Powerformer chosen for Swedish combined heat and power plant



Similar documents
Generators TEM. for small hydroelectric power stations. Electric Machines

Electric Power Systems An Overview. Y. Baghzouz Professor of Electrical Engineering University of Nevada, Las Vegas

Offshore Platform Powered With New Electrical Motor Drive System

Power Plant Electrical Distribution Systems

The stable way. Synchronous condenser solutions. siemens.com/energy/facts

Bioenergy. A sustainable energy source.

Good Practice Form

Basics of Electricity

Turbo generators Best quality for thermal power plants

Power transformers. Generator step-up and system intertie power transformers Securing high-quality AC transmission

BIOPOWER 5 CEX. 1 Wärtsilä 10 January 2012 Presentation name / Author

*ADVANCED ELECTRIC GENERATOR & CONTROL FOR HIGH SPEED MICRO/MINI TURBINE BASED POWER SYSTEMS

SYNCHRONOUS MACHINES

Mechanical and electrical rebuilding of a turbine generator for phase-shift operation

University of Maryland College Park District Energy System. IDEA Campus Energy Conference February 9, 2012

L.I. Chubraeva. Corr. Member of RAS

Södra Näs Vimmerby Energi AB Biomass District Heating Plant, Sweden

S Y N C H R O N O U S G E N E R A T O R S

water is cooled in a secondary cooling control tasks: use of seawater. Treatment of the seawater formation of algal vegetation.

Product brochure Multi Functional Switchgear PASS M kv Flexible and compact switchgear solutions for windfarms

Relion. Power system protection and automation reference Fast substation busbar protection with IEC and GOOSE

Transformer Design & Design Parameters

ORC TURBOGENERATOR TYPE CHP - Organic Rankine Cycle Turbogenerator fed by thermal oil, for the combined production of electric energy and heat -

100% Stator Ground Fault Detection Implementation at Hibbard Renewable Energy Center. 598 N. Buth Rd 3215 Arrowhead Rd

Generator Stator Protection, under/over voltage, under /over frequency and unbalanced loading. Ramandeep Kaur Aujla S.NO

Wound Rotor Induction Motors 4-12 poles, up to 8000 kw, HP

525-MVA Generator-motor and Thyristor Starter Put into Service at the Tokyo Electric Power Co., Inc. s Kannagawa Hydroelectric Power Station

Brochure. Electric generators to power the world

Integrating renewable energy sources and thermal storage

Paralleling Power Sources Which Share a Common Neutral

GE Power Conversion. Generators. 2,500 to 80,000 kva Up to 22,000 Volts

Case Study 5 Use of Wind Turbine Technology

WIND TURBINE TECHNOLOGY

CONTINUOUS AUTOMATED FLUX MONITORING FOR TURBINE GENERATOR ROTOR CONDITION ASSESSMENT

Synchronous generators are built in large units, their rating ranging from tens to hundreds of megawatts.

The following table shows approximate percentage wise the

Design and Test Operation Performance of 1,500 C Class Gas Turbine Combined-Cycle Power Plant:

Service Life of Stator Winding Insulation as an Important Quality Feature of Large Hydro Generators

How To Power A Power Plant With Waste Heat

3. Three phase winding technology

Design of electrical power system for a 1000MW nuclear power generating station

Respecting the environment

2. A conductor of length 2m moves at 4m/s at 30 to a uniform magnetic field of 0.1T. Which one of the following gives the e.m.f. generated?

Power Island. Industrial Power Plants. / energy

Unified requirements for systems with voltages above 1 kv up to 15 kv

Calculation of Temperature in a Large Turbine Generator with Multilayer Roebel Transposition Coils

Selecting Current Transformers Part 1 By Darrell G. Broussard, P.E.

DC GENERATOR THEORY. LIST the three conditions necessary to induce a voltage into a conductor.

Cahier technique no. 196

Top Technology for Industry, Agriculture, Business and Communities

Principles of Adjustable Frequency Drives

Reducing Maintenance Costs Replacement of Small Fossil Generators in Russia

Boilers and cogeneration/trigeneration. Abhi Sawant Business Development Manager Simons Green Energy

POWER SYSTEM CONSULTANTS POWER-LINKER

BIOMASS LOOKING FOR EFFICIENT UTILIZATION THE REHEAT CONCEPT. Jaroslav Lahoda Olaf Arndt Walter Hanstein. Siemens Power Generation (PG)

HVDC Light, a tool for electric power transmission to distant loads

Replacement Generators to Modernize and Uprate Power Trains Limited by the Generator

Source: EIA Natural Gas Issues and Trends 1998

Guideline for Energy Efficient Electrical systems for building. Presentation by TERI

