Digital Storage Oscilloscopes
|
|
|
- Sharyl McDaniel
- 10 years ago
- Views:
Transcription
1 Digital Storage Oscilloscopes TPS2012B TPS2014B TPS2024B Data Sheet FFT Standard on All Models Advanced Triggers to Quickly Capture the Event of Interest Traditional, Analog-style Knobs and Multilanguage User Interface for Easy Operation Quick Setup and Operation with Autoset Menu, Autorange, Waveform and Setup Memories, and Built-in, Context-sensitive Help Backlit Menu Buttons for High Visibility 11 of the Most Critical Automatic Waveform Measurements Features & Benefits 100 MHz and 200 MHz Bandwidths SampleRatesupto2GS/sRealTime 2 or 4 Fully Isolated and Floating Channels, plus Isolated External Trigger 8 Hours of Continuous Battery Operation with Two Batteries Installed, Hot Swappable for Virtually Unlimited Freedom from AC Line Power Optional Power Application Software offers the Broadest Range of Power Measurements at its Price Point Quickly Document and Analyze Measurement Results with OpenChoice Software or Integrated CompactFlash Mass Storage Applications Industrial Power Design, Troubleshooting, Installation, and Maintenance Advanced Electronics Design, Troubleshooting, Installation, and Maintenance Automotive Design and Test Education TPS2000B Series Oscilloscopes for Powerful Productivity from Bench to Field The TPS2000B Series offers a distinctive range of capabilities in an oscilloscope with controls and menus you will find familiar and easy to use. Available in 2- or 4-channel versions, the TPS2000B Series with IsolatedChannel technology provides isolation from ground and isolation between channels allowing you to take measurements with less worry about damaging circuitry. Battery power comes standard, making it a natural choice for field applications. For work on power electronics, optional software integrates commonly needed power system measurements into the instrument, speeding up power analysis and troubleshooting.
2 Data Sheet Input signal and float voltage maximum safety ratings. Four IsolatedChannel inputs and isolated external trigger input for quick, accurate, affordable floating and differential measurements. Make Floating and Differential Measurements Quickly, Accurately, Affordably Unintentionally grounding a circuit under test is a common cause of poor measurement results and circuit damage. Connecting two or more grounded probes can cause ground loops, and if the current is high enough can result in ruined components and equipment. Most importantly, taking floating measurements without the proper instruments and probes can pose a safety hazard. Tektronix IsolatedChannel technology simplifies floating measurements. Unlike ground-referenced oscilloscopes, the TPS2000B input connector shells are isolated from each other and from earth ground. Within the specified 600 V RMS maximum float voltage, IsolatedChannel technology keeps current from flowing between the TPS2000B input BNC shells or from any BNC shell to earth. Different passive probes are available, depending on your application. With the included TPP0201 passive probes, the TPS2000B can measure up to 400 V p-p. However, to meet the safety rating of the TPP0201, the reference lead of the probe must be maintained within 30 V RMS relative to ground. Because of this, the TPP0201 probe is well suited for working on digital and analog circuits in which the maximum voltage never exceeds 30 V RMS. Measurements on power conversion electronics usually require probes with higher voltage ratings. Tektronix offers two passive probes with insulation systems specifically designed for making floating measurements. Optional P5122 probes, when coupled with the TPS2000B, are suitable for making measurements on 480 V RMS devices in Category II environments, with a maximum float voltage of up to 600 V RMS relative to earth ground. With the optional P5120 probe the TPS2000B can measure up to 800 V p-p,witha maximum float voltage within 600 V RMS of ground. With the optional P5120 probe the TPS2000B can measure up to 800 V p-p with a maximum float voltage within 600 V RMS of ground. The P5120 is the best choice for making AC-coupled ripple measurements on high-voltage DC power supplies. Please see Characteristics for complete safety ratings and specifications. Selecting the Right Probes for the Job Safety Rating On-screen Scope/Probe (Attenuation) Maximum Safety Ratings TPS2000B Viewable Signal Reference Float Safety Input Signal Peak-Peak On-screen RMS Voltage Rating* 1 Voltage (Sinusoid centered (Sinusoidcenteredat0V) at 0 V) TPS2000B Input (1X) 600 V RMS CAT II 300 V RMS CAT II 40 V p-p 14.1 V RMS TPP V RMS 300 V RMS CAT II 400 V p-p 141 V RMS P5120 (20X) 600 V RMS CAT II 1000 V RMS CAT II 800 V p-p 282 V RMS P5122* 2 (100X) 600 V RMS CAT II 1000 V RMS CAT II 2828 V p-p 1000 V RMS * 1 Passive probe reference leads have no attenuation so any working voltage or over-voltage transients pass straight through to the scope reference. Thus, a passive probe reference float rating can never exceed the scope reference float rating. * 2 The P5122 probe should not be used for AC-coupled measurements on signals with greater than 300 V DC offset. The P5120 is the recommended probe for measuring ripple on high-voltage DC supplies. 2
3 Digital Storage Oscilloscopes TPS2012B TPS2014B TPS2024B Perform three-phase power measurements of variable frequency drives. Speed the Design and Test of Industrial Power Systems and Circuits From mobile phones to industrial motor drives, power conversion technology has enabled significant advances in size, performance, and energy efficiency. But even the most basic task of viewing a converter s input and output is complicated by multiple voltage references. Multiple references also make it challenging to view signals from control circuits and power circuits at the same time. Using ground-referenced oscilloscopes in these applications, without appropriate differential probes, can damage circuits and produce bad measurements. For debugging power conversion electronics, IsolatedChannel technology reduces the risk of damage and unintended circuit interactions. For performing power system measurements, TPS2PWR1 power application software is available as an option for the TPS2000B. It provides advanced power measurements right on the oscilloscope, at an entry-level price. Conduct harmonic distortion measurements with TPS2PWR1 software. For dialing in the performance of switching components, the power application software adds important measurements to the TPS2000B, including automatic switching loss, dv/dt, and di/dt cursor measurements. For measurements on AC line voltage and for checking the impact on the power distribution system, the power application software shows harmonic content to the 50th harmonic, and provides phase, reactive power consumption, and power factor measurements. With the four-channel TPS2014B or TPS2024B, you can view three-phase voltages or currents. Two power bundles are available, combining probes and measurement software. Each package combines four probes with the TPS2PWR1 power application software, at prices that are lower than if purchased separately. The TPS2PBND combines four P X passive, high-voltage probes with TPS2PWR1 power application software. The TPS2PBND2 combines four P X passive, high-voltage probes with the power application software. 3
