EMERGENCY VAPOR SCRUBBER SYSTEMS



Similar documents
Sewage and Wastewater Odor Control Dr. Giancarlo Riva, Ozono Elettronica Internazionale, Muggio, Italy

Explosion-Proof Electric Unit Heaters

Guidelines for Preparing for a Temporary Steam Plant

More inside :: Tackle even the toughest water treatment piping challenges with

BOILER FEED AND CONDENSATE RECOVERY SYSTEMS Extend the life and efficiency of your boiler system

Medical Air Systems: Scroll

A GUIDE TO SELECTING YOUR INDUSTRIAL OVEN

MOBILE FIRE - RESCUE DEPARTMENT FIRE CODE ADMINISTRATION

SIOUX HYBRID WATER HEATER

Federal Wage System Job Grading Standards for Air Conditioning Equipment Operating, Table of Contents

Fire Pump Plan Review March 2010

Commercial Gas Water Heaters

COMPOSITE MESH PAD (CMP) DRY SCRUBBERS III TM ENFORCER III

INSTALLATION OPERATIONPERATION MAINTENANCE

/ Marley QuadraFlow Cooling Tower /

Electronic Flow Switches

COMPARISON OF PROCESS FLOWS: FLUID BED COMBUSTOR AND GLASSPACK

Power consumption (kw)

Design & Construction Standards, Revised January

4000 Series 4008TAG2A Diesel Engine ElectropaK rpm

D Youville College July 31, 2008 New Academic Building Cannon Design Project No

USER S, MAINTENANCE and SERVICE INFORMATION MANUAL

A practical guide to restrictive flow orifices

GEP550 (3-Phase) 50 HZ. 500 kva / 400 kw FEATURES. Exclusively from your Caterpillar dealer

Technical Support Services Accelerated Learning Through the Visual Presentation of Technical Information

P 602. This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

Recommended Product Specifications Fuel Day Tank System Tramont UTRS Fuel Day Tank

Emergency Showers and Eyewashes Mike Adkins Wednesday, October 31, 10:00-11:1511:15 a.m.

Chlorine Gas Detection System Operation & Maintenance

Element D Services Plumbing

Process Heater Burners, Flare Systems, Thermal Oxidizers and Catalyst Systems. Combustion Technology

Cooling Systems 2/18/2014. Cooling Water Systems. Jim Lukanich, CWT ChemCal, Inc. Grapevine, TX

PACKAGE TERTIARY FILTER SYSTEM SPECIFICATIONS MODELS TF-2-6-C THROUGH TF-2-35-C

OptiNet Applications. A Review of the Unique Requirements for a Facility Monitoring System. White Paper Series

SECTION HEATING, VENTILATION AND AIR CONDITIONING EQUIPMENT

Walnut Drying Design and Operation. Selecting Dryer Type. Tray Drying Before Don Osias Jim Thompson

Sulfur Tail Gas Thermal Oxidizer Systems By Peter Pickard

MC4-50 Feeding System

A placard provides the viewer with a variety of information through several different methods. First is the color of the placard.

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

DLW 8. POWER RATING 1500 rpm/50 Hz 1800 rpm/60 Hz Prime 7.5 kva, 6 kw 9.1 kva, 7.3 kw Standby 8.5 kva, 6.8 kw 10.1 kva, 8.1 kw

ABC CIRCUITS 10 Circuit Drive Circuit Town, IN SLUG CONTROL PLAN

OWNER S MANUAL BIG BEAR VORTEX FAN MODEL #BB-1 INTRODUCTION OPERATION SAFETY SERVICE WARRANTY CONTACT SPECIFICATIONS TROUBLESHOOTING

HYDRYER TYPE P Heat Regenerative Dryers ISO 9001 CERTIFIED

Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling

SECTION 5 COMMERCIAL REFRIGERATION UNIT 22 CONDENSERS

Commercial Gas Water Heaters

INTRODUCTION. Fact Sheet: Air Pollution Emission Control Devices for Stationary Sources

