Flow Cytometry. CLIA Compliance Manual*
|
|
|
- Grant Bennett
- 10 years ago
- Views:
Transcription
1 Flow Cytometry CLIA Compliance Manual* Revised for the International Society for Advancement of Cytometry (ISAC) and Clinical Cytometry Society (CCS) By Michael Keeney ART, FIMLS Teri Oldaker B.A., CLS(NCA)QCYM (ASCP) ^Second Edition * This document does not constitute the rendering of legal or other professional advice and is provided 'as is' with no express or implied warranty of correctness, merchantability, or fitness or suitability for any particular purpose or use. ISAC is not responsible or liable for any adverse consequences that may arise from the use of, or reliance on, this document. ^ "1st Edition The first edition of this manual was commissioned for the Purdue CDROM Vol 3, 1997 and was written by A. Hurley and D. Zito.
2 Preface The 105 th Congress of the United States, convened after the January 1997 inauguration of President Clinton, considered many issues affecting clinical laboratory science in general and cytometry laboratories in particular. Conformation to the provisions of the Clinical Laboratory Improvement Act (CLIA), Medicare fee schedule changes, manpower funding, and reimbursement issues all came under Congressional scrutiny. After a series of revisions, the CLIA Final Rule (42 CFR Part 493 (68 FR:3640) was published in January 2003 and implemented April 24, Minor changes were incorporated in There are changes relating to Quality Systems and Personnel Requirements. In addition, there are consolidations around requirements for patient test management and changes in grading for proficiency testing. Because of this fluid regulatory environment, the Flow Cytometry CLIA Compliance Manual has been written to help make sense of the CLIA requirements and give laboratories a clear format by which to monitor Quality Assessment (previously Quality Assurance) and Quality Control. This manual outlines the updated compliance requirements for clinical laboratories engaged in the practice of flow cytometry, which is now considered non-waived testing (previously high complexity). Only the personnel requirements continue to stratify the high complexity and moderate complexity categorization. In recent years, the complexity of flow cytometry assays has increased significantly, particularly in relation to the number of simultaneous measurements that can now be made. Areas of spectral overlap, accuracy of data collection, cluster identification automation, and approaching issues of complex data processing can cause many problems if not addressed appropriately. Since the legislative requirements are based on the complexity of the laboratory testing, recommendations in this manual apply to non-waived testing; instructions and forms are provided for complying with the personnel, quality control, proficiency testing, and quality assessment requirements. ISAC and CCS play an important role in all aspects of laboratory management, establishment of standards as well as training and education for the field of cytometry. There is no substitute for well documented processes, assays and results reporting. All documents of this nature are living documents and we encourage you to participate in the identification of areas that can be updated or modified to improve clarity, accuracy or relevance. The ISAC Education Task Force in conjunction with CCS has developed an updated version of this manual to incorporate the final CLIA revisions. We hope the information put forth here will help cytometry laboratories meet these regulatory requirements with greater ease, so that they may focus with more intensity on the quality of patients' results. While every effort has been made to ensure the accuracy of this document, the 2004 Codification is the definitive document. The current link to this document is:
3 I. Introduction II. Overview of the Rules Defining the Final CLIA Federal Regulation with changes to 2004 A. Subpart I Proficiency Testing for Non-waived testing B. Subpart J Facility Administration for Non-waived testing C. Subpart K Quality Systems for Non-waived testing D. Subpart M Personnel Non-waived testing E. Subpart Q Inspection F. Subpart T Consultations III. Flow Cytometry Specific Compliance A. Proficiency Testing B. Quality Control C. Quality Assessment Documentation IV. Example Forms that can be used in Flow Cytometry 1) Form 1 Proficiency Testing (PT) Survey Listing & Participation Summary 2) Form 2 Proficiency Testing (PT) Processing, Enrollment, and Testing of Samples: Flow Cytometry 3) Form 3 Remedial Action: Unacceptable Proficiency Testing Results, Flow Cytometry 4) Form 4 Quality Assessment Review: Evaluation of Corrective Actions on Unsatisfactory Proficiency Testing Results 5) Form 5a Cytometry Equipment and Function Checks 6) Form 5b Laboratory Equipment and Function Checks 7) Form 5c Corrective Action: Preventive Maintenance and Function Checks 8) Form 5d Equipment Service Log 9) Form 6 Pipette Calibration 10) Form 7 Adequacy of Methods/Equipment/Instruments for Testing 11) Form 8 Quality Control 12) Form 9 Remedial Action: Test Results Reported in Error 13) Form 10 Criteria for Specimen Collection and Handling 14) Form 11 Evaluation of Criteria for Specimen Rejection 15) Form 12 Completeness of Information on Requisitions and Reports 16) Form 13 Quality Assessment for Quality Control Corrective Action 17) Form 14 Relationship between Test Results Using Different Methods, Instruments, or Testing Sites 18) Form 15 Evaluation of Patient Test Results Inconsistent with Patient Criteria 19) Form 16 Employee Qualification Documentation 20) Form 17 Employee Competence Review Flow Cytometry 21) Form 18 Documentation of Complaints and Problems Reported to Laboratory 22) Form 19 Quality Assessment Review with Staff
4 Introduction This manual will outline key areas for clinical laboratories engaged in the practice of flow cytometry abstracted from the Final Rule of the Clinical Laboratory Improvement Act (CLIA) compliance requirements through The legislation requirements are based on the complexity of the laboratory testing. Flow cytometry is considered high complexity testing; however, the revised CLIA document combines the moderate and high complexity testing in to one category; non-waived tests. The only area where high complexity testing is singled out is in the Personnel area. The recommendations in this manual will apply to non-waived testing and will give information and example forms for complying with the personnel, quality control, proficiency testing, and quality assessment requirements.
5 Subpart H Participation in Proficiency Testing (PT) for Laboratories Performing Non-waived Tests Condition: Enrollment and Testing of Samples Each laboratory performing non-waived tests must enroll in a proficiency testing program that meets the CLIA federal regulation (Subpart I) and is approved by Health and Human Services (HHS). The laboratory must enroll in an approved program or programs for each of the specialties or subspecialties for which certification is desired. All of the usual criteria for running proficiency testing samples must be adhered to, including running each test sample as a patient. Under the regulation (a) Standard; Enrollment, the laboratory is required to: Inform HHS of the approved programs in which it has chosen to participate. The laboratory must also list the tests performed and which PT programs will satisfy this requirement. For tests that are not covered under PT programs, the laboratory must establish and maintain the accuracy and reliability of its testing procedures in accordance with section The laboratory must also participate in the approved program or programs for one year for each specialty or test before choosing a different program and must notify CMS before the change. The last requirement under this Standard asks the laboratory to authorize the PT program to release to HHS all data necessary to determine the laboratory s compliance. Under the regulation (b) Standard; Testing of Proficiency Testing Samples, the laboratory is required to: Test or examine the PT samples it receives with the regular patient workload by personnel who routinely perform the testing using the usual methods. The laboratory must handle and test PT samples the same number of times it routinely tests patient samples. Additionally, the laboratory must not discuss PT sample results with any other laboratory until after the results are required to be sent to the service. This also applies to laboratories with multiple sites. If a laboratory performs a certain test, it must not send the PT sample to another laboratory for analysis and then report those results. Laboratories who engage in this practice will have their certification revoked for at least one year. The laboratory must follow standard practices by documenting the handling, preparation, processing, examination, and each step in the testing and reporting of results for all PT samples. Copies of the PT report forms (with the signatures of the analyst and laboratory director) must be kept for a minimum of two years after the PT event. Only the primary method for patient testing requires PT data.
6 Condition: Successful Participation Each laboratory performing non-waived tests must successfully participate in a PT program approved by CMS, if applicable. If the laboratory fails the PT program for any specialty, subspecialty, analyte, or test, sanctions will be taken. The proficiency testing grading requirement is 80% consensus among participating laboratories Condition: Reinstatement of Laboratories Performing Non-waived Tests After Failure to Participate Successfully. The termination period for Medicare/Medicaid approval or period for suspension of certification under CLIA for the failed test, is a period of not less than six months. If the laboratory s certificate is suspended or Medicare/Medicaid approval is withdrawn for failing PT for one or more tests, or if the laboratory voluntarily withdraws its certification, the laboratory must demonstrate successful performance on two consecutive PT events (one of which may be onsite) before CMS will consider it for reinstatement. NOTE: Please refer to the CLIA regulation, Proficiency Testing by Specialty or Subspecialty for Laboratories Performing Non-waived Tests for the specific parameters required for successful PT performance.
7 Subpart I Proficiency Testing Programs for Non-waived Tests Approval of proficiency testing programs A PT program must be offered by a private, nonprofit organization, a Federal or State agency or its designee in order to receive HHS approval. The organization must submit its application for approval or re-approval for the next calendar year by July 1 of the current year. It must also provide technical assistance to laboratories which desire to qualify under the program. Additionally, the organization must assure the quality of test samples, evaluate and score the results, and identify performance deficits. Overall technical ability must be demonstrated to HHS. This includes: the preparation or purchase of samples made under good manufacturing practices; the adequate distribution of samples, with special consideration given to patient similarity, homogeneity, and stability; and mechanisms to provide adequate information to HHS and the PT participant on grading criteria, technical and administrative concerns Administrative responsibilities. The proficiency testing program must provide HHS or its designees and participating laboratories with an electronic or a hard copy, or both, of reports of proficiency testing results and all scores for each laboratory's performance within 60 days after the date by which the laboratory must report proficiency testing results to the proficiency testing program. The program also must furnish to HHS cumulative reports on an individual laboratory's performance and aggregate data for the purpose of establishing a system to make the proficiency testing program's results available, on a reasonable basis, upon request of any person, and include such explanatory information as may be appropriate to assist in the interpretation of the proficiency testing program's results. The program must provide HHS with an annual report and, if needed, an interim report which identifies any previously unrecognized sources of variability in kits, instruments, methods, or PT samples, which adversely affect the programs' ability to evaluate laboratory performance Non-approved proficiency testing programs. If a proficiency testing program is determined by HHS to fail to meet any criteria contained in Secs through for approval of the proficiency testing program, CMS will notify the program and the program must notify all laboratories enrolled of the non-approval and the reasons for non-approval within 30 days of the notification.
