K17.12 Door closers K17. Doors 01.09.2013



Similar documents
K17.11 DOOR BOLTS K17 DOORS

How To Fit A T.V Door Closer

SOHOline and SOHO Slimline The SOHOline and SOHO Slimline offer a modular, sturdy and compact design

Lift-off hinge. Rising hinge. Standard hinge. Heavy duty hinge. Parliament hinge. Spring hinge. Double action spring hinge. Concealed mortise hinge...

TS83. Easy action door closer

BLADE S-MAX Cabinet for Blade Server

Hürriyet Mah. Dr. Cemil Bengü Cad. No.27/A Çağlayan / Istanbul

CDW Systems Ltd Contemporary Doors & Windows

Universal systems for frameless doors

Relevant British, European and International standards

TS93 EMR T/PT/TDE. Surface applied door closer

Sliding and Folding Door Fittings Sliding Door Accessories

Nightscape High performance floodlights and spotlights for discharge lamps

Linkeo 19" freestanding cabinets

ABLOY DC 240 DOOR CLOSER Heavy duty door closer

NEWSTAR BROCHURE. December 2007

IT infrastructure Efficiency-boosting solutions. nextlevel. for data centre

Heavy Glass Frameless Shower Door With Return Panel

DIGITUS Network & Server Cabinets. UNIQUE Series

F-Series Camera Mounting Accessories

KITCHENS. Tip PAGE 1 FITTING YOUR KITCHEN GUIDE. How to mark out a kitchen. Tools required for installing a kitchen STEP ONE STEP TWO STEP THREE

bts 80 f/emb/flb/bsr Floor spring system

Plaisance 24. Sliding Systems. Sapa Building System

WHI 90-Minute Rated Veneered Door Frame Installation Instructions

Technical data sheet PVC Bi-fold doors

INSTALLATION INSTRUCTIONS for Bifold Doors (JII103)

HINGES FOR OUTWARD OPENING APPLICATIONS. Friction Hinges. Parts Brochure

19 DYNAmax Free Standing Server C A B I N E T s

Data Centre Solutions

Fire Resistant Systems

Installation Detailed installation instructions are provided which should be strictly followed.

Fluxa Area floodlights for high pressure discharge lamps and LEDs

SERVER ROOM CABINET INSTALLATION CONCEPTS

EXTeRUS. EXTeRUS - With patented design, able to join technology. and quality of materials with a charming shape. Unique

Hinge Replacement & Hinge and Hardware Adjustment Guide for Andersen Frenchwood Hinged Patio Doors Manufactured Before November 2005

19 DYNAmax Free Standing Server C A B I N E T s

Confort 26. Sliding Systems. Sapa Building System

ABLOY DOOR AUTOMATICS Easy access for all types of swing doors

KIRÁLY TRADING KFT H-1151 Budapest Mogyoród útja tel: Clamps Clamping devices

DCF Optimized Rack System

Edition Perfect combination ratiopacpro Electronic P Edition kaging www clear order..biz information in the catalogue

HORIZONTAL INSTALLATION

Knürr DCM. Knürr DCM. 19 Server Rack System 19 Heavy Duty Rack 1.2 to

Concealed Door Closers

VITOSOL r 200-T SP2A. VITOSOL 200-T Type SP2A

ARCHITECTURAL. FritsJurgens Pivot Door System Product Range Brochure

1 Door Tall Unit ASSEMBLY GUIDE. Page 1 of 9. WARNING: Contains small parts, keep out of reach of children.

Wren Kitchens Installation Tips Carefully check your kitchen delivery Measuring out and marking up Fitting the base cabinets...

Guide to Safety Edge Systems

19" Data Racks. Adjustable feet To compensate for uneven floors and assure great stability all feet can be up to 20 mm adjusted.