4 Data Sheet Capture elusive glitches the first time with Digital Real-Time (DRT) sampling technology. Quickly Debug and Characterize Signals with DRT Sampling Technology Characterize a wide range of signal types on up to four channels simultaneously with the TPS2000B Series Digital Real-Time (DRT) sampling technology. This acquisition technology makes it possible to capture high-frequency events, such as glitches and edge anomalies, that eludes other oscilloscopes in its class, so that you can be sure to get an accurate view of your signal. Easily Analyze and Document Your Measurement Results Quickly reveal signal interference, crosstalk, and the effects of vibration with frequency domain analysis using the TPS2000B Series Fast Fourier Transform (FFT) feature. Then, easily document your measurement results with the integrated CompactFlash mass storage. To capture, save, and analyze your measurement results on your PC, the included OpenChoice PC software can be used. Every TPS2000B Speed documentation and analysis of measurements results with OpenChoice software and integrated CompactFlash mass storage. Series also ships with a free copy of the special Tektronix Edition of National Instrument s LabVIEW SignalExpress software for basic instrument control, data logging, and analysis. The optional Professional Edition of SignalExpress offers over 200 built-in functions that provide additional signal processing, advanced analysis, sweeping, limit testing, and user-defined step capabilities. SignalExpress supports the range of Tektronix bench instruments* 3, enabling you to connect your entire test bench. You can then access the feature-rich tools packed into each instrument from one intuitive software interface. This allows you to automate complex measurements requiring multiple instruments, log data for an extended period of time, time-correlate data from multiple instruments, and easily capture and analyze your results, all from your PC. Only Tektronix offers a connected test bench of intelligent instruments to simplify and speed debug of your complex design. * 3 To see the full range of Tektronix instruments supported by the Tektronix Edition of NI LabVIEW SignalExpress, visit 4
5 Digital Storage Oscilloscopes TPS2012B TPS2014B TPS2024B Enjoy virtually unlimited freedom from an AC power source with hot-swappable batteries. Easily correlate your measurements between bench, lab, and field with the highly portable TPS2000B Series. Correlate Your Measurements from Bench to Lab to Field* 4 Use the TPS2000B Series on your bench, in the lab, or in the field, with the industry s longest continuous battery life 8 hours and beyond in a highly mobile package. Enjoy virtually unlimited freedom from an AC power source with hot-swappable batteries. Optimize Your Productivity The oscilloscope has a front-panel layout that most users will find familiar. Each channel has a dedicated set of scale and position controls. Reduce your measurement time with features like autoset, autorange, automatic measurements, probe check wizard, and context-sensitive help. Backlit menu buttons help you work in a variety of challenging environments from bright daylight to dimly lit areas. Performance You Can Count On In addition to industry-leading service and support, every TPS2000B Series oscilloscope comes backed with a three-year standard warranty. * 4 Please refer to Environmental and Safety specifications. Easily use the oscilloscope even in environments that challenge operation, with features such as analog-style knobs per channel and backlit menu buttons. 5
6 Data Sheet Characteristics TPS2000B Series Electrical Characteristics Feature TPS2012B TPS2014B TPS2024B Isolated Channels Bandwidth* 5 (MHz) Sample Rate (GS/s) per Channel Record Length 2.5k points Display (1/4 VGA LCD) Color Battery Operation Capacity for two hot-swappable battery packs One standard battery pack offers 4 hours of battery operation Optional second battery pack extends battery operation to 8 hours Continuous battery operation is possible by hot-swapping charged batteries Automatic Measurements 11 Isolated External Trigger Input (Impedance Yes isolated) Vertical Resolution 8 bits (normal or with averaging) Vertical Sensitivity 2 mv to 5 V/div on all models with calibrated fine adjustment DC Vertical Accuracy ±3% Vertical Zoom Vertically expand or compress a live or stopped waveform Max Input Voltage (1 MΩ) 300 V RMS CAT II from BNC signal to BNC shell Float Voltage 600 V RMS CAT II from BNC shell to earth ground Position Range 2mVto200mV/div±1.8V >200mVto5V/div±45V Bandwidth Limit 20 MHz Linear Dynamic Range ±5 div Time Base Range 5nsto50 s/div 5nsto50 s/div 2.5 ns to 50 s/div Time Base Accuracy 50 ppm Input Impedance 1MΩ ±2% in parallel with 20 pf Input Coupling AC, DC, GND Horizontal Zoom Horizontally expand or compress a live or stopped waveform FFT Standard RS-232, Centronics-Parallel Ports Standard PC Connectivity Standard Integrated CompactFlash Mass Storage Standard Power Measurements Optional package that offers instantaneous power waveform analysis, waveform analysis, harmonics analysis, switching loss, phase angles, dv/dt and di/dt cursors * 5 Bandwidth is 20 MHz at 2 mv/div, all models. For TPS2024B, 200 MHz bandwidth is typical at 5 mv/div. Bandwidth is 200 MHz at 10 mv/div and above, for operating temperatures from 0 C to 40 C. Bandwidth is 180 MHz for all V/div settings 10 mv/div and above, for operating temperatures from 0 C to 50 C. 6
7 Digital Storage Oscilloscopes TPS2012B TPS2014B TPS2024B Acquisition Modes Mode Peak Detect High-frequency and random glitch capture. Captures glitches as narrow as 12 ns typical using acquisition hardware at all time/div settings from 5 μs/div to 50 s/div Sample Sample data only Average Waveform averaged, selectable: 4, 16, 64, 128 Single Sequence Use the Single Sequence button to capture a single triggered acquisition sequence at a time Scan/Roll Mode At acquisition time-base settings of 100 ms/div Trigger System (Main Only) Characteristic Trigger Modes Trigger Types Trigger Edge (Rising or falling) Video Pulse Width (or glitch) Trigger Source Characteristic 2-channel Models 4-channel Models Trigger View Auto, Normal, Single Sequence Conventional level-driven trigger. Positive or negative slope on any input. Coupling Selections: AC, DC, Noise Reject, HF Reject, LF Reject Trigger on all lines or individual line, odd/even or all fields from composite video, or broadcast standards (NTSC, PAL, SECAM) Trigger on a pulse width less than, greater than, equal to, or not equal to a selectable time limit ranging from 33 ns to 10 s CH1, CH2, Ext, Ext/5, Ext/10 CH1, CH2, CH3, CH4, Ext, Ext/5, Ext/10 Displays trigger signal while trigger view button is depressed. Trigger Signal Frequency Readout Provides a frequency readout of the trigger source