Fire Protection Pumps

Gas Unit Heaters Duct Furnaces Horizontal - 60 HZ Form No. LF (10/2011) LF24 Standard

Chapter 6 Odor Control

Commercial Gas Furnace Upflow

LyoBeta. R+D Freeze-Dryers

Stanadyne Fuel Manager Diesel Fuel Filter/Water Separator System. User s Guide

High Efficiency Copper Finned Tube Boilers 750,000-2,000,000 BTU/HR

TYPICAL FIRE SAFETY INSPECTION VIOLATIONS

Continuous Monitoring of Flue and Combustible or Hazardous Gases and Vapors

PAINT BOOTH LIGHTING

Recirculating Roof Fans Models ESRMD, ESRMDF and ERD

CETA Application Guide for the Exhaust System Requirements of Class II, Type B Biosafety Cabinets CAG March 24, 2010

Water Treatment and Reverse Osmosis Systems

GTS. New! Plus: PR0DUCT CATALOG. Vapor-logic 4 controller with: and LonTalk. New models GTS-500 and GTS-700. Gas-to-Steam Humidification System

Putting a chill on global warming

NEEP ShallowTray Low Profile Air Strippers

32:(5#5$7,1* 4833#USP283#+] 4;33#USP293#+] 3ULPH 10.4 kva, 8.3 kw 12.9 kva, 10.3 kw 6WDQGE\ 11.3 kva, 9 kw 14.4 kva, 11.5 kw

Phoenix Process Engineering, Inc. Project Experience Helping Clients Achieve MACT Compliance

Drum Dispensing Stations

Ammonia Detection System Codes and Design Specifications

UPBLAST & HOODED PROPELLER ROOF VENTILATORS

Duron UV System YoU adjust to changing conditions it S time YoUr UV SYStem DoeS too

PowerPlus. Integrated Power Distribution Cabinets. Most effective space-saving. integrated system on the market. Engineered to be shipped as a

C. Burner management system to follow requirements of Industrial Risk Insurers (IRI).

BC & BCH SERIES INDOOR / OUTDOOR INSTALLATION

Mechanical, Plumbing, and Fire Protection Conditions

Cooling Capacity CFM in. w.c. (125 Pa)

C18 ACERT Fire Pump Tier bkw/ rpm

STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM

HYDROSTATIC TEST PUMPS

The Single Absorption Scrubbing Sulfuric Acid Process

Scepter PVC Molded Junction Boxes

Waste Collection Systems

OASIS-PLUS 120V READ ALL INSTRUCTIONS BEFORE OPERATING READ ALL INSTRUCTIONS BEFORE OPERATING OZONE IS A POWERFUL OXIDIZER AND MUST BE USED WITH CARE

SUBMERSIBLE PUMPING SYSTEMS SUBMERSIBLE TURBINE PUMPS

QSV Series Vacuums an EnPro Industries company QUINCY QSV SERIES ROTARY SCREW VACUUM PUMPS 7.5 HP TO 200 HP

Thermal and Catalytic Oxidation Systems

Class II Type B2 Laminar Flow Biological Safety Cabinets at Ordering Criteria for the National Institutes of Health

AUTOMATIC CHANGEOVER MANIFOLD Series 915

New 27 hp 2 Cylinder Liquid-Cooled Engine

300 Series PA Pump and Cooler Assemblies

GAS EXTINGUISHING SYSTEMS INERT GAS EXTINGUISHING SYSTEMS. Argotec Liquid Argon Gas Extinguishing Technology (LAR)

DIESEL GENERATOR SET. 60 Hz FEATURES GENERATOR SET

Technical Specification. Generating Set with Waukesha engine burning natural gas

Magnum Mobile Generator MMG55 Specifications

PACKAGE WASTEWATER TREATMENT PLANT SPECIFICATIONS 3,000 GPD 100,000 GPD PLANTS

MEDICAL AIR STATIONS FOR MEDICAL GAS PIPING SYSTEM. Key features: NOVAIR quality and service:

Derakane epoxy vinyl ester resins: The Evolution of Corrosion Resistant FRP

SECTION MORTUARY REFRIGERATORS

ANNEX 17 DRAFT AMENDMENTS TO SOLAS REGULATIONS II-2/4 AND II-2/16. Part B Prevention of fire and explosion

Transcription:

EMERGENCY VAPOR SCRUBBER SYSTEMS

Toxic gases such as chlorine, sulfur dioxide and ammonia are commonly used for water and wastewater treatment, and in many industrial fabrication processes. The Uniform Fire Code Article 80 establishes strict standards for storing and handling toxic gases. Any facility that uses these gases must be prepared with a stand-by emergency scrubber system that will contain, absorb, and neutralize a release of the gas. This scrubber must reduce toxic emissions to less than 1 /2 the Immediate Danger to Life and Health value. In addition, as of June 30, 1999, the Clean Air Act requires that any facility that stores toxic gas must prepare a Risk Management Plan (RMP). An emergency vapor scrubber system is an essential component of an effective RMP. To this end, RJ Environmental Products offers a complete line of emergency vapor scrubbers. Our emergency chlorine scrubbers have been rigorously tested by a C.A.B.O.* certified laboratory. In 1992 and 1997, full-scale tests were conducted with actual one-ton releases of chlorine gas. On both occasions, our scrubbers passed the test with flying colors, neutralizing the toxic gas while maintaining emissions well below the 5 ppm UFC requirement. A unique 38,000 cfm chlorine scrubber was also tested at release rates up to 300 lbs./min, with no emissions exceeding 1 ppm. Our equipment has been proven beyond question. Our knowledge, experience, and technology are unequalled. * Council of American Building Officials

THE RJ-2000 TM EMERGENCY VAPOR SCRUBBER SYSTEM RJ-2000 SYSTEM SETTING THE STANDARD The RJ-2000 TM Emergency Vapor Scrubber System sets the standard for emergency vapor treatment in the water and wastewater industries. The RJ-2000 is a patented, multi-stage wet scrubber system that is uniquely designed to handle extreme gas release rates and to achieve exceptional removal efficiencies. All systems are manufactured from the highest quality components and materials, including premium vinylester FRP construction. GUARANTEED PERFORMANCE A leak from a one-ton chlorine storage tank can release chlorine gas at a rate of 100 lbs/min or more, with inlet concentrations exceeding 500,000 ppm. To reduce the concentration to less than 1 ppm, the RJ-2000 must remove 99.9995% of the chlorine. Our ability to provide this level of performance is based on first-hand experience with full-scale, one-ton gas release tests performed by an independent C.A.B.O. certified laboratory. LOW COST INSTALLATION & MAINTENANCE Each RJ-2000 system is factory assembled and mechanically tested prior to shipment. The patented compact design minimizes the height and footprint and lowers installation and maintenance costs substantially. THE INDUSTRY LEADER Since its introduction in 1992, the RJ-2000 Emergency Vapor Scrubber System has become the industry leader, with more than 300 installations worldwide. California City WWTP, CA

