The power module is Feature Number 8800-F2-901.



Similar documents
About the BitStorm 6051 POTS Splitter

Refer installation of power supplies to qualified service personnel.

What is the Fan Tray Assembly?

About the HotWire Slot Standalone Shelf

5-Slot Housing and FrameSaver 9000 Series Access Carrier AC Power Supply Installation Instructions

HOTWIRE 8810 DIGITAL SUBSCRIBER LINE ACCESS MULTIPLEXER (DSLAM)

HP UPS R1500 Generation 3

MCR1900 Media Converter 19-Slot Chassis

HP 16/18-Port Cable Management Kit Installation Guide

HP R12000 and R18000 DirectFlow UPS User Guide

How to Set Up Your NSM4000 Appliance

Argus Technologies Pathfinder10kW to Cordex3.6kW Shelf Replacement Procedure

HP 36-Port InfiniBand Switch Cable Management Kit Installation Guide

HP ProLiant DL380 G6 Carrier-Grade Server Read Before Install

Express5800/120Ed. Rack Mount Kit Installation Procedures PN:

PS4-24 OWNERS MANUAL 24 VAC 90 WATT WALL MOUNTED CCTV POWER SUPPLY

ASKING FOR ASSISTANCE

Installation and Operation Guide PD4600 Series Converter Replacement

UPGRADING AND SERVICING GUIDE

IP DSLAM IDL Quick Installation Guide

430 Power/Electronics Replacement

Intel RAID Maintenance Free Backup Unit 4 Quick Installation User's Guide

TraceTek TTDM Series Leak Detection and Location Modules Replacement Parts Installation Instructions

How To Install A Cisco Cisco 520-T1 Router On A Network Card (Cisco) With A Network Cable (Cio) And A Network (Cnet) (Coconc) (Net) And An Ipo (

Hotwire 6350 ReachDSL Modem Overview

Advantium 2 Plus Alarm

BX7000 Multi-Access Gateway Getting Started Guide

AI120 AIswitch Series 120 Chassis

VOIP-500 Series Phone Quick Installation Guide

Product Documentation on the World Wide Web

Co-location Interconnect Power Panel (CIPP) Installation Guide

INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate Locks

Triple Expansion Chassis

ATS Overhead Table Shelf System INSTRUCTION MANUAL

INSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930

Taurus Super-S3 LCM. Dual-Bay RAID Storage Enclosure for two 3.5-inch Serial ATA Hard Drives. User Manual March 31, 2014 v1.2

Step 1. Item 6. Item 1

DE1600 DSA E-Series iscsi Disk Arrays. en Quick Install Guide

Acano solution. Acano Solution Installation Guide. Acano. January B

Uninterruptible Power Supply. 500 kva kva

Compaq Presario Desktop Products. Upgrading and Servicing Guide

Installation Instructions

This page is subject to proprietary rights statement on last page

LIEBERT VNSA Installation Sheet

PS6500 Storage Arrays Rack Mount Instructions

Quick Start Guide Series 1 RU Gen 2 Data Center Switches. Arista Networks. DCS-7150S-64 PDOC

Hotwire 6310 MVL Modem with Inline Phone Filter Installation Instructions. Contents. Hotwire 6310 MVL Modem Overview

INSTALLATION INSTRUCTIONS

StorTrends 3400 Hardware Guide for Onsite Support

PowerFlex 700H and 700S AC Drives Frame 11 Main Fan Capacitor Replacement Kit

Installation and Operation Guide for PD4000 Series Power Control Center

I NTERFACE CABLE ADAPTER MODULE

Power Supply Guide Version 1.0 for D-Show

42U/45U 28" Wide Rack Installation & Service Guide

SOLAR ELECTRIC MODULE ES-124 & ES-62T Owners Manual and Installation Guide

Vehicle Power Install Kit

BODi rs BD004 Series Bandwidth-on-Demand Internet with Reliability and Survivability. Quick Start Guide NOTES

Hotwire 5620 RTU Installation Instructions. Contents. Hotwire 5620 RTU Overview. Document Number 5620-A2-GN11-40 September 2001

AMERBRITE UNDERWATER WHITE LED POOL LAMP

CONTENTS TOOLS REQUIRED: Ratchet 13mm Socket 10mm Socket Phillips Screwdriver Pliers Panel Removal Tool. Amp Installation

