U1602A Handheld Oscilloscopes, 20 MHz



Similar documents
Agilent Technologies 3000 Series Oscilloscopes

DataSheet. SHS800 Series Handheld Digital Oscilloscope SHS820/SHS815/SHS810/SHS806. Application Domain

Handheld Digital Storage Oscilloscopes 2510 Series

NEW PRODUCT ANNOUCEMENT

RIGOL Data Sheet. DS1000E, DS1000D Series Digital Oscilloscopes DS1102E, DS1052E, DS1102D, DS1052D. Product Overview. Applications. Easy to Use Design

DataSheet. SHS1000 Series Handheld Digital Oscilloscope SH1102/SHS1062. Features & Benefits

RIGOL Data Sheet. DS1000E, DS1000D Series Digital Oscilloscopes DS1102E, DS1052E, DS1102D, DS1052D. Product Overview. Applications. Easy to Use Design

Digital Storage Oscilloscopes Models 2540B, 2542B, 2540B-GEN, 2542B-GEN

MODEL INDEX ADS1152CA ADS1102CA ADS1062CA ADS1022C

EXPERIMENT NUMBER 5 BASIC OSCILLOSCOPE OPERATIONS

User s Guide DSO-2150 USB PC Based Digital Oscilloscope Operation Manual

Keysight U2701A/U2702A USB Modular Oscilloscope

Embest DSO2300 USB Oscilloscope

Agilent U1610/20A Handheld Digital Oscilloscope Quick Start Guide

Digital Storage Oscilloscopes TDS2000C Series Datasheet

200 MHz 2[4] Channel Digital Oscilloscope HMO2022 [HMO2024] 150 MHz 2[4] Channel Digital Oscilloscope HMO1522 [HMO1524]

DSO8000E SERIES HANDHELD OSCILLOSCOPE

1587/1577. Insulation Multimeters. Technical Data. Two powerful tools in one.

Table of Contents. SAFETY INSTRUCTION...6 Safety Symbols... 6 Safety Guidelines... 7 Power cord for the United Kingdom... 9

Digital Storage Oscilloscope TBS1000B-EDU Series Datasheet

DSO-1062D/DSO-1102D/DSO-1202D different bandwidths. Digital Oscilloscope User Manual

Analogue/Digital Analogue and Differential Oscilloscopes

OX 7100 Series AR RA NT Y

How To Use A High Definition Oscilloscope

Agilent 34405A Multimeter 5.5 Digit Dual Display, Benchtop DMM More Capabilities at a Value Price. Data Sheet

User Manual. Digital Storage Oscilloscope DSO25 / DSO100. Version No.: V 1.6

AC Measurements Using the Oscilloscope and Multimeter by Mr. David Fritz

User Manual. SDS1000DL/CNL/CML Series. Digital Storage Oscilloscope. Version No.: V 1.0. SIGLENT TECHNOLOGIES Co,.LTD

Fluke 3000 FC Series Test Tools Technical Data

User Manual. TDS 200-Series Digital Real-Time Oscilloscope

AutoRanging Digital MultiMeter

Digital Storage Oscilloscope

Lab 1: The Digital Oscilloscope

DDX 7000 & Digital Partial Discharge Detectors FEATURES APPLICATIONS

Mobile Communications DC Sources W

Analyser-Oscilloscopes

Agilent U1230 Series Handheld Digital Multimeters (DMMs)

AC3200 INTELLIGENT BROADBAND AMPLIFIER

User s Guide. Publication number E June Copyright Agilent Technologies All Rights Reserved. E2697A 1 MΩ Impedance Adapter

Multi-Range Programmable DC Power Supplies 9115 Series

Digital Storage Oscilloscopes

Multi-Function Ground

Fluke 3000 FC Series Test Tools Technical Data

Reading: HH Sections , (pgs , )

Impedance 50 (75 connectors via adapters)

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

NTE2053 Integrated Circuit 8 Bit MPU Compatible A/D Converter

Technical Datasheet Scalar Network Analyzer Model MHz to 40 GHz

Experiment 2 Diode Applications: Rectifiers

Arbitrary/Function Generators AFG3000C Series Datasheet

DDX 7000 & Digital Partial Discharge Detectors FEATURES APPLICATIONS

Fluke 192B/196B-C/199B-C

Digital Clamp-on DMMs with uncompromising performance

PicoScope 2200A Series PC OSCILLOSCOPES WITH ARBITRARY WAVEFORM GENERATOR

Agilent 54621A/22A/24A/41A/42A Oscilloscopes and Agilent 54621D/22D/41D/42D Mixed-Signal Oscilloscopes. User s Guide

