Picture 1 Lead Color Code Lead Function V-Link Function V-Link Pin Table 2 Picture 2 Node Commander software



Similar documents
Experiment 5. Strain Gage Measurements

Subminiature Load Cell Model 8417

Precision Miniature Load Cell. Models 8431, 8432 with Overload Protection

Environmental Monitoring with Sensors: Hands-on Exercise

The SOLUTION for Gathering Rotary Torque Sensor with Encoder Data

Mobile Device Power Monitor Battery Connection Quick Start Guide

QUICK START GUIDE FOR DEMONSTRATION CIRCUIT BIT DIFFERENTIAL ADC WITH I2C LTC2485 DESCRIPTION

PUSH BUTTON START INSTALLATION MANUAL

Digital Pressure Measuring Instrument MDR480

Operating instructions Diffuse reflection sensor. OJ50xx / / 2004

PMP 4000 Series. Druck Amplified Output Pressure Transducers. GE Sensing. Applications. Features

I Click on a link tab to jump to that page. Cover Page

9. Force Measurement with a Strain gage Bridge

G-100/200 Operation & Installation

DSTV DECODER SETUP MANUAL July 2013

OEM Manual MODEL 2350 ELECTRONIC DUAL CYLINDER SCALE

Dynamax Inc Copyright

SMS Alarm Messenger. Setup Software Guide. SMSPro_Setup. Revision [Version 2.2]

TDAS G5-DB Hardware User s Manual

Weight Measurement Technology

DPI 260 SERIES: Digital Pressure Indicators

I Click on a link tab to jump to that page. Cover Page

CoolWave r 2 Phase Control Board and Cable Replacement Kits

6703/6704 ANALOG OUTPUT DEVICE CALIBRATION PROCEDURE

Characterizing Digital Cameras with the Photon Transfer Curve

Fitting/Installation Guide - UNIVERSAL

Transmitter Interface Program

ABB Drives. User s Manual HTL Encoder Interface FEN-31

WEB log. Device connection plans

Signal Conditioning Wheatstone Resistive Bridge Sensors

GLOLAB Universal Telephone Hold

RC Camera Control. User Guide v /20/2012

i ChatterBox! Motorcycle Security

Universal Vehicle Power Supply 9007AX01. Installation Instructions

Digital I/O: OUTPUT: Basic, Count, Count+, Smart+

Cover Page. Factory Radio Other Documents Available For This Vehicle:

Model 201 Wiegand Touchpad Reader Installation Guide

MoTeC USA GPS. Part # M GPS BL Available in 10 Hz or 20 Hz. USER MANUAL Version 1.4

PRODUCTIVITY THROUGH INNOVATION 600 CONTROL DIRECT DRIVE TECHNICAL/OPERATION MANUAL

K-Type Thermocouple Sensor User s Guide

Troubleshooting and Diagnostics

The $25 Son of a cheap timer This is not suitable for a beginner. You must have soldering skills in order to build this kit.

Control Box Wiring For PRSstandard Tool

PART 1 - INTRODUCTION...

THERMAL ANEMOMETRY ELECTRONICS, SOFTWARE AND ACCESSORIES

FUTEK USB LabVIEW 11 Example

RECOMMENDED TOOLS PERSONAL & VEHICLE PROTECTION SAFETY GLASSES

TS1 Ultra Sonic Tank Sender Training. 27 November 2007

ViZion Installation Guide

An Overview of Calibration Methods and Procedures for Process and Inventory Weigh Systems

How to connect to a Class II router using a mobile-phone data cable specifically for Solwise & Safecom routers

EMBEDDED ACCESS CONTROL Hardware Installation Guide

Model DFG-RSA Configurable Load Cell Adapter

GENERAL SCIENCE LABORATORY 1110L Lab Experiment 6: Ohm s Law

FUTURELIGHT RDM PC DIRECTOR

Alpy calibration User Guide. Olivier Thizy François Cochard

ATL Fuel Level Sender Probes

OEM-EP Pressure Controllers

10/ English Edition 1. Quick Start Guide. NWA1100N-CE CloudEnabled Business N Wireless Access Point

Note monitors controlled by analog signals CRT monitors are controlled by analog voltage. i. e. the level of analog signal delivered through the

The Do s and Don ts of Pressure Transducers

Wireless LAN g USB Adapter

Mini Effect Gizmo. User s Manual. RJM Music Technology, Inc.

