1 2200A Series PC OSCILLOSCOPES WITH ARBITRARY WAVEFORM GENERATOR Benchtop performance in a pocket-sized scope 2 Channels LOW COST 200 mhz bandwidth Up to 1 GS/s sampling rate Arbitrary waveform generator Advanced digital triggers Persistence display modes USB connected and powered Free software upgrades Mask limit testing Serial bus decoding
2 2200A Series Oscilloscopes Powerful, portable, and versatile The 2200A Series oscilloscopes offer a small, light, modern alternative to bulky benchtop devices. You can now fit a 200 MHz, 1 GS/s instrument easily in your laptop bag! They are perfect for engineers on the move; ideal for a wide range of applications including design, test, education, service, monitoring, fault finding, and repair. Digital triggering Most digital oscilloscopes still use an analog trigger architecture based on comparators. This can cause time and amplitude errors that cannot always be calibrated out. The use of comparators often limits the trigger sensitivity at high bandwidths and can also create a long trigger re-arm delay. A small form factor is not the only benefit of these PC-based scopes. With our 6 software, high-end features such as serial decoding and mask limit testing are included as standard. New functionality is regularly delivered through free upgrades, optimized with the help of feedback from our customers. USB connectivity The USB connection makes printing, copying, saving, and ing your data from the field quick and easy. The high-speed USB interface allows fast data transfer, while USB powering removes the need to carry around a bulky external power supply. Fast sampling The 2200A Series oscilloscopes provide fast real-time sampling rates up to 1 GS/s, equivalent to a timing resolution of only 1 ns. For repetitive signals, equivalent-time sampling (ETS) mode can boost the maximum effective sampling rate up to 10 GS/s, allowing even finer resolution down to 100 ps. All scopes support pre-trigger and post-trigger capture. Arbitrary waveform and function generators All 2200A Series oscilloscopes have a built-in arbitrary waveform generator (AWG). Waveforms can be imported from data files or created and modified using the built-in graphical AWG editor. For over 20 years Pico have been pioneering the use of full digital triggering using the actual digitized data. This reduces trigger errors and allows our oscilloscopes to trigger on the smallest signals, even at the full bandwidth. All triggering is digital, resulting in high threshold resolution within programmable hysteresis and optimal waveform stability. On selected models, the reduced re-arm delay provided by digital triggering, together with segmented memory, allows the capture of events that happen in rapid sequence. At the fastest timebase, rapid triggering can capture a new waveform every 2 microseconds until the buffer is full. The mask limit testing function helps to detect waveforms that fail to meet your specifications. Advanced triggers As well as the standard range of triggers found on most oscilloscopes, the 2200A Series offers one of the best selections of advanced triggers available. These include pulse width, windowed and dropout triggers to help you find and capture your signal quickly. A function generator is also included, with sine, square, triangle, DC level and many more standard waveforms. As well as level, offset and frequency controls, advanced options allow you to sweep over a range of frequencies. Combined with the spectrum peak hold option, this creates a powerful tool for testing amplifier and filter responses.
3 2200A Series Oscilloscopes High signal integrity Most oscilloscopes are built down to a price. s are built up to a specification. Careful front-end design and shielding reduces noise, crosstalk and harmonic distortion. Decades of oscilloscope design experience can be seen in improved pulse response and bandwidth flatness. We are proud of the dynamic performance of our products and publish these specifications in detail. The result is simple: when you probe a circuit, you can trust in the waveform you see on the screen. Color persistence modes Automatic measurements allows you to automatically display a table of calculated measurements for troubleshooting and analysis. Using the builtin measurement statistics you can see the average, standard deviation, maximum and minimum of each measurement as well as the live value. You can add as many measurements as you need on each view. Each measurement includes statistical parameters showing its variability. For information on the measurements available in scope and spectrum modes, see Automatic Measurements in the Specifications table. Advanced display modes allow you to see old and new data superimposed, with new data in a brighter color or shade. This makes it easy to see glitches and dropouts and to estimate their relative frequency. Choose between analog persistence, digital color, or custom display modes. Spectrum analyzer 15 scope mode measurements With the click of a button, you can open a new window to display a spectrum plot of selected channels up to the full bandwidth of the oscilloscope. A comprehensive range of settings gives you control over the number of spectrum bands, window types and display modes. software allows you to display multiple spectrum views with different channel selections and zoom factors, and see these alongside time domain waveforms of the same data. A comprehensive set of automatic frequency-domain measurements can be added to the display, including THD, THD+N, SINAD, SNR and IMD. You can even use the AWG and spectrum mode together to perform swept scalar network analysis. 11 spectrum mode measurements
4 A Series Oscilloscopes Math channels With 6 you can perform a variety of mathematical calculations on your input signals and reference waveforms. Use the built-in list for simple functions such as addition and inversion, or open the equation editor and create complex functions involving trigonometry, exponentials, logarithms, statistics, integrals and derivatives. Mask limit testing allows you to draw a mask around any signal with userdefined tolerances. This has been designed specifically for production and debugging environments, enabling you to compare signals. Simply capture a known good signal, draw a mask around it, and then attach the system under test. will capture any intermittent glitches and can show a failure count and other statistics in the Measurements window. The numerical and graphical mask editors can be used separately or in combination, allowing you to enter accurate mask specifications, modify existing masks, and import and export masks as files. Serial decoding The 2200A Series oscilloscopes include serial decoding capability as standard. The decoded data can be displayed in the format of your choice: In view, In window, or both at once. In view format shows the decoded data beneath the waveform on a common time axis, with error frames marked in red. These frames can be zoomed to investigate noise or distortion. In window format shows a list of the decoded frames, including the data and all flags and identifiers. You can set up filtering conditions to display only the frames you are interested in, search for frames with specified properties, or define a start pattern to signal when the program should list the data. It is also possible to create a spreadsheet to decode the hexadecimal data into user-defined text strings. High-speed data acquisition and digitizing Serial protocols UART/RS-232 SPI I 2 C I 2 S CAN LIN The supplied drivers and software development kit allow you to both write your own software and interface to popular third-party software packages such as LabVIEW and MATLAB. The drivers support data streaming, a mode that captures gap-free continuous data over the USB port directly to the PC s RAM or hard disk at a rate of 1 to 9.6 MS/s, so you are not limited by the size of the scope s buffer memory. Sampling rates in streaming mode are subject to PC specifications and application loading. Custom probe settings The custom probes menu allows you to correct for gain, attenuation, offsets and nonlinearities of probes and transducers, or convert your waveform data to different units such as current, scaled voltage, temperature, pressure, power or db. Definitions can be saved to disk for later use. Definitions for standard Pico-supplied oscilloscope probes and current clamps are built in, but you can also create your own using linear scaling or even an interpolated data table. High-end features as standard Buying a is not like making a purchase from other oscilloscope companies, where optional extras considerably increase the price. With our scopes, high-end features such as resolution enhancement, mask limit testing, serial decoding, advanced triggering, automatic measurements, math channels, XY mode, segmented memory (where available), and a signal generator are all included in the price. To protect your investment, both the PC software and firmware inside the scope can be updated. Pico Technology have a long history of providing new features for free through software downloads. We deliver on our promises of future enhancements year after year, unlike many other companies in the field. Users of our products reward us by becoming lifelong customers and frequently recommending us to their colleagues.
