Installation Manual. Features SMART SWITCH OCCUPANCY SENSOR. Maximum Energy savings



Similar documents
LOS 2500 SUPER CEILING SENSOR. Installation Manual

MOTION SENSOR PIR LIGHT SWITCH INSTALLATION & OPERATING. Cat No. ZV810 INSTRUCTIONS

Die-Cast Metal, Motion- Activated Post Light

Installation Instructions

LED MOTION ACTIVATED FLOOD LIGHT

Motion Detector 360 Degrees 5420/360. Installation Instructions REGISTERED DESIGN REGISTERED PATENT

Installation Manual. The STEALTH 360 is the most reliable and technically advanced motionactivated

LED Security Spotlight User Manual

PGL5/6 - Parking Garage Luminaire Installation Instructions

5W LED Energy Saver PIR Bulkhead

Dual Technology Ceiling Mount Sensor

Passive Infrared Motion Detector 5420/90. Installation Instructions

60W PIR BULKHEAD LIGHT SLB88-Black/SLW89-White INSTALLATION & OPERATING INSTRUCTIONS

Table of Contents. What to Expect with. Preparation. Tools Needed. Wiring. Hanging the Fan. Blades. Motor Housing.

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W

ISL-540 TBTS SERIES D EMERGENCY LIGHTING EQUIPMENT

LUCCI AIRFUSION QUEST II CEILING FAN

LED MOTION ACTIVATED FLOOD LIGHT

EBDSPIR-PRM, EBDSPIR-PRM-IP

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW

LiteAide OWNER'S MANUAL PREASSEMBLED AUTOMATIC SECURITY FLOODLIGHTS MOTION SENSOR SECURITY LIGHTING SYSTEMS

16/32 Channel 1U Rack Mount CCTV Power Supply

SECURITY LIGHT. motion-activated. Assembly & operating instructions Solar Motion-Activated Security Light - 80 LED Lights

Installation Instructions

3 IN 1 BATHROOM HEATER

WHYNTER 21 Bottle Dual Temperature Zone Freestanding Wine Cooler

Wireless Indoor/ Outdoor Thermometer

1 Safety instructions. 2 Device components. 3 Function. Leader in Led solutions. Compact presence detector. Operating instructions

2400W PIR LIGHT C O N T R O L L E R Cat No. SLW2400

Wireless Home Security Alarm System AM 500

ALL WEATHER W-SERIES QUARTZ TUBE ELECTRIC INFRARED RADIANT HEATER INSTALLATION USE & CARE MANUAL

PIR Motion Detector INSTALLER GUIDE E-700. SF-SA-140 -B.qxd 16/05/ :19 Page 1

Infrarot-Bewegungsmelder IP44

Please read this owner s Manual carefully before operating the unit. - Cooling - Heating - Dehumidifying - Fan

Owner s Manual & Safety Instructions

Rapide Inline Ceiling Extractor Fan, White Fascia Rapide Inline Ceiling Extractor Fan, Chrome Fascia

Installation & Maintenance Instructions

IMPORTANT SAFETY INSTRUCTIONS WARNING READ AND SAVE THESE OPERATING AND SAFETY INSTRUCTIONS BEFORE USING THIS HEATER.

PASSIVE INFRARED INTRUSION DETECTOR PASSIVE INFRAROOD DETECTOR DETECTEUR D INTRUSION PASSIF INFRAROUGE

USER MANUAL WARNING! CONTENTS MODEL 1 SPECIFICATIONS READ ALL INSTRUCTIONS BEFORE PROCEEDING. Non-Programmable Single Stage Heat/Cool Thermostat

Utility Distribution Systems

PIR Motion Detector E-808

Generator Transfer Switch Model # HTS15-AUTO

2.0 Installation 1. Remove the cover using a small flat blade screwdriver. Figure 2: Cover Removal

1. SAFETY RULES. 8. Avoid placing objects in the path of the blades.

DC REFRIGERATORS 12/24 VOLTS INSTALLATION AND OWNER S MANUAL

ASSEMBLY &OPERATING INSTRUCTIONS Solar Motion-Activated Security Light - 80 LED Lights Model #40225

TABLE 1. Rugged cast aluminum alloy casing,celcon waterways with nichrome parts White (unless stainless steel housing)

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CHCSCS

Name of Equipment Silver King Model SKMCD1P/C1. This equipment chapter is to be inserted in the appropriate section of the Equipment Manual.