Small form factor bay converter and hard drive installation

FTW 175 VERIZON Wireless Monitoring System Reference Manual Part Number VERIZON

UPDATEUPDATEUPDATE. Converting the tower chassis to a rack-mount chassis. A - M To mount outer member to rack

LS-1 Series Tungsten Halogen Light Sources Installation and Operation Instructions

BitStorm 2600 IP DSLAM

HM-W536 Install Guide

MX5, MX10, MX40, and MX80 3D Universal Edge Router Quick Start

Product Documentation on the World Wide Web

Generator Transfer Switch Model # HTS15-AUTO

Contractors Guide Central Inverter System Installation

E2600 DSA E-Series iscsi Disk Arrays. en Quick Install Guide

Part Name/Description Part Number Quantity. Power Cable

MEDIUM FLAT PANEL DISPLAY STATIC MOUNT MSR Series

HP Carrier Grade Server cc3310 AC/DC Power Supply and DC Cable Installation. For the cc3310 Carrier Grade Server

Upgrading and Servicing Guide

OWNER'S MANUAL. Model CUL AC Power Inverter/Charger System OM/A96283 REV. A

OPL BASIC. Dosing System for Professional Laundry machines. Contents

RC001-4/RC002-4 (REV.B) 4-slot rack mounted chassis User manual

Distributing the Web server

VOT-320. VOT-320V0xxL VOT-320V0xxH. Quick Installation Guide

Canopy Surge. User Manual

Reliance DuraStar ORDINARY LOCATION INSTALLATION, OPERATING & MAINTENANCE INSTRUCTIONS

Full_IG.book Page 1 Monday, January 9, :11 PM. ProSafe 24 Port Gigabit Switch Installation Guide

CP2 Buried Cable Pedestal Initial & Rehab Installation Instructions

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

PXI -1000B AC POWER SUPPLY SHUTTLE

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules.

COMSPHERE 6700 SERIES NETWORK MANAGEMENT SYSTEM REMOTE MONITOR FEATURE

PEDAL POWER. User s Manual

Hard Disk Drive (HDD)

TS2 VRack. User and Installation Manual

Owner s Manual Ignition Upgrade Module for 2004-up Carbureted Harley Davidson Motorcycles P/N ASM5075

Installation. Basic Rack Power Distribution Unit for Blade Servers

EZ-Steer Assisted Steering System

12-Volt 10-Amp Regulated Power Supply

DTM04 TANK MONITOR DTM08 TANK MONITOR Dtm12 TANK MONITOR. Installation and Operation Manual

Battery Power Inverters

Cascade Profiler Fibre Channel SAN Attached Storage Installation Guide. Version 8.2 March 2009

DLP-PU/E Instruction Manual

Transcription:

Hotwire 8820 GranDSLAM AC to DC Power Supply Installation Instructions Document Number 8800-A2-GZ41-00 AC to DC Power Supply The AC to DC Power Supply consists of a power supply chassis and one or two power modules. The power supply chassis with one power module is Feature Number 8800-F2-900. The power module is Feature Number 8800-F2-901. The AC to DC Power Supply can be used to supply redundant power to a single Hotwire 8820 GranDSLAM, or non-redundant power to one or two GranDSLAMs. The maximum DC output of each power module is 825 watts. Do not exceed 825 watts in your GranDSLAM configuration. Product-Related Documents Document Number 8820-A2-GN20 Document Title Hotwire 8820 GranDSLAM Installation Guide Complete documentation for Hotwire products is available at www.paradyne.com. Select Library Technical Manuals Hotwire DSL & MVL Systems. To request a paper copy of a Paradyne document: Within the U.S.A., call 1-800-PARADYNE (1-800-727-2396) Outside the U.S.A., call 1-727-530-8623 8800-A2-GZ41-00 1

Installation Overview Installation of the AC to DC Power Supply requires the following steps: 1. Mount the power supply in your rack. 2. Connect the power supply to the Hotwire 8820 GranDSLAM. 3. Connect the power supply to an AC power source. Be sure to register your warranty at www.paradyne.com/warranty. Mounting the Power Supply Procedure To mount the power supply: 1. Remove the power modules from the power supply chassis. 2. The power supply is shipped with its mounting brackets set up for a 19-inch rack. If you are installing the power supply in a 23-inch rack, remove the mounting brackets from the power supply chassis, turn them, and reinstall them with their short sides against the body of the power supply chassis. 3. Determine where the power supply will be placed in the rack. The power supply should be placed under the GranDSLAM or GranDSLAMs it will supply power to. 4. If the rails of your rack have unthreaded screw holes, install self-retaining nuts on the rails where the mounting brackets will be fastened. 5. Line up the mounting brackets with the front rail holes. 6. Loosely install the bottom screws first and then the top screws. 7. Tighten all screws firmly with a Phillips screwdriver. 8. Replace the power modules removed in Step 1. 2 8800-A2-GZ41-00