5 The 6 Software : The display can be as simple or as detailed as you need. Begin with a single view of one channel, and then expand the display to include any number of live channels, math channels and reference waveforms. Tools > Serial decoding: Decode multiple serial data signals and display the data alongside the physical signal or as a detailed table. Tools > Reference channels: Store waveforms in memory or on disk and display them alongside live inputs. Ideal for diagnostics and production testing. Tools > Masks: Automatically generate a test mask from a waveform or draw one by hand. highlights any parts of the waveform that fall outside the mask and shows error statistics. Channel options: Offset, scaling, resolution enhancement, custom probes. Auto setup button: Configures the timebase and voltage ranges for stable display of signals. Trigger marker: Drag to adjust trigger level and pre-trigger time. Oscilloscope controls: Controls such as voltage range, scope resolution, channel enable, timebase and memory depth are placed on the toolbar for quick access, leaving the main display area clear for waveforms. Signal generator: Generates standard signals or arbitrary waveforms. Includes frequency sweep mode. Waveform replay tools: automatically records up to 10,000 of the most recent waveforms. You can quickly scan through to look for intermittent events, or use the Buffer Navigator to search visually. Zoom and pan tools: makes it easy to zoom into large waveforms. Either use the zoom-in, zoom-out and pan tools, or click and drag in the Zoom Overview window for fast navigation. Views: is carefully designed to make the best use of the display area. The waveform view is much bigger and of a higher resolution than with a typical benchtop scope. You can add new scope and spectrum views with automatic or custom layouts. Rulers: Each axis has two rulers that can be dragged across the screen to make quick measurements of amplitude, time and frequency. Math channels: Combine input channels and reference waveforms using simple arithmetic, or create custom equations with trigonometric and other functions. Ruler legend: Absolute and differential ruler measurements are listed here. Movable axes: The vertical axes can be dragged up and down. This feature is particularly useful when one waveform is obscuring another. There s also an Auto Arrange Axes command. Trigger toolbar: Quick access to main controls, with advanced triggers in a pop-up window. Automatic measurements: Display calculated measurements for troubleshooting and analysis. You can add as many measurements as you need on each view. Each measurement includes statistical parameters showing its variability. Zoom overview: Click and drag for quick navigation in zoomed views. Spectrum view: View FFT data alongside scope view or independently.
6 2200A Series Oscilloscopes - Specifications PRODUCT SELECTOR MODEL 2204A 2205A 2206A 2207A 2208A Bandwidth (-3 db) 10 MHz 25 MHz 50 MHz 100 MHz 200 MHz Maximum sampling rate 100 MS/s 200 MS/s 500 MS/s 1 GS/s 1 GS/s Buffer memory 8 ks 16 ks 32 ks 40 ks 48 ks Function generator + AWG 100 khz 100 khz 1 MHz 1 MHz 1 MHz DETAILED SPECIFICATIONS VERTICAL Input channels 2 Bandwidth (-3 db) 10 MHz 25 MHz 50 MHz 100 MHz 200 MHz Rise time (calculated) 35 ns 14 ns 7 ns 3.5 ns 1.75 ns Vertical resolution 8 bits Enhanced vertical resolution Up to 12 bits Input ranges ±50 mv, ±100 mv, ±200 mv, ±500 mv, ±1 V, ±2 V, ±5 V, ±10 V, ±20 V Input sensitivity 10 mv/div to 4 V/div (10 vertical divisions) Input coupling AC / DC Input characteristics BNC, 1 MΩ 14 pf BNC, 1 MΩ 13 pf Analog offset range (vertical position adjustment) DC accuracy Overvoltage protection - ±250 mv (50 mv to 200 mv ranges) ±2.5 V (500 mv to 2 V ranges) ±20 V (5 V to 20 V ranges) ±3% of full scale ±100 V (DC + AC peak) HORIZONTAL (TIMEBASE) Maximum sampling rate 1 ch. 100 MS/s 200 MS/s (ChA) 500 MS/s 1 GS/s 1 GS/s (real-time) 2 ch. 50 MS/s 100 MS/s 250 MS/s 500 MS/s 500 MS/s Equivalent sampling rate (ETS) 2 GS/s 4 GS/s 5 GS/s 10 GS/s 10 GS/s Maximum sampling rate (streaming) 1 MS/s 9.6 MS/s Timebase ranges 10 ns to 5000 s/div 5 ns to 5000 s/div 2 ns to 5000 s/div 1 ns to 5000 s/div 500 ps to 5000 s/div Buffer memory (shared between active channels) 8 ks 16 ks 32 ks 40 ks 48 ks Buffer memory (streaming mode) 2 MS per channel in software. 100 MS (shared) in software. Up to available PC memory when using SDK. Maximum buffers (normal triggering) Max. buffers (rapid block triggering) Not available 32 Timebase accuracy ±100 ppm ±50 ppm Sample jitter < 30 ps RMS < 5 ps RMS DYNAMIC PERFORMANCE (typical) Crosstalk (full bandwidth) Better than 200:1 (equal ranges) Better than 400:1 (equal ranges) Harmonic distortion < 50 db at 100 khz, full-scale input SFDR > 52 db at 100 khz, full-scale input Noise < 150 µv RMS (±50 mv range) < 200 µv RMS (±50 mv range) Bandwidth flatness (at scope input) (+0.3 db, 3 db) from DC to full bandwidth TRIGGERING Sources Ch A, Ch B Trigger modes None, auto, repeat, single None, auto, repeat, single, rapid (segmented memory) Advanced triggers Edge, window, pulse width, window pulse width, dropout, window dropout, interval, logic. Trigger types, ETS Rising or falling edge Trigger sensitivity Digital triggering provides 1 LSB accuracy up to full bandwidth In ETS mode, typical 10 mv p-p at full bandwidth Maximum pre-trigger capture 100% of capture size Maximum post-trigger delay 4 billion samples Trigger re-arm time PC-dependent < 2 μs on fastest timebase Maximum trigger rate PC-dependent Up to 32 waveforms in a 64 μs burst