with 6-digit resolution. Cursors Characteristic Types Voltage, Time Measurements ΔT, 1/ΔT (frequency), ΔV, dv/dt* 6,di/dt* 6 Measurement System Characteristic Automatic Waveform Measurements Waveform Processing Characteristic Operators FFT Period, Frequency, +Width, Width, Rise Time, Fall Time, Max, Min, Peak-to-Peak, Mean, Cycle RMS Add, Subtract, Multiply, FFT Windows: Hanning, Flat Top, Rectangular; 2048 sample points Sources 2-channel Models CH1 CH2, CH2 CH1, CH1 + CH2, CH1 CH2 4-channel Models CH1 CH2, CH2 CH1, CH3 CH4, CH4 CH3, CH1 + CH2, CH3 + CH4, CH1 CH2, CH3 CH4 Autoset Menu Single-button, automatic setup of all channels for vertical, horizontal, and trigger systems, with undo autoset Autorange Allows the user to change test points without resetting the oscilloscope Autoset Menu for Multiple Signal Types Signal Type Square Wave Sine Wave Video (NTSC, PAL, SECAM) Autoset Menu Choices Nonvolatile Storage Characteristic Nonvolatile Storage Reference Waveform Display Waveform Storage Setups Screen Images Save All Display Characteristics Characteristic Display Interpolation Display Types Persistence Format Single Cycle, Multicycle, Rising or Falling Edge Single Cycle, Multicycle, FFT Spectrum Video (NTSC, PAL, SECAM) Field: All, Odd, or Even Line: All or Selectable Line Number CompactFlash upto2gb Two 2500 point reference waveforms 96 or more reference waveforms per 8 MB 4000 or more front-panel setups per 8 MB 128 or more screen images per 8 MB (the number of images depends on file format selected) 12 or more Save All operations per 8 MB. A single Save All operation creates 2 to 9 files (setup, image, plus one file for each displayed waveform) 1/4 VGA Active TFT Color LCD display Sin (x)/x Dots, vectors Off, 1 sec, 2 sec, 5 sec, Infinite YT and XY 7
8 Data Sheet I/O Interface Characteristic RS-232 Port (Standard) 9-pin DTE RS-232 Full talk/listen modes. Control of all modes, settings, and Programmability measurements. Baud rate up to 19,200 Mass Storage Accepts any Type 1 CompactFlash card,uptoand CompactFlash including 2 GB (card not included) Memory Built-in Clock/Calendar OpenChoice PC Seamless connection from oscilloscope to PC through Communications RS-232. Software Transfer and save settings, waveforms, measurements, and screen images. Includes a Windows desktop data transfer application in addition to convenient Microsoft Word and Excel toolbar add-ins Printer Port (Standard) Centronics-type Parallel Graphics File TIFF, PCX (PC Paint Brush), BMP (Microsoft Windows), Formats EPS (Encapsulated Postscript), and RLE Printer Formats Bubble Jet, DPU-411, DPU-412, DPU-3445, Thinkjet, Deskjet, Laser Jet, Epson Dot (9- or 24-pin), Epson C60, Epson C80 Layout Landscape and Portrait * 6 Requires TPS2PWR1 power application package. Environmental and Safety Characteristic Temperature Operating 0 C to +50 C Nonoperating 40 C to +71 C Humidity TPS2000B Series oscilloscopes are not intended for use in wet or damp conditions Operating High: 50 C / 60% RH Low: 30 C / 90% RH Nonoperating High:55 Cto71 C/60%RHmaxwetbulb Low: 30 C to 0 C / <90% RH max wet bulb Altitude Operating Up to3,000m Nonoperating 15,000 m Pollution Degree 2 Do not operate in an environment where conductive pollutants may be present (as defined in IEC :2001) Enclosure Rating IP30 When the CompactFlash card and power analysis software are installed (as defined in IEC60529:2001) Electromagnetic Compatibility Meets the intent of Directive 89/336/EEC. Meets or Exceeds: Australian EMC Framework, demonstrated per Emission Standard AS/NZS /2 Safety UL : CAN/CSA22.2 No : EN : Do not float the TPP0201 probe common lead to >30 V RMS. Use the P5122, P5120 (floatableto600v RMS CAT II) or similarly rated passive, high-voltage probe, or an appropriately rated high-voltage, differential probe when floatingthecommonleadabove30v RMS CAT Ratings Overvoltage Categories Category CAT III CAT II CAT I Examples of Products in this Category Distribution-level mains, fixed installation Local-level mains, appliances, portable equipment Signal levels in special equipment or parts of equipment, telecommunications, electronics Materials TPSBAT battery contains less than 8 grams equivalent Lithium. Physical Characteristics INSTRUMENT Dimensions mm in. Width Height Depth Weight kg lb. Instrument Only with 1 battery with 2 batteries INSTRUMENT SHIPPING Package Dimensions mm in. Width Height Depth
9 Digital Storage Oscilloscopes TPS2012B TPS2014B TPS2024B Ordering Information TPS2012B, TPS2014B, TPS2024B Digital Storage Oscilloscopes. Standard Accessories Accessory Probes Battery (1) USB to RS-232 Cable OpenChoice PC Connectivity Software NI SignalExpress Tek Edition Software Documentation AC Adapter with Power Cord NIM/NIST-Traceable Certificate of Calibration Front Protective Cover TPP MHz, 10X passive probes (one per channel) Lithium-ion battery with fuel gauge for 4-hour battery life. Two batteries required for 8 hours of continuous battery operation A cable to connect to a PC USB port through the RS-232 port on the backside of the scope A collection of programs that enable fast and easy communication between MS Windows PCs and TPS2000B Series oscilloscopes A program that enables easy communication between PC-based NI SignalExpress software and TPS2000B Series oscilloscopes User Manual (please see below for available language options) Recommended Accessories Accessory TPS2PBND2 Power bundle for TPS2000B oscilloscopes. Includes (4) P5122 passive, 100X high-voltage probes and TPS2PWR1 power measurement and analysis software TPS2PWR1 Power measurements application package. Instantaneous power waveform analysis, waveform analysis, harmonics analysis, switching loss, phase angles, dv/dt and di/dt cursors WSTRO WaveStar software; Microsoft Windows application for waveform capture, analysis, documentation, and control from your PC. Provides enhanced oscilloscope data measurement, analysis, remote setup and charting features TPSBAT Additional battery TPSCHG Battery charger AC2100 Soft case for carrying instrument HCTEK4321 Hard case for carrying instrument (requires AC2100) xx Service Manual English only xx Programmer Manual English only Recommended Probes Accessory A A, 5-50 khz AC current probe/bnc A A, 100 khz AC/DC current probe/bnc P5122* MHz passive 100X high-voltage probe P5205 High-voltage active differential probe (1300 V p-p, 100 MHz) (1103 power supply required) P5210 High-voltage active differential probe (5600 V p-p,50mhz) (1103 power supply required) CT2 2.5 A, 200 MHz AC current probe TCP A, 50 MHz AC/DC current probe (1103 power supply required) TCP303/TCPA A, 15 MHz AC/DC current probe/amplifier TCP305/TCPA A, 50 MHz AC/DC current probe/amplifier TCP312/TCPA A, 100 MHz, DC/AC current probe/amplifier TCP404XL/TCPA A, 2 MHz AC/DC current probe/amplifier * 2 The P5122 probe should not be used for AC-coupled measurements on signals with greater than 300 V DC offset. The P5120 is the recommended probe for measuring ripple on high-voltage DC supplies. International Power Plugs Option Opt. A0 Opt. A1 Opt. A2 Opt. A3 Opt. A5 Opt. A6 Opt. A10 Opt. A11 Opt. A12 Opt. A99 Accessory Cables Cable xx xx xx xx North America power Universal Euro power United Kingdom power Australia power Switzerland power Japan power China power India power Brazil power No power cord or AC adapter RS-232, 9-Pin Female to 25-Pin Male, 4.6 m (15 ft.), for modems RS-232, 9-Pin Female to 9-Pin Female, null modem, for computers RS-232, 9-Pin Female to 25-Pin Female, null modem, for computers Centronics, 25-Pin Male to 36-Pin Centronics, 2.4 m (8 ft.), for parallel printer interfaces International User Manual Language Options Translated front-panel overlay included with its respective user manual. Option Opt. L0 Opt. L1 Opt. L2 Opt. L3 Opt. L4 Opt. L5 Opt. L6 Opt. L7 Opt. L8 Opt. L9 Opt. L10 English ( xx) French ( xx) Italian ( xx) German ( xx) Spanish ( xx) Japanese ( xx) Portuguese ( xx) Simplified Chinese ( xx) Traditional Chinese ( xx) Korean ( xx) Russian ( xx) 9