POWER ENTRY MODULE LEFT UNIT: LINE A RIGHT UNIT: LINE B POWER ENTRY MODULE LEFT UNIT: LINE A RIGHT UNIT: LINE B WARNING! POWER MUST BE DISCONNECTED AT THE SOURCE WARNING! POWER MUST BE DISCONNECTED AT THE SOURCE BEFORE REMOVING OR INSTALLING THIS PWR ENTRY MODULE BEFORE REMOVING OR INSTALLING THIS PWR ENTRY MODULE CLOCK SERIAL AC A MCC ALARM B SERIAL ALARM CLOCK SMCM LAN/WAN SLOT A B Connecting the Power Supply to the GranDSLAM Power Entry Modules (PEMs) installed in the front of the GranDSLAM provide 48 VDC power distribution, a 35-amp circuit breaker, power line filtering and input power monitoring. They are designated PEM A (on the left) and PEM B (on the right). All input power is distributed to the system via the PEMs, so that if one PEM or one power source fails, power will be supplied through the other PEM automatically without service interruption. Power inputs may be connected to the PEMs at the front of the GranDSLAM using the PEM s terminal blocks, or at the terminal block on the back of the GranDSLAM. This document shows the recommended technique, with connections at the rear of the GranDSLAM. See the Hotwire 8820 GranDSLAM Installation Guide for more information. 48V 48V NEG 48V 48V NEG 2 4 6 8 10 12 14 16 18 1 3 5 7 9 11 13 15 17 PEM A PEM B PEM Circuit Breaker 48V POWER ENTRY MODULE LEFT UNIT: LINE A RIGHT UNIT: LINE B O 48V NEG WARNING! POWER MUST BE DISCONNECTED AT THE SOURCE BEFORE REMOVING OR INSTALLING THIS PWR ENTRY MODULE 00-15326a-02 Review the following procedures and determine which is appropriate for your configuration. The recommended configuration is two power modules connected to one GranDSLAM (providing a redundant power source). For all configurations: Make sure that the AC power cords are not connected to the power supply until other wiring is completed. Use 8 AWG solid or stranded wire. Attach ring tongue terminals to the ends of the wires to be connected to the GranDSLAM power terminal block. See the Hotwire 8820 GranDSLAM Installation Guide for more information. Attach ring tongue terminals to the ends of the wires to be connected to the power supply. Strip 1/2 inch of insulation from the ends of the wires to be fastened at split bolt connectors or the grounding lug of the GranDSLAM. CAUTION: The following procedures must be performed by a trained technician. 8800-A2-GZ41-00 3

Providing Redundant Power to One GranDSLAM (Recommended) Procedure To connect two power modules to one GranDSLAM (see Figure 1): 1. If none exist, install split bolt connectors or a grounding block near the rack where the power supply and GranDSLAM reside. 2. Connect: The grounding lug of the GranDSLAM to an earth ground. The PWR A 48V terminal of the GranDSLAM to the 48VA terminal of the power supply. The PWR A terminal of the GranDSLAM to a split bolt connector. The 0VRA terminal of the power supply to the split bolt connector. The PWR B 48V terminal of the GranDSLAM to the 48VB terminal of the power supply. The PWR B terminal of the GranDSLAM to a split bolt connector. The 0VRB terminal of the power supply to the split bolt connector. The split bolt connectors to an earth ground. 3. Verify that the power switches of the PEMs and the power modules are in the off (0) position. 4. Insert the AC power cords into the Input A and Input B sockets at the rear of the power supply. Plug the other ends into 115 VAC sources. 5. Turn to the On (1) position the power switches of PEM A and PEM B of the GranDSLAM and both power modules. Verify that the POWER LEDs at the front of the power modules and the POWER A and POWER B LEDs at the top of the GranDSLAM are on. 4 8800-A2-GZ41-00

Hotwire 8820 GranDSLAM Grounding Lug to Earth Ground CAUTION: USE NO. 8 AWG ONLY PWR B PWR A Split Bolt Connectors Earth Ground 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 B A 0VRB -48VB -48VA 0VRA AC to DC Power Supply 00-16717 Figure 1. One GranDSLAM Powered by Two Power Modules 8800-A2-GZ41-00 5