7 Specifications continued A 2205A 2206A 2207A 2208A FUNCTION GENERATOR Standard output signals Sine, square, triangle, DC voltage, ramp, sinc, Gaussian, half-sine Pseudorandom output signals None White noise, PRBS Standard signal frequency DC to 100 khz DC to 1 MHz Sweep modes Up, down, dual with selectable start/stop frequencies and increments Triggering - Free-run or up to 1 billion waveform cycles or frequency sweeps. Triggered from scope trigger or manually. Output frequency accuracy ±100 ppm ±50 ppm Output frequency resolution < 0.01 Hz Output voltage range ±2 V Output adjustments Any amplitude and offset within ±2 V range Amplitude flatness (typical) < 1 db to 100 khz < 0.5 db to 1 MHz DC accuracy ±1% of full scale SFDR (typical) > 55 db at 1 khz full-scale sine wave > 60 db at 10 khz full-scale sine wave Output characteristics Front panel BNC, 600 Ω output impedance Overvoltage protection ±10 V ARBITRARY WAVEFORM GENERATOR Update rate 2 MS/s 20 MS/s Buffer size 4 ks 8 ks Resolution 12 bits Bandwidth > 100 khz > 1 MHz Rise time (10% to 90%) < 2 µs < 120 ns SPECTRUM ANALYZER Frequency range DC to 10 MHz DC to 25 MHz DC to 50 MHz DC to 100 MHz DC to 200 MHz Display modes Magnitude, average, peak hold Windowing functions Rectangular, Gaussian, triangular, Blackman, Blackman-Harris, Hamming, Hann, flat-top Number of FFT points Selectable from 128 to half available buffer memory in powers of 2 MATH CHANNELS Functions x, x+y, x y, x*y, x/y, x^y, sqrt, exp, ln, log, abs, norm, sign, sin, cos, tan, arcsin, arccos, arctan, sinh, cosh, tanh, freq, derivative, integral, min, max, average, peak, delay Operands A, B (input channels), T (time), reference waveforms, constants, Pi AUTOMATIC MEASUREMENTS Scope mode AC RMS, true RMS, cycle time, DC average, duty cycle, falling rate, fall time, frequency, high pulse width, low pulse width, maximum, minimum, peak to peak, rise time, rising rate. Spectrum mode Frequency at peak, amplitude at peak, average amplitude at peak, total power, THD %, THD db, THD plus noise, SFDR, SINAD, SNR, IMD Statistics Minimum, maximum, average and standard deviation SERIAL DECODING Protocols CAN, LIN, I²C, UART/RS-232, SPI, I²S, FlexRay MASK LIMIT TESTING Statistics Pass/fail, failure count, total count DISPLAY Interpolation Linear or sin(x)/x Persistence modes Digital color, analog intensity, custom, or none GENERAL PC connectivity USB 2.0 (USB 1.1 and 3.0 compatible). USB cable included. Power requirements Powered from USB port Dimensions (including connectors) 142 x 92 x 19 mm Weight < 0.2 kg (7 oz) Temperature range Operating: 0 C to 50 C (20 C to 30 C for stated accuracy). Storage: 20 C to +60 C. Humidity range Operating: 5% to 80% RH non-condensing. Storage: 5% to 95% RH non-condensing. Safety approvals Designed to EN :2010 Compliance RoHS, WEEE, and LVD compliant. Tested to meet EN :2006 and FCC Part 15 Subpart B. Software included 6, Windows and Linux SDK, example programs (C, Visual Basic, Excel VBA, LabVIEW) software PC requirements Microsoft Windows XP (SP3), Windows Vista, Windows 7 or Windows 8 (not Windows RT). 32- or 64-bit Languages (manual) Chinese (simplified), English, French, German, Italian, Spanish Languages (software interface) Chinese (simplified & traditional), Czech, Danish, Dutch, English, Finnish, French, German, Greek, Hungarian, Italian, Japanese, Korean, Norwegian, Polish, Portuguese, Romanian, Russian, Spanish, Swedish, Turkish
8 Pack Contents 2200A Series oscilloscope USB cable Two x1/x10 passive probes Quick Start Guide Software and reference CD Matching probes included Two x1/x10 passive probes are included, chosen to match the bandwidth of your scope. Ch A Ch B Arbitrary waveform generator model 2204A 2205A 2206A Probes included Order code 60 MHz probes (2) MI A 150 MHz probes (2) TA A 250 MHz probes (2) TA131 USB port Hand-held oscilloscopes Also available in the 2000 Series, the 2104 and 2105 single channel hand held oscilloscopes are the ultimate in compact design. See for details. Ordering information ORDER CODE DESCRIPTION GBP USD* EUR* PP A 10 MHz oscilloscope 159 $ PP A 25 MHz oscilloscope 249 $ PP A 50 MHz oscilloscope 349 $ PP A 100 MHz oscilloscope 449 $ PP A 200 MHz oscilloscope 599 $ *Prices are correct at the time of publication. Please contact Pico Technology for the latest prices before ordering. For deeper memory, higher or flexible resolution, see the 3000, 4000 and 5000 Series oscilloscopes. UK headquarters: Pico Technology James House Colmworth Business Park St. Neots Cambridgeshire PE19 8YP United Kingdom +44 (0) (0) [email protected] US headquarters: Pico Technology 320 N Glenwood Blvd Tyler Texas United States [email protected] Errors and omissions excepted. Windows is a registered trade mark of Microsoft Corporation in the United States and other countries. Pico Technology and are internationally registered trade marks of Pico Technology Ltd. MM051.en-1. Copyright 2013 Pico Technology Ltd. All rights reserved.