UT4000. Series USER MANUAL. Digital Storage Oscilloscope

2000 6½-Digit Multimeter

NI USB-5681 RF Power Meter Specifications

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

Diagnostics Tools. for All Makes of agricultural machinery

USER S MANUAL. Hantek6022BE. V1.0.3

No.1. Digital Multimeter RIGOL TECHNOLOGIES, INC.

User's Guide. True RMS Industrial Multimeter

Agilent 4339B/4349B High Resistance Meters

User s Guide DDS-3X25 USB ARBITRARY FUNCTION GENERATOR

Table of Contents 1. USAGE PRECAUTIONS AND RECOMMENDATIONS GENERAL DESCRIPTION AND FEATURES FIRST TIME OPERATION...9

DC Electronic Loads 8500 series

Agilent N8973A, N8974A, N8975A NFA Series Noise Figure Analyzers. Data Sheet

FREQUENCY RESPONSE ANALYZERS

User's Guide. Integrating Sound Level Datalogger. Model Introduction

How To Test A Computer With A Powerline 2.5 (Powerline) And Powerline (Powerplant) (Powerboard) (Awn) (Ios) (Mini Computer) (Microphone) (Wireless) (

RF Peak Power Analyzer

Power-monitoring unit PowerLogic System. Technical data sheet. Power Meter Series 800

USB-500 Series Stand-Alone, Low-Cost Data Loggers

Agilent E5100A Network Analyzer

Digital Phosphor Oscilloscopes TDS3000C Series


Wahl C50 Calibrator FEATURES

81110A Pulse Pattern Generator Simulating Distorted Signals for Tolerance Testing

ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE Test Method for AC to DC Power Supplies

How To Sell A Talan

R&S ZNC Vector Network Analyzer Specifications

Waveform Monitor Audio & Loudness Logging

DCM555 - Data Communications Lab 8 Time Division Multiplexing (TDM) Part 1 - T1/DS1 Signals

Agilent 8757D Scalar Network Analyzer 10 MHz to 110 GHz

Fluke Digital Multimeters Solutions for every need

AC/DC Power Modules C B. TML Series, 20 & 40 Watt. Features. 20 Watt Models

Digital Storage Oscilloscopes

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

RF Measurements Using a Modular Digitizer

Raptor RXi Ultra-fast scanning Countersurveillance Receiver

MCR-VDC-UI-B-DC. Voltage Transducer for DC Voltages. INTERFACE Data Sheet _en_01. 1 Description

Series AMLDL-Z Up to 1000mA LED Driver

This document lists specifications for the NI PXIe-4139 (NI 4139) precision system sourcemeasure

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

Multi-Range Programmable DC Power Supplies 9115 Series

Transcription:

Products & Services Technical Support Buy Industries About Agilent United States Home >... > Oscilloscopes > U1600A Series handheld oscilloscopes (2 models) > U1602A Handheld Oscilloscopes, 20 MHz Product Status: Currently Orderable Currently Supported Key Specifications 20-MHz Bandwidth 2 channels 200 MSa/s Sampling Rate 125 KB Memory Depth Color Display - 4.5 inch Features Waveform Zoom and Math Functions 6000 count Digital Multimeter Data Logger Capability Connectivity Connectivity Standard: USB 2.0 Full Speed IO Interface Optional Connectivity USB Host Capability with Option 001 - Allows you to connect to a USB Memory Device and download waveforms instantaneously. Note that this option has to be specified when placing an order as it cannot be retrofitted on completed or shipped units. Description The NEW Agilent U1602A handheld digital oscilloscope is a full-featured oscilloscope that offers maximum versatility for current and future needs. The Agilent U1602A model is a dual-channel, 20-MHz oscilloscope that has built-in DMM and recorder functions.