10 Data Sheet Warranty Information Three-year warranty covering all labor and parts, excluding probes and accessories. Speed Product Development with Best-in-Class Price/Performance The extensive Tektronix portfolio of proven, state-of-the-art stimulus, probing, acquisition, and analysis tools simplify and speed each phase of product design from power-on andverification, through debug and validation, to characterization and test to enable you to race products to your customers when they need them, if not before. Tektronix Support Completes the Solution Anytime you need support, anywhere in the world, depend on Tektronix Support to give you the lowest possible exposure to inconvenience, delay, or disruption of operations. Unsurpassed technical expertise and experience with 24-hour response to technical questions Industry-leading turnaround service time 90-day unconditional service warranty No fine print, no exclusions, no surprises Global support in more than 50 countries 10
11 Digital Storage Oscilloscopes TPS2012B TPS2014B TPS2024B 11
12 Data Sheet Contact Tektronix: ASEAN / Australasia (65) Austria * Balkans, Israel, South Africa and other ISE Countries Belgium * Brazil +55(11) Canada Central East Europe and the Baltics Central Europe & Greece Denmark Finland France * Germany * Hong Kong India Italy * Japan 81 (3) Luxembourg Mexico, Central/South America & Caribbean 52 (55) Middle East, Asia, and North Africa The Netherlands * Norway People s Republic of China Poland Portugal Republic of Korea Russia & CIS +7 (495) South Africa Spain * Sweden * Switzerland * Taiwan 886 (2) United Kingdom & Ireland * USA * European toll-free number. If not accessible, call: Updated 10 February 2011 For Further Information. Tektronix maintains a comprehensive, constantly expanding collection of application notes, technical briefs and other resources to help engineers working on the cutting edge of technology. Please visit Copyright Tektronix, Inc. All rights reserved. Tektronix products are covered by U.S. and foreign patents, issued and pending. Information in this publication supersedes that in all previously published material. Specification and price change privileges reserved. TEKTRONIX and TEK are registered trademarks of Tektronix, Inc. All other trade names referenced are the service marks, trademarks, or registered trademarks of their respective companies. 07 Sep MW
Digital Storage Oscilloscopes TDS2000C Series Datasheet
Digital Storage Oscilloscopes TDS2000C Series Datasheet USB 2.0 device port on the rear panel for easy connection to a PC or for direct printing to a PictBridge -compatible printer Includes National Instrument's
Agilent Technologies 3000 Series Oscilloscopes
Agilent Technologies 3000 Series Oscilloscopes Data Sheet The performance and features you need at the industry s lowest price Features: 60 to 200 MHz bandwidths 1 GSa/s maximum sample rate Large 15-cm
TekConnect Adapters. TCA75 TCA-BNC TCA-SMA TCA-N TCA-292MM Data Sheet. Applications. Features & Benefits
TekConnect Adapters TCA75 TCA-BNC TCA-SMA TCA-N TCA-292MM Data Sheet TCA-N TekConnect-to-N DC to 11 GHz (Instrument Dependent) 50 Ω Input (Only) TCA-SMA TekConnect-to-SMA DC to 18 GHz (Instrument Dependent)
Digital Storage Oscilloscopes
Digital Storage Oscilloscopes TDS2000C Series Data Sheet Features & Benefits Key Performance Specifications 200 MHz, 100 MHz, 70 MHz, 50 MHz Bandwidth Models 2- and 4-channel Models Up to 2 GS/s Sample
1.5 GHz Active Probe TAP1500 Datasheet
1.5 GHz Active Probe TAP1500 Datasheet Easy to use Connects directly to oscilloscopes with the TekVPI probe interface Provides automatic units scaling and readout on the oscilloscope display Easy access
NEW PRODUCT ANNOUCEMENT
URRllEN TECHNOLOGY NEW PRODUCT ANNOUCEMENT ADS1000CL+ / CML DSO Series 25MHz ~ 200MHz We are glad to introduce to our global customers our new series of Digital Storage Oscilloscope under ADS1000 CL+ &
High-voltage Differential Probes TMDP0200 - THDP0200 - THDP0100 - P5200A - P5202A - P5205A - P5210A
High-voltage Differential Probes TMDP0200 - THDP0200 - THDP0100 - P5200A - P5202A - P5205A - P5210A BNC interface (P5200A probes) TekVPI interface (TMDP and THDP Series probes) TekProbe interface (P5202A,
Time-Correlated Multi-domain RF Analysis with the MSO70000 Series Oscilloscope and SignalVu Software
Time-Correlated Multi-domain RF Analysis with the MSO70000 Series Oscilloscope and SignalVu Software Technical Brief Introduction The MSO70000 Series Mixed Oscilloscope, when coupled with SignalVu Spectrum
AC/DC Current Measurement Systems TCPA300, TCP312A, TCP305A, TCP303, TCPA400, TCP404XL Datasheet
AC/DC Current Measurement Systems TCPA300, TCP312A, TCP305A, TCP303, TCPA400, TCP404XL Datasheet Low DC drift and noise allows improved low-level current measurements 3rd party safety certification Applications
TekSmartLab TBX3000A, TSL3000B Datasheet
TekSmartLab TBX3000A, TSL3000B Datasheet TekSmartLab is the industry's first network-based instrument management solution for teaching labs that brings a more efficient lab experience. With the TekSmartLab,
Advanced Power Measurement and Analysis Software DPOPWR Datasheet
Advanced Power Measurement and Analysis Software DPOPWR Datasheet Power quality measurements computes THD, True Power, Apparent Power, Power Factor, and Crest Factor. These analysis outputs are shown in
U1602A Handheld Oscilloscopes, 20 MHz
Products & Services Technical Support Buy Industries About Agilent United States Home >... > Oscilloscopes > U1600A Series handheld oscilloscopes (2 models) > U1602A Handheld Oscilloscopes, 20 MHz Product
High-Speed Inter Connect (HSIC) Solution
High-Speed Inter Connect (HSIC) Solution HSIC Essentials Datasheet Protocol Decode Protocol decode Saves test time and resource costs. Designed for use with the MSO/DPO5000, DPO7000C, DPO/DSA/MSO70000C,
RIGOL Data Sheet. DS1000E, DS1000D Series Digital Oscilloscopes DS1102E, DS1052E, DS1102D, DS1052D. Product Overview. Applications. Easy to Use Design
RIGOL Data Sheet DS1000E, DS1000D Series Digital Oscilloscopes DS1102E, DS1052E, DS1102D, DS1052D Product Overview DS1000E, DS1000D series are kinds of economical digital oscilloscope with high-performance.