19 NETbox SOHO Network Wall Mounting Cabinets FAMILY

SECTION 6. Glass Storefront Doors:

STORAGE DESIGN LIMITED

Series 18 Pass Thru Air Lock Cleanroom Entry System

Installation Instructions K900 series Door Closer

Industrial infrared heater IR For premises with large volumes and high ceilings

Narrow stile lock 1314

STB Series Enclosures

Easy-action Door Closer DORMA TS 83

SSG PRODUCTS FOR SHIPS AND OFFSHORE

Superlight Compact Nano

Can you design a frameless shower enclosure that doesn't leak?

50 TO 60 INSTALLATION INSTRUCTIONS v1.0

Removable Aluminium posts

DIY CABINET REFACING INSTALLATION GUIDE

PITCHED ROOF STRUCTURES

PC SOLUTIONS CABINETS. - Enclosures with PC front panels with innovative design - PC enclosures with sliding shelf - Workplaces for industrial PCs

Windows, French doors, folding windows, terrace doors SFB 1074 with low U-values

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

BAKA Protect Series 2000 / Protect. The adjustable hinge system for timber entrance doors

Important Information

Installation guide for the SafeLine type anchorage device. Tested in compliance with EN 795: No.: SE-...

Electric Rotary Actuator - On/Off or programmable control actuator

Rack Installation Instructions

K. D. FRAME ASSEMBLY FOR CLOSED STEEL STUD WALLS...Ins 10. FRAME INSTALLATION DETAILS FOR CLOSED STEEL STUD WALLS...Ins 11

Switchboard system. NorLine 800

Mechanical arms, belts and sheets

Guide to enclosures for potentially explosive atmospheres

Installing Shutters using Fasteners

English AUTOMATION SYSTEMS FOR SLIDING GATES. Operating and installation instructions SLIDE SERIES

Beadboard Wall Bookcase

Colonnade Security Pipe

mechanics PP-Profiles Panel Profiles PT-Profiles T-Groove Plates RE-Profiles Rectangular Profiles PU-Profiles Universal Profiles

ARCHITECTURAL. CEAM INVISIBLE HINGES new adjustable 3D concealed hinge products for swing doors 100% made in Italy

Twin EL Wall luminaires for halogen lamps or ceramic metal halide lamps

PHA 2000 PHB 3000 EXIT PAD

Rooflight INSTALLATION INSTRUCTIONS

2&3 SECTION LOFT LADDER

Rack installation instructions

Morgue refrigeration unit

Grilles & Diffusers Series LFP Incorporating

9300BC SERIES Light Commercial Door Closer

Isola Steel Gutters Strength and design for extreme climate!

PB accessories. PB accessories. Labelling option. Order Information B Printed board handle A BZA42727 BZA42724.

Cooktop Low-Profile Ventilation Hoods

Superlight Compact LED LED floodlights

PROLINE Go l d Se r i e s. Desk Consoles and Accessories

H45 LED - Direct and indirect pendant

Sliding Barn Door Hardware Installation Instructions BALDUR and ODEN

Medical Lighting. XL4 Patient Light

Transcription:

K17 Doors K17.12 01.09.2013 Waregemstraat 5-9870 Zulte - Belgium - T. +32 9 388 88 81 - F. +32 9 388 88 21 - commercial@sobinco.com - www.sobinco.com

Contents 1. OPTIC door closer TS40(V) with scissor arm...k17.12.03 1.1. Door closer with standard arm TS40 K17.12.03 1.2. Door closer with hold open arm TS40V K17.12.04 1.3. Optic door closer TS40(V) in RAL colour K17.12.05 1.4. Adjustments K17.12.06 1.5. Installation K17.12.07 2. OPTIC door closer TS51B, TS51G with slide arm...k17.12.08 2.1. General K17.12.08 2.2. Optic door closer TS51 in stainless steel or RAL colour K17.12.09 2.3. Adjustments K17.12.10 2.4. Accessories K17.12.11 2.5. Installation door closer n TS51B K17.12.13 2.6. Installation door closer n TS51G K17.12.14 3. OPTIC door closer TS61B, TS61G with slide arm...k17.12.15 3.1. General K17.12.15 3.2. Optic door closer TS61 in stainless steel or RAL colour K17.12.16 3.3. Adjustments K17.12.17 3.4. Accessories K17.12.18 3.5. Installation door closer n TS61B K17.12.20 3.6. Installation door closer n TS61G K17.12.21 4. Floor door closers BTS(F) 843, BTS(F) 844...K17.12.22 4.1. General K17.12.22 4.2. Accessories K17.12.23 4.3. Adjustments K17.12.24 4.4. Installation floor door closer and accessories K17.12.25 4.5. Installation example and preparations K17.12.26 k17.12.02

