Instrument/Method Validation. Lebah Lugalia Lab QA/QC Coordinator UNC Project Lilongwe, Malawi



Similar documents
How to Verify Performance Specifications

USING CLSI GUIDELINES TO PERFORM METHOD EVALUATION STUDIES IN YOUR LABORATORY

Laboratory Director Responsibilities

Validation and Calibration. Definitions and Terminology

OPERATIONAL STANDARD

Method Validation/Verification. CAP/CLIA regulated methods at Texas Department of State Health Services Laboratory

Analytical Test Method Validation Report Template

Content Sheet 7-1: Overview of Quality Control for Quantitative Tests

Installation and Operational Qualification Protocol (Reference: SOP )

Step-by-Step Analytical Methods Validation and Protocol in the Quality System Compliance Industry

Assay Qualification Template for Host Cell Protein ELISA

A Practical Guide to Internal Quality Control (IQC) for Quantitative Tests in Medical Laboratories

Test Reliability Indicates More than Just Consistency

2010 Laboratory Accreditation Program Audioconference. Accreditation Requirements for Waived Vs. Non-waived Tests

American Association for Laboratory Accreditation

Methods verification. Transfer of validated methods into laboratories working routine. Dr. Manuela Schulze 1

Why System Suitability Tests Are Not a Substitute for Analytical Instrument Qualification

Applying Statistics Recommended by Regulatory Documents

Basic Lessons in Laboratory Quality Control

Urinalysis Compliance Tools. POCC Webinar January 19, 2011 Dr. Susan Selgren

Procedure: Quality Assurance Policy Version 5 Quality Assessment Policy Version 3

Validation of measurement procedures

NIST HANDBOOK CHECKLIST CONSTRUCTION MATERIALS TESTING

Assay Development and Method Validation Essentials

Evaluating Laboratory Data. Tom Frick Environmental Assessment Section Bureau of Laboratories

1 Quality Assurance and Quality Control Project Plan

International GMP Requirements for Quality Control Laboratories and Recomendations for Implementation

ASSURING THE QUALITY OF TEST RESULTS

Assay Migration Studies for In Vitro Diagnostic Devices Guidance for Industry and FDA Staff

Calibration Verification

OMCL Network of the Council of Europe QUALITY MANAGEMENT DOCUMENT

To avoid potential inspection

Measurement Systems Correlation MSC for Suppliers

Calibration & Preventative Maintenance. Sally Wolfgang Manager, Quality Operations Merck & Co., Inc.

Working Party on Control of Medicines and Inspections. Final Version of Annex 15 to the EU Guide to Good Manufacturing Practice

Quality Control of the Future: Risk Management and Individual Quality Control Plans (IQCPs)

Control Charts and Trend Analysis for ISO Speakers: New York State Food Laboratory s Quality Assurance Team

Application of Sigma Metrics for the Assessment of Quality Assurance in Clinical Biochemistry Laboratory in India: A Pilot Study

APPENDIX N. Data Validation Using Data Descriptors

QbD Approach to Assay Development and Method Validation

Six Sigma Quality New Metrics vs Old Myths

Building Credibility: Quality Assurance & Quality Control for Volunteer Monitoring Programs

Flow Cytometry. CLIA Compliance Manual*

1 For more information T: / E: DAP@ul.com / W: ul.com/dap

Agilent Cary 60 UV-Vis

CHAPTER 7 QUALITY ASSESSMENT

Best Practices for Maintaining Quality in Molecular Diagnostics Gyorgy Abel, MD, PhD

Design of Experiments for Analytical Method Development and Validation

CAP Point of Care Checklist Frequently Asked Questions Roger D. Klein, MD Sheldon Campbell, MD, PhD Peter J. Howanitz, MD

Process Validation for Medical Devices

A.1 Sensor Calibration Considerations

Development and Validation of In Vitro Diagnostic Tests. YC Lee, Ph.D. CEO

Laboratory and Technician Certification. by Nabil Kamel, M.A.Sc., P.Eng. CCIL Program Manager

Quality Assurance for the Clinical Laboratory

Rashika Maharaj. Strategies for maintaining high standards for Good Clinical Laboratory Practices

Contents. Abstract... i. Committee Membership... iii. Foreword... vii. 1 Scope Introduction Standard Precautions...