MODEL INDEX ADS1152CA ADS1102CA ADS1062CA ADS1022C
ADS1000C & CA Series DIGITAL STORAGE OSCILLOSCOPE 25MHz / 60MHz / 100MHz / 150MHz FEATURES 500MSa/s & 1GSa/s Sampling Rate 2 Channels 5.7in LCD Color USB Host/Device: Support USB Printer and USB Flash
Digital Storage Oscilloscope TBS1000B-EDU Series Datasheet
99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Digital Storage Oscilloscope TBS1000B-EDU Series Datasheet The TBS1000B-EDU Digital
DataSheet. SHS800 Series Handheld Digital Oscilloscope SHS820/SHS815/SHS810/SHS806. Application Domain
DataSheet SHS800 Series Handheld Digital Oscilloscope SHS820/SHS815/SHS810/SHS806 Application Domain Outdoor measure Circuit measure Wind power, PV power and other new energy equipment test Automotive
Analogue/Digital Analogue and Differential Oscilloscopes
Analogue/Digital Analogue and Differential Oscilloscopes Metrix oscilloscopes are designed to meet all your signal measurement and analysis needs, for production, laboratory, R&D or professional training
TDS5000B, TDS6000B, TDS/CSA7000B Series Acquisition Modes
TDS5000B, TDS6000B, TDS/CSA7000B Series Acquisition Modes Tektronix oscilloscopes provide several different acquisition modes. While this gives the user great flexibility and choice, each mode is optimized
Arbitrary/Function Generators AFG3000C Series Datasheet
Arbitrary/Function Generators AFG3000C Series Datasheet Applications Electronic test and design Sensor simulation Functional test Education and training Unmatched performance, versatility, intuitive operation,
Digital Phosphor Oscilloscopes TDS3000C Series
Performance You Need at a Price You Can Afford Performance in an Affordable Package The digital phosphor oscilloscopes (DPO) provide you with the performance you need at a price you can afford. Bandwidths
RIGOL Data Sheet. DS1000E, DS1000D Series Digital Oscilloscopes DS1102E, DS1052E, DS1102D, DS1052D. Product Overview. Applications. Easy to Use Design
RIGOL Data Sheet DS1000E, DS1000D Series Digital Oscilloscopes DS1102E, DS1052E, DS1102D, DS1052D Product Overview DS1000E, DS1000D series are kinds of economical digital oscilloscope with high-performance.
DataSheet. SHS1000 Series Handheld Digital Oscilloscope SH1102/SHS1062. Features & Benefits
DataSheet SHS1000 Series Handheld Digital Oscilloscope SH1102/SHS1062 Features & Benefits SHS1000 Series have 2 channels; provide functions as Oscilloscope, Multimeter and Recorder (TrendPlot and waveform
Handheld Digital Storage Oscilloscopes 2510 Series
Data Sheet Handheld Digital Storage Oscilloscopes The handheld digital storage oscilloscopes provide floating measurement and recorder capabilities with a built-in digital multimeter (DMM), all in one
PCI Express Transmitter PLL Testing A Comparison of Methods. Primer
PCI Express Transmitter PLL Testing A Comparison of Methods Primer Primer Table of Contents Abstract...3 Spectrum Analyzer Method...4 Oscilloscope Method...6 Bit Error Rate Tester (BERT) Method...6 Clock
Digital Storage Oscilloscopes Models 2540B, 2542B, 2540B-GEN, 2542B-GEN
Data Sheet Digital Storage Oscilloscopes Models 2540B, 2542B, 2540B-GEN, 2542B-GEN The 2540B, 2542B, 2540B-GEN, and 2542B-GEN dual channel 60 MHz and 100 MHz digital storage oscilloscopes deliver performance
Power-monitoring unit PowerLogic System. Technical data sheet. Power Meter Series 800
Power-monitoring unit PowerLogic System Technical data sheet 2003 Power Meter Series 800 Function and characteristics PB100313 The PowerLogic Power Meter Series 800 offers all the high-performance measurement
DSO-1062D/DSO-1102D/DSO-1202D different bandwidths. Digital Oscilloscope User Manual
DSO-1062D/DSO-1102D/DSO-1202D different bandwidths Digital Oscilloscope User Manual Contents Contents Contents... i Copyright Declaration... iv Chapter 1 Safety Tips... 1 1.1 General Safety Summary...
How To Use A High Definition Oscilloscope
PRELIMINARY High Definition Oscilloscopes HDO4000 and HDO6000 Key Features 12-bit ADC resolution, up to 15-bit with enhanced resolution 200 MHz, 350 MHz, 500 MHz, 1 GHz bandwidths Long Memory up to 250
User s Guide DSO-2150 USB PC Based Digital Oscilloscope Operation Manual
User s Guide DSO-2150 USB PC Based Digital Oscilloscope Operation Manual Certificate of Product Warranty This product s warranty, provided by our company, covers a period of 1 year form the date of purchase.
