Dubai Municipality Standard DMS 1: Part 5: 2004



Similar documents
EXPANDED POLYSTYRENE (EPS) INSULATION BOARD SPECIFICATIONS

Understanding BS EN 771-3: Aggregate concrete masonry units

CERTIFICATE NAME OF PRODUCT MANUFACTURER PRODUCT DESCRIPTION CERTIFICATION PROCEDURE. No VTT C Date of issue , Updated July 1, 2011

Fire 2This Technical Bulletin has been commissioned by the UK SIP Association in

Annex of the certificate (Page 1/6) Accreditation Scope

European Technical Approval ETA 13/0526

THERMAL INSULATION MATERIALS TEST METHOD SELECTION LIST

Treatment of a surface or structure to resist the passage of water in the absence of hydrostatic pressure. presence of hydrostatic pressure.

NCMA TEK CONCRETE MASONRY FOUNDATION WALL DETAILS. TEK 5-3A Details (2003)

Mandate M/116 MASONRY AND RELATED PRODUCTS

Loss Prevention Standard

Guide Specification STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM

SECTION PRECAST CONCRETE STRUCTURES

TECHNICAL SPECIFICATION SERIES 8000 PRECAST CONCRETE

INTERNATIONAL ASSOCIATION OF CLASSIFICATION SOCIETIES. Interpretations of the FTP

Construction Materials Testing. Classes of Test

Composite Panel Firewall Systems

Section 5.0. Basements. Wall insulated externally. Wall insulated internally. Ba02. Product: Polyfoam ECO Floorboard Ba01.

Detailing of Reinforcment in Concrete Structures

Guide for SOLID CONCRETE BLOCK SEALS

Introduction. Facade Fire Test on PUR External Thermal Insulation Composite System (ETICS)

Cavity Drain R20 is manufactured from1.0mm thick black high density polyethylene with studs approximately 20mm high.

cement Masonry Cement Engineered for quality and reliability, Lafarge cements for masonry deliver consistent performance. page 2 Lafarge Cement

Mold Preventing I nterior System

European technical approval

NRDCA 400 GUIDELINE FOR FIELD APPLICATION of LIGHTWEIGHT INSULATING CONCRETE REROOFING/RECOVER SYSTEMS

SPECIFICATION Section Insulated Precast Concrete Wall Panels

Built to Last. Built for Beauty. Good. Solid. Logix. TM

GRADATION OF AGGREGATE FOR CONCRETE BLOCK

How To Test For Premer Retardant

CHESTERFLEX ROOF WATERPROOFING MEMBRANES

SECTION 55 PIPE FOR STORM DRAINS AND CULVERTS (FAA D-701)

SPECIAL COMPOUND FOR RHEOPLASTIC AND ANTI-CORROSION SUPERCONCRETE WITH VERY HIGH DURABILITY

Design and Construction of Cantilevered Reinforced Concrete Structures

GigaCrete Specification PlasterMax

FERMACELL Powerpanel H 2 O for Wet & Moisture affected areas

18 June 2001 GUIDELINES ON FIRE TEST PROCEDURES FOR ACCEPTANCE OF FIRE-RETARDANT MATERIALS FOR THE CONSTRUCTION OF LIFEBOATS

Tex-421-A, Splitting Tensile Strength of Cylindrical Concrete Specimens

ROXUL Board Insulation Section Master Guide Specification (CAVITYROCK ) Page 1 April 2016

NAPCA BULLETIN APPLICATION PROCEDURES FOR CONCRETE WEIGHT COATING APPLIED BY THE COMPRESSION METHOD TO STEEL PIPE

Tremco Fire Protection Systems Group Technical Bulletin

) and air spaces (R a

R-VALUES AND U-FACTORS OF SINGLE WYTHE CONCRETE MASONRY WALLS. TEK 6-2B Energy & IAQ (2009) Related TEK: 6-1B, 6-11, 6-12C INTRODUCTION

Asphalt Shingle Application Requirements

SECTION STORM DRAINAGE SYSTEM

CORROSION ENGINEERING RESIN-BASED POLYMER CONCRETES AND GROUTS

LAYING BLOCK AND BRICK

Construction. 3-part thixotropic epoxy patching mortar. Product Description. Tests