Features Three-in-one solution: Dual channel oscilloscope, True RMS DMM, and Real-Time Data Logger Large 4.5 color LCD display Up to 40 MHz bandwidth with advanced triggering Up to 200 MSa/s sampling rate 125 kilobytes of waveform memory depth 22 automatic scope measurement functions available 6,000-count DMM resolution with built-in measurement functions including voltmeter, ohmmeter, and auxiliary meter Zoom and Dual Waveform Math functions (additional FFT function with four windowing techniques available in U1604A) Full remote control and data transfer via PC Link application software USB 2.0 full-speed interface connectivity Multi-language Quick Help support Introduction The U1600A Series handheld digital oscilloscope has a 4.5-inch LCD color display, which helps to clearly distinguish waveforms between two channels. This U1600A Series provides a high performance troubleshooting and quality assurance tool for technical professionals in the installation, maintenance, service, and automotive industries. The U1600A Series consists of two models: U1602A 20 MHz oscilloscope and U1604A 40 MHz oscilloscope. Each model has a real-time sampling rate of up to 200 MSa/s. Users can use the Dual Waveform Math (DWM) and Fast Fourier Transform (FFT) functions (in the U1604A model) to perform quick waveform analyses in both time and frequency domains. The built-in 6000 resolution count true RMS digital multimeter (DMM) comes with an auto-range feature that gives users the flexibility to perform quick and accurate meter measurements including voltage, resistance, and auxiliary measurements. In addition, the standard versions of the U1600A Series models also contain a data logger function. A scope, true RMS DMM, a real-time data logger in one instrument The U1600A Series is a robust, high performance and reliable handheld waveform and meter measurement tool for today s challenging industrial environments. Not only do these instruments provide fully featured oscilloscope functions, but also a 6,000-count true RMS DMM with real-time data logger. The DMM measurement functions include a voltmeter (for DC voltage, AC voltage and true RMS AC + DC voltage measurements), an ohmmeter (for 2-wire resistance, capacitance, diode and continuity tests), and an auxiliary meter (for temperature, ampere measurement). 2

U1600A Series Features Oscilloscope Mode The U1600A Series handheld digital oscilloscope offers the following standard and advanced features to make your analysis and troubleshooting tasks easier and faster. Deep memory The U1600A Series has 125 kilobytes of memory depth. Autoscale Autoscale enables the instruments to quickly display any active signals, and automatically adjust the vertical and horizontal settings with trigger control for best-possible signal display. Dual Waveform Math (DWM) and Fast Fourier Transform (FFT) The U1600A Series offers analysis functions including addition and subtraction for DWM, as well as FFT with four windowing techniques (Rectangular, Hanning, Hamming and Blackman-Harris). The FFT function is only available on the U1604A model. Cursor measurement You can use the cursor function to manually place the readout of the waveform s voltage at any desired vertical or horizontal point. 22 automatic measurements Up to 22 automatic measurements are available. You can carry out and display four different measurements simultaneously. Advanced triggering Advanced triggering includes edge, pulse width, pattern, and video functionality to help you isolate the signal you want to see. Easy connectivity The PC Link application software is bundled with the purchase of any U1600A Series handheld digital oscilloscope. This software provides flexibility for data collection, storage and documentation needs via USB connectivity. Save and recall waveform and setup memories Up to 10 waveforms and configuration setups can be stored in the instrument and recalled at any time for future use and reference. Logger Mode The U1600A Series allows you to customize your data logging for any DMM measurement. This sophisticated function allows you to record and consolidate a sequence of data points for data plotting purposes. Digital Multimeter (DMM) Mode Auto-range All meter measurements come in auto-range mode the instruments automatically select the most appropriate measurement range. Voltmeter Voltmeter measurements include DC voltage, AC voltage, and AC + DC voltage with auto-measurement of minimum, maximum, and average values. Ohmmeter Ohmmeter measurements include resistance, capacitance, diode test, and continuity test. The automeasurement of minimum, maximum, and average values applies only to resistance test. Auxiliary meter The auxiliary meter carries out temperature and ampere measurements. The automeasurement of minimum, maximum, and average values are also available in this mode. 5