Cell Phone Vibration Experiment

G3 Series PROFIBUS DP Technical Manual

Installation. Powerline 500 Model XAVB5221

Quick Start Guide , Rev DA March Rosemount 8714D (Calibration Standard) Magnetic Flowtube Simulator

Parts List. Navigation

INDEX. Trademarks All name and product s trademarks mentioned below are the property of their respective companies.

Mini Amp Gizmo. User s Manual. RJM Music Technology, Inc.

Automation and Systems Technology. LABCONTROL TFM/TPM User Manual TroxMConnect Operating Software. 1. Introduction Software Installation 2

Digital Air Pressure Gauge Users Manual

Electrical Resonance

Introduction. Drenth Motorsport Gearboxes Fleuweweg AG Enter The Netherlands Phone: +31 (0) Fax: +31 (0)

Cornerstone Electronics Technology and Robotics I Week 15 Voltage Comparators Tutorial

DAC Digital To Analog Converter

Lab 4 - Data Acquisition

RS232/DB9 An RS232 to TTL Level Converter

INSTALLATION AND OPERATION MANUAL

Applied Electronics. Commercial Dimming System UPDATE NOTICE

* DISCLAIMER: Contents. How to Use This Guide: COMMERCIAL INSTALL GUIDE 2

Lighting Controls ! WARNING RISK OF ELECTRIC SHOCK. Installation Instructions DESCRIPTION

Allegion PIM-400/485 and AD-400 Installation Application Note. 1.0 Hardware Requirements. 2.0 Software/Licensing Requirements

Draper Low Voltage, Remote Control, Serial and Network Wiring Guide

Lab 3 - DC Circuits and Ohm s Law

WxGoos-1 Climate Monitor Installation Instructions Page 1. Connections. Setting an IP Address

MGL Avionics CAN bus interface for Trig Avionics TT21/TT22 transponders

Termination Resistors:

BROOKFIELD MODEL VTE250 ELECTRIC VISCOSEL PROCESS VISCOMETER. Installation, Operation, and Maintenance Instructions. Manual No.

Six-servo Robot Arm. DAGU Hi-Tech Electronic Co., LTD Six-servo Robot Arm

Calibration with bridge measurements

The Wireless LAN (Local Area Network) USB adapter can be operated in one of the two following networking configurations :

Dash 18X / Dash 18 Data Acquisition Recorder

OPERATION MANUAL VALVE CHECKER G

LAB2 Resistors, Simple Resistive Circuits in Series and Parallel Objective:

LCWM Glossary. Mettler Toledo LCWM Glossary

IMMS-CCC. IMMS-CCC Hardwire Central Interface. Installation Instructions

Modifying the Yaesu FT-847 External MHz Reference Input

Series and Parallel Resistive Circuits Physics Lab VIII

Section 3. Sensor to ADC Design Example

Transcription:

TN-W0026 MicroStrain Technical Note Connecting and Calibrating a Load Cell with V-Link V-Link and Futek LSB300 Load Cell (Applies to V-Link, SG-Link, SG-Link OEM, HS-Link ) Overview MicroStrain s V-Link Wireless Voltage Node has 4 differential input channels (strain channels) designed to support strain gauges, load cells, etc. Futek s LSB300 Series is an S Beam Load Cell designed for use in platforms, silos and scales; for purposes of this discussion, we are using the 200 lbs capacity, full bridge model FSH02077. This technical note presents a step-by-step approach to connecting the load cell to the V-Link, calibrating the load cell, and operating the system. It is assumed that the user is familiar with MicroStrain s V-Link and Node Commander software as well as load cell operation. Wiring Connection The Futek load cell presents a 5 foot, polyurethane sheathed, shielded, connection cable with 6 flying leads. Table 1 describes the individual leads purpose and nomenclature: 1 Red +EXC +Excitation 2 Black -EXC -Excitation 3 Green +SIG +Signal 4 White -SIG -Signal 5 Orange +SEN +Sense 6 Blue -SEN -Sense Shield Silver Grounded Shield Table 1 To connect to the V-Link, we need only deal with the Red, Black, Green, and White leads. Cut back the Orange and Blue leads and secure them to prevent shorting. Strip back each of the 4 remaining leads approximately ½. Tin (with solder) each of the 4 leads to insure a good grip in the V-Link s terminal block connector. It is also strongly recommended that you solder the shielding of the cable to the Black lead as shown in Picture 1. This will reduce noise in the system. 1