ETAG 004 EXTERNAL THERMAL INSULATION COMPOSITE SYSTEMS WITH RENDERING

Fiberglas, Exterior Wall Thermal Insulation

R-VALUES AND U-FACTORS OF SINGLE WYTHE CONCRETE MASONRY WALLS. TEK 6-2C Energy & IAQ (2013) Related TEK: 2-5B, 6-1C, 6-4B, 6-11A, 6-12C, 6-12D, 6-12E

EXPERT OPINION on the applicability of the construction technology "GRÈMOUND non-tectonic system on grounds of the documentation submitted

COMMERCIAL ITEM DESCRIPTION PACKAGING MATERIAL, SHEET

Check-list for auditors. Audit visit at candidate registered laboratories

SPECIFICATIONS. INTERLOCKING CONCRETE POROUS PAVING UNITS or Permeable Interlocking Concrete Pavers (PICP)

7. Installation. installation CAST-IN WINDOW SYSTEM 7.1. INSTALLATION OF WINDOW MAIN FRAME

European Organisation for Technical Approvals

Fire Resistance of Brick Masonry

1/9/2013. Terminology Calculating Heat Transfer Code Requirements Design Examples and Sustainability

HIGH PERFORMANCE PRE-APPLIED SYSTEM FOR BLIND SIDE & BELOW GRADE WATERPROOFING APPLICATIONS

COMPACTING BITUMINOUS SPECIMENS USING THE SUPERPAVE GYRATORY COMPACTOR (SGC)

Knauf Aquapanel Interior. Tile Backing. Cement board for wet areas. Will not deteriorate in water. Easy to score and snap

SECTION PRE-ENGINEERED BUILDING BLANKET INSULATION

Insulated Roof & Wall Panels. Product Data Sheet. Trapezoidal Insulated Roof Panels KS1000 RW

CCU Engineering Specifications. Section PRECAST CONCRETE PRODUCTS

TABLE OF CONTENT

European Technical Approval ETA 13/0384

Simplifying design and construction. Alan Tovey, Director The Basement Information Centre

COMMONLY USED RESIDENTIAL BUILDING CODES

1997 Uniform Administrative Code Amendment for Earthen Material and Straw Bale Structures Tucson/Pima County, Arizona

GYPSUM BOARD, GYPSUM PANEL PRODUCTS AND PLASTER

Example Specification for Concrete using Current Building Code Requirements

Effect of basalt aggregates and plasticizer on the compressive strength of concrete

FederalDemocratic RepublicofEthiopia

WATERPROOFING FOR CONCRETE STRUCTURES

FLAMMABILITY REQUIREMENTS FOR AIRCRAFT SEAT CUSHIONS

TARIFF CODE and updates standard

English version. Raised access floors

necessary for years of satisfactory service. SmartBlock insulating form concrete walls share the

STANDARD SPECIFICATION. for. Plumbing, Heating, Hot Water, Cold Water & Electrical work. Sussex Lodge London W2 & 16 Stanhope Terrace London W2

Steel-framed Walls. Insulation

Technical Notes 3B - Brick Masonry Section Properties May 1993

Precast Concrete Insulated Sandwich Wall Panels

B. ASTM C 533 Calcium Silicate Block and Pipe Thermal Insulation. C. ASTM C 547 Mineral Fiber Preformed Insulation

4 Installation Requirements

Excerpts from the Canadian National Building Code (NBC)

Light-Weight Panels. High quality panels.

ENGINEERING SPECIFICATION PULTRUDED DYNARAIL FIBERGLASS LADDER & LADDER CAGES

DESIGN OF SLABS. 3) Based on support or boundary condition: Simply supported, Cantilever slab,

FLOORS REINFORCEMENT Shear Stud Connector for steel- concrete composite structures cold applied by pins

Roxul Board Insulation Section Master Guide Specification (CAVITYROCK DD) Page 1 October 2013

PRESENTATION ON REPAIR AND REHABILITATION OF BUILDINGS DAMAGED IN EARTHQUAKE. By H P Gupta & D K Gupta

Chapter 3 Pre-Installation, Foundations and Piers

Monocouche Best Practice Guide. New-Build Housing Managing movement to avoid cracking

Laying the First Course. 1. Excavate the site and construct the footing.

CONTRACT SPECIFICATIONS - SEISMIC ISOLATION BEARINGS

1.5 Concrete (Part I)

Master Panel 1000 W Wall

SERIES NG 1800 STRUCTURAL STEELWORK

Transcription:

Specification for precast concrete blocks Part 5: Normal-weight concrete-polystyrene sandwich masonry blocks Issue Date Revision Revision Description Prepared by Approved by Authorized by 19/12/2004 Issue for use This document is the property of Dubai Municipality and its issue is controlled. No part of this document should be reproduced or copied without the prior written permission of Dubai Central Laboratory Department.