PicoScope 4824 8 CHANNELS 12 BIT RESOLUTION. www.picotech.com HIGH-PRECISION PC OSCILLOSCOPE 256 MS BUFFER MEMORY LOW COST PORTABLE
4824 HIGH-PRECISION PC OSCILLOSCOPE 8 CHANNELS 12 BIT RESOLUTION 256 MS BUFFER MEMORY LOW COST PORTABLE High-performance arbitrary waveform generator SuperSpeed USB 3.0 interface Split-screen waveform
PicoScope 6000A/B Series
PicoScope 6000A/B Series PC Oscilloscopes User's Guide -1 PicoScope 6000A/B Series User's Guide I Contents 1 Welcome...1 2 Introduction...2 1 Using this guide 2 Safety symbols 3 Safety warnings 4 FCC
NEW PRODUCT ANNOUCEMENT
URRllEN TECHNOLOGY NEW PRODUCT ANNOUCEMENT ADS1000CL+ / CML DSO Series 25MHz ~ 200MHz We are glad to introduce to our global customers our new series of Digital Storage Oscilloscope under ADS1000 CL+ &
Oscilloscopes 3 Oscilloscope Overview 6 PicoScope Software 8 PicoScope 2000 Series 12 PicoScope 3000 Series 17 PicoScope 4000 Series 20 PicoScope
TEST & Measurement Product CATALOgue Established in 1991, Pico Technology is a worldwide leader in the field of PC-based test equipment and data acquisition. Our products regularly win industry awards,
USB DrDAQ. USB DrDAQ: Making Data Logging Fun! VERSATI LE DATA AC QU I S ITI O N. www.drdaq.com
YE AR VERSATI LE DATA AC QU I S ITI O N : Making Data Logging Fun! Whether you re a teacher, student, hobbyist or professional the Data Logger gives you an inexpensive entry into the world of PC-based
MODEL INDEX ADS1152CA ADS1102CA ADS1062CA ADS1022C
ADS1000C & CA Series DIGITAL STORAGE OSCILLOSCOPE 25MHz / 60MHz / 100MHz / 150MHz FEATURES 500MSa/s & 1GSa/s Sampling Rate 2 Channels 5.7in LCD Color USB Host/Device: Support USB Printer and USB Flash
How To Use A High Definition Oscilloscope
PRELIMINARY High Definition Oscilloscopes HDO4000 and HDO6000 Key Features 12-bit ADC resolution, up to 15-bit with enhanced resolution 200 MHz, 350 MHz, 500 MHz, 1 GHz bandwidths Long Memory up to 250
RIGOL Data Sheet. DS1000E, DS1000D Series Digital Oscilloscopes DS1102E, DS1052E, DS1102D, DS1052D. Product Overview. Applications. Easy to Use Design
RIGOL Data Sheet DS1000E, DS1000D Series Digital Oscilloscopes DS1102E, DS1052E, DS1102D, DS1052D Product Overview DS1000E, DS1000D series are kinds of economical digital oscilloscope with high-performance.
Agilent Technologies 3000 Series Oscilloscopes
Agilent Technologies 3000 Series Oscilloscopes Data Sheet The performance and features you need at the industry s lowest price Features: 60 to 200 MHz bandwidths 1 GSa/s maximum sample rate Large 15-cm
PicoScope 3000 Series
PicoScope 3000 Series A, B and D MSO model oscilloscopes User's Guide PicoScope 3000 Series A/B Oscilloscope & D MSO User's Guide I Contents 1 Introduction...1 1 Safety information...3...4 1 Symbols...5
PicoScope 3000 A and B Series
PicoScope 3000 A and B Series PC Oscilloscopes and MSOs User's Guide PicoScope 3000 A and B Series PC Oscilloscopes and MSOs User's Guide I Contents 1 Welcome...1 2 Introduction...2 1 Safety symbols 2
Impedance 50 (75 connectors via adapters)
VECTOR NETWORK ANALYZER PLANAR TR1300/1 DATA SHEET Frequency range: 300 khz to 1.3 GHz Measured parameters: S11, S21 Dynamic range of transmission measurement magnitude: 130 db Measurement time per point:
FFT Spectrum Analyzers
FFT Spectrum Analyzers SR760 and SR770 100 khz single-channel FFT spectrum analyzers SR760 & SR770 FFT Spectrum Analyzers DC to 100 khz bandwidth 90 db dynamic range Low-distortion source (SR770) Harmonic,
Analogue/Digital Analogue and Differential Oscilloscopes
Analogue/Digital Analogue and Differential Oscilloscopes Metrix oscilloscopes are designed to meet all your signal measurement and analysis needs, for production, laboratory, R&D or professional training
DataSheet. SHS800 Series Handheld Digital Oscilloscope SHS820/SHS815/SHS810/SHS806. Application Domain
DataSheet SHS800 Series Handheld Digital Oscilloscope SHS820/SHS815/SHS810/SHS806 Application Domain Outdoor measure Circuit measure Wind power, PV power and other new energy equipment test Automotive
Embest DSO2300 USB Oscilloscope
Embest DSO2300 USB Oscilloscope - 8-bit, 100Ms/s, 50MHz, 2-channel USB1.1/2.0 Compatible Digital Storage Oscilloscope - Multi-functions Including Logic Analyzer, Spectrum Analyzer (FFT), Record & Playback
RIGOL Data Sheet. DS1000E, DS1000D Series Digital Oscilloscopes DS1102E, DS1052E, DS1102D, DS1052D. Product Overview. Applications. Easy to Use Design
RIGOL Data Sheet DS1000E, DS1000D Series Digital Oscilloscopes DS1102E, DS1052E, DS1102D, DS1052D Product Overview DS1000E, DS1000D series are kinds of economical digital oscilloscope with high-performance.