1. OPTIC door closer TS40(V) with scissor arm 1.1. Door closer with standard arm TS40 General The door closers combine reliability and functionality with an attractive and timeless design. The door closers offer solutions for residential and public buildings. Suitable for both standard as well as heavy internal and external doors. Also suitable for smoke and fire doors. k17.12 Technical characteristics The door closers are tested according to the standard EN 1154 A and are CE marked according to the EU directives. Classification code : 4 8 5 2 1 1 4 (standard installation), 3 8 5 2 1 1 4 (upside down installation). Closing force: EN 2-5 Maximum vent width: 1250 mm. Door closer dimensions: see drawing. Door closer weight: 1.490 kg. Materials: aluminium, cover in stainless steel. Available in the following finishes: RAL colour on request: see page K17.12.05 white grey black Advantages Simple and quick installation. One version for both left hand and right hand doors and for installation on the hinge side as well as the hinge-opposite side. Concealed fixing by means of a sliding cover plate. The door closer is provided with: Continuously adjustable closing force Continuously adjustable closing speed Continuously adjustable latching action Continuously adjustable backcheck k17.12.03

1.2. Door closer with hold open arm TS40V General and technical characteristics Similar to the door closer TS40 with standard arm. With a hold open arm the door can be temporarily held open in any position, for example in case of removals. Attention: the hold open arm is not allowed on fire-resisting doors! Adjustment hold open arm 1 Loosen screw 2 Open the door and tighten the screw 3 The hold open cam turns now 4 5 Adjustment 6 screw for bullet tension Hold open bullet Click k17.12.04

1.3. Optic door closer TS40(V) in RAL colour General The door closer itself is supplied in standard grey. The special cover and the arm are available polyester powder coated in more than 450 RAL colours. Door closer TS40 with standard arm Door closer TS40V with hold open arm k17.12.05

1.4. Adjustments Closing force (4) Closing force Maximum Adjustment EN vent width screw turns Adjustable closing force of EN 2-5. 2 850 mm -5 The closing force is continuously adjustable by 3 950 mm 0 means of screw 4 at the side of the door closer. 4 1100 mm 3 Notes: The door closer is supplied with closing force EN 3. Screw turns = number of rotations of the adjustment screw. 5 1250 mm 6 Adjustment afterwards: first turn the screw completely in 1 direction, then adjust. The closing force is adjusted in accordance with the application: vent width weather conditions open in or open out door Position of the arm fixing piece: Closing force 5 Closing force 2, 3, 4 Latching action (1) Adjustable latching action active from 0 to 7. The latching action is continuously adjustable by means of screw 1 on the front of the door closer. The latching action increases the closing speed and thus closing force so that the door will certainly be closed. For example to overcome gasket pressure, the latch of the lock or air pressure. Closing speed (2) Adjustable closing speed, nearly independent from temperature fluctuations. The closing speed is continuously adjustable by means of screw 2 on the front of the door closer. Backcheck (3) Adjustable backcheck which reduces the opening speed starting at an opening angle of 70. The backcheck is continuously adjustable by means of screw 3 on the front of the door closer. When the door is violently opened on purpose, by accident or by wind, the backcheck provides protection of the wall and the door against damage. k17.12.06

