HMI display Installation Guide

Similar documents
Electronic Control Devices The European Product Catalogue 2007

Duct Humidity Transmitter

LIEBERT VNSA Installation Sheet

Electronic Control Devices The European Product Catalogue 2007

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

Digital input modules

PCS300 Universal IP Reporting Module V1.0

T7560A,B,C Digital Wall Module

PCS0100en Persy Control Services B.V. Netherlands

MAKING MODERN LIVING POSSIBLE. AK-SC255 On-Site Installation Guide DANFOSS ELECTRONIC CONTROLS & SENSORS

Installing the Tracer ZN517 Unitary Controller Ordering number: ,

Features. Introduction. Applications. VPD-130/VPD-130N with DIN-Rail Mounting. VPD-130/VPD-130N Panel Mounting. Excellent C/P ratio (cost/performance)

CompactRIO crio-9052

3500/93 System Display

How To Wire Wireline Cable To A Cell Phone (New Zealand)

INSTALLATION INSTRUCTIONS

Touch HMI Devices. The Best Choice for Building/Factory/Machine/Home Automation. Introduction. Features. Touch HMI Devices.

AMFA-27 AMFA-29. Operator s Manual & Installation Instructions. Rev. 2.5

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

Drayton Digistat +2RF/+3RF

I nstallation. M100Q Series Proportional Actuator with R81Q Controller Board for Thermistor Sensor Applications. Tools Needed.

OZW30. Central Unit SYNERGYR

DUAL SENSING DIGITAL THERMOSTAT PRODUCT INSTRUCTIONS. Construction Automotive Industry

ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL

T7079A,B Solid State Remote Temperature Controllers

Radiant Temperature Sensor TY7321

Advanced Power over Ethernet Controllers. Datasheet. Models: TS-5-POE, TS-8-PRO, TS-16-CARRIER. Gigabit PoE Ports. Intuitive Configuration Interface

HP UPS R1500 Generation 3

SHEET. BASautomation. BAS Router BACnet Multi-Network Router. BAS Router

Lighting Controls ! WARNING RISK OF ELECTRIC SHOCK. Installation Instructions DESCRIPTION

Parallel Redundant Uninterruptible Power Supply

Canopy Surge. User Manual

Automatic Transfer Switch FT-10 Network Control Communications Module (CCM-T) Kit

2013 Wireless Video Intercom INSTALLATION GUIDE

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

Overview. Alarm console supports simultaneous viewing of both live and recorded video when alarm events are selected

NI NI C Series Overview DATASHEET. 8-Channel Sinking Digital Input Module

IntesisBox KNX Mitsubishi Heavy Industries AC

BACnet. bcx1 Controller/ Router Series

EVC40 EMERGENCY VOICE COMMUNICATION SYSTEM

TrueAlarm Fire Alarm Systems

MCR1900 Media Converter 19-Slot Chassis

Applied Electronics. Commercial Dimming System UPDATE NOTICE

INSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930

Infrastructure Management & Monitoring For Business-Critical Continuity. Liebert AC4. User Manual

AXIS T81B22 DC 30W Midspan

5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual

DS DRTE. AIR ROOM TEMPERATURE SENSOR with fan speed control switches

Moxa EtherDevice Switch

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)

Arecont Vision H.264 Color or Day/Night SurroundVideo Series Installation Manual

ADSL Modem Installation Guide. Model # 36R515 Part # Rev. D Revision Date 12/2000. ADSL Modem Installation Guide

Provides one channel for Ethernet over existing

SWITCH! DESCRIPTION. ENVIRONMENTAL SPECIFICATIONS Operating Temperature: 0 C to +40 C SPECIFICATION SHEET:

AI120 AIswitch Series 120 Chassis

Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION

PowerLogic Sub Meter Display (SMD and SMDOPN)

VLT Series 3500 Adjustable Frequency Drive Instruction Manual

FCC COMPLIANCE STATEMENT FOR AMERICAN USERS

40.3. Control Relays and Timers

MAC-821SC-E. Centralized On-Off Remote Controller. English ÏÏËÓÈÎ. Русский [FOR INSTALLER] INSTALLATION MANUAL

UniStream CPU-for-Panel

Alarm over IP. IRIS Touch Home Installation Manual. Version 1.0 ENGLISH. Now certified and compliant with EN50131, EN50136 Security Grade 4 ATS6