Application and Instruction Manual Motion Activated Solar Powered LED Security Light with Camera MODEL: XP-2H38WC

Pre-Fab Easy Installation For Models: 006-CT-USK, 008-CT-USK Installation and Operating Instructions for Existing Homes with Standard Piping

TWIN EAGLES ALL WEATHER ELECTRIC RADIANT HEATER

INSTALLER S & OWNER S MANUAL

USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR

Installation and Operating Instruction Manual

For Models #6-5001, #6-7501, # & #10-12K1

PIR Motion Detector INSTALLER GUIDE E-806. SF-SA-360-CS-W.qxd 12/04/ :34 Page 1

Operation Manual. 150 Watt Halogen Light Source for Endoscopy Model # s ESS-150, ESS-150A ESS-220, ESS-220A

12 Volt 30 Amp Digital Solar Charge Controller

User Manual THR840DUK Digital Thermostat

TRANSFORMER HD-HAMPTON HAMPTONBAY.COM

Model Owner s Manual. Español - P. 19 Français - P. 39

RI-215A Operator s Manual. Part Number: RK Revision 0 Released: 10/3/05

INSTALLATION INSTRUCTIONS

INSTALLATION USE & CARE MANUAL ALL WEATHER SL-SERIES QUARTZ TUBE ELECTRIC INFRARED RADIANT HEATER

INSTALLATION AND OPERATION INSTRUCTIONS - (LOW FLOW MODELS) (Before installation, compare electrical needed for the model of heater selected)

IMPORTANT INSTRUCTIONS & OPERATING MANUAL. Houston 50 Inch Electric Wall Mounted Fireplace Black / White

ELECTRICAL GUIDELINES FOR SINGLE-FAMILY HOME OWNERS:

DTM04 TANK MONITOR DTM08 TANK MONITOR Dtm12 TANK MONITOR. Installation and Operation Manual

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

NO-FROST CUSTOMER SUPPORT INFORMATION INFORMATION ON THE NO-FROST TECHNOLOGY WHITE GOODS

Owners & Installation Manual for the Sheridan, Mountainair, Pine Valley and Old Forge Ceiling Fan Family

INSTALLATION INSTRUCTIONS GT8500E / GT8501E MASTER FLUORESCENT FIXTURE / SLAVE FLUORESCENT FIXTURE

Control Box Wiring For PRSstandard Tool

Roof Top Air Conditioner INSTALLATION AND OPERATING INSTRUCTIONS

FIXTURE INSTALLATION GUIDE Model T21T (Low Voltage Pendant Set 120V)

PROFESSIONAL HOME ALARM SYSTEM. Important! Please read these instructions carefully.

8-Ohm Ceiling Speakers For Music and Home Theater

Dimmer and Bulb Compatibility

With colder weather approaching and heating costs continuing to skyrocket, ASHRAE is offering some simple ways to save energy and keep you and your

Mini Tank. Electric Mini Tank Water Heaters WM-1.0 WM-2.5 WM-4.0 WM-6.0. Installation and Operating Instruction Manual

OLS-2100 Occupancy Light Switch

Ducoterra Radiant Heating Panel Installation Manual

WIRELESS SENSOR BATTERY REPLACEMENT INSTRUCTIONS For Safewatch Residential Control Panels

High Bay Occupancy Sensor Selection Guide

Passive Infrared Sensor Alarm

MAC FAUCETS. Owner s Manual. Models: FA444

12-Volt Negative Ground Installation Instructions

Operating Instructions

CONTROL PANEL INSTALLATION INSTRUCTIONS. Single Phase Simplex Page Phase Simplex Page 8-13

BATHROOM HEATER. User's Manual. Page 2...A515 Page 9...A716

THERMONET UNDERFLOOR HEATING STANDARD THERMOSTAT KIT STOCK CODE 5260

Wine Cooler with Thermo-Electric Cooling & Heating Technology

Mini-led spotlight with magnetic base

ELECTRIC CONVECTION BUILT-IN OVEN

90 Degree PIR Wireless Security Sensor. Installation Instructions 5420/90F

DUST COLLECTOR 70 GALLON, 2 HP

Transcription:

Features SMART SWITCH OCCUPANCY SENSOR Installation Manual Maximum Energy savings Sensitive 180º view passive infrared motion detector keeps lights on only when rooms are in use. No ON switch so lights are never left on by mistake. Compact design fits standard switch boxes with plenty of room for wiring. Tamperproof control panel cover reduces call backs for tampering. Maximum Versatility Meets California Title 24 standards. Switches all types of fluorescent and/or incandescent lighting. Suitable for all utility rebate programs Fits single or multi-gang locations without special adapters. Maximum Coverage 180º wide angle detection pattern Picks up people entering doorways quickly with standard next to doorway location. Covers 1000 square feet, eliminates needs for multiple sensors. Superb small movement sensitivity within 18 feet. Great for sedentary office use. No dead spots with 18 sensing fingers. Easy Installation Works with electronic ballasts. No minimum load requirement. Replaces single pole wall switches without additional wiring. Decorator style, rectangular switchplate included. Only 1/2 protrusion from switch plate. No adjustments required for most installations. 1

Specifications Coverage: 1000 square feet, up to 32 from the sensor Detection Zone: 180º in 18 zones 32 range Detection Pattern: 32 5 Side View 32 Note: Detection of sedentary small movement (desk work) within 18 Time Adjustment: 8 seconds to 15 minutes after motion stops (approximate) Detection Indicator: Red LED Energy Codes: Complies with California Title 24 Switching Capacity: 120v: 800w Incandescent & 277v: 1200w Incandescent & Power Consumption: Negligible Wiring: Replaces single pole wall switch, 3 wire system where neutral & hot are present. Temperature Range: -4ºF to +104ºF (-20ºC to +40ºC) Humidity Range: 93% relative humidity Approvals: UL Listed Photocontrol UL Standard 773A Weight: 3.3 oz. (no box) Parts List: LOS800 Matching Wall Plate 2 matching wall plate screws 2 sensor mounting screws Dimensions: A=4.06 (103mm) B=1.69 (43mm) C=2.25 (57mm) D=2.56 (65mm) E=1.25 (32mm) F=.5 (13mm) G=1.68 (43mm) A D 1Selecting A Location Locate the LOS800 where it has an unobstructed view of the room, particularly the areas normally occupied by people. Ideal mounting height is 3.5 to 4.5 feet above the floor. If people cannot see the sensor lens from their normal positions in the room, the sensor will not detect their presence. High cabinets, walls, doors and other obstructions may limit the sensor s view of the entire room. If obstructions can be moved the sensor will have a better view. If the areas obstructed are not areas normally occupied, the sensor will still be able to see normal occupancy. Cabinet obstructs sensor s view of active area Obstruction moved, sensor has full view If the room is L shaped or the sensor s view is badly obstructed from the door switch location, use the LOS2500 ceiling mounted sensor instead of the LOS800. Ceiling mounted LOS2500 sensor with 360º detection 50 Top View 50 Do not locate sensor over or looking at heating vents, baseboard heaters, hanging plants or air conditioners. Do not locate sensor where it will view direct sunlight. If the sensor s location gives it a view of the other rooms or hallways, lights will be turned on when movement is detected in these adjacent areas. If this is undesirable, the sensor s detection zone may be restricted by covering a portion of the lens with a white paper label or tape. has view of adjacent area Minimum Load: None E B F G C 2 3

2Installation 3Wiring Diagrams Caution: TURN OFF ALL POWER BY REMOVING THE POWER FUSES OR TURNING OFF THE CIRCUIT BREAKER FOR YOUR SAFETY AND TO PREVENT DAMAGE TO THE UNIT. Installation Step by Step 1. Remove the existing switch, if necessary. 2. Connect as shown in the wiring diagrams. See page 3. Caution: TURN OFF ALL POWER BY REMOVING THE POWER FUSES OR TURNING OFF THE CIRCUIT BREAKER FOR YOUR SAFETY AND TO PREVENT DAMAGE TO THE UNIT. Basic Wiring Diagram Single Level Lighting COMMON (WHITE) HOT (BLACK) Please read this entire Owner s Manual before installing. All wiring should comply with local electrical codes and requires a qualified electrician. 3. Twist on wire nuts. Secure with electrical tape. Mount LOS800 in wall box with two screws provided. 4. Place switch in OFF position before turning on power. The supply ground wire must be tightly secured to ground. 3-way Switch wiring Diagram Make sure the total lighting load connected to the LOS800 does not exceed the following: 120v: 800w Incandescent & 277v: 1200w Incandescent & Exceeding the wattage limits may damage the unit. To switch more wattage, an electrician can install a relay to handle the load. 5. Press the Auto/Off switch IN to Auto. After a short delay, the lights will turn ON. When the room is vacated, the lights will turn OFF after the time delay you set. 6. See Adjustments section for control options. Only make adjustments after a 3 minute warmup period. 7. Attach the wall plate. BLACK WHITE/COMMON BLACK/HOT BLACK BLACK Multiple Level Lighting Wiring Diagram COMMON (WHITE) Do not use LOS800 to control high intensity discharge lights, fans, heaters or motors. Small bathroom exhaust fans may be used with LOS800. The LOS800 may be used with both standard and electronic fluorescent ballasts. WALL MOUNTING BOX Black Red HOT (BLACK) White Black ADJUSTMENT ACCESS COVER (Removable only when switch plate is off) 4 5