1.5. Installation Hinge side Pilot holes for screws Left hand = illustrated Right hand = opposite view Same installation for both a left hand and right hand door. Opening range: see illustration right. 1 = latching action: from 7 to 0 2 = closing speed: from 180 to 0 3 = backcheck: from 70 to 180 Hinge-opposite side Pilot holes for screws Left hand = illustrated Right hand = opposite view Same installation for both a left hand and right hand door. Opening range: see illustration right. 1 = latching action: from 7 to 0 2 = closing speed: from 170 to 0 3 = backcheck: from 70 to 170 The maximum opening angle of 170 varies according to the profile depth and the hinge type. Note: a door stop as opening restrictor is recommended! k17.12.07

2. OPTIC door closer TS51B, TS51G with slide arm 2.1. General Suitable for standard internal and external doors. Also suitable for smoke and fire doors. The door closers with slide arm TS51 combine reliability and functionality with an attractive and timeless design. The door closers offer solutions for residential and public buildings. Dependent on the installation situation, a B-type or G-type must be chosen. See technical characteristics. Technical characteristics The door closers are tested according to the standard EN 1154 A and are CE marked according to the EU directives. Classification code : 4 8 4 1 1 1 3 (TS51B), 3 8 4 1 1 1 4 (TS51G). Closing force: EN 1-4 Maximum vent width: 1100 mm. Door closer dimensions: see drawing. Door closer weight: 2.040 kg. Materials: aluminium, cover in stainless steel. Available in the following finishes: RAL colour on request: see page K17.12.09 white grey black Advantages Simple and quick installation. The door closer is provided with: Mounting plate Continuously adjustable closing force Continuously adjustable closing speed Continuously adjustable latching action Continuously adjustable backcheck Installation by means of a concealed mounting plate according to EN 1154 which also serves as drilling jig. Concealed fixing by means of the cover plate which is simply clipped on the door closer. k17.12.08

2.2. Optic door closer TS51 in stainless steel or RAL colour The door closer and the slide arm itself are supplied in standard grey. The special covers for the door closer and for the arm are available: in stainless steel polyester powder coated in more than 450 RAL colours. k17.12.09

2.3. Adjustments Closing force (4) Adjustable closing force of EN 1-4. The closing force is continuously adjustable by means of screw 4 at the side of the door closer. The door closer is supplied with closing force EN 3. The closing force is adjusted in accordance with the application: vent width weather conditions open in or open out door Notes: Screw turns = number of rotations of the adjustment screw. Adjustment afterwards: first turn the screw completely in 1 direction, then adjust. Closing force EN Maximum vent width Adjustment screw turns 1 750 mm -7 2 850 mm -4 3 950 mm 0 4 1100 mm 6 Latching action (1) Adjustable latching action active from 0 to 7. The latching action is continuously adjustable by means of screw 1 on the front of the door closer. The latching action increases the closing speed and thus closing force so that the door will certainly be closed. For example to overcome gasket pressure, the latch of the lock or air pressure. Closing speed (2) Adjustable closing speed, nearly independent from temperature fluctuations. The closing speed is continuously adjustable by means of screw 2 on the front of the door closer. Backcheck (3) Adjustable backcheck which reduces the opening speed starting at an opening angle of 70. The backcheck is continuously adjustable by means of screw 3 on the front of the door closer. When the door is violently opened on purpose, by accident or by wind, the backcheck provides protection of the wall and the door against damage. k17.12.10

2.4. Accessories Hold open device n TS51-3 The mechanical hold open device to hold open doors between 80 and 130 must be ordered separately. For example in case of removal. The hold open device is mounted in the track of the slide arm. Attention: hold open device is not allowed on fire-resisting doors! Remove Slide the connection piece in the right direction! Opening restrictor n TS51-4 Stop mounted in the slide arm to restrict the opening angle of the door. k17.12.11

Fixing set n TS51-5 Separately available fixing set for slide arm. Fixing set n TS51-6 Separately available fixing set for door closer. k17.12.12