Turbine Generator Sets 101 Skinner Power Systems LLC September 2006 Rev 1 May 2009

Current state of plant Functioning as a peak and emergency centre. Statistics Accumulated operating hours:

Appendix N: GENERATOR DATA SHEET FOR SYNCHRONOUS GENERATORS CONNECTED TO PG&E ELECTRIC SYSTEM

Request for Payment Instructions Wholesale Distribution Access Tariff (WDAT) Attachment I - GIP

Three-phase AC circuits

LIMITING SHORT-CIRCUIT CURRENTS IN MEDIUM-VOLTAGE APPLICATIONS

Fundamentals of Modern Electrical Substations Part 1: Mission of Electrical Substations and their Main Components

Controlled subsea electric power distribution with SEPDIS

Energy Efficiency in Steam Systems

Little Barford Power Station Visit Report

SYNCHRONOUS MACHINE TESTING WITH MOTOR CIRCUIT ANALYSIS INSTRUMENTATION

Power transformers. Special transformers Railway

HVDC 2000 a new generation of high-voltage DC converter stations

This document contains information proprietary to Mitsubishi Electric Corporation. It is submitted in confidence and is to be used solely for the

HVDC Technology for Large Scale Offshore Wind Connections

Performance Analysis of Thermal Power Station: Case Study of Egbin Power Station, Nigeria

Module 1. Introduction. Version 2 EE IIT, Kharagpur

Tour of new eircom Data Centre Blanchardstown by Dervan Engineering Consultants 11 th March 2015

Efficiency Metrics for CHP Systems: Total System and Effective Electric Efficiencies

BASIC AC ELECTRICAL GENERATORS

Siemens D3 platform 3.0-MW, 3.2-MW, 3.3-MW, and 3.4-MW direct drive turbines. Reduced complexity, increased profitability. siemens.

Stora Enso Fors Ltd Sweden

Brochure. Generators for wind power Proven generators reliable power

EFFICIENT ELECTRICAL ENERGY TRANSMISSION AND DISTRIBUTION INTERNATIONAL ELECTROTECHNICAL COMMISSION

Comparative study for cables and busbars

AC Induction Motor Slip What It Is And How To Minimize It

Smart solutions for fleets of all types & sizes of power generation. Marcus König, E F IE SGS / September 2013

Mission 4: Fossil Fuel Power Stations

Three-Phase Electric Power Distribution for Computer Data Centers

ELECTRICAL ENGINEERING DESIGN CRITERIA APPENDIX F

SIMULATING HYBRID ENERGY GRIDS IN SMART CITIES FOCUS ON ELECTRIC ENERGY SYSTEMS

2013 RESIBLOC transformers Product presentation. ABB Group October 2, 2013 Slide 1

Variable Frequency Drives - a Comparison of VSI versus LCI Systems

PI734D - Technical Data Sheet

300 MW Variable Speed Drives for Pump-Storage Plant Application Goldisthal

Large Generators and High Power Drives

PI734B - Technical Data Sheet

Excitation.

Energy transfers. Coal is mined and transported to the power station. It is ground into a powder to make it burn quicker. Step 2:

MOHAMMAD KHORAMI. Examiner: Dr. Anh Tuan Le Senior Lecturer, Electric Power Engineering, Chalmers University of Technology. Master of Science Thesis

Transcription:

Powerformer chosen for Swedish combined heat and power plant Powerformer, a radically new type of generator developed by ABB, has been chosen for a combined heat and power plant in Eskilstuna, Sweden. This first commercial order for Powerformer from the thermal power sector is for a generator rated at 4 MVA, 136 kv and 3000 rev/min. It will be connected directly to existing 136-kV switchgear, ie no step-up transformer will be used. The life-cycle cost of Powerformer is expected to be 1 percent lower than for a conventional generator. A fter evaluating a life-cycle cost analysis which compared the overall economy of a conventional plant with that of a plant based on Powerformer generator technology, Swedish municipal utility Eskilstuna Energi & Miljö AB chose Powerformer for its new combined heat and power (CHP) station. The plant is being built next to an existing district heating power station in the city of Eskilstuna, some 100 km west of Stockholm. It is due to enter service in the year 000 and is expected to operate for approximately,000 hours a year 1. The Eskilstuna CHP project The new CHP plant at Eskilstuna will have an electrical rating of 38 MW and produce 71 MW of heat, plus another 1 MW of heat that will be recovered from the flue gases. Biomass, mainly forest and sawmill waste, will be used as fuel. Steam from the boiler, which is rated at 110 MW, will be fed to a steam turbine supplied by ABB Stal AB, Sweden. The turbine is a two-casing type, with a high-pressure and a low-pressure module. Powerformer, which is built by ABB Generation AB of Sweden, will be driven from both ends by the two steam turbine modules. Among the reasons for the utility choosing Powerformer were the high overall efficiency and the simplicity of the power plant configuration that the innovative concept makes possible. Both of these factors will favourably influence the life-cycle costs of the Eskilstuna CHP Lars Andersson Eskilstuna Energi & Miljö AB Mats Kjellberg Christer Parkegren Torbjörn Sörqvist Annika Karlsson Kåre Gundersen ABB Generation AB Powerformer a radically new generator Powerformer employs a completely new generator technology to produce electric power at the high-voltage level. With Powerformer, it is not necessary to transform to a higher voltage level as in the case of conventional generators. By eliminating the step-up transformer, the electrical efficiency of the power plant is 0. to.0 percentage points higher than with traditional plants. Powerformer revolutionizes the established, traditional generator technology and represents a genuine milestone in the history of electrical engineering [1]. At first glance, Powerformer looks like a conventional air-cooled turbogenerator 3. In fact, it essentially uses proven technology, with features that include: Air-cooled cylindrical -pole rotor Brushless exciter Pedestal bearings Laminated stator core Cylindrical stator frame HV cables act as stator winding In Powerformer, high-voltage cables with XLPE insulation replace the complex structure of square, insulated copper conductors that form the stator winding of a conventional generator. High-voltage cables with XLPE insulation are available today for voltages of up to 400 kv. When XLPE-insulated cables were introduced in the 1960s there were some initial problems with their reliability, caused by poor control of the manufacturing processes. These problems have since been overcome, and today s highvoltage XLPE-insulated cables have an impressive track record. A comparison of the number of faults in conventional generator windings with the number in highvoltage XLPE-insulated cables shows that the cables have fewer faults. ABB Review 3/1999 19

Artist s impression of the Eskilstuna combined heat and power plant 1 Process diagram of the Eskilstuna CHP plant 1 Boiler District heating condensers High-pressure steam turbine 6 Low-pressure preheater 3 Low-pressure steam turbine 7 Deaerator 4 Powerformer (high-voltage generator) 8 High-pressure preheater 1 8 7 4 6 3 The use of HV cables offers some important advantages. Firstly, the circular conductor geometry allows an evenly distributed electric field. This means that the insulation material is stressed uniformly. Secondly, the cable is designed for an electrical field stress of 10 kv/mm, a much higher figure than the 3 kv/mm that modern-day generator windings can manage. The combination of these two factors allows a dramatic increase in the generated voltage. The use of high-voltage cables also ensures full insulation of the generator winding. With this arrangement the risk of partial discharge as well as internal two- and three-phase faults is minimized. The stator current is considerably lower than with conventional generators on account of the higher generated voltage. The 0 ABB Review 3/1999

Powerformer generator rated 136 kv for the Eskilstuna combined heat and power plant 3 low current means that the mechanical forces acting on the end winding will also be low. As a result, the bracing system for the end winding can be made simpler than in the case of a conventional generator. Cooling system Powerformer has two cooling systems, both of them conventional and of proven design. The rotor and coil-ends are aircooled by a closed ventilation system which uses air/water coolers to re-cool the air. The stator core is water-cooled by cooling-water pipes running axially in the core. Normal-quality cooling water can be used as the water remains at zero potential. Losses and reactances The losses in Powerformer are of the same order of magnitude as those in a traditional generator. However, they are distributed differently. Copper losses, stray losses and ventilation losses are lower, whereas iron losses are higher. The efficiency of Powerformer normally lies in the range of 97. to 98. %; for the Eskilstuna combined CHP plant the figure is 98. % (Table 1). Powerformer can be designed with reactances of the same order of magnitude Table 1 Powerformer for Eskilstuna CHP plant: technical data as a traditional generator/step-up transformer configuration. The short-circuit currents in the high-voltage switchgear are therefore also of the same order of magnitude. Reduced environmental impact Another important benefit of Powerformer is that its high efficiency reduces the envi- Output MVA 4 Power factor 0.93 Voltage kv 136 Speed rev/min 3000 Frequency Hz 0 Cooling rotor IC8A1W7 (air) end winding IC8A1W7 (air) stator core IC9W7W7 (water) Efficiency 98. % ABB Review 3/1999 1