THE RJ-2000 TM PROCESS SYSTEM DESIGN The RJ-2000 system uses a patented, multi-stage packed bed design. A pre-treatment stage handles extremely high gas concentrations, while subsequent high-efficiency stages remove the remainder of the toxic vapors. The systems are designed for releases of chlorine, sulfur dioxide, or ammonia. The schematic diagram below illustrates the scrubbing process. When a leak occurs, the pump and fan start automatically. The fan provides sufficient vacuum to contain the toxic vapors within the gas storage room. The toxic vapors are then pulled into the scrubber system, where they are absorbed by a concentrated caustic (sodium hydroxide) solution. The RJ-2000 system is designed to start automatically and to continue running until manually shut down. For ammonia applications, the system operates on a once through water basis. No recirculation pump is required and no caustic is used. INLET W PACKING FLOW FLOW TO ATMOSPHERE Major system components include: 1. FRP Three-Stage Scrubber FLOW 2. FRP Air Exhaust Fan PACKING FINE SPRAY 3. Caustic Recirculation Pump 4. Electrical Control Panel H 5. Caustic Storage Tank [Note 1] System options include: Automatic backup pump CAUSTIC STORAGE Insulation and sump heater Integral secondary containment L Stack gas sensor Weather cover and stack rain hat RJ-2000 DESIGN INFORMATION Note 1: Tank is integral to system on RJ-150 and RJ-2000 models Design Air Flow Rate [1] Caustic Volume [2] Dimensions Shipping Operating Fan Motor Pump Motor Capacity (cfm) (gal.) L x W x H Weight Weight (HP) (HP) (tons) (ft.) (lbs) (lbs) 1 3,000 2,100 13.0 x 7.0 x 8.5 7,500 29,000 5 20 2 3,000 3,900 13.0 x 8.0 x 11.0 10,000 50,000 5 20 3 3,000 5,900 13.0 x 9.0 x 12.5 14,000 72,000 5 20 [1] Air flow is based on gas storage room volume and may be adjusted as necessary. [2] Caustic volume is based on 20% concentration by weight and a minimum of 50% excess.

THE RJ-2000 TM BULK SERIES BULK SYSTEMS Facilities that store 4 or more tons of toxic gas may require the RJ-2000 Bulk System. The Bulk System consists of a standard RJ-2000 scrubber mounted to a flange on top of a bulk caustic storage tank. The caustic storage tank is sized to supply sufficient sodium hydroxide to neutralize the largest possible gas leak. The recirculation pump and fan are also mounted on top of the bulk tank, while the control panel is usually mounted at ground level. Depending on the volume of the gas storage room, the air flow rate is typically Roger Road WWTP, Tucson, AZ 3,000 to 5,000 cfm. RJ-2000 BULK SYSTEMS SINGLE TANK DESIGN INFORMATION Design Air Flow Rate [1] Caustic Scrubber Dimensions Tank Tank Overall Fan Motor Pump Motor Capacity (cfm) Storage Tank [2] L x W x H Diameter [3] Height [3] Height [4] (HP) (HP) (tons) (gal.) (ft.) (ft.) (ft.) (ft.) 4 3,000 6,500 9.0 x 7.0 x 5.5 14 7.0 12.5 5 20 6 3,000 9,800 9.0 x 7.0 x 5.5 14 10.0 15.5 5 20 10 3,000 13,800 9.0 x 7.0 x 5.5 16 10.5 16.0 5 20 20 3,000 27,700 9.0 x 7.0 x 5.5 18 16.0 21.5 5 20 25 3,000 34,600 9.0 x 7.0 x 5.5 20 16.0 21.5 5 20 30 3,000 41,500 9.0 x 7.0 x 5.5 24 13.5 19.0 5 20 55 3,000 76,000 9.0 x 7.0 x 5.5 28 18.0 23.5 5 20 90 3,000 124,000 9.0 x 7.0 x 5.5 36 18.0 23.5 5 20 [1] Air flow is based on gas storage room volume and may be adjusted as necessary. [2] Caustic volume is based on 20% concentration by weight and a minimum of 25% excess. [3] Tank diameter and height can be altered to change footprint. Horizontal configuration and/or multiple storage tanks can be designed. [4] Overall height includes scrubber (stack height is not included).