Agilent BenchVue Software (34840B) Data capture simplified. Click, capture, done. Data Sheet
Agilent BenchVue Software (34840B) Data capture simplified. Click, capture, done. Data Sheet Use BenchVue software to: Visualize multiple measurements simultaneously Easily capture data, screen shots and
Keysight Technologies N1918A Power Analysis Manager and U2000 Series USB Power Sensors. Demo Guide
Keysight Technologies N1918A Power Analysis Manager and U2000 Series USB Power Sensors Demo Guide Introduction This demonstration guide helps you to get familiar with the basic setup and coniguration requirements
2398 9 khz to 2.7 GHz Spectrum Analyzer
Spectrum Analyzers 2398 9 khz to 2.7 GHz Spectrum Analyzer A breakthrough in high performance spectrum analysis, combining cost effectiveness and portability in a new lightweight instrument 9 khz to 2.7
DSO8000E SERIES HANDHELD OSCILLOSCOPE
DSO8000E SERIES HANDHELD OSCILLOSCOPE USER S MANUAL 8072E/8102E/8152E/8202E (V1.0.1) Contents Contents Contents... i Copyright Declaration... iii Chapter 1 Safety Tips... 1 1.1 General Safety Summary...
The Fundamentals of Three-Phase Power Measurements. Application Note
The Fundamentals of - Power Measurements pplication ote pplication ote 0 120 240 360 Figure 1. -phase voltage wavefm. Figure 2. -phase voltage vects. 100Ω 100Ω Figure 4. -phase supply, balanced load -
DDX 7000 & 8003. Digital Partial Discharge Detectors FEATURES APPLICATIONS
DDX 7000 & 8003 Digital Partial Discharge Detectors The HAEFELY HIPOTRONICS DDX Digital Partial Discharge Detector offers the high accuracy and flexibility of digital technology, plus the real-time display
What is the difference between an equivalent time sampling oscilloscope and a real-time oscilloscope?
What is the difference between an equivalent time sampling oscilloscope and a real-time oscilloscope? Application Note In the past, deciding between an equivalent time sampling oscilloscope and a real
Agilent E5100A Network Analyzer
Agilent E5100A Network Analyzer Data Sheet These specifications are the performance standards or limits against which the instrument is tested. When shipped from the factory, the E5100A meets the specifications
Multi-Range Programmable DC Power Supplies 9115 Series
Data Sheet 1200 W Multi-Range DC Power Supplies Features & Benefits Any 9115 series model can replace several supplies on your bench or in your rack. Unlike conventional supplies with fixed output ratings,
User Manual. Digital Storage Oscilloscope DSO25 / DSO100. Version No.: V 1.6
User Manual Digital Storage Oscilloscope DSO25 / DSO100 Version No.: V 1.6 I Declaration Copyright Eleshop. All rights reserved. Contents in this Manual are not allowed to copy, extract and translate before
Agilent E363xA Series Programmable DC Power Supplies. Data Sheet
Agilent E363xA Series Programmable DC Power Supplies Data Sheet Reliable Power, Repeatable Results Single and triple output 80 W to 200 W output power Dual range output Low noise and excellent regulation
User Manual. TDS 200-Series Digital Real-Time Oscilloscope 071-0398-03
User Manual TDS 200-Series Digital Real-Time Oscilloscope 071-0398-03 This document supports firmware version FV:v1.00 and above. www.tektronix.com Copyright Tektronix, Inc. All rights reserved. Tektronix
PRODUCT DATA. PULSE WorkFlow Manager Type 7756
PRODUCT DATA PULSE WorkFlow Manager Type 7756 PULSE WorkFlow Manager Type 7756 provides a range of tools for automating measurement and analysis tasks performed with Brüel & Kjær PULSE. This makes it particularly
Embest DSO2300 USB Oscilloscope
Embest DSO2300 USB Oscilloscope - 8-bit, 100Ms/s, 50MHz, 2-channel USB1.1/2.0 Compatible Digital Storage Oscilloscope - Multi-functions Including Logic Analyzer, Spectrum Analyzer (FFT), Record & Playback
Agilent 4339B/4349B High Resistance Meters
Agilent 4339B/4349B High Resistance Meters Technical Overview Within Budget Without Compromise Introducing the Agilent Technologies 4339B and 4349B High Resistance Meters Used for Making Ultra- High Resistance
Agilent 87421A/87422A Power Supply
Agilent 87421A/87422A Power Supply Technical Overview Designed specifically for Agilent Technologies microwave system amplifiers Bias cable permits remote placement Compact size for easy system integration
Keysight M9485A PXIe Multiport Vector Network Analyzer. Configuration Guide
Keysight M9485A PXIe Multiport Vector Network Analyzer Configuration Guide 02 Keysight M9485A PXIe Multiport Vector Network Analyzer - Configuration Guide Ordering Guide The following steps will guide
e*scope Remote Control Puts Network-Connected Oscilloscope on Your PC Desktop
e*scope Remote Control Puts Network-Connected Oscilloscope on Your PC Desktop Easy to Use Web-based Remote Control Imagine an oscilloscope that you can connect to your prototype in the lab, then operate
Multi-Range Programmable DC Power Supplies 9115 Series
Data Sheet Multi-Range Programmable DC Power Supplies 1200 W / 3000 W Multi-Range DC Power Supplies Features & Benefits Any model can replace several supplies on your bench or in your rack. Unlike conventional
RF and Microwave Power Sensors/Meters Tektronix PSM3000, PSM4000, and PSM5000 Series Data Sheet
RF and Microwave Power Sensors/Meters Tektronix PSM3000, PSM4000, and PSM5000 Series Data Sheet Features & Benefits Key Performance Specifications 8 GHz, 18 GHz, 20 GHz, and 26.5 GHz Models Models Available
plus recording of RMS fluctuations in a single device! MR8870-20 MEMORY HiCORDER Oscilloscope-like waveform observation,
MEMORY HiCORDER MR8870-20 Recorders Oscilloscope-like waveform observation, plus recording of RMS fluctuations in a single device! RMS recording function makes its debut on this device! Enhancing the ultra-compact
Agilent 4338B Milliohm Meter
Agilent 4338B Milliohm Meter 10 µω to 100 kω Technical Overview Introduction Ideal for precise measurements of extremely low resistances using an ac test signal, the Agilent Technologies 4338B suits bench-top
Floating Oscilloscope Measurements And Operator Protection
Technical Brief Floating Oscilloscope Measurements And Operator Protection Introduction Oscilloscope users often need to make floating measurements where neither point of the measurement is at ground (earth)
PicoScope 6000A/B Series
PicoScope 6000A/B Series PC Oscilloscopes User's Guide -1 PicoScope 6000A/B Series User's Guide I Contents 1 Welcome...1 2 Introduction...2 1 Using this guide 2 Safety symbols 3 Safety warnings 4 FCC
NI 9475 8-Channel, 60 V, High-Speed, Sourcing Digital Output Module
OPERATING INSTRUCTIONS AND SPECIFICATIONS NI 9475 8-Channel, 60 V, High-Speed, Sourcing Digital Output Module Français Deutsch ni.com/manuals This document describes how to use the National Instruments
RIGOL. Quick Guide. DS1000CA Series Oscilloscope. Aug. 2011. RIGOL Technologies, Inc.
