ABSTRACT INTRODUCTION



Similar documents
Combustible Gas Safety Monitoring: Infrared vs. Catalytic Gas Detectors

How to Select a Flame Detector

Application Requirement

TABLE OF CONTENT

White Paper. Detecting Hydrogen Sulfide Gas and Understanding its Danger in the Field. Introduction

P R O D U C T S P E C I F I C A T I O N MSA Ultima X Series Sensor/Transmitter Specification

Engineering Specifications XNX Universal Transmitter

Sieger Searchpoint Optima Plus

Balancing chemical reaction equations (stoichiometry)

Online Infrared Flue Gas Analyzer Gasboard 3000

Ultima X Series Gas Monitors

Continuous Monitoring of Flue and Combustible or Hazardous Gases and Vapors

THE DETECTION OF GREENHOUSE GASES

The photoionization detector (PID) utilizes ultraviolet

RGC-IR Remote Gas Calibrator for IR400

White Paper. Best Practices for Gas Monitoring in the Commercial Kitchen

EuroFID Total Hydrocarbon Analyzer. Precise Determination of Total Hydrocarbons in Air for Corrosive as well as Condensing Gases

Hydrogen Detection in Oil Refineries

MERIDIAN UNIVERSAL GAS DETECTOR TECHNICAL DATA PACKAGE

Gas and flame detection Stack gas and dust analysis

Automotive Air Quality Sensors: industrial innovations to protect people s health

Fire & Gas Detection; Reducing Risks in Rail Loading/Unloading Facilities. By Todd Spicer Technical Specialist Spartan Controls Fire & Security

PortaSens ll G AS DETECTOR

Ultrasonic Gas Leak Detection

How Sensors Work. How Oxygen, Electrochemical Toxic, and Metal Oxide Semiconductor Sensors Work *

Improving Steam Methane Reformer Performance with the ZoloSCAN-SMR

Hydrogen Detection in Oil Refineries

EzFlex Combustible Gas Leak Detector Model EZ40

EXPLORER 4 MULTIPOINT

MSA Fixed Gas & Flame Detection for the Water & Wastewater Industries

sierra monitor corporation Fire and Gas Detection Systems

FLARE MONITORS FLARE MONITOR (FM) PILOT MONITOR (PM) FLAME INTENSITY (FI)

Title: Standard Operating Procedure for Thermo-Miran SapphIRe portable gas analyzer

DrägerSensor EC Electrochemical Sensors Sensor for Fixed Gas Detectors

The Ambient Air Monitoring System

Buckeye Detection Systems Fixed Detection Systems Application Survey

Certain specific properties of compressed gases make them highly useful in various research activities.

Sentry-MS. Cost Effective Perimeter & LDAR Monitoring. ...Precise, Species Specific. Open Path Multi-gas UVDOAS Analyzer. Ammonia.

ALTAIR 5X Multigas Detector Bid Specification

Natural Gas Emergencies

Gas sensors for greenhouse measurements

PolyGard Carbon Monoxide CO Transmitter ADTX3 1110

MSA Fixed Gas & Flame Detection for the Oil, Gas & Petrochemical Industries

T U R B I N E G A S M E T E R

How To Use A Ds340 (Dsp)

Portable Gas Analyzer with Wireless Transmission of Gas Concentrations and GPS Coordinates

Application Note AN1

Environmental Equipment, Inc. IMR 5000 Continuous Flue Gas Monitoring System IMR 5000

Laser Diode Gas Sensors

North American Stainless

SCBA Frequently Asked Questions

Honeywell Gas Detection Hendrik Heeze

SINGLE-CHANNEL GAS-DETECTOR GAS ALARM DG510/1P

Compressed Gas Cylinder Safety

Gas Detection for Refining. HA University

FIRE ALARM SYSTEM TECHNICAL SPECIFICATIONS Page 1 of 10

The Control of ph and Oxidation Reduction Potential (ORP) in Cooling Tower Applications By Charles T. Johnson, Walchem Corporation

Nitrogen Blanketing for Methanol Storage and Transportation

E - THEORY/OPERATION

DGA - Method in the Past and for the Future

GAS AND FLAME DETECTION

READ FIRST. Confined Space Entry Procedure. San José State University Environmental Health and Safety. Confined Space Entry Procedure

SIX REASONS TO DRY BIOGAS To A LOW DEWPOINT BEFORE COMBUSTION IN A CHP ENGINE STEVEN SCOTT MARKET DEVELOPMENT MANAGER ALTERNATIVE ENERGIES

Fire Alarm System Accessories

Flame detection across the spectrum. Range Brochure

UCLA - Compressed Gas Cylinder Storage and Handling

Q U A D S C A N I I GENERAL User Interface Enclosure Display QUADSCAN II Temperature Range RECEIVER DISPLAY Sensor Weight Optional Relay Enclosure