BACnet router for BACnet/IP BACnet/LonTalk BACnet MS/TP

TX OPEN RS232/485 module

Repeaters and Mimics Data Sheet

Heating Controller. Building Technologies HVAC Products

3DLevelScanner II TECHNICAL DATA SHEET

12 Volt 30 Amp Digital Solar Charge Controller

430 Power/Electronics Replacement

Operating Manual for the Electronic Built-in Interval Timer. Micro II (Countdown Timer)

RVL470. Heating Controller. Building Technologies HVAC Products. Series B

Version Date Author Description Jpo First version Jpo FET output descriptions made clearer

NEI-30 VEI-30 Dinion Infrared Imager NEI VEI Series. Quick Install Guide

Product Specification instalert Rapid Messenger Variable Message Sign

SECTION LOW VOLTAGE LIGHTING CONTROLS

Hollow or Cinder Block Wall Mount Job Aid

VOICE RECORDING SYSTEM ISDN PRI / BRI

AT&T. PARTNER Plus Door Phone. Installation and Operation Manual

=============================== WARNING

Machine-to-Machine Management System. Datasheet. Models: mport, mport-s, mpower, mpower Mini, mpower Pro, mfi-cs, mfi-ds, mfi-ths, mfi-msc, mfi-msw

SEZ220. Signal Converter. Synco 200. With preprogrammed standard applications Freely programmable Menu-driven operation. Use

IntesisBox Modbus Server Fidelio IP

AutoDome Easy II. VEZ Series. Mounting Manual

PT-6000 Power Tower INSTALLATION MANUAL SPECIFICATIONS

KNX Panasonic Air Conditioners

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

FX07 Field Controller

Programmable Terminal. NPSeries. Easy Setup with the Low-cost, Compact NP Series

FIRERAY 2000 Installation Guide

Model: DC-A2IO Advanced HVAC Controller

Model 201 Wiegand Touchpad Reader Installation Guide

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

HP-1000E v2. User s Manual. Powerline Ethernet Adapter. HP1000E v2 User s Manual

Square D Clipsal DIN-Rail Four-Channel Auxiliary Input Unit

PSU-U-24V/AC-6A/10/FTA-TR-MC PSAC 0624

LevelOne IFE Port PoE + 1-Port TP Industrial Fast Ethernet Switch User Manual

MINI MCR-SL-R-UI(-SP)

Transcription:

HMI display Installation Guide Product Description Specifications Important Information o Package Contents o Related Documents o Accessories Cautions and Warnings Mounting and Dimensions o BAC-DIS-ENC Direct Surface Mount (drywall, sheet metal) Direct Surface Mount (existing single or multi-gang box) Through Hole Panel Mount o BAC-DIS-ENC Surface Mount (with conduit) Drywall Flush Mount (new construction) Drywall Flush Mount (retrofit) Board Layout General Wiring Power Network Communication Appendix A - Through Hole Panel Mount Appendix B - BAC-DIS-ENC Dimensions

Product Description The HMI display is a seven-inch wide-screen format LCD touch display unit used for interfacing with a BACnet building automation system. The HMI display uses BACnet over Ethernet or BACnet/IP to communicate with the controllers on a local area network using real-time graphics. The HMI display can be wall or panel mounted in mechanical rooms which allows for monitoring and setting schedules for air handlers, boilers, chillers and other mechanical equipment. It is also designed to be mounted in public spaces. The HMI display can be used as a small building interface making it easy for occupants to change occupancy schedules, adjust temperature setpoints and view floor layouts.

Specifications Power 24VAC 50/60 Hz or 10VDC Class 2 Dedicated transformer Full-wave rectified Power Consumption 15.0 VA Max Ambient Ratings 32 to 131 F (0 to 55 C) 10 to 90% RH non condensing Communication Ports Ethernet 2x 10/100BaseT @ 10/100Mbps BACnet IP BACnet over Ethernet USB USB 2.0 Full Speed, (USB Flash Drives) Inputs Temperature Internal Thermistor (On- Board) 10,000 ohm @ 77 ºF (25 ºC) Accuracy of +/- 1.44 ºF from 32-131 ºF (+/- 0.8 ºC from 0-55 ºC) Stability of 0.24 ºF over 5 years (0.13 ºC) Jumper Selection for Internal or External Thermistor External Thermistor (Remotely Located) Use a standard 10K Thermistor (10,000 ohm @ 77 ºF / 25 ºC)