Table of Contents Page Foreword ii 1 Scope 1 2 References 1 3 Definitions 1 4 Materials 1 5 Polystyrene core properties 2 6 Sandwich block properties 3 7 Sampling for tests 4 8 Intended use 4 Annex A: Site application of Sandwich-block 6 Table 1 Dimensions of Sandwich-blocks 3 Figures 1 Example of polystyrene core 2 2 Example of a Sandwich-block 3 i Issue Date 19/12/2004

Foreword With a view to having a comprehensive set of unified Dubai Municipality Standards which would be consistent and appropriate to local conditions and yet be at par with International Standards, the Dubai Central Laboratory Department is formulating standards taking guidance as much as possible from International and Regional Norms. This Standard sets the minimum requirements for a new type of precast concrete masonry block that is introduced in the local market to be used as thermal insulating block. Besides the basic requirements of the block, this Standard addresses the connectivity and stability requirements of a wall constructed using this type of block. This Standard also includes an annex for the site applications of the thermal insulatingblocks. Request Number: S-059-04-RS Standards Committee: Dr. S. M. K. Chetty RSMO / DCL (Head of Committee) Aslam Riaz EMS / DCL (Member) Sameer Darwish EMS / DCL (Member) Khalil Al Mubayed I&CU / DCL (Member) Khader Akkawi RSMO / DCL (Coordinator) Amendments issued since publication Amd No. Date Text affected ii Issue Date 19/12/2004

1 Scope This standard specifies materials and minimum performance levels for precast concretepolystyrene masonry Sandwich-blocks. Also addresses the connectivity and stability requirements of a wall constructed using this type of block 2 References This standard incorporates provisions from other references. These references are cited undated at the appropriate points in the text, but latest edition of these references applies (including amendments). The titles of these references are listed on the last page. 3 Definitions 3.1 Normal weight concrete Concrete having an oven-dry density greater than 2000 kg/m 3 but not exceeding 2600 kg/m 3. 3.2 Expanded polystyrene Rigid cellular plastic material, manufactured by molding beads of expandable polystyrene or one of its copolymers, with an air filled closed cellular structure. 3.3 Extruded polystyrene Rigid cellular plastics insulation material expanded and extruded with or without a skin, from polystyrene or one of its copolymers and which has a closed cell structure 3.4 Sandwich-block A precast concrete block consisting of two outer leaves of normal weight concrete sandwiching a polystyrene core. 3.5 Lot The term Lot refers to any number of Sandwich- blocks of a specific configuration or dimension manufactured by the producer using the same materials, concrete mix, manufacturing process, and curing method. 4 Materials 4.1 Binders Precast concrete portion of Sandwich-blocks shall be made using Portland cement of type CEM 1 to BS EN 197 Part 1 4.2 Aggregates The normal-weight aggregates used shall conform to the requirements of BS EN 12620 and the recommendations of PD 6682 Part 1, except for the grading requirement. 4.3 Admixtures The admixtures used shall be free from chlorides and conform to BS EN 934: Part 2. 4.4 Water The water used shall be clean and free from any deleterious and organic matter, and conform to BS EN 1008. 1 Issue Date 19/12/2004

4.5 Thermal insulation core Thermal insulation core of the sandwich block shall be made of either expanded polystyrene or extruded polystyrene that complies with the requirements of clause (5) of this Specification and shall be certified by Dubai Municipality.. 5 Polystyrene core properties 5.1 Size and shape Polystyrene core of the Sandwich-block shall have the same length and height of the overall concrete dimensions. Polystyrene core thickness, when measured at any point, shall not be less than 60 mm. Polystyrene core shall have a dovetailing shape as shown in Fig. 1. Other shapes can also be used. Polystyrene core shall be either molded or extruded to shape without cutting. Fig. 1: Example of a polystyrene core 5.2 Apparent density When tested in accordance with BS EN 1602, for a sample of five specimens, the average apparent density shall be not less than 25 kg/m 3. 5.3 Thermal conductivity Thermal conductivity of the polystyrene core shall be declared by the polystyrene manufacturer according to BS EN ISO 10456 at 35ºC and 60% relative humidity (RH). When tested in accordance with BS EN 12667 or ASTM C 518, at 35ºC & 60% RH, polystyrene core thermal conductivity shall not exceed the declared value. 5.4 Reaction to fire Polystyrene shall be of the flame-retardant type. When tested in accordance with BS EN 11925-2, the flame spread shall not exceed 150 mm within 60 s. Alternatively, the Oxygen index shall no be less than 24% by volume when tested in accordance with ASTM D 2863. 2 Issue Date 19/12/2004