SCOPE SPECIFICATIONS [1] Vertical System: Scope Channels Bandwidth ( 3 db) DC vertical gain accuracy Scope Channel Triggering Trigger sensitivity SCOPE CHARACTERISTICS [2] Acquisition: Scope Channels Maximum sample rate U1602A: DC to 20 MHz U1604A: DC to 40 MHz 5 mv/div to 20 mv/div: ± 5% full scale 50 mv/div to 100 V/div: ± 3% full scale DC to 5 MHz: 0.8 divisions U1602A: 5 MHz to 20 MHz 1 division U1604A: 5 MHz to 40 MHz 1 division U1602A: 200 MSa/s interleaved, 100 MSa/s each channel (50 s/div to 125 ns/div) U1604A: 200 MSa/s interleaved, 100 MSa/s each channel (50 s/div to 250 ns/div) U1604A: 2.5 GSa/s (125 ns/div to 10 ns/div) 8 bits 125 kilobytes 5 ns Equivalent sample rate Vertical resolution Maximum memory depth Peak detection Average Selectable in average number of 2, 4, 8, 16, 32, 64, 128, 256 Vertical System: Scope Channels Analog channels Bandwidth ( 3 db) AC coupled Rise time Single shot bandwidth Vertical sensitivity Maximum input Offset/Dynamic range Input impedance Coupling Probes Probe attenuation factors Coupling Maximum probe input Channel 1 and Channel 2 simultaneous acquisition U1602A: DC to 20 MHz U1604A: DC to 40 MHz < 10 Hz without probe < 1 Hz with 10 MW 10:1 probe U1602A: < 17.5 ns U1604A: < 8.8 ns U1602A: 20 MHz U1604A: 40 MHz 5 mv/div to 100 V/div (1:1 scope probe) 50 mv/div to 1 kv/div (10:1 scope probe) 500 mv/div to 10 kv/div (100:1 scope probe) CAT III 300 Vrms (up to 400 Hz) from terminal to ground ± 5 div 1 MW I I < 20 pf AC, DC, GND U1560-60001: 1:1 passive probe U1561-60001: 10:1 passive probe U1562-60001: 100:1 passive probe 1x, 10x, 100x 3 Vp-p, ~ 1 khz 1x CAT III 300 VAC 10 x, 100x CAT III 600 VAC [1] All specifications are warranted. Specifications are valid after a 30-minute warm-up period and within a range of ±10 ºC from firmware calibration temperature. [2] All characteristics are typical performance values and are not warranted. Characteristics are valid after a 30-minute warm-up period and within a range of ±10 ºC from firmware calibration temperature. 6

Noise peak-to-peak DC vertical offset accuracy Single cursor accuracy Dual cursor accuracy Horizontal System Range Resolution Reference position Delay range (pre-trigger) Delay range (post-trigger) Analog Dt accuracy Modes RMS Jitter 3% of full scale or 5 mv, whichever is greater ± 0.1% div ± 2 mv ± 0.5% offset value 4% full scale 4% full scale U1602A: 50 ns to 50 s/div U1604A: 10 ns to 50 s/div U1602A: 2 ns U1604A: 400 ps Left, center, right 15 divisions 1000 divisions ± 3% reading ± 0.4% screen Main, XY, Roll 5% of horizontal scale or 5 ns, whichever is higher Trigger System Source Channel 1 and Channel 2 Modes Auto, normal, single Selections Edge, pulse width, pattern, video Edge Trigger on a rising or falling edge of any source Range Level accuracy Trigger sensitivity Coupling Pattern Pulse Width Video Trigger at the beginning of a pattern of high, low levels and rising or falling edge established conditions of AND, OR, NOR and NAND between the channels. 200 ns to 10 s. Trigger when a positive or negative pulse width of any source larger than, less than, equal to or not equal to duration. Video trigger sensitivity: 0.7 division trigger level. Available to both Channel 1 and Channel 2. Analog progressive and interlaced video standards including NTSC, PAL and SECAM. Positive or negative sync pulse polarity. Modes all fields, even fields, odd fields or line 5 263 within a field. ± 4 divisions from center screen ± 0.5 divisions DC to 5 MHz: 0.8 divisions U1602A: 5 MHz to 20 MHz 1 division U1604A: 5 MHz to 40 MHz 1 division DC, AC (< 1 Hz), HF reject (> 50 khz), LF reject (< 30 khz), Noise reject Measurement System Autoscale Automatic measurement Voltage Time Finds and displays all active scope channels, sets edge trigger mode on highest numbered channel, sets vertical sensitivity on scope channel. Requires voltage > 20 mvp-p, 0.5% duty cycle and frequency > 100 Hz. Measurements continuously updated. Peak-to-peak, maximum, minimum, amplitude, top, base, +overshoot, overshoot, preshoot, RMS, mean and one cycle mean. Frequency, period, +width, width, and +duty cycle and duty cycle on any channel. rise time, fall time, delay and phase shift. 7