CHAPTER 7 THE DEHYDRATION AND SWEETENING OF NATURAL GAS

600-GD & 600-GDL 600 SERIES GAS DETECTOR

Chromatograph Maintenance and Troubleshooting Class # 5050

Natural Gas Information Contents

Fiscal Measurement Natural Gas

Thermal Mass Flow Meters

CONFINED SPACE ENTRY WORK STANDARD

Draeger-Tubes and accuro Pump

Chlorine Gas Detection System Operation & Maintenance

CHEMICAL SENSORS 1. DEFINITION

Table of Contents. TransformerIQ FAQs 1

Interface Level And Point Level Analyzers & Sensors

Low Temperature Catalytic Heaters

Optical or Acoustic Process measurement of liquids Turbidity Colour Oil in Water Water in Oil Oil on Water Process UV- Photometry

F ox W hi t e Paper. Reduce Energy Costs and Enhance Emissions Monitoring Systems

Monitoring Air Emissions on Ships. Restricted Siemens AG 2014 All rights reserved.

G4 ICARUS HF. Innovation with Integrity. Simultaneous Determination of Carbon and Sulfur in Solids. Combustion Method

Explosion Protected White Paper Series #1: Imaging Challenges in Explosive Environments

Air Pollution and its Control Measures

BEP FD-2 CONTOUR MATRIX FUME DETECTOR

Ammonia Detection System Codes and Design Specifications

Evaluation of portable flue gas analysers for monitoring carbon dioxide in ambient workplace air HSL/2006/42. Project Leader: Peter Walsh.

Advanced Solutions for Gas Monitoring

Electronic Flow Switches

How To Choose A Total Organic Carbon Analyzer

Technical Specification. Generating Set with Waukesha engine burning natural gas

Continuous flow direct water heating for potable hot water

North American Stainless

Transcription:

Infrared Technology for Fail-To-Safe Hydrocarbon Gas Detection Authors: Dr. Shankar Baliga is Manager of Research & Development at General Monitors. He has a Ph.D. in Physics from Ohio State University and has developed many optical and electrooptical sensing technologies and products. He is a Senior Member of ISA and a voting member on the ISA 12.13 committee for combustible gas detection instruments. He was on the subcommittee that published ANSI/ISA-12.13.04-2007, Performance Requirements for Open Path Combustible Gas Detectors. He can be reached at shankarb@generalmonitors.com. Mr. Shafiq Khan is Director of Corporate Quality at General Monitors. He has a M.S. in Electrical Engineering from Michigan Technological University with over twenty years of experience in gas and fire detection technology development. He can be reached at shafiqk@generalmonitors.com ABSTRACT Continuing advances in infrared technology have resulted in fail-to-safe hydrocarbon gas point detectors that continuously monitor combustible gases and vapors within the lower explosive limit (LEL) and provide alarm indication. Other features of these detectors include operation in oxygen deficient or enriched areas, lack of routine calibration, immunity to poisons, and RS-485 communications link along with 4-20 ma output. Another application of infrared technology is open path detection, which complements point detection. With an open path system there is no definite fixed path length for measuring gas leaks so the measurement is expressed in terms of concentration times path length. The open path system incorporates many of the same advantages of the optical point detector and includes a dual range, ppm.m for small hydrocarbon leaks and LEL.m for more catastrophic leaks. INTRODUCTION Catalytic-type combustible sensors have commonly been used to detect potentially flammable levels of hydrocarbon gas leaks and buildups but suffer from several drawbacks such as sensor poisoning and contamination by harsh environments, and the need for oxygen to maintain sensor accuracy. In the past few years, continuing advances in infrared technology have provided a more reliable yet reasonably priced alternative in infrared absorption based combustible gas sensors. The increased reliability also results in cost savings via reduced maintenance in refineries, petrochemical, and gas producing plants. As described in this article, infrared absorption is an active technology to be distinguished from passive technologies of which the electrocatalytic bead is the most common.