6 Sandwich block properties 6.1 Sizes 6.1.1 Dimensions Sandwich-block overall dimensions shall conform to the requirements of Table 1. If air cavities exist in any of the two concrete leaves of the Sandwich-block, the shell thickness shall not be less than 20mm. A sample block is shown in Fig. 2. Table 1 - Dimensions of Sandwich-blocks Sandwich-block sizes Length (mm) Height (mm) Thickness (mm) 400 200 200 400 200 250 Note: Other dimensions can be declared by the manufacturers. Fig. 2: Example of a Sandwich-block 6.1.2 Tolerances When measured in the manner described in BS 6073: Part 1 appendix A, the length, height or thickness of each block from the sample shall not differ by more than ± 3 mm from the stated dimensions. 6.2 Manufacturing Sandwich-blocks are manufactured using normal weight concrete cast integrally with the dovetailed polystyrene core placed in the mould and wet concrete poured around it. The 3 Issue Date 19/12/2004

concrete is then compacted and cured. These processes are to be carried out without damage to the polystyrene core. 6.3 Chloride and sulfate content When tested in accordance with BS 1881 : Part 124, the acid soluble chloride (Cl) and sulfate (SO 3 ) content of Sandwich-blocks concrete shall not exceed 0.06% and 0.4% by dry mass of concrete respectively. 6.4 Compressive strength When tested in accordance with appendix B of BS 6073: Part 2, for a sample of ten Sandwich-blocks, the average compressive strength and that of an individual specimen, based on the gross area, shall be not less than the following: Average compressive strength: 7.5 N/mm 2 Individual compressive strength: 6.0 N/mm 2 Sandwich-blocks shall maintain their integrity during the compressive strength test i.e. failure pattern during compressive strength test shall not show evidence of separation between the polystyrene core and the outer concrete leaves. Any evidence of separation noticed before or during the test shall be a cause for rejection of the lot represented by the sample. 6.5 Thermal properties Thermal conductivity of the Sandwich-blocks shall be declared by the block manufacturer according to BS EN ISO 10456 at 35ºC and 60% relative humidity (RH). When tested in accordance with BS EN 12664 or BS EN 12667 or BS EN 1934 or BS EN ISO 8990 or ASTM C 1363, at 35ºC and 60% RH, Sandwich-block thermal conductivity shall not exceed the declared value. As an alternative, thermal conductivity of the Sandwich-blocks shall be calculated according to BS EN ISO 6946 taking into consideration the block configuration, concrete and polystyrene thermal conductivities declared by their manufacturers at 35ºC & 60% RH. 7 Sampling for tests 7.1 Number of Specimens The number of specimens required for each specified test shall be : - Sandwich-block dimensions and Compressive strength 10 blocks - Sandwich-block Concrete Chloride and Sulfate content 1 block - Sandwich-block thermal conductivity or Concrete thermal conductivity As required by the testing laboratory - Polystyrene core dimensions and apparent density 5 core specimens - Polystyrene core thermal conductivity 1 core specimen 4 Issue Date 19/12/2004

7.2 Selection of test specimens A representative sample of Sandwich-blocks required for test purposes shall be selected at random from every designated lot of 20,000 Sandwich-blocks or fraction thereof. Each specimen shall be marked so that it may be identified at any time. 8 Intended use Sandwich-blocks are intended to be used as thermal insulating blocks for the construction of infill, non-load bearing, masonry walls in buildings. Sandwich-blocks shall be used in superstructures only and shall not be used in substructures. 5 Issue Date 19/12/2004