Dimensions 5.6 x 8.2 x 1.4 in. (142 x 208 x 35 mm) With Occupancy Sensor - 5.6 x 8.2 x 1.6 in. (142 x 208 x 40 mm) 1.014 lbs (460g) without BAC-DIS-ENC Technology 32-bit RISC ARM9 Processor @ 240 MHz 245MB Flash Memory (~195MB available for custom graphics and database) 128MB SDRAM Real Time Clock with 72hour Supercap backup Listings UL Listed (for US and Canada) Compliance UL 916 Energy Management Equipment CAN/CSA-C22.2 No. 205-M1983: Signal Equipment CEI IEC 61000-6-3: 2nd Ed. 2006 For Emissions CEI IEC 61000-6-1: 2nd Ed. 2005 For Immunity FCC CFR47 Part 15/B Class B ICES-003 Issue 4 Class B

Important Information HMI Configurator software BAC-DIS-XXX and controller firmware must all be of the same version number (i.e. 3.33) to be compatible. When upgrading any of these products from older versions (i.e. 3.22 or 3.30), you must upgrade all the remaining products. Package Contents Product: HMI display Related Documents HMI display Operator Guide Accessories BAC-DIS-ENC (includes retrofit clamps) - for surface mounting with conduit or flush wallboard mount (new and retrofit) Cautions and Warnings This controller is an Electro-statically sensitive device. Proper ESD protection (ground strap) should be used when installing this product so that damage to the product does not occur. Equipment damage or loss of data may occur if these procedures are not followed as specified. Installations requiring CE conformance: All wiring for CE rated products must use an extra low voltage (SELV) or protective extra low voltage (PELV) transformer. Use safety-isolating transformers, (Class II transformer) per EN61558. The transformer must be rated for 100% duty cycle.

Mounting and Dimensions The HMI display has the following mounting options: Direct surface mount Single or multi-gang box mount Through hole panel mount Using the optional BAC-DIS-ENC electrical box allows for additional mounting options: Conduit surface mount New drywall flush mount Retrofit drywall flush mount Mounting options without the BAC-DIS-ENC Figure 1: Dimensions (without BAC-DIS-ENC)

Direct Surface Mount (drywall, sheet metal) The HMI display is directly mounted to the wall surface, typically sheet metal for a panel door or drywall. This allows for the quickest and easiest installation and does not require the BAC-DIS-ENC. The HMI display will extend approximately 1.4in. (35mm) above the mounting surface. 1. Level the HMI display on the mounting surface. 2. On the surface, mark at least 4 screw holes and the pass through hole for the power and Ethernet cable. Note: Only use the holes show in Figures 2 and 3, not the holes shown in Figure 4 3. Cut a hole into the surface for the power and Ethernet cable to pass through, and drill screw holes if necessary. 4. Mount the HMI display using screws and wall anchors appropriate for the mounting surface. Direct Surface Mount (existing single or multi-gang box) Allows use with pre-installed single or multi-gang electrical boxes. The screw holes in the HMI display back plate line up with North American standard, and European standard electrical boxes. Figure 2: North American Standard Box Holes Figure 3: European Standard Box Holes Single- or Multi-Gang box Mounting Procedure

1. Use the holes on back plate to attach the HMI display to a single or multi-gang box. Use the appropriate holes for either North American or European standard electrical boxes (Figure 2 and Figure 3) Note: For a single or a double-gang box, use at least two wall anchors on the right side of the HMI display. 2. For multi-gang boxes, the Cat5 and power cable pass through hole on the HMI display aligns with the multi gang box furthest to the left. Through Hole Panel Mount This method is for a panel door mount when a flush appearance is desired. Once mounted the HMI display extends approximately 0.9 in. (22mm) above the mounting surface. 1. Cut a hole is cut into the surface. See Appendix A for sheet metal cutout specifications. 2. Mount the HMI display by using the 4 outside slotted mounting holes (see Figure 4) on the back of the HMI display. Use screws appropriate for the mounting surface. Figure 4: Outside Mounting Holes

Mounting Options with the BAC-DIS-ENC The BAC-DIS-ENC is not included with the HMI display. It is an optional metal electrical box which includes retrofit connectors to allow flush mounting the HMI display in existing drywall. Figure 5: HMI display with BAC-DIS-ENC Surface Mount (with conduit) Mounting on to a surface such as concrete or brick where conduit is used requires the optional BAC-DIS-ENC. ½ and ¾ inch knock-outs for conduit fittings are located on the 4 sides as well as the bottom of the box. See Appendix B for dimensions of just the BAC-DIS-ENC. The HMI display will sit approximately 3.0in. (76mm) above the mounting surface when installed in this manner. The retrofit connectors included with the BAC-DIS-ENC are not required. The HMI display is attached to the BAC-DIS-ENC using the 4 short screws included with the BAC-DIS-ENC.