LIMITATIONS OF ELECTROCATALYTIC TECHNOLOGY The heart of an electrocatalytic or catalytic bead sensor is a platinum coil that is coated with a catalyst. This element is heated, and in the presence of a combustible gas a reaction takes place on the surface of this element with oxygen in the air to heat up the catalytic element. This causes a resistance change in the embedded coil that is measured and monitored. The sensor also uses a reference bead that is passivated with a glass coating; the reference compensates for changes in ambient temperature, humidity, and pressure without responding to combustible gases that do not penetrate the coating. The catalyst employed in these sensors is critical to the accuracy and life of the sensor, and impacts the variety of combustible gases the sensor can detect. Fig. 1 Catalytic Bead Sensor Although catalytic bead sensors have been in use for decades, the technology has some drawbacks. One critical limitation is the inability to operate in an environment deficient in oxygen since the bead requires efficient oxidation of hydrocarbon gas; oxygen levels impact oxidation efficiency; and hence, the sensor s accuracy. Another drawback is the possibility of sensor poisoning by chemical compounds such as silicones and sulfur compounds leading to a decline in catalytic activity. Contamination of the sensor is also possible, for example, by trapping of dust in the flame arrestor or exposure to heavy oils and greases. Contamination can show up during normal maintenance of the system as an increase in the response time to calibration, recovery time after exposure, and loss of sensitivity. Since these conditions can occur without warning to the operator, electrocatalytic hydrocarbon sensors are not fail-to-safe; fail-to-safe in this instance implies the sensor s ability to communicate its dysfunctional status to the operator for the various failure modes. For example, the operator may not know the poisoned status of the catalytic bead until calibration gas is required. This results in an increase in calibration intervals in areas where poisoning agents are suspected to exist. Although the infrared technology described in this paper is gradually becoming the preferred method of gas detection, catalytic sensors are still the sensor of choice when it comes to operating the sensor head above 75 C. This is because of these devices can withstand and operate at much higher temperatures (up to 200 C) than the commonly used instruments in infrared technology. Also, when calibrating a unit in the field or for calibrating a unit to a different gas in the field, the procedure may be simpler with the catalytic bead owing to sensor linearity. Hydrocarbon sensors based on infrared (IR) absorption principles do not suffer from the drawbacks of catalytic bead sensors described above. This leads to increased reliability and a hydrocarbon monitoring

system that requires little maintenance for years. IR instruments offer fail-to-safe operation since the optical technology is an active one, able to communicate the sensor s status and faults to the operator. The IR hydrocarbon gas detector can be classified into two types known as point detectors and open path detectors. IR GAS SENSING TECHNOLOGY The IR method of measuring gas concentration is based on the absorption of IR radiation at certain wavelengths as the radiation passes through a volume of the gas. IR hydrocarbon gas detectors can be classified into two types known as point detectors and open path detectors. For point detectors, the absorption path length is fixed, and is determined by the instrument design to be a few inches. For the open path IR detectors, the absorption path length can be as long as 130 meters as opposed to the few inches of the point detector. Instruments based on IR technology use two wavelengths, one at the gas absorbing wavelength and the other at a wavelength not absorbed by the gas; neither wavelength is absorbed by the other atmospheric constituents such as water vapor, nitrogen, oxygen, or carbon dioxide. Fig. 2 Open Path Infrared System IR gas sensing technology provides for fail-to-safe operation in contrast to electrocatalytic sensors since optical sensing is an active technology, which continuously monitors for sensor faults and communicates them to the user. This is achieved chiefly through the use of the second or reference wavelength. IR detectors are also immune to poisoning, resistant to corrosion, can operate in a deficit or surplus of oxygen, and do not suffer from reduction in sensor life on repeated exposure to gas. With the sophisticated optical and electronic designs currently being used, the detectors are factory calibrated and virtually maintenance free. This is particularly desirable when sensors must be located in inaccessible areas and cannot be easily calibrated on a periodic basis. Point IR Detectors Point combustible gas detectors are used to monitor the presence of flammable levels of hydrocarbon gas or vapor in industrial environments such as refineries and chemical plants. If the concentration of the hydrocarbon gas or vapor exceeds its Lower Explosive Level (LEL), the gas can be ignited and lead to an explosion. Point combustible gas detectors are therefore located at several dozen sites to monitor for gas leaks. In the point IR detector, the concentration of hydrocarbon gas is measured via the infrared absorption of an optical beam known as the active beam.

Fig.3 Model IR2100 Point Detector optical scheme A second optical beam known as the reference follows the same optical path as the active but contains radiation at a wavelength not absorbed by the gas. This second beam provides for the fail-to-safe operation of the point IR detector; a feature that is not available with the electrocatalytic technology. In the Model IR2100 manufactured by General Monitors, the two wavelengths are generated by two infrared sources which have the active and reference filters attached to them, are pulsed alternately and guided by the optics onto a common optical path. A detector receives the two optical pulses after they have traversed the optical absorption path. All the components of the instrument are mounted inside an explosion-proof housing with infrared transparent optical windows. Maintenance on IR detectors is typically limited to periodic cleaning of the external optical windows and reflectors to ensure dependable performance. The current availability of reliable, low cost electronics and solid state IR detectors have reduced costs and made the technology feasible for many commercial applications. Typical Gases Monitored Methane Ethane Propane Butane Pentane Hexane Benzene Other Gases Monitored Isopropylamine Propylene Ethylene Oxide Propylene Oxide Ethanol Methanol Fig. 4 Model IR2100 - Infrared Point Gas Detector and Gases Monitored The signals from the IR detector are converted into digital format and processed by a microprocessor with the help of a gas concentration lookup table and a correction factor for ambient temperature variations. The instrument outputs a 4-20 ma analog signal as well as a RS485 serial output. Use of the RS485 using the MODBUS RTU protocol provides two-way addressable communication for status, alarm, fault, and other information for operation, trouble shooting, or programming the unit. MODBUS also permits linking of up to 128 point detectors in series and up to 247 point detectors using repeaters. A typical system configuration linking 20 gas detectors and 20 flame detectors is shown in Fig. 5.