8 Subpart J Facility Administration for Non-waived testing Standard; Facilities The laboratory must be constructed to ensure an appropriate environment to enable the proper performance of all phases of testing (pre-analytic, analytic, and post-analytic). Safety precautions must be followed to ensure protection from biohazardous materials, and from electrical or physical hazards Standard: Retention requirements The laboratory must retain its records and, as applicable, slides, blocks, and tissues as follows: Test requisitions and authorizations. Retain records of test requisitions and test authorizations, including the patient's chart or medical record if used as the test requisition or authorization, for at least 2 years. Test procedures. Retain a copy of each test procedure for at least 2 years after a procedure has been discontinued. Each test procedure must include the dates of initial use and discontinuance. Analytic systems records. Retain quality control and patient test records (including instrument printouts, if applicable) and all analytic systems activities specified in through for at least 2 years*. In addition, retain records of test system performance specifications that the laboratory establishes or verifies for the period of time the laboratory uses the test system but no less than 2 years. Proficiency testing records. Retain all proficiency testing records for at least 2 years. Laboratory quality systems assessment records. Retain all laboratory quality systems assessment records for at least 2 years. Test reports. Retain or be able to retrieve a copy of the original report (including final, preliminary, and corrected reports) at least 2 years after the date of reporting. If the laboratory ceases operation, the laboratory must make provisions to ensure that all records and, as applicable, slides, blocks, and tissue are maintained and available for the time frames specified in this section. *Note: Flow cytometry dot plots and gated histograms must be stored for 10 years (CAP). Electronic listmode files are acceptable, providing the analysis gates used to derive the results are imbedded within the file.
9 Subpart K Quality Systems for Non-waived Testing The section has been revised in 2003 to incorporate quality assessment (previously quality assurance), quality control, and general laboratory systems, which include pre-analytic, analytic and post analytic processes. It also combines moderate complexity and high complexity testing into non-waived tests Introduction (a) Each laboratory that performs non-waived testing must establish and maintain written policies and procedures that implement and monitor quality systems for all phases of the total testing process (that is, pre-analytic, analytic, and post-analytic) as well as general laboratory systems. (b) Each of the laboratory's quality systems must include an assessment component that ensures continuous improvement of the laboratory's performance and services through ongoing monitoring that identifies, evaluates and resolves problems. (c) The various components of the laboratory's quality systems are used to meet the requirements in this part and must be appropriate for the specialties and subspecialties of testing the laboratory performs, services it offers, and clients it serves. General Laboratory Systems Condition: General laboratory systems Each laboratory that performs non-waived testing must meet the applicable general laboratory systems requirements in Sec through , unless HHS approves a procedure, specified in Appendix C of the State Operations Manual (CMS Pub. 7), that provides equivalent quality testing. The laboratory must monitor and evaluate the overall quality of the general laboratory systems and correct identified problems as specified in Sec for each specialty and subspecialty of testing performed Standard: Confidentiality of patient information The laboratory must ensure confidentiality of patient information throughout all phases of the total testing process that are under the laboratory's control Standard: Specimen identification and integrity
10 The laboratory must establish and follow written policies and procedures that ensure positive identification and optimum integrity of a patient's specimen from the time of collection or receipt of the specimen through completion of testing and reporting of results Standard: Complaint investigations The laboratory must have a system in place to ensure that it documents all complaints and problems reported to the laboratory. The laboratory must conduct investigations of complaints, when appropriate Standard: Communications The laboratory must have a system in place to identify and document problems that occur as a result of a breakdown in communication between the laboratory and an authorized individual who orders or receives test results Standard: Personnel competency assessment policies As specified in the personnel requirements in subpart M, the laboratory must establish and follow written policies and procedures to assess employee and, if applicable, consultant competency Standard: Evaluation of proficiency testing performance The laboratory must review and evaluate the results obtained on proficiency testing performed as specified in subpart H of this part. The laboratory must verify the accuracy of the following: Any analyte or subspecialty without analytes listed in subpart I of this part that is not evaluated or scored by a CMS-approved proficiency testing program or any analyte, specialty or subspecialty assigned a proficiency testing score that does not reflect laboratory test performance (that is, when the proficiency testing program does not obtain the agreement required for scoring as specified in subpart I of this part, or the laboratory receives a zero score for nonparticipation, or late return of results). At least twice annually, the laboratory must verify the accuracy of the following: any test or procedure it performs that is not included in subpart I of this part, or any test or procedure listed in subpart I of this part for which compatible proficiency testing samples are not offered by a CMS-approved proficiency testing program. All proficiency testing evaluation and verification activities must be documented Standard: General laboratory systems assessment The laboratory must establish and follow written policies and procedures for an ongoing mechanism to monitor, assess, and, when indicated, correct problems identified in the general laboratory system requirements specified at Sec. Sec through
11 The general laboratory systems assessment must include a review of the effectiveness of corrective actions taken to resolve problems, revision of policies and procedures necessary to prevent recurrence of problems, and discussion of general laboratory systems assessment reviews with appropriate staff. The laboratory must document all general laboratory systems assessment activities. Pre-analytic Systems Condition: Pre-analytic systems Each laboratory that performs non-waived testing must meet the applicable pre-analytic system(s) requirements in Sec. Sec and , unless HHS approves a procedure, specified in Appendix C of the State Operations Manual (CMS Pub. 7), that provides equivalent quality testing. The laboratory must monitor and evaluate the overall quality of the pre-analytic systems and correct identified problems as specified in Sec for each specialty and subspecialty of testing performed Standard; Test Requisition Tests are performed by a laboratory only at the written or electronic request of an authorized person. Verbal requests must be followed by written or electronic authorization within 30 days. The test requisitions (or equivalent) must be retained for a minimum of two years. Each requisition must include: a unique patient identifier, any suitable identifiers of the requesting party, the tests to be performed, and the date and time of specimen collection , Standard; Procedures for Specimen Submission and Handling Each laboratory must have written policies and procedures (readily available) for all methods. These include: preparation of patients, specimen collection, specimen labeling, specimen preservation, and specimen transportation. If the laboratory accepts referral specimens, the above information must be supplied to their clients Standard: Pre-analytic systems assessment The laboratory must establish and follow written policies and procedures for an ongoing mechanism to monitor, assess, and when indicated, correct problems identified in the preanalytic systems. The pre-analytic systems assessment must include a review of the effectiveness of corrective actions taken to resolve problems, revision of policies and procedures necessary to prevent recurrence of problems, and discussion of pre-analytic systems assessment reviews with appropriate staff. The laboratory must document all pre-analytic systems assessment activities. Analytic Systems Condition: Analytic systems
12 Each laboratory that performs nonwaived testing must meet the applicable analytic systems requirements. The laboratory must monitor and evaluate the overall quality of the analytic systems and correct identified problems Standard: Procedure manual A written procedure manual for the performance of all analytical methods used by the laboratory must be readily available and followed by laboratory personnel. Procedures may be organized in the form of manuals, computer memory, or card files. Manufacturer s operating instructions, package inserts, and other manuals (CDC or AFIP) are acceptable as long as the procedures are clearly indicated. The procedure manual must include: requirements for specimen collection, processing and specimen rejection criteria, step-by-step performance of the procedure, preparation of solutions, calibrators, controls and reagents, calibration and calibration verification procedures, the reportable range for test results, and control procedures. The procedure manual must also include the remedial action required when calibration or control results fall outside the laboratory s acceptability criteria. Defined reference ranges, panic values, literature references, criteria for specimen storage and the laboratory s system for reporting patient results must be clearly documented and available to all laboratory personnel. Procedures must be approved, signed, and dated by the director prior to implementation and must be reapproved if the director changes. The laboratory must maintain a copy of each procedure in a secure location with the date of the initial use and discontinuance for a minimum of 2 years after a procedure has been discontinued Standard: Test systems, equipment, instruments, reagents, materials, and supplies Accurate and reliable results must be obtained by ensuring that the equipment and methodologies are performed within the laboratory s stated performance specifications. A laboratory must define criteria for conditions essential for proper storage of reagents, specimens and accurate and reliable test system operation and test result reporting. Such conditions may include: water quality, temperature, humidity and electrical current fluctuation protection. Any remedial actions must be documented. Reagents, solutions, culture media, control materials, calibration materials and other supplies must be labeled for: identity and titer or concentration, recommended storage requirements, preparation and expiration dates. The laboratory must comply with FDA product dating requirements and not use materials when they have exceeded their expiration date. Additionally, the laboratory must not interchange components of reagent kits of different lot numbers unless so specified by the manufacturer Standard: Establishment and verification of performance specifications Before a laboratory can report patient results, it must verify or establish performance specifications for accuracy, precision, sensitivity and specificity (if applicable), the reportable
13 range of patient test results, the normal values, and any other applicable performance characteristics. Laboratories are required to verify or establish performance criteria for a test method in use after April 23, Laboratories are not required to verify or establish performance specifications for any test system used by the laboratory before April 24, 2003 The laboratory must determine and establish the test systems calibration and control procedures for monitoring and evaluating the quality of the analytical testing process of each method to assure the accuracy and reliability of patient test results and reports. The responsibility for quality now rests on the laboratory as there is no longer FDA clearance of QC. The laboratory is responsible for having control procedures that monitor the complete analytical process, take into account the performance specifications of the method, detect immediate errors, and monitor long term precision and accuracy. For each non-waived test, the laboratory must meet all applicable standards of this subpart. For each non-waived test performed using a method developed in-house or using an instrument, kit or test system cleared by the FDA through the premarket notification (510(k)) or premarket approval (PMA) process but modified by the laboratory, the laboratory must meet all applicable standards of this subpart. However, for all other non-waived tests performed using an instrument, kit or test system cleared by the FDA for in-vitro diagnostic use the laboratory must: 1. Follow the manufacturer s instructions for instrument or test system operation and test performance 2. Have a written procedure manual describing the processes for testing and reporting patient test results 3. Perform and document calibration and calibration verification procedures at least once every six months
14 4. Perform and document quality control procedures using at least two levels of control materials each day of testing 5. Perform and document applicable specialty and subspecialty control procedures as specified under Perform and document that remedial action has been taken when problems or errors are identified as specified in Electronic, mechanical, and operational checks must be performed by the laboratory to ensure proper performance and accurate test results. For equipment cleared by the FDA, the laboratory must perform and document the maintenance as defined by the manufacturer with at least the frequency specified. For equipment not cleared by the FDA or for equipment, instruments, or systems developed or modified in-house, the laboratory must establish and document a maintenance protocol which includes frequency of testing. In like manner, for equipment cleared by the FDA the laboratory must perform function checks as defined and with at least the frequency recommended. For equipment not cleared, or in-house modified or developed systems, the laboratory must define and document a function check protocol Standard; Calibration and Calibration Verification Procedures Calibration is the process of testing and adjusting an instrument or test system to provide a known relationship between the measurement response and the value of the substance that is being measured by the test procedure. Calibration verification is the assaying of calibration materials in the same manner as patient samples to confirm that the calibration of the instrument or test system has remained stable throughout the laboratory's reportable range for test results. Calibration and calibration verification must be performed and documented. For test procedures that are performed on test systems that have been cleared by the FDA, the laboratory must follow the manufacturer's directions at a minimum. For procedures developed or modified in-house, or systems not cleared by the FDA the laboratory must establish calibration procedures in accordance with criteria established by the laboratory. This criterion should include: the number, type and concentration of calibration materials, acceptable limits for calibration, frequency of calibration, and the appropriate calibration materials that are traceable to a reference method or reference material, if possible. Additionally, calibration must be performed when calibration verification fails to meet the laboratory's acceptable limits. Calibration verification procedures must be performed with the manufacturer's instructions, or in accordance with criteria established by the laboratory. The calibration materials must be appropriate for verifying the laboratory's established reportable range of patient results which must include at least a minimal (or zero) value, a mid-point value, and a maximum value at the upper limit of that range. Calibration verification must also be performed at least once every six months or when a complete change of reagents for a procedure is introduced (unless the laboratory can demonstrate that the change does not affect the reportable range), when major preventive maintenance requires the replacement of critical parts that may influence test performance, and when the controls demonstrate an unusual trend or shift. All calibration and calibration verification procedures that are performed must be documented.