Picture 1 Connect the 4 leads of the load cell to the V-Link as shown in Table 2 and Picture 2. For this example we are connecting to differential input channel 1 of the V-Link. Lead Color Code Lead Function V-Link Function V-Link Pin Red +Excitation Sensor Power Out 16 Black -Excitation Ground 17 Green +Signal Sensor 1-15 White -Signal Sensor 1+ 13 Table 2 Picture 2 Node Commander software Power-up the V-Link and launch Node Commander software. Establish communication with the V-Link as normal. Proceed to the Configuration screen and enable the channel to which you connected the load cell (channel 1 in this case). Continue to the Channel 1 Configuration screen. 2

Select the Midscale bullet under the Auto-Balance button. Click the Auto-Balance button. A pop-up window will appear similar to the example shown in Picture 3. Picture 3 The key information within the window is the 2040 bits and the 513 offset. We are looking for a value of approximately 2048 (+/- 50) bits. This is mid-scale on the V-Link s 0 4096 bit measurement range. Low-scale balancing will yield approximately 1024 bits; high-scale will be approximately 3072 bits. You should use mid-scale balancing if you are expecting equal amounts of positive and negative output from the load cell. Low-scale is used if you are expecting more positive and high-scale if more negative data. The offset is used to get the measurement range to align with the expected load cell output. The value for mid-scale should be approximately 512 (+/- 10) for a balanced bridge situation. If these numbers are off, the wiring of the load cell to the V-Link is likely not sound. Correct the wiring and re-run the auto-balancing to verify. Click OK to close the pop-up window. Click OK to close the Channel 1 Configuration screen. Click Apply and click OK to close the Configuration screen and return to main screen of Node Commander. Stream the node and exercise the load cell by hand to check you are getting proper output as shown in Picture 4. Picture 4 3

If the data is opposite to what you would expect, i.e., it goes negative when you were expecting positive, switch the Green and White leads to the V-Link. Now re-run the auto-balance procedure and stream to verify proper operation. Calibrations We actually have several options to calibrate the load cell with the V-Link : The poor man calibration Hang several weights off the load cell and read the output of the V-Link. A limiting factor for this option is the number and accuracy of the weights available. Use the factory calibration of the load cell. Futek calibrates the load cell and provides a sensitivity coefficient that allows us to calculate a slope and offset. A limiting factor for this option is that the factory calibration does not take into account the load cell connections to the V-Link or the V-Link electronics. Utilize a calibrated tensometer to apply at least ten loads over the entire range of the load cell. Not everyone has a large expensive testing apparatus, but this will give the most accurate results. Poor man calibration Securely hang the load cell to a sturdy structure that will support the weights you apply to the load cell, as shown in Picture 5. Picture 5 Launch Node Commander software. Establish communication with the V-Link as normal. Proceed to the Configuration screen. Continue to the Channel 1 Configuration screen. Select A/D Value under Class and Bits under Units in the Conversion Class frame as shown in Picture 6. 4