Annex A: Site application of Sandwich-blocks A- Site storage Ultra-Violet light adversely affects the polystyrene properties. Therefore, polystyrene cores should be stored or kept in closed places unexposed to solar radiation. Also, Sandwichblocks need to be protected from exposure to solar radiation during their storage and handling until the time of erection where the polystyrene is then fully protected. B- Handling Sandwich-blocks need to be handled with care to avoid damage such as chipping of edges and corners, splitting between the polystyrene core and the outer concrete layers, etc. C- Thermal bridging Mortar joints in masonry walls built with Sandwich-blocks will act as a thermal bridge due to the high thermal conductivity of the mortar compared to the polystyrene core. To avoid this thermal bridge, 45 mm wide Polystyrene strips, having a thickness equal to the mortar joints thickness, may be included in the horizontal and vertical mortar joints to provide continuity for the Polystyrene thermal insulation layer. As an alternative, light weight aggregate concrete mortar with low thermal conductivity can be used as full bed mortar joints without any polystyrene strips. Other alternatives can also be used. D- Installation Care should be taken to align the blocks both horizontally and vertically in a way that the polystyrene cores of adjacent blocks are not staggered. This is of great importance so as to avoid forming thermal bridges inside the walls. E- Reinforcement E/1- Polystyrene may loose its adhesion with the concrete with time leaving the two concrete leaves of the Sandwich-block apart without any connection. To ensure the connectivity of the two concrete parts together, the methods discussed in clause (E/2) can be applied. E/2- Methods of connection: - Alkali resistant fiber mesh reinforcement 150 mm wide, or galvanized metal mesh or ladder type wire mesh reinforcement 150 mm wide, embedded in the mortar joints at every third course. - 150 mm long ties complying with the requirements of BS EN 845: Part 1 shall be placed in mortar joints at a rate not less than 4.9 ties per one square meter of wall area. - Other methods for ensuring connectivity may be used. 6 Issue Date 19/12/2004

E/3- Column-masonry junctions shall be connected by galvanized wall ties, 2.5 mm x20 mm x 150 mm, complying with the requirements of BS EN 845: Part 1, at every third course. E/4- If the wall height is more than 3.5 m, galvanized beam-masonry wall ties of 2.5 mm x 20 mm x 75 mm, complying with the requirements of BS EN 845: Part 1, shall be fixed at 1.2 m c/c approximately. E/5- Concrete stiffeners should be provided around windows and doors openings to allow for stiffening the wall free ends. F- Condensation To avoid the condensation problem that is expected to happen in walls built with Sandwichblocks, special coatings that have very low water-vapor permeability characteristic shall be applied on the external surface of the walls. 7 Issue Date 19/12/2004

G- Publications referred to: BS 1881: Part 124 BS 4027 BS 6073: Part 1 BS 6073: Part 2 BS EN 197: Part 1 BS EN 845: Part 1 BS EN 934: Part 2 BS EN 1008 BS EN 1602 BS EN 1934 BS EN 11925: Part 2 BS EN 12620 Method for analysis of hardened concrete Specification for sulfate-resisting Portland cement Specification for precast concrete masonry units Method for specifying precast concrete masonry units Cement Part 1: Composition, specifications and conformity criteria for common cements Specification for ancillary components for masonry Part 1: Ties, tension straps, hangers and brackets Admixtures for concrete, mortar and grout Part 2: Concrete admixtures Definitions, requirements, conformity, marking and labeling Mixing water for concrete Thermal insulation products for building applications determination of apparent density Thermal Performance of Buildings - Determination of Thermal Resistance by Hot Box Method Using Heat Flow Meter - Masonry Reaction to fire tests Ignitability of building products subjected to direct impingement of flame Part 2: Single flame source test Aggregates for concrete BS EN 12664 Thermal performance of building materials and products Determination of thermal resistance by means of guarded hot plate and heat flow meter methods dry and moist products of medium and low thermal resistance BS EN 12667 Thermal performance of building materials and products Determination of thermal resistance by means of guarded hot plate and heat flow meter methods products of high and medium thermal resistance BS EN ISO 6946 BS EN ISO 10456 BS EN ISO 8990 Building components and building elements Thermal resistance and thermal transmittance Calculation method Building materials and products Procedures for determining declared design thermal values Thermal insulation Determination of steady-state thermal transmission properties Calibrated and guarded hot box 8 Issue Date 19/12/2004

ASTM C 518 ASTM C 1363 ASTM D 2863 Standard Test Method for Steady-State Thermal Transmission Properties by Means of the Heat Flow Meter Apparatus Standard Test Method for the Thermal Performance of Building Assemblies by Means of a Hot Box Apparatus Standard Test Method for Measuring the Minimum Oxygen Concentration to Support Candle-Like Combustion of Plastics (Oxygen Index) 9 Issue Date 19/12/2004