Guidance for Industry

SureStep Pro Linearity Test Kit and Analytical Measurement Range Verification (AMR)

Document Review: Centers for Medicare and Medical Service (CMS) What Do I Need to Do to Assess Personnel Competency?

Assessment of Accuracy and Precision

Inspections: Central Laboratory of the Regions

VALIDATION OF ANALYTICAL PROCEDURES: TEXT AND METHODOLOGY Q2(R1)

James O. Westgard, PhD, 1,2 and Sten A. Westgard, MS 2. Abstract

INTEROPERABILITY UNIT

Quality Assurance Procedures for Construction and Materials Sampling and Testing 14

DATA QUALITY OBJECTIVES

Quality Assurance/Quality Control in Acid Deposition Monitoring

TEST METHOD VERIFICATION AND VALIDATION

Process Validation: Practical Aspects of the New FDA Guidance

QUALITY MANUAL GREAT LAKES INSTITUTE FOR ENVIRONMENTAL RESEARCH ANALYTICAL LABORATORIES. October 2008 Revision 08

4 QUALITY ASSURANCE 4.1 INTRODUCTION

No Page 1 of 5. Issue Date 4/21/2014

Mouse Insulin ELISA. For the quantitative determination of insulin in mouse serum and plasma

VERIFYING CALIBRATION OF WEIGHING DEVICES USED FOR LABORATORY TESTING

QUALITY MANAGEMENT IN VETERINARY TESTING LABORATORIES

ORACLE CONSULTING GROUP

The Regulatory Binder/Trial Master File: Essential Records for the Conduct of a Clinical Trial

Qualification Study CHO 360-HCP ELISA (Type A to D)

Data Quality. Tips for getting it, keeping it, proving it! Central Coast Ambient Monitoring Program

Considerations When Validating Your Analyst Software Per GAMP 5

Definition of Minimum Performance Requirements for Analytical Methods of GMO Testing European Network of GMO Laboratories (ENGL)

Document Control for Control Freaks. Kristina Martin, MLS(ASCP) CM,MS

ASVCP Guidelines: Quality Assurance for Point of Care Testing in Veterinary Medicine

Introduction to Cloud Computing What is SaaS? Conventional vs. SaaS Methodologies Validation Requirements Change Management Q&A

ANALYTICAL METHODS INTERNATIONAL QUALITY SYSTEMS

IMPAACT INTERNATIONAL LABORATORY QUALITY ASSURANCE PROGRAM

What Does Having a FDA Cleared Pregnancy Test Mean?

Biochemistry Validation Form

SAGE SCIENCE INC. Pippin Prep IQ/OQ Rev. A Originated: March 5, Sheet 1 of 11. Prepared by: Alex Vira SUMMARY

Guide to Method Validation for Quantitative Analysis in Chemical Testing Laboratories

Installation Qualification/Operational Qualification Protocols and Instructions. Experion Automated Electrophoresis Station and Software

Guido Baum Phone: +49(0) Mail:

ISO A Standard Methodology to Optical Particle Counter Calibration and What It Means to Cleanroom Owners

Computerised Systems. Seeing the Wood from the Trees

ISO 9001:2008 QUALITY MANUAL. Revision B

Epidemiology of HCV and HIV/HCV Infection in Guangzhou, China. Title. Charles Wang, M.D.

Procedure for Equipment Calibration and Maintenance

Basic research methods. Basic research methods. Question: BRM.2. Question: BRM.1

Qualification, calibration and maintenance of stability chambers. Dr. Mathias Kramer

Transcription:

Instrument/Method Validation Lebah Lugalia Lab QA/QC Coordinator UNC Project Lilongwe, Malawi

Instrument/Method Validation QUESTION AND ANSWER PRESENTATION

Instrument Validation What is instrument validation?

Instrument Validation Definition: It is a series of processes through which you test your system to verify or validate the performance specifications published by the manufacturer of the instrument.

Instrument Validation Why is it important to validate the instrument?

Why Validate your instrument/method? It is required by the CLIA regulation (CLIA 42 CFR part 493.1253). International sites participate in DAIDS/NIH funded studies, we must be in compliance with the U.S. regulations. You want to validate the manufacturer s claims for their method performance characteristics, under your current environmental conditions, e.g. temp, humidity, water, electricity, operator skills etc.