U1602A Handheld Oscilloscopes, 20 MHz
Products & Services Technical Support Buy Industries About Agilent United States Home >... > Oscilloscopes > U1600A Series handheld oscilloscopes (2 models) > U1602A Handheld Oscilloscopes, 20 MHz Product
Current Monitoring Kit QUICK START GUIDE
Current Monitoring Kit QUICK START GUIDE Pico Technology EL040 Current Monitoring Kit Quick Start Guide CONTENTS 1 Introduction... 1 2 Kit contents... 3 3 Installation... 3 3.1 Connecting the system together...
MPC 4. Machinery Protection Card Type MPC 4 FEATURES. Continuous on-line Machinery Protection Card
Machinery Protection Card Type FEATURES Continuous on-line Machinery Protection Card Real-time measurement and monitoring using state-of-the-art DSP techniques Fully VME-compatible slave interface Fully
Digital Storage Oscilloscopes Models 2540B, 2542B, 2540B-GEN, 2542B-GEN
Data Sheet Digital Storage Oscilloscopes Models 2540B, 2542B, 2540B-GEN, 2542B-GEN The 2540B, 2542B, 2540B-GEN, and 2542B-GEN dual channel 60 MHz and 100 MHz digital storage oscilloscopes deliver performance
Current Monitoring Kit
Current Monitoring Kit QUICK START GUIDE DO090-6 CONTENTS Issues: 1) 2.10.02 WP A4 format 2) 2.10.02 Added safety warning 3) 17.3.06 Word A5 format. S1: Removed relay modules. S2: Added MI010. S4.1: added
DataSheet. SHS1000 Series Handheld Digital Oscilloscope SH1102/SHS1062. Features & Benefits
DataSheet SHS1000 Series Handheld Digital Oscilloscope SH1102/SHS1062 Features & Benefits SHS1000 Series have 2 channels; provide functions as Oscilloscope, Multimeter and Recorder (TrendPlot and waveform
PicoScope 6 Training Program
PicoScope 6 Training Program DO226-3 Copyright 2014 Pico Technology CONTENTS 1 Quick guide to PicoScope 6... 1 1.1 The PicoScope way... 1 1.2 Signal view... 2 1.3 Timebase... 2 1.4 Voltage range... 3
Arbitrary/Function Generators AFG3000C Series Datasheet
Arbitrary/Function Generators AFG3000C Series Datasheet Applications Electronic test and design Sensor simulation Functional test Education and training Unmatched performance, versatility, intuitive operation,
User s Guide DSO-2150 USB PC Based Digital Oscilloscope Operation Manual
User s Guide DSO-2150 USB PC Based Digital Oscilloscope Operation Manual Certificate of Product Warranty This product s warranty, provided by our company, covers a period of 1 year form the date of purchase.
Building a Simulink model for real-time analysis V1.15.00. Copyright g.tec medical engineering GmbH
g.tec medical engineering GmbH Sierningstrasse 14, A-4521 Schiedlberg Austria - Europe Tel.: (43)-7251-22240-0 Fax: (43)-7251-22240-39 [email protected], http://www.gtec.at Building a Simulink model for real-time
Multi Channel software
Multi Channel software User manual TiePie engineering Copyright c 2014 TiePie engineering. All rights reserved. Revision 1.05, February 2014 Despite the care taken for the compilation of this user manual,
Handheld Digital Storage Oscilloscopes 2510 Series
Data Sheet Handheld Digital Storage Oscilloscopes The handheld digital storage oscilloscopes provide floating measurement and recorder capabilities with a built-in digital multimeter (DMM), all in one
ECONseries Low Cost USB DAQ
ECONseries Low Cost USB Data Acquisition Modules ECONseries Low Cost USB DAQ The ECONseries is a flexible yet economical series of multifunction data acquisition modules. You choose the number of analog
RF Measurements Using a Modular Digitizer
RF Measurements Using a Modular Digitizer Modern modular digitizers, like the Spectrum M4i series PCIe digitizers, offer greater bandwidth and higher resolution at any given bandwidth than ever before.
Performing Amplifier Measurements with the Vector Network Analyzer ZVB
Product: Vector Network Analyzer R&S ZVB Performing Amplifier Measurements with the Vector Network Analyzer ZVB Application Note This document describes typical measurements that are required to be made
DDX 7000 & 8003. Digital Partial Discharge Detectors FEATURES APPLICATIONS
DDX 7000 & 8003 Digital Partial Discharge Detectors The HAEFELY HIPOTRONICS DDX Digital Partial Discharge Detector offers the high accuracy and flexibility of digital technology, plus the real-time display
The Effective Number of Bits (ENOB) of my R&S Digital Oscilloscope Technical Paper
The Effective Number of Bits (ENOB) of my R&S Digital Oscilloscope Technical Paper Products: R&S RTO1012 R&S RTO1014 R&S RTO1022 R&S RTO1024 This technical paper provides an introduction to the signal
User s Guide DDS-3X25 USB ARBITRARY FUNCTION GENERATOR
User s Guide DDS-3X25 USB ARBITRARY FUNCTION GENERATOR Content General safety summary...1 Introduction...2 Chapter 1 Getting started...3 System Requirements...4 Installing Hardware...5 Installing Software...8
One Port Network Analyzer
99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com One Port Network Analyzer 5.4GHz Impendance : 50Ω(75Ωconnectors via adapters) Test
AFG-100/200 series USB Modular Arbitrary Function Generator. Date: Oct, 2014
AFG-100/200 series USB Modular Arbitrary Function Generator Date: Oct, 2014 Outline Product Overview Feature, Advantage and Benefit Comparison Chart Ordering Information 22 Product information AFG-125,
LogicLab s.r.l Via della valle 67 20048 Carate Brianza (MI) Tel. +39 0362 805287 Fax. +39 0362 1914102 www.logiclab.it