4Adjustments 5Troubleshooting Field of View Adjustment Time Delay Adjustment Lights do Not Turn On Lights Go On for No Reason If the sensor is seeing out through a doorway into a hallway or seeing undesired areas, simply cover part of the sensor lens with opaque white tape or a paper label. Clear tape may be used, but it limits detection only partially. Test that the portion of the lens covered limits detection as desired and does not reduce detection in other areas. has view of adjacent area Removing the Adjustment Access Cover: This cover is tamperproof and can not be removed if the switch cover Plate is attached. The cover has two ears that hook under the cover plate and prevent tampering. To remove the cover insert a screwdriver into the latch and pull forward. The time delay adjustment can be set so the lights turn off from 8 seconds minimum to 15 minutes maximum after the room is vacated (approximate). Walk Test To test the detection pattern of the LOS800, make no motion for 30 seconds. Move sideways up to 12. The red LED flashes once every 4 seconds when turned on initially and twice every second to show detection. Hole for Coverplate screw 5 6 Mounting screw LED for walk testing detection indicator Motion lens Time delay (8 second minimum- 15 minute maximum) Turn the control gently clockwise with a small screwdriver for more time delay. Auto/Off switch auto (In) Off (Out) Mounting screw Hole for Coverplate screw. Over tightening screw will strip threads. 1. Check that: the lamps and fixtures work; wiring exactly matches the wiring diagram; wiring polarity is correct; power is on; sensor has warmed up for 3 minutes; off/auto switch is not OFF 2. Make sure sensor s view of the room is not blocked Lights do Not Turn Off 1. Check that the Time delay control is set to minimum. 2. Stay completely out of the protection pattern to avoid activation. 3. Make sure sensor is not seeing movement in an adjacent area through a doorway or other opening. 4. Make sure unit is not aimed at something that would move or cause a temperature change such as hot water pipes, air conditioners or heating vents. 5. Check that the wattage controlled does not exceed the maximum limits. Lights Go On and Off Quickly 1. Check that wattage controlled does not exceed maximum limits. 2. Certain energy saving fluorescent lamps strobe when turned on within a minute of being turned off. 1. Look for sources of electrical noise such as fans or air conditioners on the same circuit or nearby. If possible, unplug or move the noise sources. 2. Check if sensor is seeing into adjacent rooms or hallways. Mask sensor lens in that direction with opaque tape. 3. Check if sensor is seeing heaters or air conditioning vents. Mask sensor lens if necessary. 4. Make sure unit is at room temperature. If it was installed immediately after being in an extremely hot or cold environment, wait an hour for it to adjust. Insert small screwdriver into slot and pull forward 6 7

Limited Warranty An LOS800 Smart Switch requires no maintenance other than keeping the lens area clean and free of obstructions. do not attempt to open or repair the unit. There are dangerous voltages inside the case and no user serviceable parts. Your LOS800 will be replaced or repaired, at our option, if it proves to be defective in workmanship or materials within one year from the date of original purchase. For repair or replacement, return the product freight prepaid and insured to the address below. The LOS800 should be packed carefully. Please include your sales receipt and a description of the problem. If your unit is out of warranty or the damage is unrelated to its original manufacture, return your unit directly to RAB with a check for $20.00 (payable to RAB Lighting). We will repair or replace the unit. Under no circumstances shall we be liable for any incidental or consequential damages arising out of or in connection with the use or performance of this product or other indirect damages with respect to loss of property or revenue or cost of installation, removal or reinstallation. This warranty gives you specific legal rights and you may also have other rights which vary from state to state. 170 Ludlow Avenue, Northvale, NJ 07647 USA Over 30 warehouses nationwide. Tech Help Line Fax Back Website e-mail 888 RAB-1000 888 RAB-1236 www.rabweb.com sales@rabweb.com 8