15 Standard; Control Procedures The accuracy and precision of patient test results are indirectly assessed through use of control procedures and control and calibration materials. For each method cleared by the FDA, the laboratory must follow the manufacturer's instructions. For methods developed or modified inhouse, or not cleared by the FDA, the laboratory must evaluate instrument and reagent stability and operator variance in determining the number, type and frequency of testing calibration and control materials and establish acceptability criteria used to monitor test performance during a patient specimens run. (A run is an interval within which accuracy and precision of a testing system is expected to be stable, but cannot be greater than 24 hours.) For qualitative tests, the laboratory must include a positive and negative control with each run of patient specimens. This can be commercial, previously tested samples or internal controls. For quantitative tests, the laboratory must include at least two samples of different concentrations of either calibration materials, control materials, or a combination, with a frequency of not less than once each run of patient specimens. The laboratory must have an alternative mechanism to assure the validity of patient results if calibration and control materials are not available. Control samples must be tested in the same manner as patient samples and results must meet the laboratory's acceptability criteria. When calibration or control materials are used, statistical values such as mean and standard deviation must be determined through repetitive testing. The manufacturer's stated values of an assayed control may be used, or, if unassayed materials are used, the laboratory must establish these values through concurrent testing with previously determined values of calibration or control materials Standard: Comparison of test results If a laboratory performs the same test using different methodologies or instruments, or performs the same test at multiple testing sites, the laboratory must have a system that twice a year evaluates and defines the relationship between test results using the different methodologies, instruments, or testing sites. The laboratory must have a system to identify and assess patient test results that appear inconsistent with the following relevant criteria, when available: Patient age, sex,.diagnosis or pertinent clinical data, and relationship with other test parameters. The laboratory must document all test result comparison activities Standard: Corrective actions Corrective action policies and procedures must be available and followed as necessary to maintain the laboratory's operation for testing patient specimens in a manner that ensures accurate and reliable patient test results and reports. The laboratory must document all corrective actions taken, including actions taken when any of the following occur: test systems do not meet the laboratory's verified or established performance specifications., which include but are not limited to--equipment or methodologies that perform outside of established operating parameters or performance specifications; patient test values that are outside of the laboratory's reportable range of test results for the test system; and when the laboratory determines that the reference intervals for a test procedure are inappropriate for the laboratory's patient population,
16 results of control or calibration materials, or both, fail to meet the laboratory's established criteria for acceptability. All patient test results obtained in the unacceptable test run and since the last acceptable test run must be evaluated to determine if patient test results have been adversely affected. The laboratory must take the corrective action necessary to ensure the reporting of accurate and reliable patient test results Standard; Test Records A record system must be maintained by the laboratory to ensure reliable identification of patient specimens (and the testing personnel) as they are processed and tested. Records, including instrument printouts if applicable, must be retained for a minimum of two years. These records must include: a unique patient identifier, the date and time the specimen arrived at the laboratory, the disposition of specimens that do not meet the laboratory s acceptability criteria, and the dates of all specimen testing. Laboratories are now required to retain flow cytometry dot plots and histograms for 10 years. (College of American Pathologists).Electronic listmode files are acceptable, providing the analysis gates used to derive the results are embedded within the file Standard: Analytic systems assessment The laboratory must establish and follow written policies and procedures for an ongoing mechanism to monitor, assess, and when indicated, correct problems identified in the analytic systems. The analytic systems assessment must include a review of the effectiveness of corrective actions taken to resolve problems, revision of policies and procedures necessary to prevent recurrence of problems, and discussion of analytic systems assessment reviews with appropriate staff. The laboratory must document all analytic systems assessment activities.
17 Post Analytical Systems Condition: Post-analytic systems Each laboratory that performs non-waived testing must meet the applicable post-analytic systems requirements. The laboratory must monitor and evaluate the overall quality of the postanalytic systems and correct identified problems for each specialty and subspecialty of testing performed Standard; Test Report The laboratory report must be sent promptly to the requesting individual or party. A copy of each report must be maintained by the laboratory for timely accessibility and for a minimum of two years. The test report must indicate the name and address of the laboratory location, the test performed, the test result, date of test report and, if applicable, specimen source, interpretation and/or the units of measurement. Pertinent reference or normal ranges, determined by the laboratory performing the tests, must be available to the requester. Additionally, the laboratory must develop and follow written procedures for reporting imminent life-threatening test results or panic values. If requested by its clients, the laboratory must provide a list of test methods employed and the performance specifications Standard: Post-analytic systems assessment The laboratory must establish and follow written policies and procedures for an ongoing mechanism to monitor, assess and, when indicated, correct problems identified in the postanalytic systems. The post-analytic systems assessment must include a review of the effectiveness of corrective actions taken to resolve problems, revision of policies and procedures necessary to prevent recurrence of problems, and discussion of post-analytic systems assessment reviews with appropriate staff. The laboratory must document all post-analytic systems assessment activities.
18 Subpart M Personnel for Non-waived Testing NOTE: Personnel requirements are the only area where there is delineation between high and moderate complexity testing. This is based on a weighted system that reviews the following attributes of the testing: knowledge, training and experience, characteristics of the operational steps, calibration, QC, and PT materials, troubleshooting and maintenance, interpretation and judgment. Flow cytometry testing is classified as high complexity testing. This revision is effective as of February 24, General This subpart consists of the personnel requirements that must be met by laboratories performing non-waived testing Condition: Laboratories Performing Non-waived, (High Complexity Testing); Laboratory Director The laboratory must have a director who meets the qualification requirements and provides overall management and direction Standard; Laboratory Director Qualifications The laboratory director must possess a current license as a director issued in the state in which the laboratory is located, if such is required. The director may be a doctor of medicine or osteopathy licensed to practice in that state and be certified in anatomic or clinical pathology or both or possess qualifications that are equivalent to those required for such certification. The director may also be a doctor of medicine or osteopathy duly licensed and have at least one year of laboratory training during residency or at least 2 years experience directing high complexity testing. The director may also hold an earned doctoral degree in a chemical, physical, biological, or clinical laboratory science from an accredited institution and be appropriately certified by a board approved by the HHS. Alternative qualifications include 2 years of laboratory training and 2 years laboratory experience directing or supervising high complexity prior to February 24, Standard; Laboratory Director Responsibilities The laboratory director is responsible for the overall operation of the laboratory including employing acceptable personnel. The director may perform the duties of the technical consultant, clinical consultant, and testing personnel or delegate these to the appropriate personnel. The director must ensure that testing systems developed and used provide quality services that the physical plant conditions are appropriate for the testing performed, that the test methodologies
19 will provide quality results, that verification procedures are adequate, and that personnel are performing the tests as required. The director must also ensure that the laboratory is enrolled in an HHS approved PT program and that the QC and QA programs are established and maintained to assure quality and identify failures as they occur. Additionally, the director must ensure remedial action is taken when necessary, that consultation is available to the laboratory's clients, that sufficient laboratory personnel with the appropriate education and experience are performing the tests, that policies are established for monitoring personnel to assess their competency, that an approved procedure manual is available, and that the responsibilities of each person are specified. The director must also ensure that a general supervisor provides on-site supervision of non-waived test performance Condition: Laboratories Performing Non-waived, (High Complexity Testing); Technical Supervisor The laboratory must have a technical supervisor who meets qualification requirements and provides technical supervision Standard; Technical Supervisor Qualifications (TS) Individuals who are qualified by education and experience to provide technical supervision for the performed services must be employed by the laboratory. The TS must possess a current license issued in the state in which the laboratory is located, if such is required. The TS may be a doctor of medicine or osteopathy licensed to practice in that state and be certified in anatomic or clinical pathology or both or possess qualifications that are equivalent to those required for such certification. NOTE: Please refer to the CLIA regulation, for the applicable qualification requirements for the specific high complexity subspecialties for the technical supervisor Standard; Technical Supervisor Responsibilities The technical supervisor is responsible for the technical and scientific oversight of the laboratory. The TS is not required to be on-site at all times testing is performed, but must be available on an as-needed basis. The TS is responsible for the selection of the appropriate test methodology, ensuring that verification procedures are established. The TS must also ensure that the laboratory is enrolled in an HHS approved PT program and establish the QC and QA programs to assure quality and identify failures as they occur. Additionally, the TS must ensure remedial action is taken when necessary, resolve technical problems, ensure that each individual performing tests receives regular in-service training, and evaluate the competency of all testing personnel. Technical Supervisor Responsibilities: Evaluating the competency of all testing personnel and assuring that the staff maintain their competency to perform test procedures and
20 report test results promptly, accurately and proficiently. The procedures for evaluation of the competency of the staff must include, but are not limited to- (i) (ii) (iii) (iv) (v) (vi) Direct observations of routine patient test performance, including patient preparation, if applicable, specimen handling, processing and testing; Monitoring the recording and reporting of test results; Review of intermediate test results or worksheets, quality control records, proficiency testing results, and preventive maintenance records; Direct observation of performance of instrument maintenance and function checks; Assessment of test performance through testing previously analyzed specimens, internal blind testing samples or external proficiency testing samples; and Assessment of problem solving skills. Evaluating and documenting the performance of individuals responsible for high complexity testing at least semiannually during the first year the individual tests patient specimens. Thereafter, evaluations must be performed at least annually unless test methodology or instrumentation changes, in which case, prior to reporting patient test results; the individual s performance must be reevaluated to include the use of the new test methodology or instrumentation Condition: Laboratories Performing Non-waived, (High Complexity Testing); Clinical Consultant The laboratory must have a clinical consultant who meets the qualification requirements and provides clinical consultation Standard; Clinical Consultant Qualifications (CC) The CC must be qualified to consult with and render opinions to the laboratory's clients concerning the diagnosis, treatment and management of patient care. The CC must be qualified as a laboratory director, or be a doctor of medicine or osteopathy and possess a license to practice in the state in which the laboratory is located.