Table Life-cycle cost analysis for the Eskilstuna CHP plant ronmental impact of the power Also, Powerformer contains fewer environmentally hazardous substances. For instance, no epoxy resin is used; this is in stark contrast to conventional generators, in which it is used to impregnate the stator coils. As no step-up transformer is needed with Powerformer, the problems previously posed by the several tonnes of oil in the transformer tank are eliminated. The same applies to the oil-based insulation and cooling systems, which have been potential hazards in the past due to the risk of fire and oil leakage. Plant based on Conventional plant Powerformer (%) (%) Investments Powerformer, 136 kv 100 Generator, 11 kv 44 Generator busbars and switchgear, 11 kv 7 Transformer, 11/136 kv 6 Transformer building Operation and maintenance Efficiency, 400 kwe lower output Availability, 0 hours lower pa 11 Maintenance Reactive power Environmental impact Total 100 11 Conditions: interest rate 6% operating hours 000 pa life-cycle 0 years loss evaluation USD /MWh Other factors are the reduced electric and magnetic fields, which provide for a safer working environment in the Simplified and more efficient electrical package Table 3 Powerformer for thermal power (output range 0 00 MW) Output MW 0 00 Voltage kv 0 Speed rev/min 3000/3600 Frequency Hz 0/60 Drive Steam turbine/gas turbine Single-end drive/double-end drive Fewer components The generator terminals are connected via high-voltage cables directly to the 136-kV switchgear situated some 1.3 km from the CHP A 136-kV circuitbreaker takes over the function of the traditional generator breaker, with some very important advantages for the utility 4 : No 11-kV busbar is required. 11-kV generator switchgear is not required. No 11/136-kV step-up transformer is required. A number of smaller components, eg current transformers, voltage transformers and surge arresters, are also eliminated. As a result, the Eskilstuna CHP plant will be considerably simpler than a conventional Powerformer has all the usual protection features, such as surge protection, generator protection and cable protection. For grounding, Powerformer utilizes the system grounding in the 136-kV switchgear. The generator neutral has a surge arrester for overvoltage protection. Due to its fewer components, the Eskilstuna plant is also expected to require less maintenance. Improved efficiency and reliability By eliminating the generator busbars, generator switchgear and step-up transformer, losses are reduced by approximately 400 kw. Without these components, availability at the Eskilstuna plant is expected to be higher than in a conventional plant by about 0 hours per year. Not only the active losses are reduced. A step-up transformer also consumes reactive power; since the step-up transformer, and therefore its reactive power losses, are eliminated, there is more reactive power available for the grid and to meet internal reactive power demand. A higher efficiency has two other major benefits. More electric power can be pro- ABB Review 3/1999

duced for the same fuel input or the same amount of electrical power can be produced using less fuel. Either way there are both commercial and environmental advantages. 3 136kV 136kV 4 4 9 1 percent lower life-cycle cost Powerformer was developed in response to the power industry s drive to achieve more efficient operation and maintenance for generation Powerformer offers advantages in technical performance that can be translated into economic benefits. Eskilstuna Energi & Miljö selected Powerformer technology on account of its ability to generate cost-effective and environmentally friendly electric power. The utility estimates that its investment will be paid back within 7 to 10 years. An analysis carried out by the utility, showed the life-cycle cost for a plant based on Powerformer technology to be 1 % lower than for a conventional plant (Table ). This analysis took into account the investment cost, revenues and cost of operating the plant, interest rate, etc. a 1 The electrical package Powerformer (a) versus a conventional design (b) 11kV 1 Powerformer (high-voltage generator) Conventional 11-kV generator 136-kV cable (1.3 km) 6 11-kV generator breaker 3 136-kV breaker 7 11-kV busbar (acting as generator breaker) 8 11/136-kV step-up transformer 4 136-kV busbar 9 136-kV breaker b 6 8 7 4 Powerformer now available for 0 to 00 MW The key feature of Powerformer technology is the use of high-voltage cables instead of a conventional stator winding. This technology can be utilized basically in every kind of rotating electrical machine. ABB is developing the Powerformer concept for different applications, and at the present time it can be supplied for hydropower and thermal power generation plants. For thermal power applications, Powerformer is currently available in the output range of 0 00 MW and with voltages of 0 kv (Table 3). Development is continuing with the goal of increasing both the output and voltage. Reference [1] M. Leijon: Powerformer a radically new rotating machine. ABB Review /98, 1 6. Authors Lars Andersson Eskilstuna Energi & Miljö AB Mats Kjellberg Christer Parkegren Torbjörn Sörqvist Annika Karlsson Kåre Gundersen ABB Generation AB S-71 76 Västerås Sweden Telefax: +46 1 41 9 77 E-mail: mats.kjellberg@segen.mail.abb.com ABB Review 3/1999 3