Drywall Flush Mount (new construction) With new construction, installation is similar to that of a regular electrical box and does not use the BAC-DIS-ENC retrofit clamps. The BAC-DIS-ENC is attached to a stud prior to drywall installation and positioned such that when the drywall is mounted, it will be flush with the top of the BAC-DIS-ENC. When installed the HMI display sits approximately 0.9in. (22mm) above the drywall. When the wall surface is finished, the HMI display is attached to the BAC-DIS-ENC using 4 short screws (included with the BAC-DIS-ENC). Drywall Flush Mount (retrofit) The BAC-DIS-ENC is clamped to the drywall by tightening the 4 retrofit screws on the sides of the BAC-DIS-ENC. The HMI display will sit approximately 0.9in. (22mm) above the drywall. Attaching the Retrofit Connectors to the BAC-DIS-ENC 1. Remove the 4 rectangle knockouts on the BAC-DIS-ENC, labeled A on the below diagram. Figure 6: BAC-DIS-ENC with 4 Box Flanges Attached

2. Insert Tab C of the Box Flange into Slot C of the BAC-DIS-ENC. Rotate clamp into side of the box so Tab B of the Box Flange is inserted into Slot B of the BAC-DIS-ENC. 3. From the inside of the BAC-DIS-ENC, bend Tab B to the side with a pair of pliers to secure the Box Flange to the BAC-DIS-ENC. Repeat the above steps to attach the three remaining Box Flanges to the BAC- DIS-ENC as shown in Figure 7. Figure 7: BAC-DIS-ENC with 4 Box Flanges Attached 4. Inside the BAC-DIS-ENC, pass included 1-1/4in. Slotted machine screws through the hole of a Box Flange and into the threads of the Retrofit Clamp. Turn the screw just enough to start the threads into the Retrofit Clamp, so that it can pivot in and out of the rectangular knockout. Figure 8: Retrofit Clamps Pivoted Inward

5. Repeat for the 3 other clamp locations. Leave the 4 Screw/Retrofit Clamps rotated inside the box. This will allow inserting the BAC-DIS- ENC through the drywall without losing clamps or screws. Mounting the Box 6. Place the BAC-DIS-ENC into the wall, then pivot the 4 bottom clamps out of the box. Tighten each of the 4 screws until the box is clamped to the drywall. Do not over tighten. Figure 9: Retrofit Clamps Tightened 7. The HMI display is attached to the BAC-DIS-ENC using the 4 3/16in. Phillips machine screws included with the BAC-DIS-ENC

Board Layout The following Figure 10 shows the HMI display circuit board. This is a view from above, when the unit is opened and mounted on a wall. When closed, the reset button will be on the bottom of the unit. Figure 10: HMI display PCB Layout (not to scale)

General Wiring All wiring must conform to NEC and local codes and regulations. Use earth ground isolating step-down Class 2 transformers. Do not use autotransformers. Determine supply transformer rating by summing total VA of product and output loads. Risk of Electric Shock or Fire More than one disconnect switch may be required to deenergize the equipment before servicing. Do not interconnect the outputs of different Class 2 circuits. All terminals are acceptable for Class 2 Circuit connections only Use copper conductors only Apply minimum 4-5.5 lb-in torque for tightening field wires into the terminal blocks. Use 22-12 AWG wires. Power The HMI display is designed to use a 24VAC Class 2 power supply. The HMI display is a full-wave rectified device, therefore the HMI display requires its own dedicated transformer. The transformer must be properly sized for the total VA requirements. Network Communication The HMI display uses BACnet over Ethernet for communications. BACnet IP is support is added with BAC-DIS-ADV. The two Ethernet ports function as a 10/100 Mbps Ethernet switch, allowing daisy-chaining a second Ethernet HMI display, Ethernet controller or other Ethernet device. The two Ethernet ports operate at independent speeds.

Appendix A - Through Hole Panel Mount

Appendix B - BAC-DIS-ENC Dimensions