Quick Guide DS1000CA Series Oscilloscope Aug. 2011 Technologies, Inc. Guaranty and Declaration Copyright 2011 Technologies, Inc. All Rights Reserved. Trademark Information is a registered trademark of
Impedance 50 (75 connectors via adapters)
VECTOR NETWORK ANALYZER PLANAR TR1300/1 DATA SHEET Frequency range: 300 khz to 1.3 GHz Measured parameters: S11, S21 Dynamic range of transmission measurement magnitude: 130 db Measurement time per point:
Power Meter Series 700
PowerLogic power-monitoring units Power Meter Series 700 Technical data sheet 2007 Functions and characteristics E90463 The PowerLogic Power Meter Series 700 offers all the measurement capabilities required
EXPERIMENT NUMBER 5 BASIC OSCILLOSCOPE OPERATIONS
1 EXPERIMENT NUMBER 5 BASIC OSCILLOSCOPE OPERATIONS The oscilloscope is the most versatile and most important tool in this lab and is probably the best tool an electrical engineer uses. This outline guides
How to Guide. Closed Caption Monitoring. WFM6120/7020/7120 & WVR6020/7020/7120 Version 5.0.2 Software
How to Guide Closed Caption Monitoring WFM6120/7020/7120 & WVR6020/7020/7120 Version 5.0.2 Software What Is Closed Captioning? There are a variety of methods to add captioning to the program material depending
DDX 7000 & 8003. Digital Partial Discharge Detectors FEATURES APPLICATIONS
DDX 7000 & 8003 Digital Partial Discharge Detectors The HAEFELY HIPOTRONICS DDX Digital Partial Discharge Detector offers the high accuracy and flexibility of digital technology, plus the real-time display
R&S ZNC Vector Network Analyzer Specifications
ZNC3_dat-sw_en_5214-5610-22_v0300_cover.indd 1 Data Sheet 03.00 Test & Measurement R&S ZNC Vector Network Analyzer Specifications 04.09.2012 13:39:47 CONTENTS Definitions... 3 Measurement range... 4 Measurement
Agilent Television Power Consumption Testing. Application Note
Agilent Television Power Consumption Testing Application Note Introduction Today, there are many types of televisions (TVs) on the market: the cathode ray tube (CRT) TV, liquid crystal display (LCD) TV,
NI 9423. NI C Series Overview DATASHEET. 8-Channel Sinking Digital Input Module
DATASHEET NI 9423 8-Channel Sinking Digital Input Module 8-channel, 100 µs digital input 24 V logic, sinking digital input Compatible with NI CompactDAQ counters 250 Vrms, CAT II isolation 10-position
Keysight Technologies Connecting Data Acquisition Systems to a Wireless Network
Keysight Technologies Connecting Data Acquisition Systems to a Wireless Network Application Brief Test Challenges: Designing heating and air conditioning (HVAC) systems Collecting data on a remotely located
OX 7100 Series AR RA NT Y
PORTABLE Oscilloscope OX 7100 Series W3 YEAR AR RA NT Y Isolated inputs: 600Vac, 850Vdc to ground and channel-to-channel Five complementary tools in one: Oscilloscope, Multimeter, FFT Analyzer, Harmonic
Analyser-Oscilloscopes
Analyser-Oscilloscopes Portable stand-alone instruments from 40 to 100 MHz OX 7042 OX 7062 OX 7102 OX 7104 5 complementary tools in a single instrument: OSCILLOSCOPE, FFT ANALYSER, MULTIMETER/WATTMETER,
Table of Contents. SAFETY INSTRUCTION...6 Safety Symbols... 6 Safety Guidelines... 7 Power cord for the United Kingdom... 9
TABLE OF CONTENTS Table of Contents SAFETY INSTRUCTION...6 Safety Symbols... 6 Safety Guidelines... 7 Power cord for the United Kingdom... 9 GETTING STARTED... 10 Main Features...10 Panel Overview...11
Make Better RMS Measurements with Your DMM
Make Better RMS Measurements with Your DMM Application Note Introduction If you use a digital multimeter (DMM) for AC voltage measurements, it is important to know if your meter is giving you peak value,
DC Electronic Loads 8500 series
Data Sheet DC Electronic Loads 8500 series 2400W 600 W - 1200 W 300 W Versatile & Economical DC Electronic Loads The 8500 series Programmable DC Electronic Loads can be used for testing and evaluating
R&S ZNBT8 Vector Network Analyzer Specifications
ZNBT8_dat-sw_en_3606-9727-22_v0200_cover.indd 1 Data Sheet 02.00 Test & Measurement R&S ZNBT8 Vector Network Analyzer Specifications 20.05.2014 08:39:42 CONTENTS Definitions... 3 Measurement range... 4
How To Test A Computer With A Powerline 2.5 (Powerline) And Powerline (Powerplant) (Powerboard) (Awn) (Ios) (Mini Computer) (Microphone) (Wireless) (
SDS1000D Digital Storage Oscilloscope June 2011 SIGLENT Technologies Co., Ltd. Declaration Copyright SIGLENT Technologies Co.,Ltd. All rights reserved. Contents in this Manual are not allowed to copy,
Quick Connect. quick - simple - efficient. www.g-mw.de
Quick Connect quick - simple - efficient www.g-mw.de Phone: +49 9103 7129-0 Fax: +49 9103 7129-207 Innovative connection technology to plug three single-phase current transformers to multifunctional power
The Next Generation in Automated Oscilloscope Test
The Next Generation in Automated Oscilloscope Test Spanning 100 MHz to 13 GHz, and varying in height from 1U to 8U, Agilent s family of LXI compliant oscilloscopes can accommodate virtually any automated
200 MHz 2[4] Channel Digital Oscilloscope HMO2022 [HMO2024] 150 MHz 2[4] Channel Digital Oscilloscope HMO1522 [HMO1524]
200 MHz 2[4] Channel Digital Oscilloscope HMO2022 [HMO2024] 150 MHz 2[4] Channel Digital Oscilloscope HMO1522 [HMO1524] HMO2024 2 Channel Version HMO2022 Side view 8 Channel Logic Probe HO3508 R 2 GSa/s
Lab 1: The Digital Oscilloscope
PHYSICS 220 Physical Electronics Lab 1: The Digital Oscilloscope Object: To become familiar with the oscilloscope, a ubiquitous instrument for observing and measuring electronic signals. Apparatus: Tektronix
Instructions A622 100 Amp AC/DC Current Probe 070-8883-03
Instructions A622 100 Amp AC/DC Current Probe 070-8883-03 Revision A www.tektronix.com 070888303 Copyright Tektronix, Inc. All rights reserved. Tektronix products are covered by U.S. and foreign patents,
User s Guide DDS-3X25 USB ARBITRARY FUNCTION GENERATOR
User s Guide DDS-3X25 USB ARBITRARY FUNCTION GENERATOR Content General safety summary...1 Introduction...2 Chapter 1 Getting started...3 System Requirements...4 Installing Hardware...5 Installing Software...8
How To Install A Gel Doc Xr+ Camera On A Computer Or Mouse Or Tv (For A Powerbook) With A Zoom Lens (For An Ipa) With An Iphone Or Ipa (For Mac) With The Zoom Lens
Molecular Imager Gel Doc XR+ Installation Guide To install your Gel Doc XR+, perform these seven steps in the following order: 1. Unpack the Gel Doc XR+ system. 2. Install Image Lab software. 3. Set up
Release Notes: PowerChute plus for Windows 95 and Windows 98
: PowerChute plus for Windows 95 and Windows 98 These release notes supplement the User s Guide: PowerChute plus, Version 5.0.2, for Windows 95 and Windows 98 (pc98ug.pdf) and the Installation Guide: PowerChute
FREJA 300 Relay Testing System
Relay Testing System A Megger Group Company FREJA 300 Relay testing system The FREJA 300 relay testing system is a computer-aided relay testing and simulation system. The weight of FREJA 300 is only 15
Video Quality Monitors Sentry Verify Datasheet
Video Quality Monitors Sentry Verify Datasheet Applications Monitor input to hub sites to detect issues during transport IP video network impairment analysis QoS monitoring Digital Program Insertion (DPI)
High Power Programmable DC Power Supplies PVS Series
Data Sheet High Power Programmable DC Power Supplies The PVS10005, PVS60085, and PVS60085MR programmable DC power supplies offer clean output power up to 5.1 kw, excellent regulation, and fast transient
Agilent U1610/20A Handheld Digital Oscilloscope Quick Start Guide
Agilent U1610/20A Handheld Digital Oscilloscope Quick Start Guide Verify that you received the following items in the shipment of your handheld scope: 1 Power cable 1 Li-Ion battery pack, 10.8 V (included
PicoScope 3000 A and B Series
PicoScope 3000 A and B Series PC Oscilloscopes and MSOs User's Guide PicoScope 3000 A and B Series PC Oscilloscopes and MSOs User's Guide I Contents 1 Welcome...1 2 Introduction...2 1 Safety symbols 2
POCKET SCOPE 2. The idea 2. Design criteria 3
POCKET SCOPE 2 The idea 2 Design criteria 3 Microcontroller requirements 3 The microcontroller must have speed. 3 The microcontroller must have RAM. 3 The microcontroller must have secure Flash. 3 The
Physical Layer Compliance Testing for 100BASE-TX
Physical Layer Compliance Testing for 100BASE-TX Application Note Engineers designing or validating the Ethernet physical layer on their products need to perform a wide range of tests, quickly, reliably
Noise Monitoring Software, version 7.0 Types 7802 and 7840
PRODUCT DATA Noise Monitoring Software, version 7.0 Types 7802 and 7840 The basic software packages Noise Monitoring Software Types 7802 and 7840 are the central point in any Brüel & Kjær noise monitoring
Agilent E5063A ENA Series Network Analyzer
Agilent E5063A ENA Series Network Analyzer 100 khz to 4.5/ 8.5/18 GHz Configuration Guide Ordering Guide The following steps will guide you through configuring your E5063A. Standard furnished item Description
PicoScope 2200A Series PC OSCILLOSCOPES WITH ARBITRARY WAVEFORM GENERATOR
2200A Series PC OSCILLOSCOPES WITH ARBITRARY WAVEFORM GENERATOR Benchtop performance in a pocket-sized scope 2 Channels LOW COST 200 mhz bandwidth Up to 1 GS/s sampling rate Arbitrary waveform generator
Installation Qualification/Operational Qualification Protocols and Instructions. Experion Automated Electrophoresis Station and Software
Installation Qualification/Operational Qualification Protocols and Instructions Experion Automated Electrophoresis Station and Software Validation Kit (Catalog #700-7051) Security Edition Software (Catalog
Keysight Technologies N9320B RF Spectrum Analyzer
Keysight Technologies N9320B RF Spectrum Analyzer 9 khz to 3.0 GHz Data Sheet Definitions and Conditions The spectrum analyzer will meet its specifications when: It is within its calibration cycle It has
Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF
Daker DK 1, 2, 3 kva Manuel d installation Installation manual Part. LE05334AC-07/13-01 GF Daker DK 1, 2, 3 kva Index 1 Introduction 24 2 Conditions of use 24 3 LCD Panel 25 4 Installation 28 5 UPS communicator
Keysight N9320B RF Spectrum Analyzer
Keysight N9320B RF Spectrum Analyzer 9 khz to 3.0 GHz Data Sheet 02 Keysight N9320B RF Spectrum Analyzer - Data Sheet Definitions and Conditions Specifications describe the performance of parameters covered
PicoScope 3000 Series
PicoScope 3000 Series A, B and D MSO model oscilloscopes User's Guide PicoScope 3000 Series A/B Oscilloscope & D MSO User's Guide I Contents 1 Introduction...1 1 Safety information...3...4 1 Symbols...5
Agilent U2000 Series USB Power Sensors
Agilent U2000 Series USB Power Sensors Configuration Guide U2000 Series USB Power Sensors U2000A (10 MHz to 18 GHz) U2001A (10 MHz to 6 GHz) U2002A (50 MHz to 24 GHz) U2004A (9 khz to 6 GHz) U2000H (10
3200L 32" Interactive Digital Signage Touch Display
3200L 32" Interactive Digital Signage Touch Display The 3200L Interactive Digital Signage (IDS) display combines precision Elo touch screen technology with a professional-grade, large format LCD panel.
Figure 1: Multiple unsynchronized snapshots of the same sinusoidal signal.
1 Oscilloscope Guide Introduction An oscilloscope is a device used to observe and measure time-dependent electronic signals. It is essentially an enhanced voltmeter which displays a graph of potential
UT4000. Series USER MANUAL. Digital Storage Oscilloscope
UT4000 Series USER MANUAL Digital Storage Oscilloscope UT4000 Series Digital Storage Oscilloscope User Manual General Safety Rules This unit is designed and manufactured strictly in accordance with GB4793