Test system DV1512A2NCI Single Current Generator Maximum current 15 Arms in continuity and 30 Arms per 1 s Single Voltage generator 150 Vrms Programmable phase between Current and Voltage Programmable
FREQUENCY RESPONSE ANALYZERS
FREQUENCY RESPONSE ANALYZERS Dynamic Response Analyzers Servo analyzers When you need to stabilize feedback loops to measure hardware characteristics to measure system response BAFCO, INC. 717 Mearns Road
200 MHz 2[4] Channel Digital Oscilloscope HMO2022 [HMO2024] 150 MHz 2[4] Channel Digital Oscilloscope HMO1522 [HMO1524]
200 MHz 2[4] Channel Digital Oscilloscope HMO2022 [HMO2024] 150 MHz 2[4] Channel Digital Oscilloscope HMO1522 [HMO1524] HMO2024 2 Channel Version HMO2022 Side view 8 Channel Logic Probe HO3508 R 2 GSa/s
EXPERIMENT NUMBER 5 BASIC OSCILLOSCOPE OPERATIONS
1 EXPERIMENT NUMBER 5 BASIC OSCILLOSCOPE OPERATIONS The oscilloscope is the most versatile and most important tool in this lab and is probably the best tool an electrical engineer uses. This outline guides
AC Measurements Using the Oscilloscope and Multimeter by Mr. David Fritz
AC Measurements Using the Oscilloscope and Multimeter by Mr. David Fritz 1 Sine wave with a DC offset f = frequency in Hz A = DC offset voltage (average voltage) B = Sine amplitude Vpp = 2B Vmax = A +
RFSPACE CLOUD-IQ #CONNECTED SOFTWARE DEFINED RADIO
CLOUD-IQ #CONNECTED SOFTWARE DEFINED RADIO 1 - SPECIFICATIONS Cloud-IQ INTRODUCTION The Cloud-IQ is a high performance, direct sampling software radio with an ethernet interface. It offers outstanding
A PC-BASED TIME INTERVAL COUNTER WITH 200 PS RESOLUTION
35'th Annual Precise Time and Time Interval (PTTI) Systems and Applications Meeting San Diego, December 2-4, 2003 A PC-BASED TIME INTERVAL COUNTER WITH 200 PS RESOLUTION Józef Kalisz and Ryszard Szplet
NVIDIA GeForce GT630 DP (2GB) PCIe x16 Card Graphics Card. QuickSpecs. Overview. Models. DA - 14380 Worldwide Version 4 November 27, 2012 Page 1
NVIDIA GeForce GT630 DP (2GB) PCIe x16 Graphics Models NVIDIA GeForce GT630 DP (2GB) PCIe x16 Graphics B4J92AA DA - 14380 Worldwide Version 4 November 27, 2012 Page 1 NVIDIA GeForce GT630 DP (2GB) PCIe
Technical Datasheet Scalar Network Analyzer Model 8003-10 MHz to 40 GHz
Technical Datasheet Scalar Network Analyzer Model 8003-10 MHz to 40 GHz The Giga-tronics Model 8003 Precision Scalar Network Analyzer combines a 90 db wide dynamic range with the accuracy and linearity
Mixed Domain Oscilloscopes
Mixed Domain Oscilloscopes A new oscilloscope category.. unique and powerful capabilities Alan Wolke W2AEW RF Applications Engineer Agenda What is a Mixed Domain Oscilloscope (MDO)? Overview of the family
PicoScope 5000 Series (A API)
PicoScope 5000 Series A API PC Oscilloscopes Programmer's Guide PicoScope 5000 Series A API Programmer's Guide I Contents 1 Introduction...1 1 Overview...1...2 2 Minimum PC requirements 3 License agreement...3
R&S ZNBT8 Vector Network Analyzer Specifications
ZNBT8_dat-sw_en_3606-9727-22_v0200_cover.indd 1 Data Sheet 02.00 Test & Measurement R&S ZNBT8 Vector Network Analyzer Specifications 20.05.2014 08:39:42 CONTENTS Definitions... 3 Measurement range... 4
DDX 7000 & 8003. Digital Partial Discharge Detectors FEATURES APPLICATIONS
DDX 7000 & 8003 Digital Partial Discharge Detectors The HAEFELY HIPOTRONICS DDX Digital Partial Discharge Detector offers the high accuracy and flexibility of digital technology, plus the real-time display
Agilent E5100A Network Analyzer
Agilent E5100A Network Analyzer Data Sheet These specifications are the performance standards or limits against which the instrument is tested. When shipped from the factory, the E5100A meets the specifications
Lab 1: The Digital Oscilloscope
PHYSICS 220 Physical Electronics Lab 1: The Digital Oscilloscope Object: To become familiar with the oscilloscope, a ubiquitous instrument for observing and measuring electronic signals. Apparatus: Tektronix
MATLAB Instrument Driver
MATLAB Instrument Driver for PicoScope 5000A/B Series Programmer's Guide MATLAB Instrument Driver for PicoScope 5000 A/B Series Function Guide I Contents 1 Introduction...1 1 License agreement 2 Trademarks
M4i.66xx-x8-16 bit 1.25 GS/s Arbitrary Waveform Generator
M4i.66xx-x8-16 bit 1.25 GS/s Arbitrary Waveform Generator Fast 16 bit arbitrary waveform generator One, two or four channels Versions with 1.25 GS/s and 625 MS/s Ouput signal bandwidth up to 400 MHz Simultaneous
Diagnostics Tools. for All Makes of agricultural machinery
Diagnostics Tools for All Makes of agricultural machinery Including: John Deere New Holland Massey Ferguson Case Fendt Deutz-Fahr Claas McCormick Landini Fiat JCB and many others... www.vapormatic.com
Agilent N8973A, N8974A, N8975A NFA Series Noise Figure Analyzers. Data Sheet
Agilent N8973A, N8974A, N8975A NFA Series Noise Figure Analyzers Data Sheet Specifications Specifications are only valid for the stated operating frequency, and apply over 0 C to +55 C unless otherwise
Accurate Measurement of the Mains Electricity Frequency
Accurate Measurement of the Mains Electricity Frequency Dogan Ibrahim Near East University, Faculty of Engineering, Lefkosa, TRNC [email protected] Abstract The frequency of the mains electricity supply
Digital Storage Oscilloscopes TDS2000C Series Datasheet