21 Standard; Clinical Consultant Responsibilities The CC provides consultation regarding the appropriateness of the tests ordered and the interpretation of results. This includes being available to the laboratory's clients to assist with choosing the appropriate tests and that the patient reports contain the pertinent information necessary for specific patient interpretation Condition: Laboratories Performing Non-waived (High Complexity Testing); General Supervisor (GS) The laboratory must have one or more general supervisors who are qualified to provide general supervision. The GS provides day-to-day supervision of testing personnel and reporting of test results under the direction of the laboratory director and the technical supervisor. The GS must possess a current license issued by the state where is laboratory is located, if required, be a laboratory director, or a technical supervisor. NOTE: Please refer to the CLIA regulation, for the applicable qualification requirements for the specific high complexity subspecialties for the general supervisor Standard: General Supervisor Responsibilities The GS must be available to testing personnel at all times testing is performed (on-site, telephone, or electronic). The GS is responsible for providing day-to-day supervision of high complexity test performance by testing personnel, and monitoring test analyses and specimen examinations to ensure acceptable levels of analytic performance are maintained. If the director or TS chooses, the GS assures all remedial actions are taken, ensures results are not reported until the test system is properly functioning, provides orientation to testing personnel, and annually evaluates and documents personnel performance Condition: Laboratories Performing Non-waived, (High Complexity Testing); Testing Personnel The laboratory must have a sufficient number of individuals who meet the qualification requirements Standard; Testing Personnel Qualifications Each individual must possess a current license issued in the state where the laboratory is located, if required, be a doctor of medicine or osteopathy duly licensed, have earned a doctoral, master's or bachelor's degree in a chemical, physical, biological or clinical laboratory science, or medical technology from an accredited institution, have earned an associate degree in a chemical, physical, biological or medical laboratory technology from an accredited institution.
22 NOTE: Please refer to the CLIA regulation, for the applicable qualification requirements for the specific high complexity subspecialties for testing personnel Standard; Testing Personnel Responsibilities Testing personnel are responsible for specimen processing, test performance, and reporting test results. Each individual performs only those high complexity tests that are authorized by the director and require a degree of skill commensurate with the individual's education, training, and technical abilities. Testing personnel must follow laboratory procedures, maintain records for testing of PT samples, adhere to the laboratory's QC policies, be capable of identifying problems and either corrects them or notify the appropriate person, and document all corrective actions.
23 Subpart Q Inspection Condition: Inspection of Laboratories Issued a Certificate of Waiver An unannounced inspection of the laboratory by HHS or its designee can occur any time. The laboratory must allow HHS: to interview all laboratory employees to assess compliance, to inspect all areas of the facility, to observe employees, and to request data and information in order to determine that testing is performed without public health risk. In addition, the laboratory must provide all records and data that are requested. If the laboratory refuses to permit an inspection, a suspension or termination of Medicare/Medicaid payments, and suspension of or action to revoke the laboratory s CLIA certificate of waiver will ensue Condition: Inspection of All Laboratories Not Issued a Certificate of Waiver or a Certificate of Accreditation HHS or its designee will conduct unannounced inspections at least biennially of any laboratory. HHS will inspect a laboratory possessing a registration certificate before issuance of a certificate. The laboratory may be required to test samples, allow HHS to interview and/or observe employees, inspect the facility, and provide all records and data that are requested (records are retained for at least two years). HHS may re-inspect a laboratory at any time necessary. If the laboratory refuses to permit an inspection, a suspension or termination of Medicare/Medicaid payments, and suspension of or action to revoke the laboratory s CLIA certificate of waiver will ensue Condition: Inspection of Accredited and State-Exempt Laboratories HHS or its designee will conduct unannounced validation inspections and complaint inspections of such laboratories. The laboratory may be required to test samples, allow HHS to interview and/or observe employees, inspect the facility, and provide all records and data that are requested (records are retained for at least two years). HHS may re-inspect a laboratory at any time necessary. If the laboratory refuses to permit an inspection, a suspension or termination of Medicare/Medicaid payments, and suspension of or action to revoke the laboratory s CLIA certificate of accreditation will ensue.
24 Subpart T Consultations Establishment and Function of the Clinical Laboratory Improvement Advisory Committee (CLIAC) A CLIAC will be established by HHS to advise and make technical recommendations concerning criteria for categorizing non-waived, categorizing of waived tests, personnel standards, QA/QC standards, patient test management, PT standards, and applicability of new technology to the standards. This committee will include individuals involved in the provision of laboratory services, utilization of laboratory services, development of test systems or methodologies, or others. Specialized subcommittees may be formed. All committees must meet at least once a year. HHS will be responsible for providing information or data to the CLIAC.
25 Proficiency Testing Agencies College of American Pathologists 325 Waukegan Road Northfield, IL FL Surveys UK NEQAS for Leucocyte Immunophenotyping Rutledge Mews, 3 Southbourne Road, Sheffield, S10 2QN Tel: +44 (0) Fax: +44 (0)
26 Flow Cytometry Quality Control Flow cytometry covers a wide variety of applications ranging from the enumeration of Lymphocyte subsets and CD34 stem and progenitor cells, DNA cell cycle analysis, functional assays and the Leukemia/lymphoma immunophenotyping. The laboratory is responsible for designing a quality control parameters for each type of assay based on the quality requirements, whether it is qualitative or quantitative and the availability of control material. Quality control in flow cytometry includes the following: Instrument QC (Flow cytometer) Other equipment function checks Antibody QC Reagent QC Procedural/Method QC Internal/Patient QC Specimen integrity verifications Instrument (Flow Cytometer) QC: Instrument QC will depend on the flow cytometer manufacturer, make, model and whether the instrument is built for clinical or research use. Generally speaking the instrument manufacturer will set up and optimize the instrument for the lab needs with respect to optical alignment, photomultiplier standardization, sensitivity, linearity and compensation. It is then the laboratory s responsibility to monitor these parameters on a daily basis to ensure instrument stability. This is performed with stable microbeads with measurable fluorescence and light scatter signals in addition to preserved or fresh cells. The optical alignment QC optimizes the sample stream with the path of the laser beam and collection bins. Commercially available microbeads are available for this process. Target values are the brightest and tightest peak for each channel. In other words, the target is the highest fluorescent channel with the lowest %CV (<2%). The standardization QC verifies that flow cytometer has the same fluorescent and light scatter for each protocol each day of use. Commercially available microbeads are available for this process. This can be performed one of two ways; by monitoring the bead mean fluorescent intensity and light scatter channel each day of use and plotting overtime, or instrument software adjusts the PMT voltages to place each fluorescent and light scatter channel in the same position each day, monitoring the changes in voltages and plotting these over time. Monitoring trends or shifts can identify instrument problems. Compensation QC corrects for spectral overlap of one fluorochrome into the fluorescent spectrum of another. Commercially available microbeads are available for this process for some systems. Many applications require further optimization with preserved or fresh cells.
27 Linearity/sensitivity QC verifies that each detector has a linear response. It also verifies the ability to distinguish dim positive signal from negative signal. Commercially available microbeads are available for this process. Acceptability criteria will depend on the application. Other equipment function checks All other equipment used in the flow cytometry laboratory must have manufacturers recommended function checks performed and documented. This includes temperature verification of temperature dependent equipment, centrifuge RPM verification, certification, of biohazard containment hoods, pipette calibration, etc. All function checks must be recorded and if out of an acceptable range, corrective action taken and documented prior to using the equipment. Antibody QC The purpose of this QC is to verify the antibody reactivity from lot to lot is consistent and also to verify the antibodies are labeling the target population as expected. (see procedural QC). Each new antibody lot must be tested for equivalency prior to use. One can use previously tested patient samples, cultured cells or commercial controls. Defined acceptability criteria must be attained and documented. Reagent QC Other critical reagents used in flow cytometry should be verified for equivalency prior to putting a new lot in use. Phasing in selected reagents will depend on the application and is determined by the laboratory director. Defined acceptability criteria must be attained and documented. Procedural/Method QC A procedural/method control is used to verify the entire analytical testing process is controlled each day of use. This control can also assess compensation and serve as an antibody QC. For quantitative assays such as CD34 and lymphocyte subsets, commercial controls are recommended with two levels; one normal and one at a clinical decision point. Monitoring these controls against established ranges and tracking values over time identifies assay problems. For simple qualitative assays, a positive and negative control should be run with each testing batch. This can be a commercial control or previously tested patient samples. Defined acceptability criteria must be attained and documented. For more complex qualitative assays such as leukemia and lymphoma immunophenotyping, a separate normal process control is not required. Most samples contain a component of normal cells providing data on the assay and reagent performance. Panels must be configured such that normal cells have distinct negative and positive controls. These internal controls can serve as positive and negative controls for each antibody. If internal controls are used, acceptability criteria must be established, results documented as well as corrective action documented if problems occur. Internal/Patient QC Many flow cytometry contain internal checks and balances that can be used as additional QC checks. For lymphocyte subset enumeration, the lympho-sum (CD3+NK+CD19) should account for all the gated lymphocytes in the sample and approach 100%. In addition, the T sum (CD4+ T
28 cells + CD8+ T cells) should approach the total CD3. In addition, duplicate markers run on the same patient should be equivalent (example replicate CD3). If using single platform technology (SPT) time should be constant when acquiring multiple tubes on the same patient. Using these internal/patient QC parameters can identify potential assay problems. The important aspects to note are that the laboratory is responsible for the design and effectiveness of the quality control program. All parameters being checked must have stated tolerance limits and all work must be reviewed periodically by the laboratory director.