Providing Non-Redundant Power to One GranDSLAM Procedure To connect one power module to one GranDSLAM (see Figure 2): 1. If none exists, install a split bolt connector or grounding block near the rack where the power supply and GranDSLAM reside. 2. Connect: The grounding lug of the GranDSLAM to an earth ground. The PWR A 48V terminal of the GranDSLAM to the 48VA terminal of the power supply. The PWR A terminal of the GranDSLAM to the split bolt connector. The 0VRA terminal of the power supply to the split bolt connector. The split bolt connector to an earth ground. 3. Verify that the power switches of the PEMs and the power module are in the off (0) position. 4. Insert the AC power cord into the Input A socket at the rear of the power supply. Plug the other end into a 115 VAC source. 5. Turn to the On (1) position the power switches of PEM A and the power module. Verify that the POWER LED at the front of the power module and the POWER A LED at the top of the GranDSLAM are on. 6 8800-A2-GZ41-00

Hotwire 8820 GranDSLAM Grounding Lug to Earth Ground CAUTION: USE NO. 8 AWG ONLY PWR B PWR A Split Bolt Connector Earth Ground 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 B A 0VRB -48VB -48VA 0VRA AC to DC Power Supply 00-16715 Figure 2. One GranDSLAM Powered by One Power Module 8800-A2-GZ41-00 7

Providing Non-Redundant Power to Two GranDSLAMs Procedure To connect two power modules to two GranDSLAMs (see Figure 3): 1. If none exist, install split bolt connectors or a grounding block near the rack where the power supply and GranDSLAMs reside. 2. Connect: The grounding lugs of the GranDSLAMs to an earth ground. The PWR A 48V terminal of the first GranDSLAM to the 48VA terminal of the power supply. The PWR A terminal of the first GranDSLAM to a split bolt connector. The 0VRA terminal of the power supply to the split bolt connector. The PWR A 48V terminal of the second GranDSLAM to the 48VB terminal of the power supply. The PWR A terminal of the second GranDSLAM to a split bolt connector. The 0VRB terminal of the power supply to the split bolt connector. The split bolt connectors to an earth ground. 3. Verify that the power switches of the PEMs and the power modules are in the off (0) position. 4. Insert the AC power cords into the Input A and Input B sockets at the rear of the power supply. Plug the other ends into 115 VAC sources. 5. Turn to the On (1) position the power switches of PEM A of each GranDSLAM and both power modules. Verify that the POWER LEDs at the front of the power modules and the POWER A LEDs at the top of the GranDSLAMs are on. 8 8800-A2-GZ41-00

Hotwire 8820 GranDSLAM CAUTION: USE NO. 8 AWG ONLY PWR B PWR A Grounding Lug to Earth Ground CAUTION: USE NO. 8 AWG ONLY PWR B PWR A Split Bolt Connectors Earth Ground 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 B A 0VRB -48VB -48VA 0VRA AC to DC Power Supply 00-16716 Figure 3. Two GranDSLAMs Powered by Two Power Modules 8800-A2-GZ41-00 9

Warranty, Sales, Service, and Training Information Contact your local sales representative, service representative, or distributor directly for any help needed. For additional information concerning warranty, sales, service, repair, installation, documentation, training, distributor locations, or Paradyne worldwide office locations, use one of the following methods: Internet: Visit the Paradyne World Wide Web site at www.paradyne.com. (Be sure to register your warranty at www.paradyne.com/warranty.) Telephone: Call our automated system to receive current information by fax or to speak with a company representative. Within the U.S.A., call 1-800-870-2221 Outside the U.S.A., call 1-727-530-2340 Document Feedback We welcome your comments and suggestions about this document. Please mail them to Technical Publications, Paradyne Corporation, 8545 126th Ave. N., Largo, FL 33773, or send e-mail to userdoc@paradyne.com. Include the number and title of this document in your correspondence. Please include your name and phone number if you are willing to provide additional clarification. Trademarks Hotwire is a registered trademark of Paradyne Corporation. All other products and services mentioned herein are the trademarks, service marks, registered trademarks, or registered service marks of their respective owners. *8800 A2 GZ41 00* Copyright 2000 Paradyne Corporation. Printed in U.S.A. 10 8800-A2-GZ41-00