Digital Storage Oscilloscopes TDS2000C Series Datasheet USB 2.0 device port on the rear panel for easy connection to a PC or for direct printing to a PictBridge -compatible printer Includes National Instrument's
POCKET SCOPE 2. The idea 2. Design criteria 3
POCKET SCOPE 2 The idea 2 Design criteria 3 Microcontroller requirements 3 The microcontroller must have speed. 3 The microcontroller must have RAM. 3 The microcontroller must have secure Flash. 3 The
Agilent BenchVue Software (34840B) Data capture simplified. Click, capture, done. Data Sheet
Agilent BenchVue Software (34840B) Data capture simplified. Click, capture, done. Data Sheet Use BenchVue software to: Visualize multiple measurements simultaneously Easily capture data, screen shots and
Distributor & Service. Manufacturer. Ing. David Prevorovsky. DYNON INSTRUMENTS Woodinville, WA 98072, USA www.dynoninstruments.com
ELAB-080 User Guide Manufacturer Distributor & Service Ing. David Prevorovsky DYNON INSTRUMENTS Woodinville, WA 98072, USA www.dynoninstruments.com Na brevnovske plani 67, 169 00, Prague 6 Czech Republic
R&S ZNC Vector Network Analyzer Specifications
ZNC3_dat-sw_en_5214-5610-22_v0300_cover.indd 1 Data Sheet 03.00 Test & Measurement R&S ZNC Vector Network Analyzer Specifications 04.09.2012 13:39:47 CONTENTS Definitions... 3 Measurement range... 4 Measurement
Waveform Monitor Audio & Loudness Logging
Waveform Monitor Audio & Loudness Logging PT0800M Data sheet Nov. 201 3 V.1.0 Introducing the PT0800M The PT0800 introduces a unique combination of Audio, Loudness and Waveform monitoring at the highest
ANALYZER BASICS WHAT IS AN FFT SPECTRUM ANALYZER? 2-1
WHAT IS AN FFT SPECTRUM ANALYZER? ANALYZER BASICS The SR760 FFT Spectrum Analyzer takes a time varying input signal, like you would see on an oscilloscope trace, and computes its frequency spectrum. Fourier's
Spectrum Analyzer. Software Instruction Manual
Spectrum Analyzer Software Instruction Manual 700 Chestnut Ridge Road Chestnut Ridge, NY, 10977-6499 Tel: (845) 425-4000 Fax: (845) 578 5985 teledynelecroy.com Spectrum Analyzer Software Instruction Manual
Power-monitoring unit PowerLogic System. Technical data sheet. Power Meter Series 800
Power-monitoring unit PowerLogic System Technical data sheet 2003 Power Meter Series 800 Function and characteristics PB100313 The PowerLogic Power Meter Series 800 offers all the high-performance measurement
Agilent 8904A Multifunction Synthesizer dc to 600 khz
Agilent 8904A Multifunction Synthesizer dc to 600 khz Technical Specifications Build complex waveforms from common signals The Agilent Technologies 8904A Multifunction Synthesizer uses VLSIC technology
CNC-STEP. "LaserProbe4500" 3D laser scanning system Instruction manual
LaserProbe4500 CNC-STEP "LaserProbe4500" 3D laser scanning system Instruction manual 2 Hylewicz CNC-Technik Siemensstrasse 13-15 D-47608 Geldern Fon.: +49 (0) 2831 133236 E-Mail: [email protected] Website:
TDS5000B, TDS6000B, TDS/CSA7000B Series Acquisition Modes
TDS5000B, TDS6000B, TDS/CSA7000B Series Acquisition Modes Tektronix oscilloscopes provide several different acquisition modes. While this gives the user great flexibility and choice, each mode is optimized
US-Key New generation of High performances Ultrasonic device
US-Key New generation of High performances Ultrasonic device US-Key connected to a laptop computer US-Key Ultrasound device single channel Features USB2 High Speed connection Ultralow noise preamplifier
Oscilloscope, Function Generator, and Voltage Division
1. Introduction Oscilloscope, Function Generator, and Voltage Division In this lab the student will learn to use the oscilloscope and function generator. The student will also verify the concept of voltage
APPLICATION NOTE GaGe CompuScope 14200-based Lightning Monitoring System
APPLICATION NOTE GaGe CompuScope 14200-based Lightning Monitoring System Challenge A customer needed to upgrade an older data acquisition unit for a real-time lightning monitoring system. Unlike many lightning
Power Amplifier Gain Compression Measurements
Technical Brief Power Amplifier Gain Compression Measurements GPIB Private Bus Sweep Out Sweep In Pulse In AC Mod Out Blank/Marker Out Blanking In Overview The 1 db gain compression of an amplifier describes
Vibration analysis and monitoring Compact. Powerful. Modern technology.
Vibration analysis and monitoring Compact. Powerful. Modern technology. Maximum performance Vibration measurement with state of the art processor technology Expert Vibro is Delphin Technology's new device
APSYN420A/B Specification 1.24. 0.65-20.0 GHz Low Phase Noise Synthesizer
APSYN420A/B Specification 1.24 0.65-20.0 GHz Low Phase Noise Synthesizer 1 Introduction The APSYN420 is a wideband low phase-noise synthesizer operating from 0.65 to 20 GHz. The nominal output power is
Description: Multiparameter System (4 or 8 channels)
Model MPA4, 8 ch acquisition system with 6 ns time tagging The MPA4 is a Multiparameter Data Acquisition System Description: Multiparameter System (4 or 8 channels) ADC Settings and Presets Dialog The
DSO-1062D/DSO-1102D/DSO-1202D different bandwidths. Digital Oscilloscope User Manual
DSO-1062D/DSO-1102D/DSO-1202D different bandwidths Digital Oscilloscope User Manual Contents Contents Contents... i Copyright Declaration... iv Chapter 1 Safety Tips... 1 1.1 General Safety Summary...