2.5. Installation door closer n TS51B Hinge side Left hand = illustrated Right hand = opposite view Pilot holes for screws Same installation for both a left hand and right hand door. Opening range: see illustration right. 1 = latching action: from 7 to 0 2 = closing speed: from 180 to 0 3 = backcheck: from 70 to 180 Hinge-opposite side Left hand = illustrated Right hand = opposite view Pilot holes for screws Same installation for both a left hand and right hand door. Opening range: see illustration right. 1 = latching action: from 7 to 0 2 = closing speed: from 140 to 0 3 = backcheck: from 70 to 140 The maximum opening angle of 140 varies according to the profile depth and the hinge type. Note: a door stop as opening restrictor is recommended! k17.12.13

2.6. Installation door closer n TS51G Hinge side Left hand = illustrated Right hand = opposite view Pilot holes for screws Same installation for both a left hand and right hand door. Opening range: see illustration right. 1 = latching action: from 7 to 0 2 = closing speed: from 180 to 0 3 = backcheck: from 70 to 180 Hinge-opposite side Left hand = illustrated Right hand = opposite view Pilot holes for screws Same installation for both a left hand and right hand door. Opening range: see illustration right. 1 = latching action: from 7 to 0 2 = closing speed: from 140 to 0 3 = backcheck: from 70 to 140 The maximum opening angle of 140 varies according to the profile depth and the hinge type. Note: a door stop as opening restrictor is recommended! k17.12.14

3. OPTIC door closer TS61B, TS61G with slide arm 3.1. General k17.12 Suitable for both standard as well as heavy internal and external doors. Also suitable for smoke and fire doors. The door closers with slide arm TS61 combine reliability and functionality with an attractive and timeless design. The door closers offer solutions for residential and public buildings. Dependent on the installation situation, a B-type or G-type must be chosen. See technical characteristics. Technical characteristics The door closers are tested according to the standard EN 1154 A and are CE marked according to the EU directives. Classification code : 4 8 5 2 1 1 4 (TS61B), 3 8 5 2 1 1 4 (TS61G) Closing force: EN 2-5 Maximum vent width: 1250 mm. Door closer dimensions: see drawing. Door closer weight: 2.380 kg. Materials: aluminium, cover in stainless steel. Available in the following finishes: RAL colour on request: see page K17.12.16 white grey black Advantages Simple and quick installation. The door closer is provided with: Continuously adjustable closing force Mounting plate Continuously adjustable closing speed Continuously adjustable latching action Continuously adjustable backcheck Continuously adjustable delayed action Installation by means of a concealed mounting plate according to EN 1154 which also serves as drilling jig. Concealed fixing by means of the cover plate which is simply clipped on the door closer. k17.12.15

3.2. Optic door closer TS61 in stainless steel or RAL colour The door closer and the slide arm itself are supplied in standard grey. The special covers for the door closer and for the arm are available: in stainless steel polyester powder coated in more than 450 RAL colours. k17.12.16

3.3. Adjustments Closing force (5) Adjustable closing force of EN 2-5. The closing force is continuously adjustable by means of screw 5 at the side of the door closer. The door closer is supplied with closing force EN 3. The closing force is adjusted in accordance with the application: Closing force EN Maximum vent width Adjustment screw turns 2 850 mm -5 vent width 3 950 mm 0 weather conditions 4 1100 mm 7 open in or open out door 5 1250 mm 15 Notes: Screw turns = number of rotations of the adjustment screw Adjustment afterwards: first turn the screw completely in 1 direction, then adjust. Latching action (1) Adjustable latching action active from 0 to 7. The latching action is continuously adjustable by means of screw 1 on the front of the door closer. The latching action increases the closing speed and thus closing force so that the door will certainly be closed. For example to overcome gasket pressure, the latch of the lock or air pressure. Closing speed (2) Adjustable closing speed, nearly independent from temperature fluctuations. The closing speed is continuously adjustable by means of screw 2 on the front of the door closer. Backcheck (3) Adjustable backcheck which reduces the opening speed starting at an opening angle of 70. The backcheck is continuously adjustable by means of screw 3 on the front of the door closer. When the door is violently opened on purpose, by accident or by wind, the backcheck provides protection of the wall and the door against damage. Delayed action (4) Adjustable delayed action which decreases the closing speed between the maximum door opening angle and 70. Because of that it allows extra time for people to pass through the door. The delayed action is continuously adjustable by means of screw 4 on the front of the door closer. k17.12.17