Why validate your instrument? You want to ensure that the amount of error present in the system won t affect the interpretation of the test result and compromise patient care. Ensure that effects of shipment and storage did not affect your instrument performance.

Instrument Validation When do you validate your instrument?

When to validate instrument Initial installment of the instrument. When a new method or test is implemented. When a major part is changed e.g. photometer of a chemistry instrument. When an instrument is borrowed. When you MOVE your instrument from one location to another. Annually (if time allows).

Three validation principles IQ, OQ, PQ

IQ- Installation Qualification Installation qualification verifies that the equipment and its subsystems have been installed in accordance to manufacturer s specifications. Usually performed by the company s field representative. Examples: Verification that all components parts are functional Verification that local supply voltages conform to instrument Verify that the ambient conditions exist for optimal instrument performance. Verify correct versions of software were issued with the instrument. Setting up of instrument parameters (date, time, language, test protoc.

OQ- Operation Qualification This validation provides evidence that the instrument operates as expected and confirms that installation was successful. Done by the field representative and lab technicians. Training of instrument operation. Testing of controls, calibrators and a few patient samples.

Instrument Validation - PQ What experiments are performed in Performance Qualification (Method Validation)?

Instrument Validation - Experiments Precision (Replication) Linearity (to verify reportable range) Accuracy (correlation or comparison) Reference Intervals (Normal values) Analytical Sensitivity Analytical Specificity

Instrument Validation What are CLIA guidelines for validation?

CLIA Regulations CLIA regulations are based on the complexity of the test method. 3 categories: 1. Waived tests does not require validation. 2. Non-waived unmodified tests moderate and high complexity tests needs validation. 3. Non-waived, modified (or in-house developed) tests validation is required. Information about classification of specific tests is available at : http://www.cms.gov./clia/

Instrument Validation - Linearity Definition of Linearity?

Instrument Validation- Linearity Linearity or AMR(analytical measurement range) is an assessment of the lowest and highest levels at which an analyte can be accurately measured without any type of dilution or concentration. It is important to validate the manufacturer s claims for reportable range of their system/method.

Instrument Validation- Precision Definition of Precision?

Instrument Validation- Precision Definition Precision is the degree of reproducibility among several independent measurements of the same sample for the same analyte.

Instrument Validation- Precision Precision experiment is performed to estimate the imprecision or random error of the analytical method. Precision is measured in terms of coefficient of variation (CV) and standard deviation (SD). The smaller the CV and SD, the better the precision.

Instrument Validation - Accuracy Define Accuracy?

Instrument Validation - Accuracy Definition: A measurement of the exactness of an analytical method, or the closeness of agreement between the measured value and the true value.

Instrument Validation - Accuracy Performed to estimate inaccuracy or systematic error of the new method. Experiment is performed by analyzing forty or more patient samples by the new method (test method) and a comparative method, then estimate the systematic errors on the basis of the differences observed between the two methods.

Accuracy/Correlation Experiment Westgard has a set of statistical tools on the internet to help calculate the statistics: www.westgard.com/mvtools.html

Reference Range Intervals or NRR Definition of a Reference Range Intervals?

Reference Range Intervals or NRR Definition: Reference ranges are a measured set of values determined to occur in a healthy nondiseased population.

Reference Range Intervals or NRR Why should you validate the manufacturer s reference intervals or establish your own NRR?

Reference Range Intervals or NRR Differences in demographics of your population due to environmental or genetic factors. Differences in test methods and instruments.

HPTN 035 and MTN 015 protocol required tests What validation exercises are required for: 1. ALP, ALT, AST, T.Bil and Creatinine? 2. CBC/DIFF? 3. CD4? 4. APTT, PT, INR? 5. RPR/TPHA? 6. HIV ELISA? 7. Western Blot?

HPTN 035 and MTN 015 protocol required tests 8. RNA PCR? 9. Probe-Tec CT/GC? 10. HIV Rapid Tests? 11. HSV-2?

Validation Summary Need to write up a validation summary and file together with results data in a binder. Report should be signed by performing technician and lab Manager/Director or designee. Submit validation data and summary to Network Lab for approval.

Reasons why we don t validate our instruments/methods? Discussion

NEW METHOD BC CX-5 PRO

NEW METHOD BC CX-5 PRO

REFERENCES Method Validation by Westgard HPTN Lab Manual by Network Lab