly Three type B-2 recloser bypass switches factory installed on an aluminum or fiberglass arm Aluminum or fiberglass arm mounted on adjustable pole gain, which provides the option of angling assembly based upon field conditions Single-point lift bracket Stable switching action while allowing for a visible indication of a break in the circuit Easy identification of the load and source sides in equipment while the circuit is in its normal configuration Bypass blades can be easily recognized as open or closed Contact factory for application information 15

Published by and copyright 2010: Siemens AG Energy Sector Freyeslebenstrasse 1 91058 Erlangen, Germany Siemens Energy, Inc. 99 Bolton Sullivan Drive Heber Springs, AR 72543 Phone: +1 (501) 362-8296 Toll-free: +1 (800) 347-6659 Order No. E50001-F630-A117-X-4A00 Printed in USA BU 2010115153054664F BR 0710.5 All rights reserved. Trademarks mentioned in this document are the property of Siemens AG, its affiliates, or their respective owners. Subject to change without prior notice. The information in this document contains general descriptions of the technical options available, which may not apply in all cases. The required technical options should therefore be specified in the contract. www.usa.siemens.com/energy