Click OK to close the Channel 1 Configuration screen. Picture 6 Proceed by streaming the node and observing the bit output using various weights. In our example shown in Picture 7, we are demonstrating four weights, i.e., 0 (no weight), 5 lbs, 10 lbs and 25 lbs. After making weight measurements, calculate a slope from the data using the formula y=mx+b. Please see our technical note for a step-by-step using Microsoft Excel. Bits Lbs 2033 0 2069 5 2108 10 2213 25 Picture 7 In our example we see a slope of 0.1389 and an offset of -282.55. Return to the Channel 1 Configuration screen. Select Force under Class and Lbf under Units in the Conversion Class frame as shown in Picture 8. Click the Modify button and enter 0.1389 in Slope and -282.55 in Offset. Click Lock to apply the Slope and Offset. Click OK to close the Channel 1 Configuration screen. 5

Picture 8 Proceed to again stream the node with no weight on the load cell. Observe the value in the stream graph. If the stream is not at zero, return to the Channel 1 Configuration screen. Modify the Offset by increasing or decreasing the value to zero the output. Hang different weights on the load cell to verify calibration throughout its range. Using Factory Calibration of Load Cell The load cell in this example has been calibrated at the factory in the tension direction. It has a calibration sheet indicating an output sensitivity of 1.7777 mv/v @ 200 Lbs. With this information we can calculate the slope as follows: o 1.7777 mv/v x 3 V(excitation voltage) = 5.3331 mv for full range of 200 Lbs o 5.3331 mv x 210 (user selectable gain) = 1.119951 V o 1.119951 V / (3 V/4096 Bits) (see note) = 1529.987704 Bits o 200 Lbs / 1529.987704 Bits = 0.130720 (slope) Note: The V-Link has a 12-bit A/D converter with a 3 volt excitation, resulting in 4096 Bits / 3 Volts = 0.000732 Bits/Volt. Return to the Channel 1 Configuration screen. Select Force under Class and Lbf under Units in the Conversion Class frame. Click the Modify button and enter 0.130720 in Slope and 0 in Offset. Click Lock to apply the Slope and Offset. Click OK to close the Channel 1 Configuration screen. Stream the node with no weight on the load cell. Observe the value in the stream graph. If the stream is not at zero, return to the Channel 1 Configuration screen. Modify the Offset by increasing or decreasing the value to zero the output. Hang different weights on the load cell to verify calibration throughout its range. 6

Using a Calibrated Tensometer The procedure is very similar to the poor man calibration. Instead of hanging weights from the load cell, we are mounting the load cell into the tensometer as shown in Picture 9, applying precision loads, and noting the corresponding bit values. Picture 9 Proceed by streaming the node and observing the bit output using various weights. In our example shown in Picture 10, we are demonstrating 11 loads, i.e., 0 (no load), 21 lbs, 39 lbs, and so forth. After making weight measurements, calculate a slope from the data using the formula y=mx+b. Please see our technical note for a step-by-step using Microsoft Excel. Bits Lbs 2036 0 2191 21 2324 39 2475 61 2617 80 2760 100 2908 120 3056 141 3201 161 3348 181 3495 200 Picture 10 7

In our example we see a slope of 0.1378 and an offset of -280.64. Return to the Channel 1 Configuration screen. Select Force under Class and Lbf under Units in the Conversion Class frame. Click the Modify button and enter 0.1378 in Slope and -280.64 in Offset. Click Lock to apply the Slope and Offset. Click OK to close the Channel 1 Configuration screen. Proceed to again stream the node with no load on the load cell. Observe the value in the stream graph. If the stream is not at zero, return to the Channel 1 Configuration screen. Modify the Offset by increasing or decreasing the value to zero the output. Apply different loads on the load cell to verify calibration throughout its range. Note: You should apply at least ten loads (even more is better) over the entire range of the load cell rating to increase the accuracy of the calibration. Support MicroStrain support engineers are always available to expand on this subject and support you in any way we can. MicroStrain, Inc. 459 Hurricane Lane, Unit 102 ph: 800-449-3878 Rev 1.1 Williston, VT 05495 USA fax: 802-863-4093 Copyright 2012 MicroStrain, Inc. www.microstrain.com support@microstrain.com MicroStrain and V-Link are registered trademarks of MicroStrain, Inc. 8