3.4. Accessories Hold open device n TS51-3 The mechanical hold open device to hold open doors between 80 and 130 must be ordered separately. For example in case of removal. The hold open device is mounted in the track of the slide arm. Attention: hold open device is not allowed on fire-resisting doors! Remove Slide the connection piece in the right direction! Opening restrictor n TS51-4 Stop mounted in the slide arm to restrict the opening angle of the door. k17.12.18

Fixing set n TS51-5 Separately available fixing set for slide arm. Fixing set n TS51-6 Separately available fixing set for door closer. k17.12.19

3.5. Installation door closer n TS61B Hinge side Left hand = illustrated Right hand = opposite view Pilot holes for screws Same installation for both a left hand and right hand door. Opening range: see illustration right. 1 = latching action: from 7 to 0 2 = closing speed: from 180 to 0 3 = backcheck: from 70 to 180 4 = delayed action: from 180 to 70 Hinge-opposite side Left hand = illustrated Right hand = opposite view Pilot holes for screws Same installation for both a left hand and right hand door. Opening range: see illustration right. 1 = latching action: from 7 to 0 2 = closing speed: from 140 to 0 3 = backcheck: from 70 to 140 4 = delayed action: from 140 to 70 The maximum opening angle of 140 varies according to the profile depth and the hinge type. Note: a door stop as opening restrictor is recommended! k17.12.20

3.6. Installation door closer n TS61G Hinge side Left hand = illustrated Right hand = opposite view Pilot holes for screws Same installation for both a left hand and right hand door. Opening range: see illustration right. 1 = latching action: from 7 to 0 2 = closing speed: from 180 to 0 3 = backcheck: from 70 to 180 4 = delayed action: from 180 to 70 Hinge-opposite side Left hand = illustrated Right hand = opposite view Pilot holes for screws Same installation for both a left hand and right hand door. Opening range: see illustration right. 1 = latching action: from 7 to 0 2 = closing speed: from 140 to 0 3 = backcheck: from 70 to 140 4 = delayed action: from 140 to 70 The maximum opening angle of 140 varies according to the profile depth and the hinge type. Note: a door stop as opening restrictor is recommended! k17.12.21

4. Floor door closers BTS(F) 843, BTS(F) 844 4.1. General The floor door closers are distinguished by their low installation depth and combine reliability and functionality. The door closers offer solutions for residential and public buildings. Suitable for metal, timber and PVC double action doors. The floor door closers without stop are also suitable for smoke and fire doors. Technical characteristics Door closer Closing force EN Maximum opening angle: 130. Maximum vent width The door closers are tested according to the standard EN 1154:1996 + A1:2002 and are CE marked according to the EU directives. Classification code : BTS 843: 3 8 3 1 1 3 BTS 844: 3 8 4 1 1 3 Top pivot, bottom arm and screws are enclosed in the set. The floor door closer is supplied with stainless steel cover plate. Door closer dimensions: see drawing. Maximum vent weight BTS(F) 843 3 950 mm 105 kg BTS(F) 844 4 1100 mm 150 kg Advantages Available with stop at 90 : type F. Low installation depth. A perfect varying power during the door operation ensures a smooth and easy action. The door closer is provided with: Continuously adjustable closing speed; Continuously adjustable latching action; Continuously adjustable backcheck. The door closers require no maintenance. k17.12.22