THE RJ-150 SERIES RJ-150 SERIES The RJ-150 is a smaller version of the RJ-2000 system. It is designed to contain and neutralize releases from 150 pound gas cylinders. Systems are typically designed for 2, 4 or 6 on-line gas cylinders, as listed below. The systems can be used to treat releases of chlorine, sulfur dioxide, or ammonia vapors. RJ-150 Chlorine Scrubber RJ-150 DESIGN INFORMATION System No. of Air Flow Caustic Dimensions Shipping Operating Fan Motor Pump Motor Cylinders Rate [1] Volume [2] L x W x H Weight Weight (HP) (HP) Online (cfm) (gal) (ft.) (lbs.) (lbs.) RJ-150-2 2 250 250 7.0 x 3.0 x 4.66 1,000 3,500 1 3 RJ-150-4 4 250 500 7.0 x 3.0 x 6.25 1,250 6,250 1 3 RJ-150-6 6 250 660 7.0 x 3.0 x 7.5 1,500 8,100 1 3 [1] Air flow is based on gas storage room volume and may be adjusted as necessary. [2] Caustic volume is based on 20% concentration by weight and a minimum of 33% excess. RJ-150-PP SERIES The RJ-150-PP Pre-Packaged series combines gas storage, water treatment, and emergency vapor scrubbing into one skid-mounted or trailer-mounted system. Systems can be designed for chlorination, dechlorination, or ammoniation purposes and are ideal for remote locations. The units are factory-assembled and include a standard RJ-150 scrubber and a 48 sq. ft. FRP shelter which houses the system controls, water treatment equipment, gas cylinders, and gas detection equipment. Eastern Municipal Water District, CA

THE RJ-150-PP SERIES RJ 150-PP DESIGN INFORMATION System No. of Air Flow Caustic Dimensions Shipping Operating Fan Motor Pump Motor Cylinders Rate [1] Volume [2] L x W x H Weight Weight (HP) (HP) Online (cfm) (gal) (ft.) (lbs.) (lbs.) RJ-150-2 2 250 250 11.0 x 8.5 x 7.5 4,700 7,200 1 3 RJ-150-4 4 250 500 13.0 x 8.5 x 7.5 5,000 10,000 1 3 RJ-150-6 6 250 660 13.0 x 8.5 x 7.5 5,150 11,850 1 3 [1] Air flow is based on gas storage room volume and may be adjusted as necessary. [2] Caustic volume is based on 20% concentration by weight and a minimum of 33% excess. EMERGENCY VAPOR SCRUBBER ALARM BEACON Compact unitary construction Factory assembled and tested FRP premium grade vinylester resin Integral chemical storage UV protection EXHAUST FAN FRP centrifugal Induced draft RECIRCULATION PUMP CPVC construction No seals or bearings No liquid/metal contact SECONDARY CHEMICAL CONTAINMENT EQUIPMENT SHELTER Construction: FRP EQUIPMENT SKID Construction: Carbon Steel Coating: Epoxy Paint VENTILATION FAN CHLORINATION EQUIPMENT DUAL CYLINDER SCALE BREAKER PANEL LOCAL CONTROL PANEL NEMA 4X panel Motor starters Push-to-test pilot lamps Equipment H-O-A switches Ready/running status out- LEAK DETECTOR STORAGE RACK FOR CYLINDERS Safe storage for back-up cylinders LIGHTING FIXTURES ROOM HEATER GRAVITY INTAKE (if

OTHER PRODUCTS ODOR CONTROL SYSTEMS LO/PRO Odor Control System RJ Environmental Products offers a full range of wet scrubber and carbon adsorption odor control systems, including: LO/PRO Packaged Odor Control System a patented, multi-stage scrubber which can do the work of conventional packed towers in less than half the space and at a fraction of the cost. Packed Tower Systems a traditional design that can handle large volumes of air. An extended sump deck enables the use of seal-less pumps for low maintenance and safe, easy access to instrumentation. Carbon Adsorption Systems useful for small air flows or remote locations, these systems can also remove organic compounds that are difficult to control with wet scrubbers. With hundreds of odor control systems operating worldwide, USFilter is the definitive industry leader. If you have an odor control problem, USFilter has the solution. RJ Environmental Products sets the standard for reliable, economical, and effective emergency vapor scrubber systems. RJ Environmental Products 6197 Cornerstone Court East, Suite 108 San Diego, CA 92121 Tel: (619) 455-7688 Fax: (619) 455-7689 EVSS-0399 http://www.usfilter.com