Cursors Waveform math Manually place readout of horizontal (X, DX) and vertical (Y, DY). CH1 + CH2, CH1 CH2, CH2 CH1 FFT [1] Window Amplitude display Rectangular, Hanning, Hamming, Blackman-Harris Selectable in amplitude displays of 1 db, 2 db, 5 db, 10 db Digital Multimeter Specifications [1] ± (% reading + % range) Funtion Range Frequency, Test Current or Burden Voltage 1 year Tcal ± 5º C DC Voltage 600.0 mv 6.000 V 60.00 V 600.0 V 0.3 + 0.08 0.3 + 0.08 0.3 + 0.08 0.3 + 0.08 AC Voltage 600.0 mv 600.0 V 50 Hz 1 khz 1 khz 30 khz AC + DC Voltage 6.000 V 600.0 V 50 Hz 1 khz 1 khz 30 khz Resistance Capacitance 600.0 W 6.000 kw 60.00 kw 600.0 kw 6.000 MW 60.00 MW 60.00 nf 600.0 nf 6.000 μf 60.00 μf 300.0 μf 1.0 + 0.2 3.0 + 0.2 1.0 + 0.2 3.0 + 0.2 1.0 + 0.2 Diode 1.000 V 0.5 ma 2.0 + 0.08 Auxiliary Meter Specifications ± (% of reading + % of range) Function Range Frequency 1 year Tcal ± 5 ºC Temperature, ºC 600.0 ºC 0.3 + 0.08 6000 ºC 0.3 + 0.08 Temperature, ºF 600.0 ºF 0.3 + 0.08 6000 ºF 0.3 + 0.08 AC Current 60.00 A 50 Hz 1 khz 1.0 + 0.2 600.0 A 50 Hz 1 khz 1.0 + 0.2 DC Current 60.00 A 1.0 + 0.08 600.0 A 1.0 + 0.08 Measurement Characteristics Full scale reading DC voltage, True RMS AC voltage Continuity 6,000-count Maximum input voltage, 600 Vrms CAT II, 300 Vrms CAT III DC coupled input coupling Beeper < 60 W in 600 W range [1] For temperatures between 0 ºC to 18 ºC and 28 ºC to 50 ºC, add 0.1% of reading + 0.02% of range for every degree Celsius. 8

Data Logger Source Digital multimeter measurements Range 10 divisions Record size Up to 8800 data points (with option 001) Time span Auto range 150 seconds to 20 days Time reference Time from start Record method Selectable minimum, maximum and average Display System Display Resolution Control Built-in help system Real-time clock 4.5-inch diagonal color CSTN LCD 320 x 240 pixels Contrast control, infinite persistance on/off Functional help displayed by pressing help button Time and date (user-adjustable) Storage Save/Recall (non-volatile) Up to 10 setups and traces 9

GENERAL CHARACTERISTICS Power Adapter Line voltage range 50/60 Hz, 100 240 VAC Output voltage 12 VDC Battery Ni-MH rechargeable battery pack 7.2 V, 4500 mah Operating time: 4 hours Charging time: 5 hours, measurement unit off Allow ambient temperature during charging: 10 ºC to 40 ºC Operating Environment Temperature Operating full accuracy 0 ºC to 50 ºC Non-operating 20 ºC to 70 ºC Humidity Operating full accuracy to 80% RH at 40 ºC Altitude Operating full accuracy Up to 2000 m Non-operating 15000 m (50000 ft) ESD tolerance ± 4 kv Safety Compliance IEC 61010-1: 2001/EN61010-1: 2001 CSA C22.2 No. 61010-1: 2004 UL 61010-1: 2004 Pollution degree 2 This instrument is rated for indoor use only. Dimensions (HxWxD) 24.1 cm height x 13.8 cm width x 6.6 cm depth Weight 1.5 kg I/O USB 2.0 full-speed client (standard) USB 2.0 full-speed host (option 001) Firmware upgrade through USB. Warranty 3 years DIMENSIONS 13.8 cm 24.1 cm 6.6 cm 10