29 Flow Cytometry Quality Assessment (QA) Quality assessment in flow cytometry ensures that the immediate and ultimate customers of the laboratory service (clinicians and patients), that the results are precise and clinically accurate. QA includes assay validation, document and change control of procedures, pre and post analytical sample handling such as specimen labeling and inadequate samples, and reporting turn around time. Laboratories should perform a detailed review of all these processes with the goals of incremental improvement and elimination of waste. Some examples of major components of quality assessment in clinical flow cytometry are as follows: Specimen collection/rejection criteria: Clinical information Sample preparation Specimen integrity verifications Data acquisition Data analysis Interpretation/reporting Training and ongoing competency Quality improvement Specimen collection/rejection criteria: Good laboratory practice states that the specimen containers be labeled at the point of collection. Samples must be submitted to the testing laboratory with a formal test request/order. In flow cytometry the date and time of collection is critical. The sample must be drawn in the appropriate anticoagulant with appropriate volume. Sample storage and shipping temperatures are also critical and can adversely affect results. The laboratory must document sample rejection criteria and act upon suboptimal sample receipt. Specimen collection errors can be tracked and monitored as a quality improvement. Clinical information Depending on the flow cytometry assay, clinical information is critical to accurate results. For enumeration of lymphocyte subsets and CD34 cells, this information may not be as critical as leukemia/lymphoma immunophenotyping. For the latter, clinical indication will provide the laboratory information on how to proceed with the procedure. Sample preparation Specimen integrity verifications Flow cytometry testing measures the presence of antigens on the surface of the viable cells. Accuracy depends on the viability of the sample received. In some applications, an assessment of the percent of viable cells will identify situations where the results are not accurate. In flow cytometry assays the ratio of cells of interest (antigen) and amount of antibody must be
30 optimized for best results and consistent for reproducibility. In many tests, the cell count of the patient sample is reviewed and adjusted (if needed) to optimize this ratio. Data acquisition In many flow cytometric assays, the number of acquired events must be robust enough for clinically relevant precision. This is generally defined by the assay quality requirements. For example, CD34 stem cell assays require a minimum of 100 cells of interest to assure an appropriate CV. For leukemia/lymphoma analysis, depending on the cell lineage of interest and required sensitivity the amount of acquired events may vary. Data analysis During the flow cytometric analysis step the gating technique is critical to identify the population of interest. Gating techniques are application specific and may require gating on light scatter or a combination of light scatter and fluorescence. Appropriate gating techniques can optimize the sensitivity of the assay. Data analysis in flow cytometry may require a qualitative assessment of the antigen expression (positive or negative) or a semi quantitative approach where the fluorescent intensity is assessed as compared to normal cell counterparts (dim or bright). Interpretation/reporting In quantitative flow cytometry assays clinicians are the ones that interpret the numerical value reported. This is the case for CD4 and CD34 measurements. In other applications such as leukemia/lymphoma immunophenotyping, a pathologist will interpret the case based on the qualitative pattern recognition of abnormal cells. This in conjunction with clinical indication and other laboratory results will ensure appropriate results. Training and ongoing competency All technical laboratory staff require adequate training on all job assignments. This training must be performed by a qualified trainer, with specific criteria for acceptability and sign off. Training verification is documented and approved by the supervisor and trainee. Any modifications or remedial problems require additional documented training. Ongoing competency assessment is verifying that the once trained, staff continue to perform the job assignment appropriately and meet objective minimum standards. Competency assessment must be performed and documented within the first six months and annually thereafter. Multiple modalities of assessment must be used ; direct observation, records review, blind testing and problem solving. Competency assessments must have objective criteria and be reviewed by the technical supervisor. Quality improvement
31 Quality improvement is a process in a clinical laboratory that measures the nonconformance s to procedures and identifies areas that need improvement. Example quality improvement metrics in flow cytometry may be turnaround time, sample handling errors, client complaints, delayed shipping, corrected or amended reports. Root cause analysis can identify potential causes and solutions. These must be documented and communicated to laboratory staff.
32 FORM FC-1 PAGE OF PROFICIENCY TESTING (PT) SURVEY LISTING & PARTICIIPATION SUMMARY FORM Institution: Survey Year: Department: PT Supplier: Suppliers Phone #: Instrument #: SURVEY NAME ANALYTE SHIPMENT DATES Reviewed by: Condition:
33 FORM FC-2 PROFICIENCY TESTING (PT) PROCESSING FORM ENROLLMENT AND TESTING OF SAMPLES: FLOW CYTOMETERY Institution: Department: PT Supplier Survey Year: Survey Name: Supplier Phone #: Received at Testing Site by: Results Due Time: Received in Acceptable Condition: Y: N: If Not, Action Taken: Signature Time: Results Acceptable: Yes: No: Score: Action Required (Form FC-3): Y: N: PT Sample Analyte(s) Result(s) Reported Correct Result(s) Reviewed by: Conditions: / / /
34 FORM FC-3 REMEDIAL ACTION FORM UNACCEPTABLE PROFICIENCY TESTING RESULTS FLOW CYTOMETRY Institution: Survey Year: PT Supplier: Department: Shipment Results Due Reasons for Unacceptable Results: Explanation of Incident: Remedial Action Taken: Results of Remedial Action Taken: Reviewed by: Conditions: / /
35 FORM FC-4 QUALITY ASSURANCE REVIEW FORM EVALUATION OF CORRECTIVE ACTIONS ON UNSATISFACTORY PROFICIENCY TESTING RESULTS Institution: Department: PT Supplier Survey Year: Survey Name: ACTION ACTION DATE OF PT SAMPLE REPORTED RESULT ACCEPTABLE RESULT TAKEN (Y/N) DOCUMENTED (Y/N) Reviewed by: Standard:
36 FORM FC-5A C YTOMETRY E QUIPMENT AND F UNCTION C HECKS F ORM I NSTRUMENT #: MONTH: YEAR: Beads Lot # Expiration Day of the Month Parameter Range Reviewed by: Standard:
37 FORM FC-5B L ABORATORY E QUIPMENT AND F UNCTION C HECKS F ORM M ONTH: Y EAR: Day of the Month Parameter Range Reviewed by: Standard:
38 FORM FC-5C Institution: Equipment: Procedure: Description of Problem: CORRECTIVE ACTION FORM PREVENTIVE MAINTENANCE AND FUNCTION CHECKS Department: Corrective Action Taken: Comments: Reviewed by: Standard:
39 FORM FC-5D EQUIPMENT SERVICE LOG DATE PROBLEM TECH DATE ACTION TAKEN TECH Reviewed by: Standard:
40 FORM FC-6 PIPETTE CALIBRATION FORM Institution: Department: Pipette #: Acceptable Range: Calibration Method: Gravimetric Balance Used: Evaporation Factor: Acceptable Results?: Y N Placed in Service?: Y Discarded C ALIBRATION R ESULTS # Replicates Calculations Mean= Mean Evap Factor = Accuracy = Mean Volume Ideal Volume x 100 = % Ideal Volume Reviewed by: U SE ADDITIONAL PAGES AS NEEDED Standards:
41 FORM FC-7 PAGE OF ADEQUACY OF METHODS/EQUIPMENT/INSTRUMENTS FOR TESTING Institution: Department: Method: Test: Cleared by FDA; Meets CLIA '88 Requirements for General QC: Y / N C HART OF P ARAMETERS Reportable Range Reference Range Specimen of Choice Precision Accuracy Analytical Sensitivity Analytical Specificity Interfering Substances Special Considerations Other Therapeutic Range Manufacturer's Technical Information Summary of Adequacy: Laboratory Data Reviewed by: Standard:
42 FORM FC-8 Q UALITY C ONTROL F ORM I NSTRUMENT: M ONTH: Y EAR: CD Control CD Control CD Control QC Lot/ Date Material Exp. Expected Expected Expected Tested Used Value Range Value Range Value Range Technician. Standard:
43 FORM FC-9 REMEDIAL ACTION FORM TEST RESULTS REPORTED IN ERROR Institition: Department: Patient Name: Patient ID: Accession #: Date Specimen Collected: Time Specimen Collected: Test: Incorrect Result: Corrected Result: Description of Incident: Person Notified of Incident: Notification Notification Time: By: Corrective Action Taken: Corrected Result Reported to: Method: Reviewed by: Time: Standard:
44 FORM FC-10 QUALITY ASSURANCE REVIEW CRITERIA FOR SPECIMEN COLLECTION AND HANDLING Institution: QA Review Month: Department: QA Review Year: TYPE OF REVIEW (CRITERIA FOR): ACTION TAKEN Patient Preparation Specimen Collection Labeling Preservation Transportation Dates for Data Collection: Shifts: All Number of Specimens Received: = 100 % Number of Specific Problems: = % Evaluation of Criteria: Problem Target % = < % Reviewed by: Standard:
45 FORM FC-11 Institution: QA Review Month: QUALITY ASSURANCE REVIEW FORM EVALUATION OF CRITERIA FOR SPECIMEN REJECTION Total # of Reviewed Specimens: Department: QA Review Year: Total # Unacceptable Specimens: % Unacceptable Specimens: Unacceptable Specimen Target: % DATE PATIENT ID REASON FOR UNACCEPTABILITY SAMPLE TESTED (Y/N) USER NOTIFIED (Y/N) Evaluation of Effectiveness: Reviewed by: Standard:
46 FORM FC-12 QUALITY ASSURANCE REVIEW FORM COMPLETENESS OF INFORMATION ON REQUISITIONS AND REPORTS Institution: QA Review Month: Department: QA Review Year: R EQUISITION R EPORT F ORM TYPE OF REVIEW ACTION TAKEN TYPE OF REVIEW ACTION TAKEN Patient Name Patient Name Location Location I.D. # I.D. # Ordering Physician Ordering Physician Test Ordered Test Ordered Normal Range Interpretation Lab Med. Director Dates for Data Collection: Shifts: All Number of Requisitions or Reports Reviewed: = 100% Number of Missing Items under Review: = % Incompleteness Evaluation of Completeness: Incompleteness Target % = < % Reviewed by: Standard:
47 FORM FC-13 QUALITY ASSURANCE REVIEW FORM QUALITY ASSURANCE FOR QUALITY CONTROL CORRECTIVE ACTIONS Institution: QA Review Month: Department: QA Review Year: TYPE OF REVIEW ACTION TAKEN Problems identified during the evaluation of calibration and control data for each test method Problems identified during the evaluation of patient test values for the purpose of verifying the reference range of a test method Errors detected in reported results Other: Problem/Error Target % = < % Total # Reviewed: # of Problems/Errors: % of Problems/Errors: % Evaluation of Effectiveness: Reviewed by: Standard:
48 FORM FC-14 QUALITY ASSURANCE REVIEW FORM RELATIONSHIP BETWEEN TEST RESULTS USING DIFFERENT METHODS, INSTRUMENTS OR TESTING SITES Institution: Department: Test System #1: Test System #2: Test Site: Methodology: Instrument: Identification Number: Normal Range: Test Site: Methodology: Instrument: Identification number: Normal Range: For Quantitative Assays: Obtained Correlation Coefficient = Acceptable Correlation Coefficient = > Acceptable Delta = Date Sample # Test System # 1 Test System # 2 Delta Acceptable Y/N Tester Evaluation of Relationship: U SE ADDITIONAL PAGES AS NEEDED Reviewed by: Standard:
49 FORM FC-15 QUALITY ASSESSMENT REVIEW FORM EVALUATION OF PATIENT TEST RESULTS INCONSISTENT WITH PATIENT CRITERIA Institution: Department: Total # of Results Reviewed: # of Inconsistent Results Evaluated: % Inconsistent Results Evaluated: Target % Evaluation: RESULTS INCONSISTENT WITH: DATE # OF RESULTS SHIFT OTHER TESTS RESULT DISTRIBUTION DIAGNOSIS AGE SEX Evaluation of Inconsistencies: Reviewed by: Standard:
50 FORM FC-16 SEE ATTACHED SHEET(S) QUALITY ASSESSMENT REVIEW FORM EMPLOYEE QUALIFICATION DOCUMENTATION Institution: Department: EMPLOYEE NAME POSITION DATE HIRED QUALIFICATION ROUTE AS DESCRIBED IN Director Technical Supervisor Clinical Consultant General Supervisor Testing Personnel Note: The same individual may serve several roles in the laboratory, if qualified. Copies of all degrees and certification, if applicable, are attached to this form. Reviewed by: Standard:
51 FORM FC-17 PAGE OF QUALITY ASSESSMENT REVIEW FORM EMPLOYEE COMPETENCE REVIEW-FLOW CYTOMETRY Institution: Department: EMPLOYEE NAME TECHNICAL SUPERVISOR COMPETENCY VALIDATION METHOD A. Direct Observation of Routine Testing B. MONITORING TEST RESULTS C. REVIEW OF WORKSHEETS, QC, ETC. D. DIRECT OBSERVATION OF INSTRUMENT MAINTENANCE E. TESTING OF BLIND SAMPLES OR PROFICIENCY TESTS F. ASSESSMENT OF PROBLEM SOLVING ABILITY Reviewed by: Condition:
52 FORM FC-18 FORM OF SEE DOCUMENTATION ATTACHED QUALITY ASSESSMENT REVIEW FORM DOCUMENTATION OF COMPLAINTS AND PROBLEMS REPORTED TO LABORATORY Institution: Review Month: Department: Review Year: R EASON FOR C OMPLAINT/INCIDENT R EPORT Explanation of Incident: ( Time: ) Corrective Action Taken: Results of Corrective Action Taken: Reviewed by: Standard:
53 FORM FC-19 QUALITY ASSESSMENT REVIEW FORM QUALITY ASSESSMENT REVIEW WITH STAFF Institution: Staff Members Present/Contacted: Department: Problems Identified in QA Reports: Corrective Action Taken: Results of Corrective Action Taken: Reviewed by: Standard:
Laboratory Director Responsibilities
Clinical Laboratory Improvement Amendments (CLIA) Laboratory Director Responsibilities What Are My Responsibilities As A Laboratory Director NOTE: Congress passed the Clinical Laboratory Improvement Amendments
2010 Laboratory Accreditation Program Audioconference. Accreditation Requirements for Waived Vs. Non-waived Tests
2010 Laboratory Accreditation Program Audioconference Accreditation Requirements for Waived Vs. Non-waived Tests Objectives: After participating in this audioconference you will be able to: Define the
Standards for Laboratory Accreditation
Standards for Laboratory Accreditation 2013 Edition cap.org Laboratory Accreditation Program Standards for Accreditation 2013 Edition Preamble Pathology is a medical specialty essential to patient care
Document Review: Centers for Medicare and Medical Service (CMS) What Do I Need to Do to Assess Personnel Competency?
Document Review: Centers for Medicare and Medical Service (CMS) What Do I Need to Do to Assess Personnel Competency? http://www.cms.gov/regulations-and-guidance/legislation/clia/downloads/clia_compbrochure_508.pdf
JOINT COMMISSION INTERNATIONAL ACCREDITATION STANDARDS FOR. 2nd Edition
JOINT COMMISSION INTERNATIONAL ACCREDITATION STANDARDS FOR CliniCAl laboratories 2nd Edition Effective 1 April 2010 International Patient Safety Goals (IPSG) Goals The following is a list of all goals.
Prepublication Requirements
Issued Prepublication Requirements The Joint Commission has approved the following revisions for prepublication. While revised requirements are published in the semiannual updates to the print manuals
Individualized Quality Control Plan
NOVEMBER 2014 CLIA Individualized Quality Control Plan WHAT IS AN IQCP? OVERVIEW Discovering, Deciphering and Designing an Individualized Quality Control Plan (IQCP) IQCP provides a framework for customizing
CAP Point of Care Checklist Frequently Asked Questions Roger D. Klein, MD Sheldon Campbell, MD, PhD Peter J. Howanitz, MD
CAP Point of Care Checklist Frequently Asked Questions Roger D. Klein, MD Sheldon Campbell, MD, PhD Peter J. Howanitz, MD TABLE OF CONTENTS Introduction Applicability General Topics Proficiency Testing
Center for Clinical Standards and Quality/Survey & Certification Group
DEPARTMENT OF HEALTH & HUMAN SERVICES Centers for Medicare & Medicaid Services 7500 Security Boulevard, Mail Stop C2-21-16 Baltimore, Maryland 21244-1850 Center for Clinical Standards and Quality/Survey
Checklist. Standard for Medical Laboratory
Checklist Standard for Medical Laboratory Name of hospital..name of Laboratory..... Name. Position / Title...... DD/MM/YY.Revision... 1. Organization and Management 1. Laboratory shall have the organizational
NC SBI QUALITY ASSURANCE PROGRAM
NC SBI QUALITY ASSURANCE PROGRAM for the SBI Reviewed by: Deputy Assistant Director Bill Weis Date: Approved by: Assistant Director Jerry Richardson Date: Originating Unit: SBI Effective Date: July 25,
Clinical Laboratory Improvement Amendments (CLIA) How to Obtain a CLIA Certificate
Clinical Laboratory Improvement Amendments (CLIA) How to Obtain a CLIA Certificate When is a CLIA Certificate Required? NOTE: Congress passed the Clinical Laboratory Improvement Amendments (CLIA) in 1988
How to Verify Performance Specifications
How to Verify Performance Specifications VERIFICATION OF PERFORMANCE SPECIFICATIONS In 2003, the Centers for Medicare and Medicaid Services (CMS) updated the CLIA 88 regulations. As a result of the updated
Using and Maintaining Documents and Records. Finding the information when you need it
Using and Maintaining Documents and Records Finding the information when you need it Problem Scenario You are the laboratory supervisor in a moderate-sized hospital. A physician calls you and says that
Clinical Laboratory Improvement Amendments (CLIA) How to Obtain a CLIA Certificate of Waiver
Clinical Laboratory Improvement Amendments (CLIA) How to Obtain a CLIA Certificate of Waiver When is a CLIA Certificate of Waiver Required? NOTE: Congress passed the Clinical Laboratory Improvement Amendments
Gap Analysis of ISO 15189:2012 and ISO 15189:2007 in the field of Medical Testing
Gap Analysis May 2013 Issued: May 2013 Gap Analysis of and in the field of Medical Testing Copyright National Association of Testing Authorities, Australia 2013 This publication is protected by copyright
Quality Assurance Guidelines for Laboratories Performing Microbial Forensic Work
for Laboratories Performing Microbial Forensic Work Produced by the Members of the Scientific Working Group on Microbial Genetics and Forensics (SWGMGF) Contact: Bruce Budowle, Chair, FBI Laboratory, 2501
Department of Defense INSTRUCTION
Department of Defense INSTRUCTION NUMBER 6440.02 May 29, 2014 USD(P&R) SUBJECT: Clinical Laboratory Improvement Program (CLIP) References: See Enclosure 1 1. PURPOSE. This instruction: a. Reissues DoD
AOAC Research Institute PERFORMANCE TESTED METHODS SM PROGRAM. POLICIES and PROCEDURES
AOAC Research Institute PERFORMANCE TESTED METHODS SM PROGRAM POLICIES and PROCEDURES Notice: AOAC Research Institute reserves the right to modify the program at any time. Participants are required to
Examples: collecting the right sample on the right patient; labeling the sample accurately;
Quality Assessment: Basics & EMR is called by several names: and are just two of them. Quality Assessment (QA) is an on-going program designed to monitor and evaluate the quality or accuracy of all laboratory
Competency Assessment (both of employees and of the laboratory as a whole)
Competency Assessment (both of employees and of the laboratory as a whole) I. Purpose: A. The CLIA'88 legislation requires a mechanism to evaluate and demonstrate competency in test performance for each
CHAPTER 7 QUALITY ASSESSMENT
CHAPTER 7 QUALITY ASSESSMENT Chapter 7 QUALITY ASSESSMENT 7.1 OVERVIEW OF CBB-SPECIFIC QUALITY ASSURANCE/QUALITY CONTROL PROGRAM An extensive, site-specific Quality Assurance/Quality Control (QA/QC) program
Subpart H--Participation in Proficiency Testing for Laboratories Performing Nonwaived Testing
Subpart H--Participation in Proficiency Testing for Laboratories Performing Nonwaived Testing Subpart H - Guidelines - General By law, proficiency testing (PT) programs are evaluated initially for CMS
Subpart B--Conditions of Participation: Comprehensive Outpatient Rehabilitation Facilities
(Revised as of January 1, 2003) Subpart B--Conditions of Participation: Comprehensive Outpatient Rehabilitation Facilities 485.50 Basis and scope. This subpart sets forth the conditions that facilities
Surgi Manufacturing Quality Manual
Surgi Manufacturing Page 1 of 18 Approvals: QA: Eng. Mgt. : A Date: 18Aug98 1. Introduction... 4 1.1 Scope... 4 1.2 Purpose... 4 1.3 Authority... 4 1.4 Issue of the Manual... 4 1.5 Amendments... 4 1.6
Calibration & Preventative Maintenance. Sally Wolfgang Manager, Quality Operations Merck & Co., Inc.