Fig. 5 Multi-drop Addressable System The gas tables of up to eight gases can be stored in the memory of the microprocessor; the gases include the hydrocarbons of the series methane, ethane, and propane as well as aromatics such as benzene. These and other gases (see Fig. 4 for a list which is not exhaustive) can be detected in the 0 to 100% LEL range, though the unit is also capable of measuring 0 to 100% V/V if desired. The limiting factor of this IR technology is that the gas to be measured has to be infrared active as with hydrocarbons. A point IR detector that has been modified to be sensitive to the appropriate absorbing wavelength can also monitor gases other than hydrocarbons. An example of such detector is the IR7000 point IR detector, capable of measuring 0 to 5000 ppm of carbon dioxide. This instrument is derived from the standard IR2100 by using optics and filters suited to the 4.3-μm absorption band of carbon dioxide. The IR2100 and IR7000 infrared point gas detectors are available with demonstration and setup software (Fig. 6), which permits the actual signal levels and gas readings to be observed on a monitor screen in real time, along with the temperature and 4 to 20 ma output. Fault and alarm conditions may also be observed. Normal Condition Alarm Condition Open Path IR Detectors Fig. 6 Point IR Software Diagnostic Screens In open path IR gas detectors, the concepts of the point IR detector are expanded to a gas sampling path which can be as long as 130 meters as opposed to a few inches internal to the instrument. These systems can either use a retro-reflector or, as is the case with the Model IR5000 from General Monitors, use separate IR transmitters and receivers housed in explosion-proof housings. In the IR5000, the active and reference wavelengths for hydrocarbon detection are alternately selected via a rotating filter wheel, while the source is a broadband IR emitter. Open path IR detectors offer many of the same advantages as the point IR technology such as immunity to poisons, high sensitivity leak detection, low maintenance, fail-to-safe detection, and easy installation.

Fig. 7 Model IR5000 Open Path Infrared Gas Detection System Unlike point gas detectors, open path IR detectors do not pinpoint the location of a leak since the leak can occur anywhere along the optical path. The gas concentration output for open path detectors is therefore expressed in ppm.meters or LEL.meters since only the product of the average gas concentration and gas cloud length can be calculated. This means that a small dense cloud of hydrocarbon gas could give the same output as a large dispersed cloud if the integral of the gas concentration over the path length were the same. A unique feature of the Model IR5000 is a dual range, ppm.m for small hydrocarbon leaks and LEL.m for more catastrophic leaks, with the ability to switch between ranges as required. Open path systems are particularly useful in those situations where a gas release has been dispersed by wind or natural diffusion. The gas can still be detected, even though its point concentration may have fallen below normal alarm settings for point detectors. If a gas leak creates a cloud, it generally has the following characteristics: The highest gas concentration of a cloud is at the source and it decreases in concentration towards the edges. The shape of the gas cloud is elongated or has an irregular pattern, depending upon air currents. In outdoor environments gas clouds dissipate more quickly and can have very low gas concentrations (see Figure 8). Fig. 8 IR5000 and Evolution of a Leaking Gas Cloud

Open path systems have the advantage of being able to cover large open areas, a line of several potential leak sources such as a row of valves or pumps, and also for perimeter monitoring of leaks. A mirror can also be used to deflect the optical beam around a corner to the receiver. Whereas hydrocarbon detection systems use relatively inexpensive components and are used to monitor larger leaks, more expensive diode laser based systems are currently available that can monitor toxic gases such as hydrogen fluoride and hydrogen sulfide at low ppm.meter levels. Open path gas detection is not an all-encompassing answer to gas detection, but offers another solution to gas detection challenges and should be used in combination with point gas detection due to the limitations in targeting specific locations of gas leaks. Fig. 9 shows a typical installation that uses both IR2100 point detectors as well as IR5000 open path detectors to provide adequate gas leak detection coverage. Open path detectors are used outdoors to monitor loading and unloading from rail cars and to monitor storage tanks. Point detectors are used indoors and at potential leak sites outdoors like pumps and tank farms. Fig. 9 Typical Installation for IR2100/IR5000 Point and Open Path Gas Detectors For further information, please contact the authors at: General Monitors 26776 Simpatica Circle Lake Forest, CA 92630 Phone: 949-581-4464 Fax: 949-581-1151 Email: info@generalmonitors.com