4.2. Accessories All accessories are enclosed in the set. Top pivot, steel passivated, with horizontal adjustment of 6 mm. Bottom arm, steel passivated. Stainless steel screws. Frame part top pivot 4x screw M6x15 Din965 Cover plate frame part 2x screw M5x6 Din965 3x screw M5x15 Din965 Vent part top pivot Bottom arm 4x screw M6x25 Din965 k17.12.23

4.3. Adjustments The floor door closer is provided with the following adjustments: Closing speed (1) Adjustable closing speed between 130 and 10, nearly independent from temperature fluctuations. The closing speed is continuously adjustable by means of screw 1. Latching action (2) Adjustable latching action active from 10 to 0. The latching action is continuously adjustable by means of screw 2. The latching action increases the closing speed and thus closing force so that the door will certainly be closed. For example to overcome gasket pressure, the latch of the lock or air pressure. Backcheck (3) Adjustable backcheck which reduces the opening speed starting at an opening angle of 70. The backcheck is continuously adjustable by means of screw 3. When the door is violently opened on purpose, by accident or by wind, the backcheck provides protection of the wall and the door against damage. Positioning The position of the floor door closer can be adjusted in the 3 directions within the cement box: Horizontal adjustment (B): 7 mm Lateral adjustment (D): 10 mm Vertical adjustment (C): 4 mm First loosen the fixing screws A and B to adjust the door closer position. k17.12.24

4.4. Installation floor door closer and accessories Cement box Place the cement box parallel to the door leaf and fix with quick drying cement. The top side of the box is at floor level. Door closer Position the door closer correctly in the cement box. The position of the floor door closer can be adjusted in the 3 directions within the cement box: Horizontal adjustment (B): 7 mm Lateral adjustment (D): 10 mm Vertical adjustment (C): 4 mm First loosen the fixing screws A and B to adjust the door closer position. Tighten the screws again after adjustment. Preparation Make the necessary cut-outs and fixing holes in the frame and vent profile for the installation of the bottom arm and the top pivot: see next page. Note: the cut-out for the connection axis on the top vent profile is only required when the distance between frame part and vent part of the top pivot is smaller than 5 mm. Bottom arm First install the small stainless steel cover plate over the cam of the door closer: see drawing below. Fix the bottom arm on the vent profile with the enclosed screws M6x25 Din965. Vent part top pivot Fix the vent part of the top pivot on the vent profile with the enclosed screws M5x15 Din965. Frame part top pivot Fix the frame part of the top pivot on the frame with the enclosed screws M6x15 Din965. If the profile allows it, a cover plate can be mounted on the frame part with the enclosed screws M5x6 Din965. Install the vent Turn the connection axis of the top pivot to raise it sufficiently by means of adjustment screw S (anti-clockwise). Install the vent gently on the axis of the floor door closer. Open the door and position the hole of the vent part directly below the connection axis. Turn the adjustment screw S clockwise to lower the axis sufficiently. Check whether both parts are properly connected to each other. Adjustment Adjust the top pivot when the vent is not perfectly horizontal. This is possible by turning adjustment screw R (adjustment range +/-3 mm). Adjust the closing speed (1), latching action (2) and backcheck (3) in function of the vent dimensions and weight. Attention: for doors opening up to 130, a door stop must be fitted. Install cover plate Install the stainless steel cover plate on the door closer (holes E) with the enclosed screws in order to provide a dust and watertight finish. k17.12 k17.12.25

4.5. Installation example and preparations Note: ensure that the top centre is properly aligned with the bottom rotation point. Profile dependent Frame profile Profile dependent Only when the distance between frame and vent part is less than 5 mm. Top vent profile Adjustment range Vertical movement of the connection axis Adjustment screw R : horizontal adjustment Adjustment range Adjustment screw S : vertical movement of the connection axis Adjustment range Profile dependent Bottom vent profile k17.12.26