Calibration & Preventative Maintenance Sally Wolfgang Manager, Quality Operations Merck & Co., Inc. Calibration: A comparison of two instruments or measuring devices one of which is a standard of known
ISO/IEC 17025 QUALITY MANUAL
1800 NW 169 th Pl, Beaverton, OR 97006 Revision F Date: 9/18/06 PAGE 1 OF 18 TABLE OF CONTENTS Quality Manual Section Applicable ISO/IEC 17025:2005 clause(s) Page Quality Policy 4.2.2 3 Introduction 4
Guidance on IRB Continuing Review of Research
NOTE: THIS GUIDANCE SUPERSEDES OHRP S JANUARY 15, 2007 GUIDANCE ENTITILED GUIDANCE ON CONTINUING REVIEW. CLICK HERE FOR THE JANUARY 15, 2007 GUIDANCE. Office for Human Research Protections Department of
Laboratory Accreditation. Personnel Qualifications. What s New? March 17, 2010
Laboratory Accreditation Personnel-ly Speaking. Qualifications and Competency 2009. College of American Pathologists (CAP). All rights are reserved. Participants are permitted to duplicate the materials
UCLA PATHOLOGY & LABORATORY MEDICINE QUALITY MANAGEMENT PLAN
Page 1 of 11 UCLA PATHOLOGY & LABORATORY MEDICINE QUALITY MANAGEMENT PLAN INTRODUCTION A quality management system can be described as a set of key quality elements that must be in place for an organization
Investigational Drugs: Investigational Drugs and Biologics
: I. PURPOSE The purpose of this policy is to establish procedures for the proper control, storage, use and handling of investigational drugs and biologics to ensure that adequate safeguards are in place
Comparison Chart of FDA and EPA Good Laboratory Practice (GLP) Regulations and the OECD Principles of GLP
Comparison Chart of FDA and EPA Good Laboratory Practice (GLP) Regulations and the OECD Principles of GLP Document issued on: June 2004 U.S. Department of Health and Human Services Food and Drug Administration
ASSURING THE QUALITY OF TEST RESULTS
Page 1 of 12 Sections Included in this Document and Change History 1. Purpose 2. Scope 3. Responsibilities 4. Background 5. References 6. Procedure/(6. B changed Division of Field Science and DFS to Office
General Information. Our Background Automated Phone Services Holiday Coverage Licenses & Accreditations
General Information Our Background Automated Phone Services Holiday Coverage Licenses & Accreditations Our Background Foundation Laboratory is an advanced, accredited and certified clinical diagnostic
GENERAL OPERATIONS MANUAL FOR ASTM PRODUCT CERTIFICATION PROGRAM
GENERAL OPERATIONS MANUAL FOR ASTM PRODUCT CERTIFICATION PROGRAM INTERNATIONAL Standards Worldwide Issued September 25, 2012 Version 5.0 BY AMERICAN SOCIETY FOR TESTING AND MATERIALS INTERNATIONAL ASTM
105 CMR: DEPARTMENT OF PUBLIC HEALTH 105 CMR 210.000: THE ADMINISTRATION OF PRESCRIPTION MEDICATIONS IN PUBLIC AND PRIVATE SCHOOLS
105 CMR 210.000: THE ADMINISTRATION OF PRESCRIPTION MEDICATIONS IN PUBLIC AND PRIVATE SCHOOLS Section 210.001: Purpose 210.002: Definitions 210.003: Policies Governing the Administration of Prescription
Calibration Verification
Calibration Verification INTRODUCTION On January 24, 2003, the Centers for Medicare and Medicaid Services (CMS) published updated laboratory regulations that became effective April 24, 2003. Included in
Quality Assurance QUALITY ASSURANCE PLAN
Revision 2 Page 1 of 40 QUALITY ASSURANCE PLAN PLAN APPROVALS: Jeff Shouse Signature on File DIRECTOR OF QUALITY ASSURANCE DIRECTOR OF QUALITY ASSURANCE (signature) DATE Rodney Baltzer Signature on File
Document and Record Control in a Hospital Clinical Laboratory
Document and Record Control in a Hospital Clinical Laboratory Linda A. Chambers, MD Transfusion Service Medical Director Riverside Methodist Hospital and Grant Medical Center OhioHealth, Columbus, Ohio,
Best Practices for Maintaining Quality in Molecular Diagnostics Gyorgy Abel, MD, PhD
Best Practices for Maintaining Quality in Molecular Diagnostics Gyorgy Abel, MD, PhD Director, Clinical Chemistry Molecular Diagnostics / Immunology Department of Laboratory Medicine Lahey Clinic Medical
Urinalysis Compliance Tools. POCC Webinar January 19, 2011 Dr. Susan Selgren
Urinalysis Compliance Tools POCC Webinar January 19, 2011 Dr. Susan Selgren Learning Objectives Be able to review and improve upon a laboratory plan for compliance including: Competency Documentation Proficiency
LAP Audioconference How to Prepare and Comply with Your Quality Management Plan* February 18, 2009
LAP Audioconference How to Prepare and Comply with Your Quality Management Plan* February 18, 2009 Paul Bachner, MD, FCAP Professor & Chair Department of Pathology & Laboratory Medicine University of Kentucky
2009 LAP Audioconference Series. How to Prepare and Comply with Your Quality Management Plan
2009 LAP Audioconference Series How to Prepare and Comply with Your Quality Management Objectives: As a result of participating in this session, you will be able to: Explain the reasons why the QM is important
NABL NATIONAL ACCREDITATION
NABL 160 NABL NATIONAL ACCREDITATION BOARD FOR TESTING AND CALIBRATION LABORATORIES GUIDE for PREPARING A QUALITY MANUAL ISSUE NO. : 05 AMENDMENT NO : 00 ISSUE DATE: 27.06.2012 AMENDMENT DATE: -- Amendment
ALABAMA BOARD OF MEDICAL EXAMINERS ADMINISTRATIVE CODE CHAPTER 540-X-8 ADVANCED PRACTICE NURSES: COLLABORATIVE PRACTICE TABLE OF CONTENTS
Medical Examiners Chapter 540-X-8 ALABAMA BOARD OF MEDICAL EXAMINERS ADMINISTRATIVE CODE CHAPTER 540-X-8 ADVANCED PRACTICE NURSES: COLLABORATIVE PRACTICE TABLE OF CONTENTS 540-X-8-.01 540-X-8-.02 540-X-8-.03
Specialties Manufacturing. Talladega Castings & Machine Co., Inc. ISO 9001:2008. Quality Manual
Specialties Manufacturing Talladega Castings & Machine Co., Inc. ISO 9001:2008 This document is the property of TMS and may not be reproduced, wholly, or in part, without the express consent of TMS. Rev.
Sutter Health Support Services Shared Laboratory Position Description. Incumbent: Laboratory Date: October 23, 2006 Written By: Michele Leonard
Sutter Health Support Services Shared Laboratory Position Description Position Title: Clinical Laboratory Scientist, Microbiologist Incumbent: Entity: SHSS Shared Laboratory Reports To: Director of Operations,
New York State Department of Health Clinical Laboratory Reference System. Guide to Program Requirements and Services
New York State Department of Health Clinical Laboratory Reference System Guide to Program Requirements and Services Application Procedures Personnel Requirements Laboratory Surveys Proficiency Testing
Content Sheet 3-1: Equipment Management Overview
Content Sheet 3-1: Equipment Management Overview Role in quality management system Equipment management is one of the essential elements of a quality management system. Proper management of the equipment
IAC 7/2/08 Nursing Board[655] Ch 5, p.1. CHAPTER 5 CONTINUING EDUCATION [Prior to 8/26/87, Nursing Board[590] Ch 5]
IAC 7/2/08 Nursing Board[655] Ch 5, p.1 CHAPTER 5 CONTINUING EDUCATION [Prior to 8/26/87, Nursing Board[590] Ch 5] 655 5.1(152) Definitions. Approved provider means those persons, organizations, or institutions
CHECKLIST ISO/IEC 17021:2011 Conformity Assessment Requirements for Bodies Providing Audit and Certification of Management Systems
Date(s) of Evaluation: CHECKLIST ISO/IEC 17021:2011 Conformity Assessment Requirements for Bodies Providing Audit and Certification of Management Systems Assessor(s) & Observer(s): Organization: Area/Field
Company Quality Manual Document No. QM Rev 0. 0 John Rickey Initial Release. Controlled Copy Stamp. authorized signature
Far West Technology, Inc. ISO 9001 Quality Manual Document No.: QM Revision: 0 Issue Date: 27 August 1997 Approval Signatures President/CEO Executive Vice President Vice President/CFO Change Record Rev
Development and Validation of In Vitro Diagnostic Tests. YC Lee, Ph.D. CEO
Development and Validation of In Vitro Diagnostic Tests YC Lee, Ph.D. CEO 1 Validation of In Vitro Diagnostic Tests Validated d Diagnostic Test should: Provides test results that identify if positive i
EQR PROTOCOL 1: ASSESSMENT OF COMPLIANCE WITH MEDICAID MANAGED CARE REGULATIONS
OMB Approval No. 0938-0786 EQR PROTOCOL 1: ASSESSMENT OF COMPLIANCE WITH MEDICAID MANAGED CARE REGULATIONS A Mandatory Protocol for External Quality Review (EQR) Protocol 1: Protocol 2: Validation of Measures
General. What is a laboratory test? What is a waived test?
General What is a laboratory test? What is a waived test? Laboratory tests are medical procedures that involve testing samples of blood, urine, or other tissues or substances from the body. Information
US EPA REGION III QUALITY MANAGEMENT PLAN REVIEW CHECKLIST
US EPA REGION III Organization: EPA Organization: EPA Program: Contact: EPA Contact: EPA Contract/Grant/IAG Number: Phone Number: Phone Number: Reviewer: Date Reviewed: Reviewer Organization: Check New
Transfusion Medicine: Checklists and Challenges
SEABB Annual Meeting 2014 Transfusion Medicine: Checklists and Challenges Denise Driscoll, MS, MT(ASCP)SBB Director, Accreditation and Regulatory Affairs March 19, 2014 cap.org v. # Transfusion Medicine:
Title 10 DEPARTMENT OF HEALTH AND MENTAL HYGIENE
Title 10 DEPARTMENT OF HEALTH AND MENTAL HYGIENE Subtitle 09 MEDICAL CARE PROGRAMS Chapter 61 Medical Day Care Services Waiver Authority: Health-General Article, 2-104(b), 15-103, and 15-111, Annotated
Quality Control of the Future: Risk Management and Individual Quality Control Plans (IQCPs)
Quality Control of the Future: Risk Management and Individual Quality Control Plans (IQCPs) James H. Nichols, PhD, DABCC, FACB Professor of Pathology, Microbiology, and Immunology Medical Director, Clinical
RECOMMENDATION ON THE CONTENT OF THE TRIAL MASTER FILE AND ARCHIVING
RECOMMENDATION ON THE CONTENT OF THE TRIAL MASTER FILE AND ARCHIVING July 2006 TABLE OF CONTENTS Page 1. Introduction 2 2. Scope 2 3. Documents to be archived 2 4. Quality of essential documents 10 5.