GV-FE420. Visítenos: www.dluxsecurity.com. Cámara IP Fisheye Megapixel
GV-FE420 Introduction The GV FE420 is a fisheye camera that allows you to monitor all angles of a location using just one camera. The distorted hemispherical image of the fisheye camera will be converted
Automotive. Aerospace. bout Us. Defense. Energy. Maritime. Education. Electronics. and more
Automotive Aerospace Defense bout Us Energy Maritime Education Electronics and more 1 2 State-of-the-art Hardware 2~8 Analog Input Channels 1~2 Drive Channel (can be adopted in dualaxis control application)
USB 3.0 CDR Model White Paper Revision 0.5
USB 3.0 CDR Model White Paper Revision 0.5 January 15, 2009 INTELLECTUAL PROPERTY DISCLAIMER THIS WHITE PAPER IS PROVIDED TO YOU AS IS WITH NO WARRANTIES WHATSOEVER, INCLUDING ANY WARRANTY OF MERCHANTABILITY,
User Manual. Digital Storage Oscilloscope DSO25 / DSO100. Version No.: V 1.6
User Manual Digital Storage Oscilloscope DSO25 / DSO100 Version No.: V 1.6 I Declaration Copyright Eleshop. All rights reserved. Contents in this Manual are not allowed to copy, extract and translate before
PT-LB55NT S P E C F I L E. Micro-Portable Wireless LCD Projector. As of February 2006. Specifications subject to change without notice.
Product Number : Product Name : As of February 2006. Specifications subject to change without notice. < > Specifications Power supply Power consumption Optical system CD panel Panel size Display method
WINDAQ Data Acquisition and Playback Software
WINDAQ Data Acquisition and Playback Software Supports All DI-Series Data Acquisition Hardware Disk Streaming and Real Time Display At the Hardware Rate Check Hardware Page For Supported Sampling Rates
A compact, lightweight, portable optical spectrum analyzer for DWDM system installation and maintenance.
A compact, lightweight, portable optical spectrum analyzer for DWDM system installation and maintenance. Bulletin -01E http://www.yokogawa.com/tm/... Visit our website to sign for e-mail updates Compact,
Dayton Audio is proud to introduce DATS V2, the best tool ever for accurately measuring loudspeaker driver parameters in seconds.
Dayton Audio is proud to introduce DATS V2, the best tool ever for accurately measuring loudspeaker driver parameters in seconds. DATS V2 is the latest edition of the Dayton Audio Test System. The original
Analyser-Oscilloscopes
Analyser-Oscilloscopes Portable stand-alone instruments from 40 to 100 MHz OX 7042 OX 7062 OX 7102 OX 7104 5 complementary tools in a single instrument: OSCILLOSCOPE, FFT ANALYSER, MULTIMETER/WATTMETER,
HD141X. Super-sized home entertainment. Bright vivid colours 3000 ANSI Lumens. Full HD 1080p image quality
HD141X Super-sized home entertainment Bright vivid colours 3000 ANSI Lumens Full HD 1080p image quality Dynamic black technology - 23,000:1 contrast ratio Easy connectivity - 2x HDMI and MHL support and
ugrid Testbed. Rein in microgrid complexity. With ease.
ugrid Testbed. Rein in microgrid complexity. With ease. Outsmart the microgrid. ugrid Testbed Ultimate test solution for microgrid control system verification What is a microgrid? Microgrid is a collection
USB TC-08. Temperature Logger. User's Guide. usbtc08.en r7 Copyright 2005-2013 Pico Technology Limited. All rights reserved.
USB TC-08 Temperature Logger User's Guide USB TC-08 User's Guide I Contents 1 Introduction...1...1 1 Overview...1 2 Leg al information...2 3 Safety warning...3 4 Company details 2 Getting Started...4...4
This document lists the specifications for the NI PXIe-5160, 500 MHz digitizer.
DEVICE SPECIFICATIONS NI PXIe-5160 2.5 GS/s, 10-Bit Digitizer This document lists the specifications for the NI PXIe-5160, 500 MHz digitizer. Unless otherwise noted, the following conditions were used
DATENBLATT USB-DIO32HS USB-DIO32HS-OEM. HABEN SIE FRAGEN ODER WÜNSCHEN SIE EIN INDIVIDUELLES ANGEBOT? Unser Team berät Sie gerne persönlich.
DATENBLATT USB-DIO32HS HABEN SIE FRAGEN ODER WÜNSCHEN SIE EIN INDIVIDUELLES ANGEBOT? Unser Team berät Sie gerne persönlich. TELEFON + 49 (0) 81 41/36 97-0 TELEFAX + 49 (0) 81 41/36 97-30 E-MAIL [email protected]
Type-D EEG System for Regular EEG Clinic
Type-D EEG System for Regular EEG Clinic Type-D EEG amplifier Specifications 1. For Type-D Amplifier Input channels: 12/24/36/48 Monopolar EEG + 12channels Bipolar EEG+12 channels PSG. Power supply: Internal
Agilent U2000 Series USB Power Sensors
Agilent U2000 Series USB Power Sensors GSM Timeslot Burst Power Measurement Product Note Table of Content Introduction 2 Measuring GSM Timeslot 4 Signal Overview of Agilent U2000 5 Series USB Power Sensors
UT4000. Series USER MANUAL. Digital Storage Oscilloscope
UT4000 Series USER MANUAL Digital Storage Oscilloscope UT4000 Series Digital Storage Oscilloscope User Manual General Safety Rules This unit is designed and manufactured strictly in accordance with GB4793
OX 7100 Series AR RA NT Y
PORTABLE Oscilloscope OX 7100 Series W3 YEAR AR RA NT Y Isolated inputs: 600Vac, 850Vdc to ground and channel-to-channel Five complementary tools in one: Oscilloscope, Multimeter, FFT Analyzer, Harmonic
PropScope USB Oscilloscope
USB Oscilloscope v1.0 December 2009 Manual by Hanno Sander 3 Table of Contents ForeWord... Part I Welcome... 4 Part II Getting... Started 6 2.1 Installation... 7 2.2 8 Connect...
Spectrum Analyzers. R9211Series. R9211A/9211B/9211C/9211E FFT Analyzer Series. Choice of 4 Types To Fit the Application
Choice of 4 Types To Fit the Application 2-Channel, 16-Bit Resolution, Wide Dynamic Range of 90 db (Typical Value) Maximum Input Sensitivity of -140 dbv (2 khz Range, Typical Value) 10 mhz to 100 khz Frequency
JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410
The INTEG is an Ethernet I/O (digital, analog) device that monitors and controls a small set of process signals. functions as both basic I/O for integration with another application or system AND as a