Procedure 5202P Personnel
FEDERAL HIGHWAY ADMINISTRATION MANDATED DRUG AND ALOCHOL TESTING PROGRAM Definitions: Accident, for purposes of this policy, is as an incident involving an employee whose job responsibilities require a
Procedure for Procurement and Receipt
Procedure for Procurement and Receipt 1.0 Purpose - To ensure that all supplies, equipment and services purchased by the State Crime Laboratory (Laboratory) are properly procured and received. 2.0 Scope
ALABAMA BOARD OF NURSING ADMINISTRATIVE CODE CHAPTER 610-X-5 ADVANCED PRACTICE NURSING COLLABORATIVE PRACTICE TABLE OF CONTENTS
ALABAMA BOARD OF NURSING ADMINISTRATIVE CODE CHAPTER 610-X-5 ADVANCED PRACTICE NURSING COLLABORATIVE PRACTICE TABLE OF CONTENTS 610-X-5-.01 610-X-5-.02 610-X-5-.03 610-X-5-.04 610-X-5-.05 610-X-5-.06 610-X-5-.07
Magellan Behavioral Care of Iowa, Inc. Provider Handbook Supplement for Iowa Autism Support Program (ASP)
Magellan Behavioral Care of Iowa, Inc. Provider Handbook Supplement for Iowa Autism Support Program (ASP) 2014 Magellan Health Services Table of Contents SECTION 1: INTRODUCTION... 3 Welcome... 3 Covered
Center for Medicaid and State Operations/Survey and Certification Group
DEPARTMENT OF HEALTH & HUMAN SERVICES Centers for Medicare & Medicaid Services 7500 Security Boulevard, Mail Stop S2-12-25 Baltimore, Maryland 21244-1850 Center for Medicaid and State Operations/Survey
MEAT GRADING AND CERTIFICATION BRANCH QUALITY MANUAL
United States Department of Agriculture Marketing and Regulatory Programs Agricultural Marketing Service Livestock and Seed Program Meat Grading & Certification Branch MGC Instruction 800 May 9, 2005 Page
CREDENTIALING PROCEDURES MANUAL
CREDENTIALING PROCEDURES MANUAL Page PART I Appointment Procedures 1 PART II Reappointment Procedures 5 PART III Delineation of Clinical Privileges Procedures 7 PART IV Leave of Absence, Reinstatement,
NIST HANDBOOK 150-5 CHECKLIST CONSTRUCTION MATERIALS TESTING
NIST HANDBOOK 150-5 CHECKLIST CONSTRUCTION MATERIALS TESTING Instructions to the Assessor: This checklist addresses specific accreditation criteria prescribed in NIST Handbook 150-5, Construction Materials
NEW JERSEY ADMINISTRATIVE CODE TITLE 8, CHAPTER 7 LICENSURE OF PERSONS FOR PUBLIC HEALTH POSITIONS. Authority. N.J.S.A. 26:1A-38 et seq.
NEW JERSEY ADMINISTRATIVE CODE TITLE 8, CHAPTER 7 LICENSURE OF PERSONS FOR PUBLIC HEALTH POSITIONS Authority N.J.S.A. 26:1A-38 et seq. Amendments in bold adopted December 7, 1998 SUBCHAPTER 1. GENERAL
Quality Assurance Manual for Low Level Radioactive. Waste Disposal Facility
WM 07 Conference, February 25 March 1 2007, Tucson, AZ Quality Assurance Manual for Low Level Radioactive Waste Disposal Facility Yasser T. Mohamed Hot Laboratories and Waste Management Center, Egyptian
ENVIRONMENTAL, HEALTH AND SAFETY PERSONNEL MANAGEMENT LEVELING GUIDE
ENVIRONMENTAL, HEALTH AND SAFETY PERSONNEL MANAGEMENT LEVELING GUIDE Levels Job Codes Scope of Position Top Environmental Affairs Executive (Corporate) 1000 The most senior Environmental, Health and Safety
NIH POLICY MANUAL. 1340 - NIH Occupational Safety and Health Management Issuing Office: ORS/DOHS 301-496-2960 Release Date: 2/27/06
NIH POLICY MANUAL 1340 - NIH Occupational Safety and Health Management Issuing Office: ORS/DOHS 301-496-2960 Release Date: 2/27/06 1. Explanation of Material Transmitted: This chapter establishes the scope
BCBSM MENTAL HEALTH AND SUBSTANCE ABUSE MANAGED CARE PROGRAM
BCBSM MENTAL HEALTH AND SUBSTANCE ABUSE MANAGED CARE PROGRAM Professional Provider Participation Agreement This agreement (Agreement) is between Blue Cross Blue Shield of Michigan (BCBSM), and the provider
New Investigator Collaborations and Interactions: Regulatory
Your Health and Safety... Our priority Votre santé et votre Securité notre priorité New Investigator Collaborations and Interactions: Regulatory NCIC Clinical Trials Group New Investigator Clinical Trials
UL Qualified Firestop Contractor Program Requirements April 2012
UL Qualified Firestop Contractor Program Requirements April 2012 For more information, please contact your local UL Field Representative INTRODUCTION: In order for a firestop systems installer/contractor
OPERATIONAL STANDARD
1 of 11 1. Introduction The International Safe Transit Association (ISTA), a non-profit association whose objective is to prevent product damage and excess packaging usage within the distribution environment.
CAPABILITY 12: Public Health Laboratory Testing
Public health laboratory testing is the ability to conduct rapid and conventional detection, characterization, confirmatory testing, data reporting, investigative support, and laboratory networking to
RULES AND REGULATIONS FOR HOME HEALTH CARE AGENCIES
RULES AND REGULATIONS FOR HOME HEALTH CARE AGENCIES 28 Pa. Code, Part IV, Health Facilities Subpart F. Chapter 601 and Subpart A. Chapter 51 NOTICE OF CHANGE On December 18, 1992, the Pennsylvania Health
Example of a food company quality
Appendix A manual Example of a food company quality Contents Date: 13/03/95 RME-QLMN-OO Page 1 of 3 Section Title ISO 9001 reference 01 In trod uction 02 Purpose 03 Scope 04 Definitions 05 Management responsibility
CLIA Required Personnel Qualifications
CLIA Required Personnel Qualifications Stacy Olea, FACHE, MT(ASCP) Field Director Surveyor Management and Development 2012 ANNUAL EDUCATION CONFERENCE Lab Central Connect 1 Disclaimer This presentation
Ch. 601 HOME HEALTH CARE AGENCIES 28. Subpart G. HOME HEALTH CARE AGENCIES 601. HOME HEALTH CARE AGENCIES... 601.1
Ch. 601 HOME HEALTH CARE AGENCIES 28 Subpart G. HOME HEALTH CARE AGENCIES Chap. Sec. 601. HOME HEALTH CARE AGENCIES... 601.1 Authority The provisions of this Subpart G issued under Chapter 8 of the Health
Guide for the Evaluation of Program Specialist Positions
Guide for the Evaluation of Program Specialist Positions Table of Contents COVERAGE OF THE GUIDE... 2 TITLING PRACTICES... 3 BACKGROUND INFORMATION... 3 CRITERIA USED FOR GRADE-LEVEL DISTINCTION... 5 NOTES
The purpose of this Supplier Quality Standard is to communicate the expectations and requirements of Baxter Healthcare Corporation to its suppliers.
Supplier Quality Standard 1.0 Purpose The purpose of this Supplier Quality Standard is to communicate the expectations and requirements of Baxter Healthcare Corporation to its suppliers. These expectations
QUALITY ASSURANCE MANUAL JPM OF MISSISSIPPI, INC.
QUALITY ASSURANCE MANUAL JPM OF MISSISSIPPI, INC. Hattiesburg, MS Revision E 01/19/11 Revised to ISO 9001:2008 on July 9, 2009 JPM OF MISSISSIPPI, INC. MANAGEMENT QUALITY POLICY It is the goal of JPM of
RULES AND REGULATIONS FOR LICENSING APPLIED BEHAVIOR ANALYSTS AND APPLIED BEHAVIOR ASSISTANT ANALYSTS
RULES AND REGULATIONS FOR LICENSING APPLIED BEHAVIOR ANALYSTS AND APPLIED BEHAVIOR ASSISTANT ANALYSTS [R5-86-ABA] STATE OF RHODE ISLAND AND PROVIDENCE PLANTATIONS DEPARTMENT OF HEALTH October 2015 INTRODUCTION
Provider Monitoring Process
Provider Monitoring Process This statewide provider monitoring process is applicable for all providers including direct vendors and Organized Health Care Delivery Systems (OHCDS) qualified to provide Consolidated
EPA NATIONAL LEAD LABORATORY ACCREDITATION PROGRAM. LABORATORY QUALITY SYSTEM REQUIREMENTS (LQSR) REVISION 3.0 (November 05, 2007)
EPA NATIONAL LEAD LABORATORY ACCREDITATION PROGRAM LABORATORY QUALITY SYSTEM REQUIREMENTS (LQSR) REVISION 3.0 (November 05, 2007) The requirements in this document apply to all lead testing laboratories
DEC STD 017-2 - ISO 9002 - Quality Systems - Model for Quality Assurance in Production and Installation
Digital Internal Use Only DEC STD 017-2 - ISO 9002 - Quality Systems - Model for Quality Assurance in Production and Installation DOCUMENT IDENTIFIER: A-DS-EL00017-02-0000 Rev A, ABSTRACT: This standard
Content Sheet 16-1: Introduction to Documents & Records
Content Sheet 16-1: Introduction to Documents & Records Role in quality management system The management of documents and records is one of the 12 essential elements of the quality system. The management
THERMAL INSULATION MATERIALS
NIST HANDBOOK 150-15 2006 Edition National Voluntary Laboratory Accreditation Program THERMAL INSULATION MATERIALS Lawrence I. Knab National Voluntary Laboratory Accreditation Program Standards Services
Product Liability Risk Control Checklist
Product Liability Risk Control Checklist Appendix C1 This material will help you evaluate your products liability exposure. It is designed to enable you to focus on areas that need to be addressed to safeguard
Quality Management System Policy Manual
Quality Management System Burns Engineering, Inc. 10201 Bren Road East Minnetonka, MN 55343 4. 4.1 General Requirements The Quality Manual consists of the quality system policy documents and the quality
AMERICAN POLYGRAPH ASSOCIATION EDUCATION ACCREDITATION COMMITTEE
AMERICAN POLYGRAPH ASSOCIATION EDUCATION ACCREDITATION COMMITTEE ACCREDITATION STANDARDS Version 2.02 (Effective January 1, 2015) 1 Table of Contents 1.0 INTRODUCTION 3 1.1 Mission 